Contents

1. 1 1 3 11 Connection with Screen Blanking SK SK SK KK KK KK KK KK KK KK R 3 12 Connection with Relay Mechanical Switch for Screen Blanking 3 13 Connect Multipurpose Cable 2 2 1 2212 1 1 1 3 14 Chapter 4 Product Agency Compliance ThorVX9 000827 4 1 Lithium Battery Safety Statement ooo ocn 4 3 Vehicle Power Supply Connection Safety Statement 4 5 Chapter 5 Technical Assistance XU 0870714 5 1 Chapter 1 Introduction The Thor VX9 is also known as the The Thor VX9 Vehicle Mount Computer VMT is a rugged vehicle mounted PC Personal Computer equipped with a Microsoft Windows operating system The Thor VX9 is capable of wireless data communications from a fork lift truck or any properly configured vehicle The unit uses a PCMCIA radio spread spectrum 2 4GHz for wireless data communications The Thor VXS is a tablet style computer and features a color display The touch screen display supports graphic features and Microsoft Windows icons that the installed Windows operating system supports An illuminated keyboard is available to facilitate use in dimly lit areas The Thor VX9 provides the power and functionality of a desktop computer in a vehicle mounted unit with a wide r
2. Category view Speaker Volume Use the Windows interface to control speaker volume Tap the speaker icon displayed in the task bar or tap Start gt Control Panel gt Hardware and Sound gt Sound Category view Start gt Control Panel gt Sound Classic view Start gt Control Panel gt Sound and Audio Devices gt Sounds Classic view or tap OK Start gt Control Panel gt Sounds Speech and Audio Devices gt Adjust the System Volume Category view Connect Bluetooth Devices Use the Windows interface to manage Bluetooth devices Tap the Bluetooth icon on the Desktop Start gt Control Panel gt Printers and Other Hardware gt Bluetooth Devices Category view Start gt Control Panel gt Bluetooth Devices Classic view or tap 2 3 Restart Shutdown Use the Windows interface to restart or shut down the Thor VX9 Start gt Shut down right arrow list menu gt Restart Start gt Shut down o Start gt Shut down gt Restart Start gt Shut down gt Shut down Soft Keyboard The optional soft keyboard can be enabled and configured from the keyboard control panel in the MountFocus software Tap Start gt Programs gt MountFocus POS gt Keyboard Control Panel Calibrate Touch Screen To calibrate the touch screen access the touch screen software Select Tap Start gt Programs gt UPDD gt Calibrate and touch the center of the cross displayed on screen and release Repeat as
3. 2 1 SU E IS 2 1 Tapping the Touch Screen with a Stylus a as a aS SE SEK SK SK SK KK KK KAK KK SK KK KK KK KK KK KK R 2 2 Thor VX9 Configuration Options 2 3 Date and H HHHH HH TW x 2 3 Power 2 3 Speaker Volume 2 3 Connect Bluetooth DEVICES ss gasa hn yna aa ltd ea d k de d e Za 2 3 Restart ShutdoWn 2 4 Soft Keyboard 2 4 Calibrate Touch Screen 2 4 Setup Terminal Emulation Parameters asas saa aa aS a SS SS KK SK SK KK SS KK KK SK KK KK KK K6 2 5 Cleaning the Touch 2 6 Apply the Touch Screen Protective 2 6 Chapter 3 Connecting Cables to the Thor VX9 3 1 Connect 3 1 95 key Rugged Keyboard SH HHHHHHHDDDHHHHHHHHHRDRDRRRRRR mm 3 2 60 key Rugged 3 3 Connect USB DEVICES ps ka dana ii da e ee EE 3 4 Connect Ethernet Cable 3 4 Connect Serial Bar Code Scanner 3 5 External AC Power Supply Optional l lll l l l l l l l 3 6 Connect External Headset o nn 3 7 Connecting Vehicle Power 3 8 Specifications for electrical supply 3 8 Connect Vehicle Electrical Connection l ilili i 3 9 Connection without Screen Blanking
4. Converter O F Power ow wun al r w o ol z Output Input O Attach the stripped wire ends to the output side of the DC to DC converter Attach stripped wire ends to the input side of the DC to DC converter The input block has one Vi and one Vi connection to connect the matching polarity wire The output block has two Vo and two Vo connectors Either connector in the block can be used to connect the match ing polarity wire Use wire ties to secure all wiring providing strain relief for the power supply connections 6 10 11 3 10 If the screen blanking box is used for the Thor VX9 installation attach the stripped wire ends to the box Refer to the applicable following diagram and the label on the screen blanking box for proper wiring connection Connect the DC to DC converter to the vehicle s electrical system While observing the fuse requirements specified above connect the power cable as close as possible to the actual bat tery terminals of the vehicle When available always connect to unswitched terminals in vehicle fuse panel after pro viding proper fusing ATTENTION For uninterrupted power electrical supply connections should not be made at any point after the ignition switch of the vehicle If used connect the wiring for the screen blanking box Use proper electrical and mechanical fastening means for terminating the cable Properly sized crimp type electrical ter
5. an input output device connected to a serial port A right click is generated by tapping the mouse icon in the system tray After tapping the mouse icon highlights the right button of the icon in red The next touch screen tap is treated as a right click The mouse icon returns to the left button highlighted in red so subsequent taps are treated as left clicks A stylus replacement kit is available Thor VX9 Configuration Options Many configuration options are available via the Microsoft Windows Control panel Refer to the Thor VX9 Reference Guide or For Help and Support on the Start menu for configuration details Date and Time Use the Windows interface to set date time and time zone Tap the time displayed in the task bar or tap ER Start gt Control Panel gt Clock Language and Region gt Date and Time Category view Start gt Control Panel gt Date and Time Classic view Start gt Control Panel gt Date and Time Classic view OK Start gt Control Panel gt Date Time Language and Regional Options gt Change the Date and Time Cat egory view Power Management Use the Windows interface to set power management options Start gt Control Panel gt Hardware and Sound gt Power Options Category view Start gt Control Panel gt Power Options Classic view OS Start gt Control Panel gt Power Options Classic view or tap Start gt Control Panel gt Performance and Maintenance gt Power Options
6. minals are an accepted method of termination Please select electrical connectors sized for use with 18AWG 1mm2 con ductors Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals taking care not to over tighten and pinch conductors or penetrate outer cable jacket Connection without Screen Blanking Power Cable Routing without Screen Blanking Za a a 9 O ON D mF ob Existing circuitry on vehicle Forklift Battery Main Switch 10A slow fuse close to power source Power input Isolated DC power output White Brown Yellow Green Vehicle mounted computer Circular power connector Supplied power cable shielding to be trimmed 3 11 Connection with Screen Blanking Box It is assumed that the motion sensing circuitry in the illustration below is powered by internal vehicle circuitry Power Cable Routing with Screen Blanking Box 1 Existing Circuitry on Vehicle 2 Forklift Battery 3 Main Switch 4 10A slow fuse close to power source 5 Power Input 6 Isolated DC power output 7 White 8 Brown 9 Yellow 10 Green 11 Vehicle mounted computer 12 Circular power connector 13 Screen blanking box 14 3A fuse 15 Motion circuitry The voltage at the Vi input on the Screen Blanking Box must be between 10VDC and 60 or 72VDC see Screen Blanking Box label when the vehicle is in motion and le
7. optional screen blank Output Volt 12VDC 10 models VX89301PVVRSPLY VX89A302PSDC48V VX89303PWPSPLY age 13 2VDC 10 models VX89305PWRSPLY VX89306PWRSPLY A 60 W models VX89301PVVRSPLY VX89302PSDC48V VX89303PWPSPLY 75W models VX89305PWRSPLY VX89306PWRSPLY 10 A slow blow fuse Fuse 3 A for optional screen blanking box Fuses are USER SUPPLIED Please refer to the appropriate wiring schematic below for wiring colors and connections For proper and safe installation the input power cable must be connected to a fused circuit on the vehicle This fused circuit requires a user supplied 10 Amp maximum time delay slow blow high interrupting rating fuse If the supply connection is made directly to the battery the fuse should be installed in the positive lead within 5 inches of the battery positive terminal The VX power supplies listed above are sealed per IPXX Usage in areas where moisture can affect the power supply connections should be avoided The power supply should be mounted in a dry location within the vehicle or placed in a suitable protective enclosure For installation by trained service personnel only Risk of ignition or explosion Explosive gas mixture may be vented from battery Work only in well ventilated area Avoid creating arcs and sparks at battery terminals 3 8 Connect Vehicle Electrical Connection 5a 5b Please review the proper wiring schematic illustration later in this sect
8. the cross is displayed in various locations The utility closes automatically upon calibration completion 2 4 Setup Terminal Emulation Parameters Before you make a host connection you will at a minimum need to know 1 the alias name or IP address Host Address and the port number Telnet Port of the host system to properly set up your host session Make sure the mobile client network settings are configured and functional If you are connecting over wireless LAN 802 11x make sure your mobile client is communicating with the Access Point From Start gt Program run RFTerm or tap the RFTerm icon on the desktop Select Session gt Configure from the application menu and select the host type that you require This will depend on the type of host system that you are going to connect to i e 3270 mainframe AS 400 5250 server or VT host Enter the Host Address of the host system that you wish to connect to This may either be a DNS name or an IP address of the host system Update the telnet port number if your host application is configured to listen on a specific port If not just use the default telnet port Select OK Select Session gt Connect from the application menu or tap the Connect button on the Tool Bar Upon a successful connection you should see the host application screen displayed To change options such as Display Colors Cursor Bar Code etc please refer to these sections in the RFTerm Re
9. Greek GR Italian IT Norwegian NO Portuguese PT Spanish ES Svvedish SE Turkish TR 4 5 4 6 Chapter 5 Technical Assistance If you need assistance installing or troubleshooting your device please contact us by using one of the methods below Knowledge Base www hsmknowledgebase com Our Knowledge Base provides thousands of immediate solutions If the Knowledge Base cannot help our Technical Support Portal see below provides an easy way to report your problem or ask your question Technical Support Portal www hsmsupportportal com The Technical Support Portal not only allows you to report your problem but it also provides immediate solutions to your technical issues by searching our Knowledge Base With the Portal you can submit and track your questions online and send and receive attachments Web form www hsmcontactsupport com You can contact our technical support team directly by filling out our online support form Enter your contact details and the description of the question problem Telephone www honeywellaidc com locations For our latest contact information please check our website at the link above Product Service and Repair Honeywell International Inc provides service for all of its products through service centers throughout the world To obtain warranty or non warranty service please visit www honeywellaidc com and select Support gt Contact Service and Repair to see your regio
10. Power Supply Connection If the supply connection is made directly to the battery a 10A slow blow fuse should be installed in the positive lead within 5 inches 12 7 cm of the battery positive terminal US Raccordement de Palimentation du v hicule Si l alimentation est raccord e directement a la batterie un fusible a action retard e de 10A doit tre install sur le cable positif a moins de 12 7 cm de la borne positive de la batterie FR EL forsyning af kgretajet Er forsyningsforbindelsen direkte tilknyttet til batteriet og og tilsluttet til den positive part indenfor 12 7 cm delen vil der v re en langsom teendelse af 10 ampere DK Kytkenta ajoneuvon virtalahteeseen Jos virtaa otetaan suoraan akusta 10 ampeerin hidas sulake on asennettava positiiviseen johtoon enint n 12 cm n et isyydelle akun positiivisesta navasta Fl Anschluss an Fahrzeugbatterie Bei direktem Anschluss an die Fahrzeugbatterie sollte eine tr ge 10A Sicherung in die positive Leitung zwischengeschaltet werden und zwar nicht weiter als ca 13 cm von der positiven Batterieklemme entfemt DE Z v son lox o Av n c v son TOU Vivel kateuBeiav OTN HTTOTOD O pra Bpadeiag TENG rv 10A Ba va TOTTOBETNBE oro BeTIK KAAWOIO VT 5 IvTOWV 12 7 EK TOU BETIKOU TNS uTraTopio GR Collegamento dell alimentazione
11. The battery should be disposed of properly The battery should not be disassembled or crushed The battery should not be heated above 212 F 100 C or incinerated RF Safety Notice This device is intended to transmit RF energy For protection against RF exposure to humans and in accordance A with FCC rules and Industry Canada rules this transmitter should be installed such that a minimum separation dis tance of at least 20 cm 7 8 in is maintained between the antenna and the general population This device is not to be co located with other transmitters Bluetooth and GSM technology are not available in Brazil Bluetooth e tecnologia GSM nao est o disponiveis no Brasil Waste Electrical and Electronic Equipment WEEE Important E This symbol is placed on the product to remind users to dispose of Waste Electrical and Electronic Equipment WEEE appropriately per Directive 2002 96 EC In most areas this product can be recycled reclaimed and re nn used when properly discarded Do not discard labeled units with trash For information about proper disposal visit www honeywellaidc com Dealer License Republic of Singapore 0 with Republic of Si LXE Dealer Li Number DA103458 li ith IDA IDA Standards 7 ngapore ealer License Number 58 complies vvit DA103458 4 2 Lithium Battery Safety Statement Caution Lithium battery inside Danger of explosion if battery is incorrectly replaced Replace only with same or equival
12. Thor VX9 Vehicle Mount Computer Microsoft Windows Embedded Standard Operating System Microsoft Windows 7 Professional Operating System Microsoft Windows XP Professional Operating System User s Guide Honeywell Disclaimer Honeywell International Inc HII reserves the right to make changes in specifications and other information contained in this document without prior notice and the reader should in all cases consult HII to determine whether any such changes have been made The information in this publication does not represent a commitment on the part of HII HII shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII 2009 2013 Honeywell International Inc All rights reserved Web Address www honeywellaidc com RFTerm is a trademark or registered trademark of EMS Technologies Inc in the United States and or other countries Microsoft Windows ActiveSync MSN Outlook Windows Mobile the Windows logo and Windows Media are registered trademarks or trademarks of Microsoft Corporation Intel Atom Core Celeron a
13. al secondary keys These keys are identified by the superscripted text found on the keyboard keys The secondary keys are accessible by using two 2 keystrokes the 2nd key followed by the superscripted key Once the 2 state is enabled by pressing the 21d key the Secondary Mode LED is illuminated and the 29 state is enabled until another key is pressed The 29 key is toggled on with a 2 4 keypress and then immediately off with another 2 d keypress Keyboard Backlight The keyboard keys are backlit with LEDs The backlight is manually controlled using the 21d CTRL F10 keypress sequence 95 Key Keyboard with Pointing Device Designed for ease of use with Windows operating systems the 95 key QWERTY keyboard with pointing device connects via a cable to the keyboard port on the Thor VX9 Additional Windows keys the Windows logo key and the Application key and an integrated pointing device are provided for ease of use with Windows operating systems 82 2 2 2 2 fJ 2 EJ 2 2 ls 5 t3 2 D L J kb ID E E E E 64 2 5 25 55 55 GTRIEIEIEURIRIEIKIUUUIS7IRIIRK iz 2 12 2 4 2 22 JOBE 5 The 95 keyboard supports all 104 keyboard functions 101 keyboard standard plus Windows keys and includes an integrated pointing device and left and right mouse buttons However because the keyboard only has 95 keys all functions are not visible or printed on the keyboard Ple
14. and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notice Changes or modifications made to this equipment not expressly approved by Honeywell may void the FCC authorization to operate this equipment Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Le present appareil num rique n emet pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de Classe A prescrites dans le R glement sur le brouillage radio lectrique edits par le ministere des Communications du Canada EMC Directive Requirements This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Li lon Battery When disposing of the Thor VX9 main battery the following precautions should be observed
15. ange of options The Thor VXS is available with the following operating systems Windows 7 Professional 6 Windows Embedded Standard Windows XP Embedded Professional The Thor VX9 can support only one operating system at a time Information in this guide includes instruction for all operating systems About this Guide This Thor VX9 User s Guide provides instruction for the end user or system administrator to follow when setting up a new Thor VX9 Microsoft VVindovvs License Agreement First Boot If your Thor VX9 is shipped with a Microsoft Windows operating system pre installed it may be necessary to com plete the Windows licensing registration screens when starting the Thor VX9 for the first time To complete this information you may need the Microsoft Windows software product key that was included with the Thor VX9 1 1 Components Bottom View rb 0 Multipurpose Connection provides USB COM4 with optional 12V on pin 9 or both with optional cables 9 Audio Out 3 5mm Mic In 3 5 mm LED Indicators Power Button Screen Brightness Controls Decrease Screen Brightness Increase Screen Brightness PowerLED CE Ha eC jp q 4 UPS Mode LED ssr Ze COM1 PowerLED COM2 Power LED Under Service Lid 1 Torx 20 Screws 2 PCMCIA Card Slots optional 3 PCMCIA Card Ejection Buttons 1 4 Power LED The Power LED is locate
16. ase refer to the Key Maps section of the Thor VX9 Reference Guide NumLock For the 95 key keyboard the NumLock key and the numeric keys are backlit green when NumLock is off When NumLock is on the backlight for the NumLock key and the numeric keys is amber CapsLock and Scroll Lock For the 95 key keyboard the CapsLock key is backlit green when CapsLock is off When CapsLock is on the backlight for the CapsLock key is amber The Scroll Lock key is backlit green when Scroll Lock is off When Scroll Lock is on the backlight for the Scroll Lock key is amber The default values for CapsLock and Scroll Lock are Off Keyboard Backlight The 95 key keyboard backlights each key with an LED The keyboard backlight is manually controlled using the backlight key in the upper right hand corner of the keyboard Pressing the backlight key cycles the keyboard backlight through the levels of backlight intensity e Off e Maximum intensity e Medium intensity e Low intensity 1 8 Chapter 2 Set Up A New Thor VX9 This page lists a quick outline of the steps you might take when setting up a new Thor VX9 More instruction for each step is listed later in this guide Please refer to the Thor VX9 Reference Guide for additional information and instruction Contact Technical Assistance if you need additional help Note Installing or removing accessories should be performed on a clean well lit surface When necessary protect the wor
17. ate and severable which means that if any provision is held invalid and unenforceable such determination shall not affect the validity of enforceability of the other provisions hereof Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty This includes but is not limited to cables power supplies cradles and docking stations HII extends these warranties only to the first end users of the products These warranties are non transferable The duration of the limited warranty for the Thor VX9 is 1 year The duration of the limited warranty for the Thor VX9 Vehicle Mount Assembly is 1 year The duration of the limited warranty for the Thor VX9 internal UPS battery is 1 year The duration of the limited warranty for the Thor VX9 AC power supply and cables is 1 year The duration of the limited warranty for the Thor VX9 DC DC Converter is 1 year The duration of the limited warranty for the Thor VX9 cables USB Serial Communication Power is 1 year 5 2 5 3 Honeywell Scanning amp Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com E EQ VX9OGVVVV Rev K 2 13
18. ceived with the bar code scanner for complete instructions 3 5 External AC Power Supply Optional 3 6 BO N a Cf ka m ca Turn the Thor VX9 off Connect the appropriate detachable cordset to the external power supply Plug cordset into appropriate grounded electrical supply receptacle AC mains Connect the watertight connector end to the Thor VX9 s Power Connector by aligning the connector pins to the power connector push down on the watertight connector and twist it to fasten securely Turn the Thor VX9 on Connect External Headset The Thor VX9 provides an external headset connection via an audio jack connector and a microphone to a separate microphone jack connector The connectors are color keyed and marked with the headset and microphone symbols TT 20 oO k A 1 Insert the speaker or headphone plug into the audio connector making sure the plug is firmly seated in the jack 2 Insert the microphone plug into the microphone connector making sure the plug is firmly seated in the jack 3 7 Connecting Vehicle Power 9 Dn oo VU 7 Complete vehicle cradle mounting and power instruction is contained in the Thor VX9 Cradle Guide The DC to DC converter is used to power the Thor VX9 The converter must be used with the Thor VX9 regardless of vehicle voltage Specifications for electrical supply Input Voltage 5 observe input voltage range specified on the DC to DC power supply and the
19. d are the property of their respective owners Patents For patent information please refer to www honeywellaidc com patents Limited Warranty Refer to www honeywellaidc com warranty_ information for your product s warranty information Table of Contents Chapter 1 Introduction 0014 _ 11 About this Guide 0010010101 HH 7707777777 P 7 1 1 Microsoft Windows License Agreement First Boot 1 1 elle TN EE 1 2 Bottom EV 000 9 HHH s HHH 1 2 LED Indicators a aaa a n mal as lala aaa s 1 3 Under Service Lido HNH E 1 4 1 1 5 UPS Mode A pbpTcDp__ __ RHRHHHHH gg 15 COM Port LEDS 15 60 Key Keyboard ll l 1 6 AAA 1 6 1 6 AA AA 1 6 Secondary HHHH HHHH 1 6 Keyboard Backlight aa aa dee b dlhl la kad id S z a h Sad BAD bb abe hd bea does 1 6 95 Key Keyboard with Pointing 1 7 QALE SH HHHH HHHH 1 7 INTEC EE 1 7 CapsLock and Scroll Lock 1 22 111 1 1 222 2 1 1 11 1 7 Keyboard Backlight l l lll ll l ll l l l l 1 8 Chapter 2 Set Up ANewThorVX9_ 80 2 1 Hardware SU 7
20. d beside the power button UPS Mode LED The UPS Mode LED is located between the brightness control buttons COM Port LEDs There is an LED next to both the COM1 and COM2 serial ports COM Port LED behavior COM Port State Off dark No power applied to COM port 5V power is applied to pin 9 of COM1 12V power is applied to pin 9 of COM2 60 Key Keyboard The 60 key QWERTY keyboard has 101 keyboard functions including a numeric keyboard pad The 60 key keyboard is also available with overlays designed fro use with IBM 3270 and IBM 5250 terminal emulations cosa ets HU TL Y BKSP 5 6 OOG G G G 666 t 0608000096068089 98 f 0 Key Maps The 60 key keyboard supports all 101 keyboard functions However because the keyboard only has 60 keys all functions are not visible or printed on the keyboard Please refer to the Key Maps section of the Thor VX9 Reference Guide NumLock The 60 key keyboard does not have a NumLock indicator or key NumLock be toggled On or Off using the 21d SHIFT F10 keypress sequence Changes made to the NumLock status persist across a Windows restart CapsLock The CAPs LED indicates the state of the keyboard CapsLock mode If CapsLock is enabled this LED is illuminated green When CapsLock is off the LED is dark Press 2 then F1 to toggle CapsLock On and Off The default value of CapsLock is Off Secondary Keys The VMT keyboard is equipped with sever
21. del veicolo Se il collegamento dell alimentazione viene stabilito direttamente con la batteria necessario installare un fusibile ad azione lenta da 10A nel conduttore positivo a meno di 5 in 12 7 cm dal terminale positivo della batteria IT Tilkople str mforsyningen til kj ret yet Hvis str mforsyningen koples direkte til batteriet skal det installeres en 10A treg sikring i den positive ledningen innen 12 7 cm fra plusspolen p batteriet NO Liga ao do fomecimento de corrente do veiculo Se a liga ao de fomecimento de corrente for ligada directamente a bateria deve instalar se um fusivel de 10A no terminal positivo a 12 7 cm do terminal positivo da bateria PT Conexi n de suministro el ctrico para el veh culo Si el suministro el ctrico se proporciona directamente a la bater a se debe instalar un fusible de retardo de 10A en el conductor positivo como m ximo a 12 7 cm 5 pulgadas del terminal positivo ES Fordonets str mf rs riningskoppling Om str mkopplingen g rs direkt till batteriet m ste en 10A s kring installeras i den positivt laddade ledningen inom 12 7 cm fr n batteriets pluspol SE Ta t G Kayna Ba lant s Kaynak ba lant s do rudan ak ye yap l rsa pozitif ba lant kablosu zerinde ak n n pozitif kutbuna 12 7 cm mesafede 10ATlk yava atan bir sigorta monte edilmelidir TR Legend Danish DK English US Finnish Fl French FR German DE
22. dges are trapped between the protective film and the glass display remove the protective film clean the display and apply the protective film again Contact Technical Assistance about protective film packs designed specifically for your Thor VX9 touch screen Chapter 3 Connecting Cables to the Thor VX9 Connect Keyboard The Thor VX9 has a D9 connector for the keyboard and mouse 1 K it E ZS 1 Connect the adapter cable to the keyboard connector on the Thor VX9 2 Connect the keyboard to the adapter cable 3 1 95 key Rugged Keyboard The 95 key keyboard contains an integrated 2 button mouse shown with adapter cable 1 To adapter cable 2 To 95 key keyboard cable 3 To VX9 keyboard connector 60 key Rugged Keyboard Shown with adapter cable O HAHHA OC HOO HO00 2 9 1 To adapter cable 2 To 60 key keyboard cable 3 To VX9 keyboard connector 6889989 85e68959 87 06 6 3 3 Connect USB Devices The Thor VX9 provides the following Type A ports e external USB port see below e a USB port via a dongle cable attached to the multipurpose port Plug the desired device such as a USB mouse or storage device into the USB port Refer to Start gt Help and Support and the documentation for your USB device for more information USB devices may be installed removed or swapped without turning off the Thor VX9 Connect Etherne
23. ent type recommended by battery manufacturer US Attention Contient une pile de lithium Risque d explosion dans le cas ou la pile ne serait pas correctement remplac e Remplacer uniquement avec une pile semblable ou equivalente au type de pile recommande par le fabricant FR Forsigtig Indeholder lithiumbattterier Risiko for eksplosion hvis batteriet udskiftes forkert Ma kun udskiftes med samme eller tilsvarende type som anbefalet af fabikanten DK Varoitus Tama tuote kayttaa laservaloa Skannerissa on jokin seuraavista tarroista Lue Huomio kohta Fl Vorsicht Enth lt Lithium Batterie Bei unsachgemafsem Ersatz besteht Explosionsgefahr Nur durch gleichen oder vom Hersteller empfohlenen Typ ersetzen DE Attenzione Batteria al litio Pericolo di esplosione qualora la batteria venga sostituita in maniera scorretta Sostituire solo con lo stesso tipo o equivalente consigliato per il fabbricante IT Aten o Cont m pilha de l tio Ha perigo de explos o no caso de uma substitui o incorreta Substitua somente pelo mesmo tipo ou equivalente recomendado pelo fabricante PT Varning Inneh ller litiumbatteri Fara for explosion om batteriet ar felaktigt placerat eller av fel typ Anvand endast samma eller motsvarande typ batterier rekommenderade av tillverkaren SE Advarsel Innmontert Lithium batteri Eksplosjonsfare ved feil montering av batteri Benytt kun batteri anbefalt av produsent NO Cuidado Pila de li
24. ference Guide for complete descriptions of these and other features 2 5 Cleaning the Touch Screen Note These instructions are for components made of glass If there is a removable protective film sheet on the display remove the film sheet before cleaning the screen Keep fingers and rough or sharp objects away from the bar code reader scanning aperture and the mobile device touch screen If the glass becomes soiled or smudged clean only with a standard household cleaner such as Windex without vinegar or use Isopropyl Alcohol Dampen the cloth with the cleaner and then wipe the surface Do not use paper towels or harsh chemical based cleaning fluids since they may result in damage to the glass surface Usea clean damp lint free cloth Do not scrub optical surfaces If possible clean only those areas which are soiled Lint and particulates can be removed with clean filtered canned air Apply the Touch Screen Protective Film First clean the touch screen of fingerprints lint particles dust and smudges Remove the protective film from its container Remove any protective backing from the film sheet by lifting the backing from a corner of the film Discard the backing Apply the film to the touch screen starting at one side and smoothing it across the display If air bubbles appear raise the film slightly and continue smoothing the film across the display until it covers the glass surface of the display If dust lint or smu
25. ion before beginning power cable install The computer must be powered off Begin by connecting the power cable to the Thor VX9 Work from this connection with the last connection being to the vehicle s power source Route the cable from the Thor VX9 to the DC to DC converter and optionally the screen blanking box Cut the cable to length and strip the wire ends If the screen blanking box is not used do not strip the green and yellow wires Route the power cable the shortest way possible The cable is rated for a maximum temperature of 105 C 221 F When routing this cable it should be protected from physical damage and from surfaces that might exceed this temperature Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate Always route the cable so that it does not interfere with safe operation and maintenance of the vehicle For models VX89301PWRSPLY VX89A302PSDC48V VX89303PWPSPLY only DC to DC Converter Remove the lid from the DC to DC converter Attach the stripped wire ends to the output side of the DC to DC converter Attach stripped wire ends to the input side of the DC to DC converter The input and output blocks each have two and two minus connectors Either connector in the block can be used to connect the matching polarity wire Use the looms and wire ties to secure all wiring then reattach the cover with the screws For models VX89305PWRSPLY VX89306PWRSPLY only DC to DC
26. k surface the Thor VX9 and components from electrostatic discharge Hardware Setup 1 Connect accessories 2 Connect power cable 3 4 Secure all cables to the Thor VX9 with the Strain Relief Cable Clamps Press the Power key Software Setup Hardware setup should be completed before beginning software setup 1 9 nur n Adiust date and time Setup povver management Adiust speaker volume Connect Bluetooth devices Save settings vvith Restart Enable the Soft Keyboard 2 1 Tapping the Touch Screen with a Stylus Note Always use the point of the stylus for tapping or making strokes on the touch screen Never use an actual pen pencil or sharp abrasive object to write on the touch screen Hold the stylus as if it were a pen or pencil Touch an element on the screen with the tip of the stylus then remove the stylus from the screen Firmly press the stylus into the stylus holder when the stylus is not in use Using a stylus is similar to moving the mouse pointer then left clicking icons on a desktop computer screen Using the stylus to tap icons on the touch screen is the basic action that can O Open applications Choose menu commands Select options in dialog boxes or drop down boxes Drag the slider in a scroll bar Select text by dragging the stylus across the text Place the cursor in a text box prior to typing in data Place the cursor in a text box prior to retrieving data using a scanner imager or
27. n s instructions on how to obtain a Return Material Authorization number RMA You should do this prior to returning the product Limited Warranty Honeywell International Inc HII warrants its products to be free from defects in materials and workmanship and to conform to HII s published specifications applicable to the products purchased at the time of shipment This warranty does not cover any HII product which is i improperly installed or used ii damaged by accident or negligence including failure to follow the proper maintenance service and cleaning schedule or iii damaged as a result of A modification or alteration by the purchaser or other party B excessive voltage or current supplied to or drawn from the interface connections C static electricity or electro static discharge D operation under conditions beyond the specified operating parameters or E repair or service of the product by anyone other than HII or its authorized representatives This warranty shall extend from the time of shipment for the duration published by HII for the product at the time of purchase Warranty Period Any defective product must be returned at purchaser s expense during the Warranty Period to HII factory or authorized service center for inspection No product will be accepted by HII without a Return Materials Authorization which may be obtained by contacting HII In the event that the product is returned to HII or its authorized
28. nd Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Summit Data Communications the Laird Technologies Logo the Summit logo and Connected No Matter What are trademarks of Laird Technologies Inc Atheros and the Atheros logo are registered trademarks of Atheros Communications Inc Broadcom and the Broadcom logo are registered trademarks of Broadcom Corporation The Bluetooth word mark and logos are owned by the Bluetooth SIG Inc Symbol is aregistered trademark of Symbol Technologies MOTOROLA MOTO MOTOROLA SOLUTIONS and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings LLC and are used under license RAM and RAM Mount are both trademarks of National Products Inc 1205 S Orr Street Seattle WA 98108 Freefloat Freefloat Wling and Freefloat Access One are trademarks of Freefloat M lndalsv gen 30B SE 412 63Gothenburg Sweden Verizon is a registered trademark of Verizon Trademark Services LLC T MOBILE is a registered trademark of Deutsche Telekom AG AT amp T is a registered trademark of AT amp T Intellectual Property Option and GlobeTrotter are registered trademarks of Option NV Acrobat Reader 2013 with express permission from Adobe Systems Incorporated Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies an
29. service center within the Warranty Period and HII determines to its satisfaction that the product is defective due to defects in materials or workmanship HII at its sole option will either repair or replace the product without charge except for return shipping to HII EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT HIPS RESPONSIBILITY AND PURCHASER S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS IN NO EVENT 5 1 SHALL HII BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF HII ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT WARRANTY TORT OR OTHERWISE EXCEED THE ACTUAL AMOUNT PAID TO HII FOR THE PRODUCT THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HII MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES LOSSES OR DAMAGES SOME STATES PROVINCES OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU All provisions of this Limited Warranty are separ
30. ss than 5VDC when the vehicle is not in motion 16 Supplied power cable shielding to be trimmed 3 12 Connection with Relay Mechanical Switch for Screen Blanking Power Cable Routing with Screen Blanking Switch Relay xan n n D 2 5 2 5 D D D Existing Circuitry on Vehicle Forklift Battery Main Switch 10A slow fuse close to power source Power Input Isolated DC power output White Brown O MANOA Bb WON a Yellow O Green Vehicle mounted computer N Circular power connector Supplied power cable shielding to be trimmed gt Relay switch that supplies a mechanical electrically conductive connection on vehicle motion Connect Multipurpose Cable There are three optional dongle cables for use with the multipurpose port VX89053C ABLE 1 D15 Connector to Thor VX9 2 D9 Serial Connector COM4 3 USB Connector VX89052C ABLE VX89A051CBLUSB These cables provide A USB type A plug e A COMA serial port connector or Both a USB Type A port and a COMA serial port Pin 9 of COMA provides 12V Verify acceptable input voltages before connecting serial devices Configuration of COM port power is handled via the VMT Manager option in the Control Panel For more information consult the Thor VX9 Reference Guide or the system administrator responsible for the configuration of the Thor VX9 The mul
31. t Cable Note Use of a shielded cable is required to maintain emissions and susceptibility compliance F i XC 1 Insert the network cable and ensure it is firmly seated in the connector jack 2 Toremove the Ethernet cable press the release tab on the cable end 3 4 Connect Serial Bar Code Scanner Refer to the documentation received with the bar code scanner for complete instructions Read all warnings and caution labels Pin 9 of COM1 provides 5V Do not connect a serial bar code scanner to COM2 or COM4 as this may damage the scanner the Thor VX9 or both Pin 9 of COM1 must be configured to provide 5V An LED illuminates near the COM1 connector when the 5V option is enabled The LED is off when RI is enabled Configuration of COM port power is handled via the VMT Manager option in the Control Panel For more information consult the Thor VX9 Reference Guide or the system administrator responsible for the configuration of the Thor VX9 The scanner cable is attached to the COM1 port The cable requires a nine pin D shell female connector for the Thor VX9 Note Use of a shielded cable is required to maintain emissions and susceptibility compliance 7 Seat the connector firmly over the pins and turn the thumbscrevvs in a clockwise direction Do not overtighten When you have finished using the scanner remove it from the Thor VX9 and store the scanner in a closed container or bag Refer to the documentation re
32. tio adentro Peligro de explosi n si la pila se reemplaza incorrectamente Reemplace solamente con el mismo tipo o equivalente recomendado por el fabricante ES Oppassen Bevat Lithium batterij Incorrrecte plaatsing van batterij kan leiden tot explosiegevaar Alleen vervangen door hetzelfde of door fabrikant aanbevolen gelijkwaardig type NL Lithium Battery Safety Statement continued TIpocoxi Yaapyet unatapia ano Abro cowmtepiKa Yuapyei xiv vvo xpn nc s v y avuxatactade pe Aav0acu vo tp ro AVTIKATOOTHOTE LLOVO pe TOV idto Y LGOSYVALLO TITO TOV ovytoT rut ad TOV KUTOGKEVAGTI GR m YFUVARMAADTWES Miko To b 2 741 RENET WCB xan BU TRETAS AREORA EAL TCH SV JP Dikkat inde lityum bataryas bulunur Bataryan n yanl de i tirilmesi patlama tehlikesi yarat r Ayn s yla veya reticinin nerdi i e de er tiple de i tirin TR FA JE MG 97 ME 2171 4 ANTAS AF FA ARO Qs FAA 4212 HE NA JAYA deys u Ele z ISANG KR wis ARB WEREKTL MAR AS JEL E Gi j 38 d28 698 Fl 3 101 SF 18 24T 26 9 CN Legend Chinese CN Danish DK Dutch NL English US Finnish Fl French FR German DE Greek GR Italian T Japanese JP Korean KR Norwegian NO Portuguese PT Spanish ES Swedish SE Turkish TR 4 4 Vehicle Power Supply Connection Safety Statement Vehicle
33. tipurpose cable is attached to the port The cable requires a nine pin D shell female connector for the Thor VX9 3 14 U EES 1 Seat the cable connector firmly over the pins and tum the thumbscrews in a clockwise direction Do not overtighten 2 1f a USB port is present plug the desired device such as a USB mouse or storage device into the USB port Refer to the Windows help system and the documentation for your USB device for more information USB devices may be installed removed or swapped without turning off the Thor VX9 3 If a COM4 port is present seat the serial device cable connector firmly over the pins and turn the thumbscrews in a clockwise direction Do not overtighten 3 15 3 16 Chapter 4 Product Agency Compliance Thor VX9 Class A Digital Device FCC Rules Part 15 This device complies with FCC Rules part 15 Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed