1. Registration User PIN code or Key Cards in EZ Mode a Repeat operation using settings indicated LOCKUDOD ASSA ABLOY Keypad Programming EZ Mode To Program Keypad with Pin code Press Registration Button R nb Enter desired user PIN code GN nd Re press Registration Button GJ roy After removing the battery cover You now have 20 seconds to enter Re press the Registration button press the Registration button you your 4 12 digit user PIN code you will hear another confirmation will hear a confirmation tone tone Now watch the keypad and your code will briefly appear U R 4 PIN User PIN code Registration R Complete To Program Keypad with Key Card After removing the battery cover You now have 20 seconds to present Re press the Registration button press the Registration button you card to lock wait for beep and if you will hear another confirmation will hear a confirmation tone you require additional cards tone repeat up to 20 Cards eaj 4 R Complete R 1 g Key Card Registration ir ID ASSA ABLOY Keypad Functions EZ Mode User PIN Code Key Card registration R U PIN User PIN Code Registration R Complete I U User Key Card Registration C R Complete User PIN Code Key Card Function 1 Touch screen with hand or fingers to activate 2 Enter 4 12 digit User PIN code followed by the
2. Status LED Located on inside escutcheon indicated red when powered up CID ASSA ABLOY EZ Mode Functions Factory Defaults A Settings Factory Defaults Default Mode EZ Mode User PIN Code 1234567890 0 Passage Disable To set EZ Mode slide Visitor Code Nan switch to EZ followed by the soft rest Volume High Relock time 5 sec Wrong code entry limit 5 times Shut down time 180 sec e EZ mode allows for a single User PIN Code to be assigned Up to 20 Key Cards can be programmed into the 001 Touch in this mode e With the use of the User PIN Code a number of basic functions outline on page 10 can be accessed e A User PIN Code between 4 to 12 digits can be entered For programming new User PIN Code in EZ mode refer to the next page These values cannot be changed Programming Features Menu amp Icons Touch the screen with palm of hand or fingers to begin and end actions Click the indicated number Enter User PIN code Can be 4 to 12 digits in length Factory default 1234567890 E lt 088 Enter Visitor PIN Can be 4 12 digits in length E Press the key on the touchscreen to Siena Enter user Key Card s Up to 20 cards Press the key on the touchscreen to Enter or Accept entry Time setting in Visitor mode Can be 3 336 Hours
3. Latch Knob Handle Lock Case Operation Lamp Registration Button Battery Pack Cover Lock functions explained in Product Definitions refer page 7 Note The Battery Pack assembly is only for internal applications ID ASSA ABLOY Ouick Guide Keypad Programming 001TOUCH Quick Programming Guide Note This quick guide is for EZ Mode only for Advanced Mode please refer to page 11 To Program Keypad with User Pin Code r desired user PIN code GN nb Re press Registration Button R Q Mein User Pin Code Registration 4 R Complete To Program Keypad with Key Card Note Always ensure you test the User PIN code and Key Card with the door open to ensure the lock code or Key Card is working CHD ASSA ABLOY Quick Guide Keypad Operation 001TOUCH Quick User Guide Note This quick guide is for EZ Mode only for Advanced Mode please refer to page 11 To Open Door with User PIN Code Touch lock with palm of hand or fingers to activate Contact Key Card Quick Notes Programming the card key will not effect the user PIN code Programming the user PIN code will not effect the card key e Ifyou want to delete the user PIN code simply program your new user PIN code and the old code will be deleted automatically In order to remove one or more key cards programmed to the lock simply reprogram all the key card s
4. of 6 digits and is only required when in advanced mode The Master code has the ability to add and delete users Key Card Is a unigue card that can be used like a key The Key Card can be reused as many times as you want The Key Card can be used as a backup if you forget your pin code or used instead of your pin To use the Key Card present it near the centre ofthe Touch screen for 1 2 seconds the Key Card does not have to touch the keypad and can be 2cm away from the lock Confirm button The 2 button is used to complete verification after user PIN code is entered Wrong Code card Entry Limit After 5 unsuccessful attempts at entering a valid user PIN code or Valid Key Card the unit will shut down for 3 minutes and not allow operation during this time The lock will display how many minutes are left in this lock down mode as per page 6 Registration Button Located on the battery pack mounting Plate the Registration button is used for changing the user PIN code or enrolling new Key Cards Only in EZ mode Low Battery When the battery power is low the low battery icon will appear Further more the lock will beep 5 times when unlocked If battery power is completely lost the emergency power supply can be used Low Battery check The battery level can be checked without removing the batteries With a simple sequence of buttons you can check your battery level Between 100 30 Refer to page 10 For more details Emergency Power Suppl
5. present The key card s not present during this will no longer be valid e You are able to program a visitor code into the lock that may last 3 to 366 hours please refer to page 10 for more details It is important to note as a backup that you always need to enrol your user PIN code and key card Batteries Its important to use four quality Alkaline Batteries and all four batteries are replaced at the same time e Cryptic code function Prevent others from identifying your pin code during access the cryptic code function confuses the onlooker but at the same time allows you to still gain entry You are able to enter any random amounts of digits before you enter your actual code followed by your real pin code e g if you code is 1234 enter 2345672910171234 You are also able to enter you pin first followed by any random numbers e g 123427364830280 LOCKWOOD ASSA ABLOY Keypad Functions Smart Pad Low Battery Warning Wrong Code Entry Limit Warning KUID KID j ENN ED ASSA ABLOY 001 Internal Lock Functions Internal Lock Operation KEY INSIDE Locks or unlocks turn knob by turning key one full turn TURN KNOB Retracts latch bolt when unlocked SAFETYRELEASE Automatically unlocks the internal knob upon entry BOLT HOLD BACK To Engage Rotate turn knob fully clockwise To Release Rotate turn knob anti clockwise 001 LOCK BOLT HOLD BACK WITH KEY Prevents unauthorised hold back r
6. 001TOUCH i ASSA ABLOY USER GUIDE COCKUDOD ASSAABLOV 2 5 caro 8 O 0011 Digital nae d Deadlatch Ce ID ASSA ABLOY Introduction 2 Warnings 2 Main Features 3 Quick Guide Keypad Programming 4 Quick Guide Keypad Operation 5 Keypad Functions 6 Internal Lock Functions Battery Replacement 6 Product Definitions 7 EZ Mode Functions 8 EZ Mode Keypad Programming 9 EZ Mode Keypad Functions 10 Advanced Mode Functions 11 Advanced Mode Keypad Programming _ 242 Advanced Mode Keypad Functions 13 Emergency Power Supply 14 Troubleshooting 14 Advance Mode PIN Code Management ___ 5 Guarantee 15 Introduction The Lockwood 001TOUCH combines the trusted 001 Deadlatch lockset with a contemporary electronic aesthetic Users benefit from an interactive touchscreen that makes day to day access effortless and convenient The 001TOUCH features the choice of EZ or Advanced operating modes Locks are shipped as a default from the factory in EZ mode The desired operating mode should be determined before the completion of lock installation but can be changed at a later time if required The Quick Guide includes most of the functions required for initial setup and use for further instructions please refer to relevant sections The Quick Guide is for EZ mode only please refer to the other sections in the instructions for Advanced mode CAUTIO
7. 7890 Press the key on the touchscreen to entePMenu n de Enter Visitor PIN Can be 4 12 digits in length Press the E key on the touchscreen to U Enter or Accept entry Enter user Key Card s Up to 20 cards User Serial Number 01 20 User Pin code 21 40 User Card Registration User PIN code or Key Cards in EZ Mode A a ja Time setting in Visitor mode Repeat operation using settings indicated B Can be 3 336 Hours 22999 jaga CID ASSA ABLOY Keypad Programming Advanced Mode Register Change Master Code Enter current Master PIN code and Enter 1 to change the Master code Enter the new Master PIN code 6 digits followed by the key and followed by the key followed by the x key to complete M D ry Master Code Registration si D L ESU Key Card Registration Advanced Mode allows for up to 20 User PIN Codes and 20 Key Cards to be assigned User PIN Codes and Key Cards can only be added or removed once the Master code has been entered With the use of the Master Code a number of advanced functions outline on page 13 can be accessed A 6 digit Master Code can be entered Master code and User PIN Code must be different e o o o 12 LOCKUDOD ASSA ABLOY Keypad Functions Advanced Mode Master and User PIN Code Key Card registration M PIN Master Code Registration B D B User PIN Code Key Card R
8. If low battery indicator is lit page 6 change batteries User PIN codes will not register User PIN codes must consist of 4 to 12 digits to register In Advanced mode the same PIN code cannot be used for multiple users In EZ Mode User PIN codes must be entered within 20 seconds while the touchscreen is active or the process will have to be restarted In EZ Mode the user PIN code can only be registered using the Registration Button The star can not be used as part of the user PIN code In Advanced mode the Master code must consist of a minimum of 6 digits Master Code and User PIN Code cannot be the same The unit operates but it makes Check to see if Silent Mode is enabled page 10 amp 13 no sound The unit shows Low Battery e This is the indication alerting that it is time to replace the batteries Replace all four 4 batteries with new AA Alkaline batteries page 6 e Check batteries are installed and oriented correctly in the battery case e Check batteries are in good condition page 10 14 LOCKUDOD ASSA ABLOY Advance Mode PIN Code Management OO T oo e ww KKK ae ea ea TTT ea wl KKK e er TT Se ea ET seri3 13 User 14 User 15 peer OO Guarantee ASSA ABLOY Australia Pty Limited ASSA ABLOY warrants its Lockwood products against defects in workmanship and materials subject to the limitations and exclusions set out in this Warrant
9. N Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment IMPORTANT The accuracy of the door preparation is critical for the proper functioning and security of this cylindrical product Misalignment can cause premature wear and a lessening of security The 001TOUCH should only be serviced by a qualified technician Finish Care This lockset is designed to provide the highest standard of product quality and performance Care should be taken to insure a long lasting finish When cleaning is required use a soft damp cloth Using lacquer thinner caustic soaps abrasive cleaners or polishes could damage the coating and result in tarnishing This lock may not be used on moving doors i e Cars Trains or simular applications The lock is designed for residential and commercial applications only and door sizes between 32 50mm We highly recommend that a secondary entrance is required in the unlikely event of total failure This lock may not be used on fire doors LOCKUDOD ASSA ABLOY Main Features Low Battery Indicator Outside COCKWOOD oo ASSA ABLOY 2 Touch Screen Integrated Key Card Reader Numbers Confirm Button Knob Handle Inside 1 5VAA Alkaline Batteries Soft Reset Battery Pack Emergency 9V Power Supply Terminal Battery Pack Cover Open Button Dead
10. age caused by corrosion when the Lockwood product is used in a corrosive environment 5 Personal injury property damage or economic loss however caused Symmetry 5 Year Finish Warranty ASSA ABLOY Australia Pty Limited will replace five year branded Symmetry product if within five years from the proven date of purchase it tarnishes discolours or corrodes when properly installed and subject to no more than fair wear and tear Symmetry Everbrass Warranty Everbrass product is coated both on the exterior and interior surfaces with a lifetime anti tarnish finish ASSA ABLOY Australia Pty Limited will replace Everbrass branded product if it corrodes tarnishes or discolours when properly installed and subject to no more than fair wear and tear This Warranty is in addition to and not in substitution for any rights of the purchaser under the Trade Practices Act and state or territory legislation 15 gt ASSA ABLOY ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience LOCKWOOD ASSA ABLOY Lockwood is the leading brand in the Australian locking industry With an established reputation for high quality products this iconic brand provides a wide range of locking solutions to residential housing commercial building and industrial application markets Lockwood is supported by an extensive distribution and after sales support network Their customers include r
11. amp key 3 Enter digit E gt corresponding to the function to be performed followed by the key 4 Now enter desired value code followed by the E key 5 Press the key to complete the process and conclude the programming session U D B B Visitor Code Registration Ba New Visitor Code C Time Setting 3 336 hours 3 complete Note Actual time may vary by up to 10 3 Delete Visitor Code 5 Passage Mode Enable Complete le Disable Complete 7 voure Setting Silent Complete Normal Complete Complete B Battery Check Mode 1 3 appear through individual lighting e 3 greater 70 2 is between 35 70 1 less 35 Cancel 10 LOCKWOOD ASSA ABLOY Advanced Mode Functions Factory Defaults a Settings Factory Defaults Default Mode EZ Mode Master Code 123456 Passage Disable 0 Visitor Code Non z To set Advanced Mode slide Volume High switch to Advanced followed Relock time 5 sec Wrong code entry limit 5 times Shut down time 180 sec These values cannot be changed Programming Features Menu amp Icons i V Touch the screen with palm of hand M Enter Master PIN code 6 digits in length or fingers to begin and end actions Factory default 123456 PA A ae U Enter User PIN code Can be 4 to 12 digits a Dick Millest nUMmBEE in length Factory default 123456
12. egistration Pa 263 U D EQ continue Master Code Key Card Function 1 Touch screen with hand or fingers to activate 2 Enter 6 digit Master code followed by the amp key 3 Enter digit E gt corresponding to the function to be performed followed by the 6 key 4 Now enter desired value code followed by the amp key 5 Press the amp 3 key to complete the process and conclude the programming session M PIN Delete Code Card 63 Or 01 40 Ep continue M 2 Complete 2 Delete All gB D 6 Digits Complete Visitor Code Registration BT D New Visitor Code Time Setting 3 336 hours EQ compete Note Actual time may vary by up to 10 Delete Visitor Code B Passage Mode oe m Enable B Complete 3 Disable 3 Complete 7 OG Setting Silent Complete Normal Complete High Complete B Battery Check Mode 1 3 appear through individual lighting e 3 greater 70 2 is between 35 70 1 less 35 3 Cancel 13 CD ASSA ABLOY Emergency Power Supply 9V battery connections are located underthe front ofthe outside escutcheon In the case that the 4 AA alkaline batteries are completely discharged a 9V battery can be used to supply power tothe lock While connecting the 9V battery the lock can be operated as normal thus granting access so the 4 AA alkaline batteries can be replaced Discharged batteries should be replaced right away Troubleshooting Lock does not respond door is e The touchscree
13. elease To Engage Rotate turn knob fully clockwise and lock in rotated position by turning key in knob one full turn anti clockwise To Release Unlock turn knob by turning key one full turn clockwise and rotate turn knob anti clockwise Battery Replacement To install batteries first remove Battery Pack Cover by depressing the buttons on the top and bottom of the case then gently remove cover Insert 4 good quality alkaline AA batteries into the Battery pack as shown 2 in the upper battery compartment and two in the lower battery compartment Batteries must be new good quality alkaline and not be mixed between new and old Caution Dispose of them responsibly and do not throw batteries in fire LOCKUDOD ASSA ABLOY Product Definitions EZ Mode Factory default In this mode you are able to enrol one User PIN code as well as 20 additional key cards This mode is normally used for a residential homes Advanced Mode This mode can be selected at point of installation Advanced mode enables you to have a master code the master code is able to add 20 different users with a PIN code and 20 Users with a Key Card 40 users in total Only the master can add or delete users using their PIN This is normally used to control access or where users may be removed when reguired User PIN Code Is a personalised identification number that consist of 4 12 digits Master Code Is a personalised identification number that consist
14. etailers architects trade and industrial personnel locksmiths and security dealers ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience ASSA ABLOY is represented in all major regions in both mature and emerging markets with leading positions in Australia Europe and North America As the world s leading lock group ASSA ABLOY offers a more complete product range of door opening solutions than any other company on the market 1300 LOCK UP 1300 562 587 lockweb com au ASSA ABLOY Australia Pty Limited 235 Huntingdale Rd Oakleigh VIC 3166 ABN 90 086 451 907 2011 The Global Leader in Door Opening solutions
15. n will become active when pressed with the palm or fingers in at least open and accessible 3 areas simultaneously Use a larger area of the palm or fingers and verify contact with at least 3 areas page 5 e If touchscreen numbers are visible check to see if they respond when pressed Check batteries are installed and oriented correctly in the battery case e Check batteries are in good condition page 10 replace batteries if discharged page 6 e Check to see if touchscreen cable is properly connected and not pinched e Push Soft Reset until confirmation sound is heard Lock does not respond door is e Batteries may be completely discharged locked and inaccessible Connect a 9 volt battery to the emergency power supply terminal which is located on the outside escutcheon under the knob With the 9 volt battery connected palm the touchscreen enter user PIN code and palm touchscreen again page 5 Replace batteries page 6 The unit is on for a while and then e The batteries do not have enough power Replace the batteries shows no reaction Lights dim Unit chimes to indicate code accep e Check to see if there is another locking device on the door i e deadbolt tance but the door will not open e Check the door gaps for any foreign objects between door and frame Unit operates to allow access but Check to see if Passage Mode is enabled will not automatically re lock Disable Passage Mode to lock the door page 10
16. y 9V battery connections are located under the front of the outside escutcheon In the event that the four AA alkaline batteries are completely discharged a 9V battery can be used to supply power to the lock While connecting the 9V battery the lock can be operated as normal thus granting access so the four AA alkaline batteries can be replaced Soft reset Located in between the Emergency 9V Power socket this small hidden button is used to refresh the internal software all your settings will remain i e user Pin code and Key cards This can be pushed with a small object i e pen Once pressed you will hear confirmation This is only ever used in the event your lock malfunctions Passage Mode Enabling Passage mode allows continuous entry for non restricted traffic Passage mode is enabled or disabled through feature programming Refer to page 10 For more details Visitor PIN The Visitor PIN is a temporary code that expires after a period between 3 336 hours This is ideal when a plumber or an electrician requires access to your house for a few hours or when your neighbour is looking after your home for up to 2 weeks All you have to do is program the PIN and the duration Time may vary up to 10 refer to page 10 for more details Volume adjustment You have 3 levels of volume adjustment 1 Silent 2 Medium 3 Loud 3 Factory default Silent Mode Enabling Silent mode shuts off the code confirmation tone playback for use in quiet areas
17. y If within the normal working life of a product it is found to be defective and none of the limitations and exclusions set out in this Warranty apply ASSA ABLOY will supply the same or equivalent product free of charge This is the only remedy granted by ASSA ABLOY under this Warranty Limitations All electrical and electronic components used in ASSA ABLOY s Lockwood range of products excluding batteries are guaranteed for a period of 12 months from the date of proof of purchase unless stated otherwise Exclusions This Warranty does not cover 1 Damage to or malfunction or failure of the Lockwood product caused or contributed to by a improper installation or failure to follow fitting instructions b improper maintenance c fair wear and tear d any modification or repair which has not been authorized by ASSA ABLOY e use of substitute or replacement parts or cylinders other than genuine ASSA ABLOY parts or cylinders or f use of batteries other than those specified by ASSA ABLOY 2 The cost of a removal and or replacement of the Lockwood product b freight and or travelling time c replacement batteries or d any modification or repairs to a Lockwood product unless authorised by ASSA ABLOY 3 Damage to or deterioration of the plated finishes Florentine Bronze Architectural Bronze Polished Brass Gold and Satin Brass which are classified as soft finishes and are subject to deterioration under some environmental conditions 4 Dam