Home
The MPC3 System Service Manual
Contents
1. ae RET estat cet 48 48 ALARM NOTIFICATION LEVELS cccccccccccccccceccecceccecccecuecteccecuueaueauestesuucauesutstesuueauesnesnes 49 The MPC 3 System Application Service Manual BASIC INFORMATION ON THE MPC SYSTEM System Description The System is designed for cooperation with specialized controllers manufactured by MIKSTER which record and control manufacturing processes among others in smoking brewing chambers heat boilers drying chambers vacuum mass devices The MPC System delivers documentation in compliance with the HACCP requirements Current version supports the following controllers INDU WRC 2000 DAT 120 100 026 2100 050 106 051 Functional Properties equipment status monitoring allowing to check the following which processes are activated in controllers values of preset and read out parameters which devices are switched on by the controller collected data readout from controllers review of collected data coming from controllers either in form of tables or graphs collected data printouts tables and graphs System Requirements Minimum hardware requirements computer with Pentium processor 64MB RAM recommended 128 MB RAM 1 free RS232 port required disk space for installation a
2. polish sausage 0000002 Product german wurst Identifiers allow for more accurate manufacturing process description we may thus determine not only product name but its properties as well mec ee The 3 System Application Service Manual Overlap Product Identifier Controller settings E X WRC 2000 __ Type WRC 2000 Cancel Iw Active Process names Operators Identification 10 Article 4 The way af division successive groups Number of characters Group 1 Group 2 Group 3 Group 4 Group 5 Group b Group Group Overlap Product Identifier allows to define identifier division in this case group has one character group two has two characters whereas the last third defined group has five characters Identifier will be as follows 2 03 01030 s The MPC 3 System Application Service Manual Authorized Program Users List Access to users list is possible after logging in the program with administrator rights Select item File in upper menu then select Users List Window Users List will appear It contains users who have access to the program Here we can add new user or change settings for already existing user Press with mouse L to add a new user When all fields are filled in press OK or ENTER key on keyboard to save data HIA 151 OK User mpc M Cancel MPC
3. Password Reenter new password Co Access level OPERATOR Definitions f fields in USERS LIST window User Enter user s code which will be used by the user while activating the program Surname name User s surname and name Access rights Three authorization levels are available to choose only review operator administrator First two allow for access to basic program functions The administrator level allows to modify controllers and change program parameters Attention The program has the following authorization levels for users OPERATOR basic functions available ADMINISTRATOR service functions for administrator Window User Login appears immediately after program activation Enter User s code assigned by the administrator in the window user line and then your password mec ee The 3 System Application Service Manual x ser MFC Password Default users codes after program installation User Password Authorization level mpc no password operator Adm no password administrator Attention Previous MPC versions did not have User mpc Oper was available instead of it 34 The 3 System Application Service Manual SYSTEM ADJUSTMENT TO USERS NEEDS Header and footer Description Each printed process consists of header and then of recorded samples and footer User may adjust printout header and footer appearance First
4. i Indu WRC 2000 __ WRC 2000 Cancel Take from the group MEN 1iJohn Golle 2 Mike Sanders 3 Martin Footloker The 3 System Application Service Manual Program Groups Program groups allow to define names for programs manufacturing processes set in the controller 191 m fn MCC 100 EIE 1 polish sausage 2 salami 3 german wurst E Select Close gt The 3 System Application Service Manual Identifier Types An identifier determines feature described by value entered by an operator in a controller dentifier types aag d Product m i j j j j j i i j i i i j x Identifier Groups This function allows to attribute name and type for a specific identifier Identifier groups a tlforMcc 100 2 MCC 100 T Identifier identifier Twe 0000001 Product 0000002 Product polish sausage german wurst 18 The 3 System Application Service Manual Type Product TN 19 The 3 System Application Service Manual Identification Setting Example The controller possesses an 8 character identifier The first identifier digit indicates cart quantity next 4 product code and another 3 char
5. 0400 g 0 2005 10 18 1338 2 00 25 04 20 g 0 2005 10 18 1229 2 0026 0400 g 0 2005 10 18 13 40 2 00 27 04 20 95 0 2005 10 18 1341 2 0028 0400 g5 0 2005 10 18 13 42 2 0029 0400 a 0 2005 10 18 13 43 2 0030 0400 a 0 Page 1 of 1 36 The MPC 3 System Application Service Manual ADMINISTERING THE MPC SYSTEM Administrative operations shall be carried out with care Improper modifications introduced by user with administrator rights may result in data loss and faulty system operation Usual everyday work with the system should be carried out after logging in with operator rights Process Removal from the Program Administrator is able to remove a process from the program Open window Processes List and then press on keyboard function key F10 push button Remove Process will appear After pressing it box with request to confirm indicated process removal will appear The process will be removed after confirmation Push button Remove process will be hidden after pressing key F10 again OPERATOR S WORK IN THE MPC PROGRAM Program Activation In order to activate the program press push button Start on taskbar then Programs group Mikster abbreviation mpc Window User s Login will appear enter your own user s code and password and press push button OK Attention if there are no modifications introduced by administrator default operator s code is mpc in older program versions Ope
6. 18 13 26 2 00 13 2005 10 18 1327 2 00 14 2005 10 18 13 28 2 00 15 2005 10 18 13 28 2 00 16 2005 10 18 13 20 2 00 17 2005 10 18 13 21 2 00 18 11 19 1329 nna Page 1 of 1 Set C Time Set T Cha Set Hum 04 00 J5 0 04 00 J5 0 04 00 g5 0 04 00 g5 0 04 00 g5 0 04 00 g5 0 04 00 g5 0 04 00 g5 0 04 00 95 0 04 00 95 0 04 00 95 0 04 00 95 0 04 00 g5 0 04 00 J5 0 04 00 g 0 04 00 g5 0 04 00 g5 0 04 00 g5 0 04 00 95 0 na nn n x 46 The 3 System Application Service Manual COMMENT As soon as this is pressed a window will open allowing to enter your comments regarding the process DC M7 1 Start of process 2005 10 18 13 13 Controller Indu WRC 2000 Program 1 Product Cancel 47 The MPC 3 System Application Service Manual PROGRAM SETTINGS Activate Audio Alarm This option activates deactivates sound alarm Settings Sound onoff Print settings Email properties Alarms E mail Settings Set notification by e mail Enter SMTP server name Port usually 25 Sender e mail address User s name Password Check option Send notification message on system status Send alarms via E Mail 1 X Send alarms via E Mail SMTP server __ Cancel Cancel SMTP server mail server cam Part E C E mail address addressiciserver cam User name user Password Sen
7. Password Reenter new password g Access level CFERATOR List of Events Select this icon in order to preview the list of events in the program Icon definitions all events program settings rg s equipment settings V e mail notification messages The 3 System Application Service Manual 2005 10 18 1 Ga Verify data integrity Administrator 2005 10 18 13 09 Change data and Time Indu 2000 Administrator 2005 10 16 13 09 Configuration gt Controllers list Administrator 2005 10 18 13 03 Configuration Controllers list Administrator 2005 10 16 12 54 Configuration Controllers list Administrator 2005 10 18 12 46 Configuration Controllers list Administrator 2005 10 16 12 48 Login Administrator 2005 10 17 09 45 Header and footer Administrator 2005 10 17 09 43 Login Administrator 2005 10 17 09 45 Error logging Administrator 2005 10 17 09 42 gt Users Administrator 2005 10 17 09 42 Login Administrator 2005 10 10 12 10 Login Administrator 2005 10 10 12 08 Configuration Controllers list Administrator 2005 10 10 12 06 Configuration Controllers list Administrator 2005 10 10 09 58 Login Administrator 2005 10 10 09 32 Configuration Controllers list Administrator 2005 10 10 09 18 Configuration Controllers list Administrator 4 7 11 The MPC 3 System Application Service Manual Security Back
8. header line may contain information including company name address department Header and footer x Header __ Cancel Print tooter End Char footer End Show channel Humidity Bartemperature 286 The 3 System Application Service Manual MPC inl x gt n ga c eatF actory 00 000 City Street Process 1 Controller Indu vy RC 2000 Start 200 1018 13 13 End 2005 1018 13 43 Program 1 D ate amp time Cycle cycle time Temperature Humidity Set Time Set T C Set C c 2005 10 18 13 13 2 0000 0400 95 0 2005 10 18 13 14 2 0001 0400 95 0 2005 10 18 13 15 2 0012 0470 a5 0 2005 10 18 13 16 2 0003 0400 a 0 2005 10 18 13 17 2 0004 0400 a 0 2005 10 18 13 18 2 0005 04 20 g5 0 2005 10 18 13 19 2 0006 04 20 g5 0 2005 10 18 1320 2 0007 04 20 g5 0 2005 10 18 1321 2 0018 04 20 g 0 2005 10 18 1322 2 0009 04 20 g 0 2005 10 18 1323 2 00 10 04 20 g 0 2005 10 18 1324 2 00 11 04 20 g 0 2005 10 18 1325 2 00 12 04 20 g 0 2005 10 18 1326 2 00 13 0400 g5 0 2005 10 18 1327 2 00 14 0400 95 0 2005 10 18 1328 2 00 15 04400 g5 0 2005 10 18 1329 2 0016 0400 a 0 2005 10 18 1320 2 DO 17 0400 a 0 2005 10 18 1321 2 00 18 04 20 g5 0 2005 10 18 1332 2 00 19 04 20 g5 0 2005 10 18 1333 2 0020 04 20 g5 0 2005 10 18 1324 2 0021 04 20 g 0 2005 10 18 1335 2 00 22 04 20 g 0 2005 10 18 1226 2 00 25 04 20 g 0 2005 10 18 1337 2 0024
9. lastcopy Base recovery from the copy MOTE Prior to the selection of this un option all connections with the base must be closed Advanced repair in the case when the simple repair will not be Successful Automatic Archive Settings The automatic archiving function is available in Service Automatic Archive Settings menu It is possible to enter setting allowing the program to make automatic data archiving in order to do that check option Create automatic archive enter the path to the directory in which copies are to be saved set the frequency in months for making the archive e g every month enter the day of month in which the archiving will be carried out e g on 3 day of the month We recommend to check function Delete data from original database after creating an archive this has advantageous effect on database functioning Lx archive select directory C Program Files MiksterWMPCs 243 The MPC 3 System Application Service Manual Select Directory Directory M ame C Program Files shlikstert PL 3 EM Sdata Directories Files Program Files Mikster EMG Drives Cancel In case if the option Delete data from original database after creating an archive is checked the program will automatically create a directory containing data according to the pattern currentyear currentmonth e g if current year is 200
10. operation is completed window Collected data readout will close 40 The 3 System Application Service Manual Manufacturing Processes Preview You can activate the processes preview function from program main window by pressing push button PROCESSES Window Processes List will appear containing the list of processes which have been registered in the program es 4 identification Type The field Controller contains list of controllers available to choose Preset default value makes processes from all controllers visible If you choose for example CHAMBER 01 only processes from CHAMBER 01 will be displayed 41 The 3 System Application Service Manual Push button definitions Opens window Process Graph in which selected process graph will be drawn User may alter graph appearance and may instruct the program to show on the graph measurement points indicator our innovation is graph shown in three dimensional form E C Show sample marks 3D View Phase visible Pointer Line width Cycle F indu WRC 2009 2005 10 18 13 12 2005 18 16 18 41 42 The 3 System Application Service Manual c m BEER E E a Eo Cycle cycle time It is possible to switch on and off particular channel on graph e g in this case us
11. 5 and current month is May then the program will create directory 2005 5 in specified directory C Program Files Mikster MPC3 TEMPARCH and transfer there all data older than 3 months in order to relieve the database Access to these data is always possible in order to check older data enter the directory containing archived data and run the mpc exe application stored in the archive directory The 3 System Application Service Manual Dictionaries Vocabulary data which include the operator groups and program groups Operator Groups Controller operators may be assigned to specific devices Operator groups 1 lindu WRC 2000 operators Operators 1 Jahn Galle 2 Mike Sanders 3 Martin Footloker As soon as operators are entered it is possible to download entries in the menu Controllers settings Controllers list In order to assign operators to devices select icon from the Operators group MPC System File Controllers Settings Controllers list DAT 120 Pr 15 The 3 System Application Service Manual Controllers list 1 DAT 120 0 1 Indu 2000 16 Click twice the device INDU WRC 2000 in order to shift to edition of entries Going to the overlap Operators it is possible to download previously entered operators Click icon Take fram the group to download operators from the group Controller settings X Marne Ma
12. MAX PRESET TEMP 200 BAR PRESET TEMP This overlap allows to check controller setup enter modifications compare the setup and send new settings to the controller 28 The 3 System Application Service Manual Overlap Alarms Controller settings 2000 Type WRC 2000 Cancel v Active Controller datetime Setup Alarms Alarm names Proces 4 BE Operator 2 head operator 3 factory owner This overlap allows to set alarm occurring with preset delay In this case operator will be informed about alarm occurrence after 3 minutes operator s superior will be informed after 5 minutes and the last person to be informed is the company manager Alarm delay may be declared freely 29 The 3 System Application Service Manual Overlap Names of programs Controller settings WRC 2000 00 WRC 2000 Cancel v Active setup Alarms Alarm names Process names Operators 4 In this overlap it is possible to attribute own names to program numbers Moreover user can take them from program group defined earlier 30 The 3 System Application Service Manual Overlap Identifiers CTE x WRC 2000 00 __ Cancel WRC 2000 Active Defined identifiers Kinds according to identifier s number
13. The System Service Manual Sp 2 41 250 Czeladz ul Wojkowicka 21 POLAND Phone 48 32 763 77 77 Fax 48 32 763 75 94 www mikster com info mikster com v 1 01 18 10 2005 TABLE OF CONTENTS BASIC INFORMATION ON THE MPC SYSTEM eere Ie 3 SYSTEM DESCRIPTION 25 xod dv Xud22 dud ouai uu dd duds dian 3 FUNCTIONAL PROPERTIES ce eee dressed tesa du tient Mares deren eerie DEAE LAM EAE LAM Aenean UE 3 SYSTEM REQUIREMENTS 3 PROGRAMING ION o EE 4 DATABASE SETUP 4 VAIN S CREE PD TEUER 5 RECORDING COLLECTED DATA VERIFICATION ccceccceceeecceeeceeeceeceeseeeeeeseueeaeeeeeseeeseess 7 9 10 SECURITY BACKUP SETTINGS ranne 12 DATABASE OPTIMIZATION 12 AUTOMATIC ARCHIVE SETTINGS cccececcccececcccaceccccaceccacaceneacaceneacsceneacsneeateneatansneananenss 13 PIG TION ARIE 15 OPERATOR GROUPS cccececececececcccccececececcauaecacececeneauaeacsueseneauauaeseeseneaeauaescseeneeauaneeas 15 PROGRAM GROUPS 17 Ug SSL R Ue gt 18 ID ENGI IER d
14. acters no meaning Group shall be defined in the first place In order to do that log in as administrator and go to Menu File Service Dictionaries Process Identification Identifier Groups iol xi Fie Controllers Settings Logout 49 92 Vm Dictionaries Identification Identifier types LEE verify data integrity Operator groups Identifier groups Users Events report Security backup Database optimization Automatic archive settings Programs groups Program Add a new group by pressing icon Identifier groups 2 MOl 100 ES Name 0000004 Product polish Sausage 0000002 Product german wurst Then enter the name e g MCC 100 identification and attribute ID1 name e g cart quantity 90 The 3 System Application Service Manual Name 100 Then click icon cy and add 4 character identifier for a product Identifier 10000001 Product ea Then enter controllers settings by selecting this function from menu Controllers settings Controllers list 21 The 3 System Application Service Manual Controllers list e Indu WRC 2000 WRC 2000 1 Click twice selected device e g mcc 100 and then go to overlap Identifiers and download settings from group Take from the group S
15. amples Recordings En X Process 1 x Controller Indu WRC 2000 Close tart 2005 10 18 13 13 End 2005 10 18 13 43 Product oe YCIE CYCIE ime gimp tore umi itv ime a nre 20 15 1 18 13 13 2 00 00 04 00 Start of process 2005 40 18 13 14 2 00 01 04 00 95 0 0 2005 10 18 13 15 2 00 02 04 00 55 0 0 2005 10 18 13 16 2 00 03 04 00 99 0 0 2005 10 18 13 17 2 00 04 04 00 g5 0 0 2005 10 18 13 18 2 00 05 04 00 ig 0 0 2005 10 18 13 18 2 DD DB 04 00 J35 0 0 2005 10 18 13 20 2 00 07 04 00 95 0 0 2005 10 18 13 21 2 00 08 04 00 95 0 0 2005 10 18 13 22 2 00 09 04 00 95 0 0 2005 10 18 13 23 2 00 10 04 00 Sb 0 0 2005 10 18 13 24 2 00 11 04 00 95 0 0 4 E PRINT The MPC 3 System Application Service Manual Allows to print out selected fragment or the entire process as a table MPC amp amp co Meat Factory 00 000 City Street Process 1 Controller Indu wv REC 2000 Start 2005 10 18 13 13 End 2005 40 18 13 43 Program 1 Date amp time Cycle cycle time Temperature Humidity c 2005 10 18 13 13 2 00100 2005 10 18 1314 2 0021 2005 10 18 13 18 2 0002 2005 10 18 1316 2 0003 2005 10 18 13 17 2 0004 2005 10 18 13 18 2 0005 2005 10 18 13 18 2 001056 2005 10 18 1320 2 0027 2005 10 18 13 21 2 0008 2005 10 18 13 22 2 0009 2005 10 18 13 23 2 00 10 2005 10 18 13 24 2 00 11 2005 10 18 13 25 2 00 12 2005 10
16. d system status From 23 every 24 t4 hour 48 The 3 System Application Service Manual Alarm Notification Levels This option allows to notify about alarms according to time delay List of alarm levels _ BG x Close E Mail address BEE Operator 3 operaton amp iserver com 4 head operator 5 headoperatarnciserver com 3 factory owner 15 awnertesermer cam 49
17. e consistent with the value set in a certain controller It is recommended that all devices work at the same rate Controller code it is not being entered by user directly from keyboard as soon as you press push button AUTHORIZE it will be received from controller it shall be saved after entering correct authorization code Authorization after having received controller code see before controller manufacturer provides so called authorization code Overlap Date and Time Controller settings Marre OK Indu WRC 2000 00 WRC 2000 Active Transmission Controller date time Setup Alarms Alarm 4 PC date amp time 2005 10 18 13 09 42 Controller date amp time 2005 10 18 13 09 40 send date and time to the controller when it differs from computer date and time 27 The 3 System Application Service Manual Overlap Setup TTT x findu WRC 2000 __ Cancel WRC 2000 Active Transmission Controller date amp time Setup Alarms Alarm 4 V Haad HL Compare Send Address RS 48 Haud rate 0 Central processor address 1 Central processor trans 1 Com processor address 2 1 0 Com processor V trans Temperature unit Smoke temperature 360 Plate temperature 250 Delta status 0 Sample rate mini 1 TIME FOR RESTART 40 CHAMBER
18. elect from Group x Indu WRC 2000 __ Type WRC 2000 Cancel Active Alarm names Process names perators Identification 4 Defined identifiers Kinds according to identifier s number ASA polish sausage 0000002 Product german wurst 22 The MPC 3 System Application Service Manual When going to overlap Product Identifier specify identifier division Mark selection field Product identifier division For group 1 one character For group 2 four characters For group 3 three characters etc Controller settings X Marne Ma 2000 Inn __ Type WRC 2000 Cancel Active Process names Operators Identification 10 Article 4 i Division af the product identifier The way of division successive groups Number of characters Group 1 Group 2 Group 3 Group 4 Group 5 Group b Group Group The result of this operation is recognition of an identifier entered a controller 2 0001 000 as 2 carts with Krakowska sausage lt 29 a The 3 System Application Service Manual Indu WRC 2000 Frogram 1 Product Set Readed Temp Chamber Temp Core Humidity cycle time WRC 2000 step 2005 10 18 13 13 Identification Type ame O O bo 308 6969 89 24 The MPC 3 System Application Service Manual First Activation of
19. enote Mu hua ata Sia 18 IDENTIFICATION SETTING cccececcececcccacececcacececccceceaeaceceaeaceneacsueceacsteceateneuaceneauseeneatanenss 20 ADDING AND MODIFYING CONTROLLERS SUPPORTED BY THE PROGRAM 25 CONTROLLER SETTINGS cccecececececccccccececececeacacececeueneaeacseucenecucuausesceneaevanscseeneeaeanaees 26 AUTHORIZED PROGRAM USERS LIST ececcccececcccececcccececcacececeacececeaceneaeaceeaeateneananenss 33 SYSTEM ADJUSTMENT TO USERS NEEDS eer en nnn nene 35 Header AN TOOLel ec c ted it d tato i iouis Ul A ate DATI DIL 35 ADMINISTERING THE MPC SYSTEM nnn 37 PROCESS REMOVAL FROM THE PROGRAM ceccecccceccaceccaccccacccccccaceceatececuecesueaceneaueneanes 3 OPERATOR S WORK IN THE MPC 37 PROGRAM ACTIVATION aa 37 DEVICE CHAMBER OPERATION 38 RECEIVING COLLECTED DATA FROM CONTROLLERG cccccececececececcacacecececeneneauarseenenenenss 39 MANUFACTURING PROCESSES PREVIEW ccccceccececcececcccecceccacececceaucuecceneaceceaueaeeneateneass 41 PROGRAM SETTINGQ3SS eere 48 ACTIVATE ADI AAR
20. er has switched off displaying of the following items on the graph Core Temperature Smoke Temperature Plate Temperature If necessary modify printout settings Settings Sound onoff Print settings Email properties Alarms axis ranges for temperature and humidity and time 43 The 3 System Application Service Manual Lx Chart settings Chart axis settings Colours Temperature axis lett Min values valuez 150 arid visible umidty axis right values 101 grid visible ate time arid visible Cancel Set colors for phase lines cycle lines phase names and graph background Chart settings Chart axis settings Colours Phase line color Phase FILTER Using filter it is possible to narrow the list of displayed processes In order to do that press push button FILTER Window Filter processes list will appear which allows us to specify 44 The 3 System Application Service Manual time range the program and product id As soon as push button Filter is pressed processes meeting entered criteria will be displayed Select range From 2005 10 16 T 00 00 00 Cancel To EE 2005 10 19 m 00 00 00 CONTROLLER All gt Advanced SHOW RECORDED SAMPLES soc soon as this function is pressed a window will open allowing to view recorded s
21. he program Logout Close Ha ey Frogram 03 41 MPL System File Controllers Settings 10 x A m Lm nns STEF Identification Dictionaries Verify data integrity Operator groups Identifier groups Users Programs groups Events report Security backup Database optimization Automatic archive settings Menu group Service consists of Dictionaries Verify data integrity Users list Events report Security backup Database optimization Automatic archive settings The MPC 3 System Application Service Manual Subgroup Dictionaries consists of e Identification of processes e Operator groups e Programs groups Identification of processes consists of e Identifier types e Identifier groups Verify data integrity Recordings are downloaded from controllers as temporary files LOG type These files provide basis to restore processes taking place in the program this is possible through the Collected data verification function available for program administrator Select item File Service in upper menu and then Collected data verification Window The MPC collected data verification will appear When you set time range and select the controller press push button Execute box with request to confirm execution will appear as soon as you select Yes the collected data verification process will begin Comments If a whole process is
22. missing in the program it will be added If process end is missing it will be found and completed Missing process samples shall not be added if they are newer than those already entered ones that is if there is a process with missing initial measurements then it is necessary to remove the whole process and then use the collected data verification Select verification range from to check the controller which you wish to put through the verification process and then press push button Execute The 3 System Application Service Manual Select range d From 2005 10 08 00 00 00 4 Ta 2005 10 11 00 00 00 Controller E All gt Start Information ed Verification of recording ended Verify data integrity LE Summary Close start verity 2005 10 16 13 23 All gt End 2005 10 18 13 23 The 3 System Application Service Manual Users List This function allows to add and edit users in the MPC system Click icon E to add new user clos Mame Access level A dim Adri n strato 0 gt m inistrator mpc MPL OPERATOR Enter name for that user and fill in other fields confirm correct entry with the Key The 3 System Application Service Manual ETIN tox Wf OK User mpc X Cancel Smith
23. ntroller Window CONTROLLER SETTINGS will appear fill in all fields and press push button OK 25 The 3 System Application Service Manual Controller Settings After opening window Controller settings from menu Controllers list we go to controller settings below you will find definitions of fields in CONTROLLER SETTINGS window Active device Controller activity selection field Device name usually here we enter the name of a device supported by the controller e g CHAMBER 01 Attention If you enter CHAMBER 1 then CHAMBER 1 and CHAMBER 10 will be displayed next to each other both begin from the same digit only if entered devices have numbers with preceding zeros e g 01 they will be displayed in right order Device number determined device number Overlap Transmission Controller settings OK findu WRC 2000 00 WRC 2000 Cancel Active Transmission Controller date amp time setup Alarms Alarm COM COM 1 Address RE 485 Baud rate 9600 Test 06 The MPC 3 System Application Service Manual Communication port select the port to which converter RS485 has been connected RS 485 address each device on the RS485 line possesses its unique address enter appropriate address for a particular controller Transmission rate typical 9600 b s value selected value has to b
24. pproximately 30MB Recommended minimum of free disk space for operation The TCPIP data transfer protocol 15 also required In case if the computer is connected to the network network interface card this protocol has already been installed otherwise it needs to be Installed For WindowsNT 2000 XP systems it is sufficient to install the Microsoft diagnostic loopback card while for Windows 9x systems it is required to define the connection in Dial Up networking and assign to the computer any IP number In order to ensure correct screen font display in the MPC application the screen settings should be as follows Display your screen resolution makes screen items too small to view comfortably you can increase the DPI to compensate To change font sizes only click Cancel and go to the Appearance tab setting Normal size 96 Mormal size 96 dpi DPI settings normal size 96 DPI The 3 System Application Service Manual Program Installation ATTENTION In order to install the program on computers with the Windows NT Windows 2000 or Windows XP you must log in as user with administrator rights The is designed to work in Windows environment You will receive it on a CD ROM As soon as you insert the CD in your CD ROM drive the program will start automatically Otherwise run the instalator exe program provided on the CD ROM in the main directory and then select the language version As
25. r do not fill in field password Program main window will appear which contains the following push buttons MPC System Controllers Settings ie x Processes Download e PROCESSES Opens list of processes read out from controllers DOWNLOAD Allows for manual collected data readout from selected controllers 37 The 3 System Application Service Manual Device Chamber Operation Monitoring Program main window is showing active controllers later referred to as Device Status Monitor The window contains preview of devices controllers The following basic information will be displayed e device name e active program or STOP message e cycle number e information on current product MPC System Controllers Settings LA gt 13 41 42 Mil See Processes Download Indu WRC 2000 Program 1 Cycle 2 03 31 04 00 Administrator CHECKING FOR EMAIL E Point out selected controller with mouse indicator and click on it with left mouse key in order to obtain detailed information on the device status Window containing detailed information will appear Available information depends on controller type Windows for MCC 100 and e g INDU WRC 2000 controllers will look different Displayed information device name controller date and clock time controller program version active program or STOP message cycle number cycle name information on current p
26. roduct preset process parameters currently measured parameters status of device activation by the controller 38 The 3 System Application Service Manual Indu WRC 2000 Program 1 Product Readed D F Temp Chamber Temp Core Humidity cycle time WRC 2000 Cycle Step 2005 10 18 13 13 Outputs condition MIm RIGA 819 Identification Type Mame 0 000000 The illustration above applies to the INDU 2000 controller Receiving Collected Data from Controllers There are two ways for receiving collected data recordings from controllers The first one is automatic collected data receiving carried out 1 minute after initiating the MPC program and the second one manual collected data reception Manual collected data reception For all controllers it is always possible to receive collected data by pressing push button TRANSMISSION MPC System Controllers Settings Processes Download in program main window Window Collected data readout will appear 39 The 3 System Application Service Manual Transmision x Choose controller Ez TREREIHZEHMIZIOH Transmision Controller CH OMNI Progress bar Select or all controller from which collected data to be received and press push button TRANSMISSION Received collected data recordings is saved in database As soon as the
27. soon as the software has been installed the installation program will activate the Firebird database automatic setup Database Setup Firebird5OL n auppeorbng Firebird development 15 Setup Firebird Database Server 1 5 Installing Please wait while Setup installs Firebird Database Server 1 5 your computer Extracting files C Program FilessFirebirdsFirebird 1 readme tut Cancel The 3 System Application Service Manual If the message shown below is displayed setup AN An existing Firebird 1 5 Server is running You must clase the application or stop the service before continuing it means that the Firebird server has been previously installed In that case press OK and when the screen appears select Cancel and then in the dialog box Exit setup When the installation process is complete the program will be automatically activated Moreover the activating icon will be installed in the desktop name MPC and in the menu programs Start gt Programs gt Mikster gt MPC Main Screen MPC System 3 27 File Controllers Settings 08 55 18 Processes Download INDU WRC 2000 100 026 The 3 System Application Service Manual The MPC Program Main Menu The following items are available in the MPC application main menu e Login Logout e Service e Close t
28. the Program After activation the program inquires about USER By default after installation there are two users administrator marked with code Adm and operator with code mpc previous versions Oper both users have access without password When the program is activated for the first time enter user s code Adm do not enter password and press OK button If wrong data is entered message Wrong code or password will appear then press OK button and try again to enter user s code and password watch if entered letters have right size xi ser Adm Password Cancel Typical operations at first activation 1 Entering controllers list equipment list supported by the program 2 Entering users list and attributing passwords to them 3 Entering program parameters 4 Setting of proper parameters for graphs and printout parameters 5 Entering names of products and matching them identifiers Id or entering names and numbers of programs Adding and Modifying Controllers Supported by the Program Access to the controllers list is possible after logging in the program with administrator rights Select item Controllers settings in upper menu and then select Controllers list Window Controllers list will appear This window contains all entered controllers This is where we may add a new controller or change settings for already entered controller Click with mouse a in order to add new co
29. up Settings The MPC program is equipped with a built in tool to make security backups Set frequency for copy making everyday every week every month enter hour and determine the directory in which security backups will be saved Then confirm settings with push button OK x Frequency ale Every day Cancel Time Destination path Database Optimization The MPC program possesses built in mechanisms for database optimization The optimization process is executed on the server The MPC suggests optimization process execution once a day Should the MPC be activated at night between 3 00 and 7 00 a m the optimization will be executed automatically the MPC closes activates the optimization program and restarts as soon as the optimization is complete It is also possible to execute the database optimization process manually by selecting application Database Repair from menu Database repair While the database optimization process is in progress it is possible to use the MPC application on a regular basis at any workstation which is not a server The 3 System Application Service Manual MIKSTER optimalization v1 7 10 x Check whether the base contains errors errors are found proceed to Repair the base Repair of the If that process iz suspended for a long time E restart the computer and proceed to Advanced repair Create the copy of the current base
Download Pdf Manuals
Related Search
Related Contents
NEC DS1000 Telephone User Manual POSline SC2120 bar code reader Samsung C139STF Manual de Usuario 14204SL - Toro Media V7 Lamp for select Sony projectors Samsung P2450H Uživatelská přiručka SUUNTO AMBIT3 SPORT 2.0 Paris 11 - Université numérique Paris Ile-de Copyright © All rights reserved.
Failed to retrieve file