1.  In addition to the temperature setting the user can select the preferred heating mode  The two  available heating modes are        1  Demand Heating  displayed as Ht d   This is the default setting in which the pump  amp  heater  will come on automatically whenever the temperature drops slightly below the set point     2 Filtration Only Heating  displayed as Ht F   In this mode the pump  amp  heater will come on  automatically no more than once per hour to filter  amp  heat the water  This mode is provided as  an option for those who prefer to limit the natural cycling of the system     To select the heating mode first press the Pump  amp  Down buttons simultaneously to display the  current heating mode  then press  amp  hold the Up or Down buttons to change modes           Press Up or Down       Press both buttons buttons to toggle  simultaneously between heating an Om ee    SRA POWER SOO modes SRA POWER SOO       SPA WATER TREATMENT    Recommended Chemical Values    Chlorine    1 5   3 0 PPM  Parts Per Million   isl PE EEPE E EE TT 74 7 6  Total alkalinity                  100   120 PPM    It is important to maintain your spa water chemistry to the above values to ensure a  healthy experience both for you as bathers  amp  for your spa pool equipment     PH   This is a measure of how acid or alkaline the spa water is  below 7 0 is acid  above 7 0 is  alkaline   Low pH will cause corrosion of any metalwork in the water  element  thermostat  pockets   High pH will cause scale
2.  formation  amp  cloudy water     Total Alkalinity   This is a measure of how resistant your spa water is to change of pH  A low TA  0   80 ppm   will allow the pH to fluctuate rapidly normally to the acid end  amp  will make it very hard to correct  the pH back to the ideal range     Chlorine  Levels of sanitiser are important to prevent the build up of bacteria  amp  algae in the pool water   Chlorine is not the only sanitiser available to do this  Other sanitisers are Bromine  amp  Ozone     Damage to the element  thermostat pockets  amp  associated metalwork due to the poor  maintenance of water chemistry is not covered by warranty     SELF DIAGNOSTIC ERROR CODES   The Spa Power 500A Mk2 controller has extensive self diagnostic capabilities  In the event  of a problem it will indicate an error number according to the nature of the problem  The  error numbers  amp  their meanings are listed below  Note  When in an error state the alarm  can be muted by pushing the AIR AUX button     Error 1  H20    Prime Failed   This is not necessarily a problem with the SP500A Mkz2 itself  but indicates that no water  is being detected in the heaters housing  Prime failed is a special case in that it can be  recovered from by pushing a button  A push of the pump button will run the pump for 10  seconds to try to get water to the heater  If successful normal operation will resume  If  unsuccessful  Error 1  H20  will be indicated on the display again     With any Error 3   5  7   8  spa o
3. ER 500A Mk2 control system  This  controller makes use of the latest technology  including innovative optical  amp  digital sensor  designs  The user friendly touchpad  amp  reliable components provide you with the best    value controller in its class     TEMPERATURE CONTROL   The SpaPOWER 500A Mk2 automatically controls the pump  amp  heater to filter the water  amp   maintain it at the desired temperature as set by the user  see below   The user can leave the  system to look after the spa  amp  know it will be at the correct temperature whenever he or she  wants to use it     Adjusting Set Temperature   The SpaPOWER 500A Mkz2 gives the user direct control of the pool temperature from the  poolside control panel  Holding down the Up or Down button will adjust the temperature set  point as shown on the digital readout  There is a slight delay before the buttons operate to  reduce the risk of accidental adjustment  The pool temperature will be maintained very close  to the set temperature     A  UP Increase the set temperature by 0 5  C per beep  Max   41 5  C     v  DOWN Decrease the set temperature by 0 5  C per beep  Min   10  C   Default Display   Temperature Set Point 3710    Sensed Temperature   The sensed temperature  in the heater  can be Press both buttons  checked if necessary by pressing the Up  amp  Down simultaneously  buttons simultaneously  The display flashes while   showing the sensed temperature           HEATER    SRA POWER SOO       Heating Mode Selection 
4. SPIP OMER       SP500 Spa Pool    Controllers User Guide    A  A    WARNING  Before using ensure that the spa pool has been connected to a suitable weather protected  outlet socket  equipped with a double pole isolating switch  which is of the correct rating and complies with the  local wiring regulations     When installing  refer to your local wiring code  In particular refer to ECP2  amp  ECP25  AS NZ  and EN60364   4 1  amp  EN60364 7 1  EU   The system must be installed in such a way that live parts are not accessible by  a person in the pool  If a supply cord is not fitted the system must be permanently connected to fixed wiring  through a 30mA or less RCD     It is recommended that the steel reinforcing in any concrete base on which the pool is sitting be equipotential  bonded to the earth conductor in the supply to the spa  This is to protect against the possibility of low voltage  shocks caused by differential earth voltages  Refer to AS NZS3000 2000 Sections 5 8  amp  7 2 or EN 60364     WARNING  This appliance is not intended for use by young children or infirm persons without supervision   Young children should be supervised to ensure they do not play with the appliance     WARNING  This product must be covered by an enclosure to prevent water ingress   If the supply cord is damaged  it must be replaced by Davey  a Davey service agent  or a  similarly qualified person in order to avoid a hazard        CONGRATULATIONS   Congratulations on choosing the latest SoaPOW
5. e call service for assistance     Error 7   Stuck Relay  This error indicates a problem with the heater control circuitry inside the unit  Contact your  spa pool supplier     Error 8   No Temperature Data   This error indicates a problem with the digital temperature sensor in the heater or pool wall   or that both the in heater  amp  in pool sensors are connected  Check that only one sensor is  connected  amp  that it has not become disconnected or damaged  Try to reset the spa  If there is  still a problem then contact your spa pool supplier     PUMP OPERATION   The default state is Auto Mode in which the pump  amp  heater are controlled automatically to  filter the water  amp  maintain the desired water temperature  The Pump Button allows the user  to control the water pump manually as desired when using the pool       Pump    Push 1   Pump ON  Heater automatic   Push 2   Pump OFF  Heater OFF   Push 3   Auto Mode  Pump  amp  Heater automatic     Note  If the user does not set the system back into Auto mode  the system reverts to  Auto Mode by itself  90 minutes after the last push of the Pump Button     Indicator Lights    AUTO Flashing   No Water  HEATER Flashing   Error                POWER Pump Button          Auto Light  The YELLOW or BLUE Auto indicator light will appear on the touch pad whenever the  system is in full automatic control mode  In this mode the system automatically activates  the pump  amp  heater to filter the water  amp  maintain the set water temperat
6. irect or special loss  damage  or injury of any kind whatsoever arising directly or indirectly from Davey products  This limitation  does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to  your Davey product under the Australian or New Zealand legislation and does not affect any rights or  remedies that may be available to you under the Australian or New Zealand Consumer Legislation     In Australia  you are entitled to a replacement or refund for a major failure and for compensation for  any other reasonably foreseeable loss or damage  You are also entitled to have the goods repaired  or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major  failure     Should your Davey product require repair or service after the guarantee period  contact your nearest  Davey Dealer or phone the Davey Customer Service Centre on the number listed below     For a complete list of Davey Dealers visit our website  davey com au  or call        et Rainbow Pool Products    Re PO Box 2388  Mansfield Qld 4122  ey Telephone STD 61 7 3849 5385  2 POOL PRODUCTS Facsimile STD 61 7 3849 5384         Email  info rainbowpoolproducts com au         Quality Pool  amp  Spa Produts Web  www rainbowpoolproducts com au         Installation and operating instructions are included with the product when purchased new   They may also be found on our website     
7. peration will stop  amp  not continue until the controller  is reset  The controller can only be reset by pushing the UP JDOWN  amp  PUMP buttons  simultaneously     The controller will remain in an error condition   even when reset at mains power  controller   will only continue normal operation after   the UP  DOWN  amp  PUMP buttons are pushed seca   simultaneously  see below   Up Button  Down Button    ump Button       Error 3   Stuck Button   This error indicates that one of the buttons in the touchpad is stuck or has been held down  for more than one minute  This may be caused by the pool cover pressing on the touchpad  or by water getting into the touchpad or by damage to the touchpad or its cable  Try to  reset the spa  If there is still a problem then contact your spa pool supplier     Error 4   No Water Sensor   This error indicates a problem with the optical water sensor in the heater  The problem may  be caused by the sensor being disconnected or by damage to the sensor  Try to reset the  spa  If there is still a problem then contact your spa pool supplier     Error 5   Overtemperature   This error indicates that the digital temperature sensor in the heater or pool has detected   a temperature of 45  C or more  This may not be a problem with the SP500A Mkz2  it may  be caused by excessive pump use in hot weather  or pump failure  Turn off the spa  amp  allow  time for the water to cool  If there is still a problem contact your spa pool supplier     Error 6   Pleas
8. s with your Davey product  we suggest in the first instance that  you contact the Davey Dealer from which you purchased the Davey product  Alternatively you can  phone our Customer Service line on 1300 367 866 in Australia  or 0800 654 333 in New Zealand  or  send a written letter to Davey at the address listed below  On receipt of your claim  Davey will seek to  resolve your difficulties or  if the product is faulty or defective  advise you on how to have your Davey  product repaired  obtain a replacement or a refund     Your Davey Two Year Guarantee naturally does not cover normal wear or tear  replacement of product  consumables  i e  mechanical seals  bearings or capacitors   loss or damage resulting from misuse   or negligent handling  improper use for which the product was not designed or advertised  failure to  properly follow the provided installation and operating instructions  failure to carry out maintenance   corrosive or abrasive water or other liquid  lightning or high voltage spikes  or unauthorized persons  attempting repairs  Where applicable  your Davey product must only be connected to the voltage  shown on the nameplate     Your Davey Two Year Guarantee does not cover freight or any other costs incurred in making a claim   Please retain your receipt as proof of purchase  you MUST provide evidence of the date of original  purchase when claiming under the Davey Two Year Guarantee     Davey shall not be liable for any loss of profits or any consequential  ind
9. ur    4 hours per day   Holding down the Up Button   A  or Down Button v  will adjust the filtration time setting between 0  amp  15 minutes  per hour    0 to 6 hrs per day      Clean Up Cycle   If desired a clean up cycle can be initiated to filter the water after the spa pool has been  used  This is done by simply pushing the Pump Button   to leave Auto Mode  amp  switch  on the pump  This will circulate the water through the filter for 90 minutes  After 90 minutes  the system will return to Auto Mode  amp  maintain the temperature ready for the next time the    spa pool is used     AUXILIARY AIR BUTTON  The Air button controls an auxiliary air blower  or water pump   It is used to turn the blower  on  amp  off  Two pushes of the air button cycles the blower as follows       Air Blower or Auxiliary Pump    Push 1   Blower ON  Push 2   Blower OFF       POWER    Note  If left on  this accessory will automatically switch off after 20 minutes  If the heater element is on   switching on this accessory may cause the heater to loadshed  amp  switch off  This is to keep the total  power load to a safe level     Davey   Repair or Replacement Guarantee    In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction  within two years of the date of original purchase due to faulty materials or manufacture  Davey will at  our option repair or replace it for you free of charge  subject to the conditions below     Should you experience any difficultie
10. ure  If this light is  flashing the water sensor is not detecting any water       Pump Light  The GREEN Pump indicator light will appear on the touchpad whenever the pump is  running  in both auto  amp  manual use mode       Heater Light  The RED Heater indicator light will appear on the touchpad whenever the heater element  is on  For safety the heater is always automatically controlled  Usually switching on the  air blower accessory will cause the heater to switch off  loadshedding   This is in order to  keep the total power load to a safe level  If this light is flashing the system has an error    see back page     AUTO SANITISING  FILTRATION    The Spa Power 500A Mk2 automatically maintains the filtration sanitation of the spa   pool water  The minimum amount of filtration time is programmable by the user  amp  can be  adjusted between 0  amp  15 minutes per hour  0 to 6 hours per day   In order to maintain  correct filtration of the pool water  the SP500A Mk2 monitors the time for which the pump  runs in normal pool operation  If the pump has only run for a short time  the system will  automatically run the pump for an additional period every hour to reach the minimum  filtration time set by the user     Adjusting Minimum Filtration Time  First push the Down v   amp  Air Aux    buttons together to display the filtration time    setting on the digital readout               Press both buttons  simultaneously        e  GRA POWER 600  The default setting is 10 minutes per ho
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Tamron AFB01C700 Camera Lens User Manual  お手入れと保管について  ASUS X72JR-TY123V notebook  SAP Business One  THE USER'S GUIDE FOR THE AUTHORS  5.8G H z w ireless A /V sen d er  Micromax X081 User Guide  ACTi INR-420  Télécharger le dossier de l`exposition  MANUAL DO USUÁRIO    Copyright © All rights reserved. 