Home
Sliding Gate Operator User's Manual
Contents
1. I R ail Signal GND e 24VDC Infrared COM Terminal X2 24VDC Control board Infrared with DC input ENVIRO 6 SLIDING GATE OPERATOR Fig 9 infrared Schematic diagram Three button switch single button switch keypad The ENVIRO 6 is equipped with interfaces for three button switch and single button switch keypad To install the keypad attach one lead of your keypad to CLS of terminal X4 and the other to the COM The keypad will function in single channel mode the DIP switch 1 should be turn to OFF For three button switch installation use the terminals for multi channel mode Connect open wire of external button switch to OPN of terminal X4 connect close wire of switch to CLS connect stop wire of switch to STP connect common wire of switch to COM terminal X4 terminal X4 OPN Open OPN CLS Close CLS Keypad STP Stop STP eo COM Common COM 2 Control board f Control board Single button switch terminal block MS terminal block Fig 10 Motor and capacitor Terminal X2 X3 V com U Positive direction W Opposite direction E grounding C capacitor V U W Capacitor Motor C c E V U W Control board Terminal X3 Terminal X2 Fig 11 7 Tuning and operation Remote control The remote co
2. Se PHOENIX DOORS Sliding Gate Operator User s Manual ENVIRO 6 http www phoenixgaragedoors com au ENVIRO 6 SLIDING GATE OPERATOR OUTLINE 1 Products introduction sees ee ensen ene senen sen nen venen 2 2 Important safety precautions serrrrsssrereeeeee eee vee Ee EE ee 2 3 Main technical parameters sesse ee ee EER EE see eee ee 2 4 Mechanical Installation sesse eneen ens se nennen ven vennen 2 5 Adjustment ernreernenvenseenanvernenene vernam See Ee ee nennen 5 6 Wire Connecting sterre EER EER EE vernam eer vennen eeen ereen 6 7 Turning and operation sees ver se ee EE Ee EE Ee Ee es see see B 8 Programming Process sesse ses see ses ee Es vee nen vee EE ee eg 10 OM ETC ER ER ee er re 11 10 Trouble RE ven ven ven NE 11 Packing list verververvenvenvenvenvenvenvenvenvenvenvenvenveneen 11 12 Warranty Registration MR TE er Meee swe serene 12 ENVIRO 6 SLIDING GATE OPERATOR 1 Products introduction please read the instructions carefully before proceeding MCU is supplied to control the gate operator Keypad single button interface Photo beam safety beam interface User can select Auto close function Manual key release design for emergency purposes 2 Important safety information Carefully read and follow all safety precautions and warning before attempting to install and use this automatic gate operator Make sure the Power supply AC220V of the gate operator is suitable for the p
3. OPEN button If the gate stops at closed position when the limit switch is reached the gate will not move if you press CLOSE button The device is installed with a thermal protector the thermal protector will switch off the motor automatically in case of the temperature is higher than 120 C and switch on the motor automatically when the temperature is lower than 85 C 5 C 9 Maintenance Check the door once a month The door should be carefully checked for balance The door must be in good working order We suggest for safety reasons photocells be used on all gates Disconnect from mains supply before replacing bulb Be sure to read the entire manual before attempting to perform any installation or service to the door operator Our company reserves the right to change the design and specification without prior notification 10 Troubleshooting Trouble Possible causes Solutions The door fails to open P 1 Power is OFF 1 Make sure that power is ON and close LED display 2 Fuse burn 2 Replace fuse does not light 1 Infrared beam is obstructed 1 Remove obstructions The door can open fails 2 Infrared photocell function is 2 Make sure the infrared to close enable but the photocell has not Photocell function is disable been installed Remote transmitter does 1 Battery level may be low transmitter not work 2 Transmitter code is lost 2 Re program the trans
4. the same remote control button the gate stops running And the LED2 is turns off Then press CLOSE button or the same remote control button again the gate will close the motor rotates anticlockwise and the LED2 is turns on The output voltage between D1 and D2 terminal X3 is AC220V the voltage between V and W is AC220V Press the STOP button or the same remote control button the gate stops running And the LED2 is turns off Verify open direction If the gate does not move in the desired direction then you will need to reverse the motor operating direction open the black plastic cover you can do this by exchanging wires U and W OPLT and CLLT ENVIRO 6 SLIDING GATE OPERATOR 8 Porgramming Process Table of the DIP switch Position DIP switch Function SET ON Three button switch 1 Single button switch the CLS and COM OPN and COM is open OFF door function also 5 ON When the 2 and 3 all ON the Controller haven t Auto close OFF function When the 2 ON and the 3 is OFF auto close time is near 20 Sec when the 2 OFF and the a is ON auto close time is near 3 oN 40 sec when the 2 and the 3 is all in position the auto close time OFF is near 60 sec Note 1 You must follow the operating instruction as above any wrong operation is not allowed during setting If your device responds to your requested function correctly you have set the function successfully otherwise repeat the abo
5. anually use the release key as follow Fit the supplied key in the lock Turn the key and pull down the release bar about 90 to release the gear Note Do not exceed 90 be careful not to use too much force otherwise the release bar will be damaged Open and close the gate manually Note If the gate bumps the mounting post and cannot be electric opened move the gate a few inches by hand thus you can release the gate with the key open and close the gate manually Fig 7 6 Wire Connecting Make sure that the power is OFF before making any electrical connections Remove the cover perform the wiring See Fig 8 and wiring notes for control board and replace the cover again ENVIRO 6 SLIDING GATE OPERATOR ANT Ant Gnd Gnda Data SV oo Te REV 00 0 e e ee 9 Pp o CES 1 Er e STP o CO e 30 PLM COM Ki CLLM R GND 24V Dd Wiring notes of control board a Power Input X1 E Earth L Live N Neutral ENVIRO 6 AC220V b Caution light connect caution light wire toD1 and D2 terminal X3 ENVIRO 6 AC220V c Output power supply 24VDC COM COM I R N C Infrared If the infrared beam is interrupted during closing the gate will reverse and open immediately The product is not factory equipped with an infrared device the infrared output signal must be N C
6. ear to the previous one Move the gate manually and affix the three nuts as the first rack thus proceeding until the gate is fully covered ENVIRO 6 SLIDING GATE OPERATOR When the rack has been installed to ensure it meshes correctly with the gear The space between rack and gear is about 0 5mm 5 Adjustment Spring limit switch To ensure safety it is recommended to install limit switches at both ends of the gate to prevent the gate from sliding out of the rails The rails must be installed horizontally Install the limit block as shown in Fig 4 and Fig 5 The spring limit switch and blocks are used to control the position of the gate Release the gear with the key and push the sliding gate manually to pre determine the position fix the block to the rack and lock the gear by push up the release bar Moving the gate electrically adjust the block to the proper position until the position of the opening and closing meet the requirement Sliding gate Spring of limit switch 7 Limit block Rack Gear o le oO co H i 197 i Fig 5 ENVIRO 6 SLIDING GATE OPERATOR N M6X10 Fig 6 Manual operation In case of power failure use key unlock the lock and pull down the release bar about 90 degree to open or close gate m
7. hat no damage can result from contact with any rough or sharp part Concrete pad The base unit of the gate operator requires a concrete pad in order to maintain proper stability The concrete pad should be approximately 400mm x 250mm x 200mm deep in order to provide for adequate weight and structure to insure proper stable installation Anchors see Fig 2 You can use anchor bolts anchors washers and nuts These anchors must be set into the concrete when it is poured or you can use wedge anchors to fasten the operator ENVIRO 6 SLIDING GATE OPERATOR Gate operator Gear A Nut Spring washer Plain washer Nut Groundsill Input power Fig 2 Operator base see Fig 3 After the concrete has hardened mount the gate operator base to the concrete pad Verify that the base is properly leveled Using bolts and washers mount the gate operator to the base and insert the cover Check the operator and make sure it is lined up with the gate 100 253 Fig 3 Installation of Rack Fix the three nuts in the same package with rack on the rack element Lay the first piece of rack on the gear and affix the first nut on the gate Move the gate manually checking if the rack is resting on the gear and affix the second and third nut Bring another rack element n
8. mitter 1 Replace the battery inside the The transmitter operating i i Battery level may be low Replace battery distance is too short 11 Packing list After receiving the gate operator you should make an unpack inspection in which you should check whether the product was damaged If you have any problem please contact our dealer You should find the following items in our standard packing ENVIRO 6 SLIDING GATE OPERATOR No Item Quantity 1 ENVIRO 6 sliding gate operator 1 2 Transmitter 2 3 Release key 2 4 User s manual 1 12 Warranty Registration For your operator warranty registration please visit our website www phoenixgaragedoors com au warranty registration
9. ntrol works in a single channel mode It has four buttons See Fig 12 Remote transmitter The function of button 1 button 2 button3 and button 4 are the same With each press of the remote control button which has been programmed the gate will close stop open or stop cycle You can program learn button 1 button 2 button 3 individually You also can program learn two 8 ENVIRO 6 SLIDING GATE OPERATOR buttons or three buttons together but you need repeat the program learn process if you want to use more than one button Button 1 Button 2 Button 3 _Button 4 Fig 12 Remote transmitter Adding extra remote controls Learn Remove the cover press the learn button AN1 Fig 8 then the LED2 Fig 8 will be on and turn off then press the remote control button which you want to use the LED2 will turn on about 2 seconds and then turn off again The learning process is finished Up to 25 remote controls may be used Erase remote controls To erase all existing remote controls press and hold learn button AN1 the LED2 turns on release the button once LED2 turns off This indicates that all the remote controls have been erased completely Note Press the OPEN button of external button switch or remote control button which has been learned the gate will open the motor rotates clockwise and the LED2 is turns on The output voltage between D1 and D2 terminal X3 is AC220V the voltage between V and U is AC220V Press STOP button or
10. ower supply in your area 3 Main technical parameters Type ENVIRO 6 Power supply 220V 50Hz Motor speed 42rpm Rated output power of motor 150W Remote control operating distance 30m Frequency 433 92mHz Remote control mode Single button Output shaft height 58 5mm Max gate weight 500Kg Output torque 14N m Limit switch Spring limit switch Noise lt 60dB Duty cycle S2 15 minutes extra remote control 20 Environmental temperature 20 C 50 C Gate Move speed 12m min 4 Mechanical Installation The ENVIRO 6 will handle gate weighting up to 500kg and up to 12m if the proper installation procedures have been followed The ENVIRO 6 gate operator operates by forcing a drive rack by a drive gear is shown in the diagram below The gate operator must be installed on the inside of the gate The entire configuration ENVIRO 6 SLIDING GATE OPERATOR Switch Sliding gat Input power Fig 1 Gate preparation Be sure the gate is properly installed and slides smoothly before installing the ENVIRO 6 sliding gate operator The gate must be plumb level and move freely Conduit In order to protect the cable use PVC conduit for low voltage power cable and control wires Conduit must be preset into the concrete when it is poured Wires within the conduit shall be located or protected so t
11. ve setup instruction until your device responds to your expected function 2 If the gate can not be moved please check whether the gate is obstructed or the gate is too weight Activities Covered in this section Remote transmitter With each press of the button the gate will close stop open or stop cycle Single button mode Three button mode external button switch not supply press OPEN button the gate opens Press STOP button the gate stops Press CLOSE button the gate closes Single button mode external button switch keypad not supply With each press of the button the gate will close stop open or stop cycle Auto close function This feature can be selected to make the gate stay open for some seconds before it automatically closes The auto close time can be adjusted to between 15 30 and 45 seconds Safe guard Infrared photocell If infrared beam is interrupted during closing the gate will reverse and go open immediately This feature will not function if the gate is in fully opened and closed 10 ENVIRO 6 SLIDING GATE OPERATOR positions or during opening Open priority The gate will return to open if press OPEN button of external button switch during closing Limit switch The switch is used to accurately stop the gate in the opened and closed positions If the gate stops at opened position when the limit switch is reached the gate will not move if you press