Home

User Guide

image

Contents

1. Edit User Data Set up user accounts for this se TECUM User inrTormation Anonymous User testl test2 test3 Enter user name testi Enter password er Confirm password ELTE Not Figure 21 IDA Configure Server Edit User Information window 32 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel RMM4 6 Select Apply to save your settings Intel Deployment Assistant Server Management Settings Finish Apply Configuration Select Apply to configure your server with the following settings Server Management Settings Figure 22 IDA Configure Server Apply Configuration window Revision 2 2 33 Configuring Integrated BMC Web Console and Intel RMM4 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Deployment Assistant Server Management Settings FIR Applying Configuration Committing LAN Configurations Figure 23 IDA Configure Server Applying Configuration progress window 34 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel RMM4 7 Keep a record of the DHCP Host Name and assigned IP address These will be needed later when you are trying to connect to the Integrated BMC Web Console 8 In order for the configuration setti
2. The four tabs on the horizontal menu allow you to navigate within the Integrated BMC Web Console Each of these tabs contains a secondary menu on the left edge of the browser window For detailed information on the specific functions of secondary menu item see Chapter 7 Intel Integrated BMC Web Console Options The top horizontal toolbar also has the Logout Refresh and Help buttons Click these buttons to perform tasks as shown in the following table Table 7 Horizontal Toolbar Buttons Click this button to end the current Web Console session Note that a remote console KVM window if active will be closed when you log out After logging out the Web Console will return to the Login screen Click this button to view a brief description of the current page in a frame at the right hand side of the browser window Close the Help frame by clicking the X in the upper right corner of the frame or by clicking the HELP button again 40 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Getting Started with Intel RMM4 Operation 5 4 Online Help The Web Console user interface gives specific online help for each page For additional information on a certain topic or group of options click the button on the top horizontal toolbar to view the online help as shown in Figure 28 The right Help frame is visible only when the online Help is being accessed intel Integrated BMC Web
3. Figure 17 IDA Configure Server Communication Options Window No Dedicated Server Management NIC installed 28 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel RMM4 2 Select IP Address from a DHCP Server or Static IP Address a IfIP Address from a DHCP Server is selected configure the DHCP Host Name as shown in Figure 18 b If Static IP Address is selected configure the IP address Subnet Mask and Gateway as shown in Figure 19 3 You can also select Enable Serial Over LAN and Configure Alert on these screens LS Intel Deployment Assistant intel My Server Advanced Help dl Exit Server Management Settings LAN Channel 3 Intel Remote Management Module Finish Configure the LAN Channel 3 access settings 4 Enable LAN Channel 3 IP Address from a DHCP server DHCP Host Name Bmc Host Name Static IP Address Enable Serial Over LAN l Configure Alert cance Figure 18 IDA Configure Server Configure LAN Channel 3 Intel RMM4 DMN IP Address from a DHCP server window Revision 2 2 29 Configuring Integrated BMC Web Console and Intel RMM4 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Deployment Assistant Server Management Settings EISE LAN Channel 3 Intel amp Remote Management Module Configure the LAN Channel 3 access set
4. HELP E System Information Server Health Configuration Remote Control e LOGOUT REFRESH Remote Control This section allows you to perform various remote operations on the server such as launching the remote console E Power Control and Status Console Redirection The current server power status is shown below To perform a power control operation select one of the options below and press Perform Action Server Power Control Host is currently ON Reset Server J Power OFF Server Power ON Server 2 Power Cycle Server Perform Action Figure 82 Remote Control Server Power Control Page on S1200BTL platforms The following power control operations can be performed Table 21 Remote Control Power Control Options mme C o mI Reset Server Select option to hard reset the host without powering off Power OFF Server Select option to immediately power off the host Power ON Server Select option to power on the host Power Cycle Server Select option to immediately power off the host then power it back on after one second Perform Action button Click to execute the selected remote power command Note All power control actions are done through the BMC and are immediate actions It is suggested to gracefully shut down the operating system via the KVM interface or other interface before initiating power actions 94 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide
5. Note The Username and Password are case sensitive Any username and password could be used except anonymous 38 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Getting Started with Intel RMM4 Operation 5 3 Navigation After successful login to the Integrated BMC Web Console module the Integrated BMC Web Console home page appears as shown in Figure 27 intel Integrated BMC Web Console as hi T3 HELP REFRESH System Information Server Health Configuration Remote Control ea LOGOUT y J J 4 System Information E This section contains general information about the system I Summary System Information System Information FRU Information Host Power Status Host is currently ON RMM Status Intel R RMM installed System Diagnostics Device BMC Available Yes a oe BMC FW Build Time Jan 6 2011 11 11 29 BMC FW Rev 01 02 Boot FW Rev 00 02 SDR Package Version SOR Package 0 11 Mgmt Engine ME FW Rev 02 06 171 0 Done G Local intranet Protected Mode Off fay 0 Figure 27 Integrated BMC Web Console Home Page The top horizontal toolbar within the Integrated BMC Web Console home page has four tabs Click these tabs to get specific system information and perform tasks as shown in the following table Table 6 Integrated BMC Web Console home page tabs Click this tab to access general information about the ser
6. cccccccssecececeseeeeseeeeeeeeeeaeeeesseaeeeesseeeeeeeeas 43 6 2 Mali AJ rero cO 45 6 3 Remote Console COMTO BI assai ott decade cedet atalino sale 46 6 3 1 Remote Console Video MENU oreiro E A 46 6 3 2 Remote Console Keyboard Menu cccccccccsesecceceeeeeeeceeeeeeeseeeeeeeeeeeeeeeseeeseeeeas 47 6 3 3 Remote Console Mouse Me nu cccccccseecceeceeseceeceeeeceeeeeeeeeeseeaeeeeeeseeeeessaaeeeess 50 6 3 4 Remote Console Options Menu ccccccccccccseeeceeseeeeeeseeeeseeseeeeeeeseeeeeeeseeeseeseas 51 6 3 5 Remote Console Device Menu cccccccssecccccesseceeseeseceeseeeeeeeseeeeseeseeeeeeseeeeeeseas 52 6 4 Remote Console Status Line saisi eeescs serae deae dear iad de 52 7 Intel Integrated BMC Web Console Options eee nnnnes 53 7 1 System IALONMAUIOR TaD t RR a TS 54 7 1 1 SYSTEM Information PAGE cscccccsescecceseecceeeeccceuseecsseecseueeessaeeeesuueeessueeessgeessaaes 54 7 1 2 Field Replaceable Unit FRU Information Page cccceeceesseeeeeeeeeeeeeeeeeeeeeeeeas 56 1 39 System Debug LOG Page cic NEAR Ee m oed aetate da uec anie datus 57 7 1 4 DIMM Intormatlon Page ient Ea RR vere dawn Quia Ma Fea Rue L E RERUS a ie vua E ek Deda E esu pe 61 7 1 5 CPU Information Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families seeeeeeeseeeeeeeen eese 62 7 2 Serv
7. 128 Save button Click to save any changes made 72 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 3 3 Users page The User List page lists the configured users along with their status and network privilege It also provides the capability to add modify and delete users See Figure 62 for details intel Integrated BMC Web Console TL ype System Information Server Health Configuration Remote Control LOGOUT REFRESH HELP Configuration Use these pages to configure various settings such as alerts users or network User List Network The list below shows the current list of configured users Users If you would like to modify or delete a user select their name in the list and click Modify User or Delete User To add a new user select an unconfigured i slot and click Add User Login LDAP Number of configured users 5 SSL 4 A Sasi anonymous disabled Administrator root disabled Administrator Mouse Mode admin ENABLED Administrator Keyboard Macros test2 disabled Administrator test3 disabled Administrator Alerts Alert Email co Cc tn amp WH a o eb eb d oC N 1 Q i 2 i i 2 i Q Q 1 Q 1 i i Q i i i Q Q i Q n Figure 62 Configuration User List Page This page allows the operator to configure the IPMI users and privileges for this server
8. j J Sr System Information Serwer Health Configuration Remote Control c LOGOUT System Information This section contains general information about the system The following operations generate an encrypted zip file that contains debug information which is useful to the system manufacturer for problem resolution The information collected includes Baseboard Management Controller BMC status BMC System Information configuration settings BMC Sensor readings Power supply data System Event Log sensor readings SMBIOS tables CPU ves i machine check registers and PCI configuration space information If you elect to forward this information to a third party it FRU Information contains no personal information and may be used for the purpose of investigating the problem Downloading debug EM information by clicking on the link does not change any configuration files or read application data on any of the hard drives System Debug Log Log files should be sent to the system manufacturer for analysis CPU Information DIMM Information 9 System Debug Log 62 System amp BMC Debug Log System Debug Log Last Log None Figure 51 System Debug Log Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families A list of data that may be captured using this feature includes but is not limited to Platform sensor readings This includes all readable sensors that can be accessed by the BMC
9. 2 the alert should be sent to Up to 2 destinations can be selected for each LAN channel Save button Click to use selected setup Send Test Alerts button After configuring select this to send a test alert On an EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families there is an additional option to Globally Enable Platform Event Filtering This can be used to prevent sending alerts until you have fully specified your desired alerting policies See Figure 77 for details System Information Server Health Configuration Remote Control a LOGOUT REFRESH F Configuration Use these pages to configure various settings such as alerts users or network Alerts IPv4 Network Configure which system events generate Alerts and the external network destinations they should be sent ta IPv amp Network Tm Globally Enable Platform Event Filtering amp amp Enabled Disabled Login Select the events that will trigger alerts C Temperature Sensor Gut of Range C Watchdog Timer EP T System Restart E Voltage Sensor Out of Range VLAN C Fan Failure O Chassis Intrusion C Power Supply Failure E Memory Error SSL C BIOS Post Error Code C FRB Failure Remote Session O Node Manager Exception O Hard Drive Failure Mouse Mode Check All Clear All Keyboard Macros LAN Channel to Configure Baseboard Mgmt Ieee eee eee eee cre tere creer Alerts X PE x Aler
10. Dedicated Server Management NIC on an Intel Pedestal Server System Most Intel Pedestal Server Systems allow the Intel Dedicated Server Management NIC module to be mounted to the chassis Table 4 lists all of the Intel Pedestal Server Systems that support a chassis mounted Intel Dedicated Server Management NIC module The following are steps should be used when installing the Dedicated Server Management NIC module on those server systems 1 Ensure that AC power has been removed from the system and that you have waited at least 10 seconds after removing power 2 Attach the metal fastening bracket to Intel Dedicated Server Management NIC module AF003756 Figure 8 Attaching the bracket to Intel Dedicated Server Management NIC module Note For the next two steps see your specific Inte Server Systems Technical Product Specification and Inte Server Systems Service Guide for more details If appropriate Table 4 will list the figure showing the installation for that specific system 3 Push out and remove the metal cover on the chassis where the NIC RJ 45 receptacle will align Caution Carefully remove the metal cover with pliers directly removing it with finger has potential risk 4 Attach the cable to the cable connector on the Intel Dedicated Server Management NIC module Mount the NIC module to the back of the chassis and secure the metal fastening bracket with two screws This will align the RJ 45 with the opening in th
11. FW and have associated SDRs populated in the SDR repository This does not include any event only sensors All BIOS sensors and some BMC and ME sensors are event only meaning that they are not readable using an IPMI Get Sensor Reading command but rather are used just for event logging purposes SEL The current SEL contents are saved in both hexadecimal and text format CPU memory register data useful for diagnosing the cause of the following system errors CATERR ERR 2 SMI timeout PERR and SERR The debug data is saved and timestamped for the last 3 occurrences of the error conditions a PCI error registers b MSR registers c Integrated Memory Controller iMC and Integrated I O IIO module registers Revision 2 2 59 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide BMC configuration data BMC FW debug log that is SysLog Captures FW debug messages Non volatile storage of captured data Some of the captured data will be stored persistently in the BMC s non volatile flash memory and preserved across AC power cycles Due to size limitations of the BMC s flash memory it is not feasible to store all of the data persistently SMBIOS table data The entire SMBIOS table is captured from the last boot PCI configuration data for on board devices and add in cards The first 256 bytes of PCI configuration data is captured for each device for each boot Sys
12. Figure 33 Remote Console Main Window cccccccseeceeeceeeceeeceeeeeeeseeeeeeeseeeeeeeseaaeeeessaeeeeeeas 45 Figure 34 Remote Console Control Bar sese nennen nnn nnns 46 Figure 35 Remote Console Video Menu sseeessssssesseeeeeee nennen nnne nnn 46 Figure 36 Remote Console Keyboard M nu cccccssecceeceeeeeeeceeseeeeseeeeeeeseeeeceseeeaeeeeseaeeeeseas 47 Figure 37 Remote Console Keyboard Language Sub Menu cccseeeececeeeeeeeeeeeeeeeeseneeeeeeas 48 Figure 38 Remote Console Keyboard Soft Keyboard Sub Menu eeesussssse 49 Figure 39 Remote KVM Soft Keyboard essensie E e nnns 49 Figure 40 Remote Console Mouse Menu ccccccceeeceeeceeeeeeceeeeeeeseeeeceesseeeeeeseaaeeeeesaeeeeseas 50 Figure 41 Remote Console Mouse Menu on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families sese 50 Figure 42 Remote Console Mouse Menu Mode selection on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 50 Figure 43 Remote Console Options M Nu cccccccseeeececeeeeeeeceeeeeeeseeeeceesseeeeeeseeeeeeesseeeeeeeeas 51 Figure 44 Remote Console Device Menu ccccccccseeeececeeeeeeeceeeeeeeseeeeeeeseeseeeeseeaeeeeseeeeeeseas 52 CURE 7A 5 Slat SLING mmm 52 FIGUre 46 BUSY INGICAIO
13. Guide CPU memory register data useful for diagnosing the cause of the following system errors CATERR ERR 2 SMI timeout PERR and SERR The debug data is saved and timestamped for the last 3 occurrences of the error conditions a PCI error registers b MSR registers c Integrated Memory Controller iMC and Integrated I O IIO module registers BMC configuration data BMC FW debug log that is SysLog Captures FW debug messages 7 1 3 2 System Debug Log Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families The System Debug Log page can be used to collect system debug information on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families See Figure 51 for details From the System Debug Log screen you will be able to select either the System Debug Log or the System amp BMC Debug Log Select one of the two and press the Run button It may take some time for the diagnostics to run Once the debug log dump is finished you can click the diagnostic filename to save the results as a zip file on your client system The file can then be sent to your system manufacturer or an Intel support engineer for analysis 58 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options intel Integrated BMC Web Console i i PE fi REFRESH 0 HELP
14. Hold Right Alt Key 1 Hold Left Ctri Key Hold Left Alt Key Left Windows Key gt Hold Down Right Windows Key gt Press and Release Ctri Alt Del Ctri Alt Backspace Ctri Alt Left Ctri Alt Right Figure 36 Remote Console Keyboard Menu Using this menu you can do the following e Language Controls the keyboard language layout e Soft Keyboard Displays and controls the Soft Keyboard window e Hold Ctrl Alt Windows keys Allows simulating holding down these special keys on the remote keyboard On the local keyboard these special keys are processed by the local OS and not passed on to the remote OS e Ctrl Alt Del Ctrl Alt Backspace Ctrl Alt Left Ctrl Alt Right Issue a fixed special key combination to the remote OS 6 3 2 1 Keyboard Language Layout The Remote Console supports the following keyboard language layouts English Dutch French German Italian Russian and Spanish Revision 2 2 47 Remote Console KVM Operation Intel Remote Management Module 4 and Integrated BMC Web Console User Guide H H Auto Detect Soft Keyboard i English l Hold Right Ctrl Key O English UK l Hold Right Alt Key O Dutch J Hold Left Ctrl Key J French LJ Hold Left Alt Key 2 German Left Windows Key Italian Right Windows Key O Russian Ctr Alt Del Spanish Ctri Alt Backspace Ctri Alt L eft Ctrl Alt Right Figure 37 Remote Console Keyboard Language Sub Menu In order for local k
15. IPv4 Network You can view and modify the login security settings on this page Select how many failed login attempts occur before a user is locked out and for how long IPv6 Network Users Failed Login Attempts 3 Login User Lockout Time min 1 LDAP Force HTTPS C Enable hino Web Session Timeout 1800 Second s SSL Remote Session Save Mouse Mode Keyboard Macros Alerts Alert Email Node Manager Figure 66 Configuration Login Security Settings Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 7 3 5 LDAP Settings Page To enable disable LDAP check or uncheck the Enable LDAP Authentication checkbox respectively intel Integrated BMC Web Console T y j p f it FF System Information Server Health Configuration Remote Control Configuration P Use these pages to configure various settings such as alerts users or network LDAP Settings Network Check the box below to enable LDAP authentication and enter the required information to access the LDAP server Press the Save button to save your changes Users Login Enable LDAP Authentication LDAP GUN SSL Port Remote Session IP Address Mouse Mode Searchbase Keyboard Macros Bind DN Alerts Bind Password Alert Email Sae Figure 67 Configuration LDAP Settings Page 76 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC
16. Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 7 1 5 CPU Information Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1 600 1400 Product Families The CPU Information page displays information on the processors that are installed on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families See Figure 53 for details intel Integrated BMC Web Console LE 4 y T I a al S ENS P5 OA p ENE System Information Server Health Configuration Remote Control e LOGOUT REFRESH HELP jw A System Information This section contains general information about the system This page lists CPU data as reported by BIOS on the last successful system boot System Information CPU Information Socket Designation Manufacturer FRU Information System Debug Log CPU Information Version DIMM Information Processor Type Family Speed Number of Cores Voltage Socket Type Status Serial Number Asset Tag Part Number CPU Information Socket Designation Manufacturer Version Processor Type Family Speed Number of Cores Voltage Socket Type Status Serial Number Asset Tag Part Number CPU 1 Intel Genuine Intel R CPU 2 30GHz Central Processor Intel Xeon 2 3 GHz 8 1V Other Populated Enabled CPU 2 Intel Genui
17. Remote Session Page Use this page to enable disable encryption on KVM or Media during a redirection session Figure 70 shows the details for a S1200BTL system Revision 2 2 79 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide intel Integrated BMC Web Console m System Information Server Health Configuration Remote Control e LOGOUT REFRESH HELP L Jas Configuration y n mn Use these pages to configure various settings such as alerts users or network Remote Session Network The following options allow the user to enable or disable encryption on KVM or Media data during a redirection session Users Login E Enable KVM Encryption aia F Enable Media Encryption AL Remote Session USB Key Emulation Type Floppy Mouse Mode Keyboard Macros Save Alerts Alert Email Figure 70 Configuration Remote Session Page on S1200BTL platforms The following table lists the options allowing you to enable or disable encryption on KVM or media data and the USB Key Emulation type selection used during a redirection session Table 15 Configuration Remote Session Options Enable Disable encryption on KVM or Media data during a redirection session Enable KVM Encryption Note KVM and Media encryption are enabled by Enable Media Encryption default Note Disabling encryption can improve performance of KVM or Media redire
18. Togliere tutte le spine dei cavi del sistema dalle prese elettriche 4 Identificare e sconnettere tutti i cavi attaccati ai collegamenti I O od alle prese installate sul retro del sistema 5 Qualora si tocchino i componenti proteggersi dallo scarico elettrostatico SES portando un cinghia anti statica da polso che attaccata alla presa a terra del telaio del sistema qualsiasi superficie non dipinta 6 Non far operare il sistema quando il telaio senza le coperture Se il sistema stato a lungo in funzione il microprocessore e il dissipatore di calore potrebbero essere surriscaldati Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio E consigliabile l uso di guanti di protezione Revision 2 2 5 Introduction Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 1 4 Support Information If you encounter an issue with your Intel RMM4 follow these steps to obtain support 1 Visit the following Intel Support web page at htip Awww intel com p en US support This web page provides 24x7 support when you need to get the latest and most complete technical support information on all Intel Enterprise Server and Storage Platforms Information available at the support site includes e Latest BIOS firmware drivers and utilities e Product documentation installation and Quick Start Guides e Full product specifications technical advisories and erra
19. are not limited to normal floppy CDROM sizes and will be as large as the device or file being redirected A USB Key drive is redirected as a virtual floppy device rather than a USB device to allow the loading of custom device drivers during remote OS installation which may require a floppy drive There is only one virtual CDROM and one virtual floppy device on the remote system allowed so only one local item of each type can be redirected at a time Only one Remote Console window can be doing media redirection at any given time 6 4 Remote Console Status Line The status line at the bottom of the Remote Console screen shows the console state as shown in Figure 45 As you navigate the menu options the status line gives a more detailed definition of each option Keyboard Video and Mouse redirection Figure 45 Status Line 52 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 Intel Integrated BMC Web Console Options This chapter gives you a detailed description of each Integrated BMC Web Console page It is organized in sections corresponding to the four tabs in the horizontal menu Within each section each menu on the left hand side is illustrated and described in detail Notes e The first menu item for each tab is the default page which appears when the tab is selected e Similar information about each page is available in the Web Console by
20. changed with the locale command but not while an application such as the Remote Console is running There is also an OS keyboard layout that can be changed independently of the language If the OS keyboard layout does not match the OS language setting you may need to manually select the Remote Console layout 48 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Remote Console KVM Operation On the other hand with Linux Java there is less reverse translation required by the application than under Windows and is more likely that a mismatched configuration will work anyway 6 3 2 2 Soft Keyboard Click Keyboard to open the Keyboard menu with options to perform tasks as shown in Figure 38 i Hold Right Ctrl Key Follow Local i Hold Right Alt Key English T Hold Left Ctrl Key O English UK J Hold Left Alt Key CJ Dutch Left Windows Key French Right Windows Key C German Ctri Alt Del 2 Italian Ctri AlteBackspace Russian Ctrl Alt Left Spanish Ctri Alt Right Figure 38 Remote Console Keyboard Soft Keyboard Sub Menu The Soft Keyboard window is displayed and closed either by selecting the Keyboard gt Soft Keyboard gt Show checkbox or the ALT S shortcut E Soft Keyboard English mm E EMEN 1 2 3 4 5 6 7 8 9 0 asec m fr z S alw el rit y u i elp L1 9 9 5 t amp c als a f g ni k t gt t S e zx e v
21. is one of two expected events from BIOS on every power on Asserted reports Timestamp Clock Sync Event is one of two expected events from BIOS on every power on Asserted reports Timestamp Clock Svnc Event is one of two expected Figure 57 Server Health Event Log Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 66 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 2 3 Power Statistics Page The Power Statistics page displays the systems power statistics in watts as shown in Figure 58 inte Integrated BMC Web Console System Information Server Health Configuration Remote Control LOGOUT REFRESH HELP Server Health This section shows you data related to the server s health such as sensor readings and the event log Power Usage Summary Sensor Readings System power statistics in watts Event Log Minimum OW Power Statistics l Current 95W n Maximum 301W Average 96W Figure 58 Server Health Power Statistics Page Revision 2 2 67 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 7 3 Configuration Tab The Configuration tab is used to configure various settings such as IPv4 Network Users Login LDAP SSL Remote Session Mouse Mode Keyboard Macros Alerts and Alert
22. module o Bag containing screws metal fastening bracket PCI slot brackets and cablings e RMMA full edition 2 AXXRMMAR for Intel server boards S2600GZ S2600GL S2400BB and S2400EP which contains the following components o Intel Remote Management Module 4 Lite module o Intel Dedicated Server Management Network Interface Card NIC module 2 o Bag containing screws The installation will vary between the chassis configurations The following sections provide installation instructions Caution Intel RMM4 Lite and RMM4 DMN are NOT hot swappable Before removing or replacing it you must first take the server out of service turn off the system by pressing the power button and unplug the AC power cord from the system or wall outlet and wait for at least 10 seconds before installing the module 3 3 1 Installation of Intel RMM4 Lite on Intel Server Boards The following are steps are for installing Intel RMM4 Lite on Intel Server Boards These installation steps apply to all system types 10 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Hardware Installations and Initial Configuration 1 Ensure that AC power has been removed from the system and that you have waited at least 10 seconds after removing power 2 Find the RMM4 Lite connector as specified as listed in Table 2 for your specific server board See your Intel Server Boards Technical Product Specification TPS for detail
23. operating system As a system administrator you can use the Intel Integrated BMC Web Console to gain location independent remote access to respond to critical incidents and to undertake necessary maintenance Designed to work with the Baseboard Management Controller BMC the Intel RMMA is a small form factor mezzanine card that enables remote KVM and media redirection on your server system via the built in Web Console from anywhere at any time 1 1 Target Audience This User Guide is intended for system technicians who are responsible for monitoring their server systems with the Intel Integrated BMC Web Console As a system administrator you can use the Intel Integrated BMC Web Console to gain location independent remote access to respond to critical incidents You can use the Intel RMMA to install update and monitor your operating system 1 2 Terminology The following table lists the terminology used in this document and the description Table 1 Terminology Revision 2 2 1 Introduction Intel Remote Management Module 4 and Integrated BMC Web Console User Guide SDR Sensor Data Record TCP IP Transmission Control Protocol Internet Protocol UDP User Datagram Protocol 1 3 Safety Information amp WARNING Before working with your Intel RMM4 server product whether you are using this guide or any other resource as a reference pay close attention to the safety instructions You must adhere to the assembly instruct
24. tab The Remote Control tab helps you perform the following remote operations on the server e Console redirection e Server power control 7 4 1 Console Redirection Page By default the Remote control tab opens in the Console Redirection page Launch the remote console KVM redirection window from this page LEJ gt NOT E intel Integrated BMC Web Console T REFRESH Q HELP LU System Information Server Health Configuration Remote Control c LOGOUT Remote Control This section allows you to perform various remote operations on the server such as launching the remote console Console Redirection Console Redirection Press the button to launch the redirection console and manage the server remotely Server Power Control Launch Console Figure 81 Remote Control Console Redirection Page Click the Launch Console button to launch the redirection console and manage the server remotely Note Java Run Time Environment JRE Version 6 Update 22 or higher must be installed on the client prior to launch of JNLP file Revision 2 2 93 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 7 4 2 Server Power Control Page The Server Power Control page shows the power status and allows power reset control of the server Figure 82 shows the details for a S1200BTL system intel Integrated BMC Web Console j jj
25. to the back of the chassis and secure the metal fastening bracket with two screws This will align the RJ 45 with the opening in the Revision 2 2 13 Hardware Installations and Initial Configuration Intel Remote Management Module 4 and Integrated BMC Web Console User Guide chassis Attach the cable to the RMM4 NIC connector as specified in Table 3 on the server board Caution Care should be used when attaching or removing this cable Mishandling the cable could cause damage AF003759 Figure 6 Adding the Intel Dedicated Server Management NIC module in the Intel Server System R1304BTLSFAN R1304BTLSHBN and R2000SC Family 14 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Hardware Installations and Initial Configuration 4 If no cable and bracket were required see Table 3 mount the NIC module to the Intel Serve system board and secure to the standoffs with two screws Chassis Back Opening Filler 7 AF004137 Figure 7 Adding the Intel Dedicated Server Management NIC module in the Intel Server System R1000BB R1000GZ GL and R2000GZ GL Familes 5 Replace the chassis cover attach AC power and connect a network cable to the Intel Dedicated Server Management NIC module Revision 2 2 15 Hardware Installations and Initial Configuration Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 3 33 Installation of the Intel
26. 1400 Product Famili s ccccccccccecseeeeeeceeeeceeseeeeeeeseeeeeeesseeeeeeseas 88 Figure 78 Configuration Alert Email Pags escea E 89 Figure 79 Configuration Node Manager Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 90 Figure 80 Configuration Node Manager Page with Use Poilicy Suspend Period selected 92 Figure 81 Remote Control Console Redirection Page cecccccccssseseeeeeeeeeeseeeeesesaeeeeeeeeesaaeees 93 Figure 82 Remote Control Server Power Control Page on S1200BTL platforms 94 Figure 83 Remote Control Server Power Control Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 95 Figure 84 Remote Control Virutal Front Panel Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families sse 96 Revision 2 2 IX List of Tables Intel Remote Management Module 4 and Integrated BMC Web Console User Guide List of Tables EE MN uis M UT Nem 1 Table 2 Intel Server Boards RMM4 Lite Connector Locations ee 11 Table 3 Intel Rack Server Systems Chassis mounted Intel Dedicated Server Management NIC RMM4 NIC Connector Locations 3 5 nto Eee Ee Rr FUr RE I e eR ebeb Sus tis po P RS 12 Table 4 Intel Pe
27. 3 50 179 06 15 2011 11 50 54 178 06 15 2011 11 50 54 177 06 15 2011 11 50 13 176 06 15 2011 11 50 13 175 06 15 2011 11 46 39 174 06 15 2011 11 46 38 173 06 15 2011 11 45 02 aA A M a a a a am o A BIOS Evt Sensor BIOS Evt Sensor IPMI Watchdog BIOS Evt Sensor BIOS Evt Sensor BIOS Evt Sensor BIOS Evt Sensor BIOS Evt Sensor BIOS Evt Sensor BIOS Evt Sensor mman mn Clear Event Log Save Event Log 4 System Event System Event Watchdog 2 System Event System Event System Event System Event System Event System Event System Event B Event Log 300 event entries reports Timestamp Clock Sync Eventis one of two expected events from BIOS on every power on Asserted reports Timestamp Clock Sync Event is one of two expected events from BIOS on every power on Asserted reports the watchdog initiated a hard reset Asserted reports Timestamp Clock Sync Event is one of two expected events from BIOS on every power on Asserted reports Timestamp Clock Sync Event is one of two expected events from BIOS on every power on Asserted reports Timestamp Clock Sync Event is one of two expected events from BIOS on every power on Asserted reports Timestamp Clock Sync Event is one of two expected events from BIOS on every power on Asserted reports Timestamp Clock Sync Event is one of two expected events from BIOS on every power on Asserted reports Timestamp Clock Sync Event
28. Console i 17 DH p ui 5 System Information Server Health Configuration Remote Control cd LOGOUT 9 REFRESH HELP E 4 System Information This section contains general information about the system summary System Information EJ Help System Information the server Host Power Stetus Shows the power status of the host on off RMM Status Indicates if the Remote Management Module remote KVM cand iz present Device BMC Available Indicates whether the BMC is awailabl BMC FW Build Time The date and time of the installed BMC Tar arm System Information Host Power Status Host is currently ON RMM Status Intel R RMM installed Device BMC Available Yes BMC FW Build Time BMC FW Rev Boot FW Rev SDR Package Version Mgmt Engine ME FW Rev 02 06 171 0 FRU Information System Diagnostics sitne zioni Jan 6 2011 11 11 25 01 02 00 02 SDR Package 0 11 BMC FW Rev Major and miror revision of the BMC Boot FW Rev Major and minor revision of the BOOT firmware SDR Package Version Version of SDR package ME FW Rew Major and miror firmware revision for available if the host is powered on Done E Local intranet Protected Mode Off f 90 Figure 28 Launching the Online Help 5 5 Logging Out Click the D ioco button to log out the current user and revert to a new login screen as shown in Figure 29 and Figure 30 Revision 2 2 41 Getti
29. Email as discussed in the following subsections In addition on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families IPv6 VLAN and Node Manager can also be configured Click on the Configuration tab to select the various pages By default this tab opens the Network Settings page or the IPv4 Network page 7 3 1 Network or IPv4 Network Page The Network or IPv4 settings page is used to configure the IPv4 network settings for the server management LAN interface to the BMC controller See Figure 59 or Figure 60 for details intel Integrated BMC Web Console System Information Server Health Configuration Remote Control e LOGOUT REFRESH HELP p PEX iam Configuration HP Use these pages to configure various settings such as alerts users or network Network Settings Network You can view and modify the network settings on this page Select whether to obtain an IP address automatically or manually configure one Users Login LAN Channel Baseboard Mgmt v LDAP MAC Address SSL Obtain an IP address automatically use DHCP Remote Session Use the following IP address Mouse Mode IP Address 0 0 0 0 Keyboard Macros Subnet Mask 0 00 0 Alerts Default Gateway 0 0 0 0 Alert Email Primary DNS Server Secondary DNS Server Save Figure 59 Configuration Network Settings Page on S1200BTL platforms 68 Revision 2 2 Intel Remote Management Module 4 and Integra
30. Figure 56 Server Health Event Log Page on S1200BTL platforms The following table lists the options available in this page Table 10 Server Health Event Log Options on S1200BTL platforms EMEN re Event Log Category pull down box Select the type of events to display in the list Event Log List Selected sensors are shown with their name status and readings This includes a list of the events with their ID time stamp sensor name sensor type and description Click to clear the event logs Clear Event Log button On an EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families you also get a Save Event Log button See Figure 57 for details Revision 2 2 65 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide intel Integrated BMC Web Console System Information Server Health Configuration Server Health This section shows you data related to the server s health such as sensor readings and the event log Remote Control a LOGOUT REFRESH Q HELP Sensor Readings Event Log Power Statistics Event Log Below is a table of the events from the system s event log You can choose a category from the pull down box to filter the events and also sort them by clicking on a column header Select an event log category All Events 2 4 182 06 15 2011 12 03 55 181 06 15 2011 12 03 54 180 06 15 2011 12 0
31. Intel Integrated BMC Web Console Options On an EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families you have an additional option to Force enter BIOS Setup on a reset See Figure 83 for details inte Integrated BMC Web Console Y J I rr System Information Server Health Configuration Remote Control c LOGOUT REFRESH HELP c B Remote Control ET This section allows you to remotely monitor and control the server Power Control and Status Console Redirection The current server power status is shown below To perform a power control operation select one of the options below and press Perform Action Server Power Control Host is currently ON Virtual Front Panel m nd 9 Reset Server 7 Force enter BIOS Setup Power OFF Server Graceful Shutdown Power ON Server Power Cycle Server Perform Action Figure 83 Remote Control Server Power Control Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families Revision 2 2 95 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 74 3 Virtual Front Panel Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families On EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families this page can be used just like t
32. Module 4 and Integrated BMC Web Console User Guide Table of Contents 1 2 3 4 5 itroduc UoN an a eape an doeuenduecmasy ous camwensenaceteameuceuteeesseeased 1 1 1 DESERT 1 1 2 Ez dns dre 1 1 3 SAEY NOMA ON e E a 2 1 4 SUDDOFE IMTONMAU OM reann S ai 6 1 5 Warani TO ello cosa ia E atte latiauanelianncuaieisamunasieaticaniaiaeninins 6 Intel Remote Management Module 4 Overview ccena 7 2 1 Intel RMMA Lite and Intel Dedicated Server Management NIC 7 2 2 Mte RMM4 TF OBULOS omite reete detur ot te a a 8 2 9 Supported Operating Systems and Internet Browsers eeeeeseeesse 8 2 3 1 DSI Cl Sy Sl SN enia a a added A cadre Dc teen tai Tb ndun ade 9 2B SR MEME CT el IRR EOD DE 9 Hardware Installations and Initial Configuration sss 10 3 1 Betore You Bogi QN RI T IT TT 10 3 2 Tools and Supplies Necdet 10 3 3 Moa EE 10 3 3 1 Installation of Intel RMMA Lite on Intel Server Boards e 10 3 3 2 Installation of the Intel Dedicated Server Management NIC on an Intel Rack Server OVySIOITI aequa fusus asi tuus a a lie oni DE a nu Ente nah retrace nes 12 3 3 9 Installation of the Intel Dedicated Server Management NIC on an Intel Pedestal IIa hel M TET ET Um m 16 3 3 4 Installation of the Intel Dedicated Server Management NIC on a Third Party Pedestal GMaSSIS ex cxssecnssaeennu
33. N Bal Ascrrvcnenuashiiatiiancitnnlodsinmtevencaunsunicudd Dried qe Dire a EV En osa dua 53 Figure 47 System Information Page on S1200BTL platforms eeeeeeeseesssssssss 54 Figure 48 System Information Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families seeeeeeseeeeeereeeeennnn n 55 Figure 49 System Information FRU Information Page cccccsescecseeeeeseeeeeeseeeeeseeeeesseeeeesaaeees 56 Figure 50 System Information System Debug Log Page eeeeeeeeeeeeee 57 Figure 51 System Debug Log Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Familie s cccccccccccecseseeeecseeeeesseeeeeeseeeeeeeseaeeeeeeeas 59 Figure 52 System Information DIMM Information Page seseeseeeeeeeeeeeree 61 Figure 53 System Information CPU Information Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 62 Figure 54 Server Health Sensor Readings Page Thresholds not displayed 63 Figure 55 Server Health Sensor Readings Page Thresholds displayed 64 Figure 56 Server Health Event Log Page on S1200BTL platforms ssssussss 65 Figure 57 Server Health Event Log Page on EPSD Platforms Based on Intel
34. OW fea EET 30 Figure 20 IDA Configure Server Set Up Users window cccccseececeeeeeeeeeeeeeeeeeeeaeeeeeseeeeeeenas 31 Figure 21 IDA Configure Server Edit User Information window eese 32 Figure 22 IDA Configure Server Apply Configuration window cccccsecececsseeeeeeeeeeeeeseeeeeeeeeas 33 Figure 23 IDA Configure Server Applying Configuration progress window 34 Figure 24 IDA Configure Server Restart Server cccccccccseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseaeeeeeseas 35 Figure 25 Internet Explorer 8 displaying encryption key length seesesssssse 37 Revision 2 2 vil List of Figures Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Figure 26 Intel Integrated BMC Web Console Login Page seee 38 Figure 27 Integrated BMC Web Console Home Page ccccccseeeeeeceeeeeeeseeeeeeeeeeneeeeseeneeeeseas 39 Figure zo Launching Ine Online Melp tice esi eS ERE touc b Ra Rid ERAN A 41 Figure 29 Logging Out of Integrated BMC Web Console Step 1 eeseeuesesssse 42 Figure 30 Logging Out of Integrated BMC Web Console Step 2 seseeeesssssse 42 Figure 31 Remote Control Console Redirection Page cccccccsseccceseeeeceeeeeeeeeseeeeeeeseaeeeeseas 43 Flaure 92 Remote Gornsole ia oe adero E e ui sunu a a tuU ee ee 44
35. Remote Management Module 4 and Integrated BMC Web Console User Guide Hardware Installations and Initial Configuration 3 34 Installation of the Intel Dedicated Server Management NIC on a Third Party Pedestal Chassis The following are steps should be used when installing the Dedicated Server Management NIC module on a third party pedestal chassis 1 Ensure that AC power has been removed from the system and that you have waited at least 10 seconds after removing power 2 Attach the metal fastening bracket to Intel Dedicated Server Management NIC module AF003756 Figure 11 Attaching the bracket to Intel Dedicated Server Management NIC module 3 Secure the metal fastening bracket with NIC module to PCI slot bracket with two screws as shown in Figure 12 This will align the RJ 45 with the opening in the PCI slot bracket Revision 2 2 19 Hardware Installations and Initial Configuration Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Figure 12 Mounting the Intel Dedicated Server Management NIC module to the PCI Slot bracket 4 Attach the cable to the cable connector on the Intel Dedicated Server Management NIC module as shown in Figure 13 A Mount the PCI slot bracket with NIC module to the 3rd chassis and secure with screw as shown in Figure 11 B Attach the cable to the RMM4 NIC connector J5C1 on the server board as shown in Figure 13 C Caution Care should be used when attach
36. URIT Lorsque vous ouvrez le boitier pour acc der l int rieur du syst me suivez les consignes suivantes 1 Mettez hors tension tous les p riph riques connect s au systeme 2 Mettez le syst me hors tension en mettant l interrupteur g n ral en position OFF bouton poussoir 3 Debranchez tous les cordons d alimentation c a du syst me et des prises murales 4 Identifiez et d branchez tous les cables reli s aux connecteurs d E S ou aux acces derri re le syst me 5 Pour pr venir les d charges lectrostatiques lorsque vous touchez aux composants portez une bande antistatique pour poignet et reliez la la masse du systeme toute surface m tallique non peinte du boitier 6 Ne faites pas fonctionner le syst me tandis que le boitier est ouvert Le microprocesseur et le dissipateur de chaleur peuvent tre chauds si le syst me a t sous tension Faites galement attention aux broches aigu s des cartes et aux bords tranchants du capot Nous vous recommandons l usage de gants de protection Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precauci n de este documento antes de realizar cualquiera de las instrucciones Vea Inte Server Boards and Server Chassis Safety Information en el CD Resource y o en http www intel com support motherboards server sb cs 010770 htm 4 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide In
37. User Step by step instructions to enable a user for the RMM4 1 Set password for BMC user 2 root by typing syscfg u 2 root p sswOrd password is p ssw0rd in this example 2 Enable the BMC user 2 on LAN channel 3 by typing syscfg ue 2 enable 3 3 Enable admin privilege and payload type to SOL KVM for the BMC user 2 on LAN channel 3 by typing evecto gu p Z 3 admin sol tkvm 44 2 Configuring IP address e Set static IP address and subnet mask on LAN channel 3 by typing syscfg le 3 static STATIC IP SUBNET MASK gt e If needed set the default gateway on LAN channel 3 by typing syscfg lc 3 12 DEFAULT GATEWAY IP e Set DHCP IP address source on LAN channel 3 by typing syscfg le 3 dhcp 44 3 Configuring Serial Over LAN e f needed Serial Over LAN SOL can be enabled on LAN Channel 3 by typing syscfg sole 3 Enable Admin BAUD RATE RETRY COUNT RETRY INTERVAL IN MILLISECONDS 36 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Getting Started with Intel RMM4 Operation 5 Getting Started with Intel RMM4 Operation The Intel RMM4 module features remote KVM access and control via LAN or Internet The Intel Integrated BMC Web Console is part of the standard BMC firmware Server Management Software The Integrated BMC Web Console feature is used to access the remote KVM This section describes both the interfaces and how to use them The interfa
38. Web Console User Guide Intel Integrated BMC Web Console Options The following table lists the options available in this page Table 13 Configuration LDAP Settings Options ENL NEM EN Enable LDAP Authentication Check this box to enable LDAP authentication then enter the required information to access the LDAP server IP Address The IP address of LDAP server IP Address made of 4 numbers separated by dots as in XXxX XXX XXX XXX xxx ranges from 0 to 255 First xxx must not be O The searchbase of the LDAP server for example dc my domain dc com Bind Password Authentication password for LDAP server the password must be at least 4 characters long Bind DN The Distinguished Name of the LDAP server e g cn Manager dc my domain dc com Save button Click to save the current settings Revision 2 2 77 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 7 3 6 VLAN Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families On EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families this page is used to enable and configure the VLAN private network settings on the selected server management LAN channels LN i System Information Server Health Configuration Remote Control c LOGOUT REFRESH 2 HELP Configuration Use these pages to configure various setting
39. Xeon Processor E5 4600 2600 2400 1600 1400 Product Families sseeeseeeeseeeeeseeeeeeeeee 66 viii Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide List of Figures Figure 58 Server Health Power Statistics Page ccccccccssescececeeeeeceseeeeeeseeeeeeeseeeeeeeeseeeeeeeas 67 Figure 59 Configuration Network Settings Page on S1200BTL platforms 68 Figure 60 Configuration IPv4 Network Settings Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 69 Figure 61 Configuration IPv6 Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Familie s ccccccccccccseeeeeeceeeeeeeseeeseesseeeeeseaeeeeeeeas 71 Figure 62 Gonbugiratom User List Page mica e er to or o te ete bo bcne 73 Figure 63 Configuration Users Add User Page cccccccccsseceeeseeseeeeseeeeeeeseeaeceeseeaeeeeseaeeeeeeas 74 Figure 64 Configuration Users Modify User Page ccccccccccceeeeeceeeeeeseeeeeseeeeeseeseessaeeeesaaeees 74 Figure 65 Configuration Login Security Settings Page on S1200BTL platforms 75 Figure 66 Configuration Login Security Settings Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 76 Figure 67 Con
40. access the inside of the system follow these steps 1 Turn off all peripheral devices connected to the system 2 Turn off the system by pressing the power button 3 Unplug all AC power cords from the system or from wall outlets 4 Label and disconnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling components 6 Do not operate the system with the chassis covers removed A microprocessor and heat sink may be hot if the system has been running Also there may be sharp pins and edges on some board and chassis parts Contact should be made with care Consider wearing protective gloves Wichtige Sicherheitshinweise Lesen Sie zunachst samtliche Warn und Sicherheitshinweise in diesem Dokument bevor Sie eine der Anweisungen ausf hren Beachten Sie hierzu auch die Sicherheitshinweise zu Intel Serverplatinen und Servergeh usen auf der Ressourcen CD oder unter http www intel com support motherboards server sb cs 010770 htm SICHERHEISMASSNAHMEN Immer wenn Sie die Gehauseabdeckung abnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripheriegerate aus Schalten Sie das System mit dem Hauptschalter aus 2 3 Ziehen Sie d
41. age on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 7 3 9 1 Mouse Mode Setting Other Mode Description This mode should only be used for a SLES 11 OS installation and once this has been completed the Mouse Mode Setting should be changed to the suggested Relative Mode for use within the SLES 11 OS In this mode the KVM window will be maximized to the full screen Note that the windows resizing button in the top right corner is grayed out To use the mouse within the KVM window you must press ALT C The first time that Alt C is pressed the mouse should appear close to the center of the window Pressing Alt C after that Revision 2 2 83 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide will switch between using the mouse within the KVM window and using the mouse on your host system The mouse in the KVM window will remain in the last position that it was at when the operation is switched between the KVM Window to the host system and then back to the KVM window There is a reminder of using Alt C key in the Remote Console control bar to the left of the keyboard macros See Figure 74 for details During installation the mouse response in the KVM will be slow This is normal and expected Note If the top bar of the KVM window is double clicked the window will be resized If this occurs Since there is no resize window butto
42. agement NIC module in an Intel Server System P4304BTLSHCN PA304BTLSFON sssseeesesseesenne nennen nennen hann nn nans 17 Figure 10 Adding the Intel Dedicated Server Management NIC module in an Intel Server System P4xxxCP family and P4xxxSC family ccccccccceeeceeceeeeeeeseeeeseeseeeeeeeseeeeeeeseeeeeeeeeas 18 Figure 11 Attaching the bracket to Intel Dedicated Server Management NIC module 19 Figure 12 Mounting the Intel Dedicated Server Management NIC module to the PCI Slot IF AGK el ETE TOTNM 20 Figure 13 Adding the Intel Dedicated Server Management NIC module on a 3rd Party Chassis21 Figure 14 Server Management BMC LAN Configuration on S1200BTL 24 Figure 15 Server Management BMC LAN Configuration on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 26 Figure 16 IDA Configure Server Communication Options Window eeeeeeeses 27 Figure 17 IDA Configure Server Communication Options Window No Dedicated Server Management NIC Installed 43 trot tene e eoa tee ee Renee eed han aca eec fece edes 28 Figure 18 IDA Configure Server Configure LAN Channel 3 Intel RMM4 DMN IP Address from a DHCP Serner WIIGQOW s eeeosactuutuu sae auk tcp tiunt toss anus qun Pac e ASENA ERE 29 Figure 19 IDA Configure Server Configure LAN Channel 3 Intel RMM4 DMN Static IP Addres SWI
43. ard Shutdown L Log Event SSL Remote Session watts Mouse Mode Use Policy Suspend Periods 5 Yes 9 No Keyboard Macros Save Delete Cancel Alerts Alert Email Node Manager Figure 79 Configuration Node Manager Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families The following table lists the options allowing you to view add and edit the Node Manager Power Policies Table 20 Configuration Node Manager Options This table lists the currently configured policies Selecting an item Node Manager Power Policies from the table will populate the editable fields in the settings section below The policy number to add edit delete Valid range is 0 255 In the policy table policy numbers with an asterisk are policies Policy Number set externally using a non platform domain Changing parameters on these policies will not affect their triggers trigger limits reporting periods correction timeouts or aggressive CPU throttling settings 90 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options NENNEN es Se Enabled check box Check this box if the policy is to be enabled immediately Check this box to enable a hard shutdown if the policy is exceeded Mare em ECO Mn check Dox and cannot be corrected within the correction timeout period Check this box to enable the node manager to
44. b n m amp ww v9 cm ar Ax LA ja e cm yj 0 jon Figure 39 Remote KVM Soft Keyboard Buttons clicked on the Soft Keyboard window get sent as key strokes to the remote target The Soft Keyboard is also a convenient way to see the exact layouts supported for the local keyboards since they are the same The Soft Keyboard language layout follows the local keyboard language setting when the default Keyboard gt Soft Keyboard gt Follow Local option is selected This can be manually overridden by selecting a language Revision 2 2 49 Remote Console KVM Operation Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Note The Soft Keyboard keystrokes get retranslated by the remote target OS just like the local physical keystrokes and are subject to the same mismatched configuration issues 6 3 8 Remote Console Mouse Menu Click Mouse to open the Mouse menu with options to perform tasks as shown in Figure 40 H Show Cursor Mouse Mode Figure 41 Remote Console Mouse Menu on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families IM Show Cursor I Relative Mode J Other Mode Figure 42 Remote Console Mouse Menu Mode selection on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families The Mouse submenu offers two or three options e Show Cursor This option toggles the cursor display in the Remot
45. c system Table 3 Intel Rack Server Systems Chassis mounted Intel Dedicated Server Management NIC RMM4 NIC Connector Locations Intel Server RMM4 NIC Connector Cable amp Bracket System Reference Designator Required R1304BTLSFAN R1304BTLSHBN J5C1 Yes Figure 6 R20005C Family ves Figure 6 R1000GZ GL Family 2 Push out and remove the metal cover on the chassis where the NIC RJ 45 receptacle will align R1000BB Family J3B2 Figure 7 R2000BB Family Caution Carefully remove the metal cover with pliers directly removing it with finger has potential risk 3 Ifa cable and bracket are required see Table 3 use the following steps a Attach the metal fastening bracket to Intel Dedicated Server Management NIC module as shown in Figure 4 12 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Hardware Installations and Initial Configuration AF003756 Figure 4 Attaching the bracket to Intel Dedicated Server Management NIC module b Attach the cable to the cable connector on the Intel Dedicated Server Management NIC module as shown in Figure 5 Caution Care should be used when attaching or removing this cable Mishandling the cable could cause damage AF003758 Figure 5 Attaching the cable to Intel Dedicated Server Management NIC module c Attach the cable to the cable connector on the Intel Dedicated Server Management NIC module Mount the NIC module
46. ces are accessed using TCP IP protocol 5 1 Before You Begin For initial setup information refer Chapter 4 Before you log in you must enable the intended user The examples in this chapter will use user root but other usernames and passwords could be used The Intel RMM4 enabled advanced features may be accessed using a standard Java enabled web browser You may use the HTTP protocol or a secure encrypted connection via HTTPS configurable in the embedded web server 5 1 1 Client Browsers In order to access the web console using a securely encrypted connection you will need a browser that supports the HTTPS protocol Strong security is only assured by using a Cipher Strength encryption of 128 Bit Some older browsers may not have a strong 128 Bit encryption algorithm If you are using Microsoft Windows Internet Explorer 7 0 or higher you can verify strong encryption by opening the Help About menu to read about the key length that is currently activated Figure 25 shows the dialog box presented by the Internet Explorer 8 0 About Internet Explorer Windows Internet Explorer Version 8 0 7600 16385 Cipher Strength 256 bit Product ID 00392 918 5000002 85092 Update Versions 0 Warning This computer program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and w
47. clicking the HELP button at the right side of the horizontal menu e When the Web Console is working on current user request a busy indicator bar appears as shown in Figure 46 EN NM OMNI Figure 46 Busy Indicator Bar e Not all of the following sections are used by or directly related to the RMM4 enabled features but have been added here for completeness Revision 2 2 53 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 7 1 System Information Tab The System Information tab contains general information about the system as explained in the following sub sections Click on the System Information tab to select the various pages By default the Integrated BMC Web Console home page opens the System Information page 7 1 1 System Information page The System information page displays a summary of the general system information This includes the power status and the version of firmware Figure 47 shows the details for a S1200BTL system intel Integrated BMC Web Console LC i System Information Server Health Configuration Remote Control e LOGOUT REFRESH HELP a System Information This section contains general information about the system Summary System Information System Information FRU Information Host Power Status Host is currently ON RMM Status Intel R RMM installed Device BMC Available Yes BMC FW Build Ti
48. ct Relative Mode to have the calculated relative mouse position displacement sent to the server Use this mode for other Linux versions such as SUSE SLES and older versions of Red Hat RHEL 5 x For best results server OS mouse acceleration threshold settings can be reduced or use mouse calibration in the remote console window e Other Mode Select Other Mode to have the calculated displacement from the local mouse in the center position sent to the server Under this mode ALT C should be used to switch between Host and client mouse cursor Use this mode for SLES 11 Linux OS installation See section 7 3 9 1 for more details on this mode Click Save to use selected mode intel Integrated BMC Web Console m Tus 4 A a HELP ind E j System Information Server Health Configuration Remote Control e LOGOUT REFRESH Configuration Use these pages to configure various settings such as alerts users or network Mouse Mode Setting IPv4 Network Select the mouse mode to use from the options below and press the Save button IPv Network Users Current Mouse Mode Logn amp amp Absolute Mode Recommended when server OS is Windows or Red Hat Fedora Linux LDAP Relative Mode Recommended when server OS is SLES Linux Other Mode Recommended when SLES 11 OS Installation Remote Session Mouse Mode Keyboard Macros Alerts Alert Email Node Manager Figure 73 Configuration Mouse Mode Setting P
49. ction USB Key Emulation Type Select Floppy or Hard Disk emulation Save button Click to save any changes On an EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families you can select the Encryption mode and separately enable disable keyboard mouse and Media encryption See Figure 71 for details 80 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options p i C E f f E 4 m M System Information Server Health Configuration Remote Control Ca LOGOUT REFRESH 0 HELP E AM Configuration Use these pages to configure various settings such as alerts users or network Remote Session IPv4 Network The following options allow the user to enable or disable encryption on KVM or Media data during a redirection session IPv6 Network Users KVM Encryption None v Logi ogn Keyboard Mouse Only Enable LDAP Media Encryption Enable VLAN dini SSL USB Key Emulation Type Floppy hd Remote Session Save Mouse Mode Keyboard Macros Alerts Alert Email Node Manager Figure 71 Configuration Remote Session Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families The following table lists the options allowing you to enable or disable encryption on KVM or media data and the USB Key Emulation type selection used during a re
50. destal Server Systems with Chassis mounted Intel Dedicated Server Management NIC RMM4 NIC Connector Locations ccccceeeeceeeeeeeeeeeeeeeeeeseeeeeeeaeees 17 Table 5 Intel Server Boards RMM4 NIC Connectors eene 21 Table 6 Integrated BMC Web Console home page tabs ccccccccseeeeeeeeeeeeseeeeeseeeesseneeesaaes 39 Table 7 Horizortal Toolbar BUTTONS 26 occa ance i ute ta Toe EUR Ee eem ie ae t ee ee E munie e estos 40 Table 8 System Information Details uisi carius nOD CP r ita a ut ea o coru ba etu 54 Table 9 Server Health Sensor Readings Options cccccccseccccseececceseeeseeeeeeseseeeseueeeeseeeetanes 64 Table 10 Server Health Event Log Options on S1200BTL platforms 65 Table 11 Configuration IPv4 Network Settings Options ccccccccccseeeeeeeseeeeseeeeeseeeeesseeeesaaes 69 Table 12 Configuration IPv6 Network Settings Options cccccccccccescceseeeeeeseseeeseeeetseeeesanes 72 Table 13 Configuration LDAP Settings Options cccccccccssececeseeeeeeeeeeeeeeeeeeeeeeseuseetseaeeesanes 77 Table 14 Configuration VLAN Settings Options ccccccccccsseeeeceeeeesseeeeeseeeeeeseeeeeseaeeesseeeeesaaes 78 Table 15 Configuration Remote Session Options ccccccssecceceeseecceeeeeteeeceeseneeessueeetseeeetanes 80 Table 16 Configuration Remote Session Options ccccccseeececeesceeeeeceetaeeceeseeeeeseee
51. different passwords e System Debug Log file can be viewed by Intel partners who have signed an NDA with Intel and its contents are restricted to specific data items specified in this with the exception of the BMC syslog messages and power supply black box data e System amp BMC Debug Log file is strictly for viewing by Intel engineering and may contain BMC log messages that is syslog and other debug data that Intel FW developers deem useful in addition to the data specified elsewhere in this document 60 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 1 4 DIMM Information Page The DIMM Information page displays information on DIMM modules installed on the host system See Figure 52 for details intel Integrated BMC Web Console b System Information Server Health Configuration Remote Control RI LOGOUT 2 REFRESH HELD T System Information This section contains general information about the system v DIMM Information stem Information The list below shows the current list of system DIMM FRU Information Number of system DIMM 2 1jnosbcs DIMM Information Stot Number Size gt Type Speed A1 1024 DOR3 1333 Micron 0123456789 D64F 4845 9JSF 1287242 1G4F 1 B1 1924 DOR3 1333 Micron 0123456789 DG4F 4347 9JSF 1267242 1G4F 1 Figure 52 System Information DIMM Information Page Revision 2 2 61 Intel
52. direction The media redirection feature is intended to allow system administrators or users to mount a remote IDE or USB CD ROM floppy drive or a USB flash disk as a remote device to the server Once mounted the remote device appears just like a local device to the server allowing system administrators or users to install software including operating systems copy files update BIOS and so on or boot the server from this device e KVM Automatically senses video resolution for best possible screen capture high performance mouse tracking and synchronization It allows remote viewing and configuration in pre boot POST and BIOS setup 2 3 Supported Operating Systems and Internet Browsers The Intel RMM4 enabled features run independent of the host operating system on the server where it is installed except during Remote Console KVM connections During Remote Console connections the Keyboard Mouse and Video of the console system operate just as if you were at the server where the Intel RMMA is connected During Remote Console connections the interaction with the host operating system limits the support to operating systems that have been validated Those operating systems are listed in the following sub sections 8 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Remote Management Module 4 Overview 2 3 1 Server System The following operating systems are supported on the managed
53. direction session Table 16 Configuration Remote Session Options Disable or select encryption mode on KVM or Media data during a redirection session Choose any one from the supported encryption techniques None Stunnel RC4 or KVM Encryption mode AES Note KVM and Media encryption are enabled by default Note Disabling encryption can improve performance of KVM or Media redirection If KVM Encryption is set to None the Keyboard amp Mouse data can still be encrypted using Blowfish encryption Keyboard Mouse Only Note This option has the least performance impact while still encrypting the most important data Enable Disable encryption of Media data during a redirection session Media Encryption Note Disabling encryption can improve performance of KVM or Media redirection Revision 2 2 81 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Mm ooo Tk USB Key Emulation Type Select Floppy or Hard Disk emulation Save button Click to save any changes 7 3 9 Mouse Mode Page Use this page to select the Mouse Mode used during a Remote KVM session On a S1200BTL system the Redirection Console handles mouse emulation from local window to remote screen in either of two methods Figure 72 shows the details e Absolute Mode Select to have the absolute position of the local mouse sent to the server Use this mode for Windows OS e Relative M
54. e Console window It does not affect the remote system cursor Shortcut is ALT C e Mouse Calibration This option is used to detect the threshold and acceleration settings on the remote system and set the local client s mouse settings accordingly It only applies when in Relative Mouse Mode selected on the web page Configuration gt Mouse Mode Absolute Mouse Mode does not require calibration Shortcut is ALT T e Mouse Mode This option is only available on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families See Figure 41 This allows you to select the mouse mode being used You can select Absolute Relative or Other as shown in Figure 42 For a description of these modes see section 7 3 9 Note that the functionality of this option is the same as changing then saving the mode on the Mouse Mode page Any selections that you make will be saved for the next time when the remote console window is opened 50 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Remote Console KVM Operation Relative Mode Mouse Calibration Procedure 1 If the remote mouse and local mouse cursor are not in synch start mouse calibration by selection the Mouse Calibration menu item or pressing ALT T In this step the mouse threshold settings on the remote server will be discovered The local mouse cursor is displayed in RED color and the remote cursor is part of the remote vid
55. e IP Address is made of 4 numbers separated by dots as in Xxx XXX XXX XXX e xxx ranges from O to 255 e First xxx must not be O Sender Address The Sender address string to be put in the From field of outgoing Alert emails The hostname of the local machine that is generating the alert It is put into the outgoing Alert email Local Hostname e The Local Hostname is a string of maximum 31 alpha numeric characters e Space Special Characters are not allowed Save button Click to use selected setup Revision 2 2 n 89 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 7 3 13 Node Manager Power Polices Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families On EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families this page is used to view add and configure the Node Manager Power Policies intel Integrated BMC Web Console System Information Server Health Configuration Remote Control e LOGOUT REFRESH 0 HELP T 3 Configuration Use these pages to configure various settings such as alerts users or network AF Node Manager Power Policies IPv4 Network Use this page to set Node Manager Power Policies IPv6 Network LA S5 i Users Login AM 70 Add Edit Node Manager Policies LDA Policy Number VLAN Enabled H
56. e IP address Disable LAN Channel Will set the IP address Subnet Mask and Default Gateway to 0 0 0 0 IP Address If configuring a static IP enter the requested address subnet mask and gateway in Subnet Mask the given fields Gateway IP Address made of 4 numbers separated by dots as in XXX XXX XXX XXX Xxx ranges from 0 to 255 First xxx must not be 0 Primary DNS Server If configuring a Dynamic IP enter the Primary and Secondary DNS servers Secondary DNS Server Save button Click to save any changes made 70 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 3 2 IPv6 Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families The IPv6 settings page is used to enable and configure the IPv6 network settings You can also enable and configure LAN Failover on this page See Figure 61 for details intel Integrated BMC Web Console System Information Server Health Configuration Remote Control Configuration Use these pages to configure various settings such as alerts users or network IPv6 Network Settings IPv4 Network You can view and modify the IPv6 network settings on this page Select whether to obtain an IP address automatically or es manually configure one IPv6 support must be enabled prior to it s configuration Users Enable LAN Failover Login LAN Cha
57. e UserlD 1 anonymous may not be renamed or deleted e UserlD 2 root may not be renamed or deleted nor can the network privileges of UserlD 2 be changed e User Names cannot be changed To rename a User you must first delete the existing User and then add the User with the new name To delete a user select the user in the list and click Delete User To add a user select an empty slot in the list and click Add User This allows you to set the User Name Password and Network Privileges as shown in Figure 63 Revision 2 2 73 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide intel Integrated BMC Web Console i mI f EJ D j i a 7 f P dia System Information Server Health Configuration Remote Control e LOGOUT REFRESH 3 HELP m ECT Configuration E L wo Use these pages to configure various settings such as alerts users or network Add New User Network Enter the information for the new user below and press Add Press Cancel to return to the user list Users User Name Login LDAP Password SSL Confirm Password Remote Session Network Privileges Administrator v Mouse Mode Add Cancel Keyboard Macros Alerts Alert Email Figure 63 Configuration Users Add User Page To modify a user select a user in the list and click Modify User This allows you to change the Password Enable Access and change Network Privileges a
58. e chassis Attach the cable to the RMM4 NIC connector as specified in Table 4 on the server board 16 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Hardware Installations and Initial Configuration Caution Care should be used when attaching or removing this cable Mishandling the cable could cause damage Table 4 Intel Pedestal Server Systems with Chassis mounted Intel Dedicated Server Management NIC RMM4 NIC Connector Locations Intel Server RMM4 NIC Connector System Reference Designator P4304BTLSHCN P4304BTLSFCN aG P4308CP4MHEN P4308CP4MHGC J1C7 Figure 10 P4208CP4MHGC P4304SC2SFEN P4304SC2SHDR J1C1 Figure 10 P4308SC2MHGC AO j DT l STIR 1 Wee Uli cl S iss Ht M ig j CE UTR Mu SS ig Ml aaa I li ll TTA TTE AF003785 Figure 9 Adding the Intel Dedicated Server Management NIC module in an Intel Server System P4304BTLSHCN P4304BTLSFCN Revision 2 2 17 Hardware Installations and Initial Configuration Intel Remote Management Module 4 and Integrated BMC Web Console User Guide we LA AF004507 Figure 10 Adding the Intel Dedicated Server Management NIC module in an Intel Server System P4xxxCP family and P4xxxSC family 5 Replace the chassis cover attach AC power and connect a network cable to the Intel Dedicated Server Management NIC module 18 Revision 2 2 Intel
59. e sitting directly in front of the screen of his her remote system This means the keyboard and mouse can be used in the usual Way 6 1 Launching the Redirection Console The Remote Console is the redirected keyboard video and mouse of the remote host system where the Intel RMM4 module is installed Launch the remote console KVM redirection window from this page Note If using Windows Internet Explorer Smart Screen is enabled and the system is on a network with no direct connectivity to the internet it may take an extremely long time to open a KVM window inte Integrated BMC Web Console System Informaton Server Health Configuration Remote Control ci LOGOUT REFRESH Remote Control This section allows you to perform various remote operations on the server such as launching the remote console Console Redirection Console Redirection Press the button to launch the redirection console and manage the server remotely Server Power Contro Launch Console Figure 31 Remote Control Console Redirection Page Revision 2 2 43 Remote Console KVM Operation Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Click the Launch Console button to launch the redirection console and manage the server remotely When the Launch Console button is clicked a pop up window is opened to download the Java Network Launch Protocol jviewer jnlp file That in turn downloads the standalone Java applica
60. e some time for the diagnostics to run Once the debug log dump is finished you can click the diagnostic filename to save the results as a zip file on your client system The file can then be sent to your system manufacturer or an Intel support engineer for analysis intel Integrated BMC Web Console System Information Server Health Configuration Remote Control A LOGOL i V System Information This section contains general information about the system Administrators may use this feature to collect data system wide System Information System Diagnostics Last Test Run Never L FRU Information System Diagnostics Run DIMM Information Figure 50 System Information System Debug Log Page A list of data that may be captured using this feature includes but is not limited to Platform sensor readings This includes all readable sensors that can be accessed by the BMC FW and have associated SDRs populated in the SDR repository This does not include any event only sensors All BIOS sensors and some BMC and ME sensors are event only meaning that they are not readable using an IPMI Get Sensor Reading command but rather are used just for event logging purposes SEL The current SEL contents are saved in both hexadecimal and text format Revision 2 2 57 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User
61. eesseeeetanes 81 Table 17 Macro Non printable Key Names cccccccceeececeeceeeecesseeeeseeceeaueesseeeeseueesseeeeseeeesaes 86 Table 18 Configuration Alerts Options cccccccccccescceceeceeceeeeeceuecesseeeeeseseeeeseueeeseuseetseneeetanes 87 Table 19 Configuration Alert Email Options cccccccccssecccseseeeceeeeeeeeeeesseeceeseeeeseueeetseeeetanes 89 Table 20 Configuration Node Manager Options c cccccccsssececeeeeeceeeeeesaeeceeseeeeeseeeesseaeeesanes 90 Table 21 Remote Control Power Control Options ccccccseccecseececeeeeeeseeeceeseneeeseueeesseeeesanes 94 Table 22 Remote Control Virtual Front Panel Options eeeeseeeeeeeeseeeeseeeee 96 X Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide List of Tables This page is intentionally left blank Revision 2 2 xi Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Introduction 1 Introduction This User Guide describes how to use the Intel Remote Management Module 4 hereinafter referred to as Intel RMM4 and the Integrated BMC Web Console It provides an overview of the features of the Web console and the RMM4 module along with instructions on how to set up and operate the Intel RMM4 The Intel Integrated BMC Web Console provides both exceptional stability and permanent availability independent of the present state of the server s
62. en StromanschluBstecker Ihres Systems aus der Steckdose 4 Auf der R ckseite des Systems beschriften und ziehen Sie alle AnschluBkabel von den I O Anschl ssen oder Ports ab 5 Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD ber blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Revision 2 2 3 Introduction Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Der Mikroprozessor und der K hler sind m glicherweise erhitzt wenn das System in Betrieb ist AuBerdem k nnen einige Platinen und Geh useteile scharfe Spitzen und Kanten aufweisen Arbeiten an Platinen und Geh use sollten vorsichtig ausgef hrt werden Sie sollten Schutzhandschuhe tragen A BEETq CEPT tEHTEA I BEL TER BEA ICR PAP TERRE ee BI Resource CD CE EG Bi AIE http www intel com support motherboards server sb cs 010770 htm LH nteP Server Boards and Server Chassis Safety Information Intel AR 25 EAS ARS SR LAG zh HM Consignes de s curit Lisez attention toutes les consignes de s curit et les mises en garde indiqu es dans ce document avant de suivre toute instruction Consultez Inte Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez vous sur le site http www intel com support motherboards server sb cs 010770 htm CONSIGNES DE S C
63. eo screen Both the cursors will be IN SYNCH in the beginning Please use number pad or keys to change the threshold settings until both the cursors go out of synch Please detect the first reading on which cursors go out of synch Once detected use ALT T to save the threshold value In this step the mouse acceleration settings on the remote server will be discovered The local mouse cursor is displayed in RED color and the remote cursor is part of the remote video screen Both the cursors will be OUT OF SYNCH in the beginning Please use number pad or keys to change the acceleration settings in steps of 1 or use Alt or Alt keys to change the acceleration settings in steps of 0 1 until both the cursors are in synch Please detect the first reading on which cursors are in synch Once detected use ALT T to save the acceleration value 6 3 4 Remote Console Options Menu Bandwidth H AutoDetect Keyboard Mouse Encryption O 356 Kbps 3 512 Kbps 2 4 Mbps O 10 Mbps amp 100 Mbps Figure 43 Remote Console Options Menu Using this menu you can do the following e Bandwidth Changing the bandwidth setting affects low level connection protocol parameters like fragment size and timeouts If you experience performance problems when operating over a slow connection such as a modem the Bandwidth setting may need to be adjusted Use the Auto Detect option to find the correct setting for your co
64. er Fealil clo RR I TTE 63 7 2 1 Sensor neadinds Padel sessi aed iE E demie Uc ined sup Lets a AOE 63 7 2 2 Event Log emm M M M 65 7 23 POWER SIA SHCS FP aO arana ot nus sae aa eet cla cce cq um 67 13 Se aec a 68 7 3 1 Network or IPv4 Network Pag e ccccsseccceseeceeeeeeeeeseeeesseeeeseeeeseeesseeesaeeeneeeenees 68 13 2 IPv6 Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families ccccccccccsesssseeeeeeceeeeeeeeeseseeeeeeeeeenas 71 7 303 DUSEISIDdO snot esu uU insu eee E MC EM iU et ene oer 73 7 3 4 Login Security Settings Page ssseeesssssessssseseee nennen nennen nnns 75 7 3 5 EDAP SetNgS Fage usce stein decane NE R A Ee EEE RANEE 76 7 3 6 VLAN Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families sseeeeeeseeeeeee eee 78 u OoOLUDIOSd Page aae dba a ae talented a et ae UU UD 79 3 9 REMOS SESSION Page entier teretes ho aun RYana etude oa estesa ere luue easet 79 7 3 9 MOUSE Mode PAG NIIT EE EO TOT 82 1310 KeyDoard Macros Page asco sese stad aids N 85 TEGAN AlENS Paganad mpm 87 Foie Alet Emal Pago essin a a a aa o 89 7 3 13 Node Manager Power Polices Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 90 Revision 2 2 V Table of Contents Intel Remote Management Module 4 and I
65. ey strokes to be interpreted correctly at the remote end the client OS the target OS and the Remote Console should all be configured for the same language layout The Remote Console Java application reverse translates local key strokes based on the selected language layout If there is a mismatch sometimes it works fine anyway otherwise it mostly works except for a few mistranslated or unresponsive keys and in some mismatched configurations most of the keys are mishandled 6 3 2 1 1 Windows Language Layouts The Remote Console supports the Windows default keyboard variants for the supported languages Under Windows the language is the current Language Bar setting initially configured in Control Panel gt Regional and Language Options gt Languages gt Text Services and Input Languages If you are using one of the supported language keyboards you don t have to manually select the language in the Remote Console as the auto detect automatically and immediately follows any Language Bar changes Manually setting the language would typically be useful if you are using a keyboard close but not identical to one of the supported ones 6 3 2 1 2 Linux Language Layouts The Remote Console supports the Linux default keyboard variants for supported languages except Russian where it is the Russian Winkeys variant The Dutch layout is Belgium in Linux Under Linux you typically select the language at the login screen it can also be
66. figuration LDAP Settings Page cccccceccccsseececeeseesseeeeeseeeeeeseeeeeseeeeessaeeeesaaeees 76 Figure 68 Configuration VLAN Settings on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families cccccecccccceseeeeeeseeeeesseeeeesseeeeeeesaenes 78 Figure 69 Configuration SSL Upload Page sirmis T 79 Figure 70 Configuration Remote Session Page on S1200BTL platforms 80 Figure 71 Configuration Remote Session Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families sse 81 Figure 72 Configuration Mouse Mode Setting Page on S1200BTL platforms 82 Figure 73 Configuration Mouse Mode Setting Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 83 Figure 74 KVM window with Mouse Other Mode selected on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 84 Figure 75 Configuring Keyboard Macros PagQe cccccseeccceceeseeeeceeeeeceseeeeeeeseeeesesseeaeeeessaaeeeeeeas 85 Figure 76 Configuration Alerts Page on S1200BTL platforms eeeeeeeseeeeesss 87 Figure 77 Configuration Alerts Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600
67. he systems front panel intel Integrated BMC Web Console System Information Server Health Configuration Remote Control Remote Control This section allows you to remotely monitor and control the server Console Redirection Server Power Control Power I Chassis ID Figure 84 Remote Control Virutal Front Panel Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families The following power control operations can be performed Table 22 Remote Control Virtual Front Panel Options EL GNE NEN Power Button Power button is used to Power ON or Power Off Reset Button Reset Button is used to reset the server while system is ON Chassis ID Button When Chassis ID button is pressed then the chassis ID LED changes to solid on If the button is pressed again the chassis ID LED turns off NMI Button At present NMI button is disabled Power LED Power LED shows system power status If LED is green then System is ON If LED is grey then System is OFF Status LED Status LED will reflect the system status LED status and It automatically sync with BMC every 60 seconds This reflects the System Status LED Chassis ID LED Chassis ID LED shows the current system chassis ID status If Chassis ID is blue then Chassis ID is Indefinite ON If Chassis ID is grey then Chassis ID is OFF 96 Revision 2 2
68. ill be prosecuted to the maximum extent possible under the law 2009 Microsoft Corporation Figure 25 Internet Explorer 8 displaying encryption key length In order to use the Remote Console KVM window of your managed server Java Runtime Environment JRE Version 6 Update 22 or higher must be installed Revision 2 2 3 Getting Started with Intel RMM4 Operation Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Note The Web Console is designed for a screen size of 1280 pixels by 1024 pixels or larger In smaller screens the browser will display slider controls to enable the user to see the full content of each web page 5 2 Logging In Enter the configured IP address of the Intel RMM4 or your configured BMC on board NIC into your web browser In order to use a secure connection type https IPaddress This will take you to the Intel Integrated BMC Web Console module login page as shown in Figure 26 intel Integrated BMC Web Console Please log in to access the device Username Password Figure 26 Intel Integrated BMC Web Console Login Page Log in by entering the username and password For example e Username root e Password superuser Click the Login button shown in Figure 26 to view the home page After the initial log in System Administrators may change passwords create new users and have full control over access to the RMM4 enabled advanced features
69. ing or removing this cable Mishandling the cable could cause damage 20 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Hardware Installations and Initial Configuration Figure 13 Adding the Intel Dedicated Server Management NIC module on a 3rd Party Chassis Table 5 Intel Server Boards RMM4 NIC Connectors Intel Server RMM4 NIC connector Board Reference Designator J5C1 J3B2 J1C7 5 Replace the chassis cover attach AC power and connect a network cable to the Intel Dedicated Server Management NIC module Revision 2 2 21 Configuring Integrated BMC Web Console and Intel RMM4 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 4 Configuring Integrated BMC Web Console and Intel RMM4 This section discusses using the Server Utilities to enable your system to use the Integrated BMC Web Console or the Intel RMMA from a new unconfigured state to an operational one When first powered on by default the Server Management BMC LAN and the Intel RMM4 have a static IP address of 0 0 0 0 The Server Management BMC LAN and the Intel RMM4 can be configured in multiple ways e Using BIOS setup e Using the Intel Deployment Assistant IDA e Using Sysconfig SYSCFG e Using IPMI commands Note You can download the IDA and SYSCFG software from the following links e IDA http www intel com p en US support highlights server ida Thi
70. intel Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Revision 2 2 January 2012 Enterprise Platforms and Services Division Revision History Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Revision History Date Revision Modifications Number February 2011 After second review Screen captures updated December 2011 20 Renamed document and added EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families December 2011 Update for new speed POR e Added AXXRMMAR January 2012 e Added description of Mouse Mode Other e Added description of KVM mouse mode selection capability i Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Disclaimers Disclaimers Information in this document is provided in connection with Intel products No license express or implied by estoppel or otherwise to any intellectual property rights is granted by this document Except as provided in Intel s Terms and Conditions of Sale for such products Intel assumes no liability whatsoever and Intel disclaims any express or implied warranty relating to sale and or use of Intel products including liability or warranties relating to fitness for a particular purpose merchantability or infringement of any patent copyright or other intellectual property right Intel products are not designed intended or a
71. ion Remote Control 9 HG y Configuration 21 Use these pages to configure various settings such as alerts users or network Login Security Settings Network You can view and modify the login security settings on this page Select how many failed login attempts occur before a user is locked out and for how long Users Login 9 Failed Login Attempts 3 LDAP User Lockout Time min 1 SSL Save Remote Session Mouse Mode Keyboard Macros Alerts Alert Email Figure 65 Configuration Login Security Settings Page on S1200BTL platforms For EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families you can also force the interface to HTTP Secure mode by selecting the Force HTTPS Enable check box See Figure 66 for details In addition the Web Session Timeout that locks the web session after a specified time of inactivity can be changed from the default of 30 minutes 1800 seconds by entering a new value for the number of seconds to wait before locking out the web session Click the Save button to save any changes Revision 2 2 75 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide inte Integrated BMC Web Console System Information Server Health Configuration Remote Control Configuration Use these pages to configure various settings such as alerts users or network Login Security Settings
72. ions in this guide to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region s in which the product is sold WARNINGS System power on off The server power button DOES NOT turn off the system power or Intel RMM4 power To remove power from the Intel RMM4 you must unplug the server AC power cord from the wall outlet Make sure the AC power cord is unplugged before you open the chassis to add or remove the Intel RMM4 Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone and communication cables Turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts ESD and handling boards Alwa
73. ks If there is a loss of functionality on the primary network controller channel it will randomly failover to any of the other network controller channels that are connected and seen by the BMC The following table lists the options available in this page Table 11 Configuration IPv4 Network Settings Options mem 00 m Enable LAN Failover Used to enable LAN Failover only available on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families Revision 2 2 69 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide LAN Channel drop down Used to select the Channel that you would like to configure the network settings box Lists the LAN Channel s available for server management The LAN channels describe the physical NIC connection on the server Intel R RMM BMC LAN Channel 3 is the add in RMM4 NIC Baseboard Mgmt BMC LAN Channel 1 is the onboard shared NIC configured for management and shared with the operating system Baseboard Mgmt 2 BMC LAN Channel 2 is the second onboard shared NIC configured for management and shared with the operating system MAC Address The MAC address of the device read only IP address radio buttons Select one of the three options for configuring the IP address Obtain an IP address automatically use DHCP uses DHCP to obtain the IP address Use the following IP address Manually configure th
74. luence the local Remote Console settings Video Keyboard Mouse Options Device Help Macros Ctrl Alt Del Alt Tab Figure 34 Remote Console Control Bar The following sub sections describe the tasks you can perform within each control 6 3 1 Remote Console Video Menu Click Video button in the Remote Console control bar to open the Remote console Video menu as shown in Figure 35 Pause Redirection Alt P Refresh Video Compression J Full Screen Figure 35 Remote Console Video Menu Using this menu you can do the following e Pause Redirection Temporarily pauses redirection of keyboard video and mouse The Remote Console window stops being updated Keyboard shortcut is ALT P e Resume Redirection Resume redirection after a pause Shortcut is ALT R e Refresh Video Refreshes the Remote Console window Shortcut is ALT E e Compression Enabling compression improves the responsiveness of the Remote Console Disabling compression maximizes the quality of the redirected video e Full Screen Toggles windowed full screen mode of the Remote Console Shortcut is ALT F e Exit Closes Remote Console 46 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Remote Console KVM Operation 6 3 2 Remote Console Keyboard Menu Click Keyboard to open the Keyboard menu with options to perform tasks as shown in Figure 36 Keyboard Language gt Soft Keyboard gt 1 Hold Right Ctri Key
75. me Apr 8 2011 12 35 25 BMC FW Rev 01 05 Boot FW Rev 00 02 SDR Package Version SDR Package 0 11 Mgmt Engine ME FW Rev 02 08 015 0 System Diagnostics DIMM Information Figure 47 System Information Page on S1200BTL platforms The System Information page has the following information about the server Table 8 System Information Details Host Power Status Shows the power status of the host on off RMM Status Indicates if the Intel RMM4 card is present Device BMC Available Indicates if the BMC is available for normal management tasks BMC FW Build Time The date and time of the installed BMC firmware 54 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options BMC FW Rev Major and minor revision of the BMC firmware Boot FW Rev Major and minor revision of the BOOT firmware SDR Package Version Version of the Sensor Data Record Mgmt Engine ME FW Rev Major and minor revision of the Management Engine firmware On an EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families you also get an Overall System Health Indication See Figure 48 for details These are a general indication of the system heath e Left Green System Ready LED e Center Amber System Fault LED e Right Blue Chassis ID LED intel Integrated BMC Web Console System Information Server Health Co
76. n the operator can use the Remote Console Control Bar to select Video and then perform a Full Screen or press Alt F operation to go to the full screen mode E Wiewer 172 24 243 44 0 fps Video Keyboard Mouse Options Device Help OTHER MOUSE MODE PRESS Alt C To Enable Local Cursor Macros Ctrl Alt Del Alt Tab Boot from Hard Disk Repair Installed System Rescue System Check Installation Media Firmware Test Memory Test Boot Options F1 Help F2 Language F3 Video Mode F4 Source F5 Kernel F6 Driver English US 800 x 600 CD ROM Default No Change the Mouse Mode to Other Mode Figure 74 KVM window with Mouse Other Mode selected on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 84 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 3 10 Keyboard Macros Page Macro buttons can be defined on this page that will appear in the upper right corner of the KVM Remote Console application window Each button is assigned a sequence of keys to execute when the button is clicked intel Integrated BMC Web Console System Information Server Health Configuration Remote Control e LOGOUT REFRESH HELP E Configuration Use these pages to configure various settings such as alerts users or network Gd E LI 1 1 Keyboard Macros Network Yo
77. ne Intel R CPU 2 30GHz Central Processor Intel Xeon 2 3 GHz 8 1V Other Populated Enabled Figure 53 System Information CPU Information Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 62 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 2 Server Health Tab The Server Health tab shows you data related to the server s health such as sensor readings the event log and power statistics as explained in the following sub sections Click on the Server Health tab to select the various pages By default this tab opens the Sensor Readings page 7 2 1 Sensor Readings Page The Sensor Readings page displays system sensor information including status health and reading as shown in Figure 54 and Figure 55 By default the sensor readings are updated every 60 seconds but this can be changed by entering a value in the Set auto refresh in seconds selection box and then pressing the Set button intel Integrated BMC Web Console System Information Server Health Configuration Remote Control Server Health This section shows you data related to the server s health such as sensor readings and the event log Sensor Readings Sensor Readings This page displays system sensor information including readings and status You can toggle viewing the thresholds for the sensors by p
78. nfiguration Remote Control LP 4 System Information This section contains general information about the system Summary System Information System Information FRU Information Host Power Status Host is currently ON RMM Status Intel R RMM installed Device BMC Available Yes BMC FW Build Time Oct 25 2011 13 40 41 BIOS ID SE5C600 86B 99 99 x036 091920111209 BMC FW Rev 00 26 2169 Boot FW Rev 01 04 SDR Package Version SDR Package 0 21 Mgmt Engine ME FW Rev 02 01 05 012 o O System Debug Log CPU Information DIMM Information Overall System Health Figure 48 System Information Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families Revision 2 2 55 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 7 1 2 Field Replaceable Unit FRU Information Page The Field Replaceable Unit FRU Information page displays information from the FRU repository of the host system See Figure 49 for details System Information Server Health Configuration Remote Control 1 x System Information FRU Information System Debug Log CPU Information DIMM Information System Information This section contains general information about the system FRU Information Chassis Inf
79. ng Started with Intel RMM4 Operation Intel Remote Management Module 4 and Integrated BMC Web Console User Guide intel Integrated BMC Web Console Logged out Please log in again to access the device Username Password Login Figure 30 Logging Out of Integrated BMC Web Console Step 2 Note Automatic Timeout If there is no user activity detected by the Web Console for 30 minutes the current session will be automatically terminated If the user has an open KVM remote console window the web session will not automatically timeout The next action attempted by the user after the automatic timeout will inform the user of the need to login again for continued access to the Web Console 42 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Remote Console KVM Operation 6 Remote Console KVM Operation The Remote Console is the redirected screen keyboard and mouse of the remote host system where the Intel RMM4 module is installed To use the Remote Console window of your managed host system the browser must include a Java Runtime Environment plug in If the browser has no Java support such as with a small handheld device the user can maintain the remote host system using the administration forms displayed by the browser Starting the Remote Console opens a new window to display the screen content of the host system The Remote Console acts as if the administrator wer
80. ngs have to be configured accordingly 6 2 Main Window otarting the Remote Console opens an additional window as shown in Figure 33 E Jviewer 10 239 56 12 2 fps Video Keyboard Mouse Options Device Help Macros Ctrl Alt Del Alt Tab ca Administrator Command Prompt C Users Administrator gt Start i m E Administrator Comm Keyboard Video and Mouse redirection Figure 33 Remote Console Main Window It displays the screen content of your remote server The Remote Console will behave as if you were located at the remote server The responsiveness may be slightly delayed depending on the bandwidth and latency of the network between Integrated BMC Web Console and Remote Console Enabling KVM and or media encryption on the Configuration gt Remote Session web page will degrade performance as well Revision 2 2 45 Remote Console KVM Operation Intel Remote Management Module 4 and Integrated BMC Web Console User Guide The Remote Console window always shows the remote screen in its optimal size This means it will adapt its size to the size of the remote screen initially and after the screen resolution of the remote screen has been changed However you can always resize the Remote Console window in your local window as usual 6 3 Remote Console Control Bar The upper part of the Remote Console window contains a control bar Using its elements you can see the status of the Remote Console and inf
81. ngs to take effect the server must be restarted Select the Restart button Intel Deployment Assistant Server Management Settings Finish Restart Server Restart the server for the configuration settings to take effect IP address of Lan Channel 3 10 239 56 110 DHCP Host Name RMM4UG Figure 24 IDA Configure Server Restart Server Revision 2 2 35 Configuring Integrated BMC Web Console and Intel RMM4 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 4 4 Configuring your Server Management NIC using the Intel System Configuration Utility SysConfig This section gives the basic commands needed to configure the RMMA using SysConfig commands This utility is supported in EFI Linux and Windows The commands are the same for all the versions At a minimum you will need to configure the following settings Enable one user Enable user s privilege level Set users and passwords IP source static or DHCP IP Address Subnet mask Default gateway only required if you will be connecting from client outside of subnet Enable text based console redirection serial Over LAN SOL if needed Note The examples in the following sections are using RMM4 Dedicated Server Management NIC LAN channel 3 If you are not using the RMM4 Dedicated Server Management NIC then substitute the appropriate channel number For NIC1 it will be channel 1 For NIC2 it will be channel 2 4 44 1 Configure
82. nnection e Keyboard Mouse Encryption Keyboard and Mouse data are normally encrypted before being sent over the connection but this can be disabled for a small performance increase Revision 2 2 51 Remote Console KVM Operation Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 6 3 5 Remote Console Device Menu Redirect CDROM I Redirect ISO LJ Redirect Floppy U SB Key Li Redirect Floppy USB Key Image Figure 44 Remote Console Device Menu This menu option allows starting stopping remote media redirection The first two options allow you to redirect either a local CDROM DVD drive or else an ISO image on your local client file system as a virtual CDROM device on the remote system The third option allows you to redirect either a local floppy drive or local USB key drive The fourth option allows you to redirect a floppy or USB Key img file on your local client file system as a virtual floppy device on the remote system The virtual devices act just like any other CDROM DVD or floppy on the remote system They can be read written assuming they are not read only and booted The pair of virtual devices only appears on the remote OS or BIOS setup menus when some media redirection is active The virtual devices persist across remote system resets and power up downs They do not disappear from the remote system until the checkboxes are unchecked in the Remote Console window Note The virtual devices
83. nnel Baseboard Mgmt aia MAC Address 00 15 17 FE 32 EC VLAN Enable IPv6 on this Channel SSL Use IPv6 auto configuration stateless ICMPv6 discovery Obtain an IP address automatically use DHCPv6 Use the following IP address IP Address J Remote Session Mouse Mode Keyboard Macros IPv6 prefix length 0 to 128 64 Alerts Alert Email Gateway Node Manager Save Figure 61 Configuration IPv6 Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families WARNING Each network controller should be on a different subnet than all other controllers used for management traffic WARNING When LAN failover is enabled the system administrator should ensure that each network controller connection which can be seen by the BMC has connectivity to the same networks If there is a loss of functionality on the primary network controller channel it will randomly failover to any of the other network controller channels that are connected and seen by the BMC The following table lists the options available in this page Revision 2 2 71 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Table 12 Configuration IPv6 Network Settings Options omm oom 000000 Enable LAN Failover Used to enable LAN Failover LAN Channel drop down box Used to select the Channel that you would like to configure the network settings Li
84. ntegrated BMC Web Console User Guide vi 7 4 Remo CONTONA Derea E E 93 7 4 1 Console Redirection Page iet e a upae UG 93 42 Server Power Control Page scii belii niece 94 7 4 3 Virtual Front Panel Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families cccccccccceecceceeeceeeeeeeeceeeeeseeseeeeeneeeeas 96 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide List of Figures List of Figures Figure 1 Intel RMMA Lite ennetnetnr emeret trenes tese ertet n sns nad 7 Figure 2 Intel Dedicated Server Management NIC sessseseeeeeee nnne 8 Figure 3 Installing Intel RMMA Lite on Intel Server Boards seee 11 Figure 4 Attaching the bracket to Intel Dedicated Server Management NIC module 13 Figure 5 Attaching the cable to Intel Dedicated Server Management NIC module 13 Figure 6 Adding the Intel Dedicated Server Management NIC module in the Intel Server System R1304BTLSFAN R1304BTLSHBN and R2000SC Family ssuusss 14 Figure 7 Adding the Intel Dedicated Server Management NIC module in the Intel Server System R1000BB R1000GZ GL and R2000GZ GL Familes suus 15 Figure 8 Attaching the bracket to Intel Dedicated Server Management NIC module 16 Figure 9 Adding the Intel Dedicated Server Man
85. ode Select Relative Mode to have the calculated relative mouse position displacement sent to the server Use this mode for Linux OS Click Save to use selected mode E at intel Integrated BMC Web Console o vy PF a a a D REFRESH HELP System Information Server Health Configuration Remote Control e LOGOUT Im La Configuration Use these pages to configure various settings such as alerts users or network Mouse Mode Setting Network Select the mouse mode to use from the options below and press the Save button Users Tes Current Mouse Mode is ABSOLUTE LDAP D Set Mode to Absolute Recommended when server OS is Windows SSL 2 Set Mode to Relative Recommended when server OS is Linux Remote Session Save Mouse Mode Keyboard Macros Alerts Alert Email Figure 72 Configuration Mouse Mode Setting Page on S1200BTL platforms On an EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families the Redirection Console handles mouse emulation from local window to remote screen in either of three methods Figure 73 shows the details e Absolute Mode Select to have the absolute position of the local mouse sent to the server Use this mode for Windows and newer Red Hat Linux versions RHEL 6 x 82 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options e Relative Mode Sele
86. on Use these pages to configure various settings such as alerts users or network Node Manager Power Policies 4 A A Integrated BMC Web Console Remote Control Use this page to set Node Manager Power Policies Add Edit Node Manager Policies Policy Number cy Enabled Power Limit Watts Use Policy Suspend Periods Timer 2 Monday _ Tuesday Timer 1 L Monday Tuesday _ Wednesday _ Wednesday Thursday L Thursday Friday Friday _ Saturday Saturday Sunday Start Time 00 00 End Time 00 00 Sunday Start Time _ 00 00 End Time 100 00 c LOGOUT Hard Shutdown Log Event Yes No Timer 3 L Monday Tuesday Wednesday Thursday Friday _ Saturday Sunday _ Start Time 00 00 End Time 00 00 Timer 4 Monday Tuesday _ Wednesday Thursday Friday L Saturday Sunday Start Time 00 00 End Time 00 00 Timer 5 Monday Tuesday Wednesday Thursday Friday Saturday _ Sunday Start Time 00 00 End Time 00 00 Figure 80 Configuration Node Manager Page with Use Poilicy Suspend Period selected 92 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 4 Remote Control
87. one of two I NEN NEUMOS Tm expected events from BIOS on every power on Asserted Rg Microcontroller m 1155 12 02 2010 11 56 49 Unknown Coprocessor reports it has transitioned to a running state Asserted 1154 12 02 2010 11 56 48 Pwr Unit Status Power Unit reports the power units AC is lost Deasserted 1153 12 02 2010 11 56 47 P4 Status Processer reports the processors presence has been detected TT Asserted Ej 1152 12 02 2010 11 56 47 Pwr Unit Status Power Unit reports the power units AC is lost Asserted 1151 42 02 2010 11 56 09 Pwr Unit Status Power Unit mapei ae paer eee ht UMEN ME ar balag DNE ips down Asserted 1150 12 02 2010 11 56 08 Pwr Unit Status Power Unit reports the power unit has suffered a failure Asserted RA reports Timestamp Clock Sync Event is one of two U IRURE expected events from BIOS on every power on Asserted Fa reports Timestamp Clock Sync Eventis one of two T puc HESS expected events from BIOS on every power on Asserted 1147 12 02 2010 11 54 09 Button Button Switch reports the power button has been pressed Asserted 1146 12 02 2010 11 54 09 Pwr Unit Status Power Unit reports the power unit is powered off or being powered c down Deasserted 1145 42 02 2010 11 31 42 SPS FW Health OEM Reserved ee ye Peres ees Pees oe Daing Pee m down Deasserted Asserted 1144 12 02 2010 11 31 41 Unknown reports it has transitioned to a running state Asserted M Clear Event Log
88. ormation Type Part Model Number Serial Number Board Information Manufacturing Date Manufacturer Main Server Chassis 2011 06 12 03 31 Intel Corporation Product Name Serial Number Part Model Number FRU File ID 52600CP QSCP12200240 E99552 301 FRU Ver 0 03 Product Information Manufacturer Intel Corporation Name 52600CP Part Model Number Version Serial Number Asset Tag FRU File ID Figure 49 System Information FRU Information Page 56 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 1 3 System Debug Log Page The System Debug Log page allows administrators to collect system debug information This feature allows a user to export data into a file that is retrievable for the purpose of sending to an Intel engineer or Intel partners for enhanced debugging capability The files are compressed encrypted and password protected The file is not meant to be viewable by the end user but rather to provide additional debugging capability to your system manufacturer or an Intel support engineer 7 1 3 1 System Diagnostic Page on S1200BTL platforms The System Diagnostic page can be used to collect system debug information on S1200BTL systems See Figure 50 for details From the System Diagnostic screen you will be able to run the System Debug Log dump Press the Run button It may tak
89. ow Refreshing readings every 60 seconds Power Statistics Select 3 sensor type category Sensor Readings 40 sensors All Sensors Y me Status ath Reading ow CT wN High NC High Pwr Unit Status All deasserted 0x0000 N A N A N A N A E IPMI Watchdog Alldeasserted RR oxoooo N A N A N A N A FP NMI Diag Int Alldeasserted DEM 00000 NIA NIA NIA NA SMI TimeOut Alldeasserted RM 00000 N A N A N A N A System Event Log Alldeasserted DEE o 0000 N A N A N A N A System Event Alldeasserted RR 00000 N A N A N A N A Button Alldeasserted RR oxcooo N A N A N A N A PCH Therm Trip Alldeasserted DEM oxoo00 NIA NIA NIA NIA 105 114 iBMC Board TEMP Normal LN 38 degrees C oid degrees degrees degrees C C C Front Panel Temp Normal PM 25 degrees C EUBIEES S HBgreps yee m M Refresh Hide Thresholds Set auto refresh in seconds 0 to disable Set P Figure 55 Server Health Sensor Readings Page Thresholds displayed The following table lists the options available in this page Table 9 Server Health Sensor Readings Options EMEN ew MN Sensor Selection pull down box Select the type of sensor readings to display in the list The default is to see all sensors Selected sensors shown with their name status health Sensor Readings list and readings Refresh button Click to refresh the selected sensor readings Click to expand the list showing low and high threshold assignments Shows the critical CT and non critical Show Th
90. rate Alerts and the external network destinations they should be sent to Users Select the events that will trigger alerts Login Temperature Sensor Out of Range L Watchdog Timer LDAP System Restart Voltage Sensor Out of Range SSL Fan Failure Chassis Intrusion Power Supply Failure Memory Error Remote Session BIOS Post Error Code FRB Failure Mouse Mode Node Manager Exception Hard Drive Failure Keyboard Macros o ChekAM e O earal Clear All Alerts LAN Channel to Configure Baseboard Mgmt Alat Emal Alert Destination 1 SNMP Send SNMP Alerts to IP Email Send Email to Alert Destination 2 SNMP Send SNMP Alerts to IP Email Send Email to Save Send Test Alerts Figure 76 Configuration Alerts Page on S1200BTL platforms The following table lists the options allowing you to select the events that alerts should be sent on and selection of where the alerts are to be sent Table 18 Configuration Alerts Options mm C LUE LL Select the events that will trigger alerts Select one or more system events that will trigger an alert Check Clear All buttons Click to select or clear all events LAN Channel to Configure Select either the BMC or RMM4 to configure destination for Revision 2 2 87 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Select either SNMP along with the IP address or email address that Alert Destination 1
91. rated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel RMM4 4 3 Configuring your Server Management NIC using the Intel Deployment Assistant IDA The following section explains how to use IDA to configure the onboard NIC1 and or the RMM4 NIC for use with the Integrated BMC Web Console and the Intel RMM4 The example will show how to configure LAN Channel 3 Intel RMM4 NIC WARNING If you need to configure both LAN Channel 1 and LAN channel 3 RMM4 Dedicated Server Management NIC ensure that they are configured with different subnets Note When the Dedicated Server Management NIC is not installed since the RMMA Lite has no dedicated NIC the LAN Channel 3 is not displayed The user can access RMM4 Lite advance features via LAN channel 1 onboard NIC1 See Figure 17 1 Select which channel to configure Intel Deployment Assistant My Server Advanced di Help T Exit Server Management Settings Finish Communication Options Select server management capabilities to configure LAN Channel 1 onboard NIC1 4 LAN Channel 3 Intel R Remote Management Module 4 cance Figure 16 IDA Configure Server Communication Options Window Revision 2 2 i Configuring Integrated BMC Web Console and Intel RMM4 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Deployment Assistant intel Finish
92. resholds button NC thresholds for the selected sensors Use scroll bar at the bottom to move display left and right Hide Thresholds button d return to original display hiding the threshold Enter the time in seconds to wait between updates of Set auto refresh in seconds 0 to disable selection the Sensor Readings and then press the Set button 64 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 7 2 2 Event Log Page The Event Log page displays the systems server management Event Log Figure 56 shows the details for a S1200BTL system intel Integrated BMC Web Console System Information Server Health Server Health This section shows you data related to the server s health such as sensor readings and the event log Event Log Sensor Readings clicking on a column header Configuration Remote Control Intel Integrated BMC Web Console Options RM i c a LOGOUT REFRESH HELP E Below is a table of the events from the system s event log You can choose a category from the pull down box to filter the events and also sort them by Event Log Select an event log category Power Statistics All Events Event Log 1321 event entries 3 4 A A Seriisvi NYE Statt 7 ASs2clucu z ER reports Timestamp Clock Sync Eventis one of two ii EED MEUM expected events from BIOS on every power on Asserted des reports Timestamp Clock Sync Event is
93. ressing the Show Thresholds button below Event Log Bawer Stanetics Refreshing readings every 60 seconds Select a sensor type category Sensor Readings 40 sensors All Sensors M Pwr Unit Status All deasserted Ox0000 IPMI Watchdog All deasserted EN o0000 FP NMI Diag Int All deasserted END 00000 SMI TimeOut All deasserted a Ox0000 3 System Event Log All deasserted OK Ox0000 System Event All deasserted BO o0000 Button All deasserted EN o0000 PCH Therm Trip All deasserted END 00000 IBMC Board TEMP Normal EN e degrees c Front Panel Temp Normal OK 25 degrees C Board Inlet TEMP Normal OK 25 degrees C Sys Fan 3 Normal EE 206 nrw Refresh Set auto refresh in seconds 0 to disable Set Figure 54 Server Health Sensor Readings Page Thresholds not displayed Revision 2 2 63 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide intel Integrated BMC Web Console mew r 2 wee Q HELP System Information Server Health Configuration Remote Control c3 LOGOUT REFRESH Server Health This section shows you data related to the server s health such as sensor readings and the event lag Sensor Readings Sensor Readings This page displays system sensor information including readings and status You can toggle viewing the thresholds for the Event Log sensors by pressing the Show Thresholds button bel
94. s 3 Carefully pickup RMM4 Lite module keep the direction of key pin of the RMM4 Lite connector and insert the RMM4 Lite into that connector Note For more details see your specific Inte Server Systems Technical Product Specification and Intef Server Systems Service Guide Table 2 Intel Server Boards RMMA Lite Connector Locations Intel Server RMM4 Lite Connector Board Reference Designator AF003760 Figure 3 Installing Intel RMMA Lite on Intel Server Boards Revision 2 2 11 Hardware Installations and Initial Configuration Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 3 3 2 Installation of the Intel Dedicated Server Management NIC on an Intel Rack Server System Most Intel Rack Server Systems allow the Intel Dedicated Server Management NIC module to be mounted to the chassis Table 3 lists all of the Intel Rack Server Systems that support a chassis mounted Intel Dedicated Server Management NIC module The following are steps that should be used when installing the Dedicated Server Management NIC module on those server systems 1 Ensure that AC power has been removed from the system and that you have waited at least 30 seconds after removing power Note For the next steps see your specific Inte Server Systems Technical Product Specification and Intel Server Systems Service Guide for more details If appropriate Table 4 will list the figure showing the installation for that specifi
95. s such as alerts users or network VLAN Settings IPv4 Network Check the box below to enable a VLAN private network on this channel and configure it Press the Save button to save your IPv6 Network changes Users LAN Channel Baseboard Mgmt v Login Enable VLAN LDAP VLAN ID 1 4094 VLAN Remote Session Si Mouse Mode Keyboard Macros Alerts Alert Email Node Manager Figure 68 Configuration VLAN Settings on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families The following table lists the options available in this page Table 14 Configuration VLAN Settings Options LAN Channel drop down box Lists the LAN Channel s available for VLAN The LAN channel describe the physical NIC connection on the server Intel R RMM BMC LAN Channel 3 is the add in RMM4 NIC Baseboard Mgmt BMC LAN Channel 1 is the onboard shared NIC configured for management and shared with the operating system Baseboard Mgmt 2 BMC LAN Channel 2 is the second onboard shared NIC configured for management and shared with the operating system Enable VLAN Used to enable VLAN for the LAN channel selected in the drop down box VLAN ID 1 4094 Used to set the VLAN ID 78 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options a NN VLAN Priority 0 7 Used to set the VLAN Priority Save button Click to sa
96. s is also available on the resource disc that is shipped with the server board e SYSCFG htip downloadcenter intel com default aspx gt relevant server platforms page Two steps are necessary before Server Management BMC LAN or the Intel RMM4 can be used 1 One or both LAN channels must be configured as either DHCP or static addresses 2 Atleast one user must be enabled to use the LAN channel s ee Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 4 1 10 Configuring Integrated BMC Web Console and Intel RMM4 Configuring your Server Management NIC using BIOS setup on S1200BTL During POST press F2 to go to BIOS setup Navigate to the Server Management tab and then scroll down to BMC LAN Configuration Press lt Enter gt If configuring your Server Management BMC LAN scroll to IP source IP source and then select either Static or Dynamic If configuring your Intel RMMA then scroll down to Intel R RMM4 LAN configuration IP source and then select either Static or Dynamic If Static is selected configure the IP address Subnet mask and Gateway IP as required Scroll down to User ID Select the User that you want to use Scroll down to User status Select Enabled Scroll down to User name Change the name as needed Note that you cannot change anonymous or root Scroll down to User password Change the password Note that you will need to enter the password t
97. s shown in Figure 64 a A R l di DUE f J i 3 f 77 intel Integrated BMC Web Console System Information Server Health Configuration Remote Control e LOGOUT REFRESH 3 HELP E ECT Configuration B L e Use these pages to configure various settings such as alerts users or network ys Modify User Network Enter the new information for the user below and press Modify Press Cancel to return to the user list Users User Name root Login Change Password LDAP x SSL Password Remote Session Confirm Password Mouse Mode Enable Access Keyboard Macros Network Privileges Administrator Alerts Alert Email Figure 64 Configuration Users Modify User Page 74 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 3 4 Login Security Settings Page Users can be locked out if they supply incorrect passwords too many times in a row This is a security feature to prevent brute force hacking attacks Only that user is locked out other users can still login The number of failed attempts before being locked out is configurable as is the length of time the lockout lasts To turn the feature off set the lockout time to zero Three default failures will lockout a user for one minute Press the Save button to save any changes intel Integrated BMC Web Console System Information Server Health Configurat
98. second pause in the key sequence Key names are either a printable character such as a 5 and so on or else one of the non printable keys in the table below Names in parentheses are aliases for the same key Numeric keypad keys are prefixed with NP A plain indicates a pause Use for the actual key The V key must also be escaped as NW Note The key sequences are sent to the target as scan codes that get interpreted by the target OS so they will be affected by modifiers such as Numlock as well as the target OS keyboard language setting Table 17 Macro Non printable Key Names Us fron GmerWew o Pease Swine sux fme 86 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 3 11 Alerts Page Use this page to configure which system events an alert should be sent for and the destination for the alerts Up to two destinations can be selected for each LAN channel Figure 76 shows the details for a S1200BTL system h LE intel Integrated BMC Web Console y 4 omm E gi y J n System Information Server Health Configuration Remote Control e LOGOUT REFRESH HELP Configuration Use these pages to configure various settings such as alerts users or network Alerts Network Configure which system events gene
99. send a platform event Log Event check box message to the BMC when a policy is exceeded If enabled you may configure policy suspend periods Each policy may have up to five suspend periods see Figure 80 Use Policy Suspend Periods Suspend periods are repeatable by day of week Start and stop times are designated in 24 hour format in increments of 6 minutes To specify a suspended period crossing midnight two suspend periods must be used For all policies set through this page the following default values will be applied e Domain Platform Power for the entire platform e Trigger None Always monitor after end of POST e Aggressive CPU Power Correction AUTO Use of T states and memory throttling controlled by policy exception actions e Trigger Limit None e Reporting Period 10 seconds This is a rolling average for reporting only It will not affect the average power monitored by the node manager e Correction Timeout 22 555 seconds Maximum time for the NM to correct power before taking an exception action i e shutdown or alert Revision 2 2 91 Intel Integrated BMC Web Console Options intel System Information IPv4 Network IPv6 Network Users Login Server Health LDAP VLAN SSL Remote Session Mouse Mode Keyboard Macros Alerts Alert Email Node Manager Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Configuration Configurati
100. server Microsoft Windows Server 2008 SP2 IA32 and EM64T Microsoft Windows Server 2008 R2 Red Hat Enterprise Linux 6 for IA32 and EM64T SUSE Enterprise Linux 11 SP1 for A382 and EM64T 2 3 2 Client System The following client Internet browsers have been tested Microsoft Internet Explorer 7 0 Microsoft Internet Explorer 8 0 Microsoft Internet Explorer 9 0 Mozilla Firefox 3 0 Mozilla Firefox 3 5 Mozilla Firefox 3 6 Revision 2 2 9 Hardware Installations and Initial Configuration Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 3 Hardware Installations and Initial Configuration This section guides you on the hardware installations and initial configuration 3 1 Before You Begin Please read the Safety Information provided at the beginning of this manual before working with your server product 3 2 Tools and Supplies Needed Following are the tools and supplies needed e Phillips cross head screwdriver 1 bit and 2 bit e Needle nosed pliers e Antistatic wrist strap and conductive foam pad recommended 3 3 Installation The Intel RMM4 has three different packages e RMM4 Lite edition AXXRMM4Lite which contains the following components o Intel Remote Management Module 4 Lite module e RMM4 full edition AXXRMM4 which contains the following components o Intel Remote Management Module 4 Lite module o Intel Dedicated Server Management Network Interface Card NIC
101. ssnanedaetceuadssteneentaaiainuasmeus Sa T EESE EEEa aO tuu Deomm suman oe a ocu ud 19 Configuring Integrated BMC Web Console and Intel RMMA eene 22 4 1 Configuring your Server Management NIC using BIOS setup on S1200BTL 23 4 2 Configuring your Server Management NIC using BIOS setup on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 25 4 3 Configuring your Server Management NIC using the Intel Deployment Assistant IDA 27 4 4 Configuring your Server Management NIC using the Intel System Configuration Wee ieri Me E 36 4 4 1 CODIIgure USO scott cedat one ect tud been t ee ae en eee eee t RU 36 442 Gonfg ririg IPaddresS sciunt t ue outset abso aee enisi ata toties pee tds 36 4 4 3 Configuring Serial Over LAN eeeesseseseeeeeenennnennnn nennen nnns 36 Getting Started with Intel RMMA Operation eee nnne 37 5 1 DEIOle YOU BEGIM e c EP 37 5 1 1 SVN OW SOUS NRI 37 5 2 LOGON MIR REI T 38 5 3 weder rere 39 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Table of Contents 5 4 OMNE eee 41 5 5 LOGOM R6 UPON 41 6 Remote Console KVM Operation ccccccsseeecenseeceeseescenseeeeasseeeenseecoaseeecaneeseanseesonss 43 6 1 Launching the Redirection Console
102. stalled the advanced management features are available through both the optional Intel Dedicated Server Management NIC if installed and all of the onboard Integrated BMC shared NIC ports If the optional Intel Dedicated Server Management NIC is installed the NIC is dedicated to the Intel RMM4 advanced management features traffic along with all other standard server management traffic The host system is unaware of this NIC If the optional Intel Dedicated Server Management NIC is not used then the traffic can go through any of the onboard Integrated BMC shared NIC ports and will share network bandwidth with the host system Figure 1 Intel RMM4 Lite Revision 2 2 7 Intel Remote Management Module 4 Overview Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Figure 2 Intel Dedicated Server Management NIC 2 2 Intel RMM4 Features The Intel RMM4 add on offers convenient remote KVM access and control via LAN or Internet It captures digitizes and compresses video and transmits it with keyboard and mouse signals to and from a remote computer Remote access and control software runs in the Integrated Baseboard Management Controller utilizing expanded capabilities enabled by the Intel RMM4 hardware Key features of the Intel RMM4 add on card are e KVM redirection via either the RMM4 NIC or the baseboard NIC used for management traffic up to two simultaneous KVM sessions e Media re
103. sts the LAN Channel s available for server management The LAN channels describe the physical NIC connection on the server Intel RMM BMC LAN Channel 3 is the add in RMM4 NIC Baseboard Mgmt BMC LAN Channel 1 is the onboard shared NIC configured for management and shared with the operating system Baseboard Mgmt 2 BMC LAN Channel 2 is the second onboard shared NIC configured for management and shared with the operating system MAC Address The MAC address of the device read only Enable IPv6 on this channel Used to enable IPv6 on the channel selected in the LAN channel drop down box selection box IP address radio buttons Select one of the three options for configuring the IP address Use IPv6 auto configuration stateless ICMPv6 discovery uses ICMPv6 to obtain the IP address Obtain an IP address automatically use DHCPv6 Uses DHCPv6 to obtain the IP address Use the following IP address Manually configure the IP address IP Address If configuring a static IP enter the requested address and gateway in the given fields Gateway IP Address and Gateway are 128 bit fields made of 8 hexadecimal numbers separated by colons as in XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXxx ranges from O to FFFF First xxxx must not be 0 One or more consecutive groups of zero value may be replaced with a single empty group using two consecutive colons IPv6 prefix length 0 to Selects the routing prefix length
104. t Destinatian zl Alert Email SNMP Send SNMP Alerts ta IP 0 0 0 0 Made Manager Email Send Email to Alert Destination 2 SNMP Send SNMP Alerts to IP 0 0 0 0 O Email Send Email to Save Send Test Alerts Figure 77 Configuration Alerts Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 88 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Integrated BMC Web Console Options 7 3 12 Alert Email Page Use this page to configure the parameter for Alert Emails intel Integrated BMC Web Console Ox j a L LE m 3 System Information Server Health Configuration Remote Control e LOGOUT REFRESH 0 HELP Configuration Use these pages to configure various settings such as alerts users or network Alert Email Settings Network Configure how Alerts are sent by email to an external SMTP Mailserver Each LAN Channel has a seperate configuration Users LAN Channel Baseboard Mgmt Login SMTP Server IP 0 0 0 0 LDAP SSL Sender Address Remote Session Local Hostname Mouse Mode Save Keyboard Macros Alerts Alert Email Figure 78 Configuration Alert Email Page Table 19 Configuration Alert Email Options mm 0 UE LAN Channel Select either the BMC or RMM4 to configure destination for The IP address of the remote SMTP Mail server that Alert email should be sent to SMTP Server IP
105. ta e Compatibility documentation for memory hardware add in cards chassis support matrix and operating systems e Server and chassis accessory parts list for ordering upgrades or spare parts e Asearchable knowledgebase to search for product information throughout the support site 2 If you are still unable to obtain a solution for your issue you can contact Intel customer support at the following website http www intel com support feedback htm 1 5 Warranty Information To obtain warranty information visit the following Intel web site http www intel com support motherboards server sb CS 010807 htm 6 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Intel Remote Management Module 4 Overview 2 Intel Remote Management Module 4 Overview This section gives you an overview of the Intel RMM4 and highlights significant benefits of its features 2 1 Intel RMM4 Lite and Intel Dedicated Server Management NIC RMM4 is comprised of up to two boards Intel RMMA Lite and the optional Intel Dedicated Server Management NIC DMN The Intel RMMA Lite is a small board that unlocks advanced management features on the RGMII interface when installed on Intel server boards It provides an increased level of manageability over the basic server management available to the server board It works as an integrated solution on your server system Once the Intel RMMA Lite has been in
106. ted BMC Web Console User Guide Intel Integrated BMC Web Console Options intel Integrated BMC Web Console a A ft Sal OD OUT REFRESH System Information Server Health Configuration Remote Control c LOG 0 HELP P 5 a gt Configuration Use these pages to configure various settings such as alerts users or network IPv4 Network Settings IPv4 Network You can view and modify the IPv4 network settings on this page Select whether to obtain an IP address automatically or IPv6 Network manually configure one Users Enable LAN Failover Login LDAP VLAN SSL Remote Session LAN Channel Baseboard Mgmt MAC Address 00 1E 67 0D D4 A7 O Obtain an IP address automatically use DHCP 9 Use the following IP address Disable LAN Channel Mouse Mode IP Address 172 24 243 43 Keyboard Macros Subnet Mask 255 255 255 0 Alerts Default Gateway 172 24 243 251 Alert Email Node Manager Primary DNS Server Secondary DNS Server Figure 60 Configuration IPv4 Network Settings Page on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families WARNING Each network controller should be on a different subnet than all other controllers used for management traffic WARNING When LAN failover is enabled the system administrator should ensure that each network controller connection which can be seen by the BMC has connectivity to the same networ
107. tem memory map The system memory map is provided by BIOS on the current boot This includes the EFI memory map and the Legacy E820 memory map depending on the current boot Power supplies debug capability e Capture of power supply black box data and power supply asset information Power supply vendors are adding the capability to store debug data within the power supply itself The platform debug feature provides a means to capture this data for each installed power supply The data can be analyzed by Intel for failure analysis and possibly provided to the power supply vendor as well The BMC gets this data from the power supplies via PMBus manufacturer specific commands e Storage of system identification in power supply The BMC copies board and system serial numbers and part numbers into the power supply whenever a new power supply is installed in the system or when the system is first powered on This information is included as part of the power supply black box data for each installed power supply Accessibility via IPMI interfaces The platform debug file can be accessed via an external IPMI interface KCS or LAN POST code sequence for the two most recent boots This is a best effort data collection by the BMC as the BMC real time response cannot guarantee that all POST codes are captured Support for multiple debug files The platform debug feature provides the ability to save data to 2 separate files that are encrypted with
108. tings 4 Enable LAN Channel 3 IP Address Subnet Mask Gateway Enable Serial Over LAN l Configure Alert Figure 19 IDA Configure Server Configure LAN Channel 3 Intel RMM4 DMN Static IP Address window 30 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel RMM4 4 Optional Setup the users by selecting the User Name and then clicking on Edit The Edit User Data window opens Intel Deployment Assistant intel a RP PEE ROEE TOT SORTA E RA SR PR Nr S NETTEN RIEN OT TOT TOT TTT OTT Server Management Settings Jd Finish Set Up Users Set up user accounts for this server User Name Status Password User Privileges Anonymous User Disabled tote ADMIN testl Enabled Yootolooorek Admin test2 Disabled Noo ADMIN test3 Disabled xxr ADMIN k cancel Figure 20 IDA Configure Server Set Up Users window Notes e You cannot login to the Integrated BMC Web Console RMM4 Remote Console as Anonymous User You must modify existing users e Enable and edit username passwords set privilege for the users as shown below Revision 2 2 31 Configuring Integrated BMC Web Console and Intel RMM4 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide 5 Edit the User information and click OK to apply configuration Intel Deployment Assistant Server Management Settings Finish Set Up Users
109. tion implementing the Remote Console Both Microsoft Internet Explorer and Mozilla Firefox browsers are supported Notes e Java Run Time Environment JRE Version 6 Update 22 or higher must be installed on the client prior to the launch of a JNLP file e The client browser must allow pop up windows from the Integrated BMC Web Console IP address E JViewer 10 239 56 101 2 fps con fmt Video Keyboard Mouse Options Device Help Macros Ctrl Alt Del Alt Tab Current ruming mode 1 1 2 HardDisk Alias Acpi PNPOA03 0 Pci CAF 12 Sata 2 FFFF 0 HD Part1 SigDF FDF7F BlockDevice Alias Acpi PNPOAOS 0 Pci 1F 12 Sata 2 FFFF 0 Press ESC in 1 seconds to skip any other key to continue Keyboard Video and Mouse redirection Figure 32 Remote Console The Remote Console window is a Java Applet that establishes TCP connections to the Integrated BMC Web Console The protocol that is used to run these connections is a unique KVM protocol and not HTTP or HTTPS This protocol uses ports 7578 for KVM 5120 for 44 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Remote Console KVM Operation CDROM media redirection and 5123 for Floppy USB media redirection Your local network environment must permit these connections to be made that is your firewall and in case you have a private internal network your NAT Network Address Translation setti
110. troduction INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif ricos conectados al sistema 2 Apague el sistema presionando el interruptor encendido apagado 3 Desconecte todos los cables de alimentaci n CA del sistema o de las tomas de corriente alterna 4 Identifique y desconecte todos los cables enchufados a los conectores E S o a los puertos situados en la parte posterior del sistema 5 Cuando manipule los componentes es importante protegerse contra la descarga electrost tica ESD Puede hacerlo si utiliza una munhequera antiest tica sujetada a la toma de tierra del chasis o a cualquier tipo de superficie de metal sin pintar 6 No ponga en marcha el sistema si se han extra do las tapas del chasis Si el sistema ha estado en funcionamiento el microprocesador y el disipador de calor pueden estar a n calientes Tambi n conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes Por ello se recomienda precauci n y el uso de guantes protectores AVVERTENZA Italiano PASSI DI SICUREZZA Qualora si rimuovano le coperture del telaio per accedere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore del sistema 3
111. u can view and modify keyboard macros on this page Button Name is optional Use Help to see the supported key names Users Key Sequence Button Name Login 1 Ctrl Alt Del Ctrl Alt Del LDAP SSL 2 Alt Tab Alt Tab Remote Session 3 Mouse Mode 4 Keyboard Macros 5 Alerts Alert Email 6 7 8 9 10 Save Figure 75 Configuring Keyboard Macros Page This makes it convenient to quickly do oft repeated typing as well as execute key combos that aren t possible directly from the local client keyboard Alt and Win key combos such as Ctrl Alt Del get interpreted by the local client OS and aren t passed through to the remote target OS However a macro can be set up to take care of this Each button can optionally be given a short mnemonic name If this field is blank the key sequence itself will also be used as the button label You must save changes before they take effect If a Remote Console session is open at that time you will not see the changes until that session is closed and a new session is opened 7 3 10 1 Key Sequences A key sequence is a set of one or more key names separated by a or Revision 2 2 85 Intel Integrated BMC Web Console Options Intel Remote Management Module 4 and Integrated BMC Web Console User Guide A indicates keep the previous keys pressed while holding down the next key whereas a indicates release all previous keys first before pressing the next key A inserts a one
112. uthorized for use in any medical lifesaving or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur Intel may make changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for cooling Intel s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non operating limits Intel is a trademark of Intel Corporation in the U S and other countries Microsoft Windows and Windows Server are trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries Other names and brands may be claimed as the property of others Copyright Intel Corporation 2012 All rights reserved Revision 2 2 iii Table of Contents Intel Remote Management
113. v6 network a If configuring your Server Management BMC LAN Scroll to Baseboard LAN IPv6 configuration IP source and then select Enabled 1 Scroll to IPV6 source and select either Static or Dynamic b If configuring your Intel RMMA then scroll down to Intel R RMM4 IPV6 LAN configuration IP source And then select either Static or Dynamic c If Static was selected configure the IPV6 address Gateway IPV6 and IPV6 Prefix Length as needed 5 Scroll down to User ID Select the User that you want to use 6 Scroll down to User status Select Enabled 7 Scroll down to User name Change the name as needed Note that you cannot change anonymous or root 8 Scroll down to User password Change the password Note that you need to enter the password twice 9 When you are finished configuring the LAN addresses and User information for the server press the F10 key and select save and exit your server will reboot with the new LAN settings Revision 2 2 25 Configuring Integrated BMC Web Console and Intel RMM4 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Aptio Setup Utility Copyright 0 2010 2011 American Megatrends Inc IP source Stat ic IP address 72 24 243 47 Figure 15 Server Management BMC LAN Configuration on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families 26 Revision 2 2 Intel Remote Management Module 4 and Integ
114. ve the current settings 7 3 7 SSL Upload Page Use this page to upload an SSL certificate and privacy key which allows the device to be accessed in secured mode intel Integrated BMC Web Console v REFRESH f T 4 HELP E System Information Server Health Configuration Remote Control e LOGOUT 5 a Configuration DF N Use these pages to configure various settings such as alerts users or network SSL Upload Network The dates for the default certificate and privacy key are shown below To upload a new SSL certificate use the Browse button to navigate to the certificate and press the Upload button Users Login Default Certificate Wednesday December 31 1969 4 00 00 PM LDAP Default Privacy Key Wednesday December 31 1969 4 00 00 PM SSL s New SSL Certificate Remote Session Mouse Mode Upload Keyboard Macros Alerts Alert Email Figure 69 Configuration SSL Upload Page First upload the SSL certificate and then the device will prompt to upload privacy key If either of the files is invalid the device will notify The device will give notification on Successful upload On successful upload device will prompt to reboot the device If you want to reboot click Ok or click Cancel to cancel the reboot operation First upload the SSL certificate and then the device will prompt to upload the privacy key Click the Upload button On successful upload a notification appears 7 3 8
115. ver The tab automatically opens the System Information page System Information System Information FRU Information CPU Information only on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families DIMM Information Click this tab for access to the sensors and event log The tab automatically opens the Sensor Readings page Server Health e Sensor Readings e Event Log e Power Statistics Revision 2 2 39 Getting Started with Intel RMM4 Operation Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Click this tab to configure various settings for the server The tab automatically opens the Network configuration page Network IPv4 Network IPv6 Network only on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families Users Login LDAP Configuration VLAN only on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families SSL Remote Session Mouse Mode Keyboard Macros Alerts Alert Email Node Manager only on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families Click this tab for access to the remote console and to control the power state of the server l _Rremote Control Console Redirection Server Power Control Virtual Front Panel only on EPSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families
116. wice When you are finished configuring the LAN addresses and User information for the server press the F10 key and select save and exit your server will reboot with the new LAN settings Revision 2 2 23 Configuring Integrated BMC Web Console and Intel RMM4 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Aptio Setup Utility Copyright 0 2010 American Megatrends Inc Br IP source Static i 7 JCE mu Cd 63 Figure 14 Server Management BMC LAN Configuration on S1200BTL e4 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel RMM4 4 2 Configuring your Server Management NIC using BIOS setup on EPSD Platforms Based on Intel Xeon Processor 5 4600 2600 2400 1600 1400 Product Families 1 During POST press F2 to go to BIOS setup 2 Navigate to the Server Management tab and then scroll down to BMC LAN Configuration Press Enter 3 lf you will be using a IPv4 network a If configuring your Server Management BMC LAN Scroll to Baseboard LAN configuration IP source and then select either Static or Dynamic b If configuring your Intel RMMA then scroll down to Intel R RMM4 IPV4 LAN configuration IP source and then select either Static or Dynamic c If Static was selected configure the IP address Subnet mask and Gateway IP as needed 4 f you will be using a IP
117. ys handle boards carefully They can be extremely sensitive to ESD Hold boards only by their edges After removing a board from its protective wrapper or from the server place the board component side up on a grounded static free surface Use a conductive foam pad if available but not the board wrapper Do not slide board over any surface Installing or removing jumpers A jumper is a small plastic encased conductor that slips over two jumper pins Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers If your jumpers do not have such a tab take care when using needle nosed pliers to remove or install a jumper grip the narrow sides of the jumper with the pliers never the wide sides Gripping the wide sides can damage the contacts inside the jumper causing intermittent problems with the function controlled by that jumper Take care to grip with but not squeeze the pliers or other tools you use to remove a jumper or you may bend or break the pins on the board 2 Revision 2 2 Intel Remote Management Module 4 and Integrated BMC Web Console User Guide Introduction Safety Cautions Read all caution and safety statements in this document before performing any of the instructions See also Inte Server Boards and Server Chassis Safety Information at http www intel com support motherboards server sb cs 010770 htm SAFETY STEPS Whenever you remove the chassis covers to

Download Pdf Manuals

image

Related Search

Related Contents

HEA and PPA HyperCel™ Mixed-Mode    CCTVシステム 一 歩先行 く 安 心 な 監視 シ ス テ ム ラ イ ン ナ ッ プ    

Copyright © All rights reserved.
Failed to retrieve file