ACM12 Reference and Installation Manual

image

Contents

1. DIGIPLExX EVO Access Control Module V4 2 Installation Instructions P A R A DO X paradox com Printed in Canada 05 2014 ACM12 El02 Introduction The Access Control Module ACM12 is designed to be used with the Digiplex EVO System control panels Each ACM12 allows you to connect a reader a REX device a door contact and a locking device to control the access to one door If desired door contacts can also be assigned to zones in the control panel to link the doors to the alarm system This will allow you to use the same door for the access control system and the alarm system What s New 4 2 Support for six additional schedule intervals for Door Unlock Schedule Added security when disarming your system New option to disarm with access card and PIN code Technical Specifications AC Power 16Vac 20 40VA 50 60Hz Aux Power 12Vdc typical 6 00mA 1A max Battery 12Vdc 4Ah minimum No of Outputs No of Zones No of Inputs Control Panel Compatibility 2 one 50mA PGM output one form C relay rated at 5A 28Vdc N O N C 2 Door Contact amp REX device 2 Negative Trigger amp Tamper inputs Any EVO control panel Installation The module is connected to the control panel s combus as shown in Figure 1 Please refer to the control panel s Programming Guide for the maximum installation distance Devices connected to the PGM output must be connected as shown in Figure 2 Refer to Figure 5 for c
2. apply Canadian and international patents may also apply Schedule B S 12343 67 8 Digiplex EVO is a trademark or registered trademark of Paradox Security Systems Ltd or its affiliates in Canada the United States and or other countries Schedule C ee 123 45 67 8 x es a l Technical Support Schedule D n _ 12345 6 7 8 For technical support in Canada or the U S call 1 800 791 1919 Monday to Friday from 8 00 a m to 8 00 p m EST Schedule E 12345678 For technical support outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 00 p m EST SSS SSS M SSS Please feel free to visit our website at www paradox com Schedule F ee eee 123 45 67 8 Schedule G aay Maeno 123 45 67 8 Schedule H ae fe 123 45 67 8 ___EventGroup___ __FeatureGroup Sent J m oma Oe OT PGM Deactivation 018 EAT 019 E a oe 020 a 021 EEN A Only Event Groups 000 to 055 062 and 063 can be used to program the module s PGM
3. conds added to section 006 Door Unlocked Period extension 015 070 Delete All Safe Mode Access Cards 008 _ _ 001 to 255 seconds Door Left Open Interval 060 071 Delete Safe Mode Access Card 1 009 _ _ 001 to 255 seconds Door Left Open Pre Alarm Timer 015 072 Delete Safe Mode Access Card 2 Time to start pre alarm before alarm is triggered 073 Delete Safe Mode Access Card 3 010 _ 001 to 255 seconds Beep timer for Door Left Open Alarm 005 074 Delete Safe Mode Access Card 4 011 _ 001 to 255 seconds Beep timer for Door Forced Open alarm 005 Warranty 01 2 __ __ __ 000 to 255 refer to option 3 in section 004 PGM timer 005 For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www paradox com terms Your use of the Paradox product signifies your acceptance of all warranty terms and conditions 013 Door unlock schedule We strongly advise that you review and take into consideration the Limitations of Alarm Systems document available on our website at http paradox com Terms Start Time End Time SMTWHT FS H Schedule A i 12345678 2003 2014 Paradox Security Systems Ltd All rights reserved Specifications may change without prior notice One or more of the following US patents may apply 7046142 6215399 6111256 6104319 5920259 5886632 chnedule A a aa 5721542 5287111 5119069 5077549 and RE39406 and other pending patents may
4. ed Open Alarm A Disabled Enabled Card Only OFF OFF 028 _ _ __ 000 to 255 minutes 000 instant AC Restore Report Delay 005 6 Door Forced Alarm Silent A Audible PIN Only ON OFF 029 _ _ 000 to 255 minutes Stay Lock Delay 000 7 Door Forced Alarm follows A Alarm Beep Card and PIN OFF ON 030 Test PGM Activates the PGM for 8 seconds to verify if the PGM is functioning properly Restore Timer A Card or PIN ON on 032 _ 000 steady 001 to 254 pulsed increments of 8ms 255 pulsed fire PGM Output type 000 8 Reader Access Feedback Visual A Visual amp 6 Reader Locate Feedback A Visual Visual amp 033 _ _ __ 000 to 255 seconds Bypass door force alarm delay 000 audible audible 040 Access Card Serial Number Display View an access card s serial number displayed on any LCD or Grafica keypad on the combus 7 Unlock Door on Fire Alarm A Disabled Enabled When the ACM12 is in access card display mode the door connected to the module cannot be accessed 8 ACand Battery Supervision A Enabled Disabled 061 Assign Safe Mode Access Card 1 Present Card 3 Times 062 Assign Safe Mode Access Card 2 Present Card 3 Times Section Data Description Default 063 Assign Safe Mode Access Card 3 Present Card 3 Times 005 _ __ 000 to 255 x1 minute 000 Instant AC failure report delay 030 064 Assign Safe Mode Access Card 4 Present Card 3 Times 006 _ __ 001 to 255 seconds Door Unlocked Period 005 007 _ _ __ 001 to 255 se
5. led 2 pee ae TIMET IMAGAN Event A Don t MAOR when option 3 is ON Reload Lime 5 Partition 5 Disabled A Enabled 5 Card activates door unlocked schedule Disabled A Enabled 3 Nedaer Sde Mode redodd A Visual say i L31 tol Future Use NA NeR a audible i a u i E A jet ea 4 Unlock Door in Safe Mode A Disabled Enabled 5 Card and Pin required to disarm A OFF ON 7 Partition 7 Disabled A Enabled 7 Reader s green LED for Access Granted Disabled A Enabled JEE iomeeee e Canda Any Ee 7 to 8 Future use me me 8 Partition 8 Disabled A Enabled 8 Unlock on Request for Exit REX Disabled A Enabled 6 to 8 Future Use i N A Galva waewsec iam OA oponas ae SECTION 003 General Options 2 SECTION 004 PGM Options eer Option OFF ON Option OFF ON 1 Door Left Open Alarm A Disabled Enabled 1 PGM Deactivation After A Deactiva PGM Timer Section Data Description Default tion Event 023 _ _ __ 001 to 024 hours 000 Disabled Safe Mode Door Unlocked Period 000 2 Door Left Open Pre alarm Disabled A Enabled 2 PGM Normal State A N O N C 024 _ _ _ 001 to 255 seconds 000 Follow REX REX Unlocked Period 000 3 Door Left Open Alarm Silent A Audible 3 PGM Base Time A 1 second 1 minute 025 _ __ 000 to 003 Red LED Brightness 003 4 Door Left Open Alarm follows A Alarm Beep 4 amp 5 Special 4 5 026 _ _ __ 000 to 003 Green LED Brightness 003 Restore Timer 027 _ _ __ 000 to 003 Buzzer Frequency 001 5 Door Forc
6. onnection drawings for the REX device reader locking device and door contact A The door contact follows the control panel s EOL definition When EOL is enabled and the door contact is not used place a 1k92 resistor across the cT and Aux input terminals If EOL is disabled use a jumper If the REX device is not used place a jumper across the REX and Aux terminals AC Power Use a 16 5Vac 50 60 Hz transformer with a minimum 20VA as shown in Figure 1 Do not use any switch controlled outlets to power the transformer Backup Battery To power the module s door lock relay during a power failure connect a 12Vdc 4Ah rechargeable acid lead or gell cell backup battery as shown in Figure 1 Connect the battery after applying AC power A Inverting the polarity when installing the battery will blow the battery fuse Connecting the External Negative Trigger The ACM12 comes with an external negative trigger You can use a PGM from the control panel or another module to release the access control door lock The external negative trigger can also be triggered using a push button When the push button is pressed the door will unlock The PGM or push button must ground the negative trigger Connect the push button as shown in Figure 2 LED Display AC Green On when receiving AC power BATT Green On when charging and during battery tests AUX Yellow On when auxiliary output is active ERROR Red Indicates a problem with
7. t for Exit REX device is not used place a jumper across the AUX and REX terminals 1N4007 Diode Figure 6 Connecting for Firmware Upgrade CONV4USB ACM12 T Sl Ee Ds Ga RED BLK GRN YEL CV4USB l L2VGND A B GND A B RX__TX GND POWER RX RS 485 __TX RS 232 A Default setting SECTION 001 Partition Assignment SECTION 002 General Options 1 SECTION 022 Safe Mode Options SECTION 031 PGM Options 2 Option OFF ON Option OFF ON Option OFF ON Option OFF ON 1 Partition 1 Disabled A Enabled 1 Tamper Input A Disabled Enabled 1 Safe Mode Disabled A Enabled 1 Flexible PGM Deactivation Option A PGM Timer Timer 2 Partition 2 Disabled A Enabled 2 Battery Charging Current A 350mA 850mA only Deactivation 3 Partition 3 Disabled A Enabled 3 Reader s red LED to follow partition s status Disabled A Enabled event 4 Partition 4 Disabled A Enabled 4 Reader s beeping to follow partition s status Disabled A Enabled Bl SaMede aces Disabled A Enab
8. the module RX Green Flashes when receiving information from the panel TX Green Flashes when transmitting information to the panel Table 1 Special Display RX TX Condition ON OFF JOFF Combus is shorted No clock No data or Wrong data Invalid Combus address Too many modules Future Use Combus lines reversed YEL and GRN Fash __ Cembuspoweristoolow Connection Diagrams Figure 1 Connecting the power and combus Disconnect the battery before AUK wii ii A replacing the fuse L aux JPGn TMP RED us veL Digiplex Digiplex EVO series control panel Rechargeable Battery 12V 4Ah min AWG 14 single 4 conductor solid copper wire To metallic enclosure Cold water pipe grounding Ground clamp Transformer Sharing Transformer Sharing Use one transformer to power multiple modules with transformer sharing Connect to another module compatible with transformer sharing From transformer Press to toggle the AUX output Figure 2 Additional Connection Information putt ttt i pfi ttt BEE See N ODIA DISI DISIN a a a o a To PGM output External Tamper Switch N C And Or External Negative Trigger CT REX DO D1 BEEP RED t auxe PGM TMP RtU ta pe TEL If the ACM 12 loses communication with the reader it will show up as a Module Fail to Com trouble Connected up to 300m 1000ft away Reader ACM 12 1 RED
9. to 2 BLK to 3 GRN to DO 4 YEL to D1 Only connect one reader per ACM12 R915 R910 not shown is connected the same way Figure 4 Connecting a 7 Wire Routing Cable oo CT REX DO D1 BEEP RED GREEN BUS N E ORANY FLOW If you use a routing cable use a shielded A routing cable Do not connect the routing cable s shield to the reader s shield Only connect the routing cable s shield at the ACM 12 Connected up to 152m 500ft away Connect Reader ACM 12 1 Red to 2 Black to 3 Green to DO 4 White to D1 5 Brown to Beep 6 Orange to RED 7 Yellow to GREEN Only connect one reader per ACM12 CR R880 BL CR R885 BL not shown is connected the same way A When connecting the diode to the door lock be sure to Figure 5 Connecting Access Control Devices CDESS0SS ZSO oers a oe CT REX DO Dl BEEP RED GREEN o EOL required on REX eres devices 1 k 2 Door contact Paradoor 460 REX device must be must be connected to REX terminal connected to cT terminal Follows control panel s EOL definition connect the cathode of the diode to the positive voltage and the anode to the negative voltage Cathode Anode If the door contact is not used install a jumper ora 1kQ resistor across the AUX and CT terminals depending on the control panel s EOL definition If the Reques