Home

uSer'S MANuAL r16 - Chubb Home Security

image

Contents

1. Multi Purpose Radio Transmitter 100 283 RPB 1 Button Radio Panic Button 106 040 RSM Radio Smoke Detector 100 001 RKP Radio Keypad NESS R16 CONTROL PANEL USER MANUAL R16 KEYPAD AUDIBLE amp VISUAL FEEDBACK The R16 onboard keypad provides the facility for user level and installer level programming and all user operation and emergency functions The keys are soft touch silicon rubber and are backlit for high visibility Any keypress will turn on the backlighting for 4 minutes BACKLIT LCD DISPLAY FIRE MEDICAL PANIC ONBOARD SIREN FUNCTION BUTTONS PROGRAM ENTER BEEPER OUTPUT OUTPUT TYPE DESCRIPTION Keypad beeper 4 SHORT BEEP Keypad Acknowledge key press ede 3 BEEPS RAPID Keypad Valid entry end of Exit Time 4 e LONG BEEP Keypad Invalid entry 4 94 8 BEEPS RAPID Low battery AC Fail Medical Alarm 4J CONTINUOUS BEEPS Alarm Entry Delay etc Onboard Siren 1 CHIRP Arm Ext I Si xternal Siren output 3 CHIRPS Disarm Onboard Siren DOORBELL TONES The Doorbell has been pressed Onboard Siren SIREN BURST Zone Auto Exclude warning External Siren output Low Volume Onboard Siren SIREN CONTINUOUS Alarm condition Piezo output External Siren output Strobe output STROBE BURST Panel Armed or Disarmed S
2. 15 not available as a Keypad Code and vice versa NESS R16 CONTROL PANEL USER MANUAL 55 PROGRAMMING DOORBELL TO PROGRAM A RADIO DOORBELL ACTION NOTE Program the Ness Radio Doorbell to an available See page 26 User Slot To Program Radio Keys Program Extra Option 5E for that User Slot See page 27 Extra Options For Radio Codes EXAMPLE To program a Radio Doorbell to User Slot 15 In Program Mode 1 Press P10E 15E 2 Press and hold the Radio Doorbell button for 8 seconds 3 Press P25E 5E TO PROGRAM DOORBELL VOLUME ACTION NOTE Enters Program Mode Press Master Code 9 80 The EE sw icon will turn on Press P 5 E is the programming option number for Doorbell Volume The current doorbell tune will be played at the current volume level The display will show a number between 1 amp 4 to show the current volume level 1 lowest 4 highest Factory default is 3 Press 1 4 E E g Press 1E 2E 3E or 4E to select Lowest Low Medium or High volume Each time you select a level the current doorbell tune will play once at that volume Q9 Goto step 2 of any other programming option The J ocean icon will turn off when you or press P E to exit program mode exit program mode E NESS R16 CONTROL PANEL USER MANUAL PROGRAMMING DOORBELL Je TO PROGRAM DOORBELL TUNE ACTION NOTE 1 See step 1 of Doorbell Volume Programmin
3. by entering a valid keypad code followed by the E button or press the OFF button on a valid Radio Key To check the cause of the alarm you can view the event memory as shown on page 18 In the event of an alarm the strobe light will continue to flash until the panel is reset by the keypad or radio key otherwise it will time out after 11 hours If mains power is disconnected the panel will reset the strobe light output after 1 hour to conserve the backup battery EN NESS R16 CONTROL PANEL USER MANUAL OPERATION SUMMARY OPERATION XEM User Code E The panel must be in Shortcut method If enabled by your installer a Disarmed state first E Press the ON button once DISARM To Disarm and or reset alarms User Code E MONITOR MODE User Code E The panel must be in Shortcut method If enabled by your installer Press ON button twice a Disarmed state first E within 4 seconds MEDICAL function only if enabled Radio Key Panic will 90 44 CxO CxO by your installer Both keys together Keypad Panic must be enabled by your installer KEYPAD DURESS 9 User Code E Radio Key Duress will function only if enabled Keypad Duress should only To Disarm and report a Duress Alarm add the by your installer used by arrangement with digit 9 before your User Code when Disarming your monitoring station This will function only if enabled by your installer EXCLUDING ZONES E
4. displayed one digit at a time The S sw icon will turn off when you exit program mode NOTE When in Program Mode The 8 os icon is on The existing time will be displayed one digit at a time The factory default time is 60 seconds The new time will be displayed one digit at a time The 88 sw icon will turn off when you exit program mode NESS R16 CONTROL PANEL USER MANUAL EJ SPECIFICATIONS RADIO ZONES 16 HARDWIRED ZONES 1 operates in series with zone 16 HARDWIRED TAMPER ZONES 1 RADIO COMPATIBILITY Ness supervised amp encrypted radio devices DIALLER FORMAT Contact ID Format Audible Voice Format ON BOARD KEYPAD Backlit programming amp user functions LCD DISPLAY High contrast icon display PLUG PACK 220 240V AC 50 60 7 output 17V AC 300mA QUIESCENT CURRENT DRAW BUILT IN BACKUP BATTERY 10 mA in power save mode if mains is off 12 volt 0 8 Amp hour sealed lead acid DYNAMIC BATTERY TEST Every Hour and on arming disarming FUSES Siren Output 2A Auto reset Strobe 1 5A Auto reset Piez Output 500mA Auto reset Built in Piezo 500mA Auto reset SIREN OUTPUT 1 x 8 Ohm horn speaker max ON BOARD PIEZO SIREN 110 dB PIEZ RESET OUTPUT 12V DC 300mA max STROBE OUTPUT 12V DC 1 strobe light max DIMENSIONS 210 w x 145 h x 40 d mm EJ NESS R16 CONTROL PANEL USER MANUAL RIS D
5. manual RK4 RADIO KEY RDB RADIO RK1B RADIO Press and hold DOORBELL PANIC Panic for 8 Press and hold Press 3 times seconds for 8 seconds EXTRA OPTIONS FOR RADIO CODES Each User Slot has five Extra Options which control the behaviour of Radio Keys and the Radio Doorbell transmitter The Extra Options are 1E Panic The Panic Button will trigger the Panic alarm default 2E Duress The Panic Button will trigger the Duress alarm 3E Medical The Panic Button will trigger the Medical alarm 4E Ignore Panic Disables Panic Button on radio keys 5E Doorbell The Panic Button will sound the R16 doorbell feature Each User Slot is defaulted for Extra Option 1E trigger Panic The Extra option for a user code slot can be programmed after a radio key has been programmed to that slot PROGRAMMING SEQUENCE FOR EXTRA OPTIONS 1 Press P User Slot option number 12 25 E e If a Radio Key is programmed to the User Slot the RADIO icon will be on Icons 1 5 show which Extra Option is currently selected 2 Press 1 5 E e This selects a new Extra Option EXAMPLE When programming a Radio Doorbell the User Slot must be set for Doorbell or the Panic alarm will be triggered when the doorbell is pressed In this example a Radio Doorbell has been programmed to User Slot 15 To program the Extra Option for User Slot 15 in program mode press P25E 5E NESS R16 CONTROL PANEL USER MANUAL 27 PROGRAMMING KEYPAD C
6. will be on steady Press and hold the PANIC button for at least 8 seconds on the Radio Key to be programmed If the Radio Key was successfully programmed you will hear beep beep 3 beeps See Extra Options For Radio Codes on the next page to program the behaviour of the Radio Key s Panic button Or skip to step 6 to leave the factory default Panic button triggers Panic Alarm Go to step 2 of any other programming option or press P E to exit program mode TO DELETE RADIO KEYS To delete a Radio Key press P10E select the User Slot to delete 2E 15E then press P10E again EXAMPLE To delete the Radio key programmed on User Slot 2 Press P10E 2E P10E NOTE Enters Program Mode The 8 sw icon will turn on P10E is the option number for programming Radio Keys Choose a User Slot to program a Radio Key Enter a user slot number from 2 to 15 followed by the E button This transmits the Learn message to the R16 panel A long beep means the Radio Key is already programmed to another User Slot The 8 sw icon will turn off when you exit program mode The panel must be in Program Mode EJ NESS R16 CONTROL PANEL USER MANUAL PROGRAMMING RADIO KEYS HOW TO SEND THE LEARN MESSAGE PORTABLE TRANSMITTERS This table shows the method for sending the programming Learn message for compatible Ness transmitters RKP RADIO KEYPAD Insert the battery or consult the Radio Keypad
7. EL USER MANUAL OPERATION EMERGENCY FUNCTIONS gt DURESS ALARM IMPORTANT NOTE Your installer must program the R16 to enable Radio Key Panic to act as the DURESS alarm This means Radio Key Panic will no longer be available To generate a DURESS alarm using the keypad add the digit 9 in front of your code when disarming 9 User Code E The Keypad Duress function is disabled by default and must be enabled by your installer The DURESS alarm can be used to send a silent alarm to the Central Station that you are being forced to disarm the panel against your will That is you are disarming under duress To Disarm and send a DURESS alarm prefix your User Code with the digit 9 when Disarming If enabled by your installer to generate a DURESS alarm using a Radio Key press and hold the Radio Key PANIC button for at least 4 seconds DURESS ALARM IS NORMALLY NOT ENABLED TO ENABLE THE DURESS FUNCTION CONSULT YOUR INSTALLER DURESS ALARMS CAN ONLY BE USED IF YOUR SYSTEM IS MONITORED BY A CENTRAL STATION THE DURESS ALARM DOES NOT SOUND ANY SIREN OUTPUTS AND CAN ONLY BE REPORTED BY DIALLER TO YOUR CENTRAL STATION E NESS R16 CONTROL PANEL USER MANUAL OPERATION EMERGENCY FUNCTIONS FIRE ALARM To generate a FIRE alarm using the keypad press The FIRE Alarm cannot be generated and hold the FIRE key left hand star key for by a Radio Key at least 2 seconds CeO
8. It is the responsibility of a qualified Installer to ensure correct configuration to the telephone network 2 Erratic or reduced radio range as detailed in the manufacturer s specifications Ness radio based products are sophisticated low power devices however the presence of in band radio signals high power transmissions or interference caused by electrical appli ances e g computers televisions etc MAY reduce the range performance Whilst such occurrences are unusual they are possible none the less If a problem such as this is encountered and the performance is unsatisfactory the installer of the product should be contacted immediately 3 Unauthorised tampering physical damage electrical interruptions such as mains failure electrical spikes or lightning Ness Security Products is not an insurer of either property or safety of the user and limits its liability for any loss or damage including incidental or consequential damages to Ness original selling price There are no warranties expressed or implied which extend beyond the description on the face hereof Ness Security Products recommend that the system is tested weekly to confirm reliable operation
9. MADEN A AUSTRALIA o INEZ LES Ness R16 Radio Control Panel OPERATION amp PROGRAMMING MANUAL REV 1 Head Office E Briere Ness Security Products Pty Ltd Company ABN 28 069 984 372 n 4 167 Prospect Hwy l Seven Hills NSW 2147 Australia Security Products Ph 61 2 8825 9222 Admin Fax 61 2 9838 8508 ness ness com au WWW ness com au SYDNEY Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au MELBOURNE MAD E Ph 03 9875 6400 Fax 03 9875 6422 IN nessmelb ness com au AUSTRALIA pate Ph 07 3399 4910 Fax 07 3217 9711 nessbris ness com au v PERTH Ph 08 9328 2511 Fax 08 9227 7073 nessper ness com au Australia s largest designer ADELAIDE and manufacturer of Ph 08 8152 0000 Fax 08 8152 0100 high quality security products adelalde noss comiats R16 USER S MANUAL REV 1 March 2008 Document Part Number 890 319 For products 100 690 R16 Control Panel APPROVALS EMC COMPLIANCE EN 50130 4 1996 Part 4 Electromagnetic compatability Electrostatic Discharge Radiated RF Immunity Electrical Fast Transient burst Surge Immunity Conducted RF Immunity Voltage Dips and Interruptions Mains Supply Variations AS NZ CISPR 22 2002 Class B Electromagnetic Radiation Terminal Disturbance Voltage EN61000 6 3 2001 Harmonic Current Emissions Voltage fluctuations and Flicker TELECOM TBR21 EU PTC200 NEW ZEALAND TELECOM AS ACIF S002 AUSTRALIA SAFETY EN60950 2000 inc Co
10. MED The system is On and ready to detect intrusion DISARMED The system is Off This is the normal mode when the premises are occupied Day Zones and 24 Hour Zones such as external siren tamper if used are active DAY MODE The system is Disarmed and a zone or zones have been setup to create an alarm when activated Often used as a doorway alert in a shop MONITOR MODE Allows the system to be partially Armed For example in a house to allow all perimeter zones doors and windows to be Monitored armed at night 24HR ZONES Zones that have been setup to be active in any mode Usually used for Tamper switches and Panic buttons DOORBELL The doorbell can be triggered using the optional Ness Doorbell transmitter The doorbell function has adjustable volume and selectable chime settings Operates in any panel mode ALARMS DEFINITION Alarms may be caused by A zone has been triggered while Armed A Tamper has been triggered A PANIC button has been triggered All of these may cause your sirens and strobe to operate Various visual indications relevant to the alarm will be retained in the memory If this occurs Disarming your control panel will reset the alarm The cause of the alarm can be identified by entering the Alarm Memory Mode as described on page 18 RESETTING ALARMS To stop the siren s or to reset the strobe light if it is still flashing if installed reset the panel using the keypad
11. ODES CD 2 9 4 5 6 C2 8 TO PROGRAM KEYPAD CODES 5 0 5 ACTION NOTE Enters Program Mode Press Master Code 9 Q l The proram ICON will turn on Press P 11 25 E The existing code will be displayed one digit at a time Enter the option number for the Keypad Code you are programming Press J JJ You will hear one beep on the first entry of the new code and three beeps when NEW CODE NEW CODE E the code is verified Enter the new code twice for verification The new code will be displayed one EXAMPLE To program Keypad Code 2 to be 1234 coat Press P12E 1234E 1234E Goto step 2 of any other programming option The SS wow icon will turn off when or press P E to exit program mode you exit program mode TO DELETE KEYPAD CODES delete a Keypad Code enter the MEMORY button The panel must be in Program Mode in place of the code EXAMPLE To delete the Keypad Code 2 Press P12E MEMORY E NOTES ON PROGRAMMING KEYPAD CODES User Code 1 Master Code can be changed but it can not be deleted The MEMORY E sequence simply reverts User Code 1 back to factory default of 123 Open Close reports if enabled by your installer are identified by user number if the control panel is central station monitored Shortcut arming ARM E if enabled is identified to the central station as User 25 Keypad Codes can be 3 to 6 digits in length Codes beginnin
12. TROBE CONTINUOUS Alarm condition Arm disarm chirps must be enabled by your installer EN NESS R16 CONTROL PANEL USER MANUAL R16 KEYPAD KEYPAD DISPLAY IN OPERATING MODE DISPLAY OFF ON pes FLASHING gt one is seale one is unseale one alarm ZONES 1 16 z led Z led Zone al Y Not ready to arm unsealed READY zones or system faults Ready to Arm f ARMED Disarmed Armed S unos Disarmed Monitor Mode q MAINS Norma Mains Power is off The panel s backup BATTERY Norma battery is low ALARM Norma Memory Mode selected New alarms i MEMORY y Mode selecte ew alarms in memory e EXCLUDE Norma Zones are excluded TAMPER Norma Tamper alarm Lis Indicates that a Radio Key or B RADIO Norma Receiving radio signal other radio device has a low battery A Phone line fault or LINE Norma Dialler is on line failure to communicate PROGRAM Norma User Program Mode Installer Program Mode The flashing RADIO fault icon could be indicating that the radio key device has either low battery or supervision failure or other radio related problems The numeric display 1 15 will show which device is sending the signal See page 18 How to view memory See page 19 The table KEYPAD DISPLAY IN MEMORY REVIEW MODE provides further detail NESS R16 CONTROL PANEL USER MANUAL ES OPERATION OPERATING MODES The Ness R16 will operate in one of the following modes AR
13. Tamper Panel Siren TAMPER Tamper 4 failed attempts TAMPER PROGRAM Radio Jamming RADIO Radio Substitution RADIO Radio Key Low Battery RADIO BATTERY 2 15 Radio Key Panic Medical RADIO EXCLUDE Detector Tamper RADIO TAMPER 1 16 RADIO BATTERY 1 16 Detector Low Battery Detector Supervision Fail RADIO 1 16 Pendant Supervision Fail RADIO MONITOR 1 15 MEMORY REVIEW EXAMPLES ALARM MEMORY Panel was Disarmed ALARM MEMORY Panel was Armed ALARM MEMORY Zone 3 alarm ALARM MEMORY 5 BATTERY Low Battery from radio device 1 NESS R16 CONTROL PANEL USER MANUAL 19 MONITORING CENTRAL STATION MONITORING I I I MONITORED TELEPHONE LINE MONITORING PREMISES f STATION AUDIBLE MONITORING 1 I I 1 l 1 i MONITORED i TELEPHONE LINE I ANY TELEPHONE PREMISES NOTE The R16 can be monitored by Central Station or by Voice Dialling to a private phone but not by both simultaneously Any telephone numbers programmed in options P70E amp P71E must be erased to allow the Voice Dialling telephone numbers to work Ask your installer CENTRAL STATION MONITORING The R16 control panel has an on board digital dialler which can send detailed alarm messages to a Central Monitoring Station The digital messages can include information
14. The Keypad Fire alarm function is disabled by default and must be enabled by your installer The FIRE alarm sounds the siren outputs using the Fire siren sound and the dialler reports a fire alarm gt MEDICAL ALARM To generate a MEDICAL alarm using the keypad IMPORTANT NOTE Your installer must press and hold the MEDICAL key right hand star key program the R16 to enable Radio Key Panic for at least 2 seconds to act as the MEDICAL alarm This means Radio Key Panic will no longer be available If enabled by your installer to generate a CeO CeO MEDICAL alarm using a Radio Key press and hold the Radio Key PANIC button for at least 4 seconds The Keypad Medical alarm function is disabled by default and must be enabled by your installer The primary purpose of this alarm is to report a MEDICAL alarm to your central station The keypad beeper sounds 8 rapid beeps to indicate that the Medical alarm has been triggered NESS R16 CONTROL PANEL USER MANUAL OPERATION DOORBELL gt DOORBELL If a Ness Radio Doorbell has been installed IMPORTANT NOTE The R16 can be programmed simply press the button once to allow Radio Key Panic to act as the DOORBELL This means Radio Key Panic will no longer be available If enabled by your installer to sound the ess s Doorbell press and hold the Radio Key i PANIC button for at least 4 seconds The doorbell tune is heard through the R16 onboard si
15. Zones can be Excluded when the panel is disarmed then press Zone No E Zone No E Enter the zone numbers to be Excluded E To exit Exclude mode VIEW MEMORY 8 View Memory can be used 1 6 press when the panel is disarmed repeatedly to display the last 20 events E To exit Memory mode DOORBELL RDB Radio Door Bell Depending on availability in the regional frequency Note Monitor Mode arming will be ignored if no monitor zones are programmed NESS R16 CONTROL PANEL USER MANUAL EN OPERATION To Arm the system using the onboard keypad press ARM followed by a valid user code followed by the E key User Code E or CARM The Arming Shortcut is enabled by default this allows arming without having to enter your user code The Arming Shortcut can be disabled by your installer The control panel must be armed to enable detection zones Arming the panel starts the exit delay timer All zones are inactive during this time and become fully armed once the exit delay time expires End of exit delay is signalled by 3 beeps from the keypad beeper The factory default exit delay time is 60 seconds This can be changed if necessary see the programming section in this manual The panel must initially be in the disarmed state and not in Program Monitor Memory or Exclude modes To Arm the system using a Radio Key press the ON button If Siren C
16. aboutthe zone or zones which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who Arm and Disarm the system For further information about alarm monitoring contact your dealer NESS VOICE DIALLING The dialler sends alarm reports to a private telephone mobile telephone or fixed telephone using Voice Dialling Telephone numbers 1 and 2 POOE PO1E ENABLING VOICE DIALLING Voice Dialling Format is enabled simply by programming the Voice Dialling phone number options POOE and See side note Central Station Monitoring must be disabled to enable Voice Dialling OPERATION The word ALARM is repeated for 30 seconds until the alarm is acknowledged see below If the alarm is not acknowledged the telephone number will be redialled ACKOWLEDGING THE ALARM The person receiving the call can acknowledge the alarm by pressing the key on their telephone Press the key for 2 seconds during pauses in the audible message On mobile phones press the key in short bursts Many mobile phones enter sub menus if the key is pressed continuously EJ NESS R16 CONTROL PANEL USER MANUAL REMOTE OPERATION AUDIBLE FEEDBACK J 3 BEEPS Valid command user code 4 L 4 LONG BEEP Invalid command or user code try again NOTES If the R16 does not receive remote commands for periods longer than 60 seconds it will assume that the call
17. ate Installed INSTALLATION RECORD Doorbell Volume Installation Company Telephone Doorbell Tune Monitoring Company Telephone Description Entry Delay Time Seconds Exit Delay Time Description Seconds USER SLOT USER S NAME User Code 1 Master Code USER TYPE KEYPAD RADIO CODE User Code 2 User Code 3 User Code 4 User Code 5 User Code 6 User Code 7 User Code 8 User Code 9 User Code 10 User Code 11 User Code 12 User Code 13 User Code 14 User Code 15 NESS LIMITED WARRANTY Ness Security Products Pty Ltd warrants its products to be free from manufacturing defects in materials or workmanship for the war ranty period as detailed in Ness Terms and Conditions of Sale and all other obligations detailed in those Terms and Conditions Whilst Ness Security Products the manufacturer is accredited to ISO9001 and all possible care and diligence has been applied during manufacture to ensure the reliable operation of this unit there are various external factors that MAY impede or restrict the operation of this unit in accordance with the product s specification These factors include but are not limited to 1 Failure to communicate to the monitoring company due to a telephone service provider s line fault or due to the incorrect configura tion of the telephone Product to the Telephone Network
18. e light output will flash and the onboard siren will chirp three times to indicate successful disarming The factory default entry delay time is 20 seconds This can be changed if necessary see the programming section in this manual If you make a mistake in entering your code press the E button and try again Five incorrect code attempts will cause an alarm E NESS R16 CONTROL PANEL USER MANUAL OPERATION EMERGENCY FUNCTIONS PANIC ALARM To generate a Keypad PANIC alarm using the keypad press both star keys together for 2 seconds y N 31 FIRE PANIC MEDICAL Both keys together The Keypad Panic function is enabled by default and can be disabled by your installer The keypad PANIC function sounds the onboard siren and the external siren outputs The sirens will reset when the Siren Reset Time has expired factory default is 5 minutes A Panic report will be sent by dialler if your system is monitored by a Central Station If PANIC reports have been enabled by your installer To generate a PANIC alarm using a Radio Key press the and hold the Radio Key PANIC button for at least 4 seconds The Radio Key Panic function will only function if enabled by your installer PANIC cannot be used while the panel is in Program Memory or Exclude mode Note Your installer may have installed a separate PANIC button To activate the panic alarm simply press that button NESS R16 CONTROL PAN
19. g or if already in program mode continue to step 2 P6E is the programming option number Press P 6 E e for Doorbell Tune The current doorbell tune will be played and the display will show the tune number from 1 to 9 The factory default tune is number 3 Press 1 9 E AVAILABLE TUNES E g Press 1E through 9E to find the tune you prefer Westminster Westminster 4 notes only Ding Dong Ding Dong repetitive Star Spangled Banner Fur Elise Home Sweet Home Greensleeves Chime OOnNOoahRwWP Goto step 2 of any other programming option The 8 rosen icon will turn off when you or press P E to exit program mode exit program mode See page 16 for Doorbell Operation NESS R16 CONTROL PANEL USER MANUAL EJ PROGRAMMING RADIO KEYS The R16 will accept up to 14 Ness Radio Keys to be used for remote control wireless Arming Disarming and Panic functions Radio Keys are programmed to one of the 15 User Slots with the easy to use radio Learn mode A User Slot can hold either a keypad code or a radio key code not both User Code 1 the master Code is always a keypad code TO PROGRAM RADIO KEYS ACTION Press P Master Code E Press P 1 0 CE Numbers 2 to 15 on the display will show which User Slots already contain Radio Keys if any Press 2 15 E The chosen User Slot number will be flashing User Slots with Radio keys already programmed
20. g with 0 zero can be programmed but they will not operate the panel this is an alternative method for disabling user codes The MEMORY E function is the recommended method of deleting user codes All codes must be unique to each other Codes are rejected if already used Some codes that are similar to existing codes may also be rejected NESS R16 CONTROL PANEL USER MANUAL PROGRAMMING TIMERS TO PROGRAM ENTRY DELAY TIME ACTION Press P Master Code E Press P 2 6 E P26E is the option number for Entry Delay Time Press NEW TIME E Enter a new entry delay time from 1 to 99 seconds EXAMPLE To make the entry delay time 25 seconds Press P26E 25E Go to step 2 of any other programming option or press P E to exit program mode TO PROGRAM EXIT DELAY TIME ACTION See step 1 of Entry Delay programming or if already in program mode continue to step 2 Press P Q2 E P28E is the option number for Exit Delay Time Press NEW TIME E Enter a new exit delay time from 1 to 99 seconds EXAMPLE To make the exit delay time 50 seconds Press P28E 50E Go to step 2 of any other programming option or press P E to exit program mode NOTE Enters Program Mode The 8 sw icon will turn on The existing time will be displayed one digit at a time The factory default time is 20 seconds The new time will be
21. hirps have been enabled by your installer the strobe light output will flash and the onboard siren will chirp once to indicate successful arming Note If the panel is already in alarm you must first silence the alarm before you can arm At the end of the exit time all zones should be Sealed If any are Unsealed the onboard siren and the external siren if installed will sound a lower volume tone for 2 seconds as a warning that those zones have been automatically excluded For maximum security you should return disarm the panel check the premises and then Arm again Continual warnings could mean that a detector is faulty and may have to be manually excluded If the auto exclude option is disabled by your installer and a zone is unsealed at the end of exit time the siren will sound for 5 minutes 5 minutes is the factory default siren duration E NESS R16 CONTROL PANEL USER MANUAL gt MONITOR MODE OPERATION Ensure the system is disarmed before attempting to arm in Monitor Mode User Code E Ceara The Monitor Mode Shortcut is enabled by default this allows arming of Monitor Mode without having to enter your user code Monitor Mode Shortcut can be disabled by your installer Monitor mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored while you are at home Your installer must program which zones wi
22. is finished and it will hang up SUMMARY OF TELEPHONE COMMANDS 0 PREPARE TO RECEIVE COMMANDS User Code VERIFIES THE USER 1 4 ARM 2 DISARM HANG UP REMOTE TELEPHONE ARM DISARM The R16 can be armed and disarmed remotely using a standard fixed or mobile telephone To maintain panel security remote operations can only be activated after entering a valid user code To operate the R16 by telephone you need a DTMF capable telephone a valid User Code and you must know the Telephone number of the line to which the R16 is connected Remote Operation is disabled by default and must be enabled by your installer before it can be used SEQUENCE OF OPERATION 1 Phone the R16 telephone number and listen for the required number of double rings and then hang up 2 Call the number again within 60 seconds 3 The R16 will answer the second call immediately sound a beep for 2 seconds then after a pause it will sound a lower frequency tone The R16 is now ready to receive telephone commands 4 Pressthe 0 button on the telephone This tells the R16 that telephone commands will follow 5 Now enter a valid User Code followed by the st button The R16 will respond with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again 6 Enter the command to arm or disarm the panel See Summary Of Telephone Commands 7 Press to finish This tells the R16
23. ll be active in Monitor mode The panel must initially be in the disarmed state and not in Program Monitor Memory or Exclude modes To arm in Monitor Mode using a Radio Key press the ON button twice within 4 seconds If Siren Chirps have been enabled by your installer the strobe light output will flash and the onboard siren will chirp once to indicate successful arming in Monitor Mode Entry and Exit delay timers operate as normal in Monitor Mode If an alarm occurs while in Monitor mode entering User Code will silence the alarm This will also Disarm the panel so remember to enter monitor again if needed Using the optional Radio Keys you can enter Monitor Mode by pressing the ON button twice within 4 seconds NESS R16 CONTROL PANEL USER MANUAL OPERATION To Disarm the system using the onboard keypad enter a valid user code followed by the E key User Code E Sirens and strobe output if running will be reset on disarming When you enter the protected premises through a delay zone the keypad will sound continuous beeps as a reminder to disarm The panel must be disarmed before the entry delay time expires otherwise the alarm will sound If using a Radio Key you can disarm from outside the premises without having to enter any protected zones To Disarm the system using a Radio Key press the OFF button If Siren Chirps have been enabled by your installer the strob
24. ren The doorbell volume and the tune can be set by the user See pages 24 amp 25 for doorbell volume and doorbell tune programming If a Ness Radio Doorbell has been installed simply press the button once The R16 can also be programmed to operate the doorbell from the Panic button of Ness radio keys Note that in this case the R16 cannot receive Panic alarms from radio keys E NESS R16 CONTROL PANEL USER MANUAL OPERATION EXCLUDING ZONES P EXCLUDING ZONES EXCLUDING ZONES To EXCLUDE zones the R16 must be in the disarmed mode Press User Code E or E The 02 EXCLUDE icon will turn on Enter the zone number of the zone s to be excluded 1 16 Zone No E Zone No E etc The zone light of each Excluded zone will turn on Press E to exit Exclude mode P The Q EXCLUDE icon will flash continuously until the panel is next disarmed If a detector becomes faulty and cannot be sealed when arming the panel that zone can be Excluded so that it does not cause alarms When zones have been Excluded the EXCLUDE icon flashes continuously while the panel is Disarmed and also when Armed Zones can only be excluded while the panel is disarmed Zone Exclude is not permanent Excluded zones are automatically Included next time the system is disarmed Zones can be manually included by the same method as Excluding Simply use the ZONE NUMBER sequence to
25. to hang up Also hang up your telephone NESS R16 CONTROL PANEL USER MANUAL ER PROGRAMMING Various system options can be programmed by the user These options can only be accessed from Program Mode To ENTER Program Mode User Codes or Radio Keys can be added or deleted Up to 15 keypad user codes or P Master Code E 14 Radio Keys or a mixture of both can be programmed Entry and Exit timers can be changed if necessary between 1 and 99 seconds To EXIT Program Mode The Doorbell Tune and Volume can be programmed P E For all other programming changes ask your installer The panel will automatically exit Program Mode if no buttons are pressed for The factory default 4 minutes Master Code is 123 22 NESS R16 CONTROL PANEL USER MANUAL PROGRAMMING PROGRAMMING OPTIONS TABLE OPTION NUMBERS P5E DESCRIPTION DOORBELL VOLUME DEFAULT Level 3 PeE DOORBELL TUNE ENTRY DELAY TIME Tune 3 20 seconds EXIT DELAY TIME 60 seconds NUMAE l USER SLOT 1 MASTER KEYPAD CODE USER SLOT 2 USER SLOT 3 USER SLOT 4 USER SLOT 5 USER SLOT 6 USER SLOT 7 USER SLOT 8 USER SLOT 9 USER SLOT 10 USER SLOT 11 USER SLOT 12 USER SLOT 13 User Slots 2 to 15 can store either a Keypad Code or a Radio Key not both If a user Slot is programmed as a Radio Key using option P10E then that slot is USER SLOT 14 USER SLOT
26. turn OFF the zone icons to be Included NESS R16 CONTROL PANEL USER MANUAL NESSRIGCONTROLPANEL USER Manua EEA OPERATION VIEW MEMORY gt VIEWING MEMORY Q Press User Code E OF P The M MEMORY icon will turn on Press Press Press Press E to exit Memory mode The R16 control panel stores a comprehensive event memory including Arming Disarming Low Battery Mains Fail and Alarms The memory is constantly upgraded and the last 20 events are always available for viewing This memory display can only be selected while the panel is in the Disarmed state The most recent event will be displayed k The next most recent event will be displayed and 50 on up to the last 20 events TO CLEAR THE MEMORY ICON The MEMORY icon on the LCD display flashes continuously when an alarm has occurred as a reminder to view the alarm memory The MEMORY icon stops flashing after the memory is viewed as shown above The MEMORY icon is automatically cleared next time the panel is Armed and on entry to program mode E NESS R16 CONTROL PANEL USER MANUAL OPERATION VIEW MEMORY KEYPAD DISPLAY IN MEMORY REVIEW MODE EVENT DISPLAY ICONS Arm ARMED Disarm blank Auto Exclude Zone EXCLUDE 1 16 Mains Fail MAINS Panel Panic Medical Fire EXCLUDE Battery Fail BATTERY Line Fault LINE Dialler Call Fail LINE Zone Alarm 1 16
27. untry Deviations Safety of Information Technology Equipment AS NZ3260 1993 incl AMDTS 1 2 3 amp 4 TS001 1997 ACA Australian Communications Authority NESS SECURITY PRODUCTS Australian Communications Authority TELECOMMUNICATIONS COMPLIANCE COPYRIGHT NOTICE All rights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2008 Ness Security Products Pty Ltd ABN 28 069 984 372 CONTENTS INtrOCUCTION iioii eode tec i Ae 4 Compatibility iis 1 2 cinere cedere deeds 5 R16 Keypad aed eat maf 6 7 Operation nto n e RE E 8 Operation S MMA 2 in E li D ERO UG 9 Arming terre reer rarer ep e E EO ER 10 Monitor Mode ete REPRE RES 11 Disarming tere rene Pee 12 Panic Alarms itecto rre ec Ge rug ere deh A eels 18 Duress Alarm i ite ee peo ise 14 Fite AIarri ior c tn didit bat eus 15 Medical Al arrri 3 5 x PL e ete de rbi ig ced 15 Radio Doorbell tdt dde 16 Excluding Zones negent al Lr E 17 View ee bed ite bte s 18 19 Monitoring Operatii nersidin an eai 20 Remote Operation b
28. volume audible warning The R16 also has Siren Piezo and Strobe outputs for additional hardwired noisemakers The R16 has anumber of sophisticated power saving features designed to provide at least 48 hours service running on the backup battery alone This includes one full alarm condition with sirens strobe and dialler The built in dialler uses Contact ID format for central station monitoring as well as audible monitoring to any telephone The user can also dial into the system for remote arming and disarming over the telephone line RADIO KEYS RADIO DOORBELL PLUGPACK Supplied Ce CL PHONE LEAD Supplied ZONE INPUT HARDWIRE EXTERNAL SIREN OUTPUT STROBE OUTPUT TAMPER INPUT INTERNAL PIEZO OUTPUT NESS R16 CONTROL PANEL USER MANUAL COMPATIBILITY The Ness R16 supports all Ness radio devices as shown below All late model Ness transmitters send encrypted transmissions to prevent eavesdropping and substitution Ness fixed transmitters can send a regular supervision signal which the R16 monitors to ensure system security 100 067 RK4 4 Button Radio Key 100 663 R15 Radio PIR 100 663PET R15PET Radio PIR Pet Aware 100 664 RK3 3 Button Radio Key 100 691 R12 Radio PIR inc Bracket 100 683 RK1B 1 Button Radio Key Pendant 100 662 RR1 Radio Reed Switch 100 056 RDB Radio Doorbell 100 527 RR2
29. y 21 PROGRBAMMING i npe tet etna 22 Programming Options 8 6 23 Radio Doorbell 2 2 24 Doorbell volume aei aa ente inen 24 Doorbell t rie o eere e 25 Radio Key programming ee 26 27 Keypad Code programming eene 28 Entry Delay programming eem 29 Exit Delay programming eeeenm e 29 Specifications ete ppt ed 30 Installation Recorded 31 INTRODUCTION The Ness R16 is a unique fully self contained radio control panel The panel has a built in keypad for programming and user operation a built in piezo siren built in LCD display built in radio receiver built in battery backup and built in dialler The R16 supports up to 16 Ness Radio PIRs and up to 14 Ness Radio Keys All Ness supervised and encrypted radio devices are supported There is even a Doorbell feature with selectable tunes when used with the Ness Radio Doorbell transmitter If the radio doorbell is available in the local frequency In addition to radio devices the R16 has 1 hardwired zone and 1 hardwired tamper input for connection of a wired detection device and external siren cover tamper switch RADIO DOOR SWITCHES RADIO DETECTION The built in piezo siren provides high

Download Pdf Manuals

image

Related Search

Related Contents

User-s-Manual-30032A - Weschler Instruments  TOP_manual_fix_2011  取扱説明書(Ver1.2追加機能分)  Télécharger la Newsletter 2  dServe DSRV-7015C 4GB Grey  emulatore di terminale VT420  Trailer Roll Stability (TRS) Installation Manual [L30040]  ALPHA 700 - Clay Paky  感知フラッシュバルブ制御盤(TEC5)施エ説明害  Tripp Lite APSINT612 User's Manual  

Copyright © All rights reserved.