Home
CRMX user guide
Contents
1. Each unit uses an indicator panel to control and report upon its operation See the operation section for details on how to link and unlink CRMX unts onn t press to link with or unlink from another unit Lock lit when keylock is locked Power lit when power applied e LumenRadio ignai strenginn indicator ot used on transmitters For receivers the amber indicator urns on at roughly 20 of maximum signal strength and he top green indicator turns on at roughly 90 The red indicator turns on only if a problem occurs with the link o the transmitter Connect Lock Power RF Link pmx RDM USB Ethernet Status indicator RF Link Indicator on when this unit is linked Receiver Flashes fast 3Hz if link is lost or when linking Transmitter Flashes fast 3Hz when linking or slow 1Hz when unlinking DMX On when a DMX signal is present RDM Flashes to show RDM packet activity USB On when connected via USB Ethernet Flashes to show ArtNet Streaming ACN activity Rear panel connections Dual CRMX transmitter unit Ethernet socket ArtNet St ACN etc also supports Power Over Ethernet a USB socket for future upgrades 5 pin male XLR socket DMX5 1 2A for port B Note If Power Over Ethernet is used do not also attach 12VDC or mains power Normal operation To link units 1 Ensure the antennas are connected on the front panels 2 Power
2. Set the subnet and universe for port A Set the IP address for the CRMX unit Set mode and protocol for portA T screw mounting Each CRMX unit is supplied with two Fscrews and nuts to allow it to be securely fixed to any mounting points such as trussing To use a T screw 1 Lower the Tscrew into the slot on the side of the unit and then twist it clockwise to lock 2 Place the rectangular nut onto the screw 3 Turn the nut clockwise until it tightens across the thus locking the T screw securely within the slot 4 You can now attach the unit to a secure mounting point The Fscrew is a size M8 bolt EU Declaration of Conformity CRMX RDM controller C Marking by the above symbol indicates CRMX RDM controller with instruc compliance with the Essential Requirements tions is available for download from of the R amp TTE Directive of the European Union LumenRadio com to be used with the 1999 5 EC This equipment meets the following RDM transmitters conformance standards EN 301 489 1 301 489 17 EN 300 328 1 EN 300 328 2 EN 609 50 Release 1 0b August 2009 LumenRadio AB Stena Center 1 S 412 92 Gothenburg Sweden www lumenradio com Phone 46 31 772 8084 Fax 46 31 772 8091 Email tech lumenradio com
3. on the transmitter and receiver s Ensure that the RF LINK indicators on all receivers are off use the unlink procedure if necessary 3 On the transmitter press and release the CONNECT button The transmitter will search for a period of ten seconds for unlinked receivers lts RF LINK indicator will flash At the end of the search period all located receivers will be linked to the transmitter their RF LINK indicators will be on 5 pin male XLR socket DMX512A for port A 12VDC power input Polarity is unimportant Single CRMX transmitter 85 264VAC or receiver unit power input 12VDC power input Polarity is unimportant 85 264VAC power input 5 pin XLR socket male on TX female on RX DMX5 12A input or output To unlink units e Unlink all Press and hold the CONNECT button on the trans mitter to unlink all of its receivers e Unlink one Press and hold the CONNECT button on a receiver to unlink it from a transmitter Art Net and Streaming ACN configuration The dual transmitter unit can process ArtNet and Streaming ACN signals via its Ethernet connection Using the Sand Device Browser utility on a computer linked to the same network as the CRMX unit you can determine how signals should be directed and used The two CRMX ports operate independently each port can be fed from or to any of 256 specific universes via the Ethernet con nection The CRMX unit can act as a converter between ArtNet Streaming ACN and the w
4. CRMX user guide e LumenRadio Lighting control via wireless is nothing new there are plenty of options Trouble is everyone is using the same narrow band of frequencies and not just for lighting Your competition are wireless microphones in ear monitors Wi Fi ZigBee Bluetooth devices and many more often at the same time To achieve true wireless link reliability you need an ingenious approach CRMX Cognitive Radio MultipleXer provides the answer Using our Cognitive Coexistence system at its heart CRMX continually monitors the whole frequency band to iden tify all problem areas and dynamically shifts its operation The result is that CRMX neither disturbs nor is disturbed by other systems it totally coexists even in the most crowded areas CRMX units use high frame refresh rates and intelligent error correction routines to fix problems before they ever become apparent CRMX units are so efficient that they can repair most corrupted or mistimed inputs from other devices a kind of DMX washing machine to clean up dirty signals CRMX units are available as single transmitters and receivers which support DMX 512A RDM or as a dual transmitter which can send two DMX RDM universes and additionally supports ArtNet and Streaming ACN via its Ethernet connection As a useful bonus the dual unit can also convert between Art Net Streaming ACN and standard DMX RDM via the wireless and wired connections
5. ired and or wireless DMX connections To configure Art Net and streaming ACN dual units only 1 Run the Sand Device Browser utility from LumenRadio com on a computer linked to the same network as the CRMX unit If there are two or more CRMX units right click on one of the _t entries in the utility and click the Identify option The associated CRMX unit will flash its indicators to identify itself 2 If necessary change the default Ip address of the CRMX unit If WV gg 64 O Ip is changed double click on the Ip address window to reset the unit or power cycle the unit to achieve the same result Disabled Normal DMX In Signal DMX Out Signal 3 For each CRMX port choose the Mode see panel right and operation only from XIR socket from Ethernet ihe appropriate Protocol ArNet of Streaming ACN between the XLR is sent to Ethernet socket is sent to pprop l g l socket and the socket as well as XLR socket and 4 Choose the required Subnet 1 to 16 and the appropriate wireless output wireless output wireless output DMX Universe 1 to 16 within that subnet ig Sand Device Browser 1 1 0 0 About Name Mac Ip Firmware Status 1 Mode 1 Protocol 1 Sub 1 Univ 2 Mode 2 Protocol 2 Sub 2 Univ Ow CRMX TX2 00 30 192 168 0 162 2 1 0 0 Alive DMX Out Art Net 0 1 DMX Out Streaming ACN 0 1 Set the subnet and universe for port B Set mode and protocol for port B