Home

Wiser home controller 2 user manual

image

Contents

1. C Bus Wiser Home Controller 2 WHC2 5918 FEO CE User s Manual Copyright Schneider Electric Australia Pty Ltd 2015 Allrights reserved This material is copyright under Australian and international laws Except as permitted under the relevant law no part of this work may be reproduced by any process without prior written permission of and acknowledgement to Schneider Electric Australia Pty Ltd Clipsal and C Bus are registered trademarks of Schneider Electric Australia Pty Ltd The information in this manual is provided in good faith Schneider Electric Australia Pty Ltd has endeavoured to ensure the relevance and accuracy of the information but it assumes no responsibility for any loss incurred as a result of its use Schneider Electric Australia does not warrant that the information is fit for any particular purpose nor does it endorse its use in applications that are critical to the health or life of any human being Schneider Electric Australia reserves the right to update the information at any time without notice Version 1 0 Release date February 2015 Wiser Home Controller 2 User s Manual Contents 1 0 2 0 3 0 4 0 Introduction 1 1 About this Document 1 2 Version 1 3 Notes Hardware Overview 2 1 Home Controller Components 2 2 Connectors and Indicators Using the User Interface 3 1 Graphical User Interface 3 2 Concepts 3 3 Basic Guidelines and Use 3 3 1 Opening the Us
2. Remote connection Remote URL IP Address The static URL IP Address or Dynamic DNS URL you use to connect to your Wiser from outside your home Example www mywiser com Port Address The port number that is open to receive a remote connection to your Wiser normally set to port 80 Navigation The Wiser 2 Home Controller User Interface will vary depending on the Widgets used A typical page is shown below 25 4 7 4 8 Wiser Home Controller 2 User s Manual all Telstra 10 13 AM Po Lighting AR Admin Home Main Light Bedside Lamp Master Bedroom i Master Bedroom FUNCTIONS Lighting Kitchen Light HVAC Kitchen Scenes Fans Security Power WE LOCATIONS Master Bedroom Kitchen Kids Bedroom Lounge ORE SETTINGS System Utilities Edit Scenes f Log out Widgets The Widgets are used in much the same way as when accessing the Wiser 2 Home Controller from a web browser for which the details have been given separately The general look of the widgets across all clients is the same On smart phones the user will be using fingers or a stylus to navigate around the application Menu In tablets the left panel with the options for Functions Locations etc is always displayed but in mobile phones the user has to press the menu button or slide out the screen Below is the image of the left panel menu and also of the Menu button in mobile phones 26 Wiser Hom
3. Dial The needle will show the following for each dial Gauge siindicates o Current rate of consumption in kW CO Accumulated consumption this day in kWh kgCO Weekly Weekly Accumulated consumption this week in kWh kgCO Monthly Accumulated consumption this month in kWh kgCO The colour ring on the dial should be divided into green amber and red thirds as shown below 44 Wiser Home Controller 2 User s Manual The dial mask should follow the needle position The green orange and red segments should be defined by the percentages shown in the widget parameters In Gauge Number Inside each gauge there is an indicator displaying the current value and units This should be as follows Gauge Legend Current rate of consumption kW kgCO Accumulated consumption this day kWh kgCO Weekly Weekly 0 Accumulated consumption this week kWh kgCO Monthly Accumulated consumption this month kWh kgCO Under Gauge Legend Under each gauge there should be a legend The legend can have up to three lines of text below which will be 1 Gauge symbol with description of what the dial is currently showing 2 Estimated consumption for this period 3 Consumption for previous period if available otherwise no legend should be displayed 45 Wiser Home Controller 2 User s Manual FULL LEE FEE a Fy 3 98 0 kW i Rate of Consumption Estimated this hour 3 00kWh KLUDE FEE
4. Wiser Home Controller 2 User s Manual Totals use a range centred graph where e Values above the zero line are displayed in yellow e Values below the zero line are displayed in green Dials shown on the graph use the same configuration as the Power Meter Totals widget THIS WEEK THIS MONTH 0 0 Hours Days Weeks Months 7 Oe Ooo 5 Tuesday Wednesday Thursday Friday Saturday Sunday Monday Logic Widgets Logic Widgets are used by the Wiser 2 logic engine These are used to provide customised behaviour for the Wiser 2 Home Controller Their usage will be unique for each project Typical uses might include Setting asystem mode such as away from home or night time Displaying system data or messages e e e Setting the date or time for some event to occur e Enabling or disabling some system function User System IO Integer The User System IO Integer widget is used to select an integer whole number for controlling some aspect of the C Bus system The details of the usage will depend on the project System IO widgets have a default icon og User SyslO Integer 16 51 5 4 2 5 4 3 5 4 4 Wiser Home Controller 2 User s Manual All Ul clients will provide a method to enter the desired integer value within the defined range and when the desired value is set press Save to update User System IO Real The User System IO Real widget is used to select a real value number with decimal point for c
5. 29 30 30 31 31 32 32 33 33 33 33 34 35 35 39 41 42 43 48 51 51 52 52 52 53 Wiser Home Controller 2 User s Manual 5 4 6 User System IO Time 5 5 Other Widgets 5 5 1 Web Camera 5 6 ZigBee Widgets 5 6 1 ZigBee Lighting Endpoints 5 6 2 ZigBee Lighting Groups 5 6 3 ZigBee Lighting Scenes 5 Favourites 6 0 Terms 53 53 53 54 55 56 57 I 59 1 0 1 1 1 2 1 3 Wiser Home Controller 2 User s Manual Introduction About this Document The Wiser 2 Home Controller allows you to access your C Bus using a graphical user interface sometimes referred to as the Wiser 2 UI The Wiser 2 Home Controller arrives with a sample project loaded and the user interface accessible from your local home network With certain options set you can also access the Wiser 2 UI from anywhere using the Internet Using the Wiser 2 Home Controller you can e control equipment such as IP cameras C Bus devices and non C Bus wired and wireless equipment on the home LAN schedule events in the home create and store scenes on board customise a C Bus system using the on board Logic Engine monitor the home environment including C Bus and security systems control ZigBee products such as Ulti ZigBee Dimmer Relay Groups and Curtains connect to Flash Android HDMI Android Mobile and iOS clients to access the user interface remotely connect to your Wiser 2 using Flash Android Mobile and iOS clients to access the us
6. CONNECTION WAN Address Port Number SL Security Based on the connection you want to connect with enter the relevant details either in the Remote Connection section or the Local Connection section In the Local Connection section enter the IP Address for the Wiser 2 Home Controller In the Remote Connection section enter the WAN IP Address URL for the Wiser 2 Home Controller if there is one It should be noted that if you are connecting from the WAN side you will need to have enabled the Projector Control feature to enable external access to the Wiser 2 Home Controller 24 4 6 Wiser Home Controller 2 User s Manual Enter the Username and Password based on the profile you want to connect with These will be stored in the unit and not requested in future unless you select to logout and clear it If you are connecting from the WAN side then SSL Security option is advised to be turned on so that the communication between the mobile client and the Wiser 2 Home Controller is encrypted There is a Help button provided on the login page to give more details about the fields user needs to enter on the login page as shown below Uk E ee gt A Wiser Settings Help This is what you need to set up this app with you Wiser Username and password The username and password you use to connect to your Wiser Local Connection Local IP Address gt The IP Address of your Wiser unit on the local network Example 192 168 2 1
7. Home Controller 2 User s Manual Favourites are supported on all clients where the Flash iOS and Android mobile clients have a similar mechanism to add remove from Favourites In the Android HDMI client the user can use the red button F2 on the keyboard to add remove from Favourites Favourites are client and profile dependent so each client and profile combination can have their respective favourites allowing multiple users to have what is important for them on the Favourites page 98 Wiser Home Controller 2 User s Manual Ul CNI Customer s Modem Default Gateway DHCP DNS Flash IP Address LAN NTP Projector WAN Wiser 2 Home Controller The user interface that customers will use to control their C Bus and ZigBee products C Bus Network Interface The CNI handles Ethernet to C Bus communication and provides electrical isolation between the networks The hardware component connecting the Wiser 2 Home Controller to the Internet A network node for example a router which serves as an access point to another network Dynamic Host Configuration Protocol A protocol that assigns IP addresses to devices e g computer printer on a network Domain Name System A service that translates easily memorised domain names to numerical IP addresses Adobe Flash previously called Shockwave Flash and Macromedia Flash is a method for adding animation and interactivity to web pages Internet Proto
8. User name admin e Password admin The user name can not be changed It is recommended that the password be changed for security If you change the password it may be a good idea to write it below Password To change the password 1 Click on the Project menu in PICED 2 Click on the Edit Profiles option 3 Edit the Admin profile 4 Enter the new password 5 Click OK to save the changes There is a concept of Profiles in Wiser 2 Home Controller which was not present in the earlier version of Wiser Home Controller Profiles allow users to have different user names and passwords each with respective rights such as administrative rights All rights Edit Widgets Edit Schedules Edit Scenes etc This enables the Administrator to create profiles allowing users to view and edit only a few things To add edit profiles Click on the Project menu in PICED Click on the Edit Profiles option Press the Add button to add a profile Inthe window that appears enter Profile Name Username and Password Assign the rights you want the user to have remember administrator rights means the user has all rights 6 Click OK to save the changes oR WD Similarly created profiles can be edited using the same Edit Profiles option Sequence of Operations Power On and Initialisation Switch on the Wiser 2 Home Controller before accessing the Wiser 2 user interface Allow time for the controller to establish connection with the C B
9. not require a Save By default the options are disabled Changing remote access settings will prevent certain access modes from working Be sure you know what the effects of a change will be before you change the current setting Some changes will cause a reboot and could interrupt activity on your network Toolkit control Projector control Project update Toolkit Control This feature is intended to allow installers to use C Bus Toolkit to manage and reprogram a C Bus network remotely when they need to 16 3 9 2 Wiser Home Controller 2 User s Manual It is important to make sure to disable toolkit control after use leaving it open allows anyone to manipulate your C Bus network Projector Control allows the web user interface to be accessed via a web browser and or a projector running on a device like a laptop or other mobile device This feature is intended to allow a user or installer to interact with their C Bus network when outside of their home by using the Internet This option can safely be left enabled because there is authentication of the web browser or projector connecting to the Wiser 2 unit Project Update allows a PICED project to be uploaded to theWiser 2 Home Controller over the Internet This means that anyone on the Internet if they knew the Internet address of your device can connect to the device and transfer a project to the unit and or retrieve a project from the unit It is important to make s
10. It is generally used with a ZigBee relay output but can also be used with a dimmer When used with a dimmer output only the Off and On levels are used The appearance will depend on the icon selected The icon and Widget Label will show whether the load is on when indicating it by the colour green The ON OFF button will toggle the state between on and off ZigBee Endpoint Dimmer The ZigBee Endpoint Dimmer widget is used for level control of a load from 0 to 100 It is generally used with a ZigBee dimmer output The appearance will depend on the icon selected The icon and widget label will show whether the load is ON indicated by the color Green The and buttons can be used to increase decrease the current set level and they will use the defined ramp rate to reach the desired level When turning ON the last set level will be recalled The ON OFF will toggle the state between on and off ZigBee Endpoint Curtain Controller The ZigBee Endpoint Curtain Controller widget is used for opening and closing electric curtains blinds and shutters The general appearance of the widget is fixed The button labels and the name of the controlled device can be set The widget has a three button control where the first button is for Up Open second button is for Stop and the third button is for Down Close 95 5 6 2 Wiser Home Controller 2 User s Manual ZigBee Lighting Groups ZigBee Group Relay The ZigBee Group Relay wid
11. Phone Tablet The process for getting the Mobile Phone Application using your iOS phone tablet is 1 Search for the Wiser 2 application from Schneider Electric in the App Store 2 Download and install the application on your mobile tablet Using an Android Phone Tablet The process for getting the Mobile Phone Application using your Android phone tablet is 1 Search for the Wiser 2 application from Schneider Electric in the Google Play Store 2 Download and install the application on your mobile tablet Installing the Application If you downloaded the Application using a mobile phone or tablet you will automatically be prompted to install it Running the Application To run the Wiser 2 application click on the Wiser 2 icon in both iOS and Android 21 Wiser Home Controller 2 User s Manual Wiser2 iOS The following Welcome to Wiser 2 screen will be displayed in the iOS application Q wisen alu 1 ie or ye Let s Start Pressing on the Let s Start button will display the following screen Connect Use SSL for Remote Connection ON Em 22 Wiser Home Controller 2 User s Manual Based on the connection you want to connect with enter the relevant details either in the WAN URL field or the Lan IP field In the Lan IP field enter the LAN IP Address for the Wiser 2 Home Controller In the WAN URL field enter the WAN IP address URL for the Wiser 2 Home Controller if there is one It should be noted
12. Status 31 Timer 32 Locations 11 Selecting 14 Logic 51 Long Press 28 Measurement Power Meter 43 48 MinderPro 41 Mobile Phone Application 21 Compatibility 21 Getting Application 21 Installing 21 Menu 26 Navigating 25 Requirements 21 Running 21 Using 25 Wiser Home Controller 2 User s Manual Homesafe 39 MinderPro 41 Settings 15 Setup 18 Setup 18 Short Press 28 Mobile Phone Shutter Control 30 Widgets 26 Start up 13 MRA 34 35 Status 8 14 31 Multi room Audio 34 35 System lO 51 N T Navigation 14 Terminology 28 Notes 6 Terms 59 Time 17 p Timer 32 ToolKit 15 16 Pages 11 Tools 11 15 Password 15 Power Meter 43 48 U Power up 13 Preset 31 32 User Interface 12 Profiles User System IO 51 Editing 18 Boolean 52 Project Update 16 Date 53 Projector 16 Integer 91 Pulse Power Meter 43 48 Real 52 String 52 Time 53 R Using 12 Relay 28 30 Zigbee Endpoint 55 V Zigbee Group 56 Remote Access 16 Version 6 S W scene Warnings Local Control 33 ToolKit 195 Trigger 33 Unable to connect 15 Zigbee Lighting 57 Web Camera 53 Scenes Widget 11 Editing 18 Widgets Schedules C Bus 28 Editing 18 Controlling 28 Scroll Pad 11 Icons 28 Security Logic 51 Mobile Phone 26 Z Zigbee Endpoint Curtain Controller 55 Dimmer 55 Zigbee Endpoint Relay 55 Zigbee Group Curtain Controller 56 Dimmer 56 Relay 56 Zigbee Lighting Scene 5 7 Wiser Home Controller 2 User s Manual ICLIPSAL by Schneider Electric Produc
13. an be accessed at home or remotely over the Internet 2 2 Connectors and Indicators The connectors and indicators on the Wiser 2 Home Controller are shown below Wiser 2 Home Controller Router Wiser Home Controller 2 User s Manual Back Panel Front Panel Ethernet LAN RJ45 Socket Connector also supports 802 af POE ZigBee UZI Port under top cover LED Indicators The operation of the LEDs is shown in the table below Symbol LED Name Wiser Home Controller 2 User s Manual Power On when power is applied to the unit using the supplied AC DC power supply or Power over Ethernet PoE when connected to the appropriate power source 802 af PoE device C Bus Yellow Green Red Initialising e g during boot up C Bus Green Good connection to C Bus updated every 30 seconds Red C Bus connection not functional updated every 30 seconds Off LEDs disabled or C Bus not enabled F Wi Fi Green Connected Yellow Connecting authenticating obtaining IP address Red Blocked failed suspended disconnected disconnecting Off LEDs disabled or Wi Fi not enabled MRA Ripple Green Matrix switcher connected database ready not cataloguing Orange Matrix switcher connected database scanning cataloguing music Red Matrix switcher not connected due to invalid TCP address network error or USB plugged in to matrix switcher Off LEDs disabled or Ripple not enabled ZigBee Yellow Green Red I
14. ange A series of options will appear which will allow you to change various aspects of the schedule e Type this allows the type of schedule to be selected See the details below e Day of Week this allows you to select which days ofthe week the schedule is to occur on e Day of Month this allows you to select which days of the month the schedule is to occur on For a Repeat Days Schedule see below the repeat interval is selected using the Day of Month page e Time this allows you to select the schedule time or range of times Month this allows you to select which months the schedule is to occur on e Year this allows you to select which years the schedule is to occur on Schedule Type The time ofthe Schedule can be selected from Fixed Time this will result in the schedule being executed at a fixed time Sunrise this will result in the schedule being executed at sunrise plus or minus an offset time Sunset this will result in the schedule being executed at sunset plus or minus an offset time Repeat this will result in the schedule being executed at a regular interval between a start time and a finish time Random this will result in the schedule being executed at a random time between a start time and a finish time The day of a schedule can be selected from Selected Days this will result in the schedule occurring on the days selected using Day of Week Day of Month Month and Year Repeat Days this will result in the
15. ata e Dials should use the percentage segments as per the widgets configuration Generators e Generator graphs should follow the same rules as power meters The graph line can be shown in green e Dials should use the percentage segments as per the widget s configuration e Dials should use the same colour sequence as the generator widget Graphs also show historical data for the past 24 hours 7 days 4 weeks 12 months Power Meter Totals The Power Meter Totals Widget is used for monitoring the total power usage They display the power level from all measurement or pulse power meters The totals widget differs from the other widgets as it can display negative values In the event more power is generated than consumed then a negative value will appear in the data The dial will display from a negative to a positive value where the zero point is calculated from the minimum and maximum positions 48 Wiser Home Controller 2 User s Manual The totals dial will show green for generation and yellow for consumption Data provided from the system is negative for power generation and positive for consumption Note This only applies to the totals widget All other data whether generator or power meter are positive values Needle amp Dial The needle will show the following for each dial Gauge sindicates o In Gauge Number Inside each gauge there is an indicator displaying the current value and the units Th
16. ccess the Wiser 2 Home Controller and hence the term click is used referring to a mouse click If you are using a device with a touch screen the term click will mean touching the screen Wiser Home Controller 2 User s Manual 2 0 Hardware Overview 2 1 Home Controller Components For details of installation of the Wiser 2 Home Controller refer to the Wiser 2 Home Controller Installation Instructions and the Wiser 2 Home Controller Setup Sheet a N Ar AA Fo ne i The Wiser 2 Home Controller has the following hardware components Wiser 2 Home Controller AC DC Power Supply C Bus Connector and Cover Ethernet Patch Cable Battery not shown accessible from the door on the bottom of the unit The Wiser 2 Home Controller does not require a separate CNI for C Bus connection as it has an on board CNI and a C Bus port for the C Bus cable connection In case the user still requires another CNI due to the fact their Wiser 2 Home Controller and C Bus network are not close to each other then that can be done with a separate CNI but this is not provided with the Wiser 2 Home Controller The installer uses PICED and C Bus Toolkit software to create a unique project for the customer s home The project is transferred to the Wiser 2 Home Controller It is then ready to be used with the Wiser 2 User Interface Wiser 2 Ul The installer provides the home owner with the IP address and security codes needed to access the project The Wiser 2 Ul c
17. col Address A numerical label assigned to each device e g computer printer participating in a computer network Local Area Network A computer network that interconnects computers within a limited area such as a home school or office building Network Time Protocol A protocol for clock synchronisation between computer systems over a network Software used to display the Wiser 2 Home Controller user interface without the need for a web browser supporting Flash Wide Area Network A computer network that interconnects computers across a broad area such as metropolitan regional national or international boundaries The unit that provides the connection from the customer s equipment to C Bus and IP devices 59 Index A About 6 Air Conditioning 42 B Bellpress 29 C C Bus Connection 14 Date 17 Time 17 Widgets 28 C Bus ToolKit 16 Climate 42 Concepts 11 59 Connection 14 Curtain Control 29 Curtain Controller Zigbee Endpoint 55 Zigbee Group 56 D Date 17 Dimmer Zigbee Endpoint 55 Zigbee Group 56 Dimming 28 Editing Profiles 18 Scenes 18 Schedules 18 Enable Control 33 Preset 32 Energy 48 48 Error Wiser Home Controller 2 User s Manual Unable to connect 15 Fan Controller 33 Function Groups 11 Selecting 14 H Home Controller 11 Homesafe 39 HVAC 42 Icons 14 28 Images 28 Installation 8 L LEDs 8 Lighting Bellpress 29 Dimming 28 Preset 31 Relay 28 30
18. e Controller 2 User s Manual Menu Button The menu allows the following actions to be performed Home Select the Home option to view the Favourites or to get access to the Stats page Functions Allows the user to view and control the widgets based on the selected function Locations Allows the user to view and control the widgets based on the selected location Settings Allows the user to Edit Scenes change or view the C Bus Date and Time etc Logout Allows the user to log out of the application 27 Wiser Home Controller 2 User s Manual 5 0 Widgets 5 1 5 2 5 3 5 3 1 5 3 2 Press click Short Press The term short press is used to describe clicking the mouse button and then releasing within about 1 2 second If you are using a touch screen device you will be pressing the screen with your finger rather than using a mouse In this document it is assumed you are using a mouse Long Press The term ong press is used to describe clicking the mouse button and then holding for more than 1 2 second before releasing Icons There are many icons available for use with the user interface and can be selected for use with the widgets Some of the icons available are shown below Light Bulb Bell Press Security Q C Bus Widgets C Bus Widgets are used to monitor and control C Bus devices including relays dimmers sensors security panels media devices and air conditioning systems General Li
19. e can be adjusted up louder or down quieter using the Slider The mute button adjacent to the volume slider allows you to switch the sound off and on The source can be selected from the list of available sources by pressing the arrow icon displayed adjacent to the source in play The selected source will be highlighted By clicking on the ES button you can control features which are needed less often bass and treble control The respective sliders will allow the bass and treble levels to be adjusted 34 5 3 16 5 3 17 Wiser Home Controller 2 User s Manual Treble Clicking on the back button will take you back to the volume and source selection page Media Transport The Media Transport Widget is used for controlling an audio video system The widget allows you to activate any of the following functions of an audio video device Play Pause Stop Next Previous Rewind Fast Forward Record The appearance of the Widget will vary depending on which controls have been selected for use with the Widget The widget has a default icon Play assigned to it and this cannot be changed A Short Press on an icon will activate that function MRA V3 Zone Widget The MRA V3 Zone Widget is used for controlling a C Bus Multi Room Audio system MRA version 3 35 Wiser Home Controller 2 User s Manual The appearance of the Widget will depend on the source type and the controls selected The images below are examples of how
20. e scene and save them to the Wiser 2 Home Controller The feature does not allow users to add groups or add scenes through this Section In order to add more scenes or groups to a scene the project needs to be modified in PICED and transferred to the Wiser 2 Home Controller Schedule Edit The user can edit all the unlocked schedules from this option The option gives the user the ability to modify the parameters of the schedule and save them to the Wiser 2 Home Controller The feature does not allow users to add events or schedules through this section In order to modify the events of a schedule or add a new schedule the project needs to be modified in PICED and transferred to the Wiser 2 Home Controller Setup This option allows the user to select the language they want to see the Ul in allows the user to edit the network settings by enabling disabling DHCP enabling disabling WiFi NTP Settings etc The user can also enable disable SAMBA share through this option System Utilities e Remote Access select the options for using the Wiser from a remote location e C Bus Date amp Time set the Wiser Date and Time this will be sent to C Bus Remote Access The remote access settings are available on the Wiser 2 Ul Settings page under System Utilities The option lets you enable or disable access to your system from the Internet for C Bus ToolKit projectors or project updates The options under Remote Access take effect immediately and do
21. e within the defined range and when the desired value is entered press Save to update User System IO Time The User System IO Time widget is used to select a time for controlling some aspect of the C Bus system The details of the usage will depend on the project System IO widgets have a default icon 11 59 59 All Ul clients will provide a method to enter the desired Time within the defined range and when the desired value is entered press Save to update Other Widgets Web Camera The Web Camera Widget is used for displaying the video from a web camera Clicking on the web camera picture displays the widget in an expanded view Clicking the cross button would close the expanded view 53 Wiser Home Controller 2 User s Manual Camera 2 O MELET ec Photo library Users can use the Take a photo button to take photos being displayed from the web camera Photo library as shown in the below picture will show all the clicked photos These photos can also be saved on the hard drive Library Camera 2 lg F i Tue Nov 12 2013 Tue Nov 12 2013 Tue Nov 12 2013 05 24 00 AM 05 24 00 AM 05 24 00 AM 5 6 ZigBee Widgets ZigBee Widgets are used to monitor and control ZigBee devices including relays dimmers curtain controllers and scenes 54 5 6 1 Wiser Home Controller 2 User s Manual ZigBee Lighting Endpoints ZigBee Endpoint Relay The ZigBee Endpoint Relay widget is used for on off control of a load
22. er interface Examples of equipment you might access with Wiser 2 Home Controller include lighting HVAC curtains cameras sprinkler systems power monitoring Ulti ZigBee multi room audio and security controls Purpose The Wiser 2 User s Manual is provided to familiarise you with some of the features of the interface and to help you to use it more effectively Some of the illustrations in this document might not look exactly like what you see on your screen as with different clients the look can be slightly different due to limitations of the client For the most part the look will be consistent across all clients This is because there are several different skin designs and there are many different devices available for accessing your Wiser 2 Home Controller If you are using PICED software you can access the skin help or manual using the Help drop down menu Version Version 1 0 The current versions of the Wiser 2 Help file and the Wiser 2 Home Controller User s Manual are included with the PICED software Copyright 2015 Schneider Electric Australia Pty Ltd Notes Each Wiser 2 Home Controller project is unique The examples in this document are provided to demonstrate the general concepts The usage and appearance of your Wiser 2 Home Controller user interface may be different to that shown here Wiser Home Controller 2 User s Manual This document generally assumes that a web browser and a mouse are being used to a
23. er Interface 3 3 2 Sequence of Operations 3 3 3 Navigation 3 4 Status Information 3 4 1 Connection 3 4 2 Warnings 3 5 Settings 3 5 1 Remote Access 3 5 2 C Bus Date and Time 3 5 3 Setup 3 5 4 Profiles 3 5 5 Edit Scenes 3 5 6 Edit Schedules Using the Mobile Phone Application 4 1 General 4 2 Requirements 4 3 Getting the Application 4 4 Installing the Application 4 5 Running the Application 4 6 Navigation oOo oOo 0 0 0 OH 11 11 12 12 13 14 14 14 15 15 16 17 18 18 18 18 21 21 21 21 21 21 29 5 0 4 7 Widgets 4 8 Menu Widgets 9 1 9 2 9 3 9 4 Wiser Home Controller 2 User s Manual Press click Icons C Bus Widgets 9 3 1 9 3 2 9 3 3 9 3 4 9 3 9 9 3 6 9 3 9 3 8 9 3 9 5 3 10 9 3 11 9 3 12 9 3 19 0 3 14 9 3 15 5 3 16 5 3 17 9 3 18 9 3 19 9 3 20 9 3 21 5 3 22 General Lighting Relay General Lighting Dimmer Bellpress Curtain Control Two State Lighting Relay Shutter Relay Lighting Preset Lighting Status General Lighting Timer Enable Preset Two State Enable Fan Controller Scene Trigger Local Scene Controller Multi Room Audio Zone Media Transport MRA V3 Zone Widget Homesafe Panel MinderPro Panel Climate Control Power Meter Power Meter Totals Logic Widgets 5 4 1 5 4 2 5 4 3 5 4 4 5 4 5 User System IO Integer User System IO Real User System IO String User System IO Boolean User System IO Date 26 26 28 28 28 28 28 28 29
24. ese options will be available A projector is a software application which can display the Wiser 2 Home Controller User Interface and allow the user to view and interact with the Wiser 2 Home Controller It can run like a desktop application on your PC Basic Guidelines and Use Opening the User Interface Control of the Wiser 2 Home Controller is done via a web based user interface usually a web browser This could be a web browser connected to the Local Area Network LAN or connected remotely via the Internet It is also possible to control the Wiser 2 Home Controller via the Wiser 2 application running on Android or iOS mobiles and tablets The user interface can also be controlled using a HDMI client such as a TV by connecting the HDMI cable between the TV and Wiser 2 Home Controller port provided at the back of the unit To display the Wiser 2 Home Controller user interface on a web browser which is connected to the LAN enter the following URL in the web browser http 192 168 2 1 or the address as configured during installation Note You will need to use the actual IP Address of the Wiser 2 Home Controller in the above URL This will be provided by your installer It may be a good idea to write it below Wiser 2 Home Controller IP Address 12 3 3 2 Wiser Home Controller 2 User s Manual When you first use the Wiser 2 Home Controller you will be prompted for a user name and password The default values are e
25. ether the scene is set or not indicated by the colour green The name of the scene is displayed adjacent to the icon a Remote Scene Sam START A Short Press on the START button will set the scene Local Scene Controller The Scene Controller Widget is used for setting a scene This allows many lights to be set to pre determined levels all at once and also allows the levels to be nudged up or down The appearance will depend on the icon selected The icon widget Label and ON will show whether 33 5 3 15 Wiser Home Controller 2 User s Manual the scene is set or not indicated by the colour green The name of the scene is displayed adjacent to the icon a Local Scene Sample START A Short Press on the START button will set the scene Clicking on the up and down arrows will nudge the level of the scene by a small amount This is useful if the lighting level is not quite right and needs to be adjusted to be a bit brighter or dimmer When a scene is nudged upwards all of the lights in the scene will brighten by the same percentage except for those already at 100 When a scene is nudged downwards all of the lights in the scene will dim by the same percentage except for those already at 1 Multi Room Audio Zone The MRA Zone Widget is used for controlling a C Bus Multi Room Audio MRA system The widget allows you to e Select a music source e Adjust the volume e Adjust the bass and treble levels The volum
26. etwork e e e e Warnings C Bus When the C Bus ToolKit is connected to the Wiser 2 Home Controller where the controller is using a remote CNI connection instead of a direct CNI connection the following warning message would be displayed C Bus Connection in Transparent Mode User interface actions will not be processed In the above case you will be unable to use theWiser 2 Home Controller to control C Bus during this time ZigBee ZigBee Interface Updating Firmware Performing ZigBee Device Discovery Settings The Settings section allows the user to control the profiles network settings ethernet settings C Bus date time etc This section is accessible only if the user has rights to it All the options under Settings are not available in all Clients they are available in Flash and Android HDMI but only a subset of them are available in Android and iOS mobile and tablet applications The following sections come under Settings Profiles This option displays all the Profiles part of the Project User can change the Username Password and Profile permissions for all profiles depending on their rights except for the Administrator Profile For the Administrator profile which is the default profile only Password can be changed 15 3 9 1 Wiser Home Controller 2 User s Manual Scene Edit The user can edit all the unlocked scenes from this option The option gives the user the ability to modify the parameters of th
27. g Preset The Lighting Preset widget is used for setting a load to a preset level from 0 to 100 The appearance will depend on the icon selected The icon widget label and Preset Level will show whether the load is at the Preset level indicated by the color green A Short Press on the Preset Level panel will set the load to the preset level Lighting Status The Lighting Status widget shows when a load is on It is not used for controlling the load The status will be shown by displaying the level 0 100 31 5 3 9 5 3 10 Wiser Home Controller 2 User s Manual Icon and Widget Label Status The appearance will depend on the icon selected The icon and widget label will show whether the load is on or not indicated by the colour green The icon and widget label will indicate ON if the level is anything between 1 100 O status Sample Level Status The level of the load will be displayed 0 100 Any press on the widget will be ignored General Lighting Timer The General Lighting Timer widget is used for switching on a load for a specific period The appearance will depend on the icon selected The icon and widget label will show whether the timer is on or off indicated by the colour green Q Timer Sample amp 0 10 A press on the Start button will start the timer and set the target level A second press will stop the timer and set the return level instantaneously If left running the return level
28. get is used for on off control of a group of relay widgets each connected to a load It is generally used with a ZigBee relay output but can also be used with a dimmer When used with a dimmer output only the Off and On levels are used The status of the devices in the group will be based on the status of the representative endpoint of the group when controlling the ZigBee Group Relay widget The appearance will depend on the icon selected The icon and Widget Label will show whether the load is on when indicating it by the colour green The ON OFF button will toggle the state between on and off ZigBee Group Dimmer The ZigBee Group Dimmer widget is used for level control of a load from 0 to 100 It is generally used with a ZigBee dimmer output The appearance will depend on the icon selected The icon and widget label will show whether the load is ON indicated by the color Green The and buttons can be used to increase decrease the current set level and they will use the defined ramp rate to reach the desired level When turning ON the last set level will be recalled The status of the devices in the group will be based on the status of the representative endpoint of the group when controlling the ZgBee Group Dimmer widget The ON OFF will toggle the state between on and off ZigBee Group Curtain Controller The ZigBee Group Curtain Controller widget is used for opening and closing electric curtains blinds and shutters T
29. ghting Relay The General Lighting Relay widget is used for on off control of a load The appearance will depend on the icon selected The icon will show whether the load is on indicated by the colour green The ON OFF button will toggle the state between on and off General Lighting Dimmer The General Lighting Dimmer widget is used for level control of a load from 0 to 100 The appearance will depend on the icon selected The icon and widget label will show whether the load is ON indicated by the color green The Level slider can be used to increase decrease the current set level Ramp Rate is associated with the ON OFF button thus if Ramp rate is applied 28 9 3 3 5 3 4 Wiser Home Controller 2 User s Manual then ON OFF would use that to reach the desired level moving the level slider manually will not use defined Ramp rate and will set the level instantly The ON OFF button will toggle the state between on and off The level slider will be used to dim up and down Bellpress The Bellpress widget is used for momentary activation of a load for example a doorbell The appearance will depend on the icon selected The icon widget label Press button will show whether the load is on or off indicated by green A press click on the icon will change the state to on Releasing will change the state back to off Curtain Control The Curtain Controller widget is used for opening and closing electric curtains blind
30. he general appearance of the widget is fixed The button labels and the name of the controlled device can be set The widget has a three button control where the first button is for Up Open second button is for Stop and the third button is for Down Close This widget will be able to control a group of curtains 56 9 6 3 5 7 Wiser Home Controller 2 User s Manual ZigBee Lighting Scenes ZigBee Group Scene The ZigBee Group Scene Widget is used for setting a scene This allows many lights and curtains to be set to pre determined levels all at once The appearance will depend on the icon selected The icon widget Label and ON will show whether the scene is set or not indicated by the colour green The name of the scene is displayed adjacent to the icon A Short Press on the START button will set the scene Favourites Favourites are a new feature provided with the Wiser 2 Home Controller whereby a user can select the widgets that they will be most commonly using on a regular basis All the selected widgets will be displayed on the Favourites page and the user can access them from one place rather than looking for them under different functions locations Widget functionality does not change when viewed from the Favourites page Selecting the Star will add the widget in Favorites To remove from favorites de select Bedside Lamp the same star icon The favourites can be accessed from Home gt Favourites 57 Wiser
31. i a 3 98 kW 0 9 Rate of Consumption Estimated this hour 3 00 kWh Consumed last hour 2 50 kWh 8 Generators Each power meter can be a consumer or a generator If a meter is a generator the dial and legends are displayed differently 46 Wiser Home Controller 2 User s Manual Needle amp Dial The needle will show the following for each dial Gauge lee o In Gauge Number Inside each gauge there is an indicator displaying the current value and units This should be as follows Gauge _ Vaue legend Accumulated generation this day kWh kgCO Weekly Accumulated generation this week kWh kgCO Monthly Accumulated generation this month kWh kgCO Graphs Graphs are shown in the Stats area or can be seen by expanding the Power Meter Widget The figure below is indicative of Graph display in Flash In clients such as iOS Android Mobile and Android HDMI the display would be same in essence but with subtle differences 47 5 3 22 Wiser Home Controller 2 User s Manual Phase 3 THIS WEEK THIS MONTH Week Month Year 0 12 00 14 00 18 00 20 00 22 00 00 00 04 00 06 00 08 00 10 00 e The scale on the left side should match that of the gauge for the range displayed e In the event data is out of range the graph should flatten at the top but the mouse indication value should show the correct value e Mouse indicator values should show only hourly data not interpolated d
32. is will be as follows Current rate of generation consumption kW kgCO Accumulated generation consumption this day kWh kgCO Weekly Accumulated generation consumption this week kWh kgCO Monthly Accumulated generation consumption this month kWh kgCO The colour of the numeric value for each element including the under gauge elements should be green when generation is more than consumption and yellow when consumption is more than generation In the case that the value was negative in the previous hour i e that more power was generated than consumed then the text label should read Generated Last Hour In the event that more power was consumed than generated the label should read Consumed this Hour 49 Wiser Home Controller 2 User s Manual Pa A m a i b T e a t s kW gt Rate of Consumption Generation Estimated this hour kV Generated last hour kWh 6 FULLER je fe Rate of Consumpton Generaton Estimated this hour kWh Generated last hour kWh 8 Under Gauge Legend Under each gauge there is a legend The legend can have up to three lines of text below which will be 1 Gauge symbol with description of what dial is currently showing 2 Estimated generation consumption for this period 3 Generation consumption for previous period if available otherwise no legend will be displayed Graphs 50 5 4 5 4 1
33. nel as shown below EN To select change the Function Group click the Functions option to expand and then select one of the added Functions The selected Function Group will be shown highlighted in the left Panel with its corresponding widgets displayed in the right panel To select change the Location click the Locations option to expand and then select one of the added Locations The selected Location will be shown highlighted in the left Panel with its corresponding widgets displayed in the right panel Status Information Connection There will be various Connection related messages in case the Connection is not working In case everything is connected and working fine no error messages will be displayed Since a user can have both ZigBee and C Bus in their project the Error messages are represented 14 3 4 2 3 5 Wiser Home Controller 2 User s Manual such that user can still access the Ul and work with features functions which are accessible The only time the Ul will not be accessible is when connection to the Wiser 2 Home Controller would be lost i e either the controller is powered off or there is no Ethernet WiFi connection present Error Messages will be displayed when the following conditions occur General e No connection to the Wiser 2 Home Controller C Bus e No connection to C Bus ZigBee ZigBee interface not found ZigBee initialising Not connected to ZigBee network Connected to the wrong ZigBee n
34. nitialising e g during boot up ZigBee device discovery Green Good connection to ZigBee network updated every 10s Red ZigBee network not connected or error condition Off LEDs disabled or ZigBee not enabled 10 3 0 Wiser Home Controller 2 User s Manual 3 1 3 2 Using the User Interface Graphical User Interface The Wiser 2 Home Controller s GUI is an easy to use interface for accessing monitoring and controlling your residential or office envronment locally or remotely over the Internet You can access the GUI of the new Wiser 2 Home Controller Wiser 2 with a range of personal computing devices including hand held phones and tablets The Wiser 2 installation can include wireless devices in your home or business The control interface is set up by the installer integrator The user selects 1 a location such as a bedroom or lounge room 2 an application such as lighting heating or window shades and 3 a device or function such as a lamp or curtain relay When you change the state of a device the screen widget shows the change The installer sets up a profile for the user that allows access to certain functions and devices Concepts The Wiser 2 Home Controller web interface appearance depends on many factors including the selected Widgets A typical screen is shown below Scenes Admin f Home fe Cinema el Garden Sprinklers Functions Y Lighting HVAC Scenes Fans Security Powe
35. on for the tuner source Additional source controls Bass treble and balance Long list of transport buttons 38 Wiser Home Controller 2 User s Manual Tuner 1 Cinema D Treble Balance Nova 919 Volume 5 3 18 Homesafe Panel The Homesafe Panel widget is used for controlling and monitoring a Homesafe C Bus security panel Monitor There are several areas of the widget 39 Wiser Home Controller 2 User s Manual Panel status this shows whether the security panel is armed disarmed or has alarms Keypad this is used in the same was as a regular security panel keypad Alarm status this shows if any alarms have been raised and if yes which ones Zone status these show whether the zones are secure or not Alarms 0 Vitelalice Monitor Zone status 40 Wiser Home Controller 2 User s Manual 5 3 19 MinderPro Panel The MinderPro Panel widget is used for controlling and monitoring a MinderPro security panel Arm Ready Disarmed There are several areas of the widget Panel status this shows whether the security panel is armed disarmed or has alarms Keypad this is used in the same was as a regular security panel keypad Alarm status this shows if any alarms have been raised and if yes which ones Zone status at the right these show whether the zones are secure or not 41 Wiser Home Controller 2 User s Manual Arm Ready Alarms 0 Disarmed Awa
36. ontrolling some aspect of the C Bus system The details of the usage will depend on the project System IO widgets have a default icon All Ul clients will provide a method to enter the desired real value within the defined range and when the desired value is entered press Save to update User System IO String The User System IO String widget is used to display information of some aspect of the C Bus system The details of the usage will depend on the project System IO widgets have a default icon mooloba bolloba Pressing the Widget will have no effect as the string is not editable from within client applications User System IO Boolean The User System IO Boolean widget is used to select a boolean value ON or OFF for controlling some aspect of the C Bus system The details of the usage will depend on the project The appearance will be similar to a 2 State Lighting Relay widget The ON OFF states will be represented by buttons which will have ON OFF Label defined in the Project A button press will change the state from on to off or vice versa 52 5 4 5 5 4 6 9 9 5 5 1 Wiser Home Controller 2 User s Manual User System IO Date The User System IO Date widget is used to select a date for controlling some aspect of the C Bus system The details of the usage will depend on the project System IO widgets have a default icon 12 11 2013 All Ul clients will provide a method to enter the desired Dat
37. r s Locations Settings A Widget is a graphical component displayed on the Wiser 2 Home Controller User Interface and is used to control and or display the state of something Typical functions for widgets include e Controlling lighting e Controlling a home audio system 11 3 3 3 3 1 Wiser Home Controller 2 User s Manual e Controlling and monitoring a security system e Displaying a web camera TheWiser 2 Home Controller automatically arranges the widgets onto pages according to their Location and or Function Group If there are too many widgets to fit on a single page it is possible to scroll them left and right using the Scroll Pad Locations are used to arrange widgets according to their physical location in a site A project can have between 1 and 20 locations Typical Locations in a home might include Lounge Dining Bedrooms Outside Function Groups are used to arrange widgets according to their usage A project can have no Function Groups or up to 20 Typical Function Groups in a home might include e Lighting e Security e Climate Control e Media Audio Video At the bottom of the Locations list is the option for Settings which provides the ability to edit created Profiles Edit Scenes Edit Schedules Edit View the Network Settings and Edit Date Time The mentioned options are available in Flash and Android HDMI Client but in the Android and iOS Mobile Tablet application only a subset of th
38. s and shutters The general appearance of the widget is fixed The button labels and the name of the controlled device can be set 29 9 3 9 5 3 6 Wiser Home Controller 2 User s Manual There are three options e One button control a single button is used for up stop and down In this case with each button press the label will change based on the state of the curtain controller e Two button control one button is used for up stop and the other is used to down stop e Three button control one button is used for up one is used for down and the third is used for stop Two State Lighting Relay The Two State Lighting Relay widget is used for on off control of a load The appearance will depend on the label defined for the Off and On state A Short Press on the button will toggle the state between on and off Shutter Relay The Shutter Relay widget is used for opening and closing electric curtains blinds and shutters The general appearance of the widget is fixed The button labels and the name of the controlled device can be set 30 5 3 7 9 3 8 Wiser Home Controller 2 User s Manual Open Stop Close Close There are three options e One button control a single button is used for open stop and close e Two button control one button is used for open stop and the other is used for close stop e Ihree button control one button is used to open one is used to down and the third is to stop Lightin
39. schedule occurring on a regular basis for example every three days The interval is selected in Day of Month Last Week in Month this will result in the schedule occurring during the last week of the month The Schedule Days Months and Years can be combined in any way you wish The Schedule will only be executed on days where the Day ofthe Week Day ofthe Month Month and Year ALL match the selection 19 Wiser Home Controller 2 User s Manual Click on the Save button when you have finished making changes 20 4 2 4 3 4 4 4 5 Wiser Home Controller 2 User s Manual Using the Mobile Phone Application General The Wiser 2 Mobile Phone Application is an application which allows many devices in a home to be controlled from a mobile phone Android or iOS It requires a compatible mobile phone and a Wiser 2 Home Controller unit which is connected to a C Bus ZigBee system All phones are different so it is not possible to include instructions for details which vary between phones The user interface across all clients has been made as consistent as possible but there could still be some differences Mobile phone applications do not have all the options under Settings thus to access those options either a Flash or Android HDMI client would be required Requirements To run the Mobile Phone Application users will need and iOS 7 or Android 4 1 and above smart phone or tablet Getting the Application Using an iOS
40. setting screen fields require text number entries After making a change it will need to be saved and this will cause the Wiser 2 Home Controller to re boot Changes will not take effect if the Wiser 2 Home Controller is not re booted after the save Profiles This option displays all the Profiles part of the project Depending on the given rights the user can change the Username Password and Permissions for each profile For the default Admin profile the Username and Permission values may not be edited but the user may change the Password Note Any change made on this page requires a Save which will result in an automatic Wiser 2 Home Controller re boot after confirmation from the user Any changes made will not take effect until the Wiser 2 Home Controller is re booted Edit Scenes To edit the names of the scenes click on the Edit Scenes option under Settings Edit scenes Click on the Edit button next to the scene you wish to change series of sliders will appear one for each load in the scene Adjust the sliders until the levels are as required then click on Save Edit Schedules To edit the names of the schedules click on the Schedules option under Settings The appearance 18 Wiser Home Controller 2 User s Manual of the Edit Schedules page can vary under different Ul clients The picture below represents the Flash user interface Schedules Click on the Edit button next to the schedule you wish to ch
41. t of Schneider Electric Australia Pty Ltd Technical Support Hotline 1300 722 247 Australia Technical Support email cis_support clipsal com au Contact us clipsal com feedback Schneider Electric Australia Pty Ltd reserves i the right to change specifications modify National Customer Service Enquiries designs and discontinue items without incurring obligation and whilst every effort is made to Tel 1 300 202 525 ensure that descriptions specifications and Fax 1 300 202 556 other information in this document are correct no warranty is given in respect thereof and the company shall not be liable for any error therein Schneider Electric Australia Pty Ltd 2015 F2164 1 February 2015 30415751
42. that if you are connecting from the WAN side you will need to have enabled the Projector Control feature to enable external access to theWiser 2 Home Controller Enter the Username and Password based on the profile you want to connect with These will be stored in the unit and not requested in future unless you select to logout and clear it If you are connecting from the WAN side then SSL for Remote connection is advised to be turned ON so that the communication between the mobile client and Wiser 2 Home Controller is encrypted There is a Help button provided on the login page to give more details about the fields the user needs to enter on the login page as shown below This is what you need to set up this app with your Wiser WAN IP Address The static URL IP Address or Dynamic DNS URL you use to connect your Wiser from outside your home normally on port 80 in the form URL 80 Example www mywiser com 80 LAN IP The IP Address of your Wiser unit normally 192 168 2 1 Username and password The username and password you use to connect to the webpage of your Wiser Version 1 05 68 Android The following Welcome to Wiser 2 screen will be displayed in the Android application 23 Wiser Home Controller 2 User s Manual wiser HOME CONTROL Settings Pressing on the Settings button will display the following screen fp E E Wiser Settings Username Password LOCAL CONNECTION IP Address REMOTE
43. ure to disable Project Update after usage as leaving it open will allow anyone to modify your Wiser 2 Home Controller C Bus Date and Time The date and time is shown in the System Utilities page under Settings Save date and time DST Enabled The C Bus Date can be displayed in 4 different formats such as mm dd yy dd mm yy etc Similarly C Bus Time can be displayed in 12 hour and 24 hour format and these settings need to be done in the Misc tab of Project Details window in PICED The displayed time is the time on the Wiser 2 Home Controller unit and it is used for schedules and logic User also has the ability to enable disable daylight savings and this change does not require a Save as it is changed immediately on selecting the enable disable radio button Notes Make sure the C Bus network is connected when changing the time and date settings If the controller is set up to use Network Time Protocol NTP to get the time the UI will not allow the user to set the date and time Only the DST Enabled setting may be changed 17 3 9 3 3 5 4 3 5 5 3 5 6 Wiser Home Controller 2 User s Manual Setup This option allows the user to set up the following Language DHCP Server Settings Wireless Network Settings NTP SAMBA DDNS Manual Web Upgrade Changing settings on the Wiser 2 Home Controller can cause unexpected results Unless you are absolutely certain do not attempt to modify these settings Most of the
44. us network and to poll the states of the C Bus devices through the C Bus Network Interface CNI This is important to give a true picture of the status of the equipment In case ZigBee network is connected or Ripple is enabled please allow time for the connection to fully establish which will be indicated by the Green LED on Wiser 2 Home Controller Try to avoid disconnecting power from the Wiser 2 Home Controller equipment It is better to let it remained powered on than to remove power on a random basis You can get a good indication of the status of the system from the indicator LEDs on the Wiser 2 Home Controller depending on what is connected to the controller Some activity between the controller and C Bus network is normal at any time even when not being controlled or monitored by 13 3 3 3 3 4 3 4 1 Wiser Home Controller 2 User s Manual you using the Wiser 2 UI During maintenance events such as using C Bus ToolKit via a remote CNI transferring a project to the Wiser 2 unit using PICED or when the controller is rebooting or performing power on self tests the Wiser 2 User Interface will not respond to input or display changes Navigation On connecting to any client the user will always be taken to the Home Page displaying the Favourites if any User will also see a left Panel in Green which shows Home Functions Locations and Settings and right panel in black which shows widget data based on the selection in the Left Pa
45. widgets will look for tuner external input and Ripple External Input Streaming MP3 input Ripple and USB Cinema Ls Lhe Antonio Ban Evita Motion Picture Music Soundtrack Press the artwork to expand to the Ripple user interface which allows you to select songs based on artist genre albums and so forth This view also allows you to create a playlist 36 Wiser Home Controller 2 User s Manual ul Telstra Close Queue Song title gt And The Money Kept Rolling Artist Antonio Banderas And The Money by Antonio Ban ul Telstra Close Tuner input 3 Album Evita Motion Picture Music Artists A 360 Artists A Trak amp Dillon Francis AC DC AWOLNATION Aerosmith Andrea Corr Jonathan Pryce Mad Antonio Banderas Antonio Banderas Gary Brooker Antonio Banderas Jimmy Nail Jo Antonio Banderas Jimmy Nail Juli Antonio Banderas Jonathan Pryc Antonio Banderas Madonna Asaf Avidan amp The Mojos Avicii B B King U2 Bingo Players Wiser Home Controller 2 User s Manual Using the controls on the Widget the user is able to e Change source using the gt button e Control volume including a mute button e Short list of transport buttons Clicking on the button with the source name will open an expanded view which provides additional control Selection of play lists for the streaming source Selection of radio stati
46. will be set at the end of the period using the ramp rate if defined Enable Preset The Enable Preset widget is generally used for enabling a function ofthe C Bus system such as a scheduled event The appearance will depend on the icon selected The icon widget label and preset level will show whether the load is at the preset level indicated by the colour green A Short Press on the Preset Level panel will set the item to the Preset level 32 5 3 11 5 3 12 5 3 13 5 3 14 Wiser Home Controller 2 User s Manual Two State Enable The Enable Preset widget is generally used for enabling a function ofthe C Bus system such as a scheduled event The appearance will depend on the label defined for the Off and On state CQ 2 State Enable Sample Disabled The button press will toggle the state between on and off Fan Controller The Fan Controller widget is used for controlling the speed of a ceiling fan The current speed of the fan is shown on the second panel 4 Fan Controller a Medium A Short Press on the and buttons will change the fan speed If the fan is on a short press on the fan will switch it off User can cycle through the speeds using any button Scene Trigger The Scene Trigger widget is used for setting a scene This allows many lights to be set to pre determined levels all at once The appearance will depend on the Icon selected The icon widget Label and ON will show wh
47. y Night Zone status m 5 3 20 Climate Control The Climate Control widget allows the user to control and monitor the following aspects of an air conditioning system 1 Switch the air conditioner on and off 2 Monitor room temperature 3 Set the operating type e Heat e Cool e Heat Cool 42 Wiser Home Controller 2 User s Manual e Fan vent 4 Set the temperature set point 5 Set the fan speed 6 Switch the zone air flow damper on and off Zone Status HVAC Modes A U to Fan Speed Current Temper ture O v 2 i C T Set point Power off plant HVAC Plant ON OFF 5 3 21 Power Meter Power Meter Widgets are used for monitoring the power usage They can display the power level from a measurement or pulse power meter The Widgets look and operate the same regardless of the type of power meter being used The following units would be displayed in a power meter power meter totals e kW Kilowatts to two decimal places e kgCO per kW Kilograms of carbon dioxide per kilowatt Each Power Meter widget will consist of a gauge with a dial displayed 43 Wiser Home Controller 2 User s Manual TELLLLITETY au WF i TI amt fs se J Rate of Consumption Estimated this hour 3 00kWh There are four dials for each widget e Now e Daily e Weekly e Monthly Gauges are selected by swiping in iOS and Android or by clicking on the widget panel in the Flash and TV client Needle amp