User Manual - CPAP Sales
Contents
1. NOT automatically start Adjusting the Circuit 2 Adjust the circuit Lie down on your bed and adjust the flexible tubing so it is free to move if you turn in your sleep Adjust the mask and headgear until you have a comfortable fit and there are no airflow leaks into your eyes Using the Ramp Button Pressing the ramp button will reduce the air pressure when you are trying to fall asleep The air pressure will gradually increase until your prescription pressure is reached If your physician prescribed ramp for you pressing the button will reduce the pressure and then gradually increase ramp the pressure to the therapeutic pressure setting so that you can fall asleep more comfortably Vote The ramp feature is not prescribed for all users 3 Press the Ramp button on the top of the RESmart Auto You can use the Ramp button as often as you wish during the night Turning the System OFF 4 Remove the mask and headgear Press the pressure start stop button on the top of the RESmart Auto to stop the airflow Or if the Auto Off setting has been enable the airflow will automatically turn 16 26 English RESmart Auto User Manual V2 5 off IMPORTANT The humidifier button is active only when an InH2 Heated Humidifier is connected or when the RESmart Auto is in the Setup Menu Refer to the InH2 Heated Humidifier s instructions for additional information Helpful Hints e If the alert tone sounds press any button o
2. b Insert the filter into the filter area on the back of the RESmart Auto 17 26 English RESmart Auto User Manual V2 5 Replace the filter cap CAUTI ON Never install a wet filter into the RESmart Auto We recommend that you clean the filter in the morning and alternate using the filter provided with the system to ensure enough drying time for the cleaned filter Cleaning the System Clean the mask and tubing daily WARNI NG To avoid electrical shock unplug the RESmart Auto before cleaning Do not immerse the RESmart Auto in any fluids 1 Disconnect the flexible tubing from the RESmart Auto Gently wash the flexible tubing in a solution of warm water and a mild detergent Rinse the tubing thoroughly and air dry 2 Wipe the outside of the RESmart Auto with a cloth slightly dampened with water and a mild detergent Let the RESmart Auto dry before plugging in the power cord 3 Inspect the RESmart Auto and all circuit parts for any damage after cleaning Replace any damaged parts 4 For details on cleaning your mask and accessories refer to the cleaning instructions packaged with the accessories Reordering Contact your home care provider to order accessories or Replacement filters Service The RESmart Auto system does not require routine servicing The RESmart unit contains electrical and or electronic equipment When necessary dispose of the RESmart and accessories in accordance with local
3. errr rrr rrr rrr rrr rrr rr rrr errr 15 Adding Oxygen eee PCCP CeCe CCPC eee eee Pee ee ee eee eee eee eee eee eee eee ee 15 Routine Use eee eee Pee ee eee eee eee eee eee eee ee eee eee eee ee eee eee eee eee eee eee eee 16 Connecting the Circuit eee eee eee eee CeCe eee eee CeCe eee eee eee eee eee eee ree 16 Adjusting the Circuit ete CeCe eee eee eee eee eee eee CeCe Cee eee eee eee eee eee er 16 Using the Ramp Button nnn nn an nn CeCe eee eee eee eee eee ee ee eee eee 16 Turning the System OFF eee Pee Pee CeCe PCC eee CeCe CeCe eee eee ee eee eee eee ey 16 Helpful Hints OPP Pee CCCP CPPCC eee eee Cee eee eee eee eee eee eee eee eee ee eee 17 Routine Maintenance a nn nnn nnn n a nn CeCe eee eee eee ee ee eee eee ee ee eee ee eee eee ee 17 Cleaning the Filter NN r errr rere r rrr rrr rrr rrr rrr nm mm 17 Cleaning the System eee eee CeCe eee CeCe eee CeCe eee CeCe CeCe eee rere ee eee 18 Reordering Dzggg2x2x x xmDgzggg ggmgngngggummsgm 18 Service Dg gt gt 222x2x2x2xrp ggggggggggggggggggngggggg g_uuz_ uuuu_ _ z 18 Traveling with RESmart EA A a ar 19 Troubleshooting nannnnnnnnnnnnannnnnnnnnnnnnnnnnannnnnnnnnnannennnnnnnnnnnnnnnnannnnnnannn 20 EMC Requirements NN RN eee ee eee eee eee eee ee eee eee 21 Limited Warranty n n kana aka aa ra aa aa aa aa raa aa aa aa aa aa a aa a a aa a aa a a a a a a a a aa a 26 English RESmart Auto User Manual V2 5 Symbols Control Buttons Pressure Start Stop Ramp Start
4. of positive airway pressure therapy for some patients e Bullous Lung Disease Bypassed Upper Airway Pneumothorax Pathologically Low Blood Pressure Pneumocephalus has been reported in a patient using nasal Continuous Positive Airway Pressure Caution should be used when prescribing CPAP for susceptible patients such as those with cerebral spinal fluid leaks abnormalities of the cribriform plate prior history of head trauma and or pneumocephalus Chest 1989 96 1425 1426 The use of positive airway pressure therapy may be temporarily contraindicated if you exhibit signs of a sinus or middle ear infection Contact your health care professional if you have any questions concerning your therapy 2 26 English RESmart Auto User Manual V2 5 Specifications Device Size Dimensions 220 x 194 x 112 mm 313 x 194 x 112 mm with InH2 heated humidifier Weight 1 6kg 2 4 kg with InH2 heated humidifier Product Use Transport and Storage Operation Transport and Storage Temperature 5 to 30 C 20 to 55 C Humidity lt 80 Non condensing lt 93 Non condensing Atmospheric Pressure 860 to 1060 hPa 500 to 1060 hPa Mode of Operation Continuous Work Mode CPAP Auto Titrate AC Power Consumption 100 240V AC 50 60Hz 1 0A max Type of Protection Against Electric Shock Class II Equipment Degree of Protection Against Electric Shock Type BF Applied Part Degree of Protection Against Ingress of Water IP
5. on monitoring of apnea and snoring events Auto Off When this feature is enabled the device automatically discontinues therapy whenever the mask is removed Auto On With this feature the device automatically initiates therapy when you begin breathing on the device This feature is always enabled CPAP Continuous Positive Airway Pressure iCode A feature that is intended to give access to compliance and therapy management information using encrypted codes The iCode consists of six separate codes displayed in the patient menu LPM Liters Per Minute OSA Obstructive Sleep Apnea Patient Setup Menu The display mode in which you can change patient adjustable device settings such as the ramp starting pressure 7 26 English RESmart Auto User Manual V2 5 Ramp A feature that may increase patient comfort when therapy is started The ramp feature reduces pressure and then gradually increases the pressure to the prescription setting so you can fall asleep more comfortably Reslex A therapy feature that provides pressure relief during exhalation if enabled by your home care provider Standby State The state of the device when power is applied but the airflow is turned off Titrate A therapy that delivers CPAP therapy while automatically adjusting the pressure level to meet the patient s needs First Time Setup WARNI NG Do not use the RESmart Auto system until an appropriate professional adjusts the sett
6. pees Humidifier On Off F User Button User Button Device A Attention Consult Accompanying Documents Type BF Applied part Gl Class II Double Insulated AC Power IPX1 Drip Proof Vertical SN Serial Number of the product ud Manufacturer Authorized Representative in the European Community C European CE Declaration of Conformity RESmart InH29 are registered trademarks of BMC Medical Co Ltd BMC Medical Co Ltd 2013 1 26 English RESmart Auto User Manual V2 5 Intended Use The RESmart Auto system is a CPAP Continuous Positive Airway Pressure device designed for the treatment of adult Obstructive Sleep Apnea OSA only The RESmart Auto is to be used only on the instruction of a licensed health care professional Your home care provider will make the correct pressure settings according to your health care professional s prescription Several accessories are available to make your OSA treatment with the RESmart Auto CPAP system as convenient and comfortable as possible To ensure that you receive the safe effective therapy prescribed for you use only BMC accessories IMPORTANT Read and understand the entire user manual before operating this system If you have any questions concerning the use of this system contact your home care provider or health care professional Contraindications Studies have shown that the following pre existing conditions may contraindicate the use
7. regulations WARNI NG If you notice any unexplained changes in the performance of the RESmart Auto if it is making unusual or harsh sounds if it has been dropped or mishandled if the enclosure is broken or if water has entered the enclosure discontinue use Contact your home care provider WARNI NG 18 26 English RESmart Auto User Manual V2 5 If the RESmart Auto malfunctions contact your home care provider immediately Never attempt to open the RESmart Auto s enclosure Repairs and adjustments must be performed by BMC authorized service personnel only Unauthorized service could cause injury invalidate the warranty or result in costly damage If necessary contact your local authorized dealer or BMC Medical Co Ltd for technical support and documents Traveling with RESmart When you are traveling the carrying case is for carry on luggage only The carrying case will not protect the system if it is stored as checked baggage Security Stations For convenience at security stations there is a note on the bottom of the RESmart Auto stating that it is medical equipment It may be helpful to bring this manual along with you to help security personnel understand the RESmart Auto Checking the Power Cord If you are traveling to a country with a line voltage different than the one you are currently using a different power cord or an international plug adapter may be required to make your power cord compa
8. B RESmart Auto CPAP System User Manual C 0123 English RESmart Auto User Manual V2 5 Table of Contents Symbols eee CC CCC CC creer rerrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrerrrrrrrrerrrrrrrr rr rrr rrr errr er 1 Intended Use xe gt gt gt e gt e gt gt gt ooo2E n X Xxjrpp xDgggggggggggggggggggggggg ____ gn gm 2 Specifications eee eee Pee CeCe CCPC eee CeCe CeCe Cee eee reer CeCe eee eer eee ee eer eee reer eer ey 3 Warning amp Cautions eee Pee Pe CeCe CCPC CeCe CeCe CeCe eee eee Cee eee ee eee eee eee eee eer re 4 Unpacking the System NN NRK eee C cere reece errr rrr rr rrr rere cree ree ee ee ee ee 5 Available Therapies eee eee eee e eee ee eee re eee e eee eee eee eee eee eee eee eee eee eee eee ee eee 5 System Features DD eee Cee CPC C CCPC CCC CCCP Ce 22mgm nmmggggmgggugguuouuurzgu_ n 6 Glossary OP PC CPPCC e errr o npepaaapoe 3 8D3E3pa2P222222222222m2xmx2x2gg rrr mm n n 7 First Time Setup D p5p 9ppnDnKp2n rpr gDgmgDgggggggggggggggggggggggggggggggggggggggggggggggggggggggggguurza 8 Installing the Filter De eoweoe e n JJDoDDo ooggggaommnnuuuuu mm 8 Device Settings eee eee eee eee eee CeCe eee Cee eee eee CeCe eee Cee cece reer errr ey 10 Assembling the Circuit eee PPC CeCe CeCe CeCe CeCe CeCe eee Cerro ee eee eee 13 Accessories eee PPP POPC CPC CCCP CeCe eee eee eee eee eee eee eee ee eee eee eee ee eee eee eee ee ee 15 Adding a Humidifier eee CeCe Creer errr errr errr rrr
9. F 30 C the temperature of the airflow may exceed 106 F 41 C This could cause irritation to your airway This equipment is not suitable for use in the presence of a flammable anaesthetic mixture in combination with oxygen or air or in the presence of nitrous oxide e If you notice any unexplained changes in the performance of the RESmart Auto if it is making unusual or harsh sounds if it has been dropped or mishandled if the enclosure is broken or if water has entered the enclosure disconnect the power cord and discontinue use Contact your home care provider e To avoid electrical shock disconnect the power cord before cleaning DO NOT immerse the device in any fluids e Contact your health care professional if symptoms of sleep apnea recur e Using the RESmart Auto at an incorrect elevation setting could result in airflow pressures higher than the prescribed setting Always verify the 4 26 English RESmart Auto User Manual V2 5 elevation setting when traveling or relocating Unpacking the System CAUTION Indicates the possibility of damage to the device Tobacco smoke may cause tar build up within the RESmart Auto that may result in the RESmart Auto malfunctioning The use of accessories other than those specified with the exception of cables sold by the manufacturer of the equipment or system as replacement parts for internal components may result in increased emissions or decreased immunity of t
10. X1 Drip Proof Vertical Pressure Range 4 to 20 hPa in 0 5 hPa increments Pressure Stability 4 to 20 hPa 1 hPa Altitude Compensation Manually setting level 0 1 2 Automatic altitude compensation Sound Pressure Level lt 30 dB when the device is working at the pressure of 10 hPa Maximum Flow 3 26 English RESmart Auto User Manual V2 5 Test Pressure hPa 4 8 12 16 20 Average flow at the patient connection 70 1 73 6 75 9 73 0 73 4 port L min Warning amp Cautions CAUTION e This device is restricted to sale by or on the order of a physician WARNI NG Indicates the possibility for injury to the user or the operator e The instructions in this manual are not intended to supersede established medical protocols e This device is intended for adult use only e This device is not intended for life support e CPAP devices have the potential to allow rebreathing of exhaled air To reduce this potential observe the following Use BMC circuit accessories Do not wear the mask and headgear for more than a few minutes while the device is not operating Do not block or try to seal the vent holes in the exhalation port As with most CPAP devices At low CPAP pressures some exhaled gas CO gt may remain in the mask and be rebreathed e Do not use this device if the room temperature is warmer than 86 F 30 C If this device is used at room temperatures warmer than 86
11. and exit the settings menu Assembling the Circuit 6 Assemble the circuit To use the system you will need the following accessories in order to assemble the recommended circuit e Nasal Mask with integrated exhalation port e 6 ft 1 83 m flexible Tubing e Headgear for the mask WARNI NG 13 26 English RESmart Auto User Manual V2 5 If multiple persons are going to use the RESmart Auto e g rental devices a low resistance main flow bacteria filter should be installed in line between the RESmart Auto and the circuit tubing Pressures must be verified by your home care provider when alternate or optional accessories are in place a Connect the flexible tubing to the air outlet on the front of the RESmart Auto b If you are using a mask with a built in exhalation port connect the mask s connector to the flexible tubing If you are using a mask with a separate exhalation port connect the flexible tubing to the exhalation port Position the exhalation port so that the vented air is blowing away from your face Connect the mask s connector to the exhalation port WARNI NG Do not block or otherwise try to seal the air openings vent holes on the exhalation port Explanation of the warning The RESmart Auto is intended to be used with masks and circuits that have an exhalation port designed to exhaust CO2 from the circuit When the RESmart Auto is turned on and functioning properly new air from th
12. bove the RESmart should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the RESmart gt Over the frequency range 150 kHz to 80 MHz the field strengths should be less than 3 V m 25 26 English RESmart Auto User Manual V2 5 Limited Warranty BMC Medical Co Ltd warrants that the RESmart Auto CPAP device shall be free from defects of workmanship and materials and will perform in accordance with the product specifications for a period of one 1 year for main unit and three 3 months for all accessories from the date of sale by BMC Medical Co Ltd to the dealer If the product fails to perform in accordance with the product specifications BMC Medical Co Ltd will repair or replace at its option the defective material or part BMC Medical Co Ltd will pay customary freight charges from BMC Medical Co Ltd to the dealer location only This warranty does not cover damage caused by accident misuse abuse alteration and other defects not related to material or workmanship BMC MEDICAL CO LTD DISCLAIMS ALL LIABILITY FOR ECONOMIC LOSS LOSS OF PROFITS OVERHEAD OR CONSEQUENTIAL DAMAGES WHICH MAY BE CLAIMED TO ARISE FROM ANY SALE OR USE OF THIS PRODUCT SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU To exercise t
13. d immediately WARNI NG The RESmart Auto is powered on for use when the power cord is connected The pressure start stop button turns the blower on off 3 Place the RESmart Auto on a firm flat surface CAUTION Make sure the RESmart Auto is away from any heating or cooling equipment e g forced air vents radiators air conditioners Also make sure that bedding curtains or other items are not blocking the filter or vents of the device Air must flow freely around the device for the system to work properly Display Screen All device settings will appear here Pressure Start Stop Button Use this button to start stop the airflow DO NOT start the airflow until the circuit tubing is connected Heated Humidifier Button Use this button when the optional InH2 Heated Humidifier has been prescribed This button will control the optional heated humidifier s output Follow the instructions of the humidifier Ramp Button When the airflow is turned on use this button to restart the ramp cycle which lowers the airflow pressure and then gradually increases it This will allow you to fall asleep more comfortably When the airflow is turned off use this button to access the patient menu Note The ramp feature is not prescribed for all users 9 26 English RESmart Auto User Manual V2 5 User Buttons These buttons can be used when entering various menus to change some of the RESmart Auto settings RESmart D
14. e RESmart Auto flushes the exhaled air out through the exhalation port When the RESmart Auto is turned off enough fresh air will not be provided through the mask and exhaled air may be rebreathed Rebreathing of exhaled air for longer than several minutes can in some circumstances lead to suffocation This warning applies to most CPAP devices WARNI NG If you are using a full face mask i e a mask covering both your mouth and your nose the mask must be equipped with a safety entrainment valve 14 26 English RESmart Auto User Manual V2 5 Accessories Contact your home care provider for additional information on the accessories available for the RESmart Auto system When using optional accessories always follow the instructions enclosed with the accessories Adding a Humidifier The InH2 Heated Humidifier are available from your home care provider The humidifier may reduce nasal dryness and irritation by adding moisture and heat if applicable to the airflow WARNI NG The RESmart unit should only be connected to the humidifiers or cacessories specified in this Manual Connection of other Items may result in injury or damage to the RESmart unit Adding Oxygen Oxygen may be added at the mask connection Please note the warnings listed below when using oxygen with the RESmart Auto WARNI NG The oxygen supply must comply with the local regulations for medical oxygen WARNI NG Turn the RESmart A
15. el Default setting is 0 disable Reslex 0 12 26 Setting the Delay Off English RESmart Auto User Manual V2 5 h When the optional InH2 Heated Humidifier is used this setting allows the air flow continue for about 15 minutes at very low pressure about 2hPa after RESmart Auto is turned off This will blow off the left vapor and protect the RESmart Auto Default setting is Enable DelayOff Enable Setting the Sensitive i The Sensitive Setting is only effective on Auto CPAP mode The sensitivity of automatically pressure adjusting can be set from 1 soft to 5 hard Default setting is 3 Setting the Date j The current date is displayed and can be modified if needed Note Check and confirm this Date Setting frequently to ensure the usage blog is correct iCode k The iCode consists of six separate codes displayed in the patient menu These codes include Last Day Last 7 Days Last 30 Days Last 90 Days Last 182 Days and Last 365 Days Patient should send these code numbers to your physician when needed Use Days The number of nights the RESmart Auto was used for therapy for more than 4 hours will appear This screen is only for reference Your home care provider may periodically ask you for this information Use Days 0 Exit the Settings m The settings are complete Press the user button to access the SAVE setting and Ramp Button to save all changes
16. g Auto Off d When the mask is removed the RESmart Auto will stop airflow automatically This function is NOT available on certain model Default setting is Enable Auto Off Enable Setting the LCD Light e This setting allows you to adjust the LCD light among Auto On and Off Default setting is Auto Auto LCD light will be turned on when any button pressing and turned off after few seconds On LCD light will be turned ON always Off LCD light will be turned OFF always Light Auto Setting the Alert f This setting allows you to turn on off the patient disconnect alert When a large continuous air leak such as mask removal has been detected in the circuit this setting enables disables the audible alert a beeping sound This setting is only effective when the Auto Off setting is disabled This function is NOT available on certain model Default setting is Disable Alert Disable Setting the Reslex g The Reslex setting displays the Reslex level set by your home care provider This setting allows you to adjust the level of air pressure relief that you feel when you exhale during therapy Your home care provider will have already set a Reslex level If this is not comfortable for you you can increase or decrease the setting The setting of 1 provides a small amount of pressure relief To increase the pressure relief change the setting to 2 This function s NOT available on certain mod
17. he equipment or system Additional warnings and cautions are located throughout this manual as they apply After unpacking the system make sure you have everything shown here No Item Num 1 RESmart Auto CPAP 1 2 Power Cord 1 3 Carrying Case 1 4 User Manual 1 IMPORTANT If any of the above parts are missing contact your home care provider Available Therapies The RESmart Auto CPAP delivers the following therapies CPAP Delivers Continuous Positive Airway Pressure CPAP maintains a constant level of pressure throughout the breathing cycle If your health care professional prescribed ramp for you you can press the Ramp button to reduce the pressure and then gradually increase the pressure to the therapeutic pressure setting so that you can fall asleep more comfortably Auto Delivers CPAP therapy and provides an air pressure no less than the prescription one based on patient s needs Titrate Delivers CPAP therapy while automatically adjusting the pressure level to meet the patient s needs It is used for determining the patient s optimal fixed CPAP pressure this setting was added to the Maintenance Menu and only can be accessed by home care provider 5 26 English RESmart Auto User Manual V2 5 Handle Display Screen User Buttons Humidifier Controller Air Outlet Humidifier Power Handle This handle is for lifting up the system Dis
18. he rights under this warranty contact the local authorized dealers or MANUFACTURER BMC Medical Co Ltd 5 F Main Building No 19 Gucheng Street West Shijingshan Beijing 100043 P R China Tel 86 10 51663880 Fax 86 10 51663880 Ext 810 EU AUTHORI SED REPRESENTATIVE Shanghai International Holding Corp GmbH Europe Eiffestrasse 80 20537 Hamburg Germany Tel 0049 40 2513175 Fax 0049 40 255726 26 26 English
19. ings To order any accessories not included with this system contact your home care provider Note to home care provider Before beginning setup be sure that you have available the RESmart Auto Home Care Provider Setup Instructions Setup instructions are not provided in this manual WARNI NG DO NOT connect any equipment to the RESmart Auto unless recommended by BMC or your health care provider CAUTI ON If the RESmart Auto has been exposed to either very hot or very cold temperatures allow it to adjust to room temperature approximately 2 hours before beginning setup Installing the Filter 1 Install the filters and filter cap CAUTION The foam filter must be in place at all times when the RESmart Auto is operating 8 26 English RESmart Auto User Manual V2 5 a Place the foam filter into the filter area on the back of the RESmart Auto b Attach the filter cap Position the cap so that the small opening on the cap is facing down Insert the cap s tabs into the filter area opening Power Cord 2 Connect the power cord Plug the socket end of the power cord into the AC inlet on the back of the RESmart Auto Plug the pronged end of the power cord into an electrical outlet System status will appear on the RESmart Auto screen IMPORTANT To remove AC power disconnect the power cord from the electrical outlet WARNI NG Inspect the power cord often for any signs of damage Replace a damaged cor
20. isplay Screen User Button User Button Heated Humidifier Ramp Button Button Pressure Start Stop Button IMPORTANT In the Setup Menu the user buttons are used to go to the previous next question or setting and operate as up and down keys to change the settings the ramp button is used to confirm the setting change and the start stop button will allow you to exit the Setup Menu without saving Standby 4 After power on system status will appear on display screen as below Ramp Timer Ramp 10 04 07 Ramp Starting Treatment Pressure Pressure Ramp Starting Pressure The starting pressure after blower is turned on Default setting is 4hPa Treatment Pressure This prescription pressure by physician is the baseline for system automatic adjustment after ramp time Default setting is 7hPa Ramp Timer The ramp time from starting pressure to system automatic adjustment Default setting is 10 minutes Device Settings 5 Verify Change the RESmart Auto settings To start the setup menu press and hold the ramp button until the setup menu appear about 5 seconds when system standby The airflow must be turned OFF 10 26 English RESmart Auto User Manual V2 5 IMPORTANT Pressing the ramp button when the airflow is turned on will lower the airflow pressure if prescribed and then will gradually increase it WARNI NG DO NOT use the RESmart Auto if the display is erratic Contact your home care pr
21. material the relative humidity should be at least 30 Mains power quality should be that of a typical home or hospital Mains power quality should be that of a typical home or hospital Mains power quality should be that of a typical commercial or hospital environment If the user of the RESmart requires continued operation during power mains interruptions it is recommended that the RESmart be powered from an uninterruptible power supply or from a battery If the pressure deviates more than is indicated in the device specification it may be necessary to English RESmart Auto User Manual V2 5 IEC 61000 4 8 position the RESmart further from sources of power frequency magnetic fields The power frequency magnetic field should be measured in the intended installation location to ensure that it is sufficiently low 23 26 English RESmart Auto User Manual V2 5 Guidance and manufacturer s declaration electromagnetic immunity The RESmart is intended for use in the electromagnetic environment specified below The user of the RESmart should make sure that it is used in such an environment Immunity IEC 60601 Compliance Electromagnetic test test level level environment guidance Portable and mobile RF communications equipment should be used no closer to any part of the RESmart including cables than the recommended separation distance calculated from the equation applicable
22. n the RESmart Auto to silence the alert tone Refer to the Troubleshooting Section of the manual for further instructions e Make sure that bedding curtains or other items are not blocking the filter or vents of the RESmart Auto Air must flow freely around the RESmart Auto for the system to work properly If the airflow from the RESmart Auto feels cold reposition the circuit tubing so that it runs under your bed covers to reduce heat loss while you sleep e If interruption of the power supply occurs during system working the audible alert a beeping sound will start and continue Restoration of the power supply will stop the audible alert e After interruption and restoration of the power supply the RESmart Auto will resume with the working status before interruption automatically Routine Maintenance Cleaning the Filter The foam filter should be cleaned at least once every two weeks under normal usage and replaced with a new one every six months CAUTION Operating the RESmart Auto with a dirty filter may keep the system from working properly and may cause damage to the device 1 Remove the filter cap by gently pressing on its bottom 2 Change the filter a Remove the foam filter by gently pulling around the edges of the filter Rinse the filter in a steady stream of running water Squeeze out the water and repeat Air dry the filter on a rack for 8 to 12 hours or in a clothes dryer for 15 to 20 minutes
23. ovider for further instructions IMPORTANT If at any time you wish to exit the setup menu press the Pressure Start Stop Button and the display will go back to the system standby screen Setting the Humidifier a When the optional InH29 Heated Humidifier is used this setting can change the temperature and humidity of airflow between level 0 to 5 Default setting is 3 IMPORTANT Press the Ramp Button to enter change status and press User Buttons to change the setting Press Ramp Button again to confirm the setting Press User Buttons to access the next setting Heater 3 Setting the Altitude b The altitude setting can be changed between level 0 to 2 Default setting is 0 0 less than 2 460 ft lt 750 m 1 2 460 to 4 921 ft 750 m to 1500 m 2 4 924 to 8 202 ft 1501 m to 2500 m over 8 202 ft The airflow pressure may not be accurate Contact your home care provider to have your pressure setting adjusted Altitude 0 IMPORTANT RESmart is already with automatic altitude compensation Even if without setting the altitude RESmart still can deliver proper pressure in any altitude worldwide Setting Auto ON c When the RESmart Auto is standby and wearing mask your deep breath will start airflow automatically This function is NOT available on certain 11 26 English RESmart Auto User Manual V2 5 model Default setting is Enable Auto On Enable Settin
24. play Screen All system settings total operating time and therapy hours will appear here User Buttons These buttons can be used to turn on off the system and change some of the system settings Humidifier Controller This controller turns the InH2 heated humidifier on off and allows the heat setting to be adjusted The humidifier is an optional accessory that may be purchased separately Air Outlet Connect the flexible tubing coaxial 22 mm here Humidifier Power This socket provides the power to the InH2 heated humidifier Medical Product Note bottom AC Inlet Communication Connector Filter Cap amp Filters Medical Product Note For ease at airport security stations there is a note on the bottom of the RESmart Auto stating that it is medical equipment It 6 26 English RESmart Auto User Manual V2 5 may help if you also take this manual with you when you travel AC Inlet Connect disconnect the AC power cord here Communications Connector For clinical use with the Data Management Software Connect the communications cable here Filter Cap amp Filters The foam filter screens out normal household dust and pollens The filter cap is designed to reduce the noise from the RESmart Auto Glossary Apnea A condition marked by the cessation of spontaneous breathing Auto CPAP Adjusts CPAP pressure automatically to improve patient comfort based
25. pplies buildings IEC 61000 3 3 used for domestic purposes 21 26 English RESmart Auto User Manual V2 5 Guidance and manufacturer s declaration electromagnetic immunity The RESmart is intended for use in the electromagnetic environment specified below The user of the RESmart should make sure that it is used in such an environment IEC 60601 Electrostatic discharge ESD IEC 61000 4 2 Electrical fast transient burst IEC 61000 4 4 Surge IEC 61000 4 5 Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 Power frequency 50 60 Hz magnetic field 6 kV contact 8 KV air 2 kV for power supply lines 1 kV for input output lines 1 kV differential mode 2 kV common mode lt 5 Ur gt 95 dip in Ur for 0 5 cycle 40 Ur 60 dip in U7 for 5 cycles 70 Ur 30 dip in U7 for 25 cycles lt 5 Ur gt 95 dip in Ur for 5s Compliance level 6 kV contact 8 kV air 2 kV for power supply lines 1 kV for input output lines 1 kV differential mode 2 kV common mode lt 5 Ur gt 95 dipin Ur for 0 5 cycle 40 Ur 60 dip in Ur for 5 cycles 70 r 30 dip in U for 25 cycles lt 5 Ur gt 95 dip in Ur for 5s 0 3 A m 22 26 Electromagnetic environment guidance Floor should be wood concrete or ceramic tile If floors are covered with synthetic
26. r home care provider for directions on having the RESmart Auto serviced Please have the device s serial number ready when you call Pressing the ramp button does not reduce the air pressure Contact your home care provider Ramp may not have been prescribed for you The RESmart Auto has been dropped into water or fluids have gotten into the enclosure Discontinue use Disconnect the power cord from the AC wall outlet Contact your home care provider for directions on having the RESmart Auto serviced Please have the device s serial number ready when you call 20 26 English RESmart Auto User Manual V2 5 EMC Requirements Guidance and manufacturer s declaration electromagnetic emissions The RESmart is intended for use in the electromagnetic environment specified below The user of the RESmart should ensure that it is used in such an environment Ra e Electromagnetic environment Emissions Test Compliance A omag conme guidance The RESmart uses RF energy only for its internal function RF emissions Group 1 Therefore its RF emissions are CISPR 11 Class B very low and are not likely to cause any interference in nearby electronic equipment The RESmart is suitable for use in CISPR 11 Class B all establishments including domestic establishments and IEC 61000 3 2 those directly connected to the Voltage fluctuations public low voltage power supply flicker emissions Class D network that su
27. tible with the power outlets of the country to which you are traveling Contact your home care provider for additional information 19 26 English RESmart Auto User Manual V2 5 Troubleshooting The table below lists common problems you may have with the RESmart Auto system and possible solutions to those problems If none of the corrective actions solve the problem contact your home care provider Problem Solution s The pressure being delivered feels different Check the altitude setting to be sure it is set to your altitude Change the altitude setting if necessary If the altitude setting is correct contact your home care provider for directions on having the RESmart Auto serviced Please have the device s serial number ready when you call The airflow from the RESmart Auto seems warm Replace or clean the filter Make sure the RESmart Auto is away from bedding or curtains that could block the flow of air around the RESmart Auto Make sure the RESmart Auto is away from heating equipment e g forced air vents radiators The noise level of the RESmart Auto has changed to include unusual or harsh sounds during operation Contact your home care provider for directions on having the RESmart Auto serviced Please have the device s serial number ready when you call The RESmart Auto will not turn on Make sure that the RESmart Auto is plugged into a working outlet Contact you
28. to the frequency of the transmitter Recommended separation distance d 1 2VP G 1 2VP 80 MHz to 800 MHz d 2 3 P 800 MHz to 2 5 GHz 3 Vrms Conducted RF 150 kHz to where Pis the maximum output IEC 61000 4 6 80 MHz power rating of the transmitter in watts W according to the transmitter manufacturer and d Radiated RF 3 V m is the recommended separation IEC 61000 4 3 80 MHzto distance in meters m 2 5 GHz Field strengths from fixed RF transmitter as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol C 24 26 English RESmart Auto User Manual V2 5 NOTE 1 At 80 MHz and 800 MHz the higher frequency range applied NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the RESmart is used exceeds the applicable RF compliance level a
29. uto on before turning the oxygen on Turn the oxygen off before turning the RESmart Auto off Explanation of Warning When the RESmart Auto is turned off but the oxygen flow is still turned on oxygen may accumulate within the RESmart Auto enclosure and create a fire risk Turning the oxygen off before turning the RESmart Auto off will prevent oxygen accumulation in the RESmart Auto and will reduce the risk of fire This warning applies to most CPAP devices WARNI NG Oxygen accelerates fires Keep the RESmart Auto and the oxygen container away from heat open flames any oily substance or other sources of ignition DO NOT smoke in the area near the RESmart Auto or the oxygen container 15 26 English RESmart Auto User Manual V2 5 Routine Use Connecting the Circuit 1 Connect the circuit IMPORTANT Before each use examine the flexible tubing for any damage or debris If necessary clean the tubing to remove the debris Replace any damaged tubing a Connect the mask to the headgear following the instructions included with the headgear b Put on the mask and headgear and breathe normally through your nose The airflow should automatically start when you begin breathing through the circuit If the airflow does not start within four breaths press the pressure start stop button on the top of the RESmart Auto When operating the system with some mask types or some circuit configurations the airflow may