Home

QUICK USER GUIDE

image

Contents

1. To perform many of the CA 6 control panel functions you must enter a code By default the following codes are preprogrammed in the control panel master administrator code for partition 1 1234 service code 12345 SATEL CA 6 3 The master user administrator can add new users For security reasons each user should have their individual code The master user defines an authority level for each user The functions to which the user has access depend on the authority level For description of the authority levels please refer to the full user manual The master user can create up to 12 users The users can have access to one or both partitions The service code enables access to the service functions but does not allow everyday operation of the control panel using this code you will not be able to arm or disarm the system 3 Arming Prior to arming make sure that there are no violated zones e g open windows or doors which may prevent the system from arming if the system has been so configured by the installer After arming the exit delay countdown may be running which allows you to leave the premises without triggering alarm the zones will be armed only when the exit delay countdown is finished If during the exit delay countdown the control panel will not register leaving the premises the zone monitoring the exit route will not be violated the selected zones can be automatically bypassed thus enabling you to stay
2. T an b O O p amp lt CA 6 Firmware version 5 06 ca6_us_en06 12 QUICK USER GUIDE The full version of User Manual and other manuals are available on CD included in the control panel delivery set or on the website www satel eu CE SATEL sp Zz 0 0 ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www satel eu We are glad that you have chosen a product offered by us We wish you satisfaction with your choice and would like to assure you that we are always ready to provide expert assistance and information on our products Out of concern for the environment SATEL has decided to reduce its paper consumption Instead of comprehensive manuals we offer you a short guide for control panel users It contains all the information necessary for daily operation of the panel The other manuals are available in electronic form at www satel eu SATEL is a manufacturer of a wide range of dedicated devices for use in security systems Additional information on these products can be found on the website www satel eu or at points of sale offering our products Hereby SATEL sp z 0 0 declares that this control panel is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at www satel eu ce Read this manual carefully before operating your security system Changes modifications or
3. conds auxiliary alarm press and hold down the 0 key for approx 3 seconds panic alarm press and hold down the key for approx 3 seconds 6 Viewing alarm log Press and hold down the 5 key for approx 3 seconds Information on the alarm is presented on the numbered LEDs asingle LED is illuminated alarm from the zone whose number corresponds to that of the LED a single LED is blinking tamper alarm from the zone whose number corresponds to that of the LED double EOL zone wiring seven out of the eight LEDs designated by numbers 1 8 are illuminated and one of the LEDs designated by numbers 1 5 is blinking alarm from keypad Blinking of the LED has the following meaning 1 fire alarm triggered from keypad 2 panic alarm triggered from keypad 3 auxiliary alarm triggered from keypad 4 keypad tamper 5 three invalid codes entered Information about the last alarm is displayed first If you press any key except for gt information about the previous alarm will be displayed Press the keys repeatedly to scroll back the alarm log 7 Viewing trouble log Press and hold down the 6 key for approx 3 seconds Information on troubles is presented on the numbered LEDs The LEDs indicate status when lit 1 OUT1 trouble 2 OUT2 trouble 3 OUTS trouble 4 230 V AC loss 5 battery trouble 6 no keypad supply 7 time not set 8 monitoring troubl
4. e Information about the last trouble is displayed first If you press any key except for gt information about the previous trouble will be displayed Press the keys repeatedly to scroll back through the trouble log 8 Viewing current troubles Press and hold down the 7 key for approx 3 seconds The trouble information is presented on LEDs designated by digits and on LEDs designated by letters The LEDs indicate status when lit 1 OUT1 trouble SATEL CA 6 5 2 OUT2 trouble 3 OUTS trouble 4 230 V AC loss 5 battery trouble 7 time not set 8 monitoring trouble A no voltage on telephone line lt gt B telephone line trouble wrong dial tone A telephone line trouble no dial tone D B control panel RAM memory error 9 Using selected user functions All the user functions are described in the full version of the user manual Described below are just a few selected functions 9 1 Changing your own code 1 2 3 Enter the code and confirm using key The Mr and TA LEDs will start blinking Press the 1 key Enter the new code 4 to 6 characters and confirm with key 9 2 Zone bypassing 1 2 3 4 5 Enter the code and confirm using key The BM i and CA LEDs will start blinking Press the 4 key The LEDs designated by digits indicate the current zone status LED extinguished the zone is not bypassed LED blinking
5. in the protected premises The installer shall define which zones are to be bypassed in such a case 3 1 Full arming Enter the code and confirm using key The partition s to which the user has access will be armed Note The user having the authority 7 can only activate partial armed mode the installer selected zones will be bypassed 3 2 Quick arming If your installer has enabled the Quick Arm feature you will be able to arm the system without using the code To quickly arm the system press in turn the keys 0 both partitions 1 partition A 2 partition B 3 3 Arming in silent mode During the silent armed mode the alarms from zones are only signaled on the keypad however the installer can program the control panel output so that it can provide information about alarms being signaled on the keypad After activating the silent armed mode the installer selected zones will be bypassed 1 Enter the code and confirm using key The R i and TA LEDs will start blinking 2 Press the 5 key The partition s to which the user has access will be armed in silent mode 4 Disarming and alarm clearing In order to disarm the partition and clear the alarm enter the code and confirm with the key 4 CA 6 SATEL 5 Triggering the alarm from keypad If your installer has enabled this feature the alarms can be triggered from the keypad as follows fire alarm press and hold down the key for approx 3 se
6. ling Beeps generated during operation 1 short beep pressing any number key 3 short beeps to signal arming disarming and or alarm clearing deactivating the 13 BI SWITCH type output by means of user functions 4 short beeps and 1 long beep to signal entering the service function menu activating the 12 MONO swiTcH or 13 Bl SWITCH type output by means of user functions finishing the function and exiting the user menu after confirming the entered data 2 long beeps an unknown code unavailable function or exiting the function without confirmation of the data entered after using key 3 long beeps refusal to arm some zones are violated or battery failure Events signaled by sounds 1 short beep every 3 seconds to signal service mode entry delay countdown 2 short beeps every 3 seconds trouble the sound signaling of trouble will stop after viewing the current troubles 5 short beeps zone violation CHIME 1 long beep every second fire alarm 1 long beep every 3 seconds exit delay countdown 5 long beeps zone violation the 4 DAY NIGHT type when the partition is disarmed the counter type triggers alarm after a preset number of violations when the partition is armed Continuous beep alarm Notes e Only installer selected events are signaled e Alarms will be signaled as long as programmed by the installer 2 Codes and users
7. ons 1 partition A 2 partition B Triggering the alarm from keypad fire alarm press and hold down the key for approx 3 sec press and hold down the key for approx 3 sec press and hold down the 0 key for approx 3 sec CODE panic alarm auxiliary alarm Starting the user functions CODE 1 Change own code CODE 2 Add user CODE 3 Erase user CODE 4 Bypass zones CODE 5 Arming silent CODE 6 Set time CODE 7 MONO outputs activate CODE 8 BI outputs switch CODE 9 Supply reset CODE 0 Telephone DOWNLOADING start Viewing current troubles Enabling disabling the CHIME signal press and hold down the 7 key for approx 3 sec press and hold down the 8 key for approx 3 sec
8. rapidly alarm memory illuminated briefly extinguishing every 2 seconds zone tampered flashing every 2 seconds tamper memory ud Yellow CA 6 KLED S only illustrates the functioning of the buzzer in the keypad When using the features available in the control panel the LEDs can also provide additional information 1 2 Keys The keys designated with digits and letters enable entering the code and data when using the keypad The key allows you to enter the user menu after entering the code enter the service mode after entering the service code exit some functions The key allows you to arm disarm and clear alarm after entering the code enter the service mode after entering the service code confirm the entered data Note The service mode is not available when there is an alarm or any partition is armed Press and hold down selected keys for about 3 seconds to view the alarm log view the trouble log view the current troubles enable disable the CHIME signal in the keypad signaling violation of selected zones with 5 short beeps ONO UO 2 CA 6 SATEL 9 change the keypad backlight mode only in CA 6 KLED S the number of short beeps indicates which backlight mode is enabled 1 no backlight 2 automatic backlight 3 permanent backlight 0 trigger the auxiliary alarm trigger the fire alarm trigger the panic alarm 1 3 Sound signa
9. repairs not authorized by the manufacturer shall void your rights under the warranty IMPORTANT The alarm system is not able to prevent a burglary or robbery Its purpose is to signal an emergency The system should be installed by qualified professionals who will inform you about the rules of using it and ensure its regular maintenance and testing We recommend regular testing of the alarm system to ensure that it will react properly in case of burglary or robbery SATEL s goal is to continually improve the quality of its products which may result in alterations of their technical specifications and firmware Current information on the introduced modifications is available on our website Please visit us at http www satel eu 1 Keypads description 1 1 Indicator LEDs hg Green illuminated 230 V AC mains and battery power OK blinking low battery extinguished 230 V AC power failure gt Green illuminated control panel occupies telephone line 5 Y Red letters A and B are used for partition identification L blinking alarm D Yellow letters A and B are used for partition identification illuminated partition armed blinking exit delay countdown r Yellow blinking trouble to check the cause of trouble press and hold down the 7 key f 6 Red digits correspond to zone numbers extinguished normal zone status blinking slowly zone bypassed illuminated zone violated blinking
10. the zone is bypassed Using the keypad enter the number of zone which is to be bypassed if it is not bypassed or unbypassed if it is bypassed Having selected the zones to be bypassed unbypassed press the key Notes For security considerations the installer can reduce the number of zones that the user is authorized to bypass Bypassing the zones reduces the level of security Prior to arming make sure that there are no accidentally bypassed zones which can allow an intruder to gain access to the protected area despite the system being armed If a zone is bypassed because of its malfunctioning e g because of detector trouble call the service technician immediately to repair the fault 6 CA 6 SATEL 10 Quick keypad operating instructions illuminated 230 V AC mains and battery power OK blinking low battery extinguished 230 V AC power failure tag illuminated control panel occupies telephone line gt blinking alarm Ko illuminated partition armed blinking exit delay countdown A blinking trouble the LED illustrates the functioning of the buzzer in the keypad Viewing alarm log press and hold down the 5 key for approx 3 sec Viewing trouble log press and hold down the 6 key for approx 3 sec Arming Disarming Alarm clearing O both partiti

Download Pdf Manuals

image

Related Search

Related Contents

User Guide for Harassment Policy  Armoires métalliques associables industrielles IS2 Principales  KULED551HDA User Manual  Gigaset S4 professional an HiPath Cordless Office  PC接続によるファームウェアアップデート方法  Manual de Utilização HYDROMETTE COMPACT  Sony CMT-SBT300W  Parasound HCA-1500A Stereo Amplifier User Manual  