Home

Minisensor2 User guide

image

Contents

1. change without notice For more information visit our website www helvar com Minisensor2 user guide F13 102 1D 05 06 Last level function dere e Simultaneously press amp hold 4 amp W for 10 seconds N bZ e The operation is confirmed by flashing the lamps A O CA e e f last level function is enabled the lights will turn on to the level they e3 ae f i e were at before mains interruption failure or mains switch Lights that v A were off will remain off e Last level function is deactivated by carrying out Initial configuration I Test mode This mode should only be used to test the functionality during installation In Test mode PIR delay times are 10 times faster and the constant light response time is 10 times quicker than in normal operation and should only be used for demonstration or test purposes mee e Enable Simultaneously press amp hold 4 amp AX for 10 seconds b The operation is confirmed by flashing the lamps twice A yr 4 e Disable Simultaneously press amp hold 4 amp A for 10 seconds ea The operation is confirmed by flashing the lamps o e3 e Test mode is returned to normal mode by turning power off and b OA on again you can use e g Switch Control to reset the Minisensor2 both channels at the same time e Test mode is also returned to normal mode automatically after a delay of 10 min e Test mode is also returned to normal mode by
2. Helvar D ee m f F13 102 1D 05 06 N e Minisensor2 User guide lighting the way forward Minisensor2 user guide F13 102 1D 05 06 Introduction The Helvar Minisensor2 is a two channel luminaire mounted component containing three integrated sensors e Presence detector PIR e Constant light sensor e Infrared IR receiver The two separate channels A amp B enable scene setting amp lighting control The constant light sensor only adjusts the output from channel A where presence detection amp infrared control affect both channels The Minisensor2 is only compatible with the Helvar EL si electronic DALI ballast range Sensor set up amp programming is achieved using the Helvar DIGIDIM infrared remote control Reception areas Presence detector PIR Orientation PIR 3 0m NEGI 4 5m Infrared IR control Constant light sensor pipe version 150 5 0m 3 0m lt 5 0m gt Z foam NV Sl ie anes ee gt 7 0m gt Out of box operation Upon first application of power the Minisensor2 operates according to the programmed memory of the EL si ballast If the ballast has no program then the IR buttons A W and 0 1 On Off will be active Channel control is also active This allows the control of channels A amp B please see section IR control for more information To program default scenes 1 4 and to activate fu
3. ht feature e lf multiple sensors are installed care should be taken to ensure the sensing areas of the minisensors do not cross and interfere with each other e Only connect the Minisensor2 to the DIGIDIM input of a Helvar EL si ballast e The Minisensor2 cannot be connected to the DALI interface Data subject to change without notice For more information visit our website www helvar com 5 Minisensor2 user guide F13 102 1D 05 06 Technical spesifications Constant light sensor Reception area 100 Measuring range 100 1500 lux IR receiver Frequency 86kHz Presence detector Detection area 4 5 x 3 0m mounting height 3 0m Electric data Internal communication with Helvar EL si electronic ballast Operation conditions Ambient temperature range 0 C to 50 C Storage temperature range 10 C to 70 C Relative humidity 90 max non condensing Dimensions Conformity amp Standards Safety Only valid if sensor is mounted in the same fitting as the ballasts Safety EN61347 2 11 EN61347 1 EN60598 1 IP rating 21 Electric strength 1 5kV Finishing Thermoplastic Protection Single insulation Wire length Max from Minisensor2 to furthest ballast 15m Note e The Minisensor2 is not designed for installation outside of a luminaire Connection Up to 4 ballasts per Minisensor2 Connection combinations are found from the following table Lead color Yel BI Gr Rd Example connecti
4. ight level is not affected by switching the lights off e Manual ON Automatic OFF feature PIR will not switch the lights on when movement is detected but will switch them off if no movement is detected e Regardless of other light level commands e g changes in the constant light level an enabled PIR will switch the lights to the PIR OFF scene if no movement is detected within its programmed delay time Infrared IR control C A 0 1 ON OFF key Toggles the lighting between 100 and OFF B 1 2 3 or 4 key Recall of stored scene or preset level for the selected key C A key Single push B e Switches channel A amp B on to minimumif lights were off e Steps up channel A amp B by one step if lights were on Press amp hold A e Dims up channel A amp B from minimum if lights were off e Dims up channel A amp B from last level if lights were on D W key Single push D e Steps down channel A amp B by one step if lights were on Press amp hold e Dims down channel A amp B from last level if lights were on If constant light has been selected and programmed the Minisensor2 will dim the lights to the programmed constant light level Modify and store scenes channel A amp B e Simultaneously press amp hold 1 amp he or A 4 to raise or lower the light level of channel A to the desired level e Simultaneously press amp hold 2 a
5. mp or W to raise or lower the light level of channel B to the desired level e Press amp hold for 10 seconds the desired remote control scene button 1 2 3 or 4 where you would like the scene to be stored e The operation is confirmed by flashing the lamps e Repeat the above for other scenes buttons 1 2 3 or 4 Notes e Scene is a combination of light levels of channel A and B that can be recalled by the press of a button e Storing scenes on buttons 1 2 3 or 4 will replace any previously stored light levels Data subject to change without notice For more information visit our website www helvar com 3 Minisensor2 user guide F13 102 1D 05 06 Optional functions programming Select the operating modes by pressing the below mentioned button combination for about 10seconds The product confirms the succesful programming by flashing the lamps Presence detector PIR Light level Light level ON LOW OFF t OFF t PIR LOW delay IPIR OFF delay PIR LOW delay PIR OFF delay Standard PIR delay funtionality Corridor storage room functionality Set PIR ON scene D Select the overall desired light level See Infrared IR control section w C o o2 e Simultaneously press amp hold 0 1 for 10 seconds 7 e3 e The operation is confirmed by flashing the lamps v 0 1 Set PIR LOW scene i RZ Selec
6. on Ch A 2pcs Ch B 1pcs SWITCH CONTROL optional Potorty fele ballasts Helvar i O DIGIDIM ot ElL si x SWITCH CONTROL optional 358 9 56 541 44 1322 222211 46 303 24 69 50 l 39 02 55 30 10 33 D 49 6074 92 090 Data subject to change without notice For more information visit our website www helvar com
7. pressing preset buttons for 10 sec O T 1 O T 2 0 1 3 or O 1 4 This will also change the functionality to selected mode Programming of IR channel This allows multiple remotes to work in same area without affecting each others e Set the rotary switch of the remote control in battery compartment to an address group 0 F All minisensors will respond to DIGIDIM remote controls set to address 0 or D If more than one remote control will be used to control different minisensors in the same area the remote controls must be addressed to different groups 1 9 A B C E or F The Minisensor2 will then respond to its corresponding remote control only e Always point the remote control directly at the Minisensor2 to be configured Take care that no other minisensor is in the IR reception area unless they are supposed to belong to the same address e Point at the Minisensor2 to be addressed and press 3 amp 4 for 10 seconds or until lights flash Recommendations e First choose the basic mode by 0 1 1 4 e Then choose any additional functionality Delay time PIR levels and power on to last level e Ensure that the Minisensor2 is located out of view of direct light to ensure correct operation of the constant light sensor and IR e Position the Minisensor2 in a area of combined natural artificial light for best operation of the constant lig
8. rther features please see the Initial configuration section for more information Use the Helvar DIGIDIM infrared remote control for configuration 2 Data subject to change without notice For more information visit our website www helvar com Minisensor2 user guide F13 102 1D 05 06 Initial configuration default settings Select the operating modes by pressing the below mentioned button combination for about 10 seconds The product confirms the succesful programming by flashing the lamps 0 1 1 Presence detector PIR delay times 15min 20s PIR on 100 Power on 100 0 1 2 PIR 15min 20s Manual On Auto Off Power on 100 0 1 3 x 0 1 PIR 15min 20s PIR on 100 Constant light Power on 100 Helvar 0 1 4 PIR 15min 20s Manual On Auto Off Constant light Power on 100 Dim the lights to desired constant light level before selecting the operating mode Default values for operating modes Scene 1 100 PIR LOW delay 15 min Scene 2 75 PIR OFF delay 20 sec Scene 3 50 PIR Exit delay 15 min Scene 4 25 Power ON level 100 PIR ON light level 100 Fade time 1 0 sec PIR LOW light level 1 PIR OFF light level 0 Notes e Only the light level of channel A will vary in order to try to keep the stored overall constant light level e Constant light will not switch lighting on or off e The stored constant light level is not affected by the PIR e The stored constant l
9. t the overall desired light level See Infrared IR control section L O e Z e Simultaneously press amp hold 0 1 amp for 10 seconds 5 e3 e The operation is confirmed by flashing the lamps v Set PIR OFF scene D Select the overall desired light level See Infrared IR control section el a C7 o7 e Simultaneously press amp hold 0 1 amp W for 10 seconds 24 e The operation is confirmed by flashing the lamps J Y z0 1 PIR delay time setting a2 Standard PIR delay functionality with 30min delay to PIR LOW scene el E and 20s delay to PIR OFF scene A O O e Simultaneously press amp hold 3 amp for 10 seconds 2 o4 e The operation is confirmed by flashing the lamps e v 0 1 2 Corridor storage room functionality with 1min delay to PIR LOW el TO scene and 30min delay to PIR OFF scene A Co e Simultaneously press amp hold 3 amp A 4 for 10 seconds l d e4 e The operation is confirmed by flashing the lamps e3 0 1 Notes e Regardless of other light level commands e g changes in the constant light level an enabled PIR will switch the lights to the PIR OFF scene if no movement is detected within its programmed delay time e PIR scenes can be any combination of light levels of channels A amp B e If you manually turn lights off you might have to manually switch them on PIR will not switch lights on until PIR LOW delay PIR Exit delay 4 Data subject to