1. 2 Not supplied Product number 4 A Do not connect any electric current to control switch wires Red White Black These wires are only for signal from switches Control Switch A Do not connect Black Red and White wires together UP Black Red STOP DOWN Black White Red Black White Red Black White Red Black White COM COM COM switch switch switch A Do not connect any voltage to the Black Red and White wires Testing Procedure Testing procedure must be done before dismantling or moving the scaffolding or any heavy equipment used for lifter installation purposes 15 Are lifter functions DOWN STOP UP working properly O YES O NO Does the light come ON when lower contact cover is up and connected to the lifter in the normal operating position O YES O NO Can the light fitted be turned ON and OFF by remote control O YES O N Make sure installation layout sheet page 16 has been filled out with all information regarding lifters It is a good idea to mark north and south on the sheet to understand location of lifters Installation Lay out REEL TECH Total Quantity RCUNo A Make sure to install the lifter in unit code order A o o l SerialNo UnitCode Group No If Applicable CO amp CO l l Seiaino ooo G o O Unit Code pe e e l l Group No If Applicable l Serial No Unit
2. 6 ii hi Follow the testing procedure to check the lifter on page 14 i Recess Mounting Plate Example Remote Control Unit RCU 1 D ON button for Lighting D eo Erase the value REEL TECH CO LTD www reeltech co kr 3 e OFF button for Lighting 4 Q To raise lifter 5 qu To lower lifter 6 AD Control button for lowering height D amp Set mode is secured by password please contact local retailer or agency 8 em Group button for group functions 9 e Select switch button for unit code and serial number code 10 E gt To check serial number with unit code qn Mode button is used in conjunction with the following buttons d2 tA Power button for Remote control Functions Remote Control Unit RCU POWER ON OFF Press o button Turning all lights ON OFF Press e and then e buttons to turn ON all light units press P and then Co buttons to turn OFF all light units 11 Individual light ON OFF Select the unit code on the RCU then press to turn ON press CF to turn OFF the light Unit No 5 is an example in the boxes DOWN OPERATION Select the unit code on the RCU and then press 0 To stop press o Otherwise lifter is designed to stop automatically at the preset position or after completion Unit No 1 used as an example in the boxes NOTE To adjust the lowering height see page 13 A Caution e
3. Code Unit Code Group No If Applicable Group No If Applicable Serial No Unit Code Group No If Applicable E l l l Serial No Unit Code Group No If Applicable e e e l l l Unit Code Group No If Applicable Group No If Applicable Serial No Unit Code Group No If Applicable 16 Lighting lifter trouble shooting Trouble Does not turn ON and OFF the light Condition Possible solution gt Does not turn ON and OFF all lights gt Check the supply voltage Check the RCU number gt Does not turn ON and OFF individual light gt Check the unit code gt Check all connections f 4 Check the lamp J b Check the ballast Trouble Lighting lifter does not work UP and DOWN function Condition Possible solution gt Doesn t work all lifters gt Check the supply voltage gt Check the requirement light fixture weight gt Can not control with remote controller Check the RCU number and unit code gt Can not control with control switch Check the all connection gt Can not control with both systems Please contact the nearest purchase retailer for service Trouble During operation lifter suddenly stops Condition Possible solution Lifter stops and does not work a b Lifter is overheated Resume operation after 30 minutes gt Check if suspension cable s
4. Do not hold or press the button continuously it may cause it to reset the lowering height program e Do not lower more than the maximum lowering distance shown on the specifications table on page 18 UP OPERATION Select the unit code on the RCU and then press Q To stop press o Otherwise lifter is designed to stop automatically and turns the light on once it reaches its normal home position Unit No 1 used as an example in the boxes 12 Set the lowering height O Step 1 Select the unit code on the RCU for whichever lifter is being set up H Step 2 Press ED button H Step 3 Press ror button at the desired maintenance position n Step 4 Press and hold the Sey button until shows up on the RCU screen with beeping sound n Step 5 Press Q button raise the fixture about 500mm g Step 6 Press button O Step 7 Press D button to make sure it stops automatically on the preset position check If the lifter has reached its preset height and it needs to be lowered further simply press the D button again and the unit will lower until the ror button is pressed A Do not lower more than the maximim lowering distance shown on the specifications table on page 18 Reset the lowering height The lowering height can be reset at any time if situations change Simply position the lifter at the new height required and follow steps 4 5 6 and 7 of the Set the lowering height above GROUP MODE If lifter grouping has
5. are twisted or tangled During lowering lifter suddenly stops gt Check the required installation height gt Check the automatic lowering stop function Trouble Can not control with remote but it does work with control switch Condition Possible Solution gt Have changed remote control batteries gt Please check with nearest purchase but does not work retailer for service fd zd TEL 61 02 4932 9000 i7 S pecifications Model No Dimension WxDxH Unit mm Unit Net weight KGS Lifting Weight KGS Maximum lowering distance The number of wire Wire O D mm SUS304 7x19 Operating voltage and frequency Maximum rated current of connected equipment Stand by current power Lifter load current in operation Type of motor Model No Dimension WxDxH Unit mm Unit Net weight KGS Lifting Weight KGS Maximum lowering distance The number of wire Wire O D mm SUS304 7x19 Operating voltage and frequencv Maximum rated current of connected equipment Stand by current power Lifter load current in operation Tvpe of motor Hook up Type HSI 18 HDI 25 180 x 174 5 x 227 5 5kg 3 18kg 6 25kg 10 10 1 2 2 0 1 6 220V 420 50 60Hz 16A 16A 0 1A 0 1A 0 8A 0 8A AC AC Slim Type Ssl 10 SDI 20 219 x 244 5x 117 4 53kg 3 10kg 6 20kg 10 8 1 2 1 6 1 2 100 277V 10 50 60Hz 16A 16A 0 2A 0 2A 0 3A 0 3A DC DC Compact Type CSI 12 CDI 15 140 x 140 x 216 2 5kg 3 12kg
6. 3 15kg 15 10 1 2 1 4 1 2 100 277V 10 50 60Hz 16A 16A 0 04A 0 04A 0 3A 0 3A DC DC Heavy Duty Type PSI 20 PSI 30 PDI 35 PDI 50 209 x 215x 268 8 7kg 8 7kg 8 7kg 9 5kg A 20kg 4 30kg omaka 6 50kg 15 15 10 10 1 1 2 2 2 4 2 4 2 0 2 0 220V 2096 50 60Hz 16A 16A 16A 16A 0 1A 0 15A 0 1A 0 15A 0 8A 1A 0 8A 1A AC BLDC AC BLDC All information printed herein is based on data available at the time of printing and is subject to change without notice Confirm specifications contained on lifter unit prior to installation 19 roduct Vjarrantv Serial No Manufacture date Purchase date The term of Duda warranty 1 The product has been produced through strict quality controls and inspections 2 Please fill in blanks in the product warranty and keep it with owner s manual 3 In case of after sales service please contact the company this product was purchased from This warranty is for replacement of faulty products parts only We do not accept consequential damages due to malfunction or failure of our product Please return the product back to place of purchase Warranty conditions are outlined on our general terms of trade Warranty is deemed invalid if Product has been handled and used carelessly Product has been tampered with altered or pulled apart without permission There has been failure to use the correct power supply or specified lowering weight Product has been damaged du
7. Technical User Manual TECHNICAL USER MANUAL MODEL NO O H951 15 LI PDI 50 O HDI 25 O SSI 10 O PSIl 20 LI SDI 20 O PS1 30 O CSI 12 O PPL 35 O CDI 15 Thank you for purchasing our product Please read the manual carefully before installing and operating this product Please keep this manual for future reference as it includes proof of purchase and product warranty SWREEL TECH PLEASE ENSURE YOU READ ALL OPERATION AND INSTALLATION CAUTIONS BEFORE INSTALLING LIFTERS A b AED coat En l 1 i l T Features Operation and Installation Cautions 2894 Product Parts Compact tvpe A Ala PE 5 Hook up tvpe FACE ev Ge ENG TA Dr REO CEBIT EE ORO A 6 Slim type Eee M A ERA NER UE n Heavy duty tVDe ce e 8 Installation B 40 Siancdarc Imetallai necc SU TES 9 Recess mounting plate example 10 Function of Remote Control 142 13 44 Remote Como Euni oo a eomtconsuneeasus JN FU Neton s enmoietcomiro cera Wee Control panel and control switch 14 Tesi aic Orce E eee 15 instalation lay out e AT 16 Lighting lifter trouble shooting 17 Specifica e M ES 18 Warranty A A E E E E E A 19 AN Operation and Installation Cautions IN lifters Do not lower lifter further than the maximum lowering distance shown on the specifications table on page 18 This will possibly damage the lifter and void warranty 1 Always ensure appropriately qualified electrical personne
8. and Single cable Dimension 140mm 124 5mm 152mm 216mm 106mm Must follow local regulations and standards Before installation please check operation and installation cautions on page 2 4 Product Parts Shown below Electric leads to main electric power Active brown Neutral blue Ground Earth conductor green vellow Power cable Control switch leads A Do not connect any voltage Housing unit Slow shaft Upper circular electrical contact Locking device Lower circular electrical contact Suspension wire Na Standard lower cover ilii Cable gland Attachment point for light fixture Single cable Dimension 174 5mm 227 5mm 174 5mm 128 5mm Must follow local regulations and standards Before installation please check operation and installation cautions on page 2 4 Product Parts Shown below Electric leads to main electric power Active brown Neutral blue Ground Earth conductor green yellow Control switch leads Single cable A Do not connect any voltage Upper circular Housing unit electrical contact Slow shaft Locking device Lower circular electrical contact Suspension wire ZN SIA Sh Standard lower cover Is oz Cable gland Attachment point for light fixture Single cable Dimension 13mm 128 5mm 56mm 27mm Must follow local regulations and standa
9. been set up on the RCU only set up by distributor the following procedure needs to be followed Press the mode button and then press and hold down No 7 Group button for 2 3 seconds After this time the RCU will beep and Group 1 will be shown on the RCU screen Choose which group you require by pressing buttons 1 to 4 Only 4 groups are available on the RCU When in group mode all lifters that have been programmed into the group selected will be controlled at once when using the down up light on light off buttons To exit from group mode press the mode button and then press and hold down the No 7 Group button for 2 3 seconds the RCU will beep and the RCU screen will return to normal unit number screen 13 Control Panel System Example Reeltech remote lighting lifter is also designed to be controlled from a hard wired panel Following is a typical layout for a manually controlled system NOTE A Signal cabling Red White Black This is installed onsite to control lifters as a hardwired system Must be rated to a minimum of 300V AC Even though they only carry signal and not voltage Remote Lighting Lifter Control Panel switch wires 1 2 3 4 O ON O ON O ON Q ON Qor Qor Qor Ga 1 1 1 1 1 1 L 1 1 1 i control 1 1 1 1 1 1 1 1 1 1 electric leads t White DOWN to main Black COM electric power brown L Red UP L blue N 1 82 S3 S4 fi a ground earth conductor green yellow
10. e to impact Using the product for different purposes than intended and specified Catastrophes acts of god Improper installation LIGHT MOUNTING SYSTEMS AUSTRALIA ABN 85 087 534 423 TEL 61 02 4932 9000 FAX 61 02 4932 9009 Website www lightmountingsystems com au E mail sales lmsau com HEADQUARTERS 1402 26 SHINDAE RI HAERYONG MYUN SUNCHEON JUNNAM SOUTH KOREA TEL 82 61 723 1127 FAX 82 61 723 4440 Website www reeltech co kr E Mail postmaster reeltech co kr NORTH AMERICA 601 N 44TH AVE SUITE 102 PHOENIX A2 85034 TEL 623 930 0074 FAX 623 930 0045 Website www sportlite com E Mail info sportlite com CENTRAL EUROPE EDUARD KITTENBERGERGASSE 95B 1230 VIENNA AUSTRIA TEL 43 0 1 960 80 88 FAX 43 0 1 960 80 88 80 Website www reeltech eu E Mail office reeltech eu Light Mounting Systems e AUSTRALIA amp NEW ZEALAND LIGHT MOUNTING SYSTEMS AUSTRALIA ABN 85 087 534 423 TEL 61 2 4932 9000 FAX 61 2 4932 9009 Website www lightmountingsystems com au E Mail sales8lmsau com e JAPAN 1 9 18 Yutaka Hakata ku Fukuoka Japan TEL 81 92 432 7708 FAX 81 92 432 7707 Website www ecolight co jp E Mail f_info ecolight co jp e SINGAPORE 11 Kaki Bukit View Singapore 415947 TEL 65 6744 2441 FAX 65 6744 1416 Website www lightcraft com sg
11. l only install remote control Do not operate lifters without the required minimum weight shown on the specifications table on page 18 No weight ET NCheck the specification weight A Check the specification weight 1 Always install lifters in their unit code order Lifters are all numbered If you have purchased 20 lifters they will be numbered 1 to 20 Install No 2 after No 1 then No 3 after No 2 etc Ensure the layout on page 16 is filled out so people operating the lifters in the future know the location of each unit It is advisable to mark North on the layout or entry amp exit locations that exist in the building If the table is too small create your own layout table AN Operation and Installation Cautions IN Always use a licenced electrical contractor for installation work and ensure compliance with Australian and local area standards Do not operate the lifter when suspension wires are tangled or twisted Ensure the mains power is turned off before wiring the lifter and the light It is best to use a multimeter to check before wiring ceiling M MM Make sure that no one is standing underneath lifter while it is operating Remote lighting lifter is not to be used to lift items not specified by the manufacturer Our products are not to be used in place of winches or cranes Do not hold the suspension Do not modify or paint it cable or the light fitting This will void the war
12. ranty while operating and may cause the system to malfunction Moisture High wind l Dust Vibration Corrosive gas Avoid installation where there is high moisture high wind excessive dust excessive vibration and or corrosive gas A Operation and Installation Cautions A Do not put hands or objects between the upper and lower contacts during operation This may cause injury and or malfunction of system Working temperature 15 C to 60 C Do not operate the unit CONTINUOUSLY for more than one round trip Excessive swinging or impact on the lowering wire should be avoided Manual Ensure proper installation and procedures are followed as per this manual REEL TECH CO LTD TEM MODEL pose Use correct power source s as indicated on the unit label Operating the lifter in an unspecified way could cause fire and or may malfunction Supply Cable Damage If supply cable is damaged please return to place of purchase for repairs to be carried out by manufacturer Product Parts Shown below Electric leads to main electric power Active brown Neutral blue Ground Earth conductor green yellow Power cable A Do not connect anv voltage Control switch leads Transmitter Antenna for RCU LED Inner plate Slow shaft Locking device Upper circular electrical contact Suspension wire Lower circular electrical contact Standard lower cover Cable gl
13. rds Before installation please check operation and installation cautions on page 2 4 Product Parts Shown below Electric leads to main electric power Active brown Neutral blue Ground Earth conductor green yellow Single cable A Do not connect anv voltage Upper cover Control switch leads Slow shaft Suspension wire Lower circular electrical contact Locking device Attachment point for light fixture Dimension 167 5mm 195 5mm 283mm 128 5mm Must follow local regulations and standards Before installation please check operation and installation cautions on page 2 4 Standard Installation Lifters must have minimum weights attached as nominated on the specifications table on page 18 before operation of the raising or lowering functions Always have mains power off when installing lifter or light contro switch leads 7 electric leads to main electric power brown blue ground earth conductor green yellow Attach lifter with a hook Connect the main power or a shackle to the lifter 3 4 connect Wt hook up slim link kq type 3kg Please make Sue t e main power is completely poc edd AS when you make electric duty heavy duty type Skg connection between lifter and lighting fixture Attach light fixture to the Make electrical connection lifter Ap CES ABI Press DOWN button to T lower