USER'S MANUAL - Gorke Electronic
Contents
1. 43 200 Pszczyna ul Staromiejska 31b tel 032 326 30 70 fax 032 447 73 30 www gorke com pl e mail biuro gorke com pl USER S MANUAL type of the device 4 channel 1000m set contains of IDO 500 identifying receiver and 4 key RNB 101S sender TABLE OF RANGE TECHNICAL PARAMETERS type of receiving module superheterodyne sensitivity 115 dBm frequency 433 92 MHz radio transmission KeeLoq hopping code by Microchip Technology memory capacity 500 supply 12 V AC DC or 24 V AC DC power consumption static 40 mA for 12 V DC maximal 150 mA for V DC capacity relay output NO 10A 230 V DC number of relays 4 relay s operating mode mono bistable or temporary time scope for the mono mode 1s 4min20s level of security IP 65 operating temperature range 20 to 40 C antenna socket BNC 50 Ohm dimensions mm 130 130 35 cooperation any GE sender cable output 3xPG 9 gland operating range m 200 1000 the range depends on the type of the sender 200 metres types of the remote controls PUK 101 PUK 102 PUK 104 PUK 112 1 PUK 112 2 400 metres PNH 201 hermetic button 600 metres PUK 303 remote control 1000 metres types of the remote controls RNB 101 RNB 1015 and NRP 100 stationary sender The above range concerns the open space without any obstacles when the receiver and the remote control can see each other If there are any obstacles between the receiver and the sender one must as
2. consists of several options LEARN DELETE OPERATING MODES EDIT TIME QUIT You can move in the main menu using the arrow up and arrow down buttons For example in order to enter the DELETE option you need to select DELETE on the display and press YES If you want to exit the programming mode and go to OPERATING mode you need to choose QUIT in the main menu and press the YES button On leaving the programming menu the device saves the current settings They will be saved also if there is lack of supply 2 LEARN OPTION it is used to enter the remote controls into the receiver s memory When you enter the LEARN option on the display you will see FREE 0004 which means that the first free cell is the cell number 4 After a few seconds the message will change into PRESS THE CONTROL the receiver is waiting for the signal from the remote control which is supposed to be entered into the receiver s memory under a number chosen before 4 Now press any button of the remote control being entered The receiver confirms the receipt of the signal with a long acoustic signal and after saving it moves to the main menu On the display you can see the message LEARN To enter the next pilot press the YES button and follow the above procedure The remote controls can be entered only to the subsequent cells If for example 200 remote controls were entered to the memory and the control number 130 had to be removed for example because it was lost t
3. be done h mi s You can increase or decrease the values on the particular positions can be performed with the and buttons You can move between the positions using the arrow up and down buttons After setting time for the relay 1 press the YES button which will move you to the time edition of the relay 2 If there is no need to change the settings of the presently displayed relay press the YES button After you finish editing the time for the relay 4 the receiver will move to the TIME EDIT option in the main menu 6 QUIT OPTION is used to quit the programming mode In order to finish the programming and move to the operating mode choose QUIT option and press YES SAVE SETUP will appear on the display it informs about saving the present settings to in the memory and than you will see READY text which confirms that the receiver is in the operating mode Gorke Electronic User s manual 1000 m 4 channel set page 3 43 200 Pszczyna ul Staromiejska 31b tel 032 326 30 70 fax 032 447 73 30 www gorke com pl e mail biuro gorke com pl SPECI FICATION Device a 9 button RNB 101S remote control TECHNICAL PARAMETERS class C frequency 433 92 MHz transmission coded KeeLog hopping code by Microchip Technology number of buttons 9 sending power lt 10mW power supply 1 battery 9V GF22 battery life 20 000 transmissions transmission length 0 5s antenna socket BNC 50 Ohm dimensions mm 65 100 24 colour
4. black cooperation any GE receiver operating range m with superreactive receiver 500 with heterodyne receiver 1000 The above range concerns the open space without any obstacles when the receiver and the remote control can see each other If there are any obstacles between the receiver and the sender one must assume that the range would be reduced for wood and plaster it would be 5 20 lower for bricks 20 40 lower and for reinforced concrete 40 80 lower If there are many obstacles we advise to configure the sets using the receivers of the SH class to use retransmitters or stronger remote controls If there are metal obstacles using the radio systems is not recommended In such situation consider installing WLC 201 module which helps to avoid the problem The 9 button RNB 101S remote control is used in such installations where a long operating range is required For users like security agencies army or police the control s main advantage is its solid construction It can be used as a unit which controls remotely the work of a wide variety of devices gates and garage doors barriers blinds electromagnetic locks lights pomps air conditioning etc In alarm systems it is used asa panic button to turn on off the zone etc as a unit which controls the work of other devices of the system for example sensors The transmission is based on the hopping code KeeLoq by Microchip Technology Inc USA which g
5. hen while entering the LEARN option first you have to save the control under the number 130 and only then under the number 201 In case of entering the same remote control twice the receiver does not report an error For example the remote control was entered under the numbers 12 and 34 so during the reception of signals from this control you will always see on the display the number of the earlier cell here 12 You should remove one of the records 12 or 34 If during entering a new control you wish to abort press the MENU button shortly when the message PRESS THE CONTROL is shown It will cause moving to the main menu Gorke Electronic User s manual 1000 m 4 channel set page 2 In order to avoid entering an accidental remote control into the receiver s memory it is recommended to disconnect the antenna for the time of learning 3 DELETE OPTION it is used to delete the remote controls from the receiver s memory After entering the DELETE option on the display you will see a message REMOTE CONTROL 1 If you want to delete the control which was saved in the cell number 23 set the required number on the display using the and buttons and then press the YES button The display will show a message DELETE 23 If you want to delete the chosen remote control press YES and you will see a message DELETING 23 and then the receiver will move to the DELETE option in the main menu If you want to abort the deleting or choose other con
6. of the relay to the other one by pressing another button After entering the OPERATION MODES option you will see a message in the display PK1 TIMER which means that the relay 1 is set on the timer mode You can change the operating mode by pressing the arrow down button On the display you will see in turn MONOSTABLE BISTABLE TIMER After choosing the right operating mode press the YES button which will move you to choosing the operating mode for the relay 2 If there is no need to change the operating mode press the YES button After confirming the operating mode for the relay 4 you will see on the display the message OPERATING MODES which allows you to move to another option in the main menu 5 TIME EDIT OPTION it allows you to set time for the relays which work on the timer mode If the timer mode is chosen in the option OPERATING MODES the relay s operating time will be specified by the settings in the TIME EDIT option The time setting done here has influence upon the operating only of those relays which work in the timer mode If they work in the mono or the bistable mode the time settings are not analyzed which means that they can have any value When you enter the TIME EDIT option you will see on the display the following message PK1 00 00 00 which tells you about the operating time for the relay 1 You can set the time in the value between 1s up to 99h 59 min 59 s The pulsing cursor shows on which positions the changes can
7. sume that the range would be reduced for wood and plaster it would be 5 20 lower for bricks 20 40 lower and for reinforced concrete 40 80 lower If there are many obstacles we advise to configure the sets using the receivers of the SH class to use retransmitters or stronger remote controls If there are metal obstacles using the radio systems is not recommended In such situation consider installing WLC 201 module which helps to avoid the problem The device meets the requirements of the directives EMC 89 336 EEC Gorke Electronic User s manual 1000 m 4 channel set and RTTE 1999 5 EC page 1 The receiver s use IDO 500 is used in various types of devices remote controlling when the superior parameter is either distinguishing the signal s source or the large memory capacity 500 It is also often chosen because of the possibility of deleting the senders individually from the receiver s memory In systems containing a dozen or several dozen remote controls using the relay receivers like RSU or OPC is very uncomfortable in case of deleting one or several controls The perfect solution in such situation is a receiver with an option of individual deleting like IDO 500 The receiver s operating after being connected to the supply the receiver launches test procedures When they are finished on the display you will see a message READY In the OPERATING mode the device receives the radio signals and after recei
8. trol s number answer NO to the question DELETE 23 It will move you to the DELETE option in the main menu Pressing the or buttons while choosing the control s number will make the receiver emit a sound signal which is supposed to warn against an accidental control s deletion 4 OPERATING MODE OPTION is used to set in which mode the individual relays should work Each of the relays can work on any of the following modes e the monostable mode timer each button press opens the relay for a set time range 1s 99h 59min 59s If the relay is open and you press the button on the remote control which controls this relay the countdown will start from the beginning e the monostable mode with the possibility of earlier closing e the temporary mode the relay is open as long as the control s button is pressed If you press it shortly it will make the relay work for 3 seconds e the bistable mode flip flop each button press makes the relay flip on the other state e two button mode using one button you open the relay with other button you close it It is possible to configure one relay on several modes For example you can combine the bistable mode with the monostable one The following effect will occur the remote control button 1 will turn the relay into the mono mode the relay will open and will stay this way for the time which was pre configured for this mode and then it will close In every moment you can change the state
9. uarantees high safety of using and resistance to the radio signals from other devices Each sender has its own individual code The receiver reacts only to the transmissions coming form the senders which have previously been entered into its memory Loosing 15 successive transmissions using the remote control beyond the receiver s range requires pressing the remote control button twice We are producing a RNB 101S sender with 2 3 4 5 6 7 8 9 keys as you wish The remote control does not signal the low battery level If the diode does not light when pressing buttons or if the range of the system decreased significantly it may indicate the need to change the battery Only when the remote control cooperates with the IDO 04 99 receiver the low battery level is signalled by the receiver The device meets the requirements of the directives EMC 89 336 EEC and RTTE 1999 5 EC Gorke Electronic Specification 1 key RNB 101 remote control strona 1
10. ving a right transmission it controls the relays according to the settings On the display a message will appear KEY 3 PILOT 14 which means that key 3 was pressed on the remote control saved in the receiver s memory under the number 14 Simultaneously it generates a short sound signal from the internal signalling device The message on the display remains until the next right transmission is received If the relay receives a signal from a remote control which has not been entered into the receiver s memory the message on the display will not change Instead a long sound signal is generated The switch should be set in the 12V or 24V position depending on the value of the supply voltage With the potentiometer CONTRAST you can set the contrast of the display The buttons of the remote controls were assigned to the relays permanently button 1 controls the relay number1 button 2 controls the relay number 2 etc If you use a one button remote control you will be able to control only the relay number 1 Only a 4 button remote control enables you to control all the relays The potentiometer CONTRAST is used to set the contrast on the LCD display The terminal strip SUPPLY is used to connect the power lead e NO C1 NC output of the relay 1 e NO C2 NC output of the relay 2 e NO C3 NC output of the relay 3 e NO C4 NC output of the relay 4 USER S MANUAL You can enter the programming mode by pressing the MENU button 1 MAIN MENU It
Download Pdf Manuals
Related Search
Related Contents
CG422/2010 - Instituto Nacional Electoral Live Cells.indd MiSeq FGx Instrument Reference Guide - Support Mode d`emploi - Leroy Merlin COMANDO REMOTO 4-CANAIS ZMP257/4 Diamond Shield Professional Instruction Manual Intel® Boot Loader Development Kit V2.0 Samsung ES80 Bruksanvisning Posizionamento di SB26 Copyright © All rights reserved.