Home
National Warranty Line Installation Manual
Contents
1. Electricians make sure everything on this checklist is ticked off before you leave the installation site If you have trouble installing our product please refer to the trouble shooting section on the previous page first then phone the Hunter Pacific Warranty Line on 1300 360 280 open 9am to 5pm EST DO NOT uninstall the fan and DO NOT return fan to retailer without calling the support line first Ceiling fan _is not installed to a solid state wall controller Neither leading nor 1 lagging edge controllers will give satisfactory performance Wall controllers must only be types approved for use by Hunter Pacific International 2 The fan fan light if fitted and bracket is earthed 3 Fan and optional fan light are run from the same final circuit Mounting bracket must be firmly secured to a solid structure such as a concrete ceiling steel structure or timber framing If additional bracing is added it must be i firmly secured to the rafters and not left floating on the ceiling Special mounts such as T hooks are available for certain types of installation 5 Fan blades are at least 2 1m 7 feet above floor level 6 Check the fan is operating correctly on all three speeds using the pull cord or wall controller T If light is installed Check light is working and light switch is functioning properly If remote control is installed Check the fan and light if installed is responding to n the remote control 9 A separat
2. Installation Manual Installation Instructions Assembling the fan NOTE If installing an Accessory Light refer to the light installation instructions enclosed in the light kit STEP 5 Fig 5 a Loosen canopy screws half way b Slide canopy cover up and over the hanger bracket and position canopy screws through the keyway in canopy cover c Rotate the canopy clockwise and tighten screws until canopy cover is tightly held d Check rim of canopy is not touching the ceiling Add packing washers between canopy and bracket to lower canopy Top Canopy Canopy Screw Attaching the blades Metal If attaching Timber blades please turn to page 8 s a Attach blades to the motor housing using ae the 2 screws provided Tighten the Blade a oN m Holder Screws firmly Do not use power tools Blade Holder STEP 6 Fig 6 EB Screw 1 gt gt t a b Repeat this step for all four blades Install a f each blade individually Do not mix blades J J from different fans as this can upset the M i balance of the fan otor Housing STEP 7 Fig 7 a Check to ensure the reverse switch is locked into position Make sure it is either set in the Summer or Winter position b Test and ensure fan is operating correctly on all three speeds in both forward and reverse Reversing Switch 1 Do not attempt to operate the fan or optional light kit with any wall control that is not approved by
3. d D Typh i HUNTER PACIFIC YP mache I N TERN ATI ON AL Installation Manual Typhoon Typhoon 316 MACH mach mach Note Picture is of Typhoon Mach 2 Metal and is for illustrative purposes only CEILING FAN MUST BE INSTALLED BY A LICENSED ELECTRICIAN NO OTHER PERSONS SHOULD ATTEMPT TO INSTALL THIS FAN Electricians are recommended to tick off all items on the quick checklist and fill out their details onto the back page of the Fan Owner Warranty amp Operations Manual after installation ELECTRICIANS TO PROTECT YOUR CUSTOMER S WARRANTY PLEASE READ PAGE 2 OF THIS BOOKLET PRIOR TO THE INSTALLATION OF THIS PRODUCT National Warranty Line 1300 360 280 Monday to Friday from 9am to 5pm EST Only available within Australia Hunter Pacific International Pty Ltd Building 8 256 New Line Road Dural NSW 2158 Australia ABN 18 063 521 666 IMPORTANT INFORMATION EVERYONE MUST READ PRIOR TO INSTALLATION 1 Distributor and installer details and purchase receipts are essential for on site warranty claims and must be presented to repair personnel make sure you record your details in the Fan Owner Warranty and Operations Manual 2 Fans and fixed wiring products must only be installed by persons who are appropriately licensed by the applicable State regulatory body Therefore to protect our repair personnel on site warranty claims will not be accepted if products have been installed by unlicensed persons
4. 3 Damage caused by incorrect installation force majeure electrical surges lightning power grid fluctuations water or by connection to alternative power supply sources such as solar inverters etc is not eligible for warranty repair 4 When products are installed in a location requiring special access equipment such as scaffolding or scissor lifts etc the cost of providing installing and operating special access equipment must be borne by the site owner for all service or warranty work 5 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance AS NZS 60335 1 C1 7 12 DANGER Contact with ceiling fan blades can cause serious injury or death To electricians and installers The Australian Competition and Consumer Law 2010 mandates consumer protection against defects or poor workmanship in provision of services Such as installing a ceiling fan To protect yourself and the consumer these instructions must be followed Failure to do so may result in the consumer making a claim against you for consequential loss or damage 6 A double pole isolation switch providing full disconnection of both fan and light must be fit
5. a light fitting is going to be used Cap seal light wires if a light fitting is not going to be used NOTE Terminal Block shown on bracket may not be supplied with all models 1 Do not attempt to operate the fan or optional light kit with any wall control that is not approved by Hunter Pacific International for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set Installation Manual Installation Instructions Assembling the fan Wiring Instructions with and without accessory light WARNING To comply with AS NZS 60335 1 a Double Pole Isolation switch must be fitted in series with the supply of this product an RCD may fulfill this function if suitably labeled Fig 4 Isolation Switch Live m n Neutral a Earth Fan R Light Control Switch 1 Do not attempt to operate the fan or optional light kit with any wall control that is not approved by Hunter Pacific International for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set 6
6. Hunter Pacific International for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set 7 Installation Manual Installation Instructions Assembling the fan Attaching the blades Timber STEP 6 Fig 8 a 4 a Place Blade onto Blade Holder Washer_____ Z b Insert Blade Screw through Blade Holder Blade by ie a and Blade a c Place washer over Blade screw and thread nut onto Blade Screw Now tighten the Blade Screws firmly Do_not use power tools Repeat this step for all four blades Install each blade individually Do not mix blades from different fans as this can upset the balance of the fan Blade Holder g STEP 7 Fig 9 a Attach blades with blade holders to the motor housing using the 2 screws provided Do not use power tools b Repeat this procedure for the other 3 blades Housing STEP 8 Fig 10 a Check to ensure the reverse switch is locked into position Make sure it is either set in the Summer or Winter position b Test and ensure fan is operating correctly on all three speeds in both forward and reverse j Reverse Switch 1 Do not attempt to operate the fan or optional light kit with any wall control that is not approved by Hunter Pacific Internation
7. a e E wis i Eas o n fe fos CO Top canopy serons 2 aopyCovr 1 HPIWatConoier 1 e ey E nomon es Installation Manual Parts List Tyohoon Mach 2 Timber Hanger Bracket ___ Top Screws ee Blade Nut Ball Hex Head Joint Blade Washer Top Sa Canopy Canopy Cover Motor Housing Blade Holder 8 Blade Screw Holder Screw Base Plate ee a O ea e Jox eadswrew oonnRoaPn 1 BaceHogersaons 6 Tepcarepy oom roa srotsoew 2 anae serous T16 Installation Manual Installation Instructions Assembling the fan NOTE If an extension down rod needs to be installed please go to page 9 Hanger Bracket Red White Earth Wires STEP 1 Fig 1 a Drill a hole in the timber nogging for wiring b Secure the hanger bracket onto the timber nogging using the two hex head screws provided The timber nogging should be supplied by the installing electrician and must be supported between the two ceiling joists as shown in the diagram STEP 2 Fig 2 a Hang the ball joint into the hanger bracket Ensure the groove on the hanger bracket is locked into the slot on the ball joint This is important to ensure the fan will not wobble and the weight of the fan is supported STEP 3 Fig 3 a Connect wires from the fan with wires in the ceiling b Make sure earth wires are also connected c Connect light wires red white if
8. al for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set 8 Installation Manual Installation of an Extension Down Rod NOTE Hunter Pacific International Down Rods to be used ONLY Ball Joint Canopy Cover ae Down Rod Connection Collar Ra Cotter Pin c ae lt lt va Rod Pin es o Step 1 Fig 11 a Loosen screws holding the Canopy Cover and Ball Joint b Loosen the down rod screws and unlock the cotter pin to remove the standard down rod from the motor housing c Remove Ball Joint Pin and slide off Ball Joint Top Canopy and Canopy Cover Cover Screw ee Down Rod o Collar Pi X Spee in Motor ___ ww Ve Z RY Down Rod Pin Housing Extension Neb se gt Down ae o Step 2 Fig 12 a Now install the extension rod in reverse order of Step 1 to secure the extension down rod to the fan b Tighten Canopy Cover screws to Down Rod to prevent it from rattling Do_not use power tools NOTE If the extension rod needs to be shortened cut the rod to the required length and drill the appro priate hole size to fit the ball joint pin The cut end of the rod should be used on the ball joint end only The hole for the pin must be exactly positioned to pass through
9. ck blade screws are tightened firmly If necessary and as a last resort use balancing kit provided to settle the wobble Make sure bracket is tight against ceiling and the ceiling and the ceiling structure are not moving Do not use counter sunk screws or unsuitable fasteners to attach bracket to ceiling Use the screws provided Fan is noisy Check all screws and parts are secured firmly Ensure there are no loose parts moving inside the motor housing Make sure the fan is installed with a Hunter Pacific International wall controller only do not use solid state controllers as they will cause unpleasant motor noises If the customer is in an area receiving ripple control signals off peak services then the fan may make an audible noise caused by the ripple control signal This is not a defect and signal reduction filters are available for additional cost National Warranty Line 1300 360 280 Monday to Friday from 9am to 5pm EST Only available within Australia 1 Do not attempt to operate the fan or optional light kit with any wall control that is not approved by Hunter Pacific International for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set 10 Typhoon Installation TACT pad Manual Quick Checklist
10. e isolation switch has been installed 10 Check Electrician s details have been recorded onto the back page of the Fan Owner s Operations and Warranty Manual 1 Do not attempt to operate the fan or optional light kit with any wall control that is not approved by Hunter Pacific International for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set 11 HUNTER PACIFIC I N T E R NATIONAL Typhoon Typhoon 7 5 6 MACH mach L J macha FOR ANY INSTALLATION QUERIES PLEASE CALL National Warranty Line 1300 360 280 Monday to Friday from 9am to 5pm EST Only available within Australia HUNTER PACIFIC INTERNATIONAL Building 8 256 New Line Road DURAL NSW 2158 TYPM2IMV1 0
11. ted in accordance with the wiring rules AS NZS 60335 1 C1 7 12 2 An RCD may fulfill this function if suitably labeled For safety and to protect your warranty the following must be taken into account when installing and operating the product s a DO NOT USE SOLID STATE WALL CONTROLLERS Neither leading nor lagging edge controllers will give satisfactory performance Wall controls must only be types approved for use by Hunter Pacific International b The fan light and bracket must be earthed c Fan and light must be run from the same final circuit d Mounting bracket must be firmly screwed to a solid structure such as a concrete ceiling steel structure or timber framing If additional bracing is added it must be firmly secured to the rafters and not left floating on the ceiling Special mounts such as T hooks are available for certain types of installation e After installation fan blades must be at least 2 1 m 7 feet above floor level IF THERE ARE ANY PROBLEMS WITH THE PRODUCT AT TIME OF INSTALLATION THE INSTALLER MUST CONTACT THE WARRANTY HOT LINE NUMBER 1300 360 280 BEFORE LEAVING THE JOB SITE PLEASE DO NOT REMOVE THE FAN FROM THE CEILING ONCE INSTALLED UNLESS INSTRUCTED TO DO SO Typhoon Installation IMACH pad Manual Parts List Tyohoon Mach 2 Metal and 316 Stainless Steel ae Hanger Bracket ne Hex Head Screw Canopy Screws 7 ae Ball Joint a Top Blade Screw Canopy o
12. the centre of the rod drilled straight and horizontal When installing a 1 8m extension rod the wiring will need to be extended and joined This should be done using crimp style connectors and properly insulated The distance from the bottom of the blades to floor must not be less than 2100mm 9 Typhoon Installation STAC aD Manual Trouble Shooting Tips for Electricians Fan will not start Check that the reversing switch is pushed into its Summer or Winter position Check wire connections in the wall switch and terminal blocks ensure all wires are making proper contact Check isolation switch is on Fan is not responding to the wall controller Check the speeds on the wall controller has been wired correctly and are making proper contact Brown speed 1 Purple speed 2 Red speed 3 Check wires in the terminal block are connected properly wires should be stripped back at the connection point and unused wires should be sealed and capped off Check that the reversing switch is pushed into its Summer or Winter position Fan is not responding to the remote control if fitted Check for flat battery Make sure the dipswitch settings in the hand piece and the remote receiver match Fan is wobbling Check the ball joint slot is locked onto the hanger bracket tab Make sure blades are a matching set the figures on matching sets of blades should be identical with the numbers varying within 3 grams of each other Che
Download Pdf Manuals
Related Search
Related Contents
Maytag W10101295A User's Manual Saeco Xsmall Super-automatic espresso machine HD8745/18 advarsel - Festool.by CARRO PORTA SILLAS MODELO #6525 ADVERTENCIA Raisons, sens et enjeux d`une question DECT SPC Telecom 7137 User Manual Smeg LBE16AZ washing machine USER MANUAL - Kramer Electronics Japan Homepage Copyright © All rights reserved.