Home
USER'S MANUAL
Contents
1. AlcoSense SURETY Fuel Cell Breathalyser on datech j AlcoSense SURETY USER S MANUAL Thank you for purchasing an AlcoSense Surety breathalyser We hope you enjoy owning your AlcoSense Surety breathalyser If you have any questions regarding the unit or want to speak with us further please visit alcosense com au or call 1300 800 200 between 9am and 5 30pm Monday to Friday Table of Contents C omP ONE MitS eect ee ee ee eer ete ee a ee ene ee 4 COMEDI S ee ere a are E tetas nese E O S OPR ee esenaete ee ee 4 Pale DA A GONE ceka Re Re 5 BAS ICO R OR E N 6 Downloading Data AndaLink Software 7 FastiMode Operations a e e E E ss ose ass 8 Troubleshooting Warning Dis pe oo 00000 2 S o A E tans ract cron ssenat ersten es 11 Optional Function Bluetoothk a a 19 Replacing Batteries Sensor Module 24 S PECIECALIOMS Seeder abba E 26 DISCLAIMERS axaiescesesanssneannsnssinsionssegnen osseuses 27 M asurements amp Conditions Or SST 22 28 Warranty Details een E ur 29 RESENTON Ee SSES roo aooo esti seereere cen tetecss sil AlcoSense Guarantee BLOW andatech Lamp IrDA window Display Up button Menu down button Power select button Battery cover release OO el Oy Ol ee Seni Battery cover Contents 1 x Breathalyser o x Mouthpiece 1 x Hand strap 1 x USB cable for PC 2 x Batteries 1 x Manual 9 Sensor Module 10 Handle of sensor modu
2. 17 05 45 Result 0 000 BAC Test No 00045 Data No 250 500 Select data using UP DOWN button Press and hold the power button for 1 2 seconds until selected data is printed Range c Range Bluetooth Range Last data Selected data 00001 to 00250 Range Next Press the power button then select the data range using UP DOWN button Press the power button again Range Range 00001 to 00250 00001 to 00250 Next Next Select next for printing and press the power button The selected data will be printed 20 Bluetooth Not available means no Bluetooth is Not available connected Note Please check printer before using bluetooth function OFF ON 2nd Switch OFF Bluetooth OFF IrDA ON 3 2nd Switch ON Bluetooth ON 4 IrDA OFF 2nd switch on right side of the battery lot of the mobile printer has to be in ON status like the diagram above B Bluetooth mode setting in Menu p 16 Set date Bluetooth LI Set time Bluetooth ON Printer D N XXXXXXXXXXXX Save to SD Card Visible Change PIN Scan for devices Bluetooth Change PIN code Enter Bluetooth mode 21 1 Bluetooth function ON OFF Bluetooth Bluetooth ON D N XXXXXXXXXXXX Visible Scan for devices Change PIN code 2 Visible Bluetooth Visible a Bluetooth ON D N XXXXXXXXXXXX Visible for 120 sec Visible
3. can give any indication of blood alcohol level A person s BAC Blood Alcohol Concentration can only be accurately measured by the administration of a blood test This product only measures breath alcohol content which in turn only gives an approximate indication of blood alcohol concentration In these circumstances the user of this product should not rely on the information provided thereby as an accurate indication of their blood alcohol concentration or of their level of intoxication or of their fitness to drive and in particular should not take any action in reliance on such information as the product can provide no more than an indication of alcohol on the breath If the user of this product makes any decision or takes any action based on the use of the product such decision or such action shall be at the sole risk of the user and neither the manufacturer nor the supplier assumes any responsibility for such decision or action In particular neither the manufacturer nor the supplier shall be in any way liable if the user of the product asserts that the product led them to believe they were fit to operate a motor vehicle and are subsequently found not to be so fit Measurements amp Conditions for Test e Use a clean mouthpiece for each test e Do not allow samples containing smoke tobacco or other chemical products to enter the unit as damage to the fuel cell can occur e There must be an interval of at least 15 minutes afte
4. failure does not amount to a major failure The Guarantee The product is guaranteed to be free from defects in workmanship and parts for a period of 1 year from the date of purchase Defects that occur within this warranty period under normal use and care will be repaired replaced or refunded at our discretion solely at our option with no charge for parts and labour The benefits conferred by this warranty are in addition to all rights and remedies in respect of the product that the consumer has under the Trade Practices Act and similar state laws Proof of Purchase This warranty is valid for the original purchase and is not transferable Please keep your purchase docket or receipt as proof of purchase and as proof of date on which the purchase was made The purchase docket or a copy or receipt must be presented with the warranty when making a claim under this warranty Service during the Warranty Period To claim for warranty contact us on 1300 800 200 or info dandatech com au to get an RA Return Authorisation Number Ensure that the RA is clearly stated on the outside of the packaging and that the product is properly packaged so that no damage occurs to the product during transit Shipping of the product back to us for warranty will be at your cost A product return without the RA or proof of purchase will not be accepted 29 Extent of Warranty This warranty is limited to defects in workmanship or parts All defect
5. latest 500 test results Last maintenance Back to test Last tests E Calibration Last maintenance O gt 24 12 2014 Total test count Accuracy check Date amp Time 24 12 2014 Measurement mode The date of last calibration and accuracy check 3 Total test count Back to test Total test count Last tests E Last CAL 00035 Last maintenance Fail Cnt 00500 Total test count Sensor 00500 Date amp Time Lifetime 00995 Measurement mode B Last CAL The number of tests after the last calibration Fail Cnt The number of failed tests Sensor The number of tests on installed sensor module Sensor module stores number of tests Lifetime Total number of tests on the device 4 Date amp Time Back to test Date amp Time Last tests Last maintenance Date 09 12 2014 Total test count Time 19 44 03 Date amp Time Measurement mode Checking date and time ofthe device 12 Back to test Measurement mode G Last tests Last maintenance V Normal mode Total test count Fast mode Date amp Time Measurement mode A Normal mode Measure alcohol content in human breath Test result is displayed in digits For further instructions refer to page 6 Basic Operation B Fast mode Check for the presence of alcohol in breath Test will be quicker and more convenient The result is displayed as P
6. 17 05 45 Range Result 0 000 BAC Test No 00045 Data No 250 500 Select data using UP DOWN button Press and hold the power button for 1 2 seconds until selected data is printed c Range Cable Range Last data Selected data 00001 to 00250 Range Next Press the power button then select the data range using UP DOWN button Press the power button again 00001 to 00250 Next Next Select next for printing and press the power button The selected data will be printed Bluetooth Optional function A not available B Available Printer Printer Cable Cable Bluetooth Bluetooth none YJ 300T 12030075 IrDA IrDA Please check that your device enables Bluetooth function For more information refer to page 19 Optional function Bluetooth IrDA Printer IrDA Cable Last data Bluetooth none IrDA Select last data and close the device s IrDA window to the printer s IrDA window then press the power button 16 Ensure that both IrDA windows are facing each other Last test result will be printed 2nd switch OFF Bluetooth OFF IrDA ON 2nd switch ON Bluetooth ON IrDA OFF IrDA and Bluetooth function are not compatible so check the printer switch which is in battery lot in mobile printer D Save to SD card Set date Save to SD card Set time Do you want to Set languge overwrite Save OK Display Printer Yes N
7. PASS or F FAIL No mouthpiece is needed simply use the sampling cup provided For further instructions refer to page 8 Fast Mode Operation 6 Set date Adjust date format and date Last tests Set date ope maintenance otal test count A Format dd mm yyyy Date amp Time Date 24 12 2014 Measurement mode Set date 7 Set time Adjust time Last maintenance Set time Total test count Date amp Time Format hh mm ss Measurement mode d Time 14 07 19 Set date Set time Set the language for display Available options English Russian Korean German Spanish Italian Total test count Set language Date amp Time V English Measurement mode Russian Set date Korean Set time German Set language Spanish Menu is available in English only Backlight Date 8 Time Backlight Measurement mode Set date v ON Set time OPF Set language Backlight Printer Setting printer connection mode Measurement mode Printer Set date Cable Set time Bluetooth Set language none Backlight IrDA Printer Cable Ensure printer is turned on and printer cable is connected prior to selecting 14 Cable Last data Selected data Range Press the power button the last data can be printed b Selected data Cable Selected data a Last data Date 24 12 2014 Selected data Time
8. Scan for devices Change PIN code e Bluetooth connecting device with AndaLink Software in PC e For the installation please refer to AndaLink Manual in AndaLink Software See page 7 3 Scan for devices Bluetooth Scan for devices lt Bluetooth devices Bluetooth ON YJ 300T11080479 D N XXXXXXXXXXXX Pairing OK Visible m Scan for devices D gt Change PIN code Scanning for 30 sec e Searching for available Bluetooth devices takes around 30 seconds e Select the device and press button e Then Pairing OK will show on the LCD with beep sound from mobile printer 22 4 Change PIN code Bluetooth Change PIN code Bluetooth ON D N XXXXXXXXXXXX PIN Visible Scan for devices Change PIN code D e For the Bluetooth connecting with PC e For the setting please refer to AndaLink manual in AndaLink software See page 7 The PIN code for connecting with Printer is 1000 Bluetooth Not available The device is not available for Bluetooth connecting Not available will be shown on the LCD Please check your device is Supporting Bluetooth function 23 Replacing Batteries Sensor Module Battery cover 1 Push battery cover release to the right and slide the cover down to remove it NO Remove the batteries Caution Before taking out the sensor module remove the battery 3 Grab handles to release
9. first To register your product and book in a calibration please go to my andatech com au or contact Andatech Corporation Pty Ltd Hotline 1300 800 200 Website www alcosense com au AlcoSense Guarantee We take pride in the quality and integrity of our breathalysers and it s important to us that you get the most out of using our products With this commitment in mind we will extend the warranty of your AlcoSense Breathalyser for up to 5 years from the original purchase date as long as you keep it calibrated every 6 months from the date of purchase Go to andatech com au alcosense guarantee for more information and for terms and conditions EASY WAY TO EXTEND YOUR WARRANTY Sign up for a Breathalyser Management Plan and save time and money each 4 Set and forget year It s the easiest way to get your Save costs breathalyser calibrated every 6 months and saves you the hassle of booking it in each time M Priority calibration Go to andatech com au breathalyser management or call 1300 800 200 for more information AlcoSense andatech i andatech Andatech Corporation Pty Ltd www andatech com au 1300 800 200 v1 0 Updated 14 08 2014
10. ive products or parts will be repaired or replaced This warranty does not cover manuals and packaging Normal Wear and Tear This warranty does not cover normal wear and tear to the product or parts Exclusions This warranty does not cover e Calibration costs e Any defect caused by an accident misuse abuse improper operation lack of reasonable care unauthorised modification loss of parts tampering or attempted repair by a person not authorised by the distributor e Any product that has been damaged by a lightning strike either directly or indirectly or a main power surge or liquid ingress e The product if it is located outside of Australia e Any damage caused by improper power input or improper cable connection 1 YE WA RAR 30 31 WARRANTY The manufacturer warrants for 1 year from the date of purchase the product to be free from defects in workmanship or material excluding recalibration under normal use The manufacturer s obligation under this warranty Is limited to replacing adjusting or repairing the unit if returned along with proof of purchase This warranty Is void if the unit has been tampered with damaged or abused in any way Visit my andatech com au to register your warranty online and receive calibration reminders CALIBRATION AND SERVICE Andatech recommends the AlcoSense Surety to be calibrated every 1000 tests or for Australian Standards requirement every 6 months whichever comes
11. le 11 Batteries 12 USB printer connector 13 Hand strap 14 Mouthpiece receptacle 15 Mouthpiece 16 Sampling cup for fast mode 1 x Leather pouch 1 x Sampling cup for fast mode Sold separately Printer Bluetooth SD card 1 Attaching the hand strap Push the battery cover release to the right side and pull the battery cover down and remove it Insert hand strap into the small hole in the housing Loop it around the hook on the inside of the hole then replace battery cover 2 Fitting the mouthpiece Insert mouthpiece into the port on the top of the device securely with a click A new mouthpiece is to be used for every person tested Mouthpiece can be used with orientation to right or left side The same applies to the sampling cup for fast mode D e 2014 May 18 14 44 SIN 00000000000 Analyzing wait Turning the unit on 1 Press the power button a Press and hold the power button to see device information including serial number date and time 2 Wait until the unit has warmed up and BLOW is displayed Taking a test Install a mouthpiece While BLOW is displayed blow slowly and steadily through the mouthpiece until the tone stops Analyzing Wait is displayed while the breath sample is processed Test results will be displayed for 15 seconds If a printer is connected a test receipt will print Taking co
12. locks and slide the sensor down 24 25 4 Take out the sensor module 5 Reassemble in reverse order 6 Ensure sensor is fully seated and both locks are engaged Caution Charging batteries while in the device will cause damage Indication of BAC 0 000 2 500 o 0 000 0 250 BAC 0 000 1 250 mg l BrAC 0 000 2 500 g l 0 125ug 100ml 0 1250ug l Warm up time 5 seconds 2 minutes Response time Within 10 seconds at 0 100 BAC Accuracy 0 005 BAC at 0 100 BAC Ambient conditions Operation 5 C 40 C Storage 10 C 50 C Sensor Replaceable fuel cell sensor Calibration Every 1000 tests or 6 months Australian Standards Requirement whichever comes first Use mouthpieces Only compatible with AlcoSense mouthpieces Power supply Two 1 5V AA Alkaline Batteries Battery change Approx 3 000 tests Weight 198g including batteries Dimensions mm 133 height x 64 width x 33 thickness Measurements memory Approx 500 measurements without SD card Device No Date Time test result number 26 D 27 isclaimers This product must be used strictly in accordance with the instructions in this manual This product is intended to provide the user with an indication of alcohol on the breath However neither the manufacturer nor the supplier gives any warranty express or implied that the product
13. ly Installed 8 Error with using temperature Over Temperature ee The device is not functional under Observe Operating 5 C and over 40 C Temperature Range 9 System Error 1 Condenser charging error System Error 1 Contact your local distributor Service required 10 System Error 2 Sensor leakage System Error 2 y Contact your local distributor Service required 11 Print Cable Not Connected Cable If there is no cable connection Print Cable LCD will display Print Cable not Not Connected Connected 10 Back to test User PIN code 0000 To enter Menu mode press the power button then push the menu button Press the power button again to key in user pin code Default 0000 Contents of Menu Last tests Last maintenance Total test count Date amp time Measurement mode Set date Set time Menu Last tests Back to test Last tests Last maintenance Total test count Date amp Time Measurement mode Set language Backlight Printer Save to SD card Bluetooth Change user pin Set contrast Last tests Date Time Result Test No 24 12 2014 17 05 45 0 101 BAC 00045 Data No 250 500 Last test result is showing You can check up to 500 accumulated test results by pressing the UP DOWN button Data No Test result number the number of stored test results The
14. nsecutive tests 1 After previous test results have been displayed WAIT will display while the unit processes any remaining alcohol from the previous sample Once the unit has finished processing the previous test BLOW will be displayed Unit is ready to accept another sample Powering the unit off 1 Press and hold the power button 2 Power Off will be displayed Power Off Power Off 2sec 1sec 3 Continue holding the power button until the unit is powered off approximately 3 seconds Auto Power Off Auto Power Off 1 If no activity is detected for 4 minutes the unit will automatically power off to save batteries p If the printer cable is connected or the unit is in Fast mode Auto Off time is extended to 15 minutes Downloading Data AndaLink Software Test results are saved onto the device Results can be downloaded to your PC via the AndaLink software To download AndaLink software go to downloads andatech com au Fast Mode checks for the presence of alcohol in a breath test and provides a fast Pass Fail response Individual mouthpieces are not needed use the sampling cup Set the measurement mode to Fast mode in the menu to enable fast testing EE e Analyzing Please wait A 2 an 1 SL P 1 Turn the unit on Wait for the unit to display Blow an F will display in the upper right corner to indicate unit i
15. o Save to SD card If you select yes data in SD card will be deleted and data in the device will be loaded to SD card Save to SD card lt Save OKI If there is no SD card Not available will be displayed Set time Set languge Display Printer Save to SD card Bluetooth This function is optional Please check your device is operating in Bluetooth mode 3 Change user pin Set languge Change User PIN Display Printer PIN 0000 Save to SD card Bluetooth Change User PIN Setting new user pin Password save will be shown after setting 4 Set contrast Set contrast Use arrows to adjust contrast 0 Select power button to confirm 51 and go back Contrast 36 18 Optional Function Bluetooth A Printer with Bluetooth in Menu p 14 Printer Cable If there was a printer connected Bluetooth before the device remembers it YJ 300T11800479 and printer serial number will be IrDA shown as diagram on the left Printer Cable Bluetooth IrDA Waiting 9 sec Enter Bluetooth mode Waiting time will be shown Orange and green lights on the printer button indicate successful connection a Last data Bluetooth Last data Selected data Press the power button the last Range data can be printed b Selected data Bluetooth Selected data lt Last data Date 24 12 2014 Selected data Time
16. r alcohol consumption as alcohol residue in the mouth may give a false reading Such residue may also be left by aromatic drinks mouthwash medicines and drops as well as by belching and vomiting Rinsing your mouth with water or non alcoholic drinks does not substitute for an Interval e A person s blood alcohol concentration BAC can continue to rise for up to 2 hours after drinking alcohol If a caution results or a result is close to the designated BAC it is recommended to wait and retest after 20 minutes e It can take 10 hours or more for a person s BAC to return to zero after a high BAC has been reached A further test should be carried out later in the day or the following morning DO LIABILITY FOR PROPER FUNCTION OR DAMAGE The liability for proper functioning of the instrument is irrevocably transferred to the owner or operator in the event the Instrument is serviced or repaired by personnel not employed or authorised by Andatech In such an event the warranty will be void 28 arranty Details It is our aim to provide you with quality products that you can trust Our products come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or a refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable guality and the
17. s in fast mode Blow into the sample cup unit the unit beeps Results will display as Pass or Fail If a printer is connected a test result will print When BLOW is displayed subsequent tests can be performed While in Fast Mode a standard test can be taken as follows Up Button k BLOW gt BLOW E Up Button E When the unit displays BLOW press the amp UP button to cycle between Fast and Normal mode F Fast Mode N Normal Mode Unit will return to fast mode automatically after test in normal mode Flow error during test Breath sample was not steady enough or it was not long enough Wait for the device to return to ready condition Blow with a long steady breath Continue blowing until tone stops Flow Error Test result exceeds 0 250 BAC OLT Battery power is low Please replace the batteries Change Batteries E C 100 70 30 0 Battery symbol i Calibration service is required please contact your local distributor for further instructions Calibration is required every 6 months or 1000 tests whichever comes first Calibration information is stored in the sensor module Calibration Required Number of tests after calibration Memorised in sensor module C Test No Number of tests with device Memorised in device L Test No Sensor Error Remove and reinstall the sensor unit Ensure sensor is fully Ensure Sensor Seated Correct
Download Pdf Manuals
Related Search
Related Contents
Chlorilong Bloc-Productsheet-FRANCE.indd Préface - Le Publieur Le cancer colorectal - Endirect-professionnels-de System and method for retaining clients by automated services Bedienungsanleitung Sony Xperia T3 style Radio Shack 40-CHANNEL User's Manual Spinfoamer Carpet Shampoo Appliance Samsung 55" UHD 4K Curved Smart TV HU8700 Series 8 Manual de Usuario Kenwood TM-271A Mod for PL Decode Logic Out Copyright © All rights reserved.
Failed to retrieve file