Home
CompuScope SDK for MATLAB Manual
Contents
1. PP os ttrigger data Amount of the pre trigger data is equal or bigger then Segment Size Depth CompuScope SDK for MATLAB for Windows 23 Technical Support We offer technical support for all our Software Development Kits In order to serve you better we have created a web based technical support system that is available to you 24 hours a day By utilizing the internet to the fullest we are able to provide you better than ever technical support without increasing our costs thereby allowing us to provide you the best possible product at the lowest possible price To obtain technical support simply visit www gage applied com support support_form php Please complete this form and submit it Our form processing system will intelligently route your request to the Technical Support Specialist TSS most familiar with the intricacies of your product This TSS will be in contact with you within 24 hours of form submittal In the odd case that you have problems submitting the form on our web site please e mail us at tech support gage applied com As opposed to automatic routing of technical support requests originating from the GaGe web site support requests received via e mail or telephone calls are routed manually by our staff Providing you with high quality support may take an average of 2 to 3 days if you do not use the web based technical support system Please note that Technical Support Requests
2. Descriptions of all configuration parameters are listed below Throughout the parameter assignments the CsMI_ Translate M file is used Using a context field this function translates descriptive strings into parameter index values for convenience and code readability For instance instead of remembering that the CompuScope mode index values for Single Dual Quad and Octal modes are 1 2 4 and 8 the user can simply translate these strings using CsMI_Translate If any of the configuration parameters are not assigned their values will be assigned to default values by the driver The Channel field within the chan structure and the Trigger field within the trig structure however are mandatory Acquisition Parameters acq SampleRate The sampling rate in Hz acq ExtClock A flag that activates external clocking when non zero acq Mode The CompuScope mode Single Dual Quad or Octal acq SegmentCount The number of segments to be acquired acq Depth The post trigger depth acq SegmentSize The size of memory allocated for the segment acq TriggerTimeout The trigger time out value in microseconds acq TriggerDelay The trigger delay value in samples acq TriggerHoldoff The trigger holdoff value in samples acq TimeStampConfig A flag that when non zero resets the Time Stamp counter at the beginning of an acquisition 10 CompuScope SDK for MATLAB for Windows Channel Parameters The chan
3. The documentation for each call will tell which return values are required and which can be ignored Generally speaking if there is one return value it can be ignored If there is more than return value only the rightmost value can be ignored A brief description of any CsMI_ Xxx M file may be obtained simply by typing help CsMI_Xxx at the MATLAB command prompt CompuScope SDK for MATLAB for Windows 9 Chapter 3 Detailed Description of CompuScope Main M files Setup m Within all Main M file programming examples values of configuration parameters are assigned within an M file called Setup m which is called by every Main MATLAB M file Setup m is called with an argument of the handle of the CompuScope system to be configured Next Setup m calls CsMI_GetSysteminfo m to obtain information about the CompuScope system Setup m proceeds to assign values for the three main parameter sets the acquisition parameters the channel parameters and the trigger parameters Each parameter set has its own associated variable structure acg chan and trig respectively that are used as arguments by the Configuration M files CsMI_ConfigureAcquisition m CsMI_ConfigureChannel m and CsMI_ConfigureTrigger m respectively The Configuration functions are used to assign parameter values within the CompuScope driver However the parameter setting values are not actually sent to the CompuScope hardware until CsMI_Commit is invoked
4. received via e mail or by telephone will take an average of 2 to 3 days to process It is faster to use the web site When calling for support we ask that you have the following information available 1 Version and type of your CompuScope SDK and drivers The version numbers are indicated in the About CD screen of the CompuScope CD Version numbers can also be obtained by looking in the appropriate README TXT files 2 Type version and memory depth of your CompuScope card 3 Type and version of your operating system 4 Type and speed of your computer and bus 5 If possible the file saved from the Information tab of the CompuScope Manager utility 6 Any extra hardware peripherals i e CD ROM joystick network card etc 7 Were you able to reproduce the problem with standalone GaGe Software e g GageScope GageBit CompuScope SDK for MATLAB for Windows 24 GaGe Products For ordering information see Gage s product catalog or visit our web site at http www gage applied com CompactPCI Bus Products PCI Bus Products CompuGen PCI CompuGen ISA Application Software Software Development Kits Instrument Mainframes CompuScope 82GC CompuScope 14100C CompuScope 1610C CompuScope 3200C CompuScope 1610 CompuScope 1602 CompuScope 14200 CompuScope 14105 Octopus multi channel digitizer family CompuScope 12400 CompuScope 1220 Cobra CompuScope family BASE 8 CompuScope Compu
5. the Getting Started with MATLAB manual supplied to you by The MathWorks Inc before starting any program development for the CompuScope cards It is also assumed that you are familiar with PCs and Microsoft Windows and that you have correctly installed the CompuScope Windows drivers This manual will use the terms CompuScope SDK for MATLAB for Windows and CompuScope MATLAB SDK interchangeably Please note that this manual is not intended as a reference for any software other than the CompuScope SDKs for MATLAB for Windows If you did not receive the correct guide please contact the factory for a replacement Please note that although 64 bit Gage CompuScope drivers are available for 64 bit Windows Operating systems the CompuScope MATLAB SDK does not support 64 bit MATLAB To maintain the accuracy of the information contained herein we reserve the right to make changes to this manual from time to time 4 CompuScope SDK for MATLAB for Windows Chapter 1 Installation of CompuScope MATLAB SDK If you purchased the CompuScope MATLAB SDK you will have been shipped a software key that allows installation of the SDK from the GaGe CompuScope CD Simply select the installation of the CompuScope MATLAB SDK from the CompuScope CD and enter the software key when prompted By default the CompuScope MATLAB SDK will install itself in O S system drive Program Files Gage CompuScope CompuScope MATLAB SDK It i
6. there is less preceding valid trigger data than the maximum possible amount of pre trigger data If transfer of invalid data were requested the driver would return an actual start address that is equal to the address of the first valid pre trigger point More pre trigger data could have been acquired using Trigger Holdoff at the expense ignoring and so possibly missing triggers The final sequence shows acquisition in the case of a trigger that occurs long after Segment Start so that all memory allotted for pre trigger data has been filled up In fact the sequence shows that still more pre trigger data were acquired but were overwritten by post trigger data Trigger hold off plus i Natural Pre ad Segment size Overwritten i Trigger delay Depth lt Post trigger data gt Start capture General format of the segment _ Trigger hold off plus F natural pre trigger lt lt Segment size gt Overwritten data q Trigger delay Depth Post trigger data gt Start capture 2 Usually if trigger delay is not zero o Segment size Depth La Tigger hold off plus 1 natural pre trigger lt Segment size gt Y Start Capture Post trigger data gt Amount of pre trigger data due to hold off and natural pre trigger is e Trigger hold off plus natural pre trigger gt less then Segment size Depth l p i Segment size Overwritten data Start capture
7. ESIZO iii A A dd ada 20 Trigger Holdoff eeri dai 21 Trigger Delay icon tienen ilatina dead 21 CompuScope Acquisition Timing Diagram cccccccccesesessesesesseseseseseescsessesesessceeseneeseseesescseneeaeeceeeseas 22 Representative Acquisition SEQUENCES cscccsceseseseeseseseseseseceeceseeceseseseeeesencaeseeeceeseeeaeeeeeeeeaeeees 23 TECHNICAL SUPPORT ssisecscsesscsccccccsssocsesscccssssesessssseccusssdesvess0uesicscsosssoietsuccoscedesvoasiaaccssssustactesdeddescsssdvesiases 24 GAGE PRODUCTS sssscveccscciscsisccssssdessondsencsatesecesoasutecesesedendsassanusivunseuserssactesnensvopensuaceseceusecssessdedeteusssesendsorate 25 CompuScope SDK for MATLAB for Windows 3 Preface This manual is meant to serve as an aid to engineers using the CompuScope series of high performance data acquisition cards in the MATLAB 6 5 for Windows environment The CompuScope SDK for MATLAB for Windows supports all GaGe CompuScope cards PCI and CompactPCl PXI Specific hardware features that are available in the SDK sample programs however may not be supported by your CompuScope model Please refer to the CompuScope Hardware Manual for information specific to your CompuScope card in order to determine the capabilities of your CompuScope model Throughout this manual it is assumed that you are familiar with the MATLAB programming environment If you do not feel comfortable with MATLAB it is highly recommended that you go through
8. GaGe CompuScope Software Development Kit SDK for MATLAB for Windows User s Guide CompuScope Driver Version 4 10 For MATLAB 6 5 P N 0045119 Reorder MKT SWM CSML08 0807 O Copyright Gage Applied Technologies 2005 2006 Ninth Edition July 2008 COMPUSCOPE GAGESCOPE AND COMPUGEN are trademarks or registered trademarks of Gage Applied Technologies MICROSOFT WINDOWS WINDOWS 2000 and WINDOWS XP are registered trademarks of Microsoft Corporation MATLAB is a registered trademark of The MathWorks Inc Other company and product names mentioned herein may be trademarks or trade names of their respective owners Changes are periodically made to the information herein these changes will be incorporated into new editions of the publication Gage Applied Technologies may make improvements and or changes in the products described in this publication at any time Copyright O 2005 2006 2007 2008 Gage Applied Technologies All Rights Reserved including those to reproduce this publication or parts thereof in any form without permission in writing from Gage Applied Technologies How to reach GaGe Product Support Toll free phone 800 567 4243 Toll free fax 800 780 8411 To reach GaGe Product Support from outside North America Tel 1 514 633 7447 Fax 1 514 633 0770 E mail prodinfo gage applied com Web site http www gage applied com On line Support Request Form www gage applied com support support_form p
9. SDK M File CSSSM DLL Windows Application Level Windows Kernel Level GaGe CompuScope drivers GaGe CompuScope Hardware At the lowest level is the CompuScope hardware which is installed within a slot that is connected to the host PC The CompuScope hardware is directly controlled by the CompuScope Windows drivers The drivers reside at the Windows Kernel level which allows direct low level access to CompuScope hardware registers and to physical PC RAM The Kernel level drivers communicate with Windows Applications through a Dynamically Linked Library DLL called CSSSM DLL Communications through CSSSM DLL use the CompuScope Applications Programming Interface API which is the set of C subroutine calls that allows control of all CompuScope functionality Above CSSSM DLL is an intermediate DLL called CsMI DLL This DLL contains a single MATLAB MEX function called CsMI that is used to control GaGe CompuScope hardware from MATLAB Different index arguments to CsMI from MATLAB allow different operations to be performed on the CompuScope hardware 6 CompuScope SDK for MATLAB for Windows For convenience all subroutine calls to CsMI are wrapped within CsMI M files with descriptive names which makes the MATLAB coding more readable and removes the requirement of keeping track of the required index values All CsMI M file names have the form CsMI_Xxx m where Xxx describes its functionality Most users should find it unneces
10. Scope 3200 CompuGen 4300 4302 CompuGen 8150 8152 CompuGen 11G 11G2 CompuGen 1100 CompuGen 3250 GageScope GageBit CompuGen for Windows 8 bit 2 GS s Analog Input Card 14 bit 100 MS s Analog Input Card 16 bit 10 MS s Analog Input Card 32 bit 100 MHz Digital Input for CompactPCI Bus 16 bit 10 MS s Analog Input Card 16 bit 2 5 MS s Analog Input Card 14 bit 200 MS s Analog Input Card 14 bit 105 MS s Analog Input Card Up to 8 channels on a single slot PCI card 12 or 14 bit resolution 10 to 125 MS s 12 bit 400 MS s Analog Input Card 12 bit 20 MS s Analog Input Card 8 bit up to 2 GS s Analog Input Card 8 bit up to 500 MS s Analog Input Card 32 bit 100 MHz Digital Input for PCI Bus 12 bit 4 channel 300 MHz Analog Output Card 12 bit 8 channel 150 MHz Analog Output Card 12 bit 1 GHz Analog Output Card 12 bit 80 MS s Analog Output Card 32 bit 50 MHz Digital Output Card World s Most Powerful Oscilloscope Software Digital Input Output Software Arbitrary Waveform Generator Software for Windows CompuScope SDK for C C for Windows CompuScope LabVIEW SDK for Windows CompuScope MATLAB SDK for Windows CompuGen SDK for C C CompuGen LabVIEW SDK CompuGen MATLAB SDK LapScope 1 LapScope 2 Instrument Mainframe 7500 Instrument Mainframe 2020E Instrument Mainframe 4000 Instrument Mainframe 8000C CompuScope SDK for MATLAB for Windows 1 slot PCI Expansion Chassis for CompuScope and CompuGen car
11. Scope hardware gt 16 MB GageComplexTrigger m An M file that illustrates usage of complex triggering using multiple on board trigger engines if available GageMultipleSystems m An M file that operates two independent CompuScope systems each with their own settings and output DAT files 8 CompuScope SDK for MATLAB for Windows DisplayData m An M file that plots data from DAT files acquired in Single Record Mode ReadMrDataFiles m An M file that plots data from DAT files acquired in Multiple Record Mode All acquired data are stored in DAT ASCII data files These files contain a file header that is between two lines of minus signs The acquired data are then listed as a single column of data Data are stored in volts by default but may alternately be stored as raw ADC data The DAT file format is described in more detail in the documentation provided with the GaGe File Converter utility which allows conversion between ASCII DAT files and GageScope SIG binary files Not all possible CompuScope operation configurations are covered by the Main M files For instance there is an M file that handles deep acquisitions and an M file that handles acquisitions from two CompuScope systems However there is not an M file that handles deep acquisitions from two CompuScope systems For both these functionalities the user must study GageDeepAcquisition m and GageMultipleSystems m and then appropriately combine them to create an M file tha
12. Start point In GageAcquire m the transfer length is set equal to the SegmentSize so that all segment data are returned The transfer start is set equal to the Trigger Holdoff so that all valid pre trigger data are transferred These two values SegmentSize and Holdoff were set previously within Setup m but are obtained using CsMI_QueryAcquisition Next the acquisition is initiated on the CompuScope system using CsMI_Capture The CompuScope hardware then begins acquiring pre trigger data and awaiting a trigger event The acquisition terminates after the trigger event occurs and the CompuScope system has acquired the requested amount of pre trigger data The state of the CompuScope system is queried using CsMI_QueryStatus handle until the acquisition has completed Once the acquisition is complete data are transferred to MATLAB using CsMI_ Transfer Within GageAcquire m CsMI_Transfer is configured to first transfer the raw integer ADC data and then to convert these data to voltage values These converted voltage values are then returned by CsMI_Transfer For faster repetitive capture performance CsMI_Transfer may alternately be configured to transfer raw ADC code data as integers 12 CompuScope SDK for MATLAB for Windows Mathematical operations may not be performed on these integer values however without first converting them to double values After transfer the data are stored to ASCII DAT files with the appropriate header informati
13. al RAM which is a section of the hard drive that Windows treats like PC RAM Usage of virtual RAM causes the hard drive to spin and slows down execution For large enough data sets MATLAB will simply refuse to download the data at all In order to avoid trying to keep large data sets in MATLAB at one time GageDeepAcquisition m manages deep acquisitions by dividing them up into more manageable data pages whose size is denoted by the chunksize variable The M file does initialization configuration setting and acquisitions as usual After the acquisition however data are downloaded in pages of size chunksize Each page is stored in its own ASCII DAT file called DeepAcquisition_CHxx yyyy dat where xx is the channel number and yyyy is the page number One complete data file for the entire acquisition may easily be created by removing the header for each DAT file and combining them in order by page number The user may easily replace data storage with analysis and or display to suit their requirements Users should always use a similar data paging scheme for downloading large amounts of data and should never attempt to download large amounts of data at one time 14 CompuScope SDK for MATLAB for Windows GageComplexTriggerAcquire m GageComplexTriggerAcquire m is a Main M file that illustrates complex triggering Some CompuScope models are equipped with two on board trigger engines that can be used for complex triggering On these models the t
14. are recognized Trigger delay amount of time after detecting a trigger event before start of decrementing of the depth counter Expiring of the depth counter ends the segment acquisition Segment size gt Depth the only limitation Maximum amount of the pre trigger data Segment size Depth 22 CompuScope SDK for MATLAB for Windows Representative Acquisition Sequences The diagram below illustrates important representative acquisition sequences that are presented for key acquisition requirements The first sequence shows a generalized acquisition with data collected during all acquisitions phases illustrated overwritten pre trigger data available pre trigger data data acquired during the Trigger Delay and post trigger data The second sequence shows an acquisition using a trigger delay where the Segment Size is made equal to the Depth This acquisition sequence is useful for applications where the signal region of interest occurs long after the trigger event as is often the case for Time Domain Reflectometry methods such as ultrasonics radar and lidar The third sequence shows the acquisition in the case of a rapidly occurring trigger In this case the Segment size has been set bigger than the Depth However the trigger event occurred so rapidly after the start of the acquisitions that there was insufficient time to fill all of the memory allotted for pre trigger data which is Segment Size Depth samples Consequently
15. cope driver and the CompuScope hardware Obtain the handle to the first available CompuScope system in the PC Pass the desired configuration settings to the driver with a call to Setup m KR OD gt Pass the configured settings to the CompuScope hardware using the CsMI_Commit subroutine 5 Start the CompuScope hardware to digitize data into its on board memory and await a trigger event 6 Continuously check to see if the CompuScope hardware has finished capturing the current record 7 Download the data of interest from the CompuScope hardware to MATLAB array variables 8 Store the acquired data to a DAT ASCII data file A list of all CompuScope Main M files is given below with a brief description of the functionalities GageSimple m A simple M file used to verify correct CompuScope driver and MATLAB SDK operation No adjustments are possible and default CompuScope settings are used GageAcquire m The simplest M file with full configuration control of CompuScope settings that illustrates usage of CompuScope Single Record Mode An error occurs upon entry of invalid settings GageCoerce m An M file that is just like GageAcquire m except that invalid settings are coerced to the closest valid values GageMultipleRecord m An M file that acquires and stores captured records when operating a CompuScope system in Multiple Record Mode GageDeepAcquisition m An M file that acquires and manages large data captures from Compu
16. cope system for a total of three CompuScope systems CompuScope systems are addressed from MATLAB by first acquiring a handle for the system which is an integer value that uniquely describes the CompuScope system After usage of the system is complete the user must release the handle so that it is free for usage by other processes By obtaining handles for different systems a single MATLAB M file may simultaneously operate different CompuScope systems Alternately separate MATLAB M files may operate independently and simultaneously by calling handles for separate CompuScope systems Different M files may even access the same hardware as long as one M file frees the system handle before the other M file obtains it since different applications may not simultaneously access the same CompuScope system While most Main example M files access only a single CompuScope system understanding the CompuScope system structure easily allows users to extend these Main M files to multiple system operation CompuScope SDK for MATLAB for Windows 7 Overview of CompuScope Main M files The Main M files are intended to be convenient starting points around which users can develop customized MATLAB software for their digitizer application Users can construct more complex M files themselves by using the existing Main M files as a guide to combining their functionalities The basic algorithm for all of the Main M files is the following Initialize the CompuS
17. ded Using the Trigger Delay feature however only the data of interest are retained in CompuScope memory CompuScope Acquisition Timing Diagram The timing diagram below is provided as an aid for understanding the timing of events during the acquisition of a segment or record The pseudo signals are indicated as HIGH when the labeled function is active A CompuScope system always acquires from the beginning of the Segment Start pulse and continues until the Depth counter s count down has expired The memory allotted to the acquisition is equal to the Segment Size and is arranged in a circular fashion Notice that raw trigger events are ignored until the Trigger Holdoff time has elapsed Note also that although pre trigger data are acquired throughout the time between Segment Start and the Trigger Event most of the acquired pre trigger data have been overwritten in the diagram below and only a small fraction are available for download lt Segment size gt General format of the segment Trigger delay Depth 4 Post trigger data gt Segment start Capture i 1 I I Trigger Holdoff gt i i Trigger enable Raw trigger Natural id Trigger j Trigger delay el Depth counter enable Segment end Trigger holdoff amount of time after start of the capture of the segment before trigger events
18. ds 2 slot PCI Expansion Chassis for CompuScope and CompuGen cards 4 slot Portable Instrument Mainframe for CompuScope and CompuGen cards 18 PCI slot and 1 ISA slot Instrument Mainframe for CompuScope and CompuGen cards 5 PCI X and 1 PCI slot Instrument Mainframe for CompuScope and CompuGen cards 7 cPCI PXI slot Instrument Mainframe for CompuScope CompactPCl PXI cards 25
19. e Voltage conversion may then be done at leisure in post processing Raw ADC code waveform data may be converted to voltage data for all CompuScope models using the following equation Offset ADC_Code F ull Scale Input Voltage Resolution 2 Voltage DC_Offset The Offset and Resolution for the CompuScope system may be obtained programmatically using various SDK tools The DC offset settings supported only on newer CompuScope models must be added For instance for the CompuScope 82G Offset 127 and Resolution 128 Let us assume that the user has selected the 1 Volt Input Range for a Full Scale Input Range of 2 Volts Let us further assume that the user has applied a 200 mV offset For this example therefore the voltage conversion equation becomes volage 2 ADE Code Vol 128 Depth and Segment Size On all CompuScope models on board acquisition memory is arranged as a circular buffer for Single Record acquisitions This means that when the CompuScope is storing acquired data and it reaches the end of the memory the memory counter rolls over Data storage wraps around the memory and starts digitizing into the beginning of memory The end of an acquisition is always initiated by the trigger event after which the requested number of post trigger data points is acquired and then the acquisition terminates This circular memory architecture allows the CompuScope to accumulate an amount of pre trigger data of up
20. g values Single to activate 8 bit digital input mode Dual to activate 16 bit digital input mode Quad to activate 32 bit digital input mode The CS3200 and CS3200C provide different digital input signal level protocols depending on the model Different digital input protocols are selected by setting appropriate values of chan i InputRange within Setup m and using the following input range values 2500 to activate CMOS digital voltage levels 1500 to activate TTL digital voltage levels 2000 to activate ECL digital voltage levels 3000 to activate PECL digital voltage levels 0 to activate LVDS digital voltage levels The CS3200 and CS3200C allow inversion of the sampling clock so that digital samples are acquired on the falling edge of the clock signal rather than on the rising edge In order to select the falling edge the desired acg Mode must be ORed with the hexadecimal value 0x800 Consequently strings with the CsMI_Translate m file may not be used and acq Mode must be assigned to the following numerical values 2049 to activate 8 bit digital input mode with clock inversion 2050 to activate 16 bit digital input mode with clock inversion 2052 to activate 32 bit digital input mode with clock inversion Advanced Main M files The MATLAB SDK may contain Advanced M files in addition to the documented Main M files Usage of some of these files may require special CompuScope hardware options on board firmware processing images or a spec
21. ger event to occur on a CompuScope system CompuScope SDK for MATLAB for Windows 17 CsMI_FreeAllSystems CsMI_FreeAllSystems aborts any acquisitions and frees all CompuScope systems that are currently in use CsMI_FreeSystem CsMI_FreeSystem frees a CompuScope system Once a system is freed it may be used by other applications CsMI_GetErrorString CsMI_GetErrorString translates the error code returned by other CsMI_Xxx functions into a descriptive error message CsMI_GetExtendedOptions Extended options are optional programmed firmware images CsMI _GetExtendedOptions returns information about the optional programmed firmware images available on a CompuScope system CsMI_GetSystem CsMI_GetSystem returns a handle that uniquely identifies a CompuScope system CsMI_GetSystemCaps CsMI_GetSystemCaps returns information about the capabilities of a CompuScope system While complicating a MATLAB program this function may be used to allow the program to support any possible configuration of CompuScope hardware MATLAB SDK Main M files do not use this function CsMI_GetSystemCaps CsMI_GetSysteminfo returns static information about a CompuScope system CsMI_Initialize CsML_Initialize initializes a CompuScope system and is typically the first CompuScope call made in a program CsMI_QueryAcquisition CsMI_QueryAcquisition returns information about a CompuScope system CsMI_QueryChannel CsMI_QueryChannel returns informat
22. hp Table of Contents PREFAGE NO 4 CHAPTER 1 INSTALLATION OF COMPUSCOPE MATLAB SDK oonononccccnoncnonccnoncccnccnonoconcoccccocaosos 5 CHAPTER 2 OVERVIEW OF COMPUSCOPE MATLAB SDK scsscssssssssssessssesecessesersssesecessesers 6 OVERVIEW OF COMPUSCOPE MAIN M FILES cccssessseesesescseecesesceseecacecsacsesececaescacecsececneeceatecseceeaeeeeatees 8 OVERVIEW OF COMPUSCOPE CSML M FILES e ccccsseseseesesescscecesesceeeecaeecaescsececaeecsacscseecaeeeeatecseceeaeeeaters 9 CHAPTER 3 DETAILED DESCRIPTION OF COMPUSCOPE MAIN M FILES oomooooooo 10 Setup Maia Sees A 10 EEE AS 11 GAG CACQUIFE Mi a 12 E A AN 13 CENT AA 13 CENT T NN 14 Gage Complex TrigQerACQuire 111 ecccscecssesssseseseesesesessesesesesenesseceseseseesenssaesesecsesenseaeseseesesenseaeaeeeeneas 15 CEI NISSAN 15 DISPIAY DALAT isccseclessiseladisvieateesescustusadeadeesaseesbectdeadeesascusbacaceeseesaseesbenddeesasseseeddned deo saseesee deed denied 15 ReadMrDalaFleS Mii iii 15 Digital Input COMPUSCOPE CAMAS sceeceesesessesesesseseseseesesesensesesesesceseucsaesesececaeeceaeecseceeaeeceaeeeeeeeaeeees 15 Advanced Maim MANOS 000 dit 16 CHAPTER 4 OVERVIEW OF CSML M FILES s ccsseeeeeeeseeeeeeeeceeeeeeseeeeaeeeaeeeeeneeeneeeeeeeeees 17 CHAPTER 5 SPECIAL TOPICS iio al add iia 20 Converting from CompuScope ADC Code to Voltages sccscscecescsssseseteeseseseneeseseeeeeeseneeseeeeeeeens 20 Depth and SOIMEN
23. ial driver version These M files are located in the adv folder and are provided as is with limited documentation in the form of an accompanying explanatory text file 16 CompuScope SDK for MATLAB for Windows Chapter 4 Overview of CsMI M Files Please refer to the MATLAB SDK help for a more detailed description of CsMI M file operation At the MATLAB command prompt type help and the name of the CsMI M file e g help CsMI_AbortCapture CsMI_AbortCapture CsMI_AbortCapture aborts an acquisition on a CompuScope system CsMI_Capture CsMI_Capture begins an acquisition using the current acquisition parameters on a CompuScope system CsMI_Commit CsMI_Commit sends the acquisition channel and trigger parameters that are in the driver to a CompuScope system CsMI_ConfigureA cquisition CsMI_ConfigureAcquisition sets the acquisition parameters for a CompuScope system CsMI_ConfigureChannel CsMI_ConfigureChannel sets the channel parameters for a CompuScope system CsMI_ConfigureFir CsMI_ConfigureFir sets the Finite Impulse Response parameters for a CompuScope system Note that the CompuScope system must have an optional FIR image available and loaded for this function to work CsMI_ConfigureTrigger CsMI_Contfigure Trigger sets the trigger parameters for a CompuScope system CsML ErrorHandler CsMI_ErrorHandler processes errors from other CsMI_Xxx calls CsMI_ForceCapture CsMI_ForceCapture forces a trig
24. ion about the specified channel in a CompuScope system 18 CompuScope SDK for MATLAB for Windows CsMI_QueryStatus CsMI_QueryStatus queries the driver for the current acquisition status of a CompuScope system CsMI_QueryTrigger CsMI_Query Trigger returns information about the specified trigger in a CompuScope system CsMI_ReadDataFile CsMI_ReadDataFile reads data from ASCII DAT files and adjusts the data to account for alignment issues using the Start address and Data length fields saved in the ASCII file header CsMI_ResetTimeStamp CsMI_ResetTimeStamp resets the time stamp counter associated with a CompuScope system CsMI_SaveFile CsMI_SaveFile saves a buffer of data acquired by a CompuScope system to an ASCII DAT file CsMI_Transfer CsMI_Transfer transfers data for one channel from a CompuScope system CsMIL Translate CsMI_Translate is provided for convenience and allows conversion of descriptive string into constant values that are required by the driver thereby not requiring the user to look up the values in tables CompuScope SDK for MATLAB for Windows 19 Chapter 5 Special Topics Converting from CompuScope ADC Code to Voltages SDK sample programs are configured to save or display CompuScope waveform data that have been scaled so that the sample values are in Volts The user may want to bypass the voltage conversion step however in order to achieve the best repetitive capture performanc
25. lities For a more CompuScope SDK for MATLAB for Windows 13 detailed discussion of the relationship between SegmentSize and Depth please see Chapter 5 Special Topics When executed GageMultiple Record m first initializes and configures the CompuScope system as in GageAcquire m Next a single Multiple Record acquisition is performed After acquisition the M file goes into a loop that downloads each Multiple Record from each active channel and stores the record data to ASCII data files Newer CompuScope models such as the CS14200 CS14105 and CS12400 support Time Stamping This feature registers an on board counter value for each Multiple Record trigger event that indicates its time of occurrence Time 0 is the time at which the time stamping counter was last reset The Time Stamp counter is reset to zero at the beginning of GageMultipleRecord m If the CompuScope system is equipped with on board Time Stamping GageMultipleRecord m downloads Time Stamp data and stores each Time Stamp in the corresponding ASCII DAT file Otherwise a 0 is stored as the Time Stamp value GageDeepAcquisition m GageDeepAcquisition m is the Main M file for large acquisitions from a single CompuScope system The definition of large varies with system configuration but is roughly about 16 MegaBytes For small acquisitions MATLAB is fully capable of downloading the entire acquisition into PC RAM For larger acquisitions the host PC will begin to use virtu
26. on The DAT files have names of the form Acquire_CHx dat where x is the channel number Waveform data are also displayed in a simple MATLAB plot window While GageAcquire m simply stores and displays waveform data the end of the program may be easily modified by the user to instead manage the data according to the requirements of the application For instance waveform data may be immediately analyzed in real time using MATLAB s extensive math libraries GageCoerce m GageCoerce m is identical to GageAcquire m except that in the event of invalid configuration setting entries the M file will not stop with an error message Instead of stopping if invalid configuration settings are entered the M file will coerce the settings to values that are available on the current CompuScope system When coercion occurs a message is printed which indicates that a parameter was coerced and the current acquisition channel and trigger parameters are printed to the console Current active parameter settings may be queried using the Query CsMI files Waveform data are stored in DAT files named Coerce_CHx dat where x is the channel number GageMultipleRecord m GageMultipleRecord m is the Main M file for Multiple Record capture from a single CompuScope system Multiple Record mode allows multiple waveforms to be rapidly acquired and stacked in on board CompuScope memory For instance a CompuScope card with 32 MegaSamples of on board memory may acquire 16 000 rec
27. ope hardware will ignore trigger events after acquisition has begun and pre trigger data are being acquired Without a non zero Trigger Holdoff value there is no guarantee that a given number of pre trigger samples will be acquired This is because a trigger event may occur immediately after acquisition leading to a very small number of pre trigger points By ignoring trigger events for a time equal to the specified Trigger Holdoff value the accumulation of a number of pre trigger points equal to the Trigger Holdoff setting is guaranteed The downside of ensuring pre trigger data with a non zero Trigger Holdoff value is that triggers are ignored so that important trigger events may be missed For instance in lightning monitoring applications researchers usually want to acquire pre trigger data These data give information about signal behavior immediately preceding the lightning strike which triggers the CompuScope hardware Lightning strikes may occur very close together in time however and missing a lightning pulse is much worse than missing pre trigger data Consequently lightning testers should not use Trigger Holdoff but should simply accept acquisitions of only the amount of pre trigger data that naturally occur between triggers Generally speaking therefore the user must decide whether to use Trigger Holdoff based on the application Trigger Delay New generation PCI CompuScope models such as the CS14200 CS14105 and CS12400 su
28. ords of 2 000 samples each in Multiple Record Mode Strictly speaking depending on the CompuScope model this relation may not exactly apply because of slight inter record padding requirements Between successive acquisitions the CompuScope acquisition engine is re armed by the hardware with no CPU interaction required Consequently in Multiple Record Mode a CompuScope card is capable of capturing bursts of trigger that repeat at rates of 100 000 triggers per second and more The number of records or segments to acquire is set using the SegmentCount parameter This is set to 1 within the single Setup m file that is provided and so must be raised for a large record count If SegmentCount exceeds the maximum possible number of records which is roughly equal to the available acquisition memory divided by the Depth then an error will occur If coercion had been used in this case then the actual number of records would have been set equal to its maximum possible value The SegmentSize parameter is used to control the size of each Multiple Record segment For newer CompuScope hardware this may be set larger than the Depth parameter so that pre trigger data may be acquired Older CompuScope models do not support pre trigger data in Multiple Record Mode Consequently setting SegmentSize to a value different from Depth will cause an error Please refer to your CompuScope Hardware Manual for information specific to your CompuScope model s capabi
29. plot displays the expected waveform data in order to confirm that the MATLAB SDK is operating correctly GageAcquire m GageAcquire m is the Main M file for Single Record capture from a single CompuScope system In the event of a multiple CompuScope system the M file only operates the first card in the system The M file first initializes the drivers using CsMI_Initialize then obtains the handle to the first available CompuScope system using CsMI_GetSysteminfo Next Setup m is called which assigns values to each configuration parameter and passes these values to the drivers After Setup m CsMI_Commit is called which actually passes the parameter values that have been set in the driver to the CompuScope hardware Invalid settings cause an error and an error message is displayed Users who prefer the M file to continue operating upon invalid setting entry should use GageCoerce m which will coerce invalid entries to valid entries and continue running Next the transfer structure is filled with parameters that will determine how the data are transferred to MATLAB from CompuScope memory after acquisition Parameters within the transfer structure are transfer Segment The segment number to transfer starting from 1 transfer Start The point from which to start data transfer Zero indicates the trigger address Enter a negative value in order to download pre trigger data transfer Length The number of points to transfer starting from the
30. pport a feature called Trigger Delay This feature is useful for situations where the signal portion of interest occurs long after the trigger event Normally with a Trigger Delay of zero the trigger event activates count down of the post trigger depth counter which was preloaded with the post trigger depth The counter is decremented by one count for each sample acquired after the trigger event When the counter value reaches 0 the acquisition is terminated In this way the CompuScope acquires a number of samples equal to the depth after the trigger event A non zero Trigger Delay value is used to delay the beginning of the countdown of the post trigger depth counter The Trigger Delay value sets the number of samples that the CompuScope hardware will wait after the trigger event occurs before beginning the count down of the depth counters The SegmentSize may be set equal to the depth so that the CompuScope hardware need not waste memory by storing data that are not of interest CompuScope SDK for MATLAB for Windows 21 As an example consider a signal where the feature of interest is 20 000 samples long but begins 100 000 samples after the trigger event In this case the SegmentSize and Depth should be set to 20 000 The Trigger Delay value should be set to 100 000 Without the Trigger Delay feature the user would be forced to set the Depth to 120 000 Samples and waste 100 000 Samples of memory even though only the last 20 000 were downloa
31. rig Level The trigger level as a percentage 100 to 100 of the trigger source input range trig Source The trigger source A Trigger Channel Source 1 2 External or Disable trig ExtCoupling The input coupling of the external trigger input AC or DC trig ExtRange The external trigger full scale input range in millivolts For instance set to 10000 for the 5 Volt input range GageSimple m GageSimple m is not intended as a starting point for customer applications but is a simple test program to confirm correct operation of the CompuScope hardware Windows drivers and MATLAB SDK GageSimple m grabs the handle to the first available CompuScope system and does a single acquisition using the driver defaults for all configuration parameters The driver defaults are a set of default configuration parameters that are tailored to each CompuScope hardware model After acquisition acquired data for Channel 1 are displayed in a simple MATLAB plot window CompuScope SDK for MATLAB for Windows 11 This M file operates only on a single CompuScope card In the event of a multi CompuScope system the M file only addresses the first card in the first system Again GageSimple m should only be used to test hardware and software integrity and should not be developed into a custom application M file since there are better Main M files for this purpose Simply check that no errors occurred during execution of GageSimple m and that the MATLAB
32. s recommended that you use the default installation location The CompuScope MATLAB SDK will create three sub folders called Main CsMI and Adv These folders respectively contain Main M file programming examples CsMI M files that are the building block function calls from which the Main M files are constructed and advanced M files for special non standard CompuScope functionality If you require more detailed installation instructions please refer to the GaGe CompuScope Startup Guide which was shipped with your order Please note if you had MATLAB installed when you installed the CompuScope MATLAB SDK then the required path settings will be automatically updated upon installation of the SDK If however if you did not have MATLAB installed when you installed the CompuScope MATLAB SDK then you must update the MATLAB path settings manually after installation of MATLAB To do this append AddPath m to Startup m in the MATLAB directory If Startup m does not exist copy AddPath m into the MATLAB directory and change the filename to Startup m AddPath m is installed within the Main MATLAB folder of the MATLAB SDK CompuScope SDK for MATLAB for Windows 5 Chapter 2 Overview of CompuScope MATLAB SDK Structure of CompuScope MATLAB SDK The overall structure of the CompuScope MATLAB SDK and its relation to the GaGe CompuScope Hardware is best described from the bottom up with reference to the diagram below Main MATLAB
33. sary to modify CsMI M file code so that the CsMI M files become the building blocks from which users may construct any required MATLAB M files for their application The Main M files are top level application M files that can be executed directly under MATLAB Each Main MATLAB M file illustrates usage of the CompuScope hardware in different operating modes Main M files are constructed using calls to CsMI M files Users should not attempt to call CsMI M files directly from the MATLAB command line since these M files must be called in the correct order in some cases The Main MATLAB M files are intended as convenient starting points for CompuScope users to develop their own MATLAB applications CompuScope Systems A CompuScope system is defined as a single CompuScope digitizer board or a group of CompuScope boards configured as a Master Slave CompuScope system A Master Slave CompuScope system samples and triggers simultaneously on all channels and is considered to be one multi channel CompuScope system For instance a Master Slave system composed of four CompuScope two channel boards will be considered as a single CompuScope system with eight available input channels By structuring the drivers to consider CompuScope systems a single PC can be equipped with almost any imaginable combinations of CompuScope hardware For instance a PC could be equipped with two separate Master Slave systems of four channels each and then an additional single CompuS
34. se to separate the code that controls each CompuScope system so that acquisitions are performed sequentially on each system Alternately the user may choose to do a deep memory acquisition on one system and a Multiple Record acquisition on another This is done by appropriately merging GageMultipleRecord m and GageDeepAcauisition m using separate CompuScope handles for the two code sections DisplayData m DisplayData m reads CompuScope data from an ASCII DAT file and plots them ina MATLAB plot window The M file may be called from within another M file ReadMrDataFiles m ReadMrDataFiles m reads CompuScope data from an ASCII DAT file created from a Multiple Record acquisition and plots them in a MATLAB mesh plot The M file may be called from within another M file Digital Input CompuScope cards All MATLAB SDK programs may be used to perform acquisitions from digital input CompuScope cards such as the CS3200 and CS3200C Parameters specific to digital input cards may be set by using the CsMI_ConfigureXxx M files with the appropriate CompuScope SDK for MATLAB for Windows 15 modifiers By using these special parameter settings for the digital input CompuScope cards a user may operate any one of the Main M files The CS3200 and CS3200C allow three digital input sample width modes for optimal memory usage 8 bit 16 bit and 32 bit These modes may be selected acg Mode together with the CsMI_Translate m within Setup m and using the following strin
35. t meets the requirement All Main M files should always be executed in their entirety in order to correctly free CompuScope handles so that other processes will be unable to use them Locked handles may be freed from MATLAB however by invoking the CsMI_FreeSystem handle command if the handle value is known or by calling CsMI_FreeAllSystems which will abort all CompuScope operations and free all CompuScope system handles Finally locked handles may be freed from outside of MATLAB by doing a Refresh from the CompuScope Manager utility after exiting MATLAB Overview of CompuScope CsMI M files All Main M CompuScope example files are constructed from CsMI M files which are easy to use building blocks that wrap function calls to the intermediate CsMI dll A MATLAB user is able to develop a custom MATLAB M file for their requirement using only the CsMI M files with no modifications to them All CsMI M files are documented later in this manual All CsMI M files have names of the form CsMI_Xxx m where xxx describes the functionality The M files may be called with arguments and return values using the general form return_value1 return_value2 CSMI_Xxx arg1 arg2 The first argument to the function is usually the handle to the CompuScope system being addressed Generally not all available return values need to be included in the call but will not be assigned unless they are included Some return values however are required
36. to the amount of CompuScope acquisition memory per channel less the amount of post trigger data Newer CompuScope models such as the CS82G CS12400 CS14200 and CS14105 allow for the accumulation of pre trigger data in Multiple Record Mode On these models memory is divided into multiple circular buffers the number of which is equal to the number of records specified The Segment Size control allows the user to specify the size of each circular buffer This way the user may select the amount of memory reserved for pre trigger data accumulation For instance if the user selects a post trigger Depth of 2048 and a Multiple Record Segment Size of 8192 then up to 6144 Samples of pre trigger data may be acquired Increasing the Segment Size beyond the Depth will CompuScope SDK for MATLAB for Windows 20 accordingly reduce the maximum possible number of Multiple Records Only newer CompuScope models such as the CS82G CS12400 CS14200 and CS14105 support pre trigger Multiple Record Mode On older CompuScope models without pre trigger data in Multiple Record Mode the Segment Size setting will have no effect on a Multiple Record acquisition The value is ignored and is forced to be equal to the Depth by the drivers Trigger Holdoff Trigger Holdoff is a feature that is useful for ensuring the accumulation of a specified amount of pre trigger data The Trigger Holdoff setting specifies the amount of time in Samples during which the CompuSc
37. variable may be either a structure or an array of structures MATLAB will handle them either way If chanis a structure it may be referenced as either chan 1 Channel or chan Channel Either way is correct If chan is an array of structures each element contains the structure for channel number i where i begins at 1 chan i Channel The channel number beginning with 1 chan i Coupling The input coupling AC or DC chan i DiffInput A flag that when non zero sets the channel to differential coupling if available chan i InoutRange The channel full scale input range in millivolts For instance set to 2000 for the 1 Volt input range chan i Impedance The channel terminating input impedance in Ohms chan i DcOffset The channel input DC offset in millivolts chan i DirectAdc A flag that when non zero sets the channel to Direct to ADC input coupling if available Trigger Parameters The trig variable may be either a structure or an array of structures MATLAB will handle them either way If trig is a structure it may be referenced as either trig 1 Trigger or trig Trigger Either way is correct If trig is an array of structures each element contains the structure for each trigger engine i where i begins at 1 The use of the trig variable as an array of structures is illustrated within GageComplexTrigger m trig Trigger The trigger engine number beginning with 1 trig Slope The trigger slope Positive or Negative t
38. wo engines can be configured independently and their outputs are Boolean ORed together so that either engine may cause a trigger event For simple triggering the second engine is disabled The trig structure array allows the separate configuration of each trigger engine For instance by setting the two engine sources to Channel 1and Channel 2 the user may configure the system to trigger on a pulse that occurs on either channel Alternately by setting both engine sources to Channel 1 but selecting different levels and slopes for each the user may configure the system to do windowed triggering where the system triggers if the input level leaves a specified voltage range GageComplexTriggerAcquire m uses the trig structure as an array where each element controls a separate trigger engine Otherwise the M file is just like GageAcquire m GageMultipleSystems m GageMultipleSystems m is the Main M file for Multiple Independent CompuScope systems The M file begins by obtaining the number of CompuScope systems within the host PC It then obtains a handle to each of these systems The GageMultipleSystems m then proceeds to execute the same order of operations as GageAcquire m except each operation is within a loop that successively operates on each CompuScope system A user can extend the logic illustrated within GageMultipleSystems m to achieve any acquisition sequence from Multiple Independent CompuScope systems For instance the user may choo
Download Pdf Manuals
Related Search
Related Contents
HD Review Mirror Recorder User manual TAFCO WINDOWS NU2-147S-W Instructions / Assembly StarTech.com USB 3.0 to 4-Bay SATA 6Gbps Hard Drive Docking Station w/ UASP & Dual Fans - 2.5/3.5in SSD / HDD Dock Scytek electronic 5100RS-22W Automobile Alarm User Manual TRS101[03.03] USER`S MANUAL Manual do usuário Epson PowerLite S4 099SVR5 USER MANUAL FR PC10 User Manual 203 KB Copyright © All rights reserved.