1. 2 pair UTP Cat 3 4 5 EIA TIA 568 100 ohm STP 100BASE TX 2 pair UTP Cat 5 EIA TIA 568 100 ohm STP 1 x 10 100BASE TX port Fixed Ports 1 x 9 pin RS232 Console port Consumption Temperature Operating 0 50 C Storage 10 70 C Humidity Operating 10 90 Storage 5 90 FCC Class A CE Mark Class A VCCI Class A Cable 21
2. it needs to reboot the software setting in order to run the device properly 13 2 Factory Reset This function is to set the device back to the default setting in case of the messy setting 1 3 Image Update al192 1608 1 2_ IFIP es Update File Imcimage The section is to set the TFTP Server IP Address first and the default address was set to 192 168 1 2 The Image File can be updated by uploading the image file from the TFTP server Note The content of the image file will write the whole firmware of the management module please be sure that the image file is correct 2 Configuration General Configuration System Configuration Media Converter Chassis Media Converters Status Media Converters Setting Redundant Backup Setting There are four items in the Configuration menu General Configuration System Configuration Media Converter Chassis and Media Converters 2 1 General Configuration Hardware revision A2 BIOS revision 1 01 Firmware revision 1 16 Change Password l Confirm Password I System Location I Refresh T me 5 Hardware revision noted the version of the hardware BIOS revision noted the version of the BIOS Firmware revision noted the version of the firmware Change Password the changing of the admit password Confirm Password to confirm the setting of admit password System Name to authorize the device system name Location to show the device where i
3. will show out the MAC address of the SNMP Management Module IP Address to allocate an IP address for the SNMP Management Module the default IP is 192 168 1 1 Subnet Mask to set the Subnet Mask the default is 255 255 255 0 Default Gateway to set the gateway address the default is 192 168 1 254 NOTE After configuring the system device need to press the save button to save the setting 2 3 SNMP Configuration SHMF Configuration GMAT orte OD MESATARE Ent Din Ass Enable CO Enable O Dinti FAAP Citi C Din MC Pillow Traps Enable Disb M frkenTrap 7 E Enable C Disable OD agi i or emus Sana Get Community Name to get the device community name default public Set Community Name to set the device community name default private Trap Community Name to authorize the device trap community name default public Trap Host IP Address to set the trap host IP address same as monitoring station IP address Cold Start trap to set the trap for rebooting the device default enable Warm Start trap to set the trap when the device had been reset default enable Authentication Fail Trap to set the warning trap when the community name of the device and workstation are different default enable Power Fail Trap to set the Power Fail Tra
4. SNMP Management Module Connecting the SNMP Management Module Tells how you can connect the SNMP Management Module to your network Technical Specifications Lists the technical general physical and environmental performance and Routers settings specifications of the SNMP Management Module UNPACKING AND INSTALL This chapter provides unpacking and setup information for the SNMP Management Module Unpacking Open the box of the Management Module and carefully unpack it The box should contain the following items One SNMP Management Module RS232 Cable 9 pin female to 9 pin female This User s Guide If any item is found missing or damaged please contact your local reseller for replacement Installing the Management Module Install the SNMP Management Module into the Media Converter Chassis Connect the SNMP Management Module to the network The chassis s first slot is for the SNMP Management Module as illustration Slide in the management module in the first slot of the chassis system IDENTIFYING EXTERNAL COMPONENTS This section identifies all the major external components of the SNMP Management Module The front panel is shown followed by a description of each panel feature The indicator panel is described in detail in the next chapter Front Panel The figure below shows the front panels of the SNMP Management Module The LED indicators of the SNMP Management Module include Po
5. ENTS ee eee eee eene 5 FRONTE PANE 5 1 2 0 dsiivasiv E eigene 5 LED INDICATORS Ha einsehen eg 6 CONFIGURING THE SYSTEM cccccccccsccccccccccccccccccees 7 MANAGEMENT THROUGH WEB BROWSER cscececececececececececececeeees 7 CONFIGURE THROUGH TERMINAL EMULATOR TELNET PROGRAM12 MANAGEMENT SETTING THROUGH TERMINAL EMULATOR 13 APPENDIR C Tvr p A 19 INTRODUCTION The SNMP Management Module supports the Media Converter Chassis to monitor the each Media Converter Module status and to configure advanced function of the Media Converter Chassis Through in band management via TELNET Web Browser and SNMP management utility or the out band management via RS 232 console port to monitor configure the Media Converter Chassis The SNMP Management Module supports SNMP protocol to advise the network manager while the device occur an abnormal status Purpose This manual discusses how to install the SNMP Management Module to the Media Converter Chassis Overview of this User s Guide Introduction Describes the SNMP Management Module and its features Unpacking and Install Helps you get started with the basic installation of the SNMP Management Module Identifying External Components Describes the front panel and LED indicators of the SNMP Management Module Configure The Management Module Helps you how to configure the
6. Media Converter Chassis SNMP Management User s Guide FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures VCCI Warning HE ORE FEMS VCC OBS TORE CHEAT SLE RH EEB TILDET DESEE A TABLE OF CONTENTS INTRODUCTION zoraaa 1 PURPOSE etu EEEE esse PESES 1 OVERVIEW OF THIS USER S GUIDE eere eee eere renes 1 UNPACKING AND INSTALL 000000000000000000000000000000000 00000000000 3 dde nara aces UE tet ace ta See DET 3 INSTALLING THE MANAGEMENT MODULE cceccecescecceccecescescecens 3 IDENTIFYING EXTERNAL COMPON
7. e MC Broken trap to set the trap when the Media Converter module was broken default enable MC Link up trap to set the trap when a linking is connected default enable MC Link down trap to set the trap when a linking is disconnected default enable MC Active Slot Xchg trap to set the trap when there is a redundant function activated default enable MC Active Slot Lose trap to set the trap when the redundant function is fail default enable 18 APPENDIX When forgot the password Boot up the chassis system and press the escape button repetitious three to four times then press root for login the BIOS setting some command key as follow will help help Is list sysconf system configuration flash boot Help to check the usage of the command list Ls to list out the command key Sysconf to configure or view the system parameter to IIC EEPROM Flash to flash the image file from TFTP server Boot to boot up the system The usage will indicate out on the screen when the command key was input error 19 TECHNICAL SPECIFICATIONS General IEEE 802 3 10Base T Ethernet Applicable IEEE 802 3u 100 Base TX Fast Ethernet Standards IEEE 802 3x flow control Protocol CSMA CD Data Transfer Ethernet 10Mbps half duplex 20Mbps full duplex Rate Fast Ethernet 100Mbps half duplex 200Mbps full duplex LED Indicators Power On Power Fail Fan Fail MGM Console Link ACT 1OBASET
8. e about network devices device configuration network management and Internet browsers The user is assumed to be a network administrator or manager with an understanding of network operations Management through Web browser The SNMP Media Converter Chassis is accessible using a Web browser IE explorer Netscape Communications etc to open up the chassis monitoring system The default IP Address for the chassis system is 192 168 1 1 and the default Login name and password is both root Main Menu The Main Menu will show out the Hardware Revision BIOS Revision and Firmware Revision to set the management system click on the left side menu System Function and Configuration in the center screen is the status screen that appears where you clicked on the left side menu Click on the Media Converter slot and it will appear a screen for you to monitor or control depend on what media converter you are using System Function ilr wr mis Pe There are four items in System Function menu Software Reboot SENS Factory Reset Image Update and Configuration Update bent arem 1 y 1 2 Software Reboot aips Fre een Reboot the management module in order to run the new setting tt properly IL 1 3 Factory Reset This function is to set the device back to the default setting in case of the messy setting Kr 1 4 Image Update MAS The s
9. e to the slave line in case of the linking fails happen The Redundant functions were set fixed the master slot is slot 1 odd number slot and the slave slot is slot 2 even number slot and there are eight redundant groups in all The Act will indicate what slot is active When the slave slot is active and we need to transfer again to the master slot push on the restart button The redundant function depends only on some Smart Media Converter Modules 17 3 SNMP Configuration Get Community Name to get the device community name default public Set Community Name to set the device community name default private Trap Community Name to authorize the device trap community name default public Trap Host IP Address to set the trap host IP address same as monitoring station IP address Cold Start trap to set the trap for rebooting the device default enable Warm Start trap to set the trap when the device had been reset default 2 enable Authentication Fail Trap to set the warning trap when the community name of the device and workstation are different default enable Power Fail Trap to set the Power Fail Trap default enable Fan Fail Trap to set the fan fail trap default enable MC Plug in Trap to set the trap when a Media Converter module has been plugged in default enable MC Pullout Trap to set the trap when the Media Converter module has been pulled out default enabl
10. ection is to set the TFTP Server IP Address first and the default address was set to 192 168 1 2 The Image File can be updated by uploading the image file from the TFTP server Note The content of the image file will write the whole firmware of the management module please be sure that the image file is correct 1 5 Configuration Update The section is explaining how to upload and download the configure setting of the module The Configuration Upload is to restore a setting file to the management module The Configuration Download is to backup the setting from the management module 2 Configuration There are five items in Configuration menu General Configuration System Configuration SNMP Configuration Location Setting and Redundant Backup Setting 2 1 General Configuration Hardware revision noted the version of the Media Converter Chassis BIOS revision noted the version of the BIOS Firmware revision noted the version of the firmware Change Password the changing of the admit password Confirm Password to confirm the setting of admit password System Name to authorize the device system name Location to show the Media Converter Chassis where it is located Refresh time to set the refreshing time of the device through the web NOTE After configuring the system device need to press the save button to save the setting 2 2 General Configuration DATE MAC Address
11. l and Link Enable the Media 2 LLR function Auto Negotiation Duplex mode and Link Enable The in the screen stands for N A not available and the management module will detect if the slot has the function in it and will let you set the function exist on the media converter slot Select the slot and press the space bar button to choose which function to open up Device Link Loss Carry Forward or off Enable to enable the link of the Device or off 16 Media 1 LLR Link Loss Return or off Auto A for Auto Negotiation or for forced Mode Speed to select the speed of the copper port 10M 100M or 1G Duplex mode for Full Duplex or H for Half Duplex FC Flow Control on or off Enable to enable the link of the Media 1 or off Media 2 LLR Link Loss Return or off Auto A for Auto Negotiation or for forced Mode Duplex mode for Full Duplex or for Half Duplex Enable to enable the link of the Media 1 on or off Some of the function can be control only depends on the Smart Media Converter Modules 2 6 Redundant Backup Setting Group 01 2 Disable 3 Disable UTES h 2 Disable 6 Disab 17 D sable AR Disable The redundant function is to change the master lin
12. only on some Smart Media Converters Configure Through Terminal Emulator TELNET Program Console and Terminal Emulator program setting The SNMP Media Converter Chassis can be accessible using a terminal or terminal emulator attached to the RS232 serial port 1 Locate correct DBO serial port cable with female DB9 connector 2 Attach the DB9 serial port female cable connector to the male DB9 serial port connector on the chassis system 3 Attach the other end of DB9 serial port cable to a remote the workstation 4 By default the Media Converter uses the following serial port parameter values Bits per second 57600 Stop bits 1 Data bits 8 Parity NONE Flow Control NONE The default Login name and password is both roof 12 TELNET program setting The SNMP Media Converter Chassis can be accessible using TELNET through LAN 1 Run TELNET program 2 Enter the IP address 192 168 1 1 the factory default IP address setting 3 The default Login name and password is both root Management Setting Through Terminal Emulator Main Menu There are three items in the Main Menu System Function Configuration and SNMP Configuration system Function Configuration snmp Configuration System Function There are three items in System Function menu Software Reboot Factory Reset Image Update software Reboot actory Reset Update 1 1 Software Reboot After configuring
13. p default enable Fan Fail Trap to set the Fan fail trap default enable MC Plug in Trap to set the trap when a Media Converter Module has been plugged in default enable MC Pullout Trap to set the trap when the Media Converter Module has been pulled out default enable 10 MC Broken trap to set the trap when the Media Converter Module was broken default enable MC Link up trap to set the trap when a linking is connected default enable MC Link down trap to set the trap when a linking is disconnected default enable MC Active Slot Xchg trap to set the trap when there is a redundant function activated default enable MC Active Slot Lose trap to set the trap when the redundant function is fail default enable 2 4 Location Setting Comedies Locke Seeing Allocating each slot s location in order to remember in where each slot was connected 2 5 Redundant Backup Setting Li Li Li Li n n 1 The redundant function is to change the master line to the slave line in case of the linking fails happen The Redundant functions were set fixed the master slot is slot 1 odd number slot and the slave slot is slot 2 even number slot and there are eight redundant groups in all The Act will indicate what slot is active When the slave slot is active and we need to transfer again to the master slot we need to push on the restart button The redundant function depends
14. t is located Refresh time to set the refreshing time of the device through the web 2 2 System Configuration MAC Address 00 480 T4 47 92 53 IP Address BEPMBLT RUN subnet Mask 255 255 255 8 Default GW 192 168 1 254 MAC Address will show out the MAC address of the device IP Address to allocate an IP address for the device the default IP is 192 168 1 1 Subnet Mask to set the Subnet Mask the default is 255 255 255 0 Default Gateway to set the gateway address the default is 192 168 1 254 NOTE After configuring the system device need to press the save button to save the setting 2 3 Media Converter Chassis Plug n Power Fail Fan Fail Power 1 T w x Power 2 T The screen will show out the power status of the chassis system V stands for yes and X stands for No Plug in indicates if Power 1 or 2 was plugged in or not Power Fail indicates if the Power 1 or 2 is fail or not Fan Fail indicates if the Fan 1 or 2 is fail or not 15 2 4 Media Converters Lone amgur at loi i Reed i Mi J r m un T Plugin i I 1 i ik Titel 1 La 1 TM E Indicates the Link Duplex mode Speed and Fail status of each media converter 2 5 Media Converters Setting This screen is to set the Device function of LLCF and Link Enable the Media 1 LLR function Auto Negotiation Speed Duplex Mode Flow Contro
15. wer On Power Fail Fan Fail MGM Console and Link ACT The following shows the LED indicators for the Switch along with an explanation of each indicator LED Indicator Panel T a Refer to the next section for detailed Lone Copper information LED ol Port gt Console Port RS232 Indicator To configure the device through E Terminal Emulation Program via s RS232 serial port 10 100BASE TX Twisted Pair Port To configure the device through Web Browser or TELNET program via LAN Ethernet Console Port CONSOLE t DATATRANSFER 3 ERRORDATA LINK ACT LINK AX DATATRANSFER LED Indicators There are two powers at the rear and will indicates on the front panel the status of the power and fan Power On Lights green when the power is inserted Power Fail Lights Amber when the power is inserted and it is fail Fan Fail Lights Amber when the fan is fail to work MGM Blinks green when the device CPU is working and lights amber when the CPU works fail Console Blinks green when the data is transmitting through console port and blinks amber when transmitting the wrong data Link Act Lights green when link to networking Ethernet and blinks green for activity CONFIGURING THE SYSTEM This chapter provides network managers and system administrators with information about how to configure the Media Converter Chassis via the SNMP Management Module The reader of this document should be knowledgeabl