        Operating instructions OSRAM OUTDOOR sensor
         Contents
1. OSRAM    OUTDOOR       Light and motion sensor  Operating instructions    XII 2009  OUTDOOR_ba0912en_we1 02 indd    OSRAM GmbH  Kunden Service Center  Customer Service Center  CSC     Steinerne Furt 62  86167 Augsburg  Germany    Tel    49  0  1803 677   200   kostenpflichtig   charges apply   Fax    49  0  1803 677   202    www osram com    www osram de    4008321957061                Description   Purpose and application    The OUTDOOR sensor detects the presence of persons and  measures the intensity of ambient light     It is ideally suited for indoor and outdoor light applications that  require a high level of protection against outdoor weather condi   tions  wetness  dirt      The sensor is designed for wall and ceiling installation     Function    The sensor works fully automatically and is used for contact   free switching  The values detected by the sensor  motion   light value  control the switching behaviour on the basis of the  settings created by the user     The following settings can be made   e Delay  if no motion is detected    e Light switching threshold   e Operating mode    Design    The sensor is made up of the following components    e Light and motion sensor with an integrated LED  A   e Buttons S1 and S2  B    e Swivel arm  C    e Connection box  D     Operation Initial startup    During initial startup  the initialisation for the functional check  and sensor calibration is started     e The luminaires are switched on for approx  2 s     e The red LED 
2. inside the lens flashes until the sensor  automatically switches to test mode after max  45 s  see     Executing the test mode        e After the test mode is ended  the sensor switches to normal  mode  see    Operating modes      Operating modes    Normal operation    After initial startup or a reset  the sensor goes into normal mode  for light  and motion dependent switching  with the following  default settings     e Light switching threshold  7 lux   e Delay  2 minutes   The default settings can then be changed individually   Reset       Press buttons S1 and S2 simultaneously for at least 6 s       Confirmation  The LED flashes 2x     Pulse mode    The pulse mode is available with a fixed delay for controlling ex   ternal time switches  see  Activating deactivating pulse mode        Page 1 of 4    Operation  cont      S1             S2    Control principle  normal mode     Luminaire  OFF        Artificial light required     yes  Luminaire  ON    i         Luminaire       af     5 s   30 min    p Luminaire  no OFF       Luminaire       Artificial light required   no    Vv    oi    Setting the light switching theshold    Setting of the light switching threshold at which the load is  switched on or off as a function of the measured light value   default setting  7 lux      If the light switching threshold is deactivated  the connected  load is switched on whenever motion is detected  independent  of the measured light value     Changing the light switching threshold    Q Pre
3. ram    in the fitting instructions     The device is functional  but the switching functions are  not being carried out    Is the initialisation process finished  See    Performing an  initialisation       Is the light switching threshold set correctly  See    Setting the  light switching threshold      Is the detection area set correctly  See  Setting the detection  area    in the fitting instructions     Is the correct operating mode  normal mode pulse mode  set   See    Normal mode and reset    and   Activating deactivating the  pulse mode        Page 3 of 4    Appendix Technical data    Operating voltage 230 V AC 50 60 Hz    Switch output load capacity Incandescent lamp  2300 W  HV halogen lamps  1500 W  Fluorescent lamps  1000 VA    Inductive load  600 VA    Max  number of ECGs     5x QT FQ 2x80 or  QTP5 1x80 or  QTP5 2x54   7X QTP5 2x14 35 or  QTP5 1x54   9x QTP5 1x14 35   5x QTP8 2x58   9x QTP8 1x58   5x QT FIT8 2x58 or  QT FIT8 2x36   9x QT FIT8 1x58 or  QT FIT8 1x36   5x QTi 2x35 49 80    10x QTi 2x28 54    14x QTi 1x28 54     30   C     70   C  Protection type IP 55       Operating temperature    Dimensioned drawing    f4mm       10mm         6mm      The Low Voltage Directive has been complied with according to  EN 60669 2 1     Conformity with the relevant EU directives is  confirmed by the CE symbol     Page 4 of 4    
4. ss button S1 briefly  The current light value measurement  is stored as the light switching threshold       Confirmation  The LED flashes 1x   Deactivating activating the light switching threshold     Press button S1 for at least 2 s       Confirmation  The LED flashes 2x     When the light switching threshold is deactivated  the LED  flashes briefly every 5 s     Setting the delay    The switch off delay time in normal mode when no motion is  detected  default setting  2 min        Press button S2 briefly  The LED begins flashing        Press button S2 again briefly after a delay of T  5 s      30 min   The LED goes out  T is stored as the delay time     Page 2 of 4    Operation  cont      Activating deactivating the pulse mode    The pulse mode enables the control of external time switches   such as stairwell time switches   When the light value drops  below the light switching threshold and motion is detected   the luminaires are switched on for 1 s and motion detection is  deactivated for 9 s       Press button S2 for at least 2 s     Confirmation  The LED flashes 2x     Executing the test mode    checking motion detection    In the test mode  the parameters are optimised for a rapid  check of the motion detection  When motion is detected  the    luminaires are switched on for 1 s and then switched off for 2 s   The light switching threshold is deactivated     Note  During initial startup  the test mode is automatically  started after initialisation       To start the tes
5. t mode  Simultaneously press buttons S1 and  S2 for 3     5 s  until the LED lights up continuously        Confirmation  The LED flashes 2x       Check the motion detection and adjust the detection area if  necessary  see the fitting instructions       The test mode is ended automatically after 10 min  To end  the test mode earlier  Press button S1 or S2 briefly     Switching luminaires manually  Precondition  Normal mode  the pushbutton switch is connected   see the connection diagram in the fitting instructions   To switch on   e For the duration of delay T     Press the pushbutton switch briefly    2  Confirmation  The LED lights up continuously     e For 4 hours  Press the pushbutton switch 2x briefly   To switch off  Press the pushbutton switch briefly     Manual initialisation    The initialisation is used for the functional check and sensor  calibration     Precondition  Normal mode  the pushbutton switch is connected   see the connection diagram in the fitting instructions     Press the pushbutton switch for at least 2 s       Confirmation  The luminaires are switched on for 2 s and the  LED flashes for max  45 s     Note  The initialisation is performed automatically during initial  startup or after every power failure of at least 3 s     Troubleshooting    If you cannot remedy the fault  please contact the customer  service department of the manufacturer     The device is not functional    Is there power and is the device connected correctly  See     Connection diag
    