Home

Installation Manual

image

Contents

1. 7 ypame Installation Manual for 603AB 603ABK 603HB 603HBK Wireless Intercom System Installation 1 Before installing fully test the range of the system Wire the unit as per wiring diagram place the equipment in the desired location and test operation 2 Ensure that the gate transmitter receiver unit is installed to facilitate line of sight with the property or reception area To achieve best results mount the unit as high as possible from the ground Should you need to extend range you can mount it on a small pole to elevate it a few meters from the ground House or reception 150m area Typical Entrance Pillar For longer range applications locate the handset near a window at front of property ri gt m Note Wood and glass only l f reduce signal strength by Transmitter receiver Keep 10 20 Masonry will reduce i away from ground as high as signal strength by 20 50 ni possible For best results do per wall Metal can totally not install too close to sources block signals of electrical interference e g gate automation panel A 3 It is recommended to charge the handset for 7 8 hours before use 4 Power up the handset after inserting the batteries 5 Wire the door station and transmitter receiver according to the diagram below 3 Remove the top two security screws as shown Do NOT remove the
2. to show the issue please feel free to send it NOTE THIS IS BY FAR THE FASTEST AND MOST SUCCESFUL WAY TO SOLVE YOUR PROBLEM PHOTOS AND VIDEOS ARE THE NEXT BEST THING TO BEING THERE OPTION 2 LODGE YOUR ENQUIRY LOCALLY SLOWER BUT CAN STILL BE EFFECTIVE Make contact with the store of purchase Branch staffs are typically not technicians and dependent on their length of service will have varying degrees of technical knowledge If they cannot help however they will certainly either source help locally from their technicians or make contact with the service technicians on your behalf OPTION 3 SERVICE CALL WITH AUTOMATIC SOLUTIONS TECHNICIAN SLOWEST METHOD If you fall within the local branch service area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local workloads The cost is a service fee which includes the first half hour and the hourly rate thereafter If any Automatic Solutions provided parts are found to be defective and within warranty these will be provided free of charge NOTE If you suspect that any parts are defective and within warranty you may wish to consider option 4 A note on this option If you decide on this option you will be asked to sign an authorisation to proceed which will provide legal authority and payment security This form has three options available of which only the first two are available to you The third option is for warranty repairs only fo
3. bottom screws The front door will hinge downwards to allow access for mounting holes and connection terminals ARCHITECTURAL HOODED MODEL MODEL Note The protective film on the front of the intercom should not be removed until fully installed Mount AB model to wall with Never drill holes in 10mm x 50mm the top of the PEGs large wall enclosure Cable anchors to entry should be s prevent removal through the bottom or theft 602 Range 8 meters max o Foil screening Screened CAT 5 nbs pee aroun keep short for better audio wires for best J J performance 9 12v Note For improved audio 9 Me 3 a 1 Y de T e performance the shield onnections GND lO sziig wire can be connected to shield OOOOOOOO bolts on metal housing of wire i speech panel O EN Cr N No 18 3 Volt free Relay output as 4 sec pulse 3 Code Q H EEEE EE button H INT Lock QO j O P1 inhib _ i Sense lt gt 3 GND Hl DU out i KorA i dc in f S Shielded CAT5 cable Ue OUT1 OUT2 Keypad Connections ABK model Note Keypad volt free output s needs connected to gate control panel or electric door lock as well as relay output from the intercom controller PCB Parallel connect C and N O contacts for electric gate controller or strike lock Ser
4. en closed this disables all codes for relay group 1 except super user and duress codes Interlock Output NPN transistor output open collector max power 24v dc 100mA sink Used to operate a door in conjunction with another keypad or prevent two doors being opened at the same time Tamper N C Normally closed tamper switch This can be used in conjunction with a tamper switch on a box or enclosure to prevent tampering This can be connected to an alarm system SELF INSTALL NEED TECHNICAL ASSISTANCE OPTION 1 DIRECT WITH THE SERVICE DESK QUICKEST AND MOST EFFECTIVE METHOD Submit your enquiry direct with the service desk at service automaticsolutions com au The service desk has the most experienced staff in Australia to help with your problem but they need your help Describe your problem in detail and as clearly as possible Don t forget to include a telephone number Be certain to detail which model or models of you are working with Send photos of the installation they love photos The people at the service desk are good but they are even better when they can see the installation Send photos of the overall scene so they can see the entire installation Also send photos of the wiring to the control board and any other part of the installation you think is relevant Send video if appropriate Smartphone s these days take remarkably good video in small file sizes which can be emailed in a moment If your problem needs a video
5. ies connect C and N C contacts for magnetic lock Testing 1 Check all connections are correct before switching on the power 2 Press the call button on the speech panel 3 The handset should ring 4 Press the button to answer the call and check two way speech 5 Press to check the door gate release function works Handset amp Operation ADJUST VOLUME Press or V to adjust volume level and press MENU to select and save Battery Reception Level CHANGE RING TONE indicator Press lt and the unit will ring under the currently select tone Press V and A to cycle through available ON OFF ring tones Press MENU to select Voicemail Symbol Vibration ON OFF and save CHANGE LANGUAGE Charging Press gt and the unit will display the base currently selected language 1 English Press V and A to eee cycle Press MENU to select and Be Button save VOICEMAIL When the door station is pressed and not answered within 40 seconds the visitor can leave a message Once complete the handset will display the M symbol Up to 16 messages can be saved To listen to voicemail press MENU to play If there are more than 1 message press A and Y to select the message required and press MENU to play lt Pause Exit gt Continue o Delete long press delete all SET TIME ON DISPLAY Press MENU for 2 seconds The hour digits will begin flashing Press or VY to adjust Press MENU to cycle fr
6. ing mode Enter new programmers code fo 4 Location 4 8 digit code Validate Record or Delete user codes 1 0 o Lo o a 10 relay 1 codes 2 add code Memory locations 1000 available 5 delete code 000 999 for relay 1 20 relay 2 codes 001 100 for relay 2 100 available 001 100 for relay 3 30 relay 3 codes 100 available Pin code 4 8 digits Validate Example Add user 31 to have access code 5555 operating relay 2 Em PI Lo B outs Sass e Group 2 Add code Location 31 Pin code 5555 Validate 10 relay1 OG 8 20 relay2 Delete code ID location to be deleted Validate 30 relay3 Delete all codes in a grou e 9 9 e 10 relay1 group 20 relay2 group 30 relay3 group Super delete code Validate Programming Relay output times amp modes foo 1 e e 9 9 9 51 relay1 0 start stop toggle mode latching 52 relay2 1 99999 seconds momentary operation 53 relay3 Validate Programming SUPER user code Super user code is an optional feature which allows the same code to operate outputs 1 2 or 3 Le e Location 4 8 digit code Validate Using super user code Using standard user code To use standard code simply enter the 4 digit code Note Remember to exit programming mode with before testing user codes Restoring defaults While in programming mode enter the following to delete all codes and settings apart from the Master code this ca
7. n take up to 2 5 minutes e lelle e When the master code is forgotten 1 Wire a push button or replicate with wire link across the EG IN terminal and GND 2 Switch off power for 1 minute 3 Switch ON power during the first 60 seconds press the EG button once to enable the function 5 Enter the following code Lej lelle i LIL The keypad should now be in programming mode ready to accept new data Additional keypad information Note These features are not commonly used EG IN EGRESS INPUT Connect a push button between this terminal and GND When Egress button is pressed output 1 will be activated for the programmed delay Egress button is usually located inside a building and used as a push to exit K or A KEYPAD ACTIVE OUTPUT An NPN transistor open collector output It switches to ground for 10 seconds on each key touching This can be used to turn on lights CCTV camera or buzzer to notify a guard The rating of this output is lc max 100mA sink Vc max 24VDC DU OUT DURESS OUTPUT An NPN transistor open collector output It switches to ground after the Duress Code is entered Use it to trigger an alarm zone or turn on a buzzer to notify a guard Ic max 100mA sink Vc max 24VDC DOOR SENSE N C connected to GND to be connected to a normally closed door contact It can be used to generate a door open alarm or door forced open alarm O P 1 Inhibit Normally open Wh
8. om hour setting to minutes and repeat Press MENU a third time to exit and save changes Coding another handset to the System To add an extra handset to the system follow the sequence below 1 Press and HOLD the code button on the door station for 3 seconds until the LED s on the bottom of the board start to flash 2 Press and hold the Code button on the new handset ignoring the first short tone until you hear a confirmation tone Di Do Do This may take up to 10 seconds 3 Once the door station lights stop flashing then you can test the system by pressing the call button on the door station The new handset should ring If not repeat the process from the top Note For earlier models the existing master handset lights will flash after step 1 You will need to press the MENU button on the existing handset first before proceeding to step 2 above Keypad Programming only ABK models LED indicators ON when incorrect codes entered and outputs are locked out GREEN when output 1 activated RED when output 2 activated JU LUL Fast FLASHING wrong code entered error ILLT SLOW FLASHING in normal standby mode L_ ON in programming mode L_ ON when relay 3 activated Note Programming can only begin 60 seconds after power on Enter Programming mode The unit is now in programming mode Amber LED x will remain ON 0000 is default programmers code Note Pressing again will exit programm
9. r full install customers Self install customers requiring warranty only service need to refer to option four below IMPORTANT IN SHORT THIS OPTION WILL INCUR CHARGES OPTION 4 RETURN THE PRODUCT IF BELIEVED TO BE FAULTY As a self install customer who has purchased product if you believe the product to be faulty rather than an installation or site problem you have the option of returning the product for evaluation and to exercise your right to a replacement repair or refund as applicable All returned product is forwarded immediately to the service technicians for evaluation and response There are two main methods available to return product e Direct to the service centre this is the quickest method as it cuts out the branch delay e Via the branch of purchase slower because of the delay at the branch When choosing this option you need to complete a product return form This form gives you all the information on procedure involved and where to send to These are available at the branch of purchase can be emailed to you contact your branch or available here http automaticsolutions com au page warranty php