Home
ClimaRad user manual 2005.005.EN.w
Contents
1. Local load balanced ventilation system with heat recovery combined with CH system User manual Warranty ClimaRad Sensotronic control panel luchtkwaliteit sensorgestuurd handbediening snelheid 0 o o hd 1u 30 6u V M NEN XE IE INDOOR AIR QUALITY aan basisventilatie INTELLIGENT CO HUMIDITY CONTROL pauze maximum koele lucht 1 sign air quality 6 button sensor control sign locked base ventilation 2 sign fan speed 11 sign malfunction 3 button decrease C Onor puton pause 12 sign filter polluted 4 settings scale 5 positions On7 Ors Dutton maximum 13 sign base ventilation on off button cool air 5 button increase 9 14 sign manual control ClimaRad User Manual ClimaRad User Manual Copyright 2005 ClimaRad B V All rights reserved Nothing of this publication may be multiplied or published by means of print photocopy microfilm or any other way without prior permission of ClimaRad B V ClimaRad is a patented climate system ClimaRad is a registered trademark of ClimaRad B V Disclaimer Specifications can change without prior notice No liability whatsoever is accepted for any direct or indirect damage from using the information presented in this publication Preface Dear ClimaRad user The ClimaRad heating and ventilation system will supply your home with warm and clea
2. 29 Inspection and cleaning of facade outlets If possibel regularly check the intake and exhaust grills on the facade especially on the ground floor Dirt leaves and insects may block the air passage If necessary dismount the grills and clean the anti insect grid In some cases where you cannot access the facade openings from the outside it is possible to clean the duct and anti insect grill from the inside using a vacuum cleaner that can blow out air Some vacuum cleaners have the option to connect the hose to the outlet and thereby allowing cleaning the air ducts by blowing If this j ble nl he ClimaRad install the anti insect grids in a maintenance visit The installer can apply a compressor to blow clean the anti insect grids and the grills from the inside 24 Trouble shooting There is no light showing on the control panel v The unit isn t connected to the electric mains Check whether the plug is connected to the wall socket 230 V 50 Hz v The unit is switched off Switch it on using the on off switch at the left bottom side of the ClimaRad ventilation unit v The wire of the control panel is damaged or not connected Check the connectors of the wire to both the control panel and the ClimaRad ventilation unit Make sure the connectors are snapped in correctly If the wire is damaged have it replaced by your ClimaRad installer v The backlight of the control panel is switched of
3. gt e The default maximum flow rate is 100 m3 h Using the and buttons you can change this value e Boost off press the boost button This will immediately stop the boost mode and the unit returns to the sensor controlled mode and vent accordingly Night Cooling During the summer months it is often cool in the evening and at night You can use this fresh air to cool your house by using the Night Cooling mode When this mode is activated the ClimaRad compares the inside and outside temperature and if the outside air is sufficiently colder the ClimaRad will blow the cold outside air into your room for 6 hours No room air is extracted After 6 hours the ClimaRad automatically returns to the sensor controlled mode and vent accordingly The default factory setting for the ventilation rate is 100 m3 h Using the and buttons you can change this ventilation rate e Night Cooling on press the Cool Air button The ClimaRad unit will run both fans for a short while to measure inside and outside air temperature During this preparatory stage the Cool Air indicator light will blink If the temperature difference is high enough the cooling phase will start and last for 6 hours If there is not enough temperature difference the ClimaRad unit will wait for 15 minutes before doing another measurement e Night Cooling off press the Cool Air button again This immediately ends the Night C
4. Ergo you can never have enough fresh air But there is a snag Ventilation also requires energy not only to run the fans but especially because fresh air is also cold air that needs to be heated to room temperature In modern buildings these so called ventilation losses may account to as much as 50 of the total heating costs Because of this modern or refurbished houses are usually as air tight as possible and the inhabitants are stuck with a dilemma How do I get a good indoor air quality without wasting energy ClimaRad is your answer It provides healthy ventilation and it saves energy CO Indoor Air Quality and ClimaRad People produce CO and humidity through breathing In occupied badly vented rooms the CO concentration will increase rapidly High concentrations of CO are not damaging on the short term but they create a damp and smelly indoor climate If people stay in such a climate for a longer period it may irritate eyes throat and nose Also most obvious at work or school higher CO concentrations are known to affect the ability to concentrate Apart from that CO is an important indicator for the presence of other hazardous substances VOCs solvents formaldehyde radon fine dust particles etc that can be detrimental to your health In other words a CO concen tration below certain threshold values usually guarantees a good indoor air quality overall The table below shows threshold values for CO
5. back into position Secure the filter holder using the 2 Screws Please make sure the filter holder is closed correctly This is very important for a proper functioning of the unit Finally turn the ClimaRad back on main switch Inspection and cleaning of air ducts Your ClimaRad has two air ducts that go through the facade One intake duct for fresh air and an exhaust duct to expel room air The round air ducts connect to the backside of the ClimaRad ventilation unit and go straight through the outside wall i HAHI Sasi s lt Inspection of the air ducts T First switch the ClimaRad off switch at the bottom left Tilt the ClimaRad radiator forward 1 Remove the metal dust cover on top of the ClimaRad ventilation unit 2 Remove the two blue and round inspection covers by turning them 350 degrees counter clockwise 1 and pulling them out 2 This gives access to the air ducts for inspection and cleaning Cleaning the air ducts Do not sharp or pointed objects for cleaning as they may damage the air ducts Do not use water directly because this may short circuit the electric and electronic parts of the unit A humid cloth is allowed Parts of the air ducts that are accessible by hand can be cleaned using a soft dry or humid cleaning cloth If the ducts are very polluted with dust it is advisable to use a vacuum cleaner
6. concentration that are used in practice Desired CO concentrations indoor climate Nominal 1200 ppm CO 80 satisfied 1000 ppm CO People with respiratory problems 800 ppm CO The ClimaRad Sensotronic features a CO sensor that measures the CO level and automatically adjusts the fan speed to maintain the desired level Thus the ClimaRad always provides the adequate ventilation Humidity and ClimaRad Every day several litres of condense and humidity are released in a house because of the presence of people and certain activities like cooking washing and cleaning Apart from that in new homes humidity may stem from the building construction Mites fungi and rot thrive on a high humidity level in the house The mites and fungi can cause allergies and wood rot can be detrimental to the building construction Adequate ventilation can prevent high humidity The ClimaRad has a humidity sensor that will react to high humidity levels and try to lower it in an intelligent way For instance if in rare cases the absolute outdoor humidity is higher no extra ventilation will occur Outside Air and ClimaRad Depending on where you live outdoor air may be polluted with allergenics pollen exhaust fumes benzene lead and fine dust particles Obviously these substances are not desired indoors There are two types of filters available for the intake duct of a ClimaRad to remove these substances e A fine dust a
7. according to EN442 at 75 65 20 C ClimaRad BV Reutummerweg 18 7651 KL Tubbergen NL Telephone 31 0 546 622 127 Fax 31 0 546 622 385 E mail info climarad com Website www climarad com Air filters can be ordered at www climarad com or at your ClimaRad installer 2005 ClimaRad BV 2005 005EN w
8. filled PP with halogen free flame retardants Dimensions unit Weight unit Material of the housing Housing of electronics Sensotronic Control Automatic control of indoor air quality Option to switch to manual control Timer controlled functions Pause Boost and Night Cooling Indicators Filter polluted Malfunction Lock Base ventilation Range of air quality settings in sensor controlled operation 800 1000 1200 1400 1600 ppm CO if needed other values can be programmed CO sensor non dispersive infra red self calibrating range 0 2000 ppm Range of ventilation capacity settings in manual control 20 40 60 80 en 100 m3 hr or Base ventilation 5 m3 hr on average ClimaRad radiator Type 11 single panel with single convector Type 22s double panel with double convector Models Balance and Tec type 11 759 1973 watt and type 22S 1524 3893 watt height 480 mm length 1280 to 2400 mm height 515 mm length 1280 to 2400 mm height 615 mm length 1280 to 2400 mm Model Classic type 11 1018 2220 watt height 500 mm length 1280 to 2400 mm height 600 mm length 1280 to 2400 mm Model Wing type 11 759 1973 watt height 500 mm length 1280 to 2400 mm height 550 mm length 1280 to 2400 mm height 650 mm length 1280 to 2400 mm sound source measured in a soundproof room with uninstalled but operational ventilation unit and no radiator thermal power rating
9. radiator tilts forward too fast v The weight of a ClimaRad radiator tilting forward is compensated by a patented construction in the radiator supports to ensure safe and easy tilting action Turn the appropriate bolts in the radiator supports see illustration on the right clockwise to increase the compensation energy De ClimaRad radiator cannot tilt forward at all v The hinges of the radiator supports are blocked Check for any objects blocking the mechanism Position of the two adjustmnent bolts If you don t succeed in solving the problem in an easy way ask for the assistance of a qualified ClimaRad installer For your own safety and possible damage to the unit dis mounting and opening of the ClimaRad housing should be left to a qualified ClimaRad installer 27 Technical specifications ClimaRad ventilation unit Power supply 230 V 50 Hz Fans 28 V DC motors 2x Flow rate in 6 steps from 0 to max 100 m3 h Rated power 65W Electricity consumption at 20 m3 hr ca 7 W at 40 m3 hr ca 10 W at 60 m3 hr ca 15 W at 80 m3 hr ca 25 W at 100 m3 hr ca 37 W Stand by el consumption 1 5 W Noise ca 28 dBA at 40 m3 uur Heat exchanger efficiency gt 80 material PP Air filters standard 2 x HAF filter 3M other filters available on request height 512 mm length 1135 mm depth 104 mm 16 kg including mounting frame excluding wall duct kit talcum filled PP talcum
10. 2 level and will automatically reduce the fanspeed Even opening a window doesn t escape the attention of the Sensotronic and it will cut back the fan speed without the user having to lift a finger Always a good indoor air quality at the lowest possible energy bill That is what the ClimaRad has to offer 2 Sensotronic How does the ClimaRad work The ClimaRad system is a combined heating and ventilation system especially developed for individual dwellings in residential and commercial buildings In every dwelling the ClimaRad takes care of the indoor climate independently of the number of people present Its very short intake and exhaust ducts do not require a complex air duct network in the home making it the ideal system to install and maintain in both new and renovated houses The ClimaRad Parts The ClimaRad system consists of the following parts 1 the ClimaRad radiator 2 the ClimaRad balanced ventilation unit 3 the ClimaRad mounting frame and radiator supports 4 the ClimaRad wall ducts Depending on the configuration you ordered a control panel is also part of your ClimaRad ClimaRad radiator The ClimaRad is shipped with a specially developed one or two panel radiator This radiator is connected to a conventional CH system with flexible piping Once mounted on its special supports it can be tilted forward to allow for easy access to the ClimaRad balanced ventilation unit e
11. See chapter on Turn Backlight On Off The fans don t work Sensotronic v The air quality is high enough When the desired air quality is reached the fans don t work This is normal operation behaviour If you want to activate the fans anyway v Increase the desired air quality pressing the button on your control panel After a while the ClimaRad fans will start to work v Press the boost button The ClimaRad will now run at maximum speed for 30 minutes unless you press the boost button again to make it return to normal operation v Press the on button to activate the base ventilation This forces the ClimaRad to switch on a couple of times per hour to maintain a minimum overall ventilation rate of 5 m3 hr independently of the air quality level The fans are turning but I don t feel much air coming out of the unit v Fans are running at a low speed To avoid discomfort draughts noise the ClimaRad s air inlet and outlet have a large surface area which makes low ventilation rates hard to detect v The air filters and or air ducts are blocked Check the filters and air ducts See instructions in the appropriate chapters v If the filters and air ducts are free the heat exchanger may be polluted In that case contact your ClimaRad installer The fans are running very fast Sensotronic v The air quality is bad The ClimaRad Sensotronic tries to achieve the desired air quality by turning up the flow ra
12. arts and slide them back in the appropriate slots No tools are required schoon ever nn cr r e n gt nn TAA Aid PN hM ewe hey per iex SAFES NC Oy Sy zwaar vervuild 19 20 4 Closing the filter holder A Tilt the filter holder upwards 1 B Close the filter holder clipping on the three clamps inserted in the filter holder and are not sticking out Also make sure that the area between the filter holder and the housing is completely free of any tools or other objects This can damage the filter holder and cause air leakage Please make sure the filters are completed Once the filter holder is closed put the metal dust cover back on top of the ventilation unit tilt the radiator back into vertical position and turn the ClimaRad back on 5 Reset the filter inspection counter To reset the filter inspection counter to zero after the filter is replaced press the and button on the control panel simultaneously during 4 seconds The text filter vervuild filter polluted will now disappear from the control panel Inspection and cleaning replacement of the air exhaust filter This filter is positioned at the bottom of the ClimaRad where the air is extracted from the room For a visible inspection e g using a torch light you can see the filter and assess the filter s colour that indicates the degr
13. ction and replacement of the filter see the chapter on Maintenance Malfunction e If there is a malfunction in the ClimaRad the X symbol will light up on the control panel Using the Trouble Shooting guide Chapter 6 you can try to find the cause of the malfunction and what you can do to repair the malfunction Please limit yourself to simple and easy inspections of the air ducts filters and electrical connections If this does not help you should ask a qualified ClimaRad installer for assistance Warning Never remove bolted parts of the housing or the wiring Opening the ClimaRad can lead to electric shocks and irreparable damage to the device 17 5 Maintenance As every ventilation system the ClimaRad needs maintenance to guarantee a problem free operation The maintenance on the ClimaRad is limited to a periodical inspection and occasional replacement of air filters as well as Cleaning of the air ducts Warning Never unscrew any parts of the ClimaRad housing This can lead to electric shocks and irreparable damage to the device Air Filters The ClimaRad ventilation unit has two filters an air intake filter and an exhaust filter The air intake filter is very important because it removes pollen dust and several allergenic substances from the incoming air In other words substances you would rather not have in your longs The function of the exhaust filter is to guarantee an appropria
14. e there is always a minimum ventilation rate even at correct CO2 level Factory setting of the ventilation rate for the base ventilation is set at 5 m3 per hour This means the ClimaRad ventilation unit will vent a few times per hour at the lowest ventilation rate e Base ventilation on press the base ventilation button e The text basisventilatie will light up on the panel M gt basisventilatie A N e Base ventilation off press the base ventilation button again The text basisventilatie will disappear Pause If you want to stop the ClimaRad fans for a short time e g when there is a stench outside you can use the Pause button to temporarily deactivate the unit for an hour After 60 minutes the ClimaRad control unit will take over and resume venting as appropriate e Start Pause press the pause button once The ClimaRad will pause for 60 minutes e End Pause after 60 minutes the ClimaRad will automatically end the pause To end the pause immediately press the pause button again 11 12 Functions Sensotronic Boost If you want to get rid of nasty smells or cigarette smoke you can run the ClimaRad fans temporarily on maximum speed using the boost button After 30 minutes the ClimaRad automatically returns to sensor controlled mode and vent accordingly e Boost on press the boost button The ClimaRad will run both its fans at maximum speed for 30 minutes
15. ee of pollution compare picture on previous page 1 Cleaning the air exhaust filter Regularly remove dust and other dirt particles in front of the exhaust filter with a vacuum cleaner to guarantee free passage of the room air To do this you do not have to remove the filter see illustration When the filter colour is dark grey almost black it is better to replace it because at that stage fine dust particles might pollute the heat exchanger and affect its performance 2 Release the filter holder security First switch off the ClimaRad using the main switch at the lower bottom The filter holder of the exhaust filter is secured with 2 screws that need to be removed The filter holder still stays in place because of 2 clamps that are positioned behind the screws 3 Tilt the filter frame Unclip the two clamps by gently pulling them forward The filter frame will tilt upward It stays hinged at the top There is no need to dismount the filter frame completely 21 22 4 Replace the filter elements The exhaust filter consists of three separate filter elements each positioned in their own frame within the filter holder While keeping the filter holder tilted upwards press on each old filter frame to remove it from its frame And put a new filter element back in 5 Closing the filter holder Tilt the filter holder downwards until the two clamps snap
16. g for cleaning The control of the ClimRad radiator is identical to what you are familiar with a normal or a thermostatic valve And should the situation require there is no problem to install even motor valves Intake of fresh air Inflow of filtered and pre heated fresh air Exhaust of used air Exhaust of used polluted air ClimaRad balanced ventilation unit The ventilation unit is located behind the radiator and consists of two maintenance free DC fans for air intake and exhaust a plastic heat exchanger air filters and an electronic control unit all this in a sturdy plastic housing Three types of ClimaRad balanced ventilation units are available e The Sensotronic features CO and humidity sensors continuously measuring the air quality The ventilation rate is PID controlled on the basis of the desired air quality level The user sets the desired air quality level through the control panel e The Slave Unit has no sensor no central processing unit and no control panel en must always receive its settings from a Sensotronic version Air Filters Every ClimaRad has a HAF High Air Flow air filters for the air intake and the exhaust air At the air intake side the filter cleans the incoming fresh air Used air from the room is also passed through a filter to keep the ClimaRad heat exchanger clean An light on the control panel indicates when the air intake filter needs inspection The filter for
17. l perform a self test during the first seconds Note the ventilation unit must always remain switched on It may only be switched off during servicing and maintenance 10 Functions Sensotronic Control panel See the illustration of the control panel on the inside cover The Sensotronic control panel allows the setting of the following parameters eDesired air quality eBase ventilation on off ePause button max 60 minutes fans off eBoost button max 30 minutes at max rate eNight cooling button max 6 hours Also the panel has indicator lights for eFilter inspection and eMalfunction Setting Desired Air Quality The Sensotronic default setting is sensor controlled which means that the unit is automatically trying to realize the desired air quality level With the help of the increase air quality and allow lower air quality you can set the desired air quality The scale of the 5 indicator lights on the control panel of the Sensotronic corresponds to the following CO2 concentrations lower CO2 levels mean higher air quality level 1600 1400 1200 ppm ppm ppm 1000 800 ppm ppm CO concentration e Increase air quality press the button until the desired air quality is reached button until the desired air quality is reached o e Decrease air quality press the Functions Sensotronic Base Ventilation By switching the base ventilation on you make sur
18. n fresh air for many years to come This manual tells you why a good indoor climate 1s important and how ClimaRad will help you to create it The manual shows you how to control and maintain the ClimaRad and provides a small troubleshooting guide Finally together with a copy of your invoice this manual is a necessary document for your warranty Therefore keep it in a safe place To get the most of your ClimaRad and to operate the unit safely we recommend that you read this manual carefully We are confident that you will be very satisfied with your purchase of the ClimaRad On behalf ofthe management ClimaRad Contents 1 Why ClimaRad ventilation 2 2 How does the Climakad WOFK ix xd 93 943 5 ew a 5 a MAGHOR 25 udin js tus d oa S94 aa arca HC Bea 8 4 Operating instructions ln 9 durae PTT 18 6 Irouble SNOOUING s as rip aaa eee 8 aa es 3 25 Technical specifications lll 28 Why ClimaRad ventilation Ventilations is a pure necessity Unfortunately some people tend to forget Insufficient ventilation can cause serious damage in a building Fungi and woodrot can cause permanent deterioration of the construction In the Netherlands alone this type of damage accounts for many tenths of millions of Euro Allergenic and hazardous substances in too high concentrations are perhaps an even more serious threat with severe consequences for your health
19. nd pollen filter and e a combi filter for fine dust with an additional active coal filter Energy Use and ClimaRad By far the most popular way of ventilation is opening windows and ventilation grids A considerable drawback of this method is that it is unpredictable whether the ventilation is too little unnecessary or just enough On top of that the warm indoor air is lost before its heat content energy being put to good use This energy waste is not only bad for your wallet but also for the environment ClimaRad has an air to air heat exchanger that transfers the heat of the outgoing air to the ingoing cold air This saves a bundle on your heating costs but also the ClimaRad is especially equipped to perform its function with a minimum consumption of electricity It uses DC fans in combination with a highly efficient power supply At a ventilation rate of 40 m per hour the electricity consumption is as low as 7 W At 80 m3 h it is a mere 25 W The stand by power use fans off but sensors still working is as low as 1 5W ClimaRad Energy Saving and Healthy ClimaRad has solved the dilemma A healthy indoor climate and saving energy at the same time is possible Any dwelling with at least one outside wall can have an optimal indoor air quality You set the desired level of air quality and the intelligent Sensotronic automatically takes care of the rest If you leave the room the ClimaRad Sensotronic detects the decreased CO
20. nique possibilities for installation For instance in older existing homes and buildings you can start installing one ClimaRad in a room with critical air quality e g a children s bedroom and then expand the system gradually to other rooms in the house Also in new houses and commercial buildings the fact that you don t need an in house duct system offers big advantages like lower installation costs appropriate ventilation per room and ease of maintenance To optimise the energy saving potential of the ClimaRad it is recommended to use the ClimaRad units in the rooms and combine them with discontinuous extraction fans in the wet areas of the house shower toilet Discontinuous means for instance timer or humidity controlled After the installation the installer is also responsible for testing en preparation for first use of the ClimaRad Operating Instructions 4 Instructions for first use Check if the power supply cord is correctly connected to a grounded wall socket 230V 50 Hz The control panel allows you to check and alter the ventilation settings Check whether the control panel is properly connected The ClimaRad also works without a control panel but in that case settings cannot be checked or altered Switching on You turn on the ClimaRad by switching on the on off switch at the left lower bottom of the ventilation unit The control panel indicators will light up and the electronics wil
21. ooling mode Functions Sensotronic Switch to manual operation The Sensotronic automatically controls the ventilation rate on the basis of input from the sensors and the desired air quality settings Should you for whatever reason prefer to temporarily switch to manual operation please follow these instructions e Switch to manual operation simultaneously press E A TEE aki the on pause boost and Cool Air buttons for 4 DM M te seconds The word luchtkwaliteit air quality will INTELLIGENT CO HUMIDITY CONTROL disappear A hand symbol and the word snelheid speed will now light up E luchtkwaliteit sensorgestuurd e Switch back to sensor controlled operation simultaneously press again during 4 seconds the on pause boost and Cool Air buttons The hand symbol and the word snelheid speed will disappear handbediening handbediening 13 14 Functions Sensotronic Adjusting the ventilation rate In manual mode the ClimaRad will operate on the first ventilation rate setting by default This first setting equals to a rate of 20 m3 hr By using the raise air quality and lower air quality keys you can adjust the indoor air quailiy The scale of five lights on the control panel shows the ventilation rate ranging from 20 m3 hr to 100m3 hr ventilation capacity 20 40 60 80 100 in m3 hr e Raise ventilation capacity press the key un
22. t on off Turning on off As a default factory setting the backlight of the control panel is turned on But it is also possible to turn the backlight off completely if a continuously lit panel is not desired In this turned off mode it is still possible to activate the backlight to check the settings by pressing a button any buttonbriefly The backlight will stay on for one minute after the last button is pressed and then returns to its turned off mode sensorgestuurd e Turn off the backlight simultaneously press the and the pause button until the last light on the left hand side of the indicator scale is turned off The ir o o backlight will now be turned off after 1 minute luchtkwaliteit sensorgestuurd e Turn on the backlight simultaneously press the and pause button until the desired luminance level is reached see also set backlight luminance handbediening o 0 maximum koele lucht handbediening O O O O O maximum koele lucht Indicators Sensotronic Filter polluted e After about 125 000 m3 of air has passed the filter factory setting a text saying filter vervuild filter polluted will light up to prompt you to check the pollution level of the air intake filter M gt filter vervuild Y N This indication does not influence the functionality of the ClimaRad It is merely intended to make you aware of a possible pollution of the filter For inspe
23. te You can influence this by setting a lower desired air quality This will cause the ClimaRad to turn down its flow rate after a while Also you can press the pause button to stop the fans from running for 60 minutes irrespectively of the air quality 26 The ClimaRad control panel doesn t react to pushing buttons v The control panel is locked the Lock indicator is lit Unlock the control panel see appropriate chapter v The wire between control panel and ClimaRad is damaged or the connectors to both are faulty Check and correct v There is a technical malfunction Please contact a qualified ClimaRad installer The ClimaRad doesn t react to nasty smells v The Sensotronic sensors just register CO and humidity levels A nasty smell in itself will not trigger ventilation If you want to vent the room use the boost button I hear an unfamiliar noise coming from the ClimaRad ventilation unit v The air ducts are polluted Inspect and clean v The noise is caused by an off balance fan Please contact a qualified ClimaRad installer It is difficult to tilt the ClimaRad radiator forward v The weight of a ClimaRad radiator tilting forward is compensated by a patented construction in the radiator supports to ensure safe and easy tilting action Turn the appropriate bolts in the radiator supports see illustration on the right counter clockwise to lower the compensation energy The ClimaRad
24. te operation and efficiency of the heat exchanger also on the long run It filters dust and dirt particles from the air going out of the room It is important to inspect these filters regularly and if needed replace them It is not possible to prescribe a standard period for inspection and or filter replacement It very much depends on the outdoor air quality in the area and the way the ClimaRad is used Brugman advices a filter inspection at least every 3 months If it turns out that the pollution level is low the frequency of filter inspection can be lowered In all cases the filters should be inspected at least every 6 months Inspection replacement of the air intake filter 1 Accessing the filter holder A Tilt the radiator forward and remove the metal dust cover on top of the ventilation unit Unclip the three blue clamps on top of the ventilation unit 1 This allows the filter holder 2 to be tilted forward First switch off the ClimaRad using the main switch at lower bottom of the device 2 Visible filter inspection Looking from the sides of the filter holder the colour of the filter can be checked The original color is white A light gray color indicates some pollution When the color is dark gray or black replacement is highly recommended 3 Filter replacement The filter consists of two parts that can be removed by the filter parts pulling sideways Remove any packaging from the new filter p
25. the outgoing air needs some regular cleaning with a vacuum cleaner from the outside no need to dismount the filter In principle this filter can be replaced Both the intake and exhaust filters can be easily exchanged by the user and require no special tools see chapter Maintenance Energy Saving The ClimaRad is a balanced ventilation system with waste heat recovery Balanced implies that per time period the amount of air that is extracted from the room equals the amount of fresh air Waste heat recovery means that the heat of the used exhaust air is used as much as possible to preheat the incoming fresh air This saves on your energy costs and prevents cold draughts from the incoming fresh air The automatic control of the ClimaRad Sensotronic also saves energy because no unnecessary ventilation occurs Finally the DC fans the efficient power supply and the low stand by consumption contribute to minimal electricity consumption see technical specifications for typical use data 3 Installation Your ClimaRad needs to be installed by a qualified ClimaRad installer who also has taken the additional ClimaRad installation training Only in that way an optimal operation of your ClimaRad can be guaranteed Note The power cord should only be replaced by qualified personnel This product needs to be connected to a grounded wall socket 230V 50 Hz Because ClimaRad requires no in house system of air ducts it offers u
26. til you have reached the desired setting e Lower ventilation capacity press the key until you have reached the desired setting Special functions Sensotronic Lock control panel Child lock The control panel can be locked so the pressing of any button has no effect luchtkwaliteit sensorgestuurd handbediening e Lock control simultaneously press on the pause maximum and Cool Air button for 4 seconds The Lock symbol will light up INTELLIGENT CO HUMIDITY CONTROL e Unlock control simultaneously press on the pause ore sensorgestuurd handbediening maximum and Cool Air button again for 4 seconds The Lock symbol will diappear INTELLIGENT CO HUMIDITY CONTROL Set backlight luminance The luminance of the control panel s backlight can be set You can choose between 5 luminance levels using the and buttons e Increase luminance simultaneously press the pause iratos sensorgestuurd handbediening and button until the desired luminance level is nb reached The scale with the 5 LED lights indicates the EUM SERIA O luminance level i e Decrease luminance simultaneously press the pause and button until the desired luminance level O is reached The scale with the 5 LED lights indicates the luminance level in luchtkwaliteit sensorgestuurd handbediening J O eo Oo 6 19 143 i koele lucht D 15 16 Special functions Sensotronic Turn the backligh