Home
CalChek with the Defender Operating Instructions 38046 PDF
Contents
1. Operating Instructions Tel 724 941 9701 Fax 724 941 1369 e mail skctech skcinc com CalChek with the Defender The CalChek Communication Cable provides direct communication between a CalChek compatible SKC AirChek 2000 or Leland Legacy sample pump and a Defender primary standard flowmeter Sample media on a Defender A suction port T a he Se Pump data port i CalChek Communic ati t e 2000 Pump and Defender Flowmeter in a CalChek calibration train Connecting Defender and Pump Pneumatically See individual pump operating instructions for details 1 Use inch tubing to connect the Defender suction port to the CalChek compatible pump inlet Calibration may require sample media in line See individual pump operating instructions for details 2 Run the sample pump for 22 minutes for stabilization Selecting Defender Data Port 1 Press and hold the Defender power button to turn on the flowmeter 2 Press the right arrow to highlight Setup press Enter 3 Press the right arrow to highlight Preferences press Enter 4 Press the down arrow to navigate to Data Port 863 Valley View Road Eighty Four PA 15330 USA 5 Press the left or right arrow to toggle to SKC 6 Press the down arrow to highlight Confirm press Enter The display will return to the Setup menu Entering Defender Calibration Mode 1 Press the right arrow and then the down arrow to highlight Measure press Enter 2 Press the rig
2. ht arrow to highlight Cont press Enter Using the CalChek Communication Cable 1 Attach the female end of the CalChek Communication Cable to the serial port RS 232 on the back of the Defender flowmeter 2 Insert the male end of the CalChek Communication Cable into the data port on the sample pump 3 Set sample pump to CalChek mode and select single point or full multiple point calibration see individual pump operating instructions Note The Defender flowmeter will begin to automatically calibrate the pump The initial flow measurements are taken without flow from the pump and the pump flow rate is adjusted automatically 4 When calibration is complete the pump will return to normal operation 5 Disconnect the CalChek Communication Cable and tubing Notice This operating instruction may not address all safety concerns if any associated with this product and its use The user is responsible for determining and following the appropriate safety and health practices and regulatory limitations if any before using the product The information contained in this document should not be construed as legal advice opinion or as a final authority on legal or regulatory procedures Form 38046 Rev 0902
Download Pdf Manuals
Related Search
Related Contents
ICA H & S Manual Installation Manual BACnet I/O Modules - mbs Asrock 870 Extreme3 Cherry MW 3000 CS-210の取扱説明書 Copyright © All rights reserved.
Failed to retrieve file