Home
User's guide - Applicaties Helpdesk Water
Contents
1. m location mwc n location nwe magnitude zeur u velocity zcuru v velocity zcurv 4 3 Constituent stations Quantity Array name station name nampol m location mpol n location npol constituents gro 4 4 Openings Quantity Array name station name namope m location kblm n location kbln start point of opening tidl tid2 end point of opening Many openings share the same name Therefor use the Getdata options i stands for index to extract the right opening Option i 1 will extract data of the first opening 4 5 Barriers Ouantity Array name station name nambar m location mbar n location nbar waterlevel left bottom basepa waterlevel top right basepb Version 1 4 November 2013 4 6 4 7 Histories for Linux users loss of energyheight waterlevel left bottom bavela waterlevel top right bavelb volume transports barq cbuv Barrier names are given for each line or point barrier The m n location are given for each point line barrier consists of one or more points Use the variable ibuv in order to find out which m n location belongs to a line or a point barrier See the LDS Flow documentation for more information Because all points of a line barrier share the same name Use the Getdata options i stands for index to extract the right point Option i 1 will extract the first barrier and in case of line barrier it will
2. Tfimona User s Guide Simona Workbook SIMONA report number 08 01 Rijkswaterstaat Ministerie van Infrastructuur en Milieu User s Guide Simona Workbook A tool for easily importing histories in Excel Version i 1 4 November 2013 Maintenance www helpdeskwater nl waqua Copyright Rijkswaterstaat User s Guide Simona Workbook Log sheet document Changes with respect to the previous version version 16 09 2008 Derived values added with screenshots 16 07 2010 Barrier Control added 11 10 2012 Simona 3835 if it is not possible to determine averages derived values print a minus sign in stead of zero 27 11 2013 Compatible with Excel2010 User s Guide Simona Workbook Contents 1 General directions for use of the Simona Workbook 2 2 Environment een 3 Zl Requirements 5 3 5 2 klin ia psi 3 2 2 Installations areas E ata aaa etcetera a 3 2 3 Security and permissions ie 3 3 Using Simona Workbook ssssccccccsssssssssssscscsssssssssssssessssssees 4 3 1 Starting the first time i 4 3 2 The Simona menu ii 4 3 3 Selecting Stations osissa ineen nnee o e liceale 6 3 4 Refinement and options rr asic dae dunn seek E E dere 7 3 5 Finish and write to Excel aa ia 9 4 Histories for Linux users ecsconssssssonsensonnnensensonssnensonsensonsnnennene 10 4 1 Waterlevel Stations i 10 4 2 Velocity stations aaa aaa aaa asas aaa aaa
3. In order to select more than one station use the shift or the control key The stations could also be sorted with the buttons right under the list As you can see in figure 3 2 you can sort Version 1 4 November 2013 6 3 4 Using Simona Workbook respectively at SDS file number station name m location or the n location In case of cross sections you could also sort at the direction After making the selection station quantity at the left side of the form you ll have to make it a little more definitive This can be done by bringing the selection to the right side of the form by pressing the button with the two arrows Now every selected station will be coupled to the selected guantities and these combinations will appear in the list at the right side of the form The order of that list is important because in the same order the series will be written to the Excel sheet You can reposition the items with the two arrows at the bottom of the form You can still add or deleting stations from the list After bringing the desired stations to the most right list and positioned them in the right order there are basically two options left The first option is pressing the Finish button This will close the form en write the data to Excel Default a column with time values will be written The output values are discussed in paragraph 3 5 The second option is to refine the results and press the Next button This will open a new form whic
4. extract data of the first point of the first line barrier Barrier Control Quantity Array name station name nambar m location mbar n location nbar time barrier state rrsbah dimension 1 prefered sill level rrsbah dimension 2 actual sill level rrsbah dimension 3 prefered gate level rrsbah dimension 4 actual gate level rrsbah dimension 5 prefered barrier width rrsbah dimension 6 actual barrier width rrsbah dimension 7 Use the option s to retrieve barriers by their name If the name is empty use the following format for the name NAMBAR xxxx Weirs Quantity Array name station name m location mweir n location nweir Version 1 4 November 2013 Histories for Linux users waterlevel left bottom whsepa waterlevel top right whsepb velocity left bottom whvela velocity top right whvelb volume transports whq loss of energyheight whde waterheights whh velocities whvel condition kwhend Weirs don t have names and the m n locations are not specifically stored for histories The variables mweir and nweir provide locations for all weirs as for the whole map Use the variable iaxwei as a translation table for locating the right m n locations See the LDS Flow documentation for more information The weirs have no names so use the Getdata options i
5. stands for index to extract weir data 4 8 Discharge cross sections Quantity Array name in the u direction v direction cross section name namtra namtrv m location s mit mitl mit2 n location s niti nit2 nitl momentum ctr ctrv cumalative fltr fltrv 4 9 Transport cross sections Quantity Array name in the u direction v direction cross section name namtra namtrv m location s mit mitl mit2 n location s nitl nit2 nitl total constituent adtr adtrv total advective atr atrv Version 1 4 November 2013 4 10 Histories for Linux users total diffusive mass dtr dtrv Sinks Sources Quantity Array name station name namdis m location mdis n location ndis discharge disch Version 1 4 November 2013
6. 10 4 3 Constituent Stations nascissi 11 AA of EA 11 HES BATES ee ERE 11 4 6 Baret Contoh Liki kiai sita basi aaa taika taika taika ba abi lant GUI 12 ATS WUS oss 55 agi RR REC RECRE CORE GERE CRE CCIE O RETE 12 4 8 Discharge cross Sections iii 13 4 9 Transport cross SectiOns iii 13 4 10 SINKS S OULCES enter an ze carica a nananana cet th ge 14 General directions for use of the Simona Workbook General directions for use of the Simona Workbook The Simona Workbook is an Excel template which is providing an easy way for importing time series in Excel It s most likely you even get significant results within ten mouse clicks The Simona Workbook can be opened with Excel The workbook adds an extra button and menu to Excel Excel2003 In Excel2010 the menu can be found in the Add Ins tab of Excel From the menu you can easily import all kinds of quantities like waterlevels currents barriers discharges at cross sections etc It s made very easy to compare series of multiple SDS files with each other The Simona Workbook gives you control over adjusting the timescale of the series layer selection It s also possible to generate a default chart add a column with time values and use date time instead of the time in minutes Version 1 4 November 2013 2 Environment 2 Environment For the Simona Workbook it is not necessary to set environment variables The workbook is completely indepen
7. 3 Discharge 10 Transport 11 Options 12 3 Figure 3 1 The Simona menu based on Excel2003 Every type of quantity has its one properties These properties will affect the behavior of the forms and the callings to Getdata which are discussed in the next two paragraphs Table 3 1 shows the properties for each quantity Quantity Layers Constituents Cross sections possible possible possible Waterlevel No No No Current Yes No No Constituent Yes Yes No Opening Yes No No Barrier No No No Barrier Control No No No Weir No No No Discharge No No Yes Transport No Yes Yes Sinks Sources Yes No No Table 3 1 Properties for each type of station At the menu you can select the quantity which you are interested in Every quantity opens basically the same form which is discussed in paragraph 3 3 Actually barriers could be given at a cross sections But Simona Workbook will convert the cross section to several points gt Barrier Control is a mix of point and cross sections but they are treated as point barriers Version 1 4 November 2013 3 3 Using Simona Workbook With the option button you can give the location to the Simona Installation again This may become handy if there s a new Simona Installation in the network Selecting stations After clicking one of the guantities from the menu a new form will appear An example is shown in figur
8. dent of any environment variable However there are still some issues which are discussed in this chapter 2 1 Reguirements Simona Workbook makes use of Getdata bat from the Simona installation Therefore Simona must be installed including all necessary third party applications like Perl Using the latest Simona installation is recommended Because the Simona Workbook is packed in an Excel template Microsoft Office Excel is also reguired The Simona Workbook is tested with Excel 2000 Excel 2003 and Excel2010 2 2 Installation The installation of the Simona Workbook is quite simple just use the Simona Installer which comes with the CD Make sure you enabled the installation of the Simona Workbook When you are using Simona in a network environment and you can t make use of the installer you could copy the Simona Workbook manual You have to copy the file simona workbook x1t from the etc directory to the default Microsoft Office template location In most cases this is the following location C Documents and Settings lt username gt Application Data Microsoft Excel XLSTART Be aware that the directory Application Data is default a hidden directory The easiest way going to this location is to open the start menu click on Run and then copy paste the location 2 3 Security and permissions Because the use of Getdata Simona Workbook needs the same permissions which are necessary for Simona Besides that it needs pe
9. e 3 2 In this example the user clicked the current button from the Simona menu The title also indicates the current buttons is pressed The first thing to do is adding a SDS file which is already done in figure 3 2 Adding a SDS file can be done with the button Add file As soon as the SDS file is loaded and de SDS file contains current stations all current stations will be listed under Available stations Select current stations step 1 2 Use stations from sdsfiles sds 1 C simona testfiles sdsfiles SD5 001 Remove Select stations Available quantities Stations to work with in Excel Cl magnitude Available stations Borgharen dorp 34 38 Borgharen Jul kar 52 23 24 00 26 180 22 00 26 140 23 00 35 161 21 00 18 122 20 00 22 107 19 00 22 93 18 00 14 78 17 00 15 64 16 00 31 38 15 00 43 16 14 00 37 2 sds naam m n a el Cancel Figure 3 2 Added the file SDS 001 Looking at the left side of figure 3 2 you ll see the quantities for current stations Below the quantities you ll see the available stations Every station begins with the numeric 1 This means that de station is related to sas 1 which can be found on top of the form After the numeric 1 comes the station name and at the end the m n location In case of cross sections you can also see the direction of the cross section namely the U or V direction Now a combination could be made of one or more quantities with one or more stations
10. ed At the lower part of the form the options frame you can toggle some extended options like e Writing a column with time values e Making automatically a default line chart e Convert the times which is given in minutes after the start of the simulation to a data time format e Writing derived values extremes average over 13 values at extreme peaks and average over 25 values at extreme peak If it is not possible to determine the average over 13 and or 25 values a minus sign will be printed in stead of zero When all changes are made you should click at the rinish button The form will disappear and the results will be written to Excel This will be further described in paragraph 3 5 Version 1 4 November 2013 8 3 5 Using Simona Workbook Finish and write to Excel After pressing Finish in the previous form the desired information will be written in the worksheet starting at the selected cell If enabled the first column is a column with time values After the column with times all selected stations in combination with their quantity will be written If multiple layers and or constituents are selected then they will be written next to each other Default all available layers or and constituents will be written unless the results where refined For each column a suitable header will be composed And if the date time option is selected all time values will be converted to the date time format even the times i
11. h is discussed in paragraph 3 4 Refinement and options After clicking finish in the previous form default all information about the stations will be written Sometimes this is not what is desired In order to refine the results click Next and the form of Figure 3 3 will show up The form is split up in two parts Use the upper part to refine the time series Here you can change the amount of layers constituents and the timescale Version 1 4 November 2013 7 Using Simona Workbook Refinement and options for current stations Refinement for each SDSfile les sds SDS 001 3600 v iles sds sD5 002 1 Change values Layers example 1 2 3 6 or 1 3 6 Starttime 0 Stoptime 3600 PIN The time interval is 0 25 minutes Options write Timeseries Derived quantities IV Column with timevalues Dateftime instead of minutes Generate default chart Previous Finish Figure 3 3 Refinement options for each SDS file The refinement in the upper part of the form applies only the selected SDS file If you want to refine another SDS files click the file you want to refine Now the values in the textboxes will update to the values applying for the SDS file you just clicked and you can refine the values While changing one of the values the app y button will be automatically highlighted Clicking on the app1y button makes the changes definitive So after clicking the apply button the list will be updat
12. ines In order to extract histories at Linux Getdata is improved with a new csv output format These comma separate values files could be opened with Calc from OpenOffice org This chapter is an explanation how Getdata could be use The general call for Getdata is Getdata pl f SDS file v variable name s station name k layer number if necessary l constituent number is necessary o csv output format For example if you want from SDS file SDS kustzuid3d the upper magnitude of station M Juliana type the following Getdata pl f SDS kustzuid3d v zcur M s M Juliana 1 1 o csv The result is a comma separated file which can be opened with OpenOffice at Linux The paragraphs in this chapter list tables with several variables use by the Simona Workbook These tables functionate as a quick reference guide for extracting histories for all kind of station or cross section data 4 1 Waterlevel stations Quantity Array name station name namwl m location mwl n location nwl waterlevels zwl 4 2 Velocity stations Quantity Array name station name namc De option s for station names doesn t apply for weirs barriers and openings These don t have unique names therefore you can use the option i that stands for index Option i 1 means the first station Version 1 4 November 2013 10 Histories for Linux users
13. n the optional chart Figure 3 4 shows an example of the output It shows a time column and the magnitude of the current for two stations with each two layers vertically E3 Microsoft Excel Simona Workbook 1 00 xit amp Eile Edit View Insert Format Tools Data Window Simona Help DSE SAY BMX n fe 2 M B 100 2 ara gjo BZ F1 zl A B C D E 1 time Krabbekreek magnitude layer Krabbekreek magnitude layer2 Rammegors magnitude layer Rammegors magnitude layer2 2 0 0 000 0 000 0 000 0 001 3 10 0 006 0 006 0 000 0 001 4 20 0 015 0 014 0 001 0 00 5 30 0 013 0 013 0 016 0 01 6 40 0 009 0 009 0 027 0 0 7 50 0 018 8 60 0 120 0 00 9 70 0 00 10 80 0 100 0 00 11 90 Krabbekreek 0 01 12 0 080 magnitude layer 13 s Krabbekreek 14 magnitude layer2 15 0 060 Rammegors 16 magnitude layert 17 0 040 Rammegors 18 magnitude layer2 19 0 020 20 Ei 0 000 2 D 20 40 60 80 100 Chart Area 24 Figure 3 4 Two stations with each two layers are shown in the chart Version 1 4 November 2013 9 Histories for Linux users 4 Histories for Linux users The Simona workbook is completely depending on Getdata output files All data extracted from SDS files for the Simona Workbook is achieved with several Getdata calls Sadly the Simona Workbook can t be used in combination with OpenOffice org so it couldn t be used on both Windows and Linux mach
14. rmission for writing to the registry If the Simona Workbook can t write to the registry it cannot store user settings but it will still work properly The security issue about running macro s in Excel is discussed in paragraph 3 1 Microsoft Excel 2000 is another name for Microsoft Excel 9 0 Version 1 4 November 2013 3 3 1 3 2 Using Simona Workbook Using Simona Workbook Starting the first time In Excel2010 go to File gt Options gt Customize Ribbon and select the Developer option In VB for Applications Alt F11 switch off Tools gt References MISSING RegistryWorx Enables VB VBA Friendly To make use of the Simona Workbook start Microsoft Excel as usual Then click at File and new in order to open a new workbook Office 2003 users and later should also click atthe on my computer link which appears at the right hand side after creating a new workbook You should now be able to select and open the Simona Workbook If that isn t the case take a close look at paragraph 2 2 The non Microsoft way of using the Simona Workbook is just to double click the template from the simona etc directory If you haven t made use of the Simona Installer to install the Simona workbook the workbook doesn t know the location of the Simona Installation So the first time opening the Simona Workbook it will ask for that location A new form will appear where the location to the Simona Installation
15. should be given for example c simona Simona2008_01 If the location to the Simona Installation remains valid you will never be asked again the value is stored in the Windows registry In order to change the location manually see paragraph 3 2 It may be that nothing happens when you open the Simona Workbook Most likely the security level is very high At this level Microsoft Excel denies every macro without asking It s completely safe to decrease the security level to medium Click on Tools Macro and security Then select the Security level medium Doing so Microsoft Excel will ask you to allow or deny potentially unsafe macro s Of course the Simona Workbook is completely safe so when opening the workbook again you could safely enable the macro inside the template The Simona menu If the installation has gone well you ll see a new Simona button next to the Help button see figure 3 1 Clicking on the Simona button will expand the menu It s a list with several guantities for stations and or cross sections it ends with the button options Version 1 4 November 2013 4 Using Simona Workbook B Microsoft Excel simona workbook1 HE File Edit View Insert Format Tools Data ImandrA Window Simona Help ARMEN PEPENE BENK AND MEN SAAN BAAN Dd or B AI f Current LA pee Oa a E F Constituent ee 2 L Opening E Sinks Sources 4 Barrier 5 A Barrier Control 7 Weir