Home

OPERATING INSTRUCTIONS

image

Contents

1. disconnect the BLACK clamp first and return to its stored position on the Jump Start Unit Disconnect the RED clamp and return to its stored position on the Jump Start Unit Connect the Jump Start Unit to 240 volts for re charging See Charging the Unit from 240 Volt Supply above NOTE Much of the trouble experienced starting the Cat 9 is attributed to not allowing time for the glow plugs to warm by leaving the ignition switch in the ON position for a while This is an ol girl 1982 model Information about glow plugs is at http en wikipedia org wiki Glowplug NO m JUMP STARTING NERRIGUNDAH 7 12 VOLT SYSTEM Turn off ignition switch all radios and other switches such as working lights etc Locate the batteries on the LHS of the vehicle under the tray Note that Nerrigundah7 operates on a 12 volt doubled capacity system achieved by connecting two 12 volt batteries in parallel See http www zbattery com Connecting Batteries in Series or Parallel for an explanation To access the batteries tap open the tapered locking pin and slide out the batteries 2 3 inches Care is required not to slide too far out as live cables remain connected The positive battery terminals are located furthest in unfortunately Remove the 2 wingnuts and washers holding the plastic cover and lift the cover clear A mm er a 12 13 14 Connect the RED Jump Starter Clamp to either of the Positive battery terminals C
2. OPERATING INSTRUCTIONS 12V 24V Dual Voltage Jump Starter Used for all size cars trucks bus 12DC Power Supply 2 x 18AH battery Professional gauge indicator Multi voltage warning safe system Starting current 12V 700 AMP 24V 500AMP Peak current 12V 1500AMP 24 V 1000AMP Cold Cranking AMPS 350CCA PLEASE NOTE The following information is provided specifically for the use of Nerrigundah Brigade Members Whilst information has been sourced from the owners manual provided it has been interpreted and targetted for use specifically on our Category7 and 9 appliances No responsibility will taken for injury or loss from use of the information by others GENERAL The Jump Starter Unit has been designed as a portable jump start system for both 12 and 24 volt systems Both Nerrigundah Cat 9 and Cat 7 appliances have 12 volt systems Note that not all Cat 7 appliances have 12 volt systems There is a 3 way voltage selector switch on the front of the unit This switch should normally be in the OFF position and the apppropriate voltage selected for jump starting ONLY after the battery clamps have been correctly connected to a vehicle OR when the unit is being charged from a 240 volt supply See Charging Also on the front of the unit is a colour coded voltage meter that indicates the charge level of the unit s battery when the red button is pushed The battery clamps should always be stored clipped to the sides of the uni
3. onnect the BLACK Jump Starter Clamp to a non moving metal part of the body NOT TO THE NEGATIVE BATTERY TERMINALS Turn the Jump Start Unit s Selector Switch to the 12 Volt position Wait about 2 minutes whilst the vehicle battery accepts some charge Attempt to start the vehicle for no more than 5 6 seconds Wait at least 3 minutes before cranking again Once the engine is running disconnect the BLACK clamp first and return to its stored position on the Jump Start Unit Disconnect the RED clamp and return to its stored position on the Jump Start Unit Carefully slide the batteries back into position and replace the tapered locking pin Replace the plastic battery cover and tighten the wingnuts 15 Connect the Jump Start Unit to 240 volts for re charging See Charging the Unit from 240 Volt Supply above
4. t as shown in the picture unless being used for jump starting CHARGING THE UNIT FROM 240 VOLT SUPPLY Place the Voltage Selector Switch in the 12 VOLT POSITION Plug the charger jack into the socket in the unit front panel and connect to 240 volt supply 3 Switch on the 240 volt switch and continue to charge until the voltmeter indicates full capacity in the green area when the test button is pushed IMPORTANT do not stop charging before the meter indicates FULL capacity in the green area 4 When the 240 volt supply is turned off and disconnected return the Voltage Selector Switch to the OFF position The unit can remain plugged into the power socket indefinitely as there is an automatic Float Charging Circuit which will not allow an overcharge condition or damage to the unit s battery NO m JUMP STARTING NERRIGUNDAH 9 1 Turn off ignition switch all radios and other switches such as working lights etc pA 3 oe a 10 11 Connect the RED Jump Starter Clamp to the Positive battery terminal Connect the BLACK Jump Starter Clamp to a non moving metal part of the engine NOT TO THE NEGATIVE BATTERY TERMINAL Turn the Jump Start Unit s Selector Switch to the 12 Volt position Wait about 2 minutes whilst the vehicle battery accepts some charge Turn the ignition switch ON Attempt to start the vehicle for no more than 5 6 seconds Wait at least 3 minutes before cranking again Once the engine is running

Download Pdf Manuals

image

Related Search

Related Contents

Instructions  Life Fitness M051-00K58-A383 User's Manual  User Guide - Petplanet.co.uk  [c]FP-DO-401 Operating Instructions  Anbau-Buschholzhacker DTH80 ffl Betriebsanleitung - Agria  Solac PP7212  日本印刷産業連合会 「オフセット印刷サービス」グリーン基準  SmartMetals 092.0800 flat panel ceiling mount    製品安全データシート - 木材保護塗料 ウッドエイド  

Copyright © All rights reserved.
Failed to retrieve file