Home
Algo 8028 SIP Doorphone User Guide
Contents
1. www algosolutions com 3226 3228 FXS Station Port Doorphone The 3228 emulates an analog telephone set allowing it to connect to an FXS gateway or telephone system analog station port Configurable for hotline or extension dialing Supplied with digital door station with both stainless steel and brass faceplates www algosolutions com 3228 Algo Communication Products Ltd Burnaby BC Canada V5J 5L2 www algosolutions com eee
2. S029 8028 SIP Doorphone Installation and User Guide Algo Communication Products Ltd Burnaby BC Canada V5J 5L2 www algosolutions com PN 90 00054C a q Important Safety Notice The 8028 SIP Doorphone is designed and tested to comply with EN 60950 1 2006 safety requirements When the Doorphone Controller is connected to wiring that exits the building there is potential risk of lightning induced electrical surges or high voltages from fault conditions To reduce risk outdoor wiring should be protected by Earth grounded conduit whenever possible If outdoor wiring will be connected to the Doorphone Controller then the power supply provided with the Doorphone Controller must first be connected to a properly Earthed mains supply Under no circumstances can the Doorphone Controller be disconnected from Earth ground while connected to outdoor wiring SSS Support Algo is pleased to offer telephone or email support relating to installation issues applications assistance or general product inquiries Algo Communication Products Ltd 4500 Beedie Street Burnaby British Columbia Canada V5J 5L2 support algosolutions com 604 454 3792 sales algosolutions com 604 454 3790 Algo products are warranted against defect in workmanship for a period of 12 months after installation not to exceed 18 months from date of manufacture FCC Compliance This equipment has been tested and found to comply with the limits for a Class
3. SIP Server check configuration On steady offhook or ringing state is currently active Door Ww e On steady when door station is connected Station Flashing indicates communication errors e On when Door Relay is activated 31 Connection Details Door Control Relay 24V 0 3A Terminal Bec fel Door Station Jack Center Pair Red Door Station RJ12 Telephone Jack Green e Middle Pair Dry Contact Input Yellow 8 Black Max 1 kQ Outside Pair Dry Contact Output Blue amp White Max 50 mA 30 V Ethernet Jack Connect to LAN with access to RJ45 Jack SIP compliant Proxy Server Reset Button To return all settings to a factory default press and hold the reset button at startup Continue to hold the button until all LEDs start to flash Door Station CTRL Connect to Door Station Jack 6 Position Terminal Block of Doorphone Controller IN Dry Contact Input to Door Station e g Door Contact Doorbell Switch Max 1 KQ OUT Dry Contact Output from Door Station e g Gate Control Max 50 mA 30 V E See Auxilary 1 0 on page 24 for more information on setting up auxiliary inputs and outputs 32 Connections and Lights Auxiliary Dry Contact Outputs Both the Doorphone Controller and Door Station provide a dry contact output for connection to auxiliary devices Maximum switching capacity is 30 V 50 mA Default operations are as follows e Doorphone Controller Output In Use commonly used for
4. camera control e Door Station Output Call Button Press commonly used to activate a secondary door bell Other options for Doorphone Controller output include Ring and Call Button Press Other options for Door Station output include In Use and Door Control Auxiliary Dry Contact Inputs Both the Doorphone Controller and Door Station can detect a dry contact closure from auxiliary devices A non capacitive and non inductive low voltage and low current is used to detect contact closure Default operations are as follows e Doorphone Controller input Door Sensor Normally Closed used to detect door open e Door Station input Call Button Normally Open used to detect external doorbell switch Options for Doorphone Controller input include Door Sensor Normally Closed Door Sensor Normally Open Manual Door Release Door Control Lockout Call Button Normally Closed and Call Button Normally Open Options for Door Station input include Door Sensor Normally Closed Door Sensor Normally Open Call Button Normally Closed and Call Button Normally Open a Specifications Compatibility Configuration Network Address NAT Network Address Translation Speech Codec Physical SIP Web Interface or TFTP Auto Provisioning DHCP or static IP address STUN Server or Keep Alive Full Duplex Capable G 711 Separate Controller and Door Station Controller Power Indicators Network Connection Installation Environmental Do
5. retraction of the latch bolt There are two different types of door strikes e Fail Locked or Fail Secure e Fail Unlocked or Fail Safe Fail Locked Fail Secure Electric Strike i A 24V 0 3A These require power to release and pue remain locked during power failure The door may still normally be opened from the outside with a key or from inside without a key The door control relay is used to apply power to release the door Fail Unlocked Fail Safe Electric Strike Door Strike Fail Locked 24 Vdc 0 2 A Typical r Pree These as well as magnetic locks require power to lock and become unlocked during power failure The door control relay is used to maintain power to the door lock NC and C contacts which is interrupted to release the door Magnetic locks may require override systems to allow safety exit in the event of fire Power Supply The Doorphone Controller provides an auxiliary 24 V 0 3 A power supply which is suitable for common types of door strikes If more current or a different voltage is required then the customer must provide a matching power supply for the electric strike or magnetic lock Maximum switching capability of the door control contacts is 1 A 30 V The Door Control relay may also be configured for alternate functionality including In Use Ring and Call Button Press For more information on applications for the 8028 SIP Doorphone please vis
6. voice and data Backlit tactile silicon rubber 6 Position terminal strip Controller Aux In Aux Out Flush or surface mounted using supplied plastic bezel Fits two gang electrical box NEMA 3R Rated for outdoor locations Ambient temperature 30 to 60 C Detects dry contact closure 5 V 1 mA sensing current Door sensor NC or NO Call button NC or NO Default Disabled Normally open switch 180 Ohms active Maximum 30 V 50 mA In Use Ringing Call button pressed Default Door gate unlock Door open requires door sensor Door alarm requires door sensor Door sensor NC Default or NO Follow Controller input Follow Door Station input Disabled Specifications are subject to change without notice Some features may only be avail able in specific firmware or hardware releases 35 Related Doorphone Products 8028V Tamper Proof SIP Doorphone z Same as the model 8028 SIP Doorphone with the w exception that the supplied digital door station is a special SO tamper proof design Suitable for environments where i 7 there is a high potential for attempted damage or abuse SS www algosolutions com 8028V Oly 3226 FXO Trunk Port Doorphone The 3226 emulates a Central Office CO telephone line allowing it to connect directly to a FXO Gateway or telephone system analog trunk port Configurable ring cadence and CLID message Supplied with digital door station with both stainless steel and brass faceplates
7. we 32 Connection Details es iesriscsi retest Hotel ord eee seers ees aero 32 Auxillary Dry Contact Outputs 2 conccc4adietecca dug ad aneenkd erten eda ne Gan en oak 33 Auxillary Dry Contact INPU S ereer ote a nce Gah Se eens dod Era ea N ai 33 SDCCINCANONS e ceny prosas R boa e S 34 Introduction Ideal for secure business entrances emergency intercom and residential gates Algo s 8028 SIP Doorphone provides hands free intercom capability entrance security with door unlock control rugged weatherproof design and superior audio performance Fully compatible with SIP industry standards the 8028 SIP Doorphone will work with most hosted or enterprise SIP based servers supporting third party SIP endpoints The 8028 Doorphone includes a Control Unit Door Station and Power Supply The Control Unit and Door Station can be connected with a single twisted pair wire up to 1 000 feet 300 m with the Door Station located outdoors and the Control Unit in a dry indoor location Features e Suitable for commercial or residential applications e Door Station connected by a single twisted wire pair e Full duplex capable hands free voice communication at the Door Station e Door control relay contacts and available 24 Vdc 0 3 A strike power e Auxiliary dry contact inputs and outputs from Doorphone Controller and Door Station e Programmable via Web Interface e International 110 220 V 50 60 Hz switching power supply e Regulatory CS
8. 6 Typical Applications for Auxiliary Inputs and Outputs 0 0 0 0 ce ee 6 Door or Gate Control BasieS vs iia cdo Ceara a ee dee ee aww hw eee eds 8 Bos E ere ee pa ai Sew eset Grete Seek Siew eed alee 8 Setup and Installation ocsuccicecntes larisa id oia ee 10 Programming and Configuration ooooocoooc ee 11 Web Interface Control Panel 2 0 45 24 pss ees so SHG hs eee She oS wads oe eee 11 Basie SEMIN Su a ae ala de a we ew el ee ea ee ee ete la ee a 12 OUP cos tures oat pee ee pes ee ee a eee ee ee ee 12 Ue Lo 2 oe eee ewes be ereee ee 4S oe eee eee ee oe aioe oe eee oe Geeks Eas eee eee 18 DO Relays ost Bhatia Ae ad bao A Bai da bi ase adi das Bota dic a 14 Advanced Sengsara r dl cae eee cia a ae 16 o A cure bees ye ciao E Gueesie gt dere Bes Fe See GC E gare we ceeded baie e meee cae 16 E 18 Mi A O A nl a wwe SA ht Ar wth dna ks A 20 Generating a Configuration File naana aaa Rie Gaaee aces dan eee eRic g de Seam e oh 21 AR A UU E EE E S E a E E a a a a 22 PAY e e a e E nn 24 SCCO A o o EE E A E eee ore 26 Advanced SIP eris eaa s aa a Greaves ed E ae eee E R ut E 27 A E A E A eee eee eee A ees ee E ee E E ee ee ee 29 MAMENANG E ss sou epee E E eee tee ee T eee eee a he ee eee D 29 Upgrade FMI opa tie eee is ee RE va Cb oe eee aia oa 30 SVSICUTLOO ot porras eee ee aaa be boy eee eee al Pape eee ee 31 LED IONES 244254455084 y a ee ee sao e hee has Bek eee a a a ee a 31 Connections and LighisS coord A twee ees
9. A UL FCC Class B CE EN60950 1 2006 CB Scheme Quick Install amp Test The 8028 SIP Doorphone requires minimal configuration for a typical installation Programming is only required to enter the SIP account details and for more advanced applications 1 Connect the power supply to the Power Jack of the Doorphone Controller and plug into an available AC outlet Flush or surface mount the Digital Door Station at desired location and connect a twisted telephone wire pair between the CTRL terminals of the Door Station and the center pair red and green of the supplied Telephone Wiring Jack Polarity is not important Using the short six conductor modular cable connect the Telephone Wiring Jack to the Door Station Jack of the Doorphone Controller Using an Ethernet cable connect the Ethernet Jack of the Doorphone Controller to your LAN Press the Call Button on the Door Station A recorded voice will speak the IP Address of the device Enter this address in a PC web browser in order to open the Web Interface Note The spoken IP address feature will be automatically disabled after a SIP Server is configured in Step 6 below Use the Web Interface to enter the SIP Proxy Server address as well as the user account and password that the 8028 SIP Doorphone will use to register Also enter the target extension that the Doorphone will call Press the Call Button on the Door Station then answer to comm
10. B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected or 4 Consult the dealer or an experienced radio TV technician for help Table of Contents UDO be 0 3 rans eae cee ate Dub are eo ee ater ee ate 2nate Saar eee aes eat Saas ater a Aree ae er ue 2 eri AR bere be aca eene oh aa Barer al awe BM ra a oee ae oe eee 2 important Safety NOTES oe eseria adaa a Adan ar ee a A ao and Eee a ane 2 ess A te eee ee ee eee ee ae ee ee eee ees ee ee 4 Fo ee eee oes hehe Se wee eke ne oes ee ee EE eee ER a ee eee eee eee 4 Quick Install amp Test 0 cc eee eee eee 5 PODNCAUONS 3 ricas ae a A o eee seen eee
11. Door Alarm condition is detected based on the Max Door Alarm Open time above being exceeded then the 8028 can generate a notification call Call every e 2 min Default 1 hour e 10min e None e 30 min Door Station If a wiring fault occurs that breaks communication with the Door Disconnected Station then the 8028 can generate a notification call Call every e 2 min e 1 hour e 10 min e None Default e 30 min 26 Advanced SIP Status Basic Settings Advanced Settings Network Admin Provisioning Call Auxiliary I O Security Advanced SIP Advanced SIP Settings Here you can configure more SIP settings Outbound Proxy A STUN Server SSS Register Period seconds 3600 Keep alive Method None Double CRLF E NN A A E o Server Redundancy Feature Multiple Enabled Disabled SIP Server Support Backup Server 1 Backup Server 2 Polling Interval seconds 120 seconds 2 minutes Time period between sending monitoring packets to each server Non active servers are always polled and active server may optionally be polled see below Poll Active Server Enabled Disabled HExplicity poll current server to monitor availability May also be handled automatically by other regular events so can be disabled to reduce network traffic Automatic Failback Enabled Disabled Reconnect with higher priority server once available even if backup connection still fine Polling Method SIP NOT
12. IFY SIP OPTIONS SIP message used to poll servers to monitor availability 27 Outbound IP address for outbound proxy A proxy server stands between a Proxy private network and the internet STUN Server IP address for STUN server if present Register Period Maximum requested period of time where the 8028 will re register seconds with the SIP server Default setting is 3600 seconds 1 hour Only change if instructed otherwise Keep alive If Double CRLF is selected the 8028 will send a packet every 30 Method seconds unless changed to maintain connection with the SIP Server if behind NAT Server Two secondary SIP servers may be configured The 8028 Redundancy will attempt to register with the primary server but switch to a Feature secondary server when necessary The configuration allows re registration to the primary server upon availability or to stay with a server until unresponsive Backup Server If primary server is unreachable the 8028 will attempt to register 1 with the backup servers If enabled the 8028 will always attempt Backup Server to register with the highest priority server 2 Polling Interval Time period between sending monitoring packets to each server seconds Non active servers are always polled and active server may optionally be polled see below Poll Active Explicitly poll current server to monitor availability May also be Server handled automatically by other regular events so can
13. Inbound Call e Enabled Default e Disabled Answer Tone An optional beep tone can be played at the Door Station when it answers an inbound call e Enabled Default e Disabled Outbound Ring Cancel dial attempt if call is not answered within specific duration e No ring e Limit to 1 9 rings Default 5 Rings e No limit Cancel if Door Cancel dial attempt if door has been opened before call is Opened answered Only available if the controller input or door station input is configured for Door Sensor mode and a physical sensor is available at the door e No Default e Yes Allow Call If enabled allows visitor to end an active call by pressing the Call Button Button to End Call e Enabled e Disabled Default Maximum Call Select the maximum call duration before the call will be Duration terminated oe Auxiliary I O Status Basic Settings Advanced Settings System Logout or Admir Provisioning er Auxiliary I O gt curity Advancec Auxiliary Input Output Settings Here you can configure auxiliary input output settings Controller Output In Use M Door Station Output Call Button Press y Door Relay Door Control v In Use Definition call Connected call Ringing or Connected Controller Input Door Sensor Normally Closed Input y Call Button Normally Open Input y Door Station Input 24 Controller and Door Station Output Options Door Relay In Use Definition Controller Input Do
14. Settings System Logout Maintenance System Log About 2 Inthe Maintenance section click Reboot Reboot the device Ey Reboot Wait 30 60 seconds for the device to reboot and the web page to automatically reload 3 Login to the device again and click on System 4 Inthe Upgrade section click on Choose File and select the 8028 firmware file to upload Note that both the FW firmware and MD5 checksum files must be pacer Method From Local Files From URL Firmware Image Choose File No file chosen MD5 Checksum Choose File No file chosen Upgrade gt Upgrade 5 Click Upgrade 6 After the upgrade is complete confirm that the firmware version has changed refer to top right of Control Panel 30 System Log Status Basic Settings Advanced Settings System Logout Maintenance System Log About System Log Part 1 gt Download log1 txt Download log2 txt gt View All Use on the advice of Algo technical support only View All LED Details Power On steady Power is OK but Ethernet Link not established O Blinks one second on one second off Ethernet Link status OK but IP Address not yet obtained Light on blinks off briefly every two seconds Link and IP Address established successfully Telephone Off Not registered with SIP server Light on blinks off briefly every two seconds Successfully registered with SIP Server ready for use Blinks one second on one second off error registering with
15. ace tool accessed by entering the 8028 IP address into a browser Using this interface you can configure the 8028 network settings and select the desired options These settings survive power cycling and may be programmed in advance prior to site installation Basic Settings SIP SIP Settings Here you can configure the basic SIP settings i Default port is 5060 To specify a different port enter PROXY PORT e g my_proxy com 5070 or 192 168 1 10 5080 Extension A Authentication 1D A Authentication Password C Dialing Extension i Phone number to be dialed when the call button on the door station is pressed SIP Domain SIP Server Name or IP address Proxy The phone number that the 8028 registers with the SIP Server It will auto answer any inbound calls Auth ID Authentication ID Used to register the device on the SIP Server SIP password used to register the device on the SIP Server Dialing Phone number to be dialed when the Call button on the door Extension station is pressed _12 Audio Status Basic Settings Advanced Settings System Logout SIP Audio Door Relay Audio Settings Here you can configure audio settings E Audio A A A AA A A A AAA A A is iii Speaker Volume ei Microphone Volume Ringback Tone Enabled Disabled Speaker Volume Speaker audio level in 3 dB steps Default 8 Microphone Microphone audio level in 3 dB steps Default 7 Volume Ringback Tone Allows audible ringback tone t
16. be disabled to reduce network traffic Automatic Reconnect with higher priority server once available even if Failback backup connection still fine Polling Method SIP message used to poll servers to monitor availability 28 System Maintenance System Maintenance na Backup Restore Configuration A A A A A A A A A eiea otitisa n ceti etidan citei Download Configuration File gt Backup Restore Configuration File Choose File No file chosen gt Restore Restore Configuration to Defaults E yRestore Defaults a Reboot A A beads dees idee eee aaite intier Deedul eels Bicsetoees tees dee beaut beeee Secee poet eeea dees badee bees lseeu beet paedc cease toed bees Deca ni aai Reboot the device Ey Reboot Buses Upgrade to New Firmware A A A A A A A A A A A A o Method From Local Files From URL Firmware Image Choose File No file chosen MD5 Checksum Choose File No file chosen Upgrade gt Upgrade Download Save the device settings to a text file for backup or to setup a Configuration provisioning configuration file File Restore Restore settings from a backup file Configuration File Restore Resets all 8028 device settings to factory default values Configuration to Defaults Reboot the Reboots the device Device This is the firmware image and checksum as provided by Algo MD5 Checksum 29 Upgrade 8028 Firmware 1 From the top menu click on System then Maintenance Status Basic Settings Advanced
17. d Local Network Both High Availability Hardware Watchdog OEnabled Disabled 18 Password Password to log into the 8028 web interface You should change the default password in order to secure the device on the network If you have forgotten your password a soft reset will restore the default setting including all of the device s default settings To do this first disconnect power from the 8028 Doorphone Controller Then press and hold the Reset button on the back of the device and while doing this reconnect the power Continue to hold the Reset button until the LEDs on the front of the controller start to flash Re enter password to log into 8028 web interface Device Name Name to identify the device in the Algo Network Device Locator Tool NTP Time Allows the 8028 to synchronize to an external time server Server Introduction Section on Allows the introduction text to be hidden from the login screen Status Page Log Level Amount of information provided in the log files This value should only be changed if advised by Algo Log Size Amount of internal memory reserved for recording log file Default is 100 kB Log Method Sets storage location of log file data Default setting is Local Choose Network or Both to send log messages to any Syslog server an option to prevent loss of data during a powerdown Hardware Use on the advice of Algo technical support only Watchdog SNMP Support Additi
18. ficient time for entry For security the 8028 Doorphone can be configured to cancel Door Opening once the door is opened to prevent tailgating by unauthorized personnel Unlock Door Indefinitely until Canceled The door opening control can be set to unlock indefinitely using the Latch Open Code until canceled using the Release Code that locks it again This allows an entrance to be used repeatedly for a period of time without requiring multiple activations of the door control relay Anti Door Tamper A feature of the 8028 Doorphone is to ring the telephone s with a warning alert in the event a door is ajar due to tampering Such as a door blocked open after being legitimately released for a visitor In Use and Ring Either the Control Unit or Door Station can be configured to provide a dry contact output during ring or in use for channel selection typically of third party video monitoring systems Door or Gate Control Basics Control contacts are provided from the Doorphone Controller and are typically used for door strike activation or gate control For security the door control relay is located in the Controller to avoid entry by tampering The Door Station dry contact output OUT may be configured for low security gate control requiring a low current dry contact Door Release Door release typically involves energizing or de energizing a door strike which pivots to allow a locked door to open without
19. from il DHCP must be enabled if using DHCP Option 66 in order for Provisioning to work One of two files can be uploaded on the Provisioning Server for access via TFTP FTP or HTTP 1 generic file algop8028 conf or 2 specific file algom MAC conf 20 MD5 Checksum In addition to the conf file an md5 checksum file must also be uploaded to the Provisioning server This checksum file is used to verify that the conf file is transferred correctly without error A tool such as can be found at the website address below may be used to generate this file http www fourmilab ch md5 The application doesn t need an installation To use the tool simply unzip and run the application md5 from a command prompt The proper mab file will be generated in the same directory fh If using the above tool be sure to use the l parameter to generate lower case letters Generating a generic configuration file 1 Connect an 8028 on the network Access the 8028 Web Interface Control Panel Configure the 8028 with desired options Click on the System tab and then Maintenance Click Backup to download the current configuration file Save the file settings txt Rename file settings txt to algop8028 conf 9 A CP Oo 2 CN File algop8028 conf can now be uploaded onto the Provisioning server des Backup Restore Configuration O OO DO OOOO a a a Download Configuration File P Backu p Restore Configuration File Choo
20. it 4 www algosolutions com 8028 The 8028 Doorphone firmware may be modified through the web interface and Algo routinely accepts requests for custom firmware for unique applications Setup and Installation 8028 SIP Doorphone Controller y Door Control Relay Reset Button see Door Control Section Power Input 24V 0 6A Door Station Jack 6 Wire Modular SS Ethernet Jack Connect to Cable Supplied LAN with access to SIP Proxy Server Telephone Wi ring WHITE BLUE Jack supplied Su Controller Dry Contact Output Controller Dry Contact Input Twisted pair typical 24AWG gt Max 1000 feet 300m Station Dry Contact Input Door Station Station Dry i Contact Output OH JO Programming and Configuration Connection to Network and Obtaining IP Address After connecting the 8028 to a network port watch for the PWR light to start winking on and blinking off during initialization The 8028 will then attempt to obtain an IP address from the DHCP server If unsuccessful the 8028 will default to the fixed IP address 192 168 1 111 To find the IP address of the 8028 press the Call Button on the Door Station The 8028 will speak its IP address if it has not yet been configured with a SIP Server address Alternatively search the network using the 8028 Locator Tool available for download from www algosolutions com 8028locator Web Interface Control Panel The 8028 is programmed using a web interf
21. o be played on Door Station speaker until call is answered e Enabled Default e Disabled oe ieee Door Relay Settings IAN Basic Settings O ANOS go Door Relay Door Relay Settings Here you can configure door relay settings Momentary Open Code Duration Cancel if Door Opened Latch Open Code Latch Closed Code DTMF Detection Type Allow Network Control i Max 4 digits Oves Ono AAN i Max 4 digits SESE i Max 4 digits SAuto ORTP Out of band RFC 2833 ORTP In band OSIP INFO yes ONo Allow auxiliary relay control by network command Contact support for more information 14 Momentary 1 4 digit DTMF code that can be used to unlock the door for a Open Code brief period of time as set by the Relay Time field Leave this field blank to disable this feature Default 6 The duration for which to unlock the door when the Momentary Open Code is entered Cancel if Door Cancels the door unlock i e locks the door again if the door Opened has been opened to ensure it cannot be opened a 2nd time Only available if the controller input or door station is configured for Door Sensor mode Latch Open 1 4 digit DTMF code that can be used to unlock the door Code indefinitely Leave this field blank to disable this feature Latch Closed 1 4 digit DTMF code that will lock the door again when it is Code latched open Leave this field blank to disable this feature DTMF Detection U
22. onal SNMP support is anticipated for future but the 8028 v1 get only now responds to a simple status query for automated supervision Contact Algo technical support for more information Provisioning Provisioning allows installers to pre configure 8028 units prior to installation on a network It is typically used for large deployments to save time and ensure consistent setups Status Basic Settings Advanced Settings Network Admin Provisioning Call Auxiliary I O Security Advanced SIP Provisioning Settings Here you can configure settings for provisioning function ded Mode oa AIE EST A A a EE AMA A A GA E AAA AA A AAA AA AAA AA AA AAA A Aoa E ii Provisioning Mode Enabled ODisabled PAAA Settings FR A SEEE PASE RAS AEEA AA AEREA SEE A A A A SN Ne ERE E AEA PN E AAAA SEEE AA EEE A AARE ASAE EA EA AEEA A A AEEA OEE A EA A OSE OR A Pn Server Method DHCP Option 66 OStatic Download Method STFTP OFTP OHTTP Config Download Path A Firmware Download Path AA There are two different Provisioning methods that can be used via DHCP Option 66 or via a Static Server In addition there are three different ways to download provisioning files from a Provisioning Server TFTP Trivial File Transfer Protocol FTP or HTTP For example 8028 configuration files can be automatically downloaded from a TFTP server using DHCP Option 66 This option code when set supplies a TFTP boot server address to the DHCP client to boot
23. or Control Connection Door Control Power Door Control Relay Door Station Connection Door Station Wiring Auxiliary Input Connection Auxiliary Input Electrical Auxiliary Input Functions Auxiliary Output Connection Auxiliary Output Electrical AC Mains Adapter 95 230 V 50 60 Hz Included Power Door Station Status In Use Door Unlock RJ45 Jack Shelf or wall mounted Dry indoor location 5 Position terminal strip Available 24 V 300 mA Strike power Relay C NO NC phone keypad activated Maximum 30 V 1A RJ12 Jack Center Pair 24 AWG Twisted Pair to 1000 Ft 300 m RJ12 Jack Second Pair Detects dry contact closure 24 V 4 mA sensing current Manual door release Door control lockout Door sensor NC Default or NO Call button NC or NO Disabled RJ12 Jack Outside Pair Normally open switch 180 Ohms active Maximum 30 V 50 mA 34 Auxiliary Output Functions In Use Default Ringing Call button pressed Door unlock Door open requires door sensor Door alarm requires door sensor Door sensor NC Default or NO Follow Controller input Follow Door Station input Disabled Door Station Power Wiring Signalling Call Button Connections Installation Environmental Auxiliary Input Electrical Auxiliary Input Functions Auxiliary Output Electrical Auxiliary Output Functions Provided by Controller link Up to 1 000 Ft 300 m 24 AWG single twisted pair to controller Digital link bi directional
24. or Station Input In Use Default Follow Controller Input Dial Follow Station Input Call Button Press Disabled Door Control Door Sensor Door Alarm In Use Door Alarm Dial Follow Controller Input Call Button Press Follow Station Input Door Control Default Disabled Door Sensor Call Connected Active from call answer to end of session Call Ringing or Connected Active from button press to end of session Door Sensor Normally Open Input Door Sensor Normally Closed Input Default Manual Door Release Input Door Control Lockout Input Call Button Normally Open Input Call Button Normally Closed Input Disabled Door Sensor Normally Open Input Door Sensor Normally Closed Input Call Button Normally Open Input Default Call Button Normally Closed Input Disabled 25 Security Status Basic Settings Advanced Settings System Logout Network Admin Provisioning Call Auxiliary I O Security Advanced SIP Security Settings Here you can configure security settings bo AY Max Door Open Door Open Alarm Door Station Disconnected Max Door Open Ifthe Controller or Door Station input is connected to a physical door sensor and also configured in Door Sensor mode See Auxiliary I O Settings on page 31 then a Door Alarm condition can be triggered if the door remains open for longer than a threshold of e 30 sec e 60 min e 2 min e 90 min e 15 min e 120 min e 30 min e None Door Open When a
25. se File No file chosen P Restore Restore Configuration to Defaults y Restore Defaults 2 lt If using a generic configuration file extensions and credentials have to be entered manually once the 8028 has automatically downloaded the configuration file Generating a specific configuration file 1 Follow steps 1 to 6 as listed in the section Generating a generic configuration file on page 21 2 Rename file settings txt to algom MAC address conf e g algom0022EE020009 conf 3 File algom MAC address conf can now be uploaded on the Provisioning server The specific configuration file will only be downloaded by the 8028 with the MAC address specified in the configuration file name Since all the necessary settings can be included in this file the 8028 will be ready to work immediately after the configuration file is downloaded The MAC address of each 8028 can be found on the back label of the unit Call Status Basic Settings Advanced Settings System Logout Network Admin Provisioning Call Auxiliary I O Security Advanced SIP Call Settings Here you can configure call settings oe A a ana EN A A Te RT Answer Inbound Call Enabled ODisabled Answer Tone Enabled ODisabled A E A OA A Outbound Ring Limit 5 rings y G 1 ring 6 seconds Cancel if Door Opened Oves Ono Allow Call Button to End Outbound Call OEnabled Disabled AAA Maximum Call Duration Answer Auto answer or ignore inbound calls
26. se the default of Auto unless advised by Algo technical support Type Allow Network Allows auxilary relay control by network command Contact Control support for more information Advanced Settings Network Status Basic Settings Advanced Settings system Logout Network Settings Here you can configure network settings Protocol static IP DHCP IP Address 10 0 0 102 Netmask Gateway DNS Server A VLAN Mode VLAN ID VLAN Priority SIP 6 bit DSCP value RTP 6 bit DSCP value DHCP Timeout seconds DHCP is an IP standard designed to make administration of IP addresses simpler When selected DHCP will automatically configure IP addresses for each 8028 on the network Alternatively the 8028 can be set to a static IP address Enables or Disables VLAN Tagging VLAN Tagging is the networking standard that supports Virtual LANs VLANs on an Ethernet network The standard defines a system of VLAN tagging for Ethernet frames and the accompanying procedures to be used by bridges and switches in handling such frames The standard also provides provisions for a quality of service prioritization scheme commonly known as IEEE 802 1p and defines the Generic Attribute Registration Protocol Specifies the VLAN to which the Ethernet frame belongs A 12 bit field specifying the VLAN to which the Ethernet frame belongs The hexadecimal values of 0x000 and OxFFF are reserved All other values may be u
27. sed as VLAN identifiers allowing up to 4094 VLANs The reserved value 0x000 indicates that the frame does not belong to any VLAN in this case the 802 10 tag specifies only a priority and is referred to as a priority tag On bridges VLAN 1 the default VLAN ID is often reserved for a management VLAN this is vendor specific Sets the frame priority level Otherwise known as Priority Code Point PCP VLAN Priority is a 3 bit field which refers to the IEEE 802 1p priority It indicates the frame priority level Values are from O lowest to 7 highest These values can be used to prioritize different classes of traffic voice video data etc Can provide quality of service if the DSCP protocol is supported on your network Can be specified independently for SIP control packets versus RTP audio packets Length of time following a request from an 8028 to the DHCP server that the 8028 will wait before assuming the server is not available After such time the 8028 will use its default address of 192 168 1 111 Default is 60 seconds Admin Basic Settings Advanced Settings Sys Logout Admin gt rovisioninc a xiliarw 1 0 Admin Settings Here you can configure admin settings Password Confirmation General Device Name Hostname NTP Time Server Introduction Section on Status Page Log Level OError Lowest ONotice Event Olnfo SIP Debug Highest Log Size 1 1000 kB Log Metho
28. unicate with the Door Station Press the digit 6 on the phone keypad to activate the door control relay for three seconds if applicable 5 Applications Typical Applications for Auxiliary Inputs and Outputs The 8028 architecture and digital link between the Door Station and Controller provides flexible options using the auxiliary inputs and outputs These are some typical applications Cancel Ring When Door Opened In a residential or warehouse installation it is not uncommon for the door to be answered in person before the phone is answered Either Door Station or Control Unit inputs can be configured to cancel ring if the door is opened before a call is answered This requires a normally closed or normally open contact to detect door open Trigger Door Bell from Door Station When the Door Station call button is pressed either or both the Door Station or Control Unit dry contact output can be configured to activate a door bell or auxiliary alerting system in addition to phone ring Trigger Door Station from External Button Event Either the Control Unit or Door Station can accept a dry contact closure to activate the Doorphone as if the call button had been pressed This could be an external doorbell button PIR detector or some other system Cancel Door Open Relay once Door Opened The door opening control can be set for activation using the Open Code up to 30 seconds set by the Relay Time setting to allow suf