Contents

1. Battery over charge Sounding three beeps every 5 seconds Battery Replacement Procedure 1 Batteries must be replaced with identical type 2 Disconnect UPS system from power source 3 Open battery door 4 Disconnect used battery Connect new battery It is important that connectors be firmly attached to new batteries 5 Close battery door 6 Properly recycle used battery User s Manual 350 1500VA 9 5Ah battery 350VA 500VA models 10 User s Manual 350 1500VA 7Ah x 2 batteries 1OOOVA models 9 Ah x 2 batteries 1500VA models User s Manual 350 1500VA 11 Troubleshooting Switch on the ON OFF switch If the power is not present please make sure your circuit breaker on the building is not accidentally turned Powerware 5110 UPS will off not turn on Reduce the amount of equipment Circuit Breaker has plugged into the Battery Backup tripped amp Surge Protection outlets of the UPS Next reset the circuit breaker by pushing it back in UPS is not turned on or battery is not connected Powerware 5110 UPS is making a continuous sound and the Overload indicator is lighted The Battery Backup amp Surge Protection outlets are overloaded Reduce the amount of equipment connected to these outlets Charge the battery for at least Due to age the battery does not 8 hours and recheck the battery Powerware 5110 UPS hold a full charge runtime does not provide
2. equipment Install Power management software provided with the UPS SO Ge 6 User s Manual 350 1500VA Indicators 1 On Off Push Button Test Switch One switch controls the power to your equipment and performs a self test to detect overload or undercharged conditions Turn on the UPS Press and hold the switch for more than one second and release the switch after the beep The UPS will start Turn off the UPS Press and hold the switch for more than one second and release the switch The UPS will shut down completely Perform Self Test The UPS will perform self test for about 4 5 seconds when the UPS is turned on and the utility power is present 1 2 Normal Mode Green LED Indicates the UPS is providing mains power to your equipment When the LED is blinking the UPS is providing power from the battery 3 Fault Red LED 4 When blinking LED could indicate an overload condition or that the battery should be replaced When the LED is always on it indicates a short or UPS fault For details please see Indicator Table 4 Battery Mode Yellow LED Indicates the UPS is providing battery power to your equipment User s Manual 350 1500VA Z 5 3 Battery Backup and Surge Protection Outlets These 3 Australian 10 Amp output receptacles 3 7 provide full time surge protection but also provide emergency battery backup power 6 3 Surge Protection Outlets These 3 Australian 10 Amp output receptacles provide full time pro
3. A 5 Battery connection required before use Connecting the Battery Principle shown below For detailed information how to connect please refer to battery replacement section Pull the top corner forward Slide down to remove the battery io remove che batiery Gower eover Connect the Battery cable Reinstall ine battery cover Installation and Operation The following steps explain how to connect and operate the Powerware 5110 UPS 1 Connect the UPS to a grounded power outlet Note It is recommended that the battery should be charged for minimum 8 hours to ensure full charge before placing the UPS in service 2 Plug your computer monitor or load to be protected into the Battery Backup amp Surge Protection outlets These outlets will provide emergency battery backup power during power outages as well as protection from surges and spikes Do NOT plug LASER PRINTERS into the Battery Backup outlets Do NOT plug ACCESSORY SURGE strips into the Battery Backup outlets 3 Plug your peripheral equipment or non critical loads printer scanner fax speaker etc into the Surge Protection outlets These outlets provide surge and spike protection only they will NOT provide battery backup power during a utility power failure Connect your computer to the UPS using USB cable provided With your equipment turned off switch on the UPS When the On Off LED light is illuminated turn on the connected
4. HxWxD 270x87x260 270x87x260 270x87x260 270x87x384 270x87x384 Unit Weight kg 5 6 8 12 12 5 Input Connection 1 8 metre line cord IEC to Australian 10Amp Plug Output Connection 6 Australian 10Amp Outlets 3 Battery Backup amp Surge Protection 3 Surge Protection only Operation Input Voltage Range 0 160Vac 0 300 VAC Output Voltage Range Nominal 23 to 25 On Battery Output Voltage Nominal 12 to 10 Frequency 50 Hz Lightning Surge Protection 476 joules Safety AS NZS62040 1 1 AS NZS60950 A Tick EMI AS NZS62040 2 AS NZSCISPR22 C Tick Transfer Time to Battery AC 2 6 msec typical Battery Type Sealed maintenance free lead acid battery Typical Backup Time 3 minutes at full rated load Internet Phone Fax Protection RJ11 Short Circuit Protection Circuit Breaker Communication Port USB Environmental Operation Temperature 0 C 40 C Operation Relative Humidity 0 to 95 non condensing Storage Temperature 15 C 50 C Software Powerware LanSafe Software is included free of charge Service Plans Optional Extended Warranty and On Site Changeover service plans available Battery Run Times in minutes Load VA Model 80 170 250 330 420 550 650 850 1000 1200 1350 1500 51100350A 31 12 7 4 51100500A 43 ly 11 51100700A 53 30 14 g 7 4 3 51101000A 80 64 28 20 15 12 8 51101500A 74 35 14 10 7 6 5 4 Due to continuing product improvement programs specifications subject to change without notice User s Manual 350 1500VA 13 E
5. N ENOPS 9 LED indicator Table s2c scuiccee racic Enne E NE E AS ETRE EEEE E E TEE AEA 9 LED Audible Alarmi Table sireadair RAE Aa AEE aara E E E AEE e ES 9 Battery replacement procedure sssssssrsssrnurrunnrsnnrnunnnunrnnnnnunnnunnnnnnnunnnunnnnnnnnn nunne 9 TrOUBDIESHOOUNG eccriene ie nant EER NA ERETO rE E eOr deena eee 12 SPESGCITICATON sa r EAA AEN EEN hi EREE DEENEN hue evened cox wand idatasd ieee tae aie 13 Service and SUpport scsi esc cede deia ce sces ninnisin r she ive ENA ARENA NEERA ARADAN cosas stedvesecenebanceevarcces 14 User s Manual 350 1500VA 3 Introduction The Powerware 5110 uninterruptible power system UPS filters the input line from line disturbances and protects your sensitive electronic equipment from five common power problems such as power failures power sags and power surges Features Processor controlled voltage regulation AVR Six outlets Three with surge and battery backup protection Three with surge protection only Data Line Internet fax modem DSL or telephone line surge protection Cold Start capability USB communication port User replaceable batteries Unit inspection Once you have received the Powerware 5110 UPS product you should remove and inspect the product for shipping damage If any damage is found please notify the carrier and your dealer Please keep the shipping carton and the packing foam in the event the product must be returned to the factory for service 4
6. Powerware 5110 UPS User s manual PE E T N Powerware 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced even extracts unless permission granted Every care has been taken to ensure the accuracy of the information contained in this manual but no liability can be accepted for any errors or omission The right to make design modifications is reserved User s Manual 350 1500VA Powerware 5110 UPS User s manual 1023922 Revision A Contents introduction soruan crete cate addins cnieG E A RER ENEAN 4 Feature S orure arra rE etnias IdE nET She cdae eE EE TNE E 4 UNIt INSPECTION iriiri n ro EEE EEEE EERE REDE E DEE E EEEE AEEA DEPEN 4 Safety INStCFUCHONS scarse ideapad GEARAN EAER ARE Gere tdamee das DENI SAPENAENE RENATA 5 Battery connection required before use s ssssssssusrusnnrnnnenunnnunnunnnnununnnrnnnnnunnnunnunnnnn 6 Connecting the Battery acento tees cats eetaniencts na o A Eei EE R E aa 6 Installation and Operation cevsisicccssccegeissecdies sc ceamedsca tia ceedawecee iieecsee dia Clediensecsinedstadawseeuewdees 6 Indicators isc ceedccesse decdeadeasstevers sieves eves Siaeeics qeedes ene bcee bead etnies siebeds chee eee ebed ected teed eeeceed 7 Indicator table ssc eecvcce ceeds ces seen ein cece new eiee RUNEN NE ESENE VEEN NEENA EEEREN ENSANSE ee 9 Status IMGICATORS ctecuestscaeth nano E aE OEE E weeds a NE SEEE A E E E EA
7. T N Powerware 14 User s Manual 350 1500VA
8. User s Manual 350 1500VA Safety Instructions ATTENTION Maintenance other than battery replacement must be performed by a qualified technician Failure to do so could result in an electrical shock Although the unit may be unplugged from utility power hazardous voltage still may be present through the battery 1 Place the Powerware 5110 UPS indoors in an area that has adequate airflow and is free of excessive dust Do NOT allow the UPS to be exposed to moisture rain excessive heat or direct sunlight 2 Use of the Powerware 5110 UPS product in life support applications where failure of this equipment can reasonably be expected to cause failure of life Support equipment or to significantly affect its safety or effectiveness is NOT recommended 3 Shut off the UPS and disconnect the input power cord from the wall outlet before replacing the battery 4 When replacing the battery use the same number and type of battery 5 Do NOT dispose of battery in a fire The battery may explode 6 Do NOT open or mutilate the battery They contain an electrolyte that is toxic and harmful to the skin and eyes 7 Proper disposal of the battery is required Please refer to your local laws regulations regarding battery disposal 8 Use tools with insulated handles to replace the battery to avoid personal injury Due to energy hazard please remove wristwatches and jewelry such as rings when replacing battery User s Manual 350 1500V
9. expected runtime Battery might need to be changed look at battery replacement Refer to the Indicator Table Powerware 5110 UPS is making a continuous sound and the Overload indictor is lit The Powerware 5110 UPS will turn off when the battery has been depleted during the failure of utility Connected equipment lose power Allow UPS to re charge power while connected to before continuing use of the UPS the Powerware 5110 UPS Ensure that the equipment you want to stay powered during a failure of utility power is plugged into the Battery Backup amp Surge Protection outlets The Battery Backup amp Surge Protection outlets are overloaded The Powerware 5110 UPS has depleted the battery Connected equipment is connected to the wrong outlet Please call your local Powerware representative for further troubleshooting The Powerware 5110 UPS may be faulty Service and Support For questions and or problems please call your local distributor or the help desk and ask for a UPS technical representative Powerware National Service Centre 1300 303 059 Please have the following information ready Model number and Serial number Symptoms of failure or problem Customer contact information For additional information please visit us online www powerware com au 12 User s Manual 350 1500VA Specification Capacity 350VA 210W 500VA 300W 700VA 420W 1000VA 600W 1500VA 900W Dimensions mm
10. tection from surge and spike 7 Phone Modem ADSL Protection Built in RJ11 jacks protect the internet phone or fax line from surges Connect the line in from the wall into the jack named In and connect 6 the phone modem ADSL box to the jack named Out 5 8 USB Communication Port The provided LanSafe monitoring and shutdown software can be automatically configured to save the files and shut down your computer in the event of a prolonged power outage 10 9 Circuit Breaker 9 The button will protrude when the overload condition occurs The UPS will switch off of utility power If the button protrudes disconnect some non essential equipment and reset the circuit breaker by pushing the button inward 10 Power Connector 10 Amp IEC to 10 Amp Australian input lead provided 8 User s Manual 350 1500VA Indicator Table Status Indicators The UPS provides both visual and audible status indicators Visual indicators consist of three LEDs to represent the following conditions On utility power operation On battery power operation UPS fault alarm LED Indicator Table On Utility AC mode Green Lighting On Battery backup mode Yellow Lighting Fault Output Short Red Lighting Overload Check Battery Red Flashing LED Audible Alarm Table On Battery backup mode Sounding every 5 seconds Replace Battery Sounding three beeps every 30 seconds Fault or output short circuit Continuous sounding

Download Pdf Manuals

image

Related Search

Related Contents

Uncle Milton Remote Control Tarantula  DS-9000/DS-9100/DS-9600 Series DVR USER`S MANUAL Version  Proel DHPA140  Installations-Menü  Programmier-Handbuch mx-16 HoTT.1.de  Case Logic Basic Laptop Case 15.4" with extra compartment  Platform Notes: Ultra 450 Workstation and Ultra Enterprise 450 Server  Descargar ficha técnica    Livres pour enfants de Roald Dahl : essai de thématique (Les)  