Home

show technology LED quadPar 7 installation guide user manual

image

Contents

1. alculating working load limits installation material being used and periodic safety inspection of all installation material and the projector If you lack these qualifications do not attempt the installations yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property Use only professional trussing system if the item shall be lowered from the ceiling or high joists Never let the device swing freely in a room jJ roi QuadPAR 7 amp QuadPAR 18 CAUTION Overhead Items may cause serious injuries when crashing down If there is concern about the safety then DO NOT INSTALL the device DANGER OF FIRE When installing the device make sure there is no highly flammable material decoration articles etc within a distance of min 0 5m Mount the projector with the mounting bracket to your trussing system using an appropriate clamp For overhead use always install a safety rope that can hold at least 10 times the weight of the fixture You must only use safety ropes with quick links with screw cap Pull the safety rope through the hole in the mounting bracket and over the trussing system or a Safe fixation spot Insert the end in the quick link and tighten the safety screw The maximum drop distance must never exceed 20cm A safety rope which already held the strain of a crash or which is defective must not be used again DANGER TO LIFE Before tak
2. c RGBW R 0 255 G 0 255 B 0 255 W 0 Manu 255 Dim mode DIM 1 DIM 2 DIM 3 Back Lite ON 10S 20S 30S Info TEST Fix Hours Version Address DMX address 1 512 Channel personality 10 ch set max dmx address to 502 5 ch set max dmx address to 507 4 ch set max dmx address to 508 Master Slave Master Slaver 7 PR Pro QuadPAR 7 amp QuadPAR 18 3 0 DMX Allocation 4CH MODE CHANNEL VALUES FUNCTION 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 4 000 255 White 0 100 5CH MODE CHANNEL VALUES FUNCTION 1 000 255 Master Dimmer 0 100 2 000 255 Red 0 100 3 000 255 Green 0 100 4 000 255 Blue 0 100 5 000 255 White 0 100 10CH MODE CHANNEL VALUES FUNCTION 1 000 255 Master Dimmer 0 100 2 000 255 Red 0 100 3 000 255 Green 0 100 4 000 255 Blue 0 100 5 000 255 White 0 100 000 010 No function 011 030 R100 G0 100 BO 031 050 R0 100 G100 BO 051 070 RO G100 B0 100 071 090 RO G100 0 B100 091 110 R0O 100 GO B100 111 130 R100 GO B100 0 131 150 R100 G0 100 B0 100 151 170 R100 0 G100 0 B100 W0 100 6 171 200 R100 G100 B100 W100 J roi QuadPAR 7 amp QuadPAR 18 201 205 Colour Temperature 1 Warm 206 210 Colour Temperature 2 211 225 Colour Temperature 3 216 220 Colour Temperature 4 221 225 Colour Temperature 5 226 230 Colour Temperature 6 231 235 Colour Temperature 7 236 240 Colour Temperature 8 241 245 Colour Temperat
3. ing into operation for the first time the installation has to be approved by an expert roi QuadPAR 7 amp QuadPAR 18 1 2 Power Connection I CAUTION Never leave this device running unattended Every person that is involved with this item has to be qualified Connect item with main plug The voltage and frequency must exactly be the same as stated on the device The power plug must always be inserted without force 1 3 Cleaning and Maintenance Please make sure that safety relating and machine technical installations are inspected by a skilled person once a year Make sure before installing that all screws are tightly connected and not corroded There must be no deformations on the housings fixations and installations spots 3 No damages must be showed on the power supply cables material fatigue and sediments If the exterior of the unit is going to be cleaned please use moist lint free cloths Never use alcohol or solvents The Cooling fan must be cleaned monthly and check to ensure it is free of obstructions To clean the interior of the device please use a vacuum cleaner or an air jet however we recommend cleaning the lenses weekly to ensure the best output from your unit jJ roi QuadPAR 7 amp QuadPAR 18 2 0 Menu Navigation Menu Level2 Level 3 Auto Auto 1 Speed 0 100 Auto 2 Speed 0 100 Auto 3 Speed 0 100 Auto 4 Speed 0 100 Auto 5 Speed 0 100 Static FIX
4. le liquids for cleaning Use a dry cloth to wipe off the dust or a wet soft cloth for stubborn dirt NO USER SERVICABLE PARTS INSIDE If unit is out of service please contact your point of purchase If any troubles arise remove the power plug and contact your Pro Shop representative for repair Do not open the cabinet by yourself it might result a danger of electric shock J roi QuadPAR 7 amp QuadPAR 18 Take care with the power cable Never pull the power cable to remove the plug from the receptacle be sure to hold the plug When not using the unit for an extended period of time be sure to disconnect the plug form the receptacle 1 1 Overhead Rigging This item must be built in a way that it can hold 10 times more of its weight for 1 hour without causing any damages The installation must be secured with a secondary safety attachment The Safety attachment has to be constructed in a way that no part of the installation can fall down When rigging de rigging or servicing the fixture staying in the area below the installation place on bridges under high working places and other endangered areas us forbidden Before taking the device in operation the installation must be approved by an expert The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE Including but not limited to c
5. rot WED QuadPAR 7 amp QuadPAR 18 P User s Manual QuadPAR 7 amp QuadPAR 18 www showtech com au roi QuadPAR 7 amp QuadPAR 18 Table of Contents Safety INSTFUCTIONS cccccsecescescesceeceecescescccencessesesscescesceeces 3 1 1 Overhead rigging cccccccccccrscrscssscsssscsscssescsscessescesceecees 4 1 2 Power CONNECTION sscssssssccsccccccsccssssssseccessccacscssceees 6 1 3 Cleaning and Maintenance cccsscescesceeceeceeceeeceenees 6 Menu Setting sescsccsaesnesasassousicetsiuscavsncevsacsavessesinvietuncescevensiententac 7 DMX Allocation seseeseesoesoeseecesceeceecsecseceecreceecseceeceecsecseeeesese 8 Technical Specifications ssesseosesossooseoesoeseseeseeseccsecsescesoe 10 roi QuadPAR 7 amp QuadPAR 18 1 Safety Instructions FOR SAFE AND EFFICIENT OPERATION Be careful with heat and extreme temperature Avoid exposing it to direct rays of sun near a heating appliance Do not put it in a temperature below 41 F 5 C or exceeding 95 F 35 C Keep away from humidity water and dust Do not place the set in a location with a high humidity or lots of dust Containers with water should not be placed on the set Keep away from sources of hum and noise Such as transformer motor tuner TV set and amplifier To avoid placing on un stable location Select a level and stable location to avoid vibration Do not use chemicals or volati
6. ure 9 246 250 Colour Temperature 10 251 255 Colour Temperature 11 Cool 7 000 009 No function 010 255 Strobe Slow Fast 8 000 051 No function 052 101 Show 1 Auto program 1 102 152 Show 2 Auto program 2 153 203 Show 3 Auto program 3 204 254 Show 4 Auto program 4 255 255 Show 5 Auto program 5 9 000 255 Show Speed 0 100 CH8 052 255 000 051 Built in Dimmer 10 052 152 Dimmer 1 153 203 Dimmer 2 204 255 Dimmer3 roi QuadPAR 7 amp QuadPAR 18 4 0 Technical Specifications QuadPAR 7 QuadPAR 18 Light source 12 x 8W 500mA x 4 Light source 18 x 8W 500mA x 3 Quad colour RGBWLEDs 50 000hrs Quad colour RGBW LED 50 000hrs Beam angle 25 Beam angle 25 Power consumption 120W Power consumption 200W Equipped with Neutrik PowerCon in out Equipped with Neutrik PowerCon in out AC power 100V 240V 50 60Hz AC power 100V 240V 50 60Hz Weight 3kg Weight 5kg

Download Pdf Manuals

image

Related Search

Related Contents

  OBS-18 OBS-18DC - Parts Depot Inc.  INSTALACION DE GACETA JURIDICA DIGITAL  LG VS910 Brochure (Spanish)  Airbox Installation    

Copyright © All rights reserved.
Failed to retrieve file