1. Beware of possible short circuits when connecting a cable section with conductive shielding braiding Safety Guidelines Housing Warning A Only technicians authorized by Hirschmann are permitted to open the housing Note The SPIDER is grounded via a pin of the 3pin terminal block Make sure that the electrical installation meets local or nationally applicable safety regulations A Warning The ventilation slits must not be covered so as to ensure free air cir culation The distance to the ventilation slots on the top and the bottom of the housing has to be a minimum of 10 cm The side distance of the SPIDER 4TX 1FX and SPIDER 8TX devi ces to neighbour devices has to be a minimum of 2 cm if the ambient temperature is higher than 50 C Never insert pointed objects thin screwdrivers wires etc into the inside of the subrack Failure to observe this point may result in inju ries caused by electric shocks Note If installed in a living area or office environment the device must be operated exclusively in switch cabinets with fire pro tection characteristics according to EN 60950 1 Note The housing has to be mounted in upright position Safety Guidelines Environment Warning A The device may only be operated in the listed ambient temperature range at the listed relative air humi dity non condensing The installation location is to be selec ted so as to ensure comp
2. 039669004030706000 Description and operating instructions Industrial ETHERNET Rail Switch 1 al EI n rcm al i al l me c al k i ro oom al i 2 l me EI k EI SPIDER 3TX TAP SPIDER 5TX SPIDER 8TX SPIDER 1TX 1FX SPIDER 5TX EEC SPIDER 8TX EEC SPIDER 1TX 1FX EEC SPIDER 1TX 1FX SM SPIDER 1TX 1FX SM EEC SPIDER 4TX 1FX SPIDER 4TX 1FX ST EEC SPIDER SPIDER 4TX 1FX EEC SPIDER 4TX 1FX SM EEC i i mi Be mi F mi Hirschmann Simply a good Connection HIRSCHMANN SPIDER xTX xFX The Rail Switches media converters SPIDER 3TX TAP SPIDER 5TX SPIDER 5TX EEC SPIDER 8TX SPIDER 8TX EEC SPIDER 1TX 1FX media converter SPIDER 1TX 1FX EEC media converter SPIDER 1TX 1FX SM media converter SPIDER 1TX 1FX SM EEC media converter SPIDER 4TX 1FX SPIDER 4TX 1FX EEC SPIDER 4TX 1FX ST EEC SPIDER 4TX 1FX SM EEC in short SPIDER are switches especially designed for use in industrial environments It supports ETHERNET 10 MBit s and Fast ETHERNET 100 MBit s The devices support switched ETHERNET networks in accordance with IEEE standard 802 3 or 802 3u using copper and fiber optic technology The devices are plugged onto the standard bar The SPIDER 3TX TAP SPIDER 5TX SPIDER 5TX EEC SPIDER 8TX SPIDER 8TX EEC devices have three five eight 10 100 MBit s twisted pair ports RJ45 connectors It is possible to connect up to three five eig
3. OL BuissoJ20jne ivis va Ajuejodoine HOd uojenoDeuojne OOL OL SJOJOOUUOD Gpf IvLs vd X L ASVEOOL OL S Jod spod g OOL OL IvLs vd L Mod 001 01 Xoolq euru uld yeolq Jeuiuue uid c O33 XLS 3GdldS X19 YACIdS ivis vd OOL OL iv1s vd OOL OL iv1s vd OOL OL iv1s vd OOL OL iv1s vd OOL OL d Bulssoso0 ne Aywejodoyne uojyenoDeuojne S10j9euuoo GpH 601 3Sv800L 0L spod g yeo q euru uid c O33 WS X3VXLI YACIdS INS XAVWX LLI Y3AldS O33 XJU XLI YACIdS XAL XLL s3dids 1 HOd IvLs va iv1s vd OOL OL d dVL X1 YAdIdS iv1s vd OOL OL iv1s vd OOL OL iv1s vd OOL OL d Bulssosoo0 ne Aysejodoyne uojyenoBeuojne S10j9euuoo GpH 601 38 v8001 0L pod 1 yoolq Jeuruo uid c Bulssoso0 ne Aysejodoyne uojenoBeuojne S10j9euuoo GpH 601 3Sv800L 0L Ssyod e yeo q euru uid c Fig 1 Overview interfaces display elements and controls of the SPIDER xTX xFX 1 Functional description The 10 100BASE T X ports of an SPIDER represent a terminal connection for the connected LAN segment You can connect single devices or complete network segments 1 1 FRAME SWITCHING FUNCTIONS Store and Forward All data received by the SPIDER from the system bus or at the ports are stored and checked for validity Invalid and defective frames gt 1 522 byte or CRC erro
4. RJ45 sockets 10 100 MBit s 1 FX port Duplex SC connection 100 MBit s multimode MM SPIDER 4TX 1FX ST EEC 4 TP TX ports RJ45 sockets 10 100 MBit s 1 FX port ST connector 100 MBit s multimode MM SPIDER 4TX 1FX SM EEC 4 TP TX ports RJ45 sockets 10 100 MBit s 1 FX port Duplex SC connection 100 MBit s singlemode SM SPIDER 3TX TAP 3 TP TX ports RJ45 sockets 10 100 MBit s SPIDER 5TX SPIDER 5TX EEC 5 TP TX ports RJ45 sockets 10 100 MBit s SPIDER 8TX SPIDER 8TX EEC 8 TP TX ports RJ45 sockets 10 100 MBit s Displays Equipment status 1x green LED P power supply voltage present Port status SPIDER 1TX 1FX 2 x green LEDs DA STAT data link status 1 x yellow LEDs 10 100 data rate TP port SPIDER 4TX 1FX 5 x green LEDs DA STAT data link status 4x yellow LEDs 10 100 data rate TP ports SPIDER 3TX TAP 3 x green LEDs DA STAT data link status 3 x yellow LEDs 10 100 data rate SPIDER 5TX SPIDER 5TX EEC 5 x green LEDs DA STAT data link status 5 x yellow LEDs 10 100 data rate SPIDER 8TX SPIDER 8TX EEC 8 x green LEDs DA STAT data link status 8 x yellow LEDs 10 100 data rate Scope of delivery Rail Switch SPIDER incl terminal block for supply voltage description and operating instructions Order number Rail Switch SPIDER 3TX TAP 943 899 001 Rail Switch SPIDER 5TX 943 824 002 Rail Switch SPIDER 5TX EEC 943 824 102 Rail Switch SPIDER 8TX 943 376 001 Rail Switch SPIDER 8TX EEC 943 376 201 Rail Switc
5. level 3 EN 61000 4 3 Test level 3 EN 61000 4 4 Test level 3 EN 61000 4 5 Test level 2 EN 61000 4 5 Test level 3 EN 61000 4 6 Test level 3 EMC emitted immunity EN 55022 FCC 47 CFR Part 15 Class A Class A Stability Vibration Shock IEC 60068 2 6 Test FC testing level in line with EN 61131 2 2003 IEC 60068 2 27 Test Ea testing level in line with EN 61131 2 2003 Certifications cUL 508 CSA 22 2 No 142 E175531 Network size TP port 10BASE T 100BASE TX Length of a twisted pair segment 100 m 328 ft maximum F O port 100BASE FX According to IEEE 802 3u 100BASE FX System attenuation 50 125 um fiber multimode MM 0to8dB 62 5 125 um fiber multimode MM 0 to 11 dB 9 125 um fiber singlemode 0 to 16 dB SPIDER TX 1FX SM Wave length SM 1300 nm F O line length example 50 125 um fiber multimode MM 5 km approx data of fiber 1 0 dB km 800 MHz km 62 5 125 um fiber multimode MM 4 km approx data of fiber 1 0 dB km 500 MHz km 9 125 um fiber singlemode SM 30 km approx data of fiber 1300 nm 0 4 dB km SPIDER TX 1FX SM Interfaces SPIDER 1TX 1FX SPIDER 1TX 1FX EEC 1 TP TX port RJ45 socket 10 100 MBit s 1 FX port Duplex SC connection 100 MBit s multimode MM SPIDER 1TX 1FX SM SPIDER 1TX 1FX SM EEC 1 TP TX port RJ45 socket 10 100 MBit s 1 FX port Duplex SC connection 100 MBit s singlemode SM SPIDER 4TX 1FX SPIDER 4TX 1FX EEC 4 TP TX ports
6. on a 35 mm standard bar to DIN EN 50 022 Attach the upper snap on slide bar of the SPIDER to the standard bar and press it down until it locks in position Fit the signal lines Notes The SPIDER is grounded via a pin of the terminal block Do not open the housing The shielding ground of the twisted pair lines which can be connected is electrical ly connected to the ground connection z c Fig 5 Assembling the SPIDER Fig 6 Dimensions uus Fig 4 Configuration with SPIDER Connection of depending on product type up to 8 data terminal equipments or further segments via TP and up to 1 data terminal equipment or further segment via F O 3 3 STARTUP PROCEDURE You start up the SPIDER by connecting the supply voltage via the 3 pin terminal block 3 4 DISMANTLING To take the SPIDER off the ISO DIN rail unlock the snap in mechanism according to Fig 7 Fig 7 Dismantling the SPIDER 4 Further support In the event of technical queries please talk to the Hirschmann contract partner respon sible for looking after your account or directly to the Hirschmann office You can find the addresses of our contract partners on the Internet http www hirschmann ac com Our support line is also at your disposal Tel 49 1805 14 1538 Fax 49 7127 14 1551 Answers to Frequently Asked Questions can be found on th
7. 13 g 0 25 Ib 177 g 0 39 Ib 105 g 0 23 Ib 120 g 0 27 Ib SPIDER 3TX TAP SPIDER 5TX SPIDER 5TX EEC SPIDER 8TX SPIDER 8TX EEC SPIDER 1TX 1FX SPIDER 4TX 1FX Ambient temperature Surrounding air 0 C to 60 C 32 F to 140 F 40 C to 70 C 40 F to 158 F 40 C to 75 C 40 F to 167 F SPIDER 3TX TAP SPIDER 5TX SPIDER 8TX SPIDER 1TX 1FX SPIDER 1TX 1FX SM SPIDER 4TX 1FX SPIDER 4TX 1FX EEC SPIDER 4TX 1FX ST EEC SPIDER 4TX 1FX SM EEC SPIDER 5TX EEC SPIDER 8TX EEC SPIDER 1TX 1FX EEC SPIDER 1TX 1FX SM EEC Storage temperature Surrounding air 40 C to 70 C 40 F to 158 F 40 C to 85 C 40 F to 185 F SPIDER 3TX TAP SPIDER 5TX SPIDER 8TX SPIDER 1TX 1FX SPIDER 1TX 1FX SM SPIDER 4TX 1FX SPIDER 1TX 1FX EEC SPIDER 1TX 1FX SM EEC SPIDER 4TX 1FX EEC SPIDER 4TX 1FX ST EEC SPIDER 4TX 1FX SM EEC SPIDER 5TX EEC SPIDER 8TX EEC Humidity up to 95 non condensing Atmospheric pressure up to 2000 m 795 hPa higher altitudes on demand Pollution Degree 2 Laser protectionz Class 1 conforming to EN 60825 1 SPIDER 1TX 1FX SPIDER 4TX 1FX Protection type IP 30 Interference proof Discharge of static electricity Contact discharge Air discharge Electromagnetic fields Fast transients Surge voltage symmetrical Surge voltage asymmetrical Cable based RF faults EN 61000 4 2 Test level 3 EN 61000 4 2 Test
8. ER 5TX EEC Eight ports port 1 to 8 SPIDER 8TX SPIDER 8TX EEC 10 100 Mbit s 8 pin R45 sockets allow ter minal equipment or depending on type up to eight independent network segments complying with the standards IEEE 802 3 100BASE TX 10BASE T to be connected These ports support autonegotiation auto polarity and autocrossing Pin configuration of the RJ45 socket 1 line pair pin 3 and pin 6 1 line pair pin 1 and pin 2 remaining pins not used nc Ping n c Pin7 TD Pin6 nc Pind nc Pin4 TD Pin3 RD Pin2 RD Pin1 Fig 2 Pin configuration of an TP interface 100 Mbit s connection FX port The 100 MBit s ports of the SPIDER 1TX 1FX SPIDER 4TX 1FX supports the IEEE 802 3 100BASE FX FDX standard The devices SPIDER 1TX 1FX SPIDER 1TX 1FX EEC SPIDER 1TX 1FX SM SPIDER 1TX 1FX SM EEC SPIDER 4TX 1FX SPIDER 4TX 1FX EEC SPIDER 4TX 1FX SM EEC use a duplex SC connector the SPIDER 4TX 1FX ST EEC uses a ST connector The 100 MBit s port allows one further DTE or an optical network component to be connected 3pin terminal block The supply voltage is connected via a 3pin terminal block Note Terminal tightening torque of line binding screws 0 5 Nm A Warning The SPIDER devices are designed for operation with a safety extra low voltage Thus they may only be connected to the supply voltage connections with PELV cir
9. al Hirschmann sales partner or directly from the Hirschmann office address refer to chapter entitled Notes on CE identification Safety Instructions This manual contains instructions which must be observed to ensure your own per sonal safety and to avoid damage to devices and machinery The instructions are highlighted with a warning triangle and are shown as follows according to the degree of endan germent A Danger means that death serious injury or considerable damage to property will result if the appropriate safety measures are not taken Warning means that death serious injury or considerable damage to property can result if the appropriate safety measures are not taken Caution means that light injury or damage to property can result if the appropria te safety measures are not taken A Note is an important piece of information about the product how to use the product or the relevant section of the documentati on to which particular attention is to be drawn Certified usage Please observe the following A Warning The device may only be employed for the purposes described in the catalog and technical description and only in conjunction with external devices and components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and correctly Furthermore it must be operate
10. ance of the SPIDER 1TX 1FX SPIDER 4TX 1FX can be monitored in receiving direction as well as in transmitting direction if the other side also supports Far End Fault If the other side does not support Far End Fault the optical transmission distance is monitored only in receiving direction Far End Fault is sent if the optical input power at the optical port has fallen under the low light level If Far End Fault is re ceived the link stays inactive DA STAT LED dark 1 4 FURTHER FUNCTIONS AND FEATURES Reset The SPIDER will be reset by the following action input voltages fall below a threshold After a reset the following action is carried through initialization 1 5 DISPLAY ELEMENTS Equipment status These LEDs provide information about statuses which affect the function of the entire SPIDER P Power green LED lit supply voltage present Port Status These LEDs display port related information DA STAT Data Link status green LED not lit no valid link lit green valid link flashes green data traffic 10 100 Data rate yellow LED Twisted Pair Ports leuchtet nicht 10 Mbit s link leuchtet yellow 100 Mbit s link 1 6 INTERFACES 10 100 MBit s connection One port port 2 SPIDER 1TX 1FX Three ports port 1 to 3 SPIDER 3TX TAP Four ports port 2 to 5 SPIDER 4TX 1FX Five ports port 1 bis 5 SPIDER 5TX SPID
11. as careful operati on and maintenance are essential in ensuring safe and reliable operation of this device Use only undamaged parts These products are only to be used in the manner indicated in this version of the Description and Operating Instructions Particular attention is to be paid to all warnings and items of information relating to safety A Warning Any work that may have to be per formed on the electrical installation should be performed by fully quali fied technicians only Warning SPIDER 1TX 1FX SPIDER 4TX 1FX LED or LASER components accor ding to IEC 60825 1 2001 CLASS 1 LASER PRODUCT LIGHT EMITTING DIODE CLASS 1 LED PRODUCT A Based specifications and standards The devices fulfil the following specifications and standards EN 61000 6 2 2001 Generic standards Immunity for industrial environments EN 55022 1998 A1 2000 A2 2003 Information technology equipment Radio disturbance characteristics EN 60950 1 2001 Safety of Information Technology Equipment ITE EN 61131 2 2003 Programmable Control lers FCC 47 CFR Part 15 2004 Code of Federal Regulations cUL 508 1998 Underwriters Labratories Inc Safety for Industrial Control Equipment Certified devices are marked with a certification identifier Notes on CE identification The devices comply with the regula tions of the following European direc
12. cuits or alternatively SELV circuits with the voltage restrictions in accordance with IEC EN 60950 1 Voltage supply The supply voltage is electrically isolated from the housing Ground connection The SPIDER is grounded via a pin of the 3pin terminal block Fig 3 Pin configuration of 3pin terminal block 2 Configuration 2 1 CONNECTING DTE AND OTHER NETWORK SEGMENTS It is possible to connect with SPIDER 3TX TAP up to three SPIDER 5TX SPIDER 5TX EEC up to five SPIDER 8TX SPIDER 8TX EEC up to eight SPIDER 1TX 1FX up to one SPIDER 4TX 1FX up to four data terminal equipments DTE or other network segments to the 10 100 Mbit s ports using twisted pair cabling ref Fig 4 One further data terminal equipment or optical network component can be connec ted at 100 Mbit s to the optical port of the SPIDER 1TX 1FX SPIDER 4TX 1FX using fiber optic cable 3 Assembly startup procedure and dismantling 3 1 UNPACKING CHECKING Check whether the package was deliver ed complete see scope of delivery Check the individual parts for transport damage A Warning Use only undamaged parts 3 2 ASSEMBLY The equipment is delivered in a ready to operate condition The following procedure is appropriate for assembly SPIDER Pull the terminal block off the SPIDER and wire up the supply voltage lines Fit the SPIDER
13. d and serviced carefully Safety Guidelines Power Supply Switch the basic devices on only when the case is closed A Warning The devices may only be connected to the supply voltage shown on the type plate The devices are designed for opera tion with a safety extra low voltage Thus they may only be connected to the supply voltage connections with PELV circuits or alternatively SELV circuits with the voltage restrictions in accordance with IEC EN 60950 1 For the case where the module is opera ted with external power supply Use only a safety extra low voltage in accordance with IEC EN 60950 1 to power the system First of all you connect the ground connection before you establish the further connections When you remove connec tions you disconnect the ground connec tion last Relevant for North America The subject unit is to be suppplied by a Class 2 power source complying with the requirements of the National Electrical Code table 11 b Relevant for North America Power input and output I O wiring must be in accordance with Class I Division 2 wiring methods Article 501 4 b of the National Electrical Code NFPA 70 and in accordance with the authority having juris diction Peripheral equipment must be suitable for the location it is used in Use 60 75 C or 75 C copper CU wire only Safety Guidelines Shielding Ground
14. d regularly Any cor rections which prove necessary are contai ned in subsequent editions We are grateful for suggestions for improvement We reserve the right to make technical modifications Permission is not given for the circulation or reproduction of this document its use or the passing on of its contents unless gran ted expressly Contravention renders the perpetrator liable for compensation for damages All rights reserved in particular in the case of patent grant or registration of a utility or design Copyright Hirschmann Automation and Control GmbH 2006 All Rights Reserved Note We would point out that the content of these operating instructions is not part of nor is it intended to amend an earlier or exi sting agreement permit or legal relation ship All obligations on Hirschmann arise from the respective purchasing agreement which also contains the full warranty condi tions which have sole applicability These contractual warranty conditions are neither extended nor restricted by comments in these operating instructions We would furthermore point out that for reasons of simplicity these operating instructions cannot describe every conceivable problem associated with the use of this equipment Should you require further information or should particular problems occur which are not treated in sufficient detail in the operating instruc tions you can request the necessary infor mation from your loc
15. e Hirschmann product site http www hirschmann ac com The FAQs are located under Service in the Automation and Network Solutions section www hicomcenter com gives you an up to date overview of training courses about technology and products 5 Technical data General data Operating voltage Buffer time NEC Class 2 power source 9 6 VDC 32 0 VDC safety extra low voltage SELV PELV 5 A maximum min 10 ms at 20 4 VDC Potential difference between input voltage and housing Potential difference to input voltage 24 VDC 32 VDC Potential difference to input voltage ground 32 VDC Current consumption at 24 VDC 2 2 W maximum 7 5 Btu IT h 2 2 W maximum 7 5 Btu IT h 3 9 W maximum 13 3 Btu IT h 3 0 W maximum 10 2 Btu IT h 3 9 W maximum 13 3 Btu IT h SPIDER 3TX TAP SPIDER 5TX SPIDER 5TX EEC SPIDER 8TX SPIDER 8TX EEC SPIDER 1TX 1FX SPIDER 4TX 1FX Dimensions WxHxD 25 mm x 114 mm x 79 mm 1 0 in x 4 5 in x 3 2 in 25 mm x 114 mm x 79 mm 1 0 in x 4 5 in x 3 2 in 40 mm x 114 mm x 79 mm 1 6 in x 4 5 in x 3 2 in 25 mm x 114 mm x 79 mm 1 0 in x 4 5 in x 3 2 in 25 mm x 114 mm x 79 mm 1 0 in x 4 5 in x 3 2 in 25 mm x 126 mm x 79 mm 1 0 in x 5 0 in x 3 2 in SPIDER 3TX TAP SPIDER 5TX SPIDER 5TX EEC SPIDER 8TX SPIDER 8TX EEC SPIDER 1TX 1FX SPIDER 4TX 1FX SPIDER 4TX 1FX EEC SPIDER 4TX 1FX SM EEC SPIDER 4TX 1FX ST EEC Weight 113 g 0 25 Ib 1
16. gned to provide reasonable protection against harmful inter ference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inter ference at his own expense Recycling Note After its use this product has to be processed as electronic scrap and disposed of according to the prevai ling waste disposal regulations of your community district country state snes ur eed IV1S va eje ejeq JOMOd snijeis yur ejeg IVLS vd ejejeg 004 04 JOMOd d Sjueuis o fe dsip q31 OOL OL d eo sjueuieje Aejdsip q31 Z uod y uod 9 uog 8 uod iis ivLls vd OOL OL ivls vd OOL OL ivls vd OOL OL ivls vd OOL OL SjueuJs o OOL OL Ae dsip q31 d O33 X18 YAdIdS X18 d3GldS O33 INS X3V XLY 3GldS O33 LS XJU XLY YACIdS O33 XJV XLv YACIdS XAWXLr YACIdS 1 uog IvLs va ivis vd OOL OL ivis vd OOL OL ivis vd Bulssoso0 ne Aysejodoyne uojenoBeuojne S10j9euuoo Gp 601 3Sv800L 0L spod p 001 01 lv1s va Ivis va Mod OOL
17. h SPIDER 1TX 1FX 943 890 001 Rail Switch SPIDER 1TX 1FX EEC 943 927 001 Rail Switch SPIDER 1TX 1FX SM 943 891 001 Rail Switch SPIDER 1TX 1FX SM EEC 943 928 001 Rail Switch SPIDER 4TX 1FX 943 221 001 Rail Switch SPIDER 4TX 1FX EEC 943 221 101 Rail Switch SPIDER 4TX 1FX ST EEC 943 914 001 Rail Switch SPIDER 4TX 1FX SM EEC 943 880 001 Accessories ETHERNET manual 943 320 011 Manual Basics Industrial ETHERNET and TCP IP 280 720 834 Rail Power Supply RPS 30 943 662 003 Rail Power Supply RPS 60 943 662 001 Rail Power Supply RPS 120 943 662 011 Hirschmann Automation and Control GmbH Stuttgarter StraRe 45 51 D 72654 Neckartenzlingen Germany Tel 49 1805 14 1538 Fax 4449 7127 14 1551 E Mail hac support hirschmann de Internet http www hirschmann com Printed in Germany Subject to alterations
18. ht data terminal equipments or other network segments to the TP ports using twi sted pair cabling The SPIDER 1TX 1FX devices have one 10 100 MBit s twisted pair port RJ45 connectors and one 100 MBit s fiber optic port 100BASE FX Duplex SC connector It is possible to connect one data terminal equipments or other network segments to the TP ports using twisted pair cabling One further DTE or optical network component can be connected to the fiber port The SPIDER 4TX 1FX devices have four 10 100 MBit s twisted pair ports RJ45 connectors and one 100 MBit s fiber optic port 100BASE FX Duplex SC connector or ST connector on SPIDER 4TX 1FX ST EEC It is possible to connect up to four data terminal equipments or other network segments to the TP ports using twisted pair cabling One further DTE or optical network component can be connected to the fiber port The TP ports support autonegotiation auto polarity and autocrossing The fiber optic port of the SPIDER 1TX 1FX and SPIDER 4TX 1FX supports full duplex FDX The performance features described here are binding only if they have been expressly guaranteed in the contract We have checked that the contents of the technical publication agree with the hardware and software described However it is not possi ble to rule out deviations completely so we are unable to guarantee complete agree ment However the details in the technical publication are checke
19. liance with the cli matic limits listed in the Technical Data To be used in an up to Pollution Degree 2 environment only IEC 60664 1 Staff qualification requirements Note Qualified personnel as understood in this manual and in the warning signs are persons who are familiar with the setup assembly startup and operation of this product and are appropriately qualified for their job This includes for example those persons who have been trained or directed or authorized to switch on and off to ground and to label power circuits and devices or systems in accordance with current safety enginee ring standards trained or directed in the care and use of appropriate safety equipment in accor dance with the current standards of safety engineering trained in providing first aid General Safety Instructions This device is electrically operated Adhere strictly to the safety requirements relating to voltages applied to the device as described in the operating instructions A Warning Failure to observe the information given in the warnings could result in serious injury and or major damage Only personnel that have received appropriate training should operate this device or work in its immediate vicinity The personnel must be fully familiar with all of the warnings and maintenance measures in these operating instructions Correct transport storage and assembly as well
20. om which it does not receive a link test pulse Note A non occupied interface is assessed as a line interrupt The TP line to terminal equipment which is switched off is likewise assessed as a line interrupt as the de energised bus coupler cannot transmit link test pulses Auto polarity exchange If the receive line pair is incorrectly connec ted RD and RD switched polarity is auto matically reversed Autonegotiation Autonegotiation is a procedure in which the switch automatically selects the operating mode of its 10 100 RJ 45 ports When a connection is set up for the first time the switch detects the speed 10 or 100 Mbit s and the transmission mode of the connec ted network half duplex or full duplex Autocrossing The SPIDER detects the transmit and recei ve pairs MDI MDI X The SPIDER automa tically configures its port for the correct transmit and receive pins Consequently it does not matter whether you connect devi ces using a cross over or straight cable 1 3 SPECIFIC FUNCTIONS OF THE F O INTERFACE Link control The device SPIDER 1TX 1FX SPIDER 4TX 1FX monitors the connected F O line for inter rupts in accordance with IEEE standard 802 3 100BASE FX Low Light Detection If the optical input power decreases below the low light threshold the transmit and receive path will be disabled for data and the idle signal will be transmitted Far End Fault The optical transmission dist
21. r as well as fragments lt 64 byte are discarded The SPIDER forwards the valid frames Multi address capability A SPIDER learns all source addresses per port Only packets with unknown addresses addresses learnt at this port a multi broadcast address in the destination address field are sent to this port A SPIDER learns up to 1 000 addresses This becomes necessary if more than one termi nal device is connected to one or more ports In this way several independent sub networks can be connected to an SPIDER Learnt addresses An SPIDER monitors the age of the learned addresses The SPIDER deletes address entries from the address table which exceed a certain age 300 seconds Note Restarting deletes the learned address entries Tagging IEEE 802 10 The IEEE 802 1 O standard designates the VLAN tag to be included in a MAC data frame for the VLAN and prioritizing func tions The VLAN tag consists of 4 bytes 2 bytes tag protocol identifier TPID 2 bytes tag control information TCI It is inserted between the source address field and the type field Data packets with VLAN tag are transmitted unchanged by the SPIDER 1 2 SPECIFIC FUNCTIONS OF THE TP TX INTERFACE Link control The SPIDER monitors the connected TP line segments for short circuit or interrupt using regular link test pulses in accordance with IEEE standard 802 3 10BASE T 100BASETX The SPIDER does not transmit any data to a TP segment fr
22. tive 89 336 EEC Council Directive on the harmoniza tion of the legal regulations of mem ber states on electromagnetic com patibility amended by Directives 91 263 EEC 92 31 EEC and 93 68 EEC SPIDER 5TX EEC 72 245 EEC 2005 83 EG Radio interference electromagnetic compatibility in vehicles Certified devices are marked with a e1 certification identifier Ce The EU declaration of conformity is kept available for the responsible authorities in accordance with the above mentioned EU directives at Hirschmann Automation and Control GmbH Stuttgarter Stra e 45 51 D 72654 Neckartenzlingen Telefon 49 0 1805 14 1538 The product can be used in the resi dential sphere residential sphere business and trade sphere and small companies and in the industrial sphere Interference immunity EN 61000 6 2 2001 Radio interference level EN 55022 1998 A1 2000 A2 2003 Class A Warning This is a Class A device This equip ment may cause radio interference if used in a residential area in this case it is the operator s responsibili ty to take appropriate measures The precondition for compliance with EMC limit values is strict adhe rence to the construction guidelines specified in this description and operating instructions FCC Note This equipment has been tested and found to comply with the limits for a Class A digi tal device persuant to part 15 of the FCC Rules These limits are desi