NESS Medi-Alarm Installation Manual
Contents
1. 5 1 WRIST WATCH The wrist watch is water proof The wrist watch model is attached to the wearer s wrist by a strap It may be worn either left or right handed It has 1 HELP button on the face Doc ID 100 106 PROGRAM MANUAL DOC 5 6 PROGRAM SUMMARY Option Default Transmitter 1 Program Transmitter 2 Program Transmitter 3 Program Transmitter 4 Program Transmitter 5 Program Transmitter 6 Program Transmitter 7 Program Transmitter 8 Program System Check Dial Type Aus NZ Primary Phone Number Secondary Phone Number Client Account Number Over Due Timer Enable Inactivity Timer Test Call Timing Time to First Test Call Restores Enabled Button Operation Quiet Operation Programming Via modem Exit Program Mode Doc ID 100 106 PROGRAM MANUAL DOC 6 1 PROGRAM MODE To enter PROGRAM mode turn the Medi Alarm off by unplugging the mains plug and removing the 9 volt battery Turn the Medi Alarm on by replacing the 9 volt battery The Medi Alarm will display the version number for 0 5 seconds followed by 1 indicating that PENDANT may be programmed Within 5 seconds of connecting the battery press the CANCEL button on the Medi Alarm to enter program mode The speaker will beep and the display will show 2 on the display or If a pendant is to be programmed as pendant 1 press any button 3 times on an unprogrammed pendant to program The pendant must not have been previously programmed The spea
2. Up to 14 digits may be programmed Pause 0 9 Digits 0 9 t Star H Hash 8 Press the CANCEL button N will be displayed steady eg To program the number 762308 follow these steps 1 Press the HELP button then the CANCEL button to view the current phone number after which N will flash 2 Press the HELP button until 7 is displayed press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store the number The next digit will flash 3 Press the HELP button until 6 is displayed press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store the number The next digit will flash 4 Press the HELP button until 2 is displayed press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store the number The next digit will flash 5 Press the HELP button until 3 is displayed press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store the number The next digit will flash 6 Press the HELP button until 0 is displayed press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store the number The next digit will flash 7 Press the HELP button until 8 is displayed press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneousl
3. battery 1 x Showerproof transmitter pendant with battery 1 x Connection lead for T200 Series telephone 1 x Owners Manual Optional Mode 5 Adaptor lead Doc ID 100 106 PROGRAM MANUAL DOC 3 3 Installation The Ness Medi is extremely easy to install and requires no tools The normal location for the Medi Alarm is at the first telephone installed in the premises This ensures that the Medi Alarm has priority if it needs to send a message to the central monitoring station The local telephone sits on top of the Medi Alarm unit to make it as unobtrusive as possible Another important aspect of the installation is the location of the Medi Alarm unit to give optimum radio coverage To give the best all round coverage it is best to have the Medi Alarm installed centrally in the premises This may not always be possible due to the location of the telephone and mains power but it must still be a consideration Once a suitable location is found the install can take place INSTALLATION EXAMPLE This example is based on the common Telstra T200 series telephone 1 Select the best location taking into consideration the customers requirements and the above criteria 2 Connect the plug pack and 9 volt Lithium battery and enter program mode if necessary by pressing the CANCEL within five seconds of powering up the system See programming guide 3 Program in any additional pendants and or detection devices and other program parameters as r
4. will cause an alarm In doubtful environments remove the link 3 to 4 pulses will cause an alarm 6 3 1 Radio Reed Switch The Ness radio reed switch is a multipurpose radio device It has an internal reed switch and has the provision for an external reed switch It can also function as a radio vibration analyser if a Nessensor VIB100 is connected to the external device input A 9 volt lithium battery powers the reed switch and should last approximately 3 years 25 activation s per day Terminals and Link Settings Two way terminal block TB1 The terminal block is used to connect a normally closed reed switch or a Nessensor VIB100 The cable length to the external switch should be kept to a minimum and no longer than 40 cm I B E Pins Link in I B position Only the internal reed switch controls the transmitter External devices are disabled Link REMOVED Both the internal reed switch and the external device are connected in series with the transmitter Link in E B position Only the External device controls the transmitter The internal reed switch is disabled Program link Program mode should only be needed if a new 16 bit code random or fixed needs to be entered See the setup testing section on page to program a fixed code into a reed switch 1 0 R Pins These pins are used to either program a fixed code multiple devices with the same code or to generate a random code Radio Enable l
5. will flash A If you wish to view the programmed number again press the HELP button then the CANCEL button to display the number 9 Press the CANCEL button to display A steady Note All four digits must be programmed Press the Cancel button to move to the next program option Doc ID 100 106 PROGRAM MANUAL DOC 11 0 ENABLE OVER DUE TIMER The Over Due Timer is the time period between CANCEL button presses to restart the over due timer The over due timer is for local indication purposes only no alarm report is sent 0 255 hours default 0 disabled 1 2 or 3 digits may be programmed with a maximum of 255 hours If a number greater than 255 is programmed Medi Alarm will sound a long beep and re display the original value 1 is steady on the display 2 Press the HELP button and the programmed time will be flashed out in hours The display will flash o 3 Press the HELP button until the first digit is on the display to 9 4 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 5 Press the HELP button until the second digit is on the display 0 to 9 6 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 7 Press the HELP button until the third digit is on the display to 9 8 Pr
6. ELP and CANCEL buttons simultaneously to store each digit _ will flash 7 Press the HELP button until the third digit is on the display 0 to 9 8 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 9 Press the CANCEL to view the programmed time t will flash on the display To view the programmed time again press the HELP button then the CANCEL button and the stored value will flash on the display after which t will flash 10 Press the CANCEL button to display t steady Press the Cancel button to move to the next program option F TIME TO FIRST TEST CALL The time till first call should be programmed so that the first test call will be made during a low activity period of the monitoring station eg midnight 1 2 or 3 digits may be programmed with a maximum of 255 hours If a number greater than 255 is programmed Medi Alarm will sound a long beep and re display the original value 1 F is on the display 2 Press the HELP button and the programmed time will be flashed out in hours The display will flash F 3 Press the HELP button until the first digit is on the display 0 to 9 4 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 5 Press the HELP button until the second di
7. ID 100 106 PROGRAM MANUAL DOC 20
8. L All test calls are then made at intervals specified by program option TEST CALL TIME TIME TO FIRST TEST CALL option should be programmed The dialler reports alarms to a central monitoring station in Ademco High Speed format New alarms initiate a dial out report Alarms are deemed to be restored when the CANCEL button on the Medi Alarm is pressed Doc ID 100 106 PROGRAM MANUAL DOC 17 7 2 1 Alarm Reporting States Each alarm may be reported as one of the following states e New alarm e Normal e Outstanding Restore 7 2 2 Alarms Reported The following alarms may be sent on the dialler Help pendant or main unit Call Alarm Inactivity Alarm A C fail Low battery Medi Alarm Low battery pendant Test calls 7 3 ADEMCO HIGH SPEED EXTENDED REPORTING This reporting is used to transmit alarms from a subscriber s site to a central monitoring station via the telephone The transmission is done using DTMF tones 14 digits are sent to report an alarm The format is as follows 5555 QQQQQQQQ TE SSSS 4 digit subscriber ID Q Event qualifier 8 Channels Channels 1 8 indicate the status of the 8 reporting channels Each channel may have the following values 1 New alarm 3 Restore 5 Normal 6 Previously reported event T Channel 9 indicates the type of event Channel 9 may have the following values 1 Extra Alarms 5 Zone Trouble 6 System Alarms 7 Zone Alarm 9 Test Ther
9. NESS SECURITY PRODUCTS MEDI ALARM INSTALLATION MANUAL D Barker 18 5 01 Doc ID 100 106 PROGRAM MANUAL DOC TABLE OF CONTENTS Introduction Packaging Installation Wiring Inputs Outputs Program Summary Program Mode Program Options Peripheral Devices Radio PIR Radio Reed Switch Dialler Alarm reporting Specifications Doc ID 100 106 PROGRAM MANUAL DOC 1 Introduction Ness Security Products have developed the Ness Medi Alarm which provides the sick or elderly Mum Dad friend or patient a simple and instant means of summoning assistance when needed And nothing could be easier to use than the feature packed Medi Alarm It s like having a full time carer that never sleeps Simply by pressing a radio pendant that can be worn around the neck as a wrist watch or on a key ring assistance can be summoned within seconds These seconds could make all the difference If the transmitter is activated a radio signal is sent to the main unit The Medi Alarm will then dial one or two pre programmed telephone numbers and send an alarm message to central monitoring station indicating that HELP is required The Ness Medi Alarm is easy to install and very simple to use It is designed to comply with the Australian Standard AS2999 for such devices 2 Packaging The Ness Medi Alarm comes complete with the following items 1 x Medi Alarm Main unit 1 x Plug Pack for Mains connection 1 x 9 volt Lithium long life
10. atus display or 1 Press the HELP button to step through the values 0 or 1 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to program the value Australia 1 New Zealand Press the Cancel button to move to the next program option Doc ID 100 106 PROGRAM MANUAL DOC 9 N PRIMARY PHONE NUMBER default The primary telephone number is the first number that the dialler calls when an event message needs to be sent 1 N is on the display 2 Press the HELP button to view programmed phone number The programmed phone number will be flashed on status display N will flash after the phone number is flashed out on the display If you wish to view the phone number again press the HELP button then the CANCEL button to display the phone number 3 To program a phone number press the HELP button to step through the digits 1 2 3 4 5 6 7 8 9 0 t H and 4 Press the SIDE LEVER button to store each digit The display will show the next digit to be programmed 5 Press the HELP button until the next digit is on the display 6 Press the SIDE LEVEL button or press the HELP and CANCEL buttons simultaneously to store each digit Continue this method until all the numbers are programmed 7 Press the CANCEL button to display the programmed number N will flash on the display after the number is displayed
11. efore channel 9 determine what channels 1 8 mean E Error check Doc ID 100 106 PROGRAM MANUAL DOC 18 Alarms sent without CALL button option ETE ee a eee ees Alarms sent with button option b is selected for CALL c option 5 ae a eee ee eee HELP Doc ID 100 106 PROGRAM MANUAL DOC 19 Medi Alarm Specifications Plug Pack 17 20 volts AC 300 mA Medi Alarm Main Unit Back up Battery Average Quiescent Current Low Voltage Warning Radio RX Frequency Radio Pendant Operating Voltage Low Voltage P display Quiescent Current Carrier Frequency RF Power Output Battery Type Radio PIR Detector Battery Low Voltage AL display Quiescent Current Type No of Zones inc creep Sensitivity Control Range Control RF Radio Reed Switch Battery Low Voltage Quiescent Current Transmit Current R F 9 volt Lithium Approx mA 7 5 volts Dynamic 303 875 MHz 8 to 12 Volts 10 5 volts OuA 303 875 MHz 10 uW PEP 12 Volt Alkaline Vinnic L1028 Duracell MN21 Energiser A23 9 Volt Lithium Ultralife 7 5 volts Less than 30uA Passive Infra red Dual element 21 1 2 or 3 4 Pulses High 14M Low 8M as per Radio Pendant specs 9 Volt Lithium Ultralife 7 5 Volts 4uA 10 to 14 mA as per Radio Pendant specs This document is accurate at the time of print however this is subject to specification being revised at any time Doc
12. equired 4 After which conduct a signal strength check on all devices to ensure correct radio operation 5 Unplug the modular telephone plug on the T200 phone marked as LINE and plug it into the modular telephone socket marked Line In on the Medi Alarm 6 Using the supplied jumper lead with a modular telephone plug on each end Plug one end into the socket on the Medi Alarm marked Line Out and the other end into the T200 phone marked LINE 7 Lift the handset on the telephone to check that dial tone is present This completes the telephone wiring process 8 If the Medi Alarm is in program mode and no further programming is required press the CANCEL button until E is on the display then press the HELP button to leave program mode NOTE It may be worth while to pre program the system prior to arriving at the customers premises to ensure a smooth install takes place Doc ID 100 106 PROGRAM MANUAL DOC 4 4 FRONT PANEL INDICATORS Colour code AS2999 RED help YELLOW fault GREEN cancel WHITE reassurance MAINS CANCEL BATTERY RED HELP LIGHT amp BUTTON GREEN CANCEL LIGHT amp BUTTON Yellow 7 segment display used for PROGRAM mode and FAULT indication Green MAINS FAIL steady normal flashing mains fail Yellow LOW BATTERY off normal flashing low battery FAULT off normal flashing fault 5 PERSONAL RADIO TRANSMITTERS
13. ess the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 9 Press the CANCEL to view the programmed time will then flash on the display To view the programmed time again press the HELP button then the CANCEL button and the stored value will flash on the display after which o will flash 10 Press the CANCEL button to display o steady Press the Cancel button to move to the next program option i INACTIVITY TIME The inactivity timer alarm is triggered if the CANCEL button or detector is not triggered in this time 1 255 hours default 0 1 2 or 3 digits may be programmed with a maximum of 255 hours If a number greater than 255 is programmed Medi Alarm will sound a long beep and re display the original value 1 T is on the display 2 Press the HELP button and the programmed time will be flashed out in hours The display will flash i 3 Press the HELP button until the first digit is on the display to 9 4 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 5 Press the HELP button until the second digit is on the display 0 to 9 6 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 7 Press the HELP b
14. etermines the manner in which the radio pendant buttons operate the system default H 1 b is on the display steady 2 Press the HELP button to view the programmed value H Help C Cancel c call 3 Press the HELP button to select a value 4 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store the selected value H All buttons generate a HELP alarm Additional buttons generate a CANCEL to restore HELP alarms bottom button Buttons generate CALL HELP and CANCEL Diagram below describes the button operation for this option HELP SIDE LEVER Press the Cancel button to move to the next program option q QUIET OPERATION Determines if the internal beeper operates during alarm operation Default 0 is on the display Press the HELP button to view the programmed value Programmed dial type will be flashed on status display 0 or 1 Press the HELP button to step through the values 0 or 1 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to program the value Beeps activated 1 Quiet operation Doc ID 100 106 PROGRAM MANUAL DOC 14 Press the Cancel button to move to the next program option p PROGRAMMING VIA MODEM The Medi Alarm may be remotely programmed via a telephone modem link Remote programming is enabled in pr
15. git is on the display 0 to 9 6 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 7 Press the HELP button until the third digit is on the display 0 to 9 8 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 9 Press the CANCEL to view the programmed time F will flash on the display To view the programmed time again press the HELP button then the CANCEL button and the stored value will flash on the display after which F will flash 10 Press the CANCEL button to display F steady Press the Cancel button to move to the next program option Doc ID 100 106 PROGRAM MANUAL DOC 13 RESTORES ENABLED This option selects whether restore reports are sent to the central station if the alarm restores or the CANCEL button is pressed default r 1 is on the display steady 2 Press the HELP button to view the programmed value r restore reports no restores 3 Press the HELP button to select a value 4 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store the selected value Norestores sent by dialler Restores enabled Press the Cancel button to move to the next program option b BUTTON OPERATION This option d
16. he next program option SYSTEM CHECK Check radio signal strength of pendants and detectors Displays the first pendant or detector s signal strength 1 being minimum and 9 being maximum Only one pendant or detector can be tested at a time The signal level is displayed and also beeped to indicate the level Doc ID 100 106 PROGRAM MANUAL DOC 8 To test the signal strength of a Pendant 1 C is on the display 2 Press the Help button for the Medi Alarm to accept a signal 15 displayed 3 Press the SIDE LEVER to check signal strength of transmitter 2 No pendant received 1 9 Signal strength of pendant Press the Help button for the Medi Alarm to accept another signal is displayed To test the signal strength of a Radio PIR or Reed Switch 1 C is on the display 2 Press the Help button for the Medi Alarm to accept a signal is displayed 3 Activate the detector in normal operation location Display will show the signal strength of the detector triggered 2 No pendant received 1 9 Signal strength of pendant Press the Help button for the Medi Alarm to accept another signal is displayed Press the Cancel button to move to the next program option d DIAL TYPE Determines the dialling type Australian or NZ Default 0 Australia is on the display Press the HELP button to view the programmed value Programmed dial type will be flashed on st
17. ink Having the link ON will allow the radio transmitter to operate Taking the link OFF will disable the transmitter could be handy when programming multiple detectors into the main unit The LED will indicate Doc ID 100 106 PROGRAM MANUAL DOC 16 detection with the link ON OFF Always remember to have the link on so it can communicate with the Securityguard Tamper Button When the plastic housing is lifted a tamper alarm message is sent A low level warning will sound in disarm or home mode A full alarm will sound if in armed state Sensitivity Control VR1 The sensitivity control is used to adjust the sensitivity of the vibration sensor Nessensor This control Low full anti clock wise High full clock wise can be used in conjunction with the sensitivity settings on the Nessensor itself High Medium Low If a vibration sensor is not used have the sensitivity set to low full anti clock wise Important Care should be taken when handling the circuit board as the reed switch is quite fragile Incorrect handling may damage the vacuum seal of the reed and cause short and long term intermittent operation 7 DIALLER The dialler will report alarms to a monitoring center and is also capable of remotely programming the Medi Alarm via a modem link 7 1 REMOTE PROGRAMMING The Medi Alarm may be remotely programmed via a telephone modem link Remote programming is enabled when in Medi Alarm is in
18. ker will beep with each button press and beep twice on the third button press and the status display will show P Press the CANCEL button and the display will show 2 or If the HELP button on the Medi Alarm is pressed the speaker will beep once and the display will show the status of Transmitter 1 generally a pendant where unprogrammed and Programmed or If no buttons are pressed within 5 seconds and Medi Alarm is programmed the Medi Alarm will return to operation mode 6 2 PROGRAMMING RULES Program options are displayed steady the values for each option flash Press the CANCEL button on the Medi Alarm to step through the options 1 2 3 4 5 etc Press the HELP button to view the programmed value for that option The values will be displayed flashing To step through values press the HELP button To store a program change press the HELP and CANCEL buttons simultaneously on the Medi Alarm unit Press the CANCEL button to step to the next option Colour code AS2999 CANCEL RED help mains YELLOW fault GREEN cancel Doc ID 100 106 PROGRAM MANUAL DOC 7 6 3 PROGRAMMING OPTIONS Option Description 1 AANIAM EWN TRANSMITTER 1 PROGRAM 1 1 is on the display 2 Press the HELP button to view programmed option unprogrammed no device has been programmed for transmitter program
19. med pendant a device is programmed for transmitter 1 E erase remove previously programmed device To program a new pendant e Display must show unprogrammed e Press any button on a new unprogrammed pendant 3 times Medi Alarm will Beep with each press and twice on the third press to acknowledge when the key is programmed The display will show P to indicate that the pendant is programmed To program a new detector e Display must display unprogrammed e Trigger detector 3 transmissions must be detected Medi Alarm will Beep with each transmission of the detector and twice on the third transmission to acknowledge when the detector is programmed The display will show P to indicate that the detector is programmed Erasing Pendants or Detectors Go to the Transmitter option you wish to erase 1 to 8 To erase a user pendant or detector press HELP to select E ERASE not available if unprogrammed e Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to erase Display will show indicating erased Press the Cancel button to move to the next program option TRANSMITTER 2 PROGRAM TRANSMITTER 3 PROGRAM TRANSMITTER 4 PROGRAM All pendants and detectors are programmed in TRANSMITTER 5 PROGRAM the same manner as Transmitter 1 TRANSMITTER 6 PROGRAM TRANSMITTER 7 PROGRAM TRANSMITTER 8 PROGRAM Press the Cancel button to move to t
20. ogram mode or may be enabled in normal operation mode by setting the program option default 0 enabled in program mode only NOTE Answer type is Fax Defeat regardless of option 1 P is on the display steady 2 Press the HELP button to view the programmed value 0 Program mode always enabled 3 Press the HELP button to select a value 4 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store the selected value 0 Enabled only in program mode 1 Enabled all the time Press the Cancel button to move to the next program option E Exit Program Mode Press HELP to exit program mode or press the CANCEL button to go to option 1 Peripheral Devices Radio PIR The radio PIR is based on the Ness Quantum Ten design It uses a 9 volt lithium battery as its power source with it s 4 minute sleep time the battery life should be slightly longer The PIR uses the Heimann Pyro Electric sensor for reliable stability The PIR has very strong terminals mounted directly to the circuit board Link settings Radio Enable link Having the link ON will allow the radio transmitter to operate Taking the link OFF will disable the transmitter could be handy when programming multiple detectors into the main unit The LED will indicate detection with the link ON or OFF Always remember to have the link on so it can communicate
21. program mode and may be enabled in NORMAL mode by setting the program option Medi Alarm may be installed in parallel with answering machines faxes etc which will all answer the phone Medi Alarm uses an answering technique called fax defeat Fax defeat is done by calling the panel hanging up and calling back The panel will answer the phone as soon as the call back ring is detected All program options may be remotely programmed Medi Alarm will remain on line for 4 minutes while communicating with modem This ensures communication failures will not leave Medi Alarm in program mode 7 2 ALARM REPORTING This reporting is used to transmit alarms from a subscriber s site to monitoring center via the telephone There are 2 phone numbers a primary number N and a secondary number n Reports are usually sent on the primary number but if the dialler is unsuccessful in connecting it will dial the secondary number Telephone numbers N and n must be programmed into the Medi Alarm s memory A client account number is allocated by the monitoring company to identify the customer The client account number must be programmed into the Medi Alarm s memory Time till first test call option allows test calls to be sent to monitoring during non peak periods usually at night This time is only used when exiting program mode The first test call is made in the time specified by program option TIME TO FIRST TEST CAL
22. utton to display the programmed number n will be flash after the number is displayed Up to 14 digits may be programmed Pause 0 9 Digits 0 9 t Star H Hash 8 Press the CANCEL button n will be displayed steady Note See example of telephone number 1 for more details Press the Cancel button to move to the next program option A CLIENT ACCOUNT NUMBER The client account number identifies to the central station which Medi Alarm is sending the alarm message Default 0000 1 A is steady on the display 2 Press the HELP button to view the programmed client account number The programmed client account number will be flashed on display 0 9 after which the display will flash A 3 Press the HELP button until the first digit of the client account number is displayed 4 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit The display will show the next digit to be programmed 5 Press the HELP button until the second digit of the client account number is displayed 6 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit The display will show the next digit to be programmed 7 Continue this method until all 4 digits are programmed 8 After the forth digit is stored the display will show the programmed client account number after which the display
23. utton until the third digit is on the display to 9 8 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 9 Press the CANCEL to view the programmed time i will then flash on the display To view the programmed time again press the HELP button then the CANCEL button and the stored value will flash on the display after which i will flash 10 Press the CANCEL button to display i steady Press the Cancel button to move to the next program option Doc ID 100 106 PROGRAM MANUAL DOC 12 t TEST CALL TIME This option controls to time between the automatic test calls the Medi Alarm will make 1 2 or 3 digits may be programmed with a maximum of 255 hours If a number greater than 255 is programmed Medi Alarm will sound a long beep and re display the original value 0 255 hours default 24 hours 0 Disabled 1 is on the display 2 Press the HELP button and the programmed time will be flashed out in hours The display will flash t 3 Press the HELP button until the first digit is on the display 0 to 9 4 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit _ will flash 5 Press the HELP button until the second digit is on the display 0 to 9 6 Press the SIDE LEVER button or press the H
24. with the Medi Alarm Test link In Test mode the three minute sleep time is disabled Test mode is used to check PIR detection coverage The LED will come on every time the PIR is triggered Normal link This link setting is the standard setting for normal operation This setting gives the PIR maximum battery life as it activates the four minute sleep time Program link Program mode should only be needed if a new 16 bit code random or fixed needs to be entered 1 0 R Pins Doc ID 100 106 PROGRAM MANUAL DOC 15 These pins are used to either program a fixed code multiple devices with the same code or to generate random code Range link The range link is a means of setting the level of Infra red energy required to generate a pulse from the detector this in turn directly affects the range of the detector The correct setting will depend on the size of the area to cover With the range link ON the detector will detect to the full 12m x 12m With the range link removed the detector will detect to approximately 8m x 8m The range link should always be set to the lowest setting which will still provide good coverage Pulse Count link At times it may be unavoidable to install the detector in a difficult environment Pulse count is a means of adjusting the number of pulses received therefore the number of steps before an alarm is generated In a normal stable environment the link should be ON to 2 pulses
25. y to store the number The next digit will flash 8 Press the CANCEL button to view the programmed number after which N will flash 9 Press the CANCEL button N will be displayed steady Press the Cancel button to move to the next program option n SECONDARY PHONE NUMBER default The secondary telephone number is the second number that is called when an event message needs to be sent The secondary number is used if the primary number is unsuccessful 1 n is on the display Doc ID 100 106 PROGRAM MANUAL DOC 10 2 Press the HELP button to view programmed phone number Programmed phone number will be flashed on the display n will flash after the phone number is flashed out on the display If you wish to view the phone number again press the HELP button then the CANCEL button to display the phone number 3 To program a phone number press the HELP button to step through digits 1 2 3 4 5 6 7 8 9 0 t H and 4 Press the SIDE LEVER button or press the HELP and CANCEL buttons simultaneously to store each digit The display will show the next digit to be programmed 5 Press the HELP button until the next digit is on the display 6 Press the SIDE LEVEL button or press the HELP and CANCEL buttons simultaneously to store each digit Continue this method until all the numbers are programmed 7 Press the CANCEL b
Download Pdf Manuals
Related Search
Related Contents
Université de Sherbrooke LA STRATÉGIE AUTOFICTIONNELLE DE Tascam MP-VT1 MP3 Player User Manual Bedienungsanleitung MAC100 Manual Whirlpool EH180FXL User's Manual Guía práctica de “Handycam” NEX-VG20/VG20H MAGNIA R3320b Chapter 5-Electronics - antares ECF15 RC-18 RC-24 RC-30 RC secadora de roupa à gás secadora de roupa à gás Copyright © All rights reserved.