1. C S Installation and quaSaver Operating Instructions Surface Pumps Introduction The AcquaSaver valve is a fully automatic mechanical rainwater mains water changeover device designed for pressure pump supply systems for harvesting rainwater for the toilet laundry and household applications with automatic mains backup The AcquaSaver valve is designed to operate with a pump with an electronic pressure controller with auto restart not requiring a float switch The AcquaSaver valve can also operate with any pump with a pressure controller with or without a float switch Operation The AcquaSaver valve will always prioritize the use of rainwater over mains water when rainwater is available and will automatically switch over to mains water in the event of the rainwater tank running low or electrical failure When water has been replenished or power has been restored to the pump the AcquaSaver valve will automatically prioritize back to rainwater The pump is only active when rainwater is being drawn from the water tank it does not operate when the AcquaSaver valve has switched to mains position The pump controller starts and stops the pump when it detects a demand for example flushing a toilet or using a washing machine The operating mechanism of the AcquaSaver valve is a unique patent design it works by hydraulic water pressure created by the pump to close one inlet fully before opening the other inl
2. Pa Max pump pressure 700 KPa Max flow rate 100 LPM Cold water applications only Rainwater Inlet 25mm 1 BSP F Mains Water in 20mm 3 4 BSP F Outlet 20mm 3 4 BSP F Weight 2 2 kg Certified to WaterMark ATS 5200 477 WMK 60075 Complies with AS NZS 3500 1 when installed by a licensed plumber NOTE According to AS NZS 3500 1 maximum allowable pressure in buildings is 500 KPa 1 BSP F Loose Nut Mains Water In lt Fiber Washer To House p PRESSCONTROL Rainwater Tank Fig 3 200 mm minimum Mains Water In PEETA Float Switch T AcquaSaver sian O Pressure Controller 450 mm minimum B h T TEA Y Strainer A 100 mm above outlet minimum Isolation Valve Suction Hos Fig 4a Piggy Back Plug Fig 4b J Dumping Valve Pipe NOTE A dumping of a small amount of rainwater from the dumping valve pipe is normal during changeover back to mains water E g When rainwater tank is empty or there is no electrical power O Submersible Pumps Connection Fig 1 All plumbing connections should be carried out by a licensed plumber i gt Step 1 Fill pip
3. e with water until full to remove air before connecting AcquaSaver Valve as shown in Fig 1 Step 2 The AcquaSaver Valve is fitted onto a 1 BSP male union fitted on top of pipe Fig 2 lock up tight the 1 BSP F loose nut with the fibre washer supplied Step 3 Connect mains water to the AcquaSaver Fig 3 using the 3 4 BSP F connection 1O Step 4 Connect outlet to the household Fig 3 using the 3 4 BSP F connection A Rigid Pipe Warning Mains water should flow through AcquaSaver Valve before pump is turned on to avoid air being trapped in pipes Rainwater Tank DOU LOLUN Submersible Pump with built in controller 1 BSP F loose Nut Fiber Washer Fig 2 Fig 3 E AcquaSaver Valve Mains Water In qm Dumping Valve Pipe To House m Rainwater Tank 1 Rigid Pipe TOO COOOL Submersible Pump J with built in controller Parts List 170 160 12 Fiber Washer 1 N A N A 11 M6 Screws 4 Stainless Steel N A 10 Dumping Valve Pipe 1 Anti UV Elastollan Tube PU 1198 9 Copper Pipe 1 Copper Nickel Plated N A 8 Pus
4. et without restriction of flow This ensures an extremely reliable mechanism using few moving parts no electronic components and no energy consumption Features Easy to install Patented design Does not require maintenance No electrical consumption No electronic components Solid brass construction Fully weatherproof Built to last Suitable for any pressure pump with sufficient head pressure Can be mounted in any position Dual check valve for back flow prevention WaterMark Approved Manual override 2 Year warranty Connection All plumbing connections should be carried out by a licensed plumber Step 1 The AcquaSaver Valve is fitted onto the pump controller as shown in Fig 1 Lock up the 1 BSP F loose nut with the fibre washer supplied Step 2 Connect mains water to the AcquaSaver Fig 2 using the 3 4 BSP F connection NOTE Mains water should flow through AcquaSaver Valve before rainwater to avoid air being trapped in pipes Step 3 Connect outlet to the household Fig 2 using the 3 4 BSP F connection Step 4 Installation of float switch refer to Fig 3 NOTE When using a float switch with a piggy back plug Fig 4a plug into electrical outlet and pump lead into the back of piggy back plug Fig 4b Connection of the pump should be carried out to manufacturers instructions It is recommended a Y Strainer be fitted between the tank and pump Specications Max mains pressure 500 K
5. h Fit Union 1 DR Brass Nickel Plated MA 12 08 14 7 Push Fit Elbow 3 DR Brass Nickel Plated MA 16 08 14 6 Check Valve 1 DZR Brass 20 CVF 5 Dual Check Valve 1 DZR Brass 7179 4 Nut amp Tail Assembly il DZR Brass WDV NT2520 3 Dumping Valve 1 Brass Nickel Plated MV 27 00 14 2 Actuator Body 1 DZR Brass WDV CBA 1 3 Way Ball Valve 1 DZR Brass F32TBT020 No Component Qty Material Part No Trouble Shooting Symptom Cause Remedy No water is delivered from pump Rainwater tank is empty Wait for tank to fill No water is delivered from mains No Power Isolation Valve is shut Pump is not primed Incorrect Instalation of float switch Y Strainer is blocked No water from mains Air Lock Mains pressure above 500 KPa Dumping valve pipe blocked Check power supply amp plug Restart pump Open isolation Valve See pump owners manual on priming pump Refer to instalation instructions Clean Y Strainer Check isolation valve on water meter Manually override Install a pressure limiting valve manually override Remove blockage Pump continually runs Leak in the plumbing system E g Toilet or tap leaking Repair Leak Maintenance The AcquaSaver Valve does not require any maintenance however there are things you can do to ensure its most reliable operation Fit a Y Strainer Cleaning your gutters Cleaning the inlet strainer on rainwater tank