1.   avoid  pinching wires   Tighten down rod pin screw   Secure down rod with the other shorter down  rod screw provided    d  Slide on canopy cover and refit the ball joint     If an extension rod needs to be installed  please go to page 9     STEP 2  Fig  2    a  Drill a hole in the timber nogging for wiring   b  Use the two hex screws to secure the hanger  bracket onto the timber nogging  The timber  nogging should be supplied by the installing  electrician and must be supported between the  two ceiling joists as shown in the diagram  above     STEP 3  Fig  3    a  TIGHTEN THE GRUB SCREW     This is important to ensure the fan will not  wobble and the weight of the fan is supported    b  Hang the ball joint into the hanger bracket   Ensure the groove on the hanger bracket is  locked into the slot on the ball joint     1  Do not attempt to operate the fan  or optional light kit  with any wall control that is not  approved by Hunter Pacific for use with its fans  DO NOT use solid state controllers  The  use of unapproved controllers will void your warranty       2  Do not mix blade sets from one fan to another as this may upset the balance of the fan  If  WARNING only one blade is damaged you are still required to replace with a new set     HUNTER PACIFIC Electrician Installation Manual  Icon Ceiling Fan  IN TERNATIONAL    Assembling the fan    STEP 4  Fig 4 amp 5    a  Connect wires from the fan with wires in the ceiling via the  terminal block on the hanger bracket refer to 
2.   such as T hooks  are  available for certain types of installation    After installation  fan blades must be at least 2 1 m  7 feet  above floor level    The use of these products by children and the infirm must be under supervision        IF THERE ARE ANY PROBLEMS WITH THE PRODUCT AT TIME OF  INSTALLATION THE INSTALLER MUST CONTACT THE WARRANTY    HOT LINE NUMBER 1300 360 280  BEFORE LEAVING THE JOB    SITE  PLEASE DO NOT REMOVE THE FAN FROM THE CEILING  ONCE INSTALLED UNLESS INSTRUCTED TO DO SO     HUNTER PACIFIC Electrician Installation Manual  Icon Ceiling Fan  IN TERNATIONAL    Parts List   Icon Fan    _     Hanger Bracket    B             Hex Head Screw    Ball Joint    ee Canopy Cover    Motor Housing i    Base Plate      Blade Screw    Qty    ree  i erase  2     Down Rod Pin Screw   these parts come preassembled   Down Rod Short Screw       HUNTER PACIFIC    INTERNATIONAL    Electrician Installation Manual  Icon Ceiling Fan    Assembling the fan    Ball Joint    Canopy Cover    BS   Conn ction Collar  ih Ps  Wy  Motor Housing    a SS Fig  1   a R NS  _4 Down Rod Pin Screw         Hanger    Timber Nogging Bracket             STEP 1  Fig  1    PERFORM THIS STEP IF THE WIRES HAVE NOT  BEEN FED THROUGH THE DOWN ROD     a  Loosen the ball joint screw and remove the  ball joint pin to separate the down rod from the  ball joint    b  Feed wires from motor housing up and  through the down rod    c  Insert the down rod pin screw through the  connection collar and the down rod
3.  a  Fit the compact fluorescent light to the a  Turn the light to lock it to the light socket   light socket  b  Gently push the glass cover upwards and turn    it to attach the glass cover to the fan     1  Do not attempt to operate the fan  or optional light kit  with any wall control that is not  approved by Hunter Pacific for use with its fans  DO NOT use solid state controllers  The  use of unapproved controllers will void your warranty       2  Do not mix blade sets from one fan to another as this may upset the balance of the fan  If  WARNING only one blade is damaged you are still required to replace with a new set        8    HUNTER PACIFIC Electrician Installation Manual  Icon Ceiling Fan  IN TERNATIONAL    Attaching an accessory light kit     E14 Light  2 x 40W    STEP 1  Fig  17  Slightly push the base plate upward and turn until  tabs unlock to remove it     STEP 2  Fig  18   a  Using the connectors on the wires attach   the light wires from the motor housing to the light  wires on the light assembly     b  Attach and secure the light assembly kit using  the 3 screws provided     c  Install light globes into the light sockets     STEP 3  Fig  19  a  Once globes are installed  the glass cover can  be fitted on to the fan     b  Gently push the glass cover upwards and turn  it to attach the glass cover to the fan     4  Glass Cover       1  Do not attempt to operate the fan  or optional light kit  with any wall control that is not  approved by Hunter Pacific for use
4.  with its fans  DO NOT use solid state controllers  The  use of unapproved controllers will void your warranty       2  Do not mix blade sets from one fan to another as this may upset the balance of the fan  If  WARNING only one blade is damaged you are still required to replace with a new set        9    HUNTER PACIFIC Electrician Installation Manual  Icon Ceiling Fan  IN TERNATIONAL    Attaching an extension rod   Hunter Pacific rods to be used ONLY       Ball Joint   _ _ a       i   F    Loosen a  Ball Joint  Screw    Down Rod    Step 2  Fig  21   Loosen the ball joint screw  take out the ball joint  pin and remove the ball joint  Then slide off the  Step 1  Fia  20 Canopy Cover    Loosen and remove the down rod screws and   the down rod pin screw to remove the   standard down rod from the motor housing            Down Rod       Ball Joint Pin _    Ball Joint    Tighten Ball       Joint Screw    Down Rod a       Step 3  Fig  22  amp  23   Now install the extension rod and  reverse step 1  amp  2 to secure the rod to  the fan and the ball joint        NOTE  If the extension rod needs to be shortened  cut the rod to the required length and drill  the appropriate hole size to fit the ball joint pin  The cut end of the rod should be used at the ball  joint end only  When installing a 1 8m extension rod the wiring will need to be extended and  joined  This should be done using crimp style connectors        1  Do not attempt to operate the fan  or optional light kit  with any wa
5. Check wires in the terminal block are connected properly  connection wires  should be stripped back at the connection point and unused wires should be  sealed and capped off    Check that the reversing switch is pushed into its Summer or Winter position     Fan is not corresponding to the remote control    Check for flat battery  Make sure the dipswitch settings in the hand piece and the  remote receiver for the same fan correspond     Fan is wobbling    Check the ball joint slot is locked into the hanger bracket groove    Make sure blades are a matched set  the letters on matching sets of blades  should be identical with the numbers varying within 3 grams of each other   Check blade screws are tightened firmly  If necessary use balancing kit provided  to settle the wobble     Fan is noisy    WARNING       Check all screws and parts are secured firmly  Ensure there are no loose parts  moving inside the motor housing    Make sure the fan is installed with a Hunter Pacific wall controller only  do not use  solid state controllers as they can cause unpleasant motor noises     National Warranty Line 1300 360 280    Monday to Friday from 9am to 5pm EST  Only available within Australia      Do not attempt to operate the fan  or optional light kit  with any wall control that is not       approved by Hunter Pacific for use with its fans  DO NOT use solid state controllers  The  use of unapproved controllers will void your warranty     Do not mix blade sets from one fan to another as 
6. HUNTER PACIFIC Electrician  Installation Manual    Icon Ceiling Fan  IN TERNATIONAL    eon  FA       NOTE  The Icon light fitting does not come standard   however it can be bought as an accessory item     CEILING FAN MUST BE INSTALLED  BY A LICENSED ELECTRICIAN     NO OTHER PERSONS SHOULD ATTEMPT TO INSTALL THIS FAN        Electricians are recommended to tick off all items on the quick  checklist and fill out their details onto the back page of the Fan  Owner Warranty  amp  Operations Manual after installation    ELECTRICIANS   TO PROTECT YOUR CUSTOMER   S WARRANTY  PLEASE READ  PAGE 2 OF THIS BOOKLET PRIOR TO THE INSTALLATION OF THIS PRODUCT   National Warranty Line    1300 360 280    Monday to Friday from 9am to 5pm EST  Only available within Australia    Hunter Pacific International Pty Ltd  Building 8  256 New Line Road  Dural NSW 2158 Australia  ABN  18 063 521 666    HUNTER PACIFIC Electrician Installation Manual  Icon Ceiling Fan  IN TERNATIONAL    IMPORTANT INFORMATION  ELECTRICIANS MUST READ PRIOR TO INSTALLATION    1  Distributor and installer details and purchase receipts are essential for on site warranty claims  and must be presented to repair personnel  make sure you record your details in the Fan Owner  Warranty and Operations Manual     2  Fans and fixed wiring products must only be installed by persons who are appropriately licensed  by the applicable State regulatory body  Therefore  to protect our repair personnel  on site  warranty claims will not be accep
7. an is operating correctly on all three speeds using the wall control   ler     If light is installed  Check light switch is functioning properly     If remote control is installed  Check the fan  and light if installed  is responding  to the remote control correctly  Write Dip switch code in user guide     If remote control is installed  Check where possible a separate isolation switch  has been installed for the fan     Check electrician   s details have been recorded onto the back page of the  Owner   s Operations and Warranty Manual     12    
8. ate controllers  The  use of unapproved controllers will void your warranty     2  Do not mix blade sets from one fan to another as this may upset the balance of the fan  If  only one blade is damaged you are still required to replace with a new set     12    HUNTER PACIFIC Electrician Installation Manual    Icon Ceiling Fan    INTERNATIONAL    Quick Checklist    Electricians make sure everything on this checklist is ticked off before you leave the installation site   If you have trouble installing our product please refer to the trouble shooting section on the previous  page first then phone the Hunter Pacific Warranty Line on 1300 360 280  open 9am to 5pm EST    DO NOT uninstall the fan and DO NOT return fan to retailer     1     10     Ceiling fan is not installed to a solid state wall controller  Neither leading nor  lagging edge controllers will give satisfactory performance  Wall controllers    must only be types approved for use by Hunter Pacific International     The fan  optional fan light and bracket is earthed     Fan and optional fan light are run from the same final circuit     Mounting bracket must be firmly secured to a solid structure such as a concrete  ceiling  steel structure or timber framing  If additional bracing is added it must  be firmly secured to the rafters and not left floating on the ceiling  Special  mounts  such as T hooks  are available for certain types of installation     Fan blades are at least 2 1m   feet  above floor level     Check the f
9. e it     STEP 2  Fig  11   a  Use the connectors to attach the light wires  from the motor housing to the light assembly kit   b  Attach and secure the light assembly kit using  the 3 screws provided    c  Plug the light globe into the socket  DO NOT  touch the light globe with your fingers  It is  important to keep the globe clean or it will fail pre   maturely     STEP 3  Fig  12   Gently push the glass cover upwards and turn to  attach the light glass to the fan   a     Tab Slots   To     Do not attempt to operate the fan  or optional light kit  with any wall control that is not  approved by Hunter Pacific for use with its fans  DO NOT use solid state controllers  The  use of unapproved controllers will void your warranty        Do not mix blade sets from one fan to another as this may upset the balance of the fan  If  only one blade is damaged you are still required to replace with a new set     7    HUNTER PACIFIC Electrician Installation Manual  Icon Ceiling Fan  IN TERNATIONAL    Attaching an accessory light kit     GX 53M 14W compact fluorescent light                  STEP 1  Fig  13  a  Slightly push the base plate upward and turn until  tabs unlock to remove it     STEP 2  Fig  14   a  Using the connectors on the wires   connect the light wire from the motor housing with  the light wires on the light assembly    b  Attach and secure the light assembly kit using the  3 screws provided     p         Screws    PEREN Glass Cover   Light  STEP 3  Fig  15 STEP 4  Fig  16 
10. figure 4 and 5     b  Make sure earth wires are also connected     c  Connect light wires  red white  if a light fitting is going to be  used   Cap seal light wires if a light fitting is not going to be  used         eo    Green yellow          Oo r   rab  f   x z   O 2   2 S   Z  D Combi Separate     5 Control Control  FA LAE N      8      Separate terminal Fan Wiring Wiring for use with 3 pole block  For when 3 pole   Colours representative only  block is fitted    Separate terminal required for active    for light when 3 pole block fitted     STEP 5  Fig 6   a  Slide canopy up and over the hanger bracket    b  Twist the canopy to locate screws holes then loosen  canopy screws half way    c  Now twist the canopy to the opposite direction and  fully tighten screws until the canopy is stabilised        Hanger  Bracket    Down Rod          1  Do not attempt to operate the fan  or optional light kit  with any wall control that is not  approved by Hunter Pacific for use with its fans  DO NOT use solid state controllers  The  use of unapproved controllers will void your warranty       2  Do not mix blade sets from one fan to another as this may upset the balance of the fan  If  WARNING only one blade is damaged you are still required to replace with a new set        5    HUNTER PACIFIC    INTERNATIONAL    Assembling the fan       STEP 7  Fig  8   a  Once all blades are attached to the motor  housing  refit the base  The tabs should lock in to  place ensuring the base plate is sec
11. ll control that is not  approved by Hunter Pacific for use with its fans  DO NOT use solid state controllers  The  use of unapproved controllers will void your warranty       2  Do not mix blade sets from one fan to another as this may upset the balance of the fan  If  WARNING only one blade is damaged you are still required to replace with a new set        10    HUNTER PACIFIC Electrician Installation Manual    Icon Ceiling Fan    INTERNATIONAL    Trouble Shooting Tips     Fan    Fan will not start    Check that the reversing switch is pushed into its Summer or Winter position   Check wire connections in the wall switch and terminal blocks  ensure all wires  are making proper contact    If it is a Typhoon fan  check and ensure the reversing switch plate under the  switch cover is not bent  also check the 3 wires coming from the switch plate are  straight  Occasionally the switch plate may get bent during transportation  this  allows the switch cover to press against the plate and stop the fan from working   If it is a Typhoon fan  check the nine pin plug under the switch cover is properly  connected and the colours on the plug are corresponding    If it is a concept fan and it has an external start up capacitor  check that this  external capacitor is properly connected     Fan speed is not corresponding to the wall controller    Check the speeds on the wall controller has been wired correctly and are making  proper contact  Brown   speed 1  Purple  speed 2  Red   speed 3    
12. ted if products have been installed by unlicensed persons     3  Damage caused by incorrect installation  force majeure  electrical surges  lightning  power grid  fluctuations  water or by connection to alternative power supply sources  such as solar inverters   etc   is not eligible for warranty repair     4  Blades must be replaced only as a complete set  Blades are supplied only as a pre balanced set  and the replacement of individual blades may void the warranty by causing mechanical  damage to the motor  excessive noise or premature wear     5  When products are installed in a location requiring special access equipment  Such as    scaffolding or scissor lifts  etc  the cost of providing  installing and operating special access  equipment must be borne by the site owner     For safety  and to protect your customers warranty  the following must be taken into  account when installing and operating the product  s       a  DO NOT USE SOLID STATE WALL CONTROLLERS  Neither leading nor lagging edge  controllers will give satisfactory performance  Wall controls must only be types approved  for use by Hunter Pacific International    The fan  light and bracket must be earthed   Fan and light must be run from the same final circuit   Mounting bracket must be firmly screwed to a solid structure such as a concrete ceiling     steel structure or timber framing  If additional bracing is added it must be firmly secured to  the rafters and not left floating on the ceiling  Special mounts
13. this may upset the balance of the fan  If  only one blade is damaged you are still required to replace with a new set     11    HUNTER PACIFIC Electrician Installation Manual    Icon Ceiling Fan    INTERNATIONAL    WARNING       Trouble Shooting Tips     Light    Light will not turn on   Make sure globe has not blown and it is properly fit   ted between the metal prongs  Check all light wires in the light kit  the terminal  block in the canopy cover and the wall switch have been connected together  correctly     Light is not corresponding to remote control  Make sure globe has not  blown and it is properly fitted between the metal prongs  Check all light wires  in the light kit  the terminal block in the canopy cover and the wall switch have  been connected together correctly  Check dip switch settings in remote hand  piece and remote receiver correspond     Light wires appear to be missing or too short   Wires may be stuck in the  motor housing  Carefully pull wires out of the motor housing  careful not to  strip the wires as this may cause the fan to short     Light flickers or flashes   Check globe is secured between the metal prongs  in the light kit  Make sure you are using the globes specified     National Warranty Line 1300 360 280    Monday to Friday from 9am to 5pm EST  Only available within Australia    1  Do not attempt to operate the fan  or optional light kit  with any wall control that is not  approved by Hunter Pacific for use with its fans  DO NOT use solid st
14. urely    attached to the motor housing        WARNING       Reverse _       Electrician Installation Manual  Icon Ceiling Fan    STEP 6  Fig 7   a  Slightly push the base plate upward and turn  anticlockwise until tabs unlock to remove it    b  Once the base plate is removed  the   internal blade carriers will be exposed  Insert blades  and attach them to the motor housing as shown in  figure 8    c  Tighten the 3 blade screws firmly but do not over  tighten    d  Install blades for each fan individually              Base Plate    STEP 8  Fig  9   a  Reverse switch should be in the down  position for Summer  fan spins anticlockwise   and in the up position for Winter  fan spins  clockwise     b  Make the sure reverse switch is not stuck in  its neutral position otherwise the fan will not  spin     Do not attempt to operate the fan  or optional light kit  with any wall control that is not  approved by Hunter Pacific for use with its fans  DO NOT use solid state controllers  The  use of unapproved controllers will void your warranty     Do not mix blade sets from one fan to another as this may upset the balance of the fan  If  only one blade is damaged you are still required to replace with a new set     6    HUNTER PACIFIC Electrician Installation Manual    Icon Ceiling Fan    INTERNATIONAL    Attaching an accessory light kits   78 mm halogen light  MAX 100W    WARNING       SN J       STEP 1  Fig  10  a  Slightly push the base plate upward and turn  until tabs unlock to remov
    