Contents

1. 1 1 Compressor Danfoss SC21G CPR6021 1 2 Electrics Kit complete ELZ4818 1 2a Start Capacitor part of ELZ4818 1 2b Run Capacitor part of ELZ4818 1 2c Relay part of ELZ4818 1 3 Discharge Line V8020 255 99 1 4 Condenser Coil CLS4800 1 5 Drie DRY 6110 1 6 Suction Line with Capillary V8020 377 1 7 Evaporator Coil CLS4801 1 8 Accumulator K 0336983 1 9 Mains Supply Flex V5000 397 99 1 10 Thermostat ELO7702 1 11 Motor Assembly V5000 404 2 12 Fan Blade FAN 4100 2 13 Motor Mount V5000 235 2 14 Discharge Line Clamp V5000 254 1 15 Condensing Unit Base V8150 210 51 1 16 Condensing Unit Base Foot PLM 6108 2 17 Evaporator Box Foamed V5000 376 1 18 Retaining Bracket V5000 226 99 1 19 Evaporator Box Lid Foamed V8150 225 1 20 Seal Strip 21m per unit RUE3991 1 SKOPE SK1300 WIRING DIAGRAMS 4 ft CENTRE PILLAR LIGHT SKOPE SK1300 WIRING DIAGRAMS 4 ft CENTRE PILLAR LIGHT Mains Flex Sign Box Assembly 30W att Fluorescent Tube 30W att Ballast Starter 2 5Amp Fuse 2 SK OPE Cyclone Refrigeration Unit Compressor Compressor Electrics Box 10 Relay 11 Run Capacitor 12 Start Capacitor 13 Compressor Terminal Block 14 Control Box 15 Thermostat 16 Control Box Terminal Block 17 Evaporator Fan M otor 18 Condenser Fan Motor 19 Socket Box 20 Ensto Connector 2 21 Control Panel 22
2. SKOPE SK1300 PARTS IDENTIFICATION lt gt CABINET ASSEMBLY 2 inch wall Model SK1300 2 1 Cabinet with Ducts amp Shelf Support Strips V1200 291 1 2 Sign Unit Assembly M k 4 C1200 C19 1 3 Sign Back C1200 181 1 4 Sign Sides V5000 182 2 5 SKOPE Cyclone Refrigeration U nit V8020 375 1 Top Hinge Assembly T ype SB R H V5301 388 99 1 Top Hinge Assembly T ype SB V5301 389 99 1 7 Control Panel C1200 789 1 8 4 ft Pillar Light Assembly C1200 670 32 1 9 Shelf V1200 162 99 10 10 Shelf Support Strip V5000 150 6 11 Shelf Bracket V973 99 30 12 R H Door Assembly Type SB M k 3 V6000 D 01R 1 13 L H Door Assembly Type SB M k 3 V6000 D 01L 1 Bottom H inge Bracket T ype SB R H V5000 393 49 1 Bottom H inge Bracket Type SB R H V5000 394 49 1 15 Swivel Castors 95mm high SX X 4339 4 For alternative refrigeration unit options available see pp SKOPE SK1300 IDENTIFICATION PARTS CABINET ASSEMBLY Mk 1 Side Light SL Model SK1300SL SKOPE SK1300 PARTS IDENTIFICATION lt gt CABINET ASSEMBLY Mk 1 Side Light SL Model SK1300SL 1 Cabinet with Ducts amp Shelf Support Strips V1200 291 1 2 Sign Unit Assembly M k 4 C1200 C19 1 3 Sign Back C1200 181 1 4 Sign Sides V5000 182 2 5 SKOPE Cyclone Refrigeratio
3. Thisis pre set to givean internal air temper ature of 2 C to 4 C and in normal circum stances should not be adjusted Thermostat Setting Saginomiya To make colder turn clockwise To make warmer turn anti clockwise D anfoss K P69 To make colder turn differ ential adjustment anti clockwise To make warmer turn clockwise Thermostat Replacement Undo four screws from evaporator box lid Remove lid by lifting vertically Withdraw the capillary from evaporator noting position and length in coil Remove cover from control box or undo thermostat bracket and remove thermo stat When refitting ensure the capillary is fitted in the original position SKOPE Cyclone Unit Removal Removethe sign as described above and disconnect internal light flex plug Undo bolt or screw at right hand of evaporator box then lift the complete unit to the right Turn theunit until thelifting handles are facing the front Theunit may now be removed form the cabinet CAUTION Avoid damage to the underside sealing strip by not dragging the module If damage to the seal occurs it must be re paired prior to reinstallation NOTE Steps or platform about 1 metre high is suggested T his will allow the unit to be lifted carried and put down at about waist height W eight of unit 48K g 10615 SKOPE SK1300 Recommended Service Procedures SK OPE recommend the SK OPE Cyclone demountability and e
4. Passivated Evaporator Coil CLS4801P 99 1 Rotorua SK OPE Cyclone Refrigeration U nit V8020R 102EZ 1 Front Locking Castor SX X 4539 2 12 Adjustable Castor SXX 6181 6 Adjustable Front Locking Castor SX X 6182 2 13 Castor Plate SX X 6180 6 14 Adjustable Foot V5000 314 6 Adjustable Castor K ick Panel K it C1200 127 1 Adjustable Foot K ick Panel K it C1200 128 1 Castor Plate is required for mounting of Adjustable Foot and Adjustable Castors SKOPE SK1300 OPTIONAL PARTS lt gt SOLID DOOR ASSEMBLY x U o a gt 2 2 k 18 Mk 2 Full Length Handle d A Mk 3 Plastic Handle SKOPE SK1300 OPTIONAL PARTS SOLID DOOR ASSEM BLY Mk 1 6 Mk 2 Full Length Handle 1 Magnetic Door Gasket GKT4775 1 2 Torsion Bar Set items 2 3 amp 4 REF4273 1 3 Bush PLM 3289 2 4 Capstan REF1446 1 5 Captive Plate REF1447 1 6 Solid Door Foamed V6502D 1 7 Capstan Pin REF 1448 1 8 Solid Door Top Stay V 7000 45 1 Mk 3 Plastic Handle Solid Door Assembly R H V6500 D 40 32 1 Solid Door Assembly L H V6500 D 41 32 1 nd EEEE gasket retainers 2 Magnetic Door Gasket GKT7883 1 Plastic H andle PLM 7823 1 4 HingeM echanism includes spring amp fastenings HIN5780 1 5 Mount Bush C1300 D 56 1 SKOPE SK1300 OPTIONAL P
5. Terminal Block 3 23 Centre Pillar 24 40W att Fluorescent Tube 25 40W att Ballast OOO Y O UB WIN HM SKOPE SK1300 WIRING DIAGRAMS 5 ft CENTRE PILLAR LIGHT CIEBI LLP To NOTTE BER SL y e ho n SKOPE SK1300 WIRING DIAGRAMS 5 ft CENTRE PILLAR LIGHT Mains Flex Sign Box Assembly 36W att Fluorescent Tube 40W att Ballast Starter 3 0Amp Fuse 2 SK OPE Cyclone Refrigeration Unit Compressor Compressor Electrics Box 10 Relay 11 Run Capacitor 12 Start Capacitor 13 Compressor Terminal Block 14 Control Box 15 R F I Suppression Capacitor when fitted 16 Thermostat 17 Control Box Terminal Block 18 Evaporator Fan M otor 19 Condenser Fan Motor 20 Socket Box 21 Ensto Connector 2 22 Control Panel 23 Connector Block 3 24 CentrePillar 25 58W att Fluorescent Tube 26 60W att Ballast 27 Side Light Assembly optional GOIN Oo UB WN P SKOPE SK1300 OPTIONAL PARTS CABINET Plain Fascia Panel This panel is designed to replace the illumi nated sign for situations where merchandis ing isnot the primary function of the cooler It simply clips into the same position as the il
6. correct replace if necessary Compressor motor has a winding open or shorted Check resistance values Replace compressor if necessary Internal mechanical troublein compressor Improperly wired Replace compressor Check wiring against diagram Low voltage to unit D etermine reason and correct Relay failing to open dueto welded contacts or relay incorrectly mounted D etermine reason and correct replace if necessary Run capacitor defective on CSR motor D etermine reason and replace Excessively high discharge pressure Clean condenser Check power input watts Possibleovercharge insufficient condenser cooling or non condenible gasses Compressor motor has winding open or shorted Check continuity and resistance Replace compressor if faulty Internal mechanical troublein compressor tight May be lubrication Replace compressor TROUBLE SHOOTING 4 Compressor starts and runs but short cycles on overload protector relay may chatter on RSIR CSIR and CSR motors 5 Unit runs OK but short cycles 6 Unit operates long or continuously U nsatisfactory cabinet temperature lt gt Additional current passing through overload protector Check wiring diagram Check for added fan motors etc connected to wrong side of protector Low voltage to unit D etermine reason and correct Overload protector de
7. hole 3 Remove existing capstan and bush from old torsion bar 4 Thread the capstan complete with the bush over the round hook end of the new torsion bar see figure 8 SKOPE SK1300 5 Ensurethe aluminium tube moves freely up and down the torsion bar 6 Fit the new torsion bar into the door frame Ensurethe open end of the flat hook points upwards and manoeuvre the torsion bar through the bottom hinge hole W hen the torsion bar is correctly installed the capstan should not turn 7 Hammer bottom of capstan into hinge hole until the bush is flush with frame 8 Refit door to cabinet 9 Adjust door tension see D oor Tension Adjustment this page Aluminium Tube Torsion Bar Round H ook end Bush Capstan Split Pin holes Door Torsion Bar Figure 8 PRESSURE TEMPERATURE CHART 38 2 39 37 54 36 4 38 44 6 3 34 6 37 50 73 32 8 36 57 8 3 31 0 35 64 9 3 29 2 34 71 10 27 4 33 79 11 25 6 232 86 13 23 8 31 94 14 22 0 30 103 15 20 0 29 111 16 184 28 120 17 16 6 27 129 19 14 8 26 138 20 13 0 25 148 21 11 2 24 158 23 94 23 168 24 7 6 22 179 26 5 8 21 189 27 4 0 20 200 29 2 2 19 212 31 0 4 18 224 32 1 4 17 236 34 3 2 16 248 36 5 0 15 261 38 6 8 14
8. the securing screws and slide the panel forward to disengage the keyhole If a back panel is fitted this must be undipped and removed first SKOPE CYCLONE UNIT The SKOPE Cyclone unit is a self con tained refrigeration module which aligns with port holes on top of the cabinet Re frigerated air is directed through louvers down the front of the cabinet and returns up a full width rear duct NOTE Identification of the correct Cy done amp unit model is essential before com mencing servicing Refer to chapter 5 of this manual for further details of each model Condenser fan motor evaporator fan motor and thermostat may be serviced with Cy done unit in place To provide easier access the sign sides and back may be removed and the Cyclone unit may beunbolted and shifted or renoved completely see Sign Removal Condenser Fan Motor Replacement Remove cover from control box and withdraw motor flex Undo two top screws from mounting bracket and remove complete assembly Evaporator Fan Motor Replacement Undo four screws from evaporator box lid Remove lid by lifting vertically Remove cover from control box and withdraw motor flex Carefully withdraw flex through evaporator wall Undo two top screws from mounting SKOPE SK1300 SERVICE INSTRUCTIONS bracket and renove complete assembly Reseal the flex hole in the evaporator box carefully on replacement Thermostat
9. unit and sign assembly already assembled commence installation at Positioning of M achine Remove protective block from base of SK OPE Cyclone unit before assembly Lift the SKOPE Cyclone unit onto the cabinet top Steps or a platform about 1 metre high are suggested N ote Cyclone Unit weight 48 Kg Check seal against cabinet top ensure there are N O gaps Take care to avoid damaging sealing strip on base Revolve unit so compressor is at L H end Engage left hand slot fully into clip Screw down right hand end Fit side panels onto cabinet engage key hole over screws slide to rear and tighten Screws Clip rear panel into place Connect internal light and sign plugs into power supply sockets located in front of SK OPE Cyclone unit Clip sign into place Fasten sign securing screws to top of each sign panel Proceed with installation as detailed in As sembly amp Installation Instructions booklet attached to door of cabinet Mains Flex Compressor Clip Sign Securing Screw FRONT Power Supply Sockets POSITIONING OF MACHINE The mains flex exits below the rear panel be hind the SK OPE Cyclone unit The flex should be retrieved before the machine is po sitioned when walls and partitions may make access difficult W hen positioning the machine a gap must be left between thetop of the sign panels and ceiling of at least 200mm Adequate ventilation must be p
10. 0 670 SKOPE SK1300 PARTS IDENTIFICATION 4 ft PILLAR LIGHT ASSEM BLY Part Number C1200 670 Pillar Light Assembly 4ft C1200 670 1 1 Sign Box End R H V5000 C21 1 2 Sign Box End L H V5000 C22 1 3 Sign Reflector C1200 C23 1 4 Sign Top Bottom Panel C1200 C24 2 5 Sign Wiring Cover C1200 C26 1 6 Sign Panel Opal PLY 8242 1 7 36 Watt Fluorescent Tube C55 10 6000K ELL5063 1 8 40 Watt Ballast ELZ1251 1 9 Starter ELZ2840 1 10 Fused Connector Block ELZ6461 1 Fuse H older ELZ6462 1 3 0 Amp Ceramic Fuse ELZ6467 2 12 Lampholder ELZ6270 1 13 Lampholder Starter H older ELZ6271 1 Ensto Sign Supply Flex C1250 934 1 Ensto Plug ELZ6458 1 SKOPE SK1300 PARTS IDENTIFICATION 5 ft PILLAR LIGHT ASSEM BLY Part Number V1200 L40 SKOPE SK1300 PARTS IDENTIFICATION 5 ft PILLAR LIGHT ASSEM BLY Part Number V1200 L40 Pillar Light Assembly 5ft V1200 L40 1 1 Centre Pillar V1200 L61 32 1 2 Shelf Support Strip ALX V 5000 150 2 3 Centre Pillar Diffuse PLY 81053 2 4 Centre Pillar Cover PLE4471BK 1560 1 5 Centre Pillar Lamp Channel V1200 L60 32 1 6 Lamp H older ELZ6270 1 7 Lamp Holder Starter H older ELZ6271 1 8 58 Watt Fluorescent Tube L58W 21 4000K ELL6267 1 9 Starter ELZ2840 1 10 65 Watt Ballast fitted behind control panel ELZ8103 1 11
11. 01R 1 13 L H Door Assembly Type SB M k 3 V6000 D01L 1 T Bottom H inge Bracket Type SB R H V5000 393 49 1 Bottom H inge Bracket Type SB R H 5000 394 49 1 15 Swivel Castors 95mm high SX X 4339 4 For alternative refrigeration unit options available see pp SKOPE SK1300 PARTS IDENTIFICATION FLAT SIGN UNIT ASSEMBLY Mk 3 Part Number C1200 680 SKOPE SK1300 PARTS IDENTIFICATION FLAT SIGN UNIT ASSEMBLY Mk 3 Part Number C1200 680 Sign Unit Assembly C1200 680 1 1 Sign W rapper C1200 681 1 2 Sign Top C1200 682 I 3 Sign Reflector C1200 683 1 4 Sign Wiring Cover C1200 684 1 5 Sign Pand 6000 189 2 6 36 Watt Fluorescent Tube 55 10 6000K ELL5063 1 7 40 Watt Ballast ELZ1251 1 8 Starter ELZ2840 1 9 Fused Connector Block ELZ6461 1 T Fuse H older ELZ6462 1 3 0 Amp Ceramic Fuse ELZ6467 2 11 Lampholder ELZ6270 1 12 Lampholder Starter H older ELZ6271 1 Ensto Sign Supply Flex V5000 934 1 Ensto Plug ELZ6458 1 14 Sign Pane Joining Strip C1300 686 I SKOPE SK1300 PARTS IDENTIFICATION FLAT SIGN UNIT ASSEMBLY Mk 4 Part Number C1200 C19 SKOPE SK1300 PARTS IDENTIFICATION FLAT SIGN UNIT ASSEMBLY Mk 4 Part Number C1200 C19 Flat Sign Unit Assembly C1200 C19 1 1 Sign Box End R H V5000 C21 1 2
12. 2 Side Light Diffuser V5060 E71 1 3 58 Watt 5ft Fluorescent Tube L58W 21 4000K ELL6267 1 4 Starter ELZ2840 1 5 Lamp Holder ELZ6270 1 6 Lamp H older Starter H older ELZ6271 1 SKOPE SK1300 PARTS IDENTIFICATION GLASS DOOR ASSEM BLY Part Numbers V6000 741 or V6000 D02 SKOPE SK1300 PARTS IDENTIFICATION GLASS DOOR ASSEM BLY Model Mk 2 Square door profile 1 Glass with Frame V6000 741 1 2 Gasket GKT4775 1 3 Thermal Break long V5000 765 2 4 Thermal Break short V 6000 766 2 Torsion Bar REF5014 1 Torsion Bar Set items 3 4 amp 5 REF4295 1 Bush PLM5075 2 Capstan TUR5100 1 Cotter Pin FAS5076 1 Model Mk 3 Radiused door profile 1 Glass with Frame V 6000 D 02 1 2 Gasket GKT4775 1 3 Thermal Break long V5000 765 2 4 Thermal Break short V6000 766 2 Torsion Bar REF5014 1 Torsion Bar Set items 3 4 amp 5 REF4295 1 Bush PLM5075 2 Capstan TUR5100 1 Cotter Pin FAS5076 1 SKOPE SK1300 PARTS IDENTIFICATION lt gt SKOPE CYCLONE REFRIGERATION UNIT Model SK1500 C Part Number V8020 375 ARA et _ i UD 5 3 11 12 21 8 SKOPE SK1300 PARTS IDENTIFICATION SKOPE CYCLONE REFRIGERATION UNIT Model SK1500 C Part Number V8020 375 ter s lt gt SK OPE Cyclone Refrigeration U nit Assembly V8020 375
13. 274 40 8 6 13 288 42 10 4 12 302 44 122 11 316 46 14 0 10 331 48 15 8 9 346 50 17 6 8 361 52 19 4 7 377 55 21 2 6 393 57 23 0 5 410 59 24 8 4 427 62 26 6 3 445 65 28 4 2 463 67 30 2 4 481 70 32 0 0 500 73 33 8 1 519 75 35 6 2 539 78 37 4 3 559 81 39 2 4 580 84 41 0 5 601 87 42 8 6 623 90 44 6 7 645 94 46 8 8 668 97 48 2 9 691 100 50 0 10 715 104 53 6 12 776 113 57 2 14 828 120 60 8 16 881 128 64 4 18 938 136 68 0 20 996 145 77 0 25 1154 167 86 0 30 1327 193 95 0 35 1518 220 104 0 40 1728 251 113 0 45 1957 284 SKOPE SK1300 TROUBLE SHOOTING 1 Compressor will not Start no hum 2 Compressor will not start hums but trips on overload protector 3 Compressor starts but does not switch off starts winding SKOPE SK1300 Fuse removed or blown no power Ranz n Replace fuse Check reason Overload protector tripped Refer to electrical section Thermostat stuck in open position Repair or replace control Thermostat off due to cold location Relocate control W iring improper or loose Improperly wired Check wiring against diagram Check wiring against diagram Low voltage to unit D etermine reason and correct Start capacitor defective on CSIR or CSR motor D etermine reason and replace Run capacitor defecive on PSC motor D etermine reason and replace Relay failing to close D etermine reason and
14. ARTS ADJUSTABLE KICK PANEL SKOPE SK1300 OPTIONAL PARTS ADJUSTABLE KICK PANEL Adjustable Castor Kick Panel Kit Adjustable Castor K ick Panel K it C1200 127 1 1 Fixed Kick Panel C1200 A54 1 2 Adjustable Kick Panel C1200 A56 1 3 Fixed Side Panel V5000 A57 2 4 Adjustable Castor Side Panel V5000 A60 2 5 Side Panel Fixing Bracket V5000 A58 2 N ote Diagram on following page shows Kick Panel for Adjustable Castors Adjustable Foot Kick Panel Kit Adjustable Foot Kick Panel Kit C1200 128 1 1 Fixed Kick Panel C1200 A54 1 2 Adjustable Kick Panel C1200 A55 1 3 Fixed Side Panel V5000 A57 2 4 Adjustable Foot Side Panel V5000 A59 2 5 Side Panel Fixing Bracket V5000 A58 2 SKOPE SK1300 SPARES CABINET ASSEM BLY CABINET lt gt Control Panel Assembly Y 1100 797 Top Hinge Blank R H V5301 390A Top Hinge Assembly L H n a Top Hinge Assembly L H V5301 389 Top Hinge Blanking Bracket n a D oor Adjuster A ssembly A1100 A 42 49 1 Door Bottom H inge Shim V5000 115B Bottom H inge R H A1100 393 49 Bottom H inge L H A1100 394 49 W ire Shelf Y 1100 162 Adjustable Shelf Bracket R H R1101 598L Adjustable Shelf Bracket L H R1101 598R Cabinet W iring Junction Box Assy Y 1100 G 29 1 SK OPE Name Badge NAM 8016 GY SV N eon Switch Encapsulated Label LAB0088 Swivel Castor Mounting P
15. Certain conditions may ne cessitate more regular attendance e g dusty or kitchen environment Servicing and electrical work should be car ried out by an authorised Service Agent Brief instructions are located on the top of the SK OPE Cyclone unit SK OPE recom mend fitting of approved spare parts only refer to chapters 5 6 amp 8 SIGN Internal access may be gained with the sign unit in place To replace a tube ballast starter or fuse M k 4 sign only etc undo the 5 screws securing the sign top cover and re move On the Mk 4 sign the sign top panel can be removed by loosening the 4 fixing screws 1 2 turns and pulling the sign top forward and then lifting up Slide the sign panel up carefully to gain access to the inte rior W hen replacing carefully slide the sign panel down into the retaining lugs taking care not to scratch the panel Refit the top cover with screws and star washers Sign Removal Undo two screws which hold the sign top cover to the side panels Alernatively for Mk 4 sign pivot sign box retainer brackets located on sign sides clear of sign box top The sign can now be lifted vertically and re leased from its retaining clips Unplug the power flex and remove the sign If required the sign may be positioned so that its bottom dips engage with the side panel top clips This will allow a working space of about 250mm 10 for unplugging power connectors Side Panels To remove loosen
16. E SK1300 SERVICE INSTRUCTIONS Gasket Replacement The door gaskets simply clip into the door gasket retainer and may be removed for re pair or replacement simply by peeling away from gasket retainer starting at the corners N ew gaskets when fitted may be lightly lubricated with a clear silicone grease or similar compound This will lessen the possibility of the gasket rolling Should the gasket be out of shape when in place use hot air i e from hair drier to realign Door Tension Adjustment IMPORTANT Doors should only be ten sioned enough that they self close with the door gasket forming an air tight seal O ver tensioning could result in deformation of the internal torsion bar 1 Turn capstan with steel rod 03mm to remove tension on the split pin 2 Using another steel rod turn the capstan in the direction that the door closes to increase the tension 3 Replace split pin when the required tension adjustment has been made In the event the door tension can no longer be adjusted the torsion bar may need replac ing see Torsion Bar Replacement below Torsion Bar Replacement 1 Remove door from cabinet see Door Removal p 14 Lay door down on a flat surface 2 Remove old torsion bar by carefully levering out the bottom bush from the door frame Pull old torsion bar out from door frame The end of the torsion bar will need manoeuvred to allow the flat hook end to dear the hinge
17. ELL5065 3 Amp Ceramic Fuse ELZ6467 Fused Connector Block ELZ6461 Fuse H older ELZ6462N C SHELVING Shelf Frame Y 1101 162 1 Shelf D ivider Spares available on request Acrylic Front Spares available on request Speedfeed M atts Spares available on request SKOPE SK1300 REFRIGERATION UNIT COOLER UNIT Refrigeration U nit Assembly Y C1120R 128Z2 Unit J unction Box Assembly Y C1100 R86 Control Box Assembly Y C1100 E50X 2 Condenser M otor Assembly Y C1100 501 Suction Line Assembly Y C1100 378 Compressor DAN FOSS SC15G CPR7344P Evaporator Coil CLS8839 Condenser Coil CLS8841 Start Capacitor ELC2369NC Relay ELR2367NC H igh Pressure Switch ELS8505 Unit H andle HAN 0000 Drier Production D RY 8783 Drier Service DRY 6110 Condenser Fan Blade FAN 4100 Evaporator Fan Assembly Y C2100 484Z Condenser Fan M otor Y C1100 404B Evaporator Fan Capacitor Y C2100 X 27 R F I Suppression Capacitor B3100 E65 U nit W iring Diagram Label Type 1 Controller LAB0054 U nit W iring Diagram Label Type 2 Controller LAB0056 SKOPE SK1300
18. Fused Connector Block ELZ6461 1 Fuse older ELZ6462 1 3 0 Amp Ceramic Fuse ELZ6467 1 13 Centre Pillar Strip V5000 82 1 SKOPE SK1300 PARTS IDENTIFICATION SOLID CENTRE PILLAR ASSEM BLY Part Number C1200 L43 SKOPE SK1300 PARTS IDENTIFICATION SOLID CENTRE PILLAR ASSEM BLY Part Number C1200 L43 Solid Centre Pillar Assembly C1200 L43 32 1 Solid Centre Pillar V1200 L64 32 1 Shelf Support Strip ALX V5000 150 2 Pillar Cover and Element Assembly V5060 L44 1 Centre Pillar Cover PLE4471BK 1560 1 8 Centre Pillar Element ELE2611 1 M etal Strip sides V 5000 82 2 M etal Strip centre V 7000 82 1 Rubber Inseal 1560 x 60mm RU E5120 1 4 Fused Connector Block ELZ6461 1 2 Fuse H older ELZ6462 1 3 0 Amp Ceramic Fuse ELZ6467 1 SKOPE SK1300 PARTS IDENTIFICATION SIDE LIGHT ASSEMBLY SL Part Number V1200 L95 o A SKOPE SK1300 PARTS IDENTIFICATION SIDE LIGHT ASSEMBLY SL Part Number V1200 L95 PARTS IDENTIFICATION EXTRUDED SIDE LIGHT ASSEMBLY XL Part Number V5060 670 SKOPE SK1300 PARTS IDENTIFICATION EXTRUDED SIDE LIGHT ASSEMBLY XL Part Number V5060 670 Extruded Side Light Assembly L H V5060 670L 32 1 Extruded Side Light Assembly R H V5060 670R 32 1 Side Light Channel L H V5060 671L 32 1 Side Light Channel R H V5060 671R 32 1
19. SKOPE REFRIGERATION SOLUTIONS SKOPE SK1300 2 DOOR Top Mounted Vertical Cooler Operating and Service Manual December 2001 Edition MAN7976 u CONTACT ADDRESSES Designed amp Manufactured by SKOPE SKOPE INDUSTRIES LIMITED NEW ZEALAND HEAD OFFICE PO Box 1091 Christchurch N ew Zealand Freephone 0800 947 5673 Fax 03 348 2458 E mail enquiry skope co nz AUCKLAND PO Box 12 996 Penrose Auckland Freephone 0800 947 5673 Fax 09 525 3994 SKOPE AUSTRALIA PTY LIMITED A C N 000 384 270 PO Box 6493 W etherill Park NSW 2164 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry 9 skope co nz SKOPE MIDDLE EAST PO Box 37 663 D ubai United Arab Emirates Telephone 971 4 339 3907 Fax 971 4 339 3908 E mail howaida skope co nz www skope co nz Copyright O 2001 SK OPE Industries Limited All Rights Reserved D ecember 2001 edition MAN 7976 SKOPE SK OPE is the registered trademark of SK OPE Industries Limited Christchurch N ew Zealand ASI M PPI 5 ISO 9 SK OPE Industries Limited is accredited to the International Quality Assurance System ISO 9002 TABLE OF CONTENTS SPECIFICATIONS Cabinet and Refrigeration Unit 7 INSTALLATION Assembly eet Hed liege ds lush geri REA hee ER hee erat dba 8 Positioning of Machine eddie ad FEE iR U Uc sare ae ee e eS 8 OPERATION Safety I
20. Sign Box End V5000 C22 1 3 Sign Reflector C1200 C23 1 4 Sign Top Bottom Panel C1200 C24 2 5 Sign Wiring Cover C1200 C26 1 6 Sign Panel Opal PLY 8242 1 7 36 Watt Fluorescent Tube C55 10 6000K ELL5063 1 8 40 Watt Ballast ELZ1251 1 9 Starter ELZ2840 1 10 Fused Connector Block ELZ6461 1 3 Fuse H older ELZ6462 1 3 0 Amp Ceramic Fuse ELZ6467 2 12 Lampholder ELZ6270 1 13 Lampholder Starter H older ELZ6271 1 A Ensto Sign Supply Flex C1250 934 1 Ensto Plug ELZ6458 1 SKOPE SK1300 PARTS IDENTIFICATION CURVED SIGN UNIT ASSEM BLY Part Number C1200 S21 SKOPE SK1300 PARTS IDENTIFICATION CURVED SIGN UNIT ASSEM BLY Part Number C1200 S21 Curved Sign Unit Assembly C1200 521 1 1 Sign Box End R H V5000 C21 1 2 Sign Box End L H V5000 C22 1 3 Sign Reflector C1200 C23 1 4 Sign Top amp Bottom Panel C1200 C24 2 5 Sign W iring Cover C1200 C26 1 6 Sign Panel Opal PLY 8242 1 7 36 Watt Fluorescent Tube C55 10 6000K ELL5063 1 8 40 Watt Ballast ELZ1251 1 9 Starter ELZ2840 1 10 Fused Connector Block ELZ6461 1 Fuse H older ELZ6462 1 3 0 Amp Ceramic Fuse ELZ6467 2 12 Lampholder ELZ6270 1 13 Lampholder Starter H older ELZ6271 il Ensto Sign Supply Flex C1250 934 1 Ensto Plug ELZ6458 1 SKOPE SK1300 PARTS IDENTIFICATION lt gt 4 ft PILLAR LIGHT ASSEM BLY Part Number C120
21. de Panel with one M 4 screw Drill 2 7mm diameter holes into the cab inet back to secure the Fixing Brackets and Side Panels with self taping screws Loosen the M 4 screw to align the A djust able Panels suitable to the floor level Temperature Indicators The Dial Thermometer is fitted as standard and is located inside the cabinet Part N o V5000 95A There are two kinds of optional temperature indicators SKOPE SK1300 OPTIONAL PARTS CABINET ASSEM BLY SKOPE SK1300 OPTIONAL PARTS lt gt CABINET ASSEM BLY Cabinet with Ducts and Shelf Support Strips V1200 291 1 5 Plain Facia Panel glass doors C1200 373 1 Plain Facia Panel solid doors C1200 295 1 5ft Centre Pillar Light Assembly V1200 L40 1 Switched Centre Pillar Light Assembly C1200 673 1 Switched Centre Pillar 3 Terminal Switch ELS6560 1 Switched Centre Pillar Anti Sweat W ire ELE2611 1 4 Control Panel for SAE Thermometer R1200 789 1 5 Control Panel for Solid Doors C1200 791 1 Solid Door Assembly R H V6500 D 40 I Solid D oor Assembly L H V6500 D41 1 gt Solid Door Top H inge Assembly R H V7301 388N 99 1 Solid Door Top H inge Assembly L H V7301 389N 99 1 Solid Door Bottom H inge R H C1300 D 55R 1 Solid Door Bottom H inge L H C1300 D 55L 1 9 Solid Door Bottom Stay V7000 044 2 10 Deep Shelf for Solid Doors R1200 161 99 5 1
22. ee Standard Parts Identification Compress the centre pillar at the top U ndip and peel off the plastic cover from top to bottom The fluorescent tube may be re moved by revolving it until the pin position allows withdrawal SKOPE SK1300 W hen refitting compress the pillar top and clip the plastic cover on progressively from top to bottom NOTE The plastic cover is fitted with metal strips to attract the magnetic door gasket Centre Pillar 3A Fuse amp FuseH older ur COM PRESS mami M ani Lamp H older iu amp Starter E 4ft Fluorescent above ballast ube Plastic Cover 4ft Centre Pillar Light Figure 3 Centre Pillar 3A Fuse B ona EE accessiblefrom 00 inside cabinet COM PRESS mao an seS LampHolde amp Starter E 5ft Fluorescent Tube Plastic Cover 5ft Centre Pillar Light Figure 4 SERVICE INSTRUCTIONS DOORS Door Torsion Type SB doors have several different style hinge plates but the torsion mechanism re mains the same for each Turn capstan with Silver steel rod or drill shank to remove ten sion on pin Remove pin and turn capstan to achieve desired tension then replace pin see figure 5 below Square D oor Radiused Frame Door Frame Early Style Current Style Figure 5 Door Gasket Replacement The door gas
23. el cas tors 1 Front Locking 95mm high fitted with a foot operated wheel lock 2 Adjustable 115mm to 130mm adjustable and non lock able 3 Adjustable Front Locking 115mm to 130mm adjustable with foot op erated wheel lock A Castor Plate is required for mounting of each adjustable castor See page 8 5 for part numbers Adjustable Feet Adjustable between 32mm to 69mm A Cas tor Plate is also required for mounting of each adjustable foot Adjustable Kick Panel Adjustable K ick panels are supplied in kitset form T he kit consists of front and side pan els which are adjustableto suit varying castor and feet heights There are two types of Adjustable K ick Pan el K its available Adjustable Castor K ick Pane K it This suits when swivel castors are fitted This includes the standard non adjusta ble castor as well as the optional adjusta ble and front locking types Adjustable Foot K ick Pane K it This suits when adjustable feet are fitted To fit Adjustable Kick Panels see page 8 10 Fit the Fixed Kick Panel to the cabinet front base with self taping screws Fit Adjustable K ick Panel to the outside SKOPE SK1300 OPTIONAL PARTS of the Fixed Front Kick Panel with M4 screws position height to suit floor level Fit the Adjustable Side Panels and the Fixed Side Panesl to the Fixed Front K ick Panel with one M 4 screw Fit the Fixing Brackets to the Side Panel and the Adjustable Si
24. f R 134a CABINET Electrical Power supply for cabinet fittings enters at the top right hand side of the cabinet and is directed along the inside of the control panel to the interior light To gain access to the internal connections open the doors fully and remove the control panel fixing screws at each end W hen refit ting ensure star washers are refitted SKOPE SK1300 SERVICE INSTRUCTIONS INTERIOR LIGHTS Side Lights To replace fluorescent tube or starter com press the back section of the diffuser so that it disengages from the side light housing and push back to gain access to light W hen refitting engage back section of the diffuser into housing Compress and snap front section of diffuser into place progres sively down its full length see figure 2 COMPRESS TubeH older Diffuser Figure 2 Centre Pillar Light W hen the standard centre pillar is fitted with 4 ft fluorescent tube figure 3 the tube ballast starter and fuse are located in side the centre pillar and may be replaced without removing shelves or product from the cabinet See Standard Parts dentifica tion section for part numbers If the cabinet has the optional full height centre pillar with 5 ft fluorescent tube fig ure 4 the ballast is fitted on a step in the cabinet top located behind the control panel and the fuse is fitted at the top of the pillar and protrudes into the interior of the cabi net S
25. fective Check current replace protector Run capacitor defective on CSR motor D etermine reason and replace Excessive discharge pressure Clean condenser check ventilation check for restrictions in refrigeration System Suction pressure too high Check for possibility of misapplication Compressor too hot insufficient suction gas cooling Check refrigerant charge fix leak add if necessary Check return vapour temperature and suction superheat Compressor motor has a winding shorted Overload protector Replace compressor See 4 above Thermostat requires adjustment or incorrectly positioned Adjust or relocate thermostat Incorrect refrigerant charge Short of refrigerant O vercharge of refrigerant Thermostat not cooling correctly A djust refrigerant charge Fix leak add charge Remove refrigerant to correct charge A djst thermostat clockwise colder Cooler has excessive load Establish load within limits Evaporator coil iced D efrost evaporator check refrigeration Restriction in refrigeration System D etermine location and clear restriction Flush with dry nitrogen Replace component if blockage will not clear Dirty condenser Clean condenser A dvise dient how to regularly clean condenser SKOPE SK1300 TROUBLE SHOOTING 6 continued Unit operates long or continuously Unsatisfactory cabi
26. itrogen only up to 250 psig if there is no pressure drop over 24 hours the fault should be treated as a capillary restriction 2 Compressor not pumping efficiently W here the frosting effect is not as cold as it should be Symptoms include compressor SERVICE INSTRUCTIONS body hotter than normal condenser cooler than normal and the compressor may make an unusual hissing sound All of these symp toms depend on the severity of the problem Theonly way to provea pumping problem is to perform a compressor pump down test braze closed compressor suction line Open discharge line then run the compressor to pull a vacuum on a vacuum gauge T he com pressor should pull down to approximately 30 inches vacuum then turn the compres sor off and this vacuum must be held with out any lossfor 5 minutes If the Compressor does not pass these tests it is not pumping efficiently and must be replaced T here are different methods to proving pumping efficiency If the test is performed with a system charged with refrigerant a deep vacuum will not be achieved 3 Capillary restriction W ith a totally blocked capillary there will beno refrigeration effect A partially blocked capillary may have similar symptoms to a system being short of refrigerant Flush are stricted capillary with dry nitrogen If the capillary will not clear it must be replaced After the repair the drier must be replaced every time the refrigeration syste
27. kets simply clip into the door frame extrusion and may be removed for re pair or replacement simply by peeling from frame starting at corner N ew gaskets when fitted may be lightly lubricated with a clear silicone grease or similar compound This will lessen the possibility of the gasket roll ing Should the gasket be out of shape when in place use hot air i e from hair drier to realign Door Removal Slacken off door tension and remove pin Re move control panel unbolt top hinge and lift door clear of bottom pivot CAUTION D oors are heavy and for safety reasons there moval procedure should be carried out by two people Door Repair Torepair torsion bar assembly turn door up side down and pull out old torsion bar An gle torsion bar to clear the hook at end Replace parts as required and refit NOTE Glass replacement is not considered economical as the glass is fixed to the frame for integral strength D oor replacement is recommended See page 6 9 for part num bers Glass Door Identification SK OPE glass doors fitted to the SK 1300 have either the M k 2 square door frame profile see figure 6 or the new Mk 3 ra diused door frame profile see figure 7 See diagrams below for the two different door extrusion profiles Mk 2 Square Door Frame Profile Figure 6 Ez JE My N N N NN Mk 3 Radiused Door Frame Profile Figure 7 SKOP
28. late SX X 6180 4 Adjustable Swivel Castor Standard SX X 6181 2 Adjustable Swivel Castor Locking SX X 6182 2 Adjustable Stability Foot Y 1100 314 49 4 W hen ordering spare parts please specify colour white black etc finish anodised or paint ed and sign panel artwork if applicable SKOPE SK1300 SPARES CABINET ASSEM BLY GLASS D OOR lt gt Glass Door Assembly R H Y 2100 740R Glass D oor Assembly L H Y 2100 740L Glass D oor G asket GKT9653 D oor Adjuster A ssembly A1100 A 42 49 Torsion Bar REF0092 Capstan TUR7635 Bush PLM 5075 2 INTERIOR LIGHTS Side Light Assembly R H Y 1100 670R 32 Side Light Assembly L H Y 1100 670L 32 Centre Pillar Light Assembly n a Centre Pillar Channel Assemly R H n a Centre Pillar Channel Assemly L H n a Light Diffuser Y 1100 E71 58 W att Fluorescent T ube 5ft L58W 21 840 4000K Coolwhite ELL6267 L58W 11 860 6000K Daylight ELL9390 Starter ELZ2840 Lamp H older ELZ6270 Starter H older ELZ6271 SKOPE SK1300 SPARES OPTIONAL PARTS LIGHTED SIGN BOX lt gt Sign Assembly packed Y 1100 501 Curved Sign Panel Clear PLY 0118 Curved Sign Panel O pal PLY 0120 58 W att Fluorescent T ube 5ft n a 58 65 W att Ballast n a Starter ELZ2840 20 W att Ballast ELZ1039 18 W att Fluorescent Tube
29. luminated sign The sign replacement pan el is available on new coolers ex factory and may also be retrofitted Side Lights A full height fluorescent tube 5 ft is partial ly recessed into the side of the cabinet to provide increased illumination A clear cylin drical cover is fitted to protect the tube from damage T he ballast is fitted on a step in the cabinet top behind the control panel All lighting and ancillary heating elenents op tional are protected through the fuse fitted in the centre pillar 5 ft Centre Pillar Illumination A full height fluorescent tube 5 ft is fitted inside the centre pillar A fuse holder is fitted at the top of the pillar and protrudes into the interior of the cabinet T he ballast is fitted on a step in the cabinet top behind the control panel Solid Doors For use in non merchandising applications and energy conservation D ue to the thicker construction the sign control panel and hinging systems are also required to be re placed Internal and external finishes of the door must be specified when ordering Switched Centre Pillar Illumination The switched centre pillar has a heater ele ment running the full height of the doors which prevents condensation occuring when the illumination is off The switch is inside the cabinet on the centre pillar Deep Shelves D eep shelves are fitted in conjunction with solid doors Swivel Castors There are three kinds of optional swiv
30. m is opened the drier must be replaced The Cyclone must be fully evacuated and charged to the volume of refrigerant indicat ed on the Cyclone serial plate All service lines must be purged Finally pinch off the gauge process lines or remove line piercing valves and braze the system closed SK OPE recommend against leaving service valves in the system as these are prone to leak and are open to abuse Perform a final system leak test Refrigerant R134a Handling Precautions It it necessary to maintain dedicated H FC service equipment and parts Refrigeration gauges Service lines Fittings Vacuum Pump Charging equipment B Driers Compressors Temperature Pressure chart H FC R134a refrigeration systems require special service procedures because of the highly hygroscopic moisture sensitive poly ester compressor oil The system especially compressor must only be open for the very minimum time to prevent moisture ingression All parts required for servicing must be at hand before the system is opened and there should be no interruption until the System is on the vacuum pump or her metically sealed The system must not be open for longer than 20 minutes max imum The drier must be replaced every time the system is opened Clean work practices are essential SKOPE recommend brazing the system closed after service as valves are prone to leak due to the nature o
31. n U nit V8020 375 i Top Hinge Assembly T ype SB R H V5301 388 99 1 Top Hinge Assembly Type SB L H V5301 389 99 1 7 Control Panel C1200 789 1 8 4ftPillar Light Assembly C1200 670 32 1 9 Shelf V1200 162 99 10 10 Shelf Support Strip V5000 150 6 11 Shelf Bracket V973 99 30 12 R H Door Assembly Type SB M k 3 V6000 D01R 1 13 L H Door Assembly Type SB M k 3 V6000 D01L 1 14 Bottom H inge Bracket T ype SB R H V5000 393 49 i Bottom H inge Bracket T ype SB R H V5000 394 49 1 15 Swivel Castors 95mm high SX X 4339 4 For alternative refrigeration unit options available see pp SKOPE SK1300 PARTS IDENTIFICATION CABINET ASSEMBLY Mk 2 Side Light XL Model SK1300XL SKOPE SK1300 PARTS IDENTIFICATION lt gt CABINET ASSEMBLY Mk 2 Side Light XL Model SK1300XL 1 Cabinet with Ducts amp Shelf Support Strips V1200 291 1 2 Sign Unit Assembly M k 4 C1200 C19 1 3 Sign Back C1200 181 1 4 Sign Sides V5000 182 2 5 SKOPE Cyclone Refrigeration U nit V8020 375 1 Top Hinge Assembly T ype SB R H V5301 388 99 1 Top Hinge Assembly T ype SB L H V5301 389 99 1 7 Control Panel C1200 789 1 8 4ftPillar Light Assembly C1200 670 32 1 9 Shelf V1200 162 99 10 10 Shelf Support Strip V5000 150 6 11 Shelf Bracket V973 99 30 12 R H Door Assembly Type SB M k 3 V6000 D
32. net temperature 7 Start capacitor open shorted or blown 8 Relay defective or burned out 9 Suction line frosted 10 Unit noisy SKOPE SK1300 nadequate air circulation Internal Improve air movement allow airflow around stock External Remove any restrictions to condensing ventilation Compressor not pumping efficiently Replace compressor Filter dirty if applicable Clean or replace Faulty fan motor Relay contacts not opening properly Check rotation Replace if necessary Clean contacts or replace relay if necessary Prolonged operation on start cycle due to a Low voltage to unit a Determine reason and correct b Improper relay b Replace Excessive short cycling D etermine reason for short cycling see 5 above and correct Improper capacitor Incorrect relay D etermine correct size and replace Check and replace Line voltage too high or too low D etermine reason and correct Excessive short cycling D etermine reason for short cycling see 5 above and correct Relay being influenced by loose vibrating mount Evaporator fan not running Remount rigidly D etermine reason and correct O vercharge of refrigerant capillary systems Loose parts or mountings Correct charge Find and tighten Tubing rattle Reform to be free of contact Bent fan blade causing vib
33. nformation uker tk hous Pade F LGET LET E e 9 Operation of 10 LOAN tt v b dy ach E Cte eet ese pa E Pee iG A ga LU Ets EN 11 A bo PO tov Qua e EUR A fp nale 11 MN ag zas Ue esce s eee emake Rt hanes eot E QUAE T uM x e 11 SERVICE INSTRUCTIONS System Service N OLO SE 23 RATON UNE rm 24 ER M DST SETE PE ae Adak Ced xc Pe Y ccs d 24 Interior esc Le pe deg trece ob sede one o up ed a ra etu dla ge dig a Ner ete 26 lighted SIGH BUS ucc eS etse Saker ii 27 CHI ve Ene da pua ew Mara Va d Ut ad SU PI du 27 V oM RENE ERR RT o REA a 28 Pressure Temperature Chart uat pa ST e rete RC ADLER EORR 29 Trouble BS es 30 WIRING DIAGRAMS 4 ft Centre Pillar Light Model 34 5ft Centre Pillar Light M Ode A er be betaine es E C 35 Side Right Model s Ret Mae A eters ahha heute nV 36 OPTIONAL PARTS IDENTIFICATION de C Tru T 36 Refrigeration A Duo e LARGO es edie ne By CES Eu e p XE D Kise 37 STENA SINN se Eu uu Dd eot wc 38 Pillar Light Assembly sarte tr uh e e E o 39 Solid BO ASD sy mirc V E Dit ote ds 40 Adjustable Bottom Kick 41 SPARES Cabinet Assemblage a dde s LE NT 42 Optional Part Smissen eyrar ura pri
34. on Ensure the door gaskets form a good seal with the cabinet LOADING Shelves may be positioned at different heights to suit various products Always en sure that the shelf clips are securely engaged in each of the six shelf support strips Support strips are marked for easy loca tion of shelf clips For even cooling and efficient operation al low air Space around packages etc Do not allow products to overhang the front of the shelf as this could prevent the door from shutting or cause glass breakage Leave an airspace of at least 75mm 3 above pack ages etc on the top shelf CLEANING W hen necessary wash both interior and ex terior of cabinet with soapy water Exterior of cabinet may be waxed with automobile polish for extra protection THE MACHINE MUST BE DISCON NECTED FROM THE MAINS SUPPLY BEFORE CLEANING THE CONDENS ER SERVICE INSTRUCTIONS Condenser coil must be kept clean for effi cient and reliable operation Clean with a brush and vacuum cleaner regularly Access to the condenser is gained by removal of the sign panel Undo two screws which hold the top of the sign to the side panels The sign panel can then be lifted vertically unplugged and re moved Alternatively the bottom clips in the sign may be engaged on the top clips of the side panels to provide a space for clean ing The preventative maintenance recommen dation is to clean the condenser at 1 to 6 month intervals
35. ration Replace blade Fan motor bearings worn Replace motor PARTS IDENTIFICATION lt gt CABINET ASSEMBLY 3 inch wall Model SK1300 SKOPE SK1300 PARTS IDENTIFICATION lt gt CABINET ASSEMBLY 3 inch wall Model SK1300 1 Cabinet with Ducts amp Shelf Support Strips C1200 291 1 2 Sign Unit Assembly M k 3 C1200 680 1 Sign Back C1200 181 1 4 Sign Sides V5000 182 2 5 SKOPE Cyclone Refrigeration Unit V8020 375 1 2 Top H inge Assembly T ype SB R H C1200 388 99 1 Top Hinge Assembly T ype SB L H C1200 389 99 1 Control Panel C1200 789 1 4 ft Pillar Light Assembly C1200 670 32 1 5 Shelf C1200 162 99 10 Shelf Ticket Strip PLE6615 0590 10 10 Shelf Support Strip V5000 150 6 11 Shelf Bracket V973 99 30 R H Door Assembly Type SB Mk 2 t V6000 740R 1 R H Door Assembly SB Mk 3 t V6000 D 01R 1 18 L H Door Assembly Type SB M k 2 t V6000 740L 1 L H Door Assembly Type SB M k 3 t V6000 D 01L 1 35 Bottom H inge Bracket T ype SB R H V5000 393 49 1 Bottom H inge Bracket Type SB R H V5000 394 49 1 15 Swivel Castors 95mm high SX X 4339 4 For alternative refrigeration unit options available see pp T For door identification see pp SKOPE SK1300 PARTS IDENTIFICATION lt gt CABINET ASSEMBLY 2 inch wall Model SK1300 2
36. rovided above the SK OPE Cyclone unit for effi cient operation Maximum recommended ambient temperature 32 C Avoid direct sunlight warm draughts etc W hen siting the machine adequate allow ance should be made for door opening The doors have internal torsion bars which are pretensioned at the factory The machine must be positioned on a level surface for the doors to shut and seal correctly and to pre vent the condensate tray from overflowing Remove all packaging material from the shelves fit shelf support brackets at the de sired heights and relocate shelves Rear Panel REAR Side Panel Fixing Screw SK OPE Cyclone Refrigeration U nit Sign Unit or Plain Facia Panel Cabinet Top View Figure 1 SKOPE SK1300 OPERATION SAFETY INFORMATION W hen using any electrical appliance basic safety precautions should always be ob served READ THESE INSTRUCTIONS CAREFULLY Do not use this appliance for other than its intended use DO OVERLOAD POWER SUPPLY Machine rated at 5 6 Amp 240 Volt Use this appliance only on the voltage specified on the rating plate or in these instructions Ensure ventilation of SKOPE Cyclone refrigeration unit Condenser coil must be kept clean To ensure trouble free performance it is rec ommended that on a regular basis the unit be isolated from the power supply and a vacuum cleaner used to remove dust and fluff from the condenser Be ver
37. t re RPO ae 44 Refrigeration tudo win ada dander rtr o E ea nitet bok s le 45 SPECIFICATIONS CABINET CONSTRUCTION Exterior Interior finish W hite powdercoat on galvanised steel 50mm thick polyurethane foam Cyclo isopentane blowing agent 10 CsH Insulation DIMENSIONS H eight standard castors 2195mm H eight adjustable castors 2215 to 2230mm W idth 1480mm D epth 700mm Floor area 1 04m Internal volume 1310 litres 230 240 Volts a c 50 Hz single phase supply Rated current 5 6 Amps LIGHTING Vertical interior side light 2 x 58 Watt fluorescent tubes Centre pillar light 1 x 58 W att fluorescent tubes ILLUMINATED SIGN 370mm high sign box with 1 5mm thick polycarbonate curved sign panel Sign light 1 x 30 W att fluorescent tube DOORS Self closing aluminium framed double glazed with toughened safety glass SHELVING W hite plastic coated adjustable steel wire shelves REFRIGERATION SYSTEM Integral top mounted SK OPE Cyclone refrigeration unit Induced draught condenser and evaporator coils N ominal capacity 820 W atts Compressor D anfoss SC21G Refrigerant R134a Charge 720 grams SK OPE Industries Limited reserve the right to alter specifications without notice SKOPE SK1300 INSTALLATION ASSEMBLY INSTRUCTIONS If the SK OPE SK 1300 cabinet has been sup plied with the SKOPE Cyclone
38. xchangeability philoso phy which in essence means T he customer must not be inconvenienced during system maintenance In the unlikely event of Refrig eration failure an exchange unit is simply swapped in a matter of minutes There is no cabinet down time or unloading product In one 5 minute visit the customer s inconven ience ends The faulty Cyclone is then re moved to the workshop for repair as time allows For a suspected refrigerant problem discon nect the evaporator fan motor and with the system running a frost line will become ob vious after approximately 5 minutes Entire evaporator accumulator and suction line right up to compressor must be frosting Compressor at suction inlet will sweat If these conditions are not met the system is faulty either a short of refrigerant or b compressor not pumping efficiently or c capillary restriction T he system must then be opened see Refrig erant H andling R134a Precautions section and gauges temporarily fitted i e either temporarily fit line piercing valves or braze in service lines 1 Short of refrigerant W here the frosting effect is shorter than re quired unless all refrigerant is lost where there is no frosting effect Only a small amount of refrigerant will exit the system A leak test refrigerant dry nitrogen mix up to 250 psig should be performed to lo cate the leak If no leak is found a pressure test should be performed dry n
39. y careful not to touch moving parts Do not cover the grilles or block the entry or exhaust of airflow by placing any object or material up against or on top of theunit Donot probe any opening e Remove Cyclone unit for transporta tion The refrigerator is not designed to be stable in motion Disconnect machine mains power sup ply before attempting to perform any electrical service or maintenance f the power supply cord of the machine is damaged the cord must be replaced by a cord with part number as specified for the relevant refrigeration unit in Standard Parts Identification section of this manual Regulations require that all electrical work be carried out only by authorised persons For your own safety and that of others ensure this is done SKOPE SK1300 OPERATION OF MACHINE Plug in machine and check operation of SK OPE Cyclone unit and lights Com pressor evaporator and condenser fans should all operate initially This may be ver ified by listening for compressor switch on checking air movement around the top left hand side of the cabinet and out of the lou vered outlet inside the cabinet or out of the bottom of the rear duct Compressor and Condenser fan should switch off when cabi net internal temperature reaches 2 C to 4 C The internal cabinet air will continue to cir culate at all times The lights which illumi nate the top sign and cabinet interior are permanently