        USER MANUAL
         Contents
1.                  eee eee acca 50    4 User Manual SATEL       1  General    Thank you for choosing the product offered by the SATEL Company  Wishing you full  satisfaction with the choice you made  we are always ready to provide you with professional  assistance and information on our products     The SATEL Company is manufacturer of a broad range of devices dedicated for use in  security alarm systems  Further information is available on our website www satel eu or at  the points of sale offering our products     2  Technical reliability of the alarm system    The alarm system is built of technical devices  the performance of which has crucial effect on  the effectiveness of the facility protection  Components of the alarm system may be exposed  to various external factors  such as weather conditions  e g  outdoor sirens and  during  a storm  also other devices  as a result of atmospheric discharge which may cause harm to  electrical and telephone installations  or mechanical damage  Only a routine check of the  system operation makes it possible to maintain a high level of burglary protection    The control panel is provided with a number of safeguards and automatic diagnostic features  to test the system performance  Detection of irregularities is signaled by the T   LED on the  keypad  You should immediately respond to such a signal  and  if necessary  consult  the installer     It is necessary to periodically carry out a functional test of the alarm system  Check that th
2.          Fig  4  Partition keypads  INT S and INT SK keypads are shown without flaps         6 1 Description of partition keypads    6 1 1 LED indicators    LED Color Function description  ON     partition armed       ON or blinking     alarm or alarm memory       blinking     trouble or trouble memory             Table 4  Description of LEDs in partition keypads     Information on the armed status can be extinguished after the time period defined by  the installer     If the installer has enabled the GRADE 2 option       the  QM LED will not inform about the alarms     38 User Manual SATEL           blinking of the CALED means that there is a trouble in the system  some zones are  bypassed  or that there was an alarm     The    gt  and  M LEDs blinking alternately indicate that the system is waiting for the  second code during the two code arming   disarming     All LEDs blinking in turn indicate that there is no communication with the control panel     6 1 2 Keys  The keys enable authorization of the user by means of code and running of the functions  available from the partition keypad     In the INT SCR keypad  the button is additionally available  It controls the keypad OC  type output  the output is active  when the button is pressed      6 1 3 Built in proximity card reader    The INT SCR keypad has a built in reader which enables operation by means of proximity  cards  proximity tags or other 125 kHz passive transponders   The installer determines  if the  reader will
3.      allows to temporarily disable the expansion module  tamper supervision  In case of any problems with the expansion modules  report the fact  to the installer     Permanent service access     the option is available to the master user  administrator   If  enabled  the installer has permanent access to the alarm system  which  among other  things  enables the control panel to be programmed by using LCD keypad or DLOADX  program     Enabling PERMANENT SERVICE ACCESS option will clear the installer access time  programmed with the SERVICE ACCESS function  On the other hand  programming the  installer access time will disable the PERMANENT SERVICE ACCESS option     Service can edit     the option is available to the master user  administrator   If it is  enabled  the installer can add  edit and delete users in the administrator s object     Service arm disarm clear bypass     the option is available to the master user   administrator   If it is enabled  the installer can arm disarm the system  clear alarms  and bypass zones in the administrator object     Permanent DLOADX access     the option is available to the master user  administrator   If  it is enabled  the control panel can be programmed by means of the DLOADX program   irrespective of whether or not the installer has access to the alarm system     DloadX IP     enables programming the address of the computer  on which the DLOADX  program is installed  The address must be set if the control panel is to initiate  commu
4.     signaling of         starting the procedure of arming  there is exit delay in the partition  or arming  there is  no exit delay in the partition          disarming and or alarm clearing       turning output off     10 User Manual SATEL           disabling chime signal in the keypad  using the 8 key         toggling the display between the standby mode and the partition status presentation  mode  using the 9 key         exiting the function and returning to the menu after confirmation of the data entered   4 short beeps and 1 long beep     signaling of        turning output on        enabling chime signal in the keypad  using the 8 key        ending the function and exiting the user menu after confirmation of the data entered   1 long beep     signaling of        violated  bypassed zones when arming         fault of the vibration detector  10  24H VIBRATION type zone was not violated during the  vibration detector test run upon starting the arming procedure    2 long beeps     invalid code card  function not available or exiting the function without  confirmation of the data entered  e g  by using the   key    3 long beeps     unavailable function     Events signaled by sounds    Only installer selected events are signaled     Alarms are being signaled throughout the time programmed by the installer     5 short beeps     zone violation  CHIME      Long beep every 3 seconds  followed by a series of short beeps for 10 seconds  and 1 long beep     countdown of exit delay  if 
5.    5 9 Master users  administrators     The master users  administrators  can be added  edited and removed by the installer  There  can be 1 administrator in each object  The administrator has access to all partitions in the  object and also specifies how the system can be accessed by using the service code  Most of  the parameters which are defined for the ordinary user can be defined for the administrator   see  section USERS p  26      5 10 Zone bypassing    You can bypass   unbypass zones in the disarmed partitions  Violating a bypassed zone will  not trigger any alarm  Bypassing the zones is useful in case of damage or failure of the  detector connected to the zone  which results in malfunctioning of the alarm system  e g   triggering false alarms      Zone bypassing reduces the level of protection  Prior to arming  make sure that there  are no accidentally bypassed zones in the partition  which might allow an intruder to  get access to the protected area despite arming     If a zone is bypassed  call in the installer  service technician  immediately to repair the  defect     For security considerations  the installer may reduce the number of zones that the user  will be allowed to bypass     5 10 1 Zone inhibiting    The zones can be inhibited by the users having the ZONES BYPASSING right  The inhibited   zone will be bypassed until the partition to which the zone belongs is disarmed  or until the   zone is unbypassed by the user    1  Enter the code and confirm with th
6.    administrators to view events required by EN 50131 for Grade 2 is available    1  Enter the code and confirm with the  K key    2  Press the 5 key  Functions available in the EVENTS submenu will be displayed    3  Using the W key  scroll the menu until the GRADE2 function is found    4  Press the   key  The last Grade 2 required event which occurred in the system will be  displayed    5  Using the A key  scroll through the list of previous events     5 11 3 Viewing the selected events    1  Enter the code and confirm with the     key   2  Press in turn the 5 and 1 keys     3  When the SELECT EVENTS function is displayed  press the H key  The list of event types  will be displayed     4  Select which event types are to be displayed  see  section SELECTION FROM THE MULTIPLE   CHOICE LIST p  16      5  Press the   key  This will bring you back to the SELECTED submenu    6  Using the W key  scroll down the menu until you find the View function    7  Press the   key  The last one of the selected events which occurred in the system will be  displayed    8  Using the A key  scroll through the list of previous events     In addition to defining the event types to be displayed  the SELECT PART  function can  also be used to indicate the partitions to which the events are to refer     If the GRADE 2 option is enabled in the system  the installer or administrator can use  the VIEW GRADE2 function instead of the ViEw function  In such a case  the events  selected among those required 
7.   1 The installer can define the list of outputs by means of the keypad  ABAX CONFIRMAT   function  SERVICE MODE    STRUCTURE    HARDWARE    EXPANDERS    ABAX CONFIRMAT    or a computer with the DLOADX program   Keyfobs ABAX  window     15 Press the   key   16  Press the   key   17 When a prompt appears  asking you if the changes are to be saved  press the 1 key       Keyfobs are added to the master users  administrators  in the same way     5 8 7 Removing keyfob    1  When adding or editing a user  run the REM  RX KEY FoB   REM ABAX KEYFOB function   depending on which keyfob is to be removed   The appropriate function is only displayed  when a keyfob has already been assigned to the user    2  When the keyfob number and a prompt whether the keyfob is to be removed are  displayed  press the 1 key  You will be brought back to the list of functions for defining the  user parameters    3  Press the   key     4  When a prompt appears  asking you if the changes are to be saved  press the 1 key     SATEL INTEGRA 31       Removal of a keyfob will not erase its settings  dependences between the buttons  and zones  confirmation rules  etc    When added to the user  the new keyfob will have  the same settings as the deleted one     The installer can remove all keyfobs  including their settings  by means of the functions  available in the service mode  P STRUCTURE    HARDWARE  EXPANDERS    REM RX KEY  FOBS   REM ABAX KEYFOB      The administrators  keyfobs are removed in the same way  
8.   press the   key for approx  3 seconds    medical  auxiliary  alarm     press the    key for approx  3 seconds     26 User Manual SATEL       panic alarm     press the a key for approx  3 seconds  The installer defines whether the loud  panic alarm  setting off the loud alarm signal  or the silent panic alarm  without the loud  signal  will be triggered     5 8 Users    The users can be added  edited and removed by    e master user  administrator     e installer  if the SERV  CAN EDIT option is enabled by the administrator    e user  if granted the USERS EDITING right     The following data can be defined for the user     Code     a sequence of digits for authorization of the user when using keypads and code  locks  The control panel supports codes consisting of 4 to 8 characters  however the  installer can define the minimum length of the code     Telephone code     a sequence of digits for authorization of the user when using the  functions of telephone call answering and telephone control  see  section CALL ANSWERING  AND TELEPHONE CONTROL p  43      Partitions     partitions to which the user has access  i e  he is authorized to arm or disarm  them  clear alarms etc       Type     see  section USER TYPES p  27   User schedule     parameter for the SCHEDULED type code  see  section USER TYPES p  27      Validity time     parameter for the RENEWABLE  TEMPORARY or SCHEMATIC type codes  see   section USER TYPES p  27      Blocking time     parameter for the BLOCKING PARTITIO
9.  ABAX confirmation     if an ABAX system keyfob has been assigned to the user  it is  possible to determine the status of which outputs will be presented on the keyfob LEDs on  pressing any button    Name     individual user name     5 8 1 User types    The name as used in the keypad is shown in the square brackets  The description includes  only the codes  but the information provided below applies to all identifiers assigned to the  user    Normal     basic type of user    One time  Single      the user will get one time access    Renewable  Time renewable      the user has access to the system for a defined period of  time  The user validity time should be defined  Before the validity time expires  the control  panel will prompt the user to change the code  After the code has been changed  the  validity time will run from the beginning    Temporary  Time not renew       the user has access to the system for a defined period of  time  The user validity time should be defined  After the validity time expires  the user will  have no access to the system    Duress     code to be used in hold up and duress situations  Use it to trigger a silent alarm  and send the event code to the monitoring station     28 User Manual SATEL          Mono    output operating  Mono outputs      code for control of the MONO SWITCH type  outputs        Bi    output operating  Bi outputs      code for control of the BI SWITCH type outputs     Blocking partition  Part temp block       the code enabl
10.  Call again within three minutes  The call will be  answered by the control panel immediately     Establishing connection will be signaled by three short beeps     2  Enter the telephone code on the telephone keypad  4 short beeps and 1 long beep will  confirm that you have got access to the call answering function  If the entered code is  invalid  this will be signaled by the control panel by two long beeps     44 User Manual SATEL       If you make a mistake when entering the code  enter the 4 digits anyway  and when  the control panel signals that the code is wrong  enter the correct code     After entering three wrong codes  the control panel will hang up     In case of a single call  if        no code has been entered and the connection is terminated        an invalid code has been entered and the connection is terminated    the control panel will answer no calls for the next few minutes  It enables e g  a fax to  be connected after the control panel     3  Within up to 15 seconds  enter the 2 digit partition number  e g  01  07 or 15   The control  panel will inform you about the partition status by means of sound signals   3 short beeps     partition disarmed   4 short and 1 long beeps     partition armed   If no key is pressed on the phone for 15 seconds  the control panel will hang up    4  Upon pressing in turn the 0 and   keys on the telephone keypad  the control panel will  hang up     10 2 Telephone control    1  Get access to the phone call answering function  s
11.  be operated     Presenting the card is interpreted in the same way as entering the code and confirming with  the    key  Holding the card  for approx  3 seconds  is interpreted in the same way as  entering the code and confirming with the   key     6 1 4 Sound signaling    Beeps generated when operating    The installer can disable the sound signaling or replace it with blinking of the keys  backlight     1 short beep     pressing any digit key  confirmation that code has been entered or card has  been read    2 short beeps     acceptance of the first code during two code arming   disarming    3 short beeps     signaling of         starting the procedure of arming  there is exit delay in the partition  or arming  there is  no exit delay in the partition          disarming and or alarm clearing   4 short and 1 long beeps     confirmation that the function has been executed   3 pairs of short beeps     the user should change his her code   1 long beep     refusal to arm  there are violated zones in the partition or there is a trouble    2 long beeps     unknown code card   3 long beeps     unavailable function     Events signaled by sounds    Only installer selected events are signaled     Alarms are signaled for the time programmed by the installer     5 short beeps     zone violation  CHIME     Long beep every 3 seconds  followed by a series of short beeps for 10 seconds  and 1 long beep     countdown of exit delay  if the time is shorter than 10 seconds  only  the final seq
12.  list the zone which is to be isolated  or press 0 key   and enter the zone number      4  Press one of the digit keys 1 to 9 until the   symbol appears in the upper right hand  corner of the display     5  Repeat the steps 3 and 4 for the next zones which are to be isolated   6  Press the   key  A message will inform you that the zones are isolated   Having started the ISOLATE function  step 2   you can press the    or 4 key to switch    over the keypad to the graphic programming mode  see  section SELECTION FROM THE  MULTIPLE CHOICE LIST p  16      5 10 3 Unbypassing    The zones can be unbypassed by the users having the ZONES BYPASSING right  Proceed in  the same way as when inhibiting or isolating the zones  steps 1 3   but the   symbol must be  shown in the upper right hand corner of the display  if the zone is to be unbypassed upon  pressing the   key     5 11 Viewing the event log    The events viewing function  when started by the administrator or the ordinary user   provides no information about         panic alarms       alarms triggered using the DURESS type code     5 11 1 Viewing all events    1  Enter the code and confirm with the  K key    2  Press in turn the 5 and 2 keys  The last event which occurred in the system will be  displayed    3  Using the A key  scroll through the list of previous events     SATEL INTEGRA 33       5 11 2 Viewing the events required for Grade 2   If the GRADE 2 option is enabled in the system  the function allowing the installer and
13.  maximum 50 minutes  and press the   key     10  Define  whether violation of a zone is to be signaled by chime in the keypad  the signaling  will be enabled upon pressing any digit key     the ti symbol will be displayed    11 Press the   key  The zone test will start     UDO JE PR    Beginning of the zone test in any partition will start the test mode in all ABAX system  wireless devices which are used together with the control panel  the wireless detectors  will signal violations by means of LEDS      If any detectors with remote LED ONOFF function are connected to the control panel   you can switch on the LEDs in them for the test duration  the installer can configure  the control panel so that this will take place automatically at the beginning of the test      You can terminate the zone test before expiration of the programmed time  using the  FINISH TEST function  P TESTS    ZONE TEST    FINISH TEST   Up to 6 seconds can elapse  between starting the function to the actual end of the test  during this the FINISH TEST  function will be still available      12  Depending on the type of tested detector         magnetic contact     open and close the door or window protected by means of the  magnetic contact         motion detectors     pass in front of the detector       other detectors     follow the manufacturer s directions for the detector testing     13  Look through the test results  To do so  enter again the ZONES TEST submenu  see  steps  1 5  and start the VIEW RE
14.  messages sent to the telephone number from which the control  command was received     12  Operating the alarm system by means of keyfob    For the INTEGRA 128 WRL control panel or any other control panel to which the ACU 120   ACU 270  ACU 100  ACU 250  INT RX or INT RX S module is connected  you can control  the system using the keyfob  The user can have up to 2 keyfobs         bidirectional APT 100 keyfob     supported by the ABAX system  INTEGRA 128 WRL  control panel  ACU 120  ACU 270  ACU 100  firmware version 2 00 or newer  or  ACU 250 controller         433 MHz keyfob     supported by the INT RX or INT RX S module    One keyfob enables execution of up to 6 functions  For each keyfob  functions to be executed  upon pressing a button   combination of buttons  and for the APT 100 bi directional keyfobs  also information to be displayed on the keyfob LEDs  are individually assigned  see  section  ADDING KEYFOB p  29      46 User Manual SATEL       Fig  6  APT 100 keyfob  A     numeration of LEDs  B     numeration of keyfob buttons     Fig  8  MPT 300 keyfob  433 MHz keyfob   A     numeration of keyfob buttons  The button  designated with digit 6 corresponds to the combination of buttons 1 and 3 in other 433 MHz  keyfobs        SATEL INTEGRA 47       13  Manual update history    Firmware  version  2013 08 e Information on INT TSG keypad has been added  p  6    e Note about the user having SIMPLE USER right has been added  p  10    e List of user functions has been supplem
15.  or to cease the attempts to send the code until a next event occurs     SATEL INTEGRA 5       4  Authorization of users    Operation of the alarm system is possible after the user authorization  which allows the  control panel to verify that the user is authorized to perform the given operation  The  authorization can be done on the basis of     e code    e proximity card  125 kHz passive transponder  which can be in the form of card  tag  etc     e DALLAS iButton  chip     e keyfob     You can not assign the same identifier  code  proximity card  DALLAS iButton or  keyfob  to two users     For safety reasons  different people should not use the same identifier     The installer can configure the panel so that it will not accept codes that contain less  than three digits  e g  1111 or 1212  or consist of consecutive digits  3456      The installer may permit the use of certain functions without the need for user  authorization     Using an invalid code  proximity card or DALLAS iButton three times may       trigger an alarm       block the keypad   reader for 90 seconds     4 1 Authorization with two identifiers    The INT KLCDR and INT KLFR keypads and the INT SCR multifunction keypads have a  built in proximity card reader  The installer can configure these devices so that the user has  to use two identifiers for authorization  the code and the card  The function to be executed  after the authorization depends on the second identifier         code     whether it will be co
16.  user has  normally no access     Abort voice messaging     terminates the telephone messaging     The messaging can be cancelled automatically together with alarm clearing  The  messaging cancellation rules are defined by the installer    Arm     allows to arm the partitions accessible to the user from the given keypad    Arm  2 codes      allows to initiate arming of the partitions which require entering 2 codes     Disarm  2codes      allows to initiate disarming of the partitions which require entering 2  codes     Defer auto arming     available when auto arming delay countdown is running  It allows to  postpone by a programmed time period the auto arming of the partition in which the auto   arming delay countdown is running  Entering just zeros will block the auto arming function   until the next auto arming time      Set auto arming delay     available when the auto arming delay is programmed for at least  one partition and the auto arming delay countdown is not currently running in that partition   It allows to postpone by a programmed time period the auto arming of the partition     Arming mode     allows to select the arming mode which is to be used  the shortcut key is  shown in square brackets       0  full arming  to be used after everybody has left the protected area       1  full arming   bypasses  allows the users to stay in the protected area      the zones for  which the BYPASSED IF NO EXIT option is enabled by the installer will be bypassed      2  arming w
17. 3  5 11 4 Way of presenting events    33  5 12 Programming the partition timer secretes ete di ated cs eed dea eed CC 34  5 139 ZOnE TESUNY sai kd Z i R A ad Aaa RAA AAAA err tn 34  5 14 Outputs control o odda ALWE A O LG A dLa adi 35  5 14 1 Controlling the MONO SWITCH type of output           eee e 36  5 14 2 Controlling the BI SWITCH type of output        e 36  5 14 3 Controlling the REMOTE SWITCH type of outputs                              eeeee aaa aaaaaaaaaaei 36  5 14 4 Controlling the roller shutter outputs                      s sseeseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 36   6  Using the partition keypad                       eeeee ea aaa aaa aaa aaa aaa aaa aaa az aaa wawa aaa aaa aaazzaaaaewaaaa zza aaie 37  6 1 Description of partition keypaQS                            ee eee aaa aaa aaa aaa aaa aaa aaa aaaaaaeeea aaa iaa 37  6 1 1 CEED INEO EEEE AOC SOLEO SOC EEEE CREED 37   NL AR PN 38  6 1 3 Built in proximity Card reader                cccccccccseeeeeeeeeeeeeececeeeeeeseeeeeeeeeeeeeaeesseeeeeeess 38  6 14   So  nd Signaling eee eer O W RA O WO ee 38   6 2 Functions available from the partition keypad                    eeeeeeeeeaa aaa aaa aaa aaa aaa aaaaaaeaci 39   01 NCCU EEN 39  622   Codejf dana a A   ote ttt dO 39  6 23  OUIERGMINO Gai iR A R e R a ee eT 39  6 2 4    Triggering the alarm from keypad                 e asa eee 40  6 2 5 Silencing the alarm sound at the keypad                       eeeeeeee eee aaa aaa aiiaa 40  6 2 6  Code changing zaszal
18. 8  Using the V and A keys  select which zone is to be violated on pressing the 1 button in  the keyfob  you can also enter the zone number from the keypad   and then press the    key    9  Repeat the steps 7 and 8 for other buttons   combinations of buttons which are to be  used    10  Using the VW key  find the EVENTS  RX    EVENTS  ABAX  function in the list    11 Press the   key  The list of buttons   combinations of buttons will be displayed  In the  upper right hand corner of the display  an additional symbol is located    El     pressing the button   combination of buttons is written to the event log  default  setting        pressing the button   combination of buttons is not written to the event log    12  Define whether pressing the button   combination of buttons will be written to the event log   see  section SELECTION FROM THE MULTIPLE CHOICE LIST p  16   and then press the   key    13  For the APT 100  ABAX  keyfobs  use the V key to find the ABAX CONFIRMAT  function in  the list  and then press the   key    14 A list will be displayed showing the outputs which have been assigned by the installer for  confirmation  maximum 8   Select up to 3 of them  see  section SELECTION FROM THE  MULTIPLE CHOICE LIST p  16   Upon pressing any keyfob button  information on the status of  selected outputs will be presented on the keyfob LEDs for a few seconds  Thus you can  get confirmation that the function has been executed or information on the current status  of the system   
19. N          g      o  3       e    a     x  clo 5 x 5lo o  v   lt   lt    o              o          O O   O     NIOJOTIRIWIN                       ELS JETEJR      EESTI EE    Table 3  Characters available when entering names  The lower case letters are available  under the same keys  to change the letter case  press W key     Shown on the left side in the upper line of the display is information about the letter case    ABC  or  abc   it will be displayed after pressing any key and will be visible for a few seconds  after the last keystroke      The b key moves the cursor to the right  and the 4 key     to the left  The A key deletes the  character on the left side of the cursor     18 User Manual SATEL       5 3 5 Description of user functions    View cleared alarms     available  if the user did not view the violated zones after alarm  clearing  It allows to check which zones triggered the alarm  After completion of the  viewing  the function is no longer available     System reset     available to the installer  if the option REQUIRED SYSTEM RESET AFTER VERIFIED  ALARM is enabled  and a verified alarm took place  After occurrence of the verified alarm  it  is necessary to reset the system by means of this function  in order to make re arming  possible     Disarm     allows to disarm the partitions accessible to the user from the given keypad   Clear alarm     allows to silence the alarm     Clear other alarms     allows to silence the alarms from other objects  to which the
20. N type code  see  section USER TYPES  p  27    Rights     define which functions can be used by the user  The following rights  permissions   are available       Arming      Disarming      Disarm  when other user arm  Can alw disarm      if the user does not have this right   he she can only disarm the system if it was armed by him her      Partition alarm clearing  Alarm clearing       Object alarm clearing  Object al clr        Other objects alarm clearing  Other al clr        Telephone messaging canceling  V msg clearing       Auto arming defer  Arm deferring       First code for two codes partition  Enter 1st code       Second code for two codes partition  Enter 2nd code       Access temporary blocked partitions  Block p access       Change access code  Code changing       Users editing      Zones bypassing  Zones inhibit       Zone isolation  Zones isolate       Clock setting      Trouble state checking  Troubles view        Event log reviewing  Events viewing     SATEL INTEGRA 27           Detectors resetting  Zones resett         Options programming  Options chang         Access to menu TEST  Tests        Downloading starting  Downloading        Access to BI  amp  MONO outputs  Outs control        System state review in GUARDX  GuardX using        Resetting outputs  Clr latch outs        Simple user     having entered the code  confirmed with the   key  the user never  selects the partitions which are to be armed   disarmed  All partitions the user has  access will be 
21. RMING   DISARMING MENU  p  10   If only selected partitions are to be disarmed  DISARM SELECTED function   the  partitions should be selected in the same way as when arming the selected partitions     5 5 1 Alarm clearing without disarming    1  Enter the code and confirm with the  K key   2  Using the V key  scroll through the menu until the CLEAR ALARM function is found   3  Press the   key     5 6 Two code arming   disarming    If the partition is to be armed   disarmed with 2 codes  the user entering the first code must   1  Enter the code and confirm with the  K key     2  Scroll through the menu using the W key until the ARM  2 CODES    DISARM  2CODES   function is found     3  Press the   key  Proceed in the same way as for the full arming of selected partitions   steps 3 7     4  If the installer has not set the code validity at 60 seconds  specify the code validity and  confirm with the   key     Prior to expiration of the code validity  the user entering the second code must arm   disarm  the partition using the     e LCD keypad  see  section ARMING or DISARMING AND ALARM CLEARING    e partition keypad   code      e reader  read in of proximity card or DALLAS iButton      1 The installer can configure the alarm system so that the second code will have to be  entered on another LCD keypad  partition keypad  etc     5 7 Triggering the alarm from keypad   The installer can permit triggering alarms from the keypad  To trigger an alarm  do the  following    fire alarm   
22. S submenu       Press the   key    Using the    key  scroll through the menu until you find the PART  TIMERS function        Press the   key  The list of partitions will be displayed     Using the V and A keys  find in the list the partition for which the timer is to be  programmed       Press the   key    8  When the ACTIVE option is displayed  make sure it is enabled  the   2 symbol is displayed  next to the option   If it is not enabled  the   symbol is displayed next to the option   press  any digit key    9  Using the WV key  scroll through the menu until you find the TYPE function    10 Press the   key    11 Using the V and A keys  select the timer type   everyday     if the partition is to be armed   disarmed at the same time every day     weekly     if the partition is to be armed   disarmed at different times on different days of  the week    12 Press the   key    13 If you have selected the daily variant  the function will allow you at once to program the  arming time  and upon pressing the A or V key     the disarming time  Upon confirmation  with the   key  you will be brought back to the list of options and functions    14 If you have selected the weekly variant  you will be brought back to the list of options and  functions  where functions will appear to enable programming of the arming   disarming  time for each day of the week  in the same way as for daily timer      ONAWNN    N      Programming the value 99 99 means that the partition will not be armed   dis
23. SULTS function  You can scroll through the list of results  using  the A and V keys  Press the    or 4 key to switch over the display to the graphic mode   in which information is provided by means of symbols      zone was not violated       zone was violated     Pressing the    or 4 key in the graphic mode will display information on another set of  zones  see also description of the H7 LEDs  p  8    The test results can be deleted by means of the CLEAR RESULTS function     TESTS   gt  ZONES TEST    CLEAR RESULTS         5 14 Outputs control    1  Enter the code and confirm with the  K key     If permitted by the installer  the control function can be started without user  authorization  upon pressing in turn the 8 and   keys        36 User Manual SATEL       2  Press the 8 key  Depending on how the control panel has been configured by the installer         a group of outputs will be displayed     using the V and A keys  find the group which  includes an output  and then press the   key to display the list of outputs         the list of controllable outputs will be displayed at once     3  Using the V and A keys  find in the list the output whose status you want to change to  control the device connected to the output  The output status is presented by means of  symbols       output inactive  disabled    ik   output active  enabled      The output status can be presented according to the zone status  The displayed  symbols should then be interpreted as follows         zone n
24. SWITCH type outputs     3 pairs of short beeps     the user should change his her code   2 long beeps     unknown code card     SATEL INTEGRA 41       3 long beeps     activation the delay is impossible  the partition is disarmed or the delay has  already been started  or the function is unavailable     Additionally  the keypad can audibly signal the DELAY ACTIVATION TIME     7 3 Functions available from the entry keypad    Depending on the user type and authority level  keypad settings and alarm system status   entering the code and confirming it with the    or   key  presenting the proximity card  will  result in     e activating the delay in partition for 3  INTERIOR DELAYED type zones   e changing over the status of 25  BI SWITCH type outputs    e turning on the 24  MONO SWITCH type outputs    e guard round confirmation     8  Using the code lock    The basic task of the code lock is to execute the access control function  supervise a single  door      SATEL offers the following code locks   INT SZ   INT SZK     The code locks are available with keys backlight in various color versions  The color version  is indicated by an additional letter symbol included in the code lock designation  e g   INT SZ GR     green backlight  INT SZ BL     blue backlight      8 1 Description of code locks                            integra                                                                                                                Fig  5  Code locks        42 User Manual SA
25. Saged     USER  MANUAL    INTEGRA       Alarm Control Panels    SATEL sp  zo o    ul  Budowlanych 66  80 298 Gda  sk  POLAND   tel    48 58 320 94 00    infoQsatel pl  C 4 www satel eu       integra _u_en 10 14    WARNING    Before you start using the control panel  please read carefully this manual in order to avoid  mistakes that can lead to malfunction or even damage to the equipment     Changes  modifications or repairs not authorized by the manufacturer shall void your rights  under the warranty     The INTEGRA control panels should only be connected to the analog subscriber lines  In  case of changing the analog line to the digital one  it is necessary to contact the alarm  system installer     Pay special attention if the telephone line used by the control panel is frequently busy and or  failures are reported  concerning the line and or monitoring  Report such situations to the  alarm system installer immediately    To ensure adequate protection  the alarm security system must be in good working order   therefore SATEL recommends that it be regularly tested  The control panel is equipped with  a number of self diagnostic functions which  when properly configured by the installer  ensure  control over correct functioning of the system    The alarm security system cannot prevent burglary  assault or fire from happening  but it  guarantees that in case of emergency measures will be taken to reduce the possible damage   the alarm will be signaled optically and acousticall
26. TEL       8 1 1 LED indicators    Function description  ON     code lock is operated by the control panel       ON     door unlocked       blinking     door open             Table 5  Description of the code lock LEDs       All LEDs blinking in turn indicate that there is no communication with the control panel     8 1 2 Keys    The keys enable user authorization by means of a code and starting of the functions  available from the code lock     8 1 3 Sound signaling    Beeps generated when operating    The installer can disable the sound signaling or replace it by blinking of the keypad  backlight    1 short beep     pressing any digit key or confirmation that code has been entered    4 short and 1 long beeps     confirmation of door unlocking or execution of another function    2 long beeps     unknown code card    3 long beeps     unavailable function     Events signaled by sounds      Only installer selected events are signaled   5 short beeps     zone violation  CHIME    Very short beeps     door open too long     8 2 Functions available from code lock    Depending on the user type and authority level  as well as the code lock settings  entering  the code and confirming it with the   or   key will result in     e unlocking the door  activating the relay     e changing over the status of 25  BI SWITCH type outputs    e turning on the 24  MONO SWITCH type outputs    e guard round confirmation    e enabling temporary partition blocking    The installer can permit triggering a
27. UTTER UP output active  on     l    SHUTTER DOWN output active  on      Pressing the   or b key will display the cursor in the form of a horizontal line under the  output status symbol  Pressing the A key will turn on the SHUTTER UP type output  if both  outputs are inactive  or turn off the SHUTTER DOWN type output  if it is active   Pressing the V  key will turn on the SHUTTER DOWN type output  if both outputs are inactive  or turn off the  SHUTTER UP type output  if it is active   Irrespective of which output is currently active   pressing any digit key will turn the output off  When the control is finished  press the   or  lt   key to return to the list of outputs which can be controlled  the cursor under the symbol will  disappear      SATEL INTEGRA 37       6  Using the partition keypad    The main task of the partition keypad is to arm disarm one partition  Additionally  it offers a  number of other functions  including e g  the access control  supervision of a single door      SATEL offers the following partition keypads    INT S    INT SK    INT SCR  multifunction keypad  offering the partition keypad functionality      The keypads are available with keys backlight in various color versions  The color version is  indicated by an additional letter symbol included in the keypad designation  e g  INT S GR      green backlight  INT S BL     blue backlight      INT SCR             integra                                                                                     
28. a   6  5 1 Keypads description ua A A EA KOGA 6  5 1 1 LED US o a R Aa ZPA bwa EOE EEEE 6  5 1 2 LED indicators  RR R ORO OR ORO r peade Earn p r RCA AGFA A 8  5 1 3 BOS eb a R   E E O E ED ORDO ODZEW 9  5 1 4 Built in proximity card reader aaa akad dada Ewki dwa 9  5 1 5 Sound signaling sasa0 0250000044 0000000000 00000000 Ot 9   5 2   Code       arming   disarming menu                        eee een a aaa aa aaa aaa aaa anawa wwa 10  5 2 1 AMINA MENU ce OOOO OR OO A OOOO OOO 11  5 2 2 DEGMI  Y MAW zs oo G  R G  zd ai a GG a RR 11   5 3   8050  SZCZ dinz TNA NAN 11  5 3 1 FinciGN R Rao ooo O ARS RER reco or reo rr Erec RSCG 11  5 3 2 Starting FUNCIONS ee eaaa aa eaa aaraa iaaa pE apanar iaa pidan Eiga 15  5 3 3 MENUSNANEUE sisena ORA EZR   W 15  5 3 4 Entering data by means of the LCD keypad                   cccccccseeeeeeeeeeeeeeeeeeeeeeeees 16  5 3 5 Description of user functions wo Gola 18   o PANINI 262 ce oe eee E E E 23  5 4 1 Full arming without partition Sel CtION                cccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneeenee 23  5 4 2 Full arming the selected partitions                             eeeoeee aaa aaa aaa nana aa zaaaaanaaaaacannc   23  5 4 3 Arming in the Selected mode eseoisiecEEo Gods se se 24  544 OQUICKAMMINAG NOE ER O ee 24  5 4 5 Denial  of ann   asi RR ae RR OR GAR O GAR O RR 24  5 4 6 Failure of arming proc  dUO Z Ad wodo wo i 25  5 4 7 Shortening the exit delay time wss awzy abso S EEEE AE SEE EEEE EEE AES E EEEE 25   5 5 Disarming and alarm c
29. al 40   T  Usingtheentry keypad  a a Se GH a Se CH ae GC ae eet 40  7 1 LED indicators zzz R AA A Aa FO a Aa PO Pw PO A cans 40  T2  S6UMdSG  aiNjok    aa RR ARR AGA A GR A GR Ro 40  7 3 Functions available from the entry keypad                    eeeeeeee eee na 41  0     UEMgihe code l6CR abo ROEE ROGER EEE EEEE EEEE OEG 41  8 1 Description of code LOCKS OEG OE GOO 41  8 1 1 LED NMG NNN cake vee  eeereeacecerveesecee reas eueerececece EEEE 42   oe PEJS ee eer AA AO brie et EA 42  Gales   Sound Signaling ZE 42   8 2 Functions available from code lOCK                     ss eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 42  9  Confirming voice messaging                              eomeneeoeeeeeeeoeeueeeuee eee eee ee u ua eee eee eee auta aut CAGE CAGE 43  10  Call answering and telephone control                   a aasaasaa saa aaa aaa wana aaa aaa aa aaa ka AAAA AAAA AAAA 43  10 1 Answering phone Calls aaa O EEEE Ea ELA EEEE EEK 43  10 2 Telephone COMMON   2  16i ccccccccsssnsssasscssssccsenscsssssecteascenacsesssessensececosasasssseacecesscenosssosees 44  10 3 Audio alarm verification 3 siete eee Aiaka 44  ERRIRE only INTEGRA 128 W R ce teceeseneeseesessetessseceeseeees 45  12  Operating the alarm system by means of keyfob                  c  seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeenaes 45  13  Manual update history                         eee eee aaa aaa aaa aaa aaa aaa aaa aaa aaa zzaaaaaaa aaa aaazzzanac 47  14  Brief description of operating the system from keypad     
30. ar other al  clear alarm in other objects  Abort voice m  cancel telephone messaging  Arm arm selected partitions   Arm  2 codes  start two code arming   Disarm  2codes  start two code disarming   Defer auto arm postpone the auto arming   Set auto arm d  set auto arming postpone time  Arming mode select arming mode    Cancel 1st code cancel consent to two code arming disarming    12    User Manual SATEL       Change own code  Change tel code  Change prefix  Prefix normal  Prefix duress  Recall time  Users  New user  Code  Telephone code  Partitions  Type  Schedule  Existence time  Bypass time  Rights  Keypads etc   New prox  card  Rem  prox  card  New DALLAS  Remove DALLAS  New RX key fob  Rem  RX key fob  Button 1  Button 2  Button 3  Button 4  Button 1 and 2  Button 1 and 3  Events  RX   New ABAX keyfob  Rem ABAX keyfob  Button 1  Button 2  Button 3  Button 4  Button 5  Button 1 and 5  Events  ABAX   Confirm   ABAX   Name  Edit user   select user                 change own code  change own telephone code    set normally used prefix  set duress prefix  set time to remind of the need to change prefix    add new user   set code   set telephone code   assign partitions available to the user  select type of code   select time schedule   set code validity time   set bypass time   assign rights   assign modules available to the user   add proximity card   remove proximity card   add DALLAS iButton   remove DALLAS iButton   add 433 MHz keyfob   remove 433 MHz keyfob   assign functi
31. armed     15 After the arming time has been programmed  an additional function will be displayed   which allows you to define which arming mode will be activated by the given timer  By  default  the timer activates the full arming mode  If another arming mode is to be  activated  run this function  for the daily timer or individually for each day of the week   and  using the A and V keys  select another arming mode  Confirm  using the   key    16  Having programmed all parameters  press the   key     17 When a prompt appears  asking you if the changes are to be saved  press the 1 key     5 13 Zone testing    Within periodic inspections of the security alarm system  the detectors must be checked for  proper functioning  The zone testing function will allow you to do it without triggering the  reaction normally expected on violation  which is of particular importance in case of  permanently armed zones    1  Enter the code and confirm with the   key     2  Using the    key  scroll through the menu until you find the TESTS submenu     SATEL INTEGRA 35       Press the   key    Using the W key  scroll through the menu until you find the ZONES TEST submenu   Press the   key    When the New function is displayed  press the   key     Select whether burglary zones or fire and technical zones will be tested  and then press  the   key     8  Select the partitions in which zones will be tested  see  section SELECTION FROM THE  MULTIPLE CHOICE LIST p  16      9  Specify the test duration 
32. armed   disarmed        Administrator     the user has access to the menu functions which are reserved for the  administrator   Keypads etc      additional modules from which the user will be able to operate the system   proximity card arm disarm devices  partition keypads  code locks  reader expanders     Proximity cards   DALLAS chips     if the proximity card   DALLAS iButton reader is used in  the system  a proximity card   DALLAS iButton can be assigned to the user  which will  allow the user to operate the system by means of readers    Keyfobs     in case of the INTEGRA 128 WRL control panel or any other control panel to  which a module with keyfob support is connected  ACU 120  ACU 270  ACU 100   ACU 250  INT RX or INT RX S   a keyfob can be assigned to the user  which will allow to  operate the system remotely  The user may have up to 2 keyfobs  the APT 100  supported  by the ABAX system  and the 433 MHz  supported by the INT RX or INT RX S modules     Buttons     the button functions are available  if a keyfob has been assigned to the user  It is  possible to assign a zone to a keyfob button or combination of buttons  The zone will be  violated upon pressing the button   combination of buttons  The assigned zone should not  exist physically    Events  RX    Events  ABAX      if a keyfob has been assigned to the user  it is possible to  define whether pressing the appropriate keyfob button will result in logging an event which  informs that the keyfob has been used   
33. asters    New user  New master    Edit user  Edit master    Remove user  Remove master   Zone bypasses   Inhibit   Isolate   Events   Selected events   All events   Set time   System state   Outputs control   Service mode   Downloading   Start DWNL RS   Finish DWNL RS   Start DWNL MOD    Start DWNL TEL   Start DWNL CSD  INTEGRA 128 WRL   Start DWNL GPRS  INTEGRA 128 WRL   ETHM 1     DloadX   ETHM 1     GuardX       Ez   O  O          O    Ey    blinking     service mode started    1  group  numbers  1 32   addresses 00 1F   2  group  numbers  33 64   addresses 20 3F   3  group  numbers  65 96        4  group  numbers  97 128    LED OFF         LED ON    O      O                                                                 Q Q   9 Q      z g  LI  A e  3  ES  ls    34 5 10  Wie W m a noa s s a a 2 w a a    Satea  integra             1 2 mc   3der    k U    ka Z     gni    5 jk FA o0  ai     lt        Tpars   Biv   Gwaz      6  A i                                                                            Shortcut keys  press for approx  3 seconds    1     check zone status   4     check partition status   5     view alarm log   6     view trouble log   7     view current troubles    8     CHIME signal ON OFF   9     toggle display between standby mode and partition  status mode   O  trigger medical  aux  alarm         trigger fire alarm   O     trigger panic alarm       
34. bles exiting the function  without saving any changes     Described below are general rules for entering data  however they may be different as  regards some functions     Selection from the single choice list    Shown in the upper line of display is description of the function  and in the lower one     the  currently selected item  You can scroll through the list of items  using the direction keys  Y   down  and A  up   The    and 4 keys are not used     Selection from the multiple choice list    The functions that allow you to make multiple choice can be identified by an additional  o  situated at the right hand side of the display     l     displayed item is selected   option is enabled       displayed item is not selected   option is disabled     Pressing any digit key  for some functions  this does not work with the key O  will change the  currently displayed symbol to the other one  To scroll through the list of items  use the W key   down  or the A key  up   For some functions  pressing the key O will allow you to enter the  number of item to be edited  e g  number of zone to be bypassed   unbypassed   This will  speed up search    For some functions  pressing the b or 4 key will switch the keypad into the graphic  programming mode  The Hi and   symbols are used to present on the display the current  status of up to 32 items available in the given function     these can be e g  zones  outputs   timers  etc    Additionally  in case of zone bypassing  the i  symbol is us
35. by the EN 50131 standard for Grade 2 will be  displayed     5 11 4 Way of presenting events    The following information is shown in the display upper line        date and time of event occurrence        additional information on the events in shortened form  e g  number of partition  zone    user  timer  expander  keypad  etc    Event description is displayed in the lower line   If no key is pressed for a few seconds  additional information on the event will be displayed   e g  name of partition  zone  user  timer  expander  keypad  etc  After a few seconds  the  event description will be displayed again  and so on   Pressing the    key enables the manual toggling between description of the event and  additional information on the event   Pressing the 4 key when the event description is displayed will allow you to see further  additional information on the event  shown in a shortened form   Using the 4 or  gt  gt  key will block the automatic toggling between description of the event and  additional information on the event     34 User Manual SATEL       After the list of events has been scrolled through with the use of the A or W key  the  automatic toggling between description of the event and additional information on the event  will be restored     5 12 Programming the partition timer    The partition timer automatically arms   disarms the partition      Enter the code and confirm with the   key    Using the V key  scroll through the menu until you find the CHANGE OPTION
36. confirmed with the   key     5 4 1 Full arming without partition selection   The arming without partition selection is possible when none of the partitions to which the  user has access is armed and the keypad is not signaling any alarm    1  Enter the code and confirm with the   key     2  When the ARM ALL function is displayed  press the   key  The arming procedure will be  initiated in all partitions which are accessible to the user and are operated by the keypad     If the user can only arm one partition  the arming procedure will be initiated as soon as  the code is entered and confirmed with the   key     5 4 2 Full arming the selected partitions    1  Enter the code and confirm with the   key    2  Using the V key  scroll through the menu until you find the ARM function   3  Press the   key  A list of partitions which can be armed will be displayed   4      Using the V and A keys  find in the list the partition which is to be armed  or press 0 key  and enter the partition number      5  Press one of the digit keys 1 to 9  The   symbol in the upper right hand corner will be  replaced by the ii symbol  see also section SELECTION FROM THE MULTIPLE CHOICE LIST  p  16     6  Repeat the steps 4 and 5 for the next partitions which are to be armed    7  Having selected the partitions which are to be armed  press the   key     24 User Manual SATEL       You can also arm the selected partitions using of the ARM SELECTED function  available upon  entering the code and confirming 
37. e   key    2  Press in turn the 4 and 1 keys  The list of zones will be displayed  There is an additional  symbol in the upper right hand corner of the display to inform you about the given zone  status           the zone is not bypassed   kd     the zone is inhibited   IE     the zone is isolated   3  Using the V and A keys  find in the list the zone which is to be inhibited  or press 0 key  and enter the zone number    i    4  Press one of the digit keys 1 to 9 until the E  corner of the display     5  Repeat the steps 3 and 4 for the next zones which are to be inhibited     symbol appears in the upper right hand    32 User Manual SATEL       6  Press the   key  A message will inform you that the zones are inhibited     Having started the INHIBIT function  step 2   you can press the    or 4 key to switch  over the keypad to the graphic programming mode  see  section SELECTION FROM THE  MULTIPLE CHOICE LIST p  16      5 10 2 Zone isolating   The zones can be isolated by the users having the ZONES BYPASSING and ZONE ISOLATION   rights  The isolated zone will remain bypassed until unbypassed by the user    1  Enter the code and confirm with the  K key    2  Press in turn the 4 and 2 keys  The list of zones will be displayed  There is an additional  symbol in the upper right hand corner of the display to inform you about the given zone  status          the zone is not bypassed   id     the zone is inhibited   Ei     the zone is isolated    3  Using the V and A keys  find in the
38. e  control panel responds to violation of individual detectors  that their coverage areas are not  obstructed  that there is a reaction to opening protected windows  and that sirens and  telephone messaging work normally     Detailed instructions on the system testing should be provided by the installer  It is  recommended that the installer carry out periodic maintenance of the alarm system  when  ordered by the user     It is in the user s interest to foresee and prearrange the procedures to be followed when the  control panel signals an alarm condition  It is important to know how to verify the alarm and  identify its source on the basis of keypad information  and take appropriate measures  e g   to  organize evacuation     3  Alarm system operating costs    The control panel can inform the users and the monitoring station about the status of  protected facility  Realization of these functions by means of the phone line or GSM means  financial costs  The amount of the costs incurred depends on the amount of information sent   A failure of telephone links  as well as an incorrect programming of the control panel  may  result in increased costs  due to making of excessive number of calls      Please inform the installer  which is a priority  to deliver information at any cost  or to prevent  excessive costs  For example  after an event code has failed to be sent successfully to the  monitoring station  the control panel may repeat attempts every few minutes to send the code 
39. e has not been confirmed      If the control panel is sending messages about several events and confirmation of the  voice messages is required  each message should be confirmed  The first message  must be confirmed before the second message can be played back  an so on     The installer can configure the control panel so that acknowledgement of receiving the  message by the user will         clear messaging other users       allow to get access to the INT VG module voice menu     10  Call answering and telephone control    The information below does not apply to the control panels to which the INT VG  module is connected     The call answering and telephone control functions are available to the users who have the  telephone code  These functions require that the DTMF dialing phone be used  The call  answering function allows to get information on the partition status  armed  disarmed   Owing  to the telephone control function  it is possible to control the REMOTE SWITCH type outputs  using the telephone     10 1 Answering phone calls    1  Establish connection with the control panel  using one of the following methods  consult  the installer to learn which method is supported by the control panel    single call     call the telephone number of control panel  The control panel will answer the  call after the number of rings programmed by the installer   double call     call the telephone number of control panel  Hang up after the number of  rings programmed by the installer 
40. e operated by means of the SMS messages  containing suitable control commands  The content of commands and the additional rules of  how to use them  using the lower case and upper case letters  adding the telephone code to  the content of sent SMS message  etc   are to be defined by the installer  If appropriate  control commands are programmed by the installer  the SMS messages can be used to    e violate selected zones    e temporary bypass selected zones    e unbypass selected zones    e arm selected partitions in selected mode    e disarm selected partitions    e clear alarm in selected partitions    e activate selected MONO SWITCH type outputs    e activate selected BI SWITCH type outputs    e deactivate selected BI SWITCH type outputs    e toggle selected BI SWITCH type outputs    e check status of selected partitions     e send the USSD codes to the operator of SIM card installed in the module  e g  to check  the card account status or recharge it   The answer received from the operator is  forwarded in the form of SMS message to the telephone number from which the control  command was sent    When sending the USSD codes  the SMS message must have the following form    xxXXXX Vyyy     where  xxxxxx  is the control command and  yyyy  is the USSD code supported by the GSM  network operator     The SMS message may contain several control commands   If correctly programmed by the installer  the control panel will confirm execution of the control    commands by means of SMS
41. e selected digit  keys for approx  3 seconds  you can  if the keypad has been so configured by the installer      1   check the state of zones     check the state of partitions     view the alarm log     view the trouble log     view the current troubles     enable disable chime signal in the keypad     toggle the display between the standby mode and partition state display mode   The other keys enable you to       enter the user menu  after entering the code      cancel the started operation     COON OO R      or Ok   arm  disarm and clear alarm  after entering the code      start the selected function     confirm the entered data    lt A YP  navigate through the display  scroll through the displayed messages  functions  and options  and move the cursor      run the installer selected functions  after entering the code      cw   trigger the fire alarm   O   trigger the medical  auxiliary  alarm       trigger the panic alarm     5 1 4 Built in proximity card reader    The INT KLCDR and INT KLFR keypads can be operated by means of proximity cards   proximity tags or other 125 kHz passive transponders   The installer defines which functions  can be executed after presenting or holding the card     5 1 5 Sound signaling    Beeps generated when operating      The installer can disable the sound signaling     1 short beep     pressing any number key     2 short beeps     confirmation of command execution  signaling of entering the user menu   submenu or function     3 short beeps 
42. e user has been modified  Press the    key to return to  the list of users     ONOUNAW    5 8 4 Removing a user    1 The user can remove the users in relation to which he she is the superior  For  example  if the user A has created the user B  and the user B has created the user C   then the user A can remove the users B and C     Enter the code and confirm with the     key    Press in turn the 2 and 3 keys  The list of users will be displayed    Using the V and A keys  find in the list the user who is to be removed   Press the   key  A message will inform you that the user has been removed   Press the   key to return to the list of users      8 5 Adding proximity card   DALLAS iButton    When adding or editing a user  run the NEW PROX  CARD   NEW DALLAS function      Using the V and A keys  select how the card   iButton is to be added  The number of  card   iButton can be read by a selected reader  device equipped with a reader  or  entered manually    3  Press the   key    4  If the number of card   iButton is to be read  read in the card   iButton twice  following the  instructions appearing on the keypad display  When the read number of card   iButton is  displayed  press the   key    5  If the number of card   iButton is to be entered  enter it from the keypad  and then press  the   key    7  You will be brought back to the list of functions for defining the user parameters  Instead   of the NEW PROX  CARD   New DALLAS function  the REMOVE PROX  CARD   REMOVE   DALLAS fu
43. ed  The b key moves  the cursor to the right  and the 4 key to the left  If the list of items is longer than 32  pressing  the b key when the cursor is placed over the last item will display the next list  and pressing  the 4 key when the cursor is placed over the first item will display the previous list  see also    SATEL INTEGRA 17       description of the HS LEDs  p  8   Pressing the key 0  1 or 2 three times in the graphic mode  within 3 seconds will have the following effect     000   the   symbol will be displayed at all available items   111   the   2 symbol will be displayed at all available items   222   reversal of the selection made  the Li symbol will be displayed at all items where    the   symbol was displayed  and the   symbol where the  amp    symbol was displayed     Fig  3  Example of how information is presented in the graphic programming mode  The blank  fields are not available for editing        Entering decimal and hexadecimal values    Digits are entered by pressing the suitable keys  Characters from A to F are available under  the keys with numbers 2 and 3  Keep pressing the keys until the required character appears     Entering names    Press the particular keys until the required character appears  The characters  available in the keypad are shown in Table 3  Hold down the key to display the digit  assigned to the key               Characters available after next keystroke      per Tis  w sje t   lfe t 1                               WM  O O0O RIW 
44. ented  p  11    e Description of CHANGE TELEPHONE CODE user function has been added   p  18    e Description of SIMPLE USER right has been added  p  27    e Description of ADMINISTRATOR right has been added  p  27    e Information on maximum duration of zone testing has been modified  p  34    e Section  Audio alarm verification  has been added  p  44    e Information on the INT KLFR  p  5  6 and 9  and INT TSI  p  6  keypads has  been added   e Description of IP MAC ETHM 1 user function has been modified  p  22    Information on the ETHM 1 Plus module has been added   List of user functions has been supplemented  p  11      Note on the possibility to disable user menu shortcuts by the installer has  been added  p  15      Information on new functionality of the key 0 when editing the multiple   selection list in text mode has been added  p  16  23  31 and 32      e Description of GPRS MONIT TEST user function has been added  p  21      Introduced changes             14  Brief description of operating the system from keypad    r  A  blinking     trouble or trouble memory   Grade 2     trouble or trouble memory  bypassed zones or  alarm           ON     all partitions operated by the keypad are  armed  blinking     some partitions are armed    Quick arming    O    full arming   1    full arming   bypasses   2    arming without interior   3    arming without interior and without entry  delay     CODE  K     enter the user menu  User menu shortcuts     Change own code   Users  M
45. es access to the armed partitions   Using the code will block the armed partition s   the partition zones will not trigger the  burglary alarm   The blocking time is defined individually for each user within the range  from 1 to 109 minutes  If  however  the time of bypassing for guard round is defined for the  partition and its duration is longer  the blocking will last longer     Cash machine zones bypassing  Acces to cash m       the code to be used to unblock  access to the cash dispenser  the 24H CASH MACHINE type zones will be temporarily  bypassed in the partition     Guard     using this code means having made the round  additionally  it can result in the  partition being temporarily bypassed for the duration of guard round   The installer defines  the modules which are used to confirm making the round and determines the time interval  between successive rounds  If such a user is granted access to the partition  he she will  have the same possibilities as the NORMAL type user    Scheduled     the user has access to the system as per the time schedule for a specified  period of time  It is necessary to select the schedule  the schedule is programmed by the  installer  and define the user validity period     5 8 2 Adding new user    1  Enter the code and confirm with the   key   2  Press in turn the 2 and 1 keys  The list of functions to define the user parameters will be  displayed     1 If the service code has been entered  before the list of functions is displayed  i
46. es an event  which starts the procedure of event  transmission to the monitoring station  a code sent with the system identifier     Monitoring station test  1A  1B  2A  2B      allows to send a test transmission to the  monitoring station  separate functions for each of the telephone numbers   When  sending the transmission  messages are displayed to inform about the currently  performed operation  The function is useful when starting the reporting or in case of any  reporting trouble     GPRS monit test     sends a test transmission to the monitoring station via GPRS  When  sending the transmission  messages on the display provide information on the currently  performed operation    Messaging test     allows to test the messaging function  Upon starting the function    1  Enter the number of the telephone  consecutive number on the telephone list      2  Press the V key   3  Enter the number of voice message       a Es    22 User Manual SATEL       4  Press the H key  The control panel will call the indicated number and play back the  message    Answering test     if this function is started  information on the number of rings and going  off hook is displayed when answering the telephone call    Proximity card test     allows to check the number of proximity card and establish to whom  it belongs  if the card belongs to a user of the system     CA 64 PTSA test     allows to test the mimic board    View masters     available to the administrator  It makes it possible to chec
47. es place every day at 05 30     Service access     available to the master user  administrator   Allows to program the time  period of installer access to the alarm system  The time is programmed in hours   Programming the value 0 means the installer will have no access    Open door     allows to unlock the door controlled by the alarm system  modules executing  the access control functions  or activate the 101  CARD READ     EXPANDER type outputs    Outputs control     allow to control the devices connected to the MONO SWITCH  BI SWITCH   REMOTE SWITCH  SHUTTER UP and SHUTTER DOWN type outputs  see  section OUTPUTS  CONTROL p  35     Service mode     available to the installer  Initiates the service mode    Take SM over     available to the installer  If the service mode has been initiated from another  keypad  it can be  taken over   i e  the service menu can be displayed on the keypad  on  which the TAKE SM ovER function has been started    Downloading     the following functions are available in the submenu    Start DWNL RS     available to the installer  Enables the control panel to be programmed  locally by means of the DLOADX program    Finish DWNL RS     available to the installer  Ends the local programming of control panel    Start DWNL MOD      enables remote programming through an external modem  analog   GSM or ISDN  by means of the DLOADX program     SATEL INTEGRA 23       Start DWNL TEL     enables remote programming through the built in 300 bps modem   using t
48. est  Station 1A test  Station 1B test  Station 2A test  Station 2B test  GPRS monit test  Messaging test  Answering test  Prox  card test  CA 64 PTSA test  View masters                                           view events required for Grade 2   view all events   view events required for Grade 2   reset 43  RESETABLE POWER SUPPLY type outputs  clear latched outputs   end door fire opening    enable disable CHIME in keypad   block zone violation signal  on 11  CHIME type outputs  edit timers   program partition timers   block expander tampers   enable disable permanent installer access  make user editing available to installer   make system control available to installer  enable disable permanent DLOADX access   set address of computer with DLOADX program  set address of computer with GUARDX program  erase service note    check current state of partitions   check current state of zones   check module supply voltage   check radio signal level for wireless devices   check temperatures measured by ATD 100 detectors    start new test for burglary zones   start new test for fire and technical zones   view test results   abort test   clear test results   test battery and 60  TECHN    BATTERY LOW zones   start manual test transmission   start test transmission to station 1     main phone number  start test transmission to station 1     backup phone number  start test transmission to station 2     main phone number  start test transmission to station 2     backup phone number  send te
49. he DLOADX program     Start DWNL CSD     enables remote programming through the built in GSM communicator   using CSD technology  by means of the DLOADX program  fanciers IE    Start DWNL GPRS     enables remote programming through the built in GSM    communicator  using GPRS  General Packet Radio Service   by means of the DLOADX  program  ela nels i ZERWIE    ETHM 1     DloadX     enables remote programming through the Ethernet  TCP IP  by  means of the DLOADX program  The ETHM 1  firmware version 1 03 or newer     ETHM 1 Plus module must be connected to the control panel     ETHM 1     GuardX     enables remote operation and administration through the Ethernet   TCP IP  by means of the GUARDX program  The ETHM 1  firmware version 1 03 or  newer    ETHM 1 Plus module must be connected to the control panel      5 4 Arming    This section describes the operations that must be carried out by the user from the keypad in  order to initiate the arming procedure  The arming procedure is ended at the running out of  the exit delay time  if the procedure is ended successfully  the system becomes armed     see  also FAILURE OF ARMING PROCEDURE p  25   If the exit delay time is O  the system becomes  armed instantly     The installer can configure the alarm system so that the arming functions will not be  available after tamper  A message on the display will indicate that the user must call  for service  The arming functions will not be available until the service code is entered  and 
50. ithout interior  allows the users to stay in the protected area        interior zones  3  INTERIOR DELAYED zone type  will be disarmed       violating the exterior zone  8  EXTERIOR zone type  will trigger a silent alarm       violating another alarm zone will trigger a loud alarm     3  arming without interior and without entry delay  allows the users to stay in the  protected area     to be used when nobody else is to enter the protected area      this  arming mode is similar to the previous one  but the delayed zones operate as the  instant ones  no entry delay     Cancel 1st code     if the partition is armed disarmed by means of two codes and the first  code has already been entered  the user can still cancel the consent to arming disarming   Change own code     allows the user to change his her own code     Change telephone code     allows the user to change his her own telephone code     SATEL INTEGRA 19       Change prefix     available to the administrator  if the use of prefixes in the system has been  made available by the installer  the prefix length has been defined   It enables to program  the prefixes and the time to remind about the need to change the prefix  Each code will  have to be preceded by a prefix     normal     for everyday use  By default  it consists of a suitable number of digits O  e g  if  the determined prefix length is 4  the default prefix is 0000      DURESS     for use  when the user has been forced to enter the code  Using the code will  t
51. itions accessible to the user and  operated from the keypad  The zone status is presented by means of a symbol  The  numbers placed on the glass allow you to identify the zone numbers  On starting the  function  the status of zones 1 32 is displayed  Use the b and  lt  keys to display the  status of other zones  see also description of the HT LEDs  p  8   By factory default  the  zone status is shown using the following symbols  which can be changed by the  installer        zone bypass      trouble  long violation       trouble  no violation       tamper alarm    alarm      zone tamper      zone violation      tamper alarm memory    a   alarm memory     zone OK    Supply voltages     available to the installer  Enables checking of the supply voltage for  individual expansion modules    Temperatures     allows to check the temperatures measured by ATD 100 wireless  detectors    Radio devices     allows to check the radio signal level for ABAX system wireless devices  supported by the control panel    Zone Test     the submenu contains functions which allow to test the detectors connected  to the zones  see  section ZONE TESTING p  34     Battery test     available to the installer  Upon starting the function  the control panel will  generate events to inform about the status of batteries of the control panel and  hardwired expansion modules with power supply  Additionally  the status of 60  TECH    BATTERY LOW type zones will be analyzed    Manual transmission test     generat
52. k in which  objects the master users are created    Keypad name     allows to check the given keypad name     File in DLOADX     displays the date and time of writing the data to the control panel by  means of the DLOADX program and the name of file with control panel data     Panel version     displays information on the control panel firmware version    STM program version     displays information on the program version of the processor  used to operate ABAX system and control panel zones    GSM IMEl v sig      allows to check the level of signal received by the GSM telephone  antenna  individual identification number of the telephone  and the telephone version     The A and V keys are to be used for scrolling through the displayed information   INTEGRA 128 WRL    IP MAC ETHM 1     displays the local IP address  MAC number and public IP address of  the ETHM 1   ETHM 1 Plus module connected to the control panel  use the V and A  keys to scroll the information     Modules versions     allows to check the firmware versions for devices connected to the  control panel communication buses    Time synchronization     allows to manually start synchronization of the control panel  clock and the time server  It applies to the control panel to which the ETHM 1   ETHM 1  Plus module is connected  The address of time synchronization server must be  programmed in the control panel     The function is unavailable  if the time synchronization is running  Automatic time  synchronization tak
53. larms from the keypad  To trigger an alarm  do the  following    fire alarm     press the  INT SZ     INT SZK  key for approx  3 seconds    medical  auxiliary  alarm     press the 0 key for approx  3 seconds    panic alarm     press the  INT SZ     INT SZK  key for approx  3 seconds  The    installer defines whether the triggered alarm will be loud  setting off the loud alarm  signaling  or silent  without loud signaling      SATEL INTEGRA 43       The installer can permit changing own code by means of the code lock  Proceed in the same  way  as when changing the code by means of the partition keypad  see  p  40      9  Confirming voice messaging    The installer can configure the control panel so that confirmation of listening to the voice   message be required  If there is no confirmation  the control panel can connect many times   for playback of the message  Having listened to the message can be confirmed from the   keypad of DTMF dialing telephone  The installer defines whether any 4 digit sequence is   sufficient to confirm receipt of a voice message  or it must be a specific code  After entering   of the code  the control panel will give the following information by means of sound signals    1 short beep repeated every 3 seconds     the message has been confirmed  wait for  playback of the next voice message    4 short and 1 long beeps     the message has been confirmed  there are no more voice  messages     2 long beeps     an invalid code has been entered  the messag
54. learing osa ERGEG EEE 25  5 5 1 Alarm clearing without disarmingna aoi ai EE EE EE EEEE  25   36  Two code arming   dISAMMIINO esse recs rece sues SE OY FEE EE SE EEE EEE P EE EPEE EEEE RY EEEE EPEE EEEE RY EEC EOEEEEEP EEE 25  5 7 Triggering the alarm from Keypad s   3 225   2 2205 2ts tee ee RAs 25  30    SOP u ad al aa o a A A I A I ad 26  5 8 1 USertypeS eenean ae e 27  302     Adding NEW USEI a cs a e 28  5 8 3 EditUS ET peco a a R yer ee 28  5 8 4 Removing a USET ZZ OE Z A ER Z Z Z Z Z A Z Z 29  5 8 5 Adding proximity card   DALLAS iButton                           eeeee eee eee eee eee eee ee eccccca 29  5 09 60 Adding REVI D sesser reece ceececeescereececerstecsuee raae raet aae Paat Paat aet Peat Paat Paat iat Pian iee Faa 29  5 8 7 Removing KSYIOD ARES Eo 30   5 9    Master users  administrators  seek EEEE eska kE Eck Eee Eee kE ee EEEE EEEE Eee kE EE EEEE EEEE EEG EEG EEEE 31  5 10 Zone bypassing akad A GOA Oo a OE to 31  5 10 1 Zone inhibiting EA 31  510 2  ZONSGAINSKeG cake Piat aat Paat Paat Paan eE a 32  510 3  UnDypaSSiNg  maestro a ee a a mee eee eee 32    911  Mewing the VOM 1OG ceccceccecctvecteecececceestvectueceveceuestvecttereueceuesttectuereuecetesttectteseseseceseee 32    SATEL INTEGRA 3       5 11 1 VewNGAISENNN  a ns on A R AG AA GA R GR A a R Ga a R   a a FaZa AAAA SZA 32  5 11 2 Viewing the events required for Grade 2                                e seeeeeeaaaaareeenaneeecae 33  5 11 3 Viewing the selected events aaa a c o a A A A A DA P   rerne 3
55. ll execute one or a few of the following  functions     e starting the partition arming procedure   arming    e disarming the partition    e clearing alarm    e changing over the status of 25  BI SWITCH type outputs   e turning on the 24  MONO SWITCH type outputs    e guard round confirmation    e enabling temporary partition blocking    e unblocking cash machine access     6 2 3 Quick arming    The installer can permit arming without the user authorization     1  Select the arming mode  press one of the keys  O     full arming  1     full arming    bypasses  2     arming without interior  3     arming without interior and without entry delay      2  Press the   key  The arming procedure will begin     40 User Manual SATEL       6 2 4 Triggering the alarm from keypad    The installer can permit triggering alarms from the keypad  To trigger an alarm  do the   following    fire alarm     press the  INT S     INT SK         INT SCR  key for approx  3  seconds    medical  auxiliary  alarm     press the O key for approx  3 seconds    panic alarm     press the  INT S     INT SK          INT SCR  key for approx  3  seconds  The installer defines whether the triggered alarm will be loud  setting off the loud  alarm signaling  or silent  without loud signaling         6 2 5 Silencing the alarm sound at the keypad    If the keypad is signaling alarm  pressing any digit key will silence the signaling for approx  40  seconds     6 2 6 Code changing    The installer can permit the change 
56. menu or function is indicated by the arrow      on the left hand side     2  Press the  gt    or   key to enter the submenu  the  lt  key allows to exit the submenu  or  start the function     5 3 3 Menu shortcuts      Support for the user menu shortcuts can be disabled by the installer     You can use shortcuts for quick access to some menu elements  submenus  functions    Press the suitable digit key  or combination of keys  to enter a submenu or start a function   Shown below is the list of submenus and functions available by using shortcuts  The  shortcuts are shown in square brackets      1  Change own code   2  Users   21  New user   22  Edit user   23  Remove user    If the installer is not authorized to edit the users  the shortcuts beginning with the digit  2 will allow the installer to start the function from the MASTERS submenu      4  Zone bypasses   41  Inhibit    16 User Manual SATEL        42  Isolate   5  Events   51  Selected events   52  All events   6  Set time   7  System state   8  Outputs control   9  Service mode   0  Downloading   01  Start DWNL RS   02  Finish DWNL RS   03  Start DWNL MOD    04  Start DWNL TEL   05  Start DWNL CSD  only INTEGRA 128 WRL    06  Start DWNL GPRS  only INTEGRA 128 WRL    07  ETHM 1     DloadX   08  ETHM 1     GuardX    5 3 4 Entering data by means of the LCD keypad    Data are saved to the control panel if you press the   key  in some keypads  the D key is  also available  whose function is exactly the same   The   key ena
57. nction will be available  Press the   key     6  When a prompt appears  asking you if the changes are to be saved  press the 1 key     yee PS YS    Proximity cards   DALLAS iButtons are added to the master users  administrators  in  the same way     5 8 6 Adding keyfob   1  When adding or editing a user  run the NEw RX KEYFOB   NEW ABAX KEYFOB function   depending on which keyfob is to be added     2  Using the V and A keys  select how the keyfob is to be added  The number of keyfob  can be read during transmission by a device supporting keyfobs or entered manually    3  Press the   key    4  If the keyfob number is to be read  press twice the keyfob button according to the  instructions displayed on the keypad  When the keyfob number is displayed  press the    key    5  If the keyfob number is to be entered  enter it from the keypad  and then press the   key     30 User Manual SATEL       6  You will be brought back to the list of functions for defining the user parameters  Instead  of the NEW RX KEY FOB   New ABAX KEYFOB function  the REM  RX KEY FOB   REM ABAX  KEYFOB function will be available  Additionally  some functions appear to allow you to  configure the keyfob     Prior to assigning the zones to buttons   combinations of buttons  consult the installer     Numeration of the keyfob buttons and LEDs is described in section OPERATING THE  ALARM SYSTEM BY MEANS OF KEYFOB  p  45      7  Using the W key  find the BUTTON 1 function in the list  and then press the   key    
58. nfirmed by using the   key or the   key       card     whether it will be presented only or held     4 2 Factory default codes    By default  the following codes are preprogrammed in the control panel   service code  12345  object 1 master user  administrator  code  1111    The factory default codes make it possible to assign individual codes to consecutive persons  who are to use the alarm system  see  section USERS p  26      The factory default codes should be changed as soon as possible using the CHANGE  OWN CODE function available in the user menu     The control panel can inform the user that the code change is necessary  if the code is  known to other users     The master code should not be used on a daily basis because of the risk of its being  captured  It is recommended that the administrator enter for himself an ordinary user s  code     6 User Manual SATEL       4 3 Operation under duress    When acting under duress  the DURESS type code must be used instead of the normal user  code  see section USER TYPES p  27      5  Operating the alarm system by means of LCD keypad    SATEL offers the following keypads for INTEGRA control panels    INT TSG     touchscreen keypad    INT TSI     touchscreen keypad    INT KSG     LCD keypad with touch keys    INT KLCD     LCD keypad with mechanical keys    INT KLCDR     LCD keypad with mechanical keys and built in proximity card reader   INT KLCDK     LCD keypad with mechanical keys    INT KLCDL     LCD keypad with mechanical key
59. nication with the DLOADX program through Ethernet  using the TCP IP protocols   see  description of the ETHM 1     DLOADX function  available in the DOWNLOADING  submenu   It can be entered as a name or IP address     GuardX IP     enables programming the address of the computer  on which the GUARDX  program is installed  The address must be set if the control panel is to initiate  communication with the GUARDX program through Ethernet  using the TCP IP protocols   see  description of the ETHM 1     GUARDX function  available in the DOWNLOADING  submenu   It can be entered as a name or IP address     Erase service message     allows the user to delete the service message   Tests     the following functions are available in the submenu     Partitions     allows to check the status of partitions accessible to the user and operated  from the keypad  The partition status is presented by means of a symbol  The numbers  placed on the glass allow you to identify the partition numbers  By factory default  the  partition status is shown using the following symbols  which can be changed by the    installer     b   temporary blocked        entry delay    E   exit delay  less than 10 seconds    e   exit delay  more than 10 seconds    P   fire alarm    A   alarm    p   fire alarm memory     SATEL INTEGRA 21         alarm memory    a   armed    AE   disarmed  not ready to be armed  violated zones      disarmed  ready to be armed     Zones     allows to check the status of zones in the part
60. of own code by means of the partition keypad    1  Press the 1 key for 3 seconds    2  When the    and    gt  LEDs start blinking alternately  enter the old code and confirm it  with the   key     3  When the La and T   LEDs start blinking alternately  enter the new code and confirm it  with the   key     7  Using the entry keypad    The INT SCR multifunction keypad can work in the entry keypad mode  INT ENT   The main  task of the zone keypad is activation of the delay for the 3  INTERIOR DELAYED type zones  The  time period during which these zones will act as delayed ones is programmable for the  keypad  If more than one zone keypads are assigned to the partition  a different delay  unblocking time can be programmed for each of them  After expiry of the programmed time   the interior delayed zones will again operate as instant ones     7 1 LED indicators    Only the     LED is used  Blinking of the LED indicates that the delay activation time  countdown is running  disarming has no effect on the LED blinking      7 2 Sound signaling    The installer can disable the sound signaling or replace it by blinking of keypad  backlight   During operation  the keypad can generate the following sounds     1 short beep     pressing any digit key  confirmation that code has been entered or card has  been read     3 short beeps     confirmation of delay activation     4 short and 1 long beeps     confirmation of the guard round or execution of the control for  24  MONO SWITCH or 25  BI 
61. on to keyfob button 1   assign function to keyfob button 2   assign function to keyfob button 3   assign function to keyfob button 4   assign function to combination of keyfob buttons 1  amp  2  assign function to combination of keyfob buttons 1  amp  3  set event generating rules   add keyfob supported by ABAX system  remove keyfob supported by ABAX system  assign function to keyfob button 1   assign function to keyfob button 2   assign function to keyfob button 3   assign function to keyfob button 4   assign function to keyfob button 5   assign function to combination of keyfob buttons 1  amp  5  set event generating rules   set confirmation rules   program user name    edit existing user     list of parameters identical as in case of a new user     SATEL INTEGRA 13       Remove user    remove user    New master add new master  Code set code  Rights assign rights    Keypads etc   New prox  card  Rem  prox  card  New DALLAS  Remove DALLAS  New RX keyfob  Rem  RX keyfob  Button 1   Button 2   Button 3   Button 4   Button 1 and 2  Button 1 and 3  Events  RX    New ABAX keyfob  Rem ABAX keyfob  Button 1   Button 2   Button 3   Button 4   Button 5   Button 1 and 5  Events  ABAX   Confirm   ABAX   Name    assign modules available to the master   add proximity card   remove proximity card   add DALLAS iButton   remove DALLAS iButton   add 433 MHz keyfob   remove 433 MHz keyfob   assign function to keyfob button 1   assign function to keyfob button 2   assign function to keyfob but
62. one of the partitions accessible to the user is armed       there is no alarm   Two functions are available in the menu   Arm all arming all partitions  Arm selected arming selected partitions    5 2 2 Disarming menu    The disarming menu will be displayed if       the user is authorized to disarm the partition       the user has access to a number of partitions operated from the keypad       at least two partitions accessible to the user are armed    Two functions are available in the menu    Disarm all disarming all partitions   Disarm selected disarming selected partitions    5 3  Code  k     user menu    After you enter the code and confirm using the    key  the user menu will be displayed  The  list of available functions depends on the user authority level  as well as the system status  and configuration  In order to exit the user menu  press the   key  The keypad will quit the  menu automatically  if 2 minutes have elapsed since the last keypress     Upon entering the code and confirming with the   key  a message about the need to  change the code or a service note may be displayed     5 3 1 Functions list    The functions available after entering the service code have been highlighted with  white text against black background  Highlighted with a frame are functions available  to the administrators     View clear  al  view cleared alarms from selected partition zones  restore system after verified alarm  Disarm disarm selected partitions   Clear alarm clear alarm   Cle
63. ot violated  the device controlled by output is inactive      The way of presenting the status of roller shutter outputs differs from how the status of  other outputs is presented  see  section CONTROLLING THE ROLLER SHUTTER OUTPUTS      5 14 1 Controlling the MONO switch type of output    When the output is inactive       pressing the b key will activate the output for the time programmed by the installer         pressing the   key will allow you to program the time for which the output will be  activated upon the next pressing of the   key     When the output is active  pressing any digit key will turn the output off     5 14 2 Controlling the BiswitcH type of output    Pressing the   or    key will change over the output status  Additionally  when the output is  active  pressing any digit key will turn the output off     5 14 3 Controlling the REMOTE SWITCH type of outputs    Depending on how the output has been programmed  pressing the   or b key will activate  the output for the time programmed by the installer or change over the output status   Additionally  when the output is active  pressing any digit key will turn the output off     5 14 4 Controlling the roller shutter outputs    The SHUTTER UP and SHUTTER DOWN type of outputs are always programmed as consecutive  and in pairs  Displayed on the list of outputs is only the name of output programmed as  SHUTTER UP  The status of outputs is presented by means of symbols        outputs inactive  off         ie    I   SH
64. partition status    Events     the submenu contains functions which allow to view the events saved to the control  panel memory  see  section EVENT LOG REVIEWING p  32      The content of received SMS messages is also saved to the events log of the  INTEGRA 128 WRL control panel     Reset zones     running the function will result in a temporary deactivation of the  43  RESETABLE POWER SUPPLY type outputs  thus making it possible to reset the alarm  memory for detectors supplied from those outputs  e g  fire detectors     Clear latched outputs     allows to turn off some of the control panel outputs for which the  LATCH option is enabled  as well as the 9 DAY ALARM  12  SILENT ALARM  and 116  INTERNAL SIREN type outputs    Fin f door open     restores the normal operating mode in all modules executing the access  control functions  in case of fire  the doors controlled by these modules may be  automatically unlocked     Change options     the following functions are available in the submenu    Keypad chime     turns on off the chime signal in the keypad  signaling violations of  selected zones      20 User Manual SATEL       Outputs chime     allows to block the chime signal from selected partitions on the  11  CHIME type output     Timers     allows to program parameters of the timers  the editing of which is permitted by  the installer     Partition timers     allows to program the partition timers  see  PROGRAMMING THE  PARTITION TIMER p  34      No expanders tamper alarms
65. rigger a silent alarm  By default  it consists of a suitable number of digits 4  e g  if the  determined prefix length is 3  the default prefix is 444      Users     the following functions are available in the submenu   New user     allows to create a new user  see  section ADDING NEW USER p  28    Edit user     allows to edit the existing users  see  section EDIT USER p  28    Remove user     allows to remove the existing users  see  section REMOVE USER p  29      The administrator defines whether the installer is to have access to the USERS  submenu  SERV  CAN EDIT option in the CHANGE OPTIONS Submenu    Masters     the submenu provides the following functions available to the installer   New master     allows to create a new administrator   Edit master     allows to edit the existing administrators   Remove master     allows to remove the existing administrators   Zone bypasses     the following functions are available in the submenu   Inhibit     allows to temporarily bypass the zones  see  section ZONE BYPASSING  INHIBIT   p  31    Isolate     allows to permanently bypass the zones  see  section PERMANENT BYPASSING   ISOLATE  p  32      Set time     allows to program the control panel clock  The data are entered in the following  format     time     hour minute second   date     day month year    System state     allows to view the troubles and  if the GRADE 2 global option has been  enabled by the installer  also the alarms and bypassed zones  as well as to check the  
66. rtitions are armed  blinking     some keypad operated partitions are armed or exit delay  countdown is running                   rB  red ON or blinking     alarm or alarm memory   L2   r ellow blinking     trouble or trouble memor   A   j y    Q    green blinking     service mode is entered    4 green if zone status is being presented or the keypad is switched to graphic    programming mode  see  section SELECTION FROM THE MULTIPLE   CHOICE LIST p  16   two LEDs indicate which data set is being  displayed  see  table 2    Table 1  Description of keypad LEDs              LED     Data type i i f Information  left side upper right side lower   numbers 1 32  numbers 33 64  numbers 65 96  numbers 97 128  system addresses 0 31  00 1F HEX   system addresses 32 63  20 3F HEX     Table 2  Information presented by the B   LEDs           Zones Outputs          Expanders                Information about the armed state can be extinguished after a time period defined by  the installer     If the installer has enabled the GRADE 2 option         the    LEDs provide information about alarms only after the code has been  entered and confirmed with the   key     SATEL INTEGRA 9           blinking of the T   LED means that there is a trouble in the system  some zones  are bypassed  or that there was an alarm     5 1 3 Keys    The keys designated with digits and letters enable entering the code and data  when using  the functions available in the menu  Additionally  if you press and hold down th
67. s    INT KLCDS     LCD keypad with mechanical keys    INT KLFR     LCD keypad with mechanical keys and built in proximity card reader     The keypads are available in a variety of color options for the enclosure  display and key  backlight  The color variant is indicated by the additional designation in the keypad name   e g  INT KLCD GR     green display and key backlight  INT KLCD BL     blue display and key  backlight      5 1 Keypads description    The INT TSG  INT TSI and INT KSG keypads are described in separate manuals   which are delivered with these keypads     5 1 1 LCD display    The display facilitates communication between the user and the alarm system  clearly  indicating the system status  The functions available to the user are presented on the display   The display backlight can be used  if needed     In standby mode  the display shows       in the upper line     the date and time in the format defined by the installer         in the lower line     the keypad name or state  status  of selected partitions  to be defined  by the installer      The installer can configure the keypad so that when you press the 9 key for approx  3  seconds  the display will enter the partition state presentation mode  The status of  partitions operated by the keypad  including those from which alarm is signaled on the  keypad  is presented by means of symbols  The display will return to the standby mode after  you press the 9 key for approx  3 seconds again    If some predefined e
68. st transmission via GPRS  only INTEGRA 128 WRL   start messaging test   display information on answered tel  call   check proximity card number   start mimic board test    view master users    SATEL INTEGRA 15                   Keypad name display keypad name  File in DloadX display inf  on DLOADX program file with control panel data  Panel version display information on control panel firmware version  STM prg version display inf  on ABAX syst  firmware  only INTEGRA 128 WRL   GSM IMEIU V sig  display information on GSM telephone  only INTEGRA 128 WRL   IP MAC ETHM 1 disp  inf  on ETHM 1   ETHM 1 Plus module IP and MAC address  Modules version display information on module firmware version  Time synchron  start time synchronization   Service access set installer access time   Open door open selected door controlled by system   Outs control control outputs            start service mode  take over service mode  Downloading  start local programming  finish local programming          Start DWNL MOD  start communication via external modem   Start DWNL TEL start communication via 300 bps modem   Start DWNL CSD start CSD communication  only INTEGRA 128 WRL   Start DWNL GPRS start GPRS communication  only INTEGRA 128 WRL   ETHM 1     DloadX start communication via Ethernet with DLOADX program  ETHM 1     GuardX start communication via Ethernet with GUARDX program    5 3 2 Starting functions  1  Using the V and A keys  find the required submenu or function  The currently selected  sub
69. t be called  The  arming will only be possible after the installer intervention  see  description of the  SYSTEM RESET function  p  18      Bypassing violated zones when arming    If the arming procedure could not be started  and a message on the display informs you that  there are violated zones  you can review the list of such zones upon pressing the 2 key  To  scroll through the list  use the W and A keys  Pressing the 4 key will allow you to bypass the  given zone  A message on the display will prompt you to press the 1 key to confirm that the  zone is to be bypassed     Forced arming   If the arming procedure could not be started  the displayed message can allow of the forced  arming  1 Arm   On pressing the 1 key  the system will be armed despite a violated zone or a  trouble     SATEL INTEGRA 25       5 4 6 Failure of arming procedure  If the installer has enabled the GRADE 2 option  the arming procedure may end in failure  The  system will not be armed  if at the end of the exit delay countdown         there is a violated zone in partition which was not violated when the arming procedure  was started         there is a trouble which did not exist when the arming procedure was started     5 4 7 Shortening the exit delay time    If such an option is permitted by the installer  the partition exit delay time may be shortened  upon pressing in turn the 9 and H keys     5 5 Disarming and alarm clearing    Enter the code and confirm with the   key  see  section  Cope       A
70. t is  necessary to specify the object in which the new user is to be created  the service  code enables access to all objects      3  Using the appropriate functions  define the user s parameters     At least one identifier  i e  code  proximity card  DALLAS iButton or keyfob  must be  assigned to the user     The new user may not be granted a higher authority level than the person who is  adding that user to the system    4  Press the   key    5  When a prompt appears  asking you if the changes are to be saved  press the 1 key     6  A message will inform you that a new user has been created  Press the   key to return to  the USER submenu     5 8 3 Edit user    The user can edit the users in relation to which he she is the superior  For example  if  the user A has created the user B  and the user B has created the user C  then the  user A can edit the users B and C     The user being edited may not be granted a higher authority level than the person who  is editing such a user     1  Enter the code and confirm with the   key   2  Press the 2 key twice  The list of users will be displayed     SATEL INTEGRA 29       Using the V and A keys  find in the list the user who is to be edited    Press the   key  The list of functions for defining the user s parameters will be displayed   Using appropriate functions  modify the user s parameters    Press the  K key    When a prompt appears  asking you if the changes are to be saved  press the 1 key     A message will inform you that th
71. teps 1 2 in section ANSWERING PHONE  CALLS     2  Within up to 15 seconds  press in turn the 2 and   keys on the telephone keypad  4 short  beeps and 1 long beep will confirm that you have got access to the telephone control  function    3  Within up to 15 seconds  enter the 2 digit number of the remote switch  e g  01  07 or 15    The control panel will inform you about the switch status change by means of sounds    3 short beeps     the switch has been turned off   4 short and 1 long beeps     the switch has been turned on     4  Upon pressing in turn the 0 and   keys on the telephone keypad  the control panel will  hang up  You can also press the 1 and   keys to return to the phone call answering  function     The operating mode of the REMOTE SWITCH type output depends on how the output has  been configured by the installer        10 3 Audio alarm verification    Remote audio alarm verification is possible when the INT AV module is connected to  the control panel     1  Get access to the phone call answering function  steps 1 2 in section ANSWERING PHONE  CALLS      2  Within up to 15 seconds  press in turn the 3 and   keys on the telephone keypad  4 short  beeps and 1 long beep will confirm that you have got access to the function of audible  alarm verification  The DTMF commands you can use after starting the listen in   talk  session are described in the INT AV module manual     SATEL INTEGRA 45       11  SMS control easter LIS    The INTEGRA 128 WRL control panel can b
72. the time is shorter than 10 seconds  only  the final sequence of short beeps will be generated      A sequence of 7 beeps of diminishing duration  repeated every few seconds      countdown of auto arming delay     2 short beeps every seconds     countdown of entry delay   2 short beeps every 3 seconds     signaling a new trouble   Continuous beep     alarm    Long beep every second     fire alarm     5 2  Code       arming   disarming menu    Information given in the section below do not apply to users having the SIMPLE USER  right  see p  27    After you enter the code and confirm it with the   key        amessage on the need to change the code or a service note may be displayed        alarm will be cleared     if the user is authorized to clear the alarm and there is an alarm  in the system        one partition will be disarmed     if the user is authorized to disarm the partition  has  access to only one partition operated from the keypad and that partition is armed  or has  access to many partitions  but only one partition is armed        one partition will be armed     if the user is authorized to arm the partition  has access to  only one partition operated from the keypad and that partition is disarmed         the arming disarming menu will be displayed     SATEL INTEGRA 11       5 2 1 Arming menu    The arming menu will be displayed if       the user is authorized to arm the partition       the user has access to a number of partitions operated from the keypad       n
73. ton 3   assign function to keyfob button 4   assign function to combination of keyfob buttons 1  amp  2  assign function to combination of keyfob buttons 1  amp  3  set event generating rules   add keyfob supported by ABAX system   remove keyfob supported by ABAX system   assign function to keyfob button 1   assign function to keyfob button 2   assign function to keyfob button 3   assign function to keyfob button 4   assign function to keyfob button 5   assign function to combination of keyfob buttons 1  amp  5  set event generating rules   set confirmation rules    set master name    Edit master   select master    list of parameters identical as in case of a new master   Remove master  Zone bypasses    edit existing master    remove master    Inhibit temporary zone bypass  Isolate permanent zone bypass  Set time set control panel clock  System state check troubles   check system state  Events  Selected  Select events select type of events to be viewed  Select part  select partitions from which events are to be viewed    View view selected events    14    User Manual SATEL       View Grade2  All  Grade2  Reset zones  Clr latch outs  Fin f door open  Change options  Keypad chime  Outputs chime  Timers  Part  timers  Perm serv accs   Serv  can edit  Serv  ArmDis     Perm DloadX acc  DloadX IP  GuardX IP  Erase s message  Tests  Partitions  Zones  Radio devices  Temperatures  Zones test  New  Burglary zones  Fire tech zones  View results  Finish test  Clear results  Manual tr  t
74. uence of short beeps will be generated      SATEL INTEGRA 39       A sequence of 7 beeps of diminishing duration  repeated every few seconds      countdown of auto arming delay     2 short beeps every second     countdown of entry delay   Continuous beep     alarm    Long beeps every 2 seconds     alarm memory    Long beep every second     fire alarm    Short beeps every 2 seconds     fire alarm memory   Very short beeps     door open too long     6 2 Functions available from the partition keypad    6 2 1  Code  k    Depending on the user type and authority level  keypad settings and the alarm system status    entering the code and confirming with the    key will execute one or a few of the following   functions    e unlocking the door  activating the relay     e disarming the partition    e clearing alarm    e changing over the status of 25  BI SWITCH type outputs    e turning on the 24  MONO SWITCH type outputs    e guard round confirmation    e enabling temporary partition blocking    Most of the abovementioned functions are available after enabling the LOCK  LOCK  FEATURE  option for the partition keypad  Whether the functions are available may also    depend on the other keypad options  e g  if the lock operates in the ON IF PARTITION  ARMED  ON IF PART ARMED  mode  most of the functions will be unavailable      6 2 2  Code      Depending on the user type and authority level  keypad settings and the alarm system status   entering the code and confirming with the   key wi
75. vents occur  additional messages may appear on the display  e g   arming  disarming  auto arm delay countdown  entry exit delay countdown  alarm  etc     Entering the user code  i e  the user authorization  will open a menu containing the functions  that are available to the user  The functions are presented in two lines  The currently selected  function is indicated by the arrow on the left hand side  How the function related information  is presented depends on the specific character of the given function     The way of display backlighting is programmed by the installer     SATEL INTEGRA 7       INT KLCD   INT KLCDR INT KLCDK                                                 7 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32                                                    integra                      U  O BA   4  EJ Ce  LD    e  7     GH  M    3                             7  6E                CHJ Lo                                                                                    INT KLFR    7 PQRS 8 TUV 9 WXYZ  Gs Em Es  lt       go og  cj                Fig  1  Keypads with flap        8 User Manual SATEL       INT KLCDS INT KLCDL                                                                                                                                                                                                                      Fig  2  Keypads without flap        5 1 2 LED indicators    LED Color   Function description     o green ON     all keypad operated pa
76. with the   key  but only when none of the partitions  accessible to you is armed and the keypad is signaling no alarm     5 4 3 Arming in the selected mode    1  Enter the code and confirm with the     key   2  Using the V key  scroll through the menu until the ARMING MODE function is found     3  Press the   key  A list of arming modes will be displayed  see  description of the ARMING  MODE function  p  18      4  Using the A and V keys  find the arming mode which is to be activated  and then press  the   key     5  When the ARM function is displayed  press the   key  Proceed in the same way  as for  the full arming of selected partitions  steps 4 7      5 4 4 Quick arming  The installer can permit the arming without user authorization  The partitions indicated by the  installer will be armed     1  Select the arming mode  press one of the keys  0     full arming  1     full arming    bypasses  2     arming without interior  3     arming without interior and without entry delay      2  Press the   key  The arming procedure will begin     5 4 5 Denial of arming  The installer can program the control panel so that the arming procedure could not be  started  if        azone is violated in the partition        there is a trouble in the system  including tamper         there was a verified alarm     The keypad will inform you about the refusal to arm by means of a message specifying the  cause for refusal     1 If after a verified alarm the arming is impossible  the installer mus
77. y  appropriate services will be notified   etc    which may deter the potential burglars     The SATEL s goal is to continually upgrade the quality of its products  which may result in  alterations of their technical specifications and firmware  The current information on  the introduced modifications is available on our website    Please visit us at   http   www satel eu    The declaration of conformity may be consulted at www satel eu ce    Factory default codes   Service code  12345  Object 1 master user  administrator  code  1111    The following symbols may be used in this manual       note   A   caution     Changes made to the firmware version 1 13  User menu Support for the user menu shortcuts can be disabled by the installer   For some functions  when editing the multiple selection lists in text    mode  you can press the key 0 and enter the number of element  e g   zone  partition  to be edited           2 User Manual SATEL  CONTENTS   1  Generalerna A 020 204000400 DTD RO OS 4  2  Technical reliability of the alarm system                   4    44 4 euuueeeeee aaa aaa aaa wawa a 4  3  Alarm system operating COSIS ea ea oO AERO AEK KORE GEEK REKE 4  4    Authorization Of WIS OS    Ra OG oi AG R a R GREG 5  4 1 Authorization with two identifiers      ccnti ee 5  4 2  Factory default CONS aaa ia a nisaire ERSE erken ERSE wa   5  4 3 Operation under duress a A O tae 6  5  Operating the alarm system by means of LCD keypad                            eaaaaaaaaaaaaaaaaaaaaa
    