Home
        user manual 2012 - Auskay International
         Contents
1.       Excel Power Vac    CENTRAL VACUUM SYSTEMS    Proudly Manufactured By Auskay International       User  amp  Maintenance  Guide       HOME OWNERS OPERATING  amp  MAINTENANCE INSTRUCTIONS  PLEASE READ AND SAVE THESE INSTRUCTIONS       fh   fi    ANET  ALZ  anur    N 24 Micro Circuit Dandenong South Vic 3175  A     S KA   Tel  03 9799 3055   Fax  03 9798 0386  INTERNATIONAL www duskay com au sales auskay com adau    Manufacturing   Installations   Services Te Pa  gor thase uho value only the best     DUCTED VACUUM SYSTEMS   VIDEO DOOR PHONES   SECURITY ALARM SYSTEMS   CCTV SYSTEMS          Excel Power Vac User and Maintenance Guide    Congratulations on choosing EXCEL Power Vac Series II Central Vacuum System    Your vacuuming will be quieter  easier and healthier with all the dust and dirt being removed from the house to the main unit  located in the cellar  garage or outside  this is a great benefit to people who suffer with allergies  hay fever  asthma or respiratory  problems  Your new EXCEL Power Vac System is designed and manufactured in Australia by Auskay International Pty  Limited     OPERATING  amp  CARE OF YOUR VACUUM    Make sure the power unit is turned on at the power point  and that the on   off switch on the front of the unit is turned off   Simply plug in the cuff end of the hose in the inlet valve located inside the house and the vacuum unit will switch on  automatically   Except where it is a Switchable Hose     After vacuuming you should let the vacuum u
2.    Damage resulting from the use of the vacuum unit without the filter or bag installed      Damage to the other parts of the system such as pipes  tools  inlet valves  wands  hoses      Motor damage due to incorrect maintenance  obstructed ventilation holes  over voltage  lightning strikes  ingress of water or other  liquids      Removal and re installation costs  except as per clause 2 above      Freight of parts to and from Auskay dealer or agent  except as per clause 2 above     
3.  EXCEL 4000 EXCEL 5000   Filtration Bagless  amp  bag  2 in1   Bagless  amp  bag  2 in 1   Bagless  amp  bag  2 in 1   Power consumption  watts   am   T aeai    WARRANTY    Sealed vac mm H2O  max  3162       Auskay International Manufacturing  amp  Trade Pty  Ltd  hereby warrants its EXCEL POWER VAC for 2  3  4 or 6 years subject to the  conditions specified herein    1  Warranty applies if the unit is proven to be defective due to faulty workmanship or materials during the warranty period  provided  that the system has not been modified  tampered with or repaired by any person other than an authorised employee or dealer of  Auskay    2  Where an authorised Auskay dealer or agent has installed the system  this Auskay dealer or agent shall remove  repair or replace  and refit the defective part free of charge for the first ninety  90  from date of purchase  Any cost associated with traveling outside  the metropolitan area is not covered and shall be paid by the purchaser  For the remainder of the warranty period  any defective  parts will be repaired or replaced if delivered to Auskay or its dealer or agent    3  Where an authorised Auskay dealer or agent has not installed the product  the defective part will be repaired or replaced free of  charge during the warranty period when delivered to place of purchase or the dealer or agent of Auskay     This warranty does not cover the following      Fair wear and tear and consumables such as motor brushes  bearing filter  bag etc   
4.  kind of residential building  house  office  hotels  service building  consists of a network  of PVC pipes throughout the house  strategically positioned for maximum coverage  The pipe network is equipped with suction inlets   The Excel Power Vac unit must be installed in a separated room  for example in a storage room  in a garage or in another service  room  and is connected to the pipe network   The user starts the Excel Power Vac unit by simply inserting the fitting of the hose into the pipe inlet  If the hose is equipped with an on off switch the user can control the Excel Power Vac unit by using this switch     Excel Power Vac User and Maintenance Guide    MAINTENANCE     ATTENTION   ALWAYS UNPLUG THE POWER CABLE FROM THE POWER SOCKET AND ALWAYS WEAR  PROTECTIVE GLOVES AND GOGGLES BEFORE CARRYING OUT ANY MAINTENANCE    Programmed maintenance   In order to keep the system perfectly operating and to avoid any possible mechanic trouble  the user must overhaul the whole  system at precise time intervals  according to the accumulated operating time of the VAC unit    For the Excel Power Vac systems maintenance  keep to the instruction detailed in the table below        User       Replace the dust bag    32 Clean the dust bin User    54 Control the obstruction level of the air exhaust Technical service    The casing of the suction unit needs periodically cleaning  Use a smooth and damp cloth with some neutral soap   Attention  Be sure to use only water or water with neutral 
5. ON    The User Guide   The user guide is a fundamental document written by the manufacturer  to be considered an integral part of the central suction unit  In  case of resale   offering or lease to third parties  the user guide must be handed over to the new user or to the new owner  The  manufacturer must be informed about any ownership change   We recommend storing and keeping the user guide throughout the  whole operating life of the suction unit    The main purpose of the user guide is to provide a correct knowledge of the user mode in order to exploit the best working and security  conditions  It is absolutely forbidden to duplicate  copy or release totally or part of this user guide without previous written authorization  by AUSKAY INTERNATIONAL  owner of the trademark EXCEL POWER VAC     Safety and Security Precautions   Read carefully any information written in this central vac user guide regarding installation  use and maintenance of the central vac unit   Call the Auskay Factory or Authorised Dealer for any information you may need  Make sure the central vac has been correctly fitted   NEVER operate this machine near open containers of flammable solvents  dry chemicals  cleaners or varnishes  fumes from such  substances and air form a mixture that can ignite from a motor spark    Where this vacuum unit is installed below combustible floor or ceiling materials and the distance between the top of the machine and  the ceiling or floor is less than 900mm  fit a 600x600 
6. able heavy duty motors are sourced from Europe  A proprietary printed circuit board controls all the functions of the  power unit  Internal sound insulators significantly reduce the level of noise emitted by the unit    The main body of the power unit is made of a heavy duty ABS polymer material  which means that you will never have to worry  about dents or corrosion  Automotive standard UV stable paint finish is applied to all exterior surfaces to create modern and stylish  appearance        a N    Exhaust    ABS polymer top COV OY rssssss        Electric suction motor    Low voltage connectors stipes AAA s    Manual override switch     ABS polymer Dody tment    Power Co rd IEE E A E E E A A T    Latch lock d ust bin nnn    Metal mounting bracket                    x  of    Identification plate                   Power Rating Voltage Rating Serial Number                                   N3651       4   ____        Model Number AS Number                               Excel Power Vac User and Maintenance Guide    Technical features   Unique design allows the same power unit to function with a disposable bag or without   the choice is up to the user  Dual inlets  and a special bracket design make installation flexible and simple  Twist lock dust bin attachment makes emptying a breeze   Balanced motor air intake and exhaust removes excess heat out of the motor  Shower proof design is suitable for internal or  external mounting without a rain canopy  additional parts required    
7. cement sheet above machine    DO NOT let the children get near the central vac unit when it is working and never let children play with suction inlets or with vac unit   DO NOT install unit in a confined area or without adequate ventilation    DO NOT operate machine without a filter or bag    DO NOT vacuum any of the following    Flammable liquids  inflammable chemicals  powdered coal  cement  lime and plaster of paris powders  including talcum powder   flour   starch or grain dust  glass fragments  textile materials  aluminum  magnesium or other metal dust     Unplug the central vac unit when      The power supply cable is worn out or damaged      The central vac unit has been exposed to the inclemency of the weather or excessive moisture      The central vac unit has been damaged by an impact or external container has been damaged      The central vac unit requires any repairing or overhauling    Always wear protective gloves and mask when carrying out any maintenance operation  and when unloading the dust container or  replacing cleaning the filter    Use only AUSKAY original spare parts    Never block the air exhaust pipes and the cooling inlets of the motor    Use only one inlet at a time    If you are not going to use the central vac unit for a long time  it is advisable to turn the power off from the wall switch and unplug the  power cord from the power point     DESCRIPTION OF THE EXCEL POWER VAC UNIT  Operating principles  The Excel Power Vac system  suitable for any
8. ly and  than mixed up in the dust container  It is strictly forbidden to use the Excel Power Vac unit in explosion hazard places or in places  where temperature  pressure and moisture are out of range     Any different use is strictly forbidden    The manufacturer  by means of written authorization  must approve any alteration or modification of the suction unit to remove a  specific material  Any use different from the original is to be considered improper and health risk for the user and damage to the  vac unit cannot be excluded     Compliance with the requirements and the relevant provisions of the AS directives in force  The Excel Power Vac units  which are  the object of this user guide  fully comply with the requirements and the relevant provisions of the Australian Standards directives     Excel Power Vac User and Maintenance Guide    HOW TO USE THE EXCEL POWER VAC UNIT               1   Starting of the Excel Power Vac unit    Plug the power cord to the power point and  turn the power switch on  Make sure the    switch on the Power Unit is in OFF position   this switch is to start the unit manually        2   Use of the Excel Power Vac unit       Fit the suitable floor tool or accessory for  the cleaning job you want to carry out    ar   Ga    Fit the opposite end of the hose in to the  suction inlet and the Power Unit will start  automatically  If you are using the switch  hose  turn on the switch located on the  handle to start the Power Unit        After finishing 
9. nit run for several seconds before removing the hose from the inlet valve to  ensure that all the dirt and dust has reached the main unit  this will reduce the chance of build up of dirt in the pipes    When vacuuming curtains and delicate objects you can use the pressure release valve located on the curved wand to reduce  the suction    When you use the valve on the main unit you need to switch on the unit manually by the on   off switch located on the front  of the unit    It is not recommended to use more than one inlet valve at the same time  as this will reduce the suction and could cause  blockage    You should not at any time vacuum plaster powder  heavy objects or liquids    The bag or filter must be in place before the unit is turned on    failure to do so will cause motor failure and void warranty      If poor suctions occurs you should replace the bag or clean the filter  where applicable   it is recommended to do this once a  month  more frequently for new home until carpet settles down to have problem free operation     Contents Optional Extras  1   Power Unit  Spare Filter   2   Telescopic wand  Muffler   3   Upholstery tool Turbo Brush   4   Hanging bracket  Canopy   5   9m flexible hose  Hose Sock   6   Dual floor tool  Hose Hanger   7   Crevice tool  Vacpan   8   Dusting brush  12m Hose Kit   9   Rod Holder Spare Dust Bags    10   Dust Bag          Ci J  M rm 9   N g    tom    S  CDD              Excel Power Vac User and Maintenance Guide    GENERAL INFORMATI
10. soap  Alcohol or other solvents may damage the unit  Wait until the unit  is perfectly dry prior to start it     SERVICING  Servicing criteria  It is strictly forbidden to operate on the Excel Power Vac to carry out any maintenance or servicing not mentioned  and therefore  not allowed  in the user manual  Only qualified technicians can carry out any maintenance or repair operations  The guarantee  will not apply in case of interventions carried out by non authorised staff and the manufacturer cannot be considered responsible  for possible injuries to persons or damage resulting from this kind of intervention     DISMANTLING  General Instructions  When dismantling the central suction system  dispose appropriately of used parts or material  which could endanger human health  or well being as well as the environment if handled improperly  You must be acquainted with sites companies authorized to collect  and dispose of used parts and materials  The disposal and or recycling of any part of the suction system must be carried out in  compliance with the legal regulations in force     USAGE  Correct usage  The Excel Power Vac systems have been designed to remove the dust  small particles and and dry materials  It is forbidden to use  the vac system to remove textile materials  plaster dust etc   burning and hot materials  It is strictly forbidden to remove highly  explosive materials  gun powder  or inert materials  which can trigger dangerous chemical reactions if removed separate
11. the cleaning job  remove the hose from the suction inlet and the Power Unit will stop automatically             Excel Power Vac User and Maintenance Guide    Maintenance of Self Cleaning Filter    Excel Power Vac Units come with self cleaning filter fitted  Self cleaning filters  may get clogged over the time and needs to be removed and cleaned        ATTENTION   ALWAYS UNPLUG THE POWER CABLE FROM THE POWER SOCKET AND ALWAYS WEAR  PROTECTIVE GLOVES AND GOGGLES BEFORE CARRYING OUT ANY MAINTENANCE                A        lt 4 hold the loop with your finger       g pull the loop towards centre     lt  squeeze filter and pull down the loop        lt q pull and remove the filter                Excel Power Vac User and Maintenance Guide    Replacing the dust bag    Excel Power Vac Units can be used with dust bags  recommended    Dust bags should be checked and replaced when full           li    ATTENTION   ALWAYS UNPLUG THE POWER CABLE FROM THE POWER SOCKET AND ALWAYS WEAR  PROTECTIVE GLOVES AND GOGGLES BEFORE CARRYING OUT ANY MAINTENANCE       e          m           lt j unlock the latches  amp  remove the dust bin           pull down and remove the old dust bag        lt     insert new dust bag on to bag adaptor     lt     replace the dust bin  amp  lock the latches       a          Excel Power Vac User and Maintenance Guide    Construction features  see picture    Only top quality components are used in the construction of the Excel Power Vac without compromise    The best avail
    