MOVITRAC® B Safe Disconnection - Conditions - SEW

image

Contents

1. Connection Variants Refer to the publication Safe Disconnection for MOVITRAC B Applications for examples of approved connection variants of units listed in the section Approved Units for safe disconnection of the drive according to stop category 0 or 1 of EN 60204 1 and fail safe protection against restart according to EN 1037 and fulfillment of the safety category according to EN 954 1 or performance level d of EN ISO 13849 1 The publication Safe Disconnection for MOVITRAC B Applications is constantly being supplemented by possible applications The publication includes checklists which offer additional assistance in project planning and installation as well as operating MOVITRAC B drives in safety oriented applications It is essential that you comply with the publications listed in the section Safety and warning instructions for all the connection variants listed in the publication Safe Disconnection for MOVITRAC B Applications Safe Disconnection Manual Conditions MOVITRAC B Index Index A Approved devices ssssssssesese 10 MOVIDRIVE9 MDX60B 61B AC 380 500 V 10 C Connection variants ssssssssssss 14 D Drive Coasting note 10 E Emergency stop relays external 12 Requirements
2. ri E aaa 14 DI c 15 Safe Disconnection Manual Conditions MOVITRAC B Important Notes Safety and warning notes 1 Important Notes 1 1 Safety and warning notes Always observe the safety and warning notes in this documentation Electrical hazard Possible consequences Severe or fatal injuries Hazard Possible consequences Severe or fatal injuries Hazardous situation Possible consequences Slight or minor injuries Harmful situation Possible consequences Damage to the unit and the environment Tips and useful information LO gt eE 1 2 Contents of this manual This document contains safety related addendums and conditions for the operation of MOVITRAC B with safe disconnection of the drive according to stop category 0 or 1 according to EN 60204 1 and fail safe protection against restart according to EN 1037 and conformance with safety category 3 according to EN 954 1 It also describes the operation of MOVITRAC B with safe disconnection of the drive according to stop category 0 or 1 to EN 60204 1 fail safe protection against restart according to EN 1037 and fulfillment of performance level d according to EN ISO 13849 1 This document supplements the MOVITRAC B operating instructions and limits the application notes according to the following information It may only be used in con junction with the MOVITRAC B operating instructions Safe Disconnection Manual Conditions MOVITRAC B
3. Gearmotors Industrial Gear Units Drive Electronics Drive Automation Services UMANE NNNM d fa y Bo MOVITRAC B Safe Disconnection Conditions Edition 06 2007 M 11469013 EN anual SEW EURODRIVE Driving the world E ey sam d 7 mr MU E e Se oue Vt a jui ON Contents 1 Important Notes 5 eter ESHETER lend canenevnnaadeesencuederseeteesacete 4 1 4 Safety and warning notes sss eem 4 1 2 Contents of this 4 2 Safety Concept aiiin ertt tl nene XR Per kx exe tea a na ne rue 5 2 1 Restrictions in recipe en Bede gc nea hd ne 6 2 2 Representation of the safety concept for MOVITRAC B control unit 7 2 3 Representation of the safety concept for MOVITRAC B size 0 8 3 Safety Requirements esee eene enne nnne nennen nnne 9 3 1 Notes on stop categories ssssssssseeee eene 9 3 2 Approved devices sssssssssssseeneee emnes 10 3 3 Installation requirements sssssssssssesseeeeen es 11 3 4 Requirements for external safety switching devices 12 3 5 13 3 6 X Operation requirements c ccceecceceeeeeeeeeeeececeaecaeeeeeeeeeeeeeteeesenaees 13 4 Technical A RR 14 5 Connection Variants orsin esearon r aaa eea aaa
4. 12 Sample circuit sss 13 Switching capacity sse 12 Important notes 4 Installation Notes on routing control leads 11 Permitted terminal connections 11 Requirements sssssssssseeeeee 11 Safe Disconnection Manual Conditions MOVITRAC B Operation requirements 13 R Requirements External emergency stop relays 12 Installation sss 11 Operation eerte eee oett 13 SLATED EE 13 S Safety concept 5 Restrictions ai a a aaar aaiae 6 Schematic representation 7 8 Safety notes solea ea 4 Safety requirements sss 9 Startup requirements 13 Stop categories notes sss 9 15 Gearmotors Industrial Gear Units Drive Electronics Drive Automation Services How we re driving the world With people who think fast and With a worldwide With drives and controls develop the service network that is that automatically future with you always close at hand improve your productivity With a global presence With innovative that offers responsive technology that solves and reliable solutions tomorrow s problems Anywhere today E
5. Safety Concept 2 Safety Concept In case of danger any potential risk to a machine must be eliminated as quickly as possible Dangerous movements can generally be bringing the unit to standstill and applying restart prevention MOVITRAC B is characterized by the optional connection of X17 to an external fail safe prototype tested emergency stop relay The emergency stop relay disconnects all active elements disconnection of the safety oriented 24 V power supply of the output stage control that generate the pulse trains to the power output stage IGBT when a connected control device E STOP button with latching function is activated Disconnecting the 24 V voltage supply at connector X17 ensures that the supply volt ages required for operating the frequency inverter and consequently for generating a rotating field of pulse patterns which allow the generation of a rotating field are safely interrupted preventing automatic restart Instead of separating the drive galvanically from the power supply using contactors or switches the disconnection procedure described here prevents the power semi conductors in the frequency inverter from being activated thus ensuring safe discon nection This process disconnects the rotating field generation for the respective motor The individual motor cannot develop any torque in this state even though the mains voltage is still present The requirements for the safety control are clearly def
6. be disconnected Safe Disconnection Manual Conditions MOVITRAC B Safety Concept Representation of the safety concept for MOVITRAC B control unit 2 2 Representation of the safety concept for MOVITRA C B control unit 1 Emergency stop relay B 1 external pU UU rnal N 24v Safe disconnection 2 N with one pole or approved for cat 3 Uz l external two poles acc to EN 954 1 acd MAIZE phu locu GND AT prn p 9 J PL d EN 13849 1 i NT 9 Y SN l OHV l 8 ANV E I MOVITRAC B 9 l 2 l l o l E CAN o RS485 l Binary 5 Voltage supply for l LERNEN ooo Pm 4 contlofthe T r Voltage supply for output stage control O K d powertransistors l Computer Ure scc not in the safety circuit f js l Binary coe OOO a OUT l I 24 V safety disconnected brake applied not in safety circuit Connection plug for power section Analog IN 5 e nrw l l 8 l 2 E Temperature S l measuring 3 5 9 Power section AUD bea e eee 3 1 Emergency stop relay external 2 Low voltage switc
7. category 0 or 1 in accordance with EN 60204 1 and fail safe protection against restart according to EN 954 1 safety category 3 or performance level d according to EN ISO 13849 1 The shielded lines of the safety oriented 24 V voltage supply terminal X17 must be clamped under the signaling electronics shield clamp You must observe the technical data of MOVITRAC B MOVITRAC B operating instructions Removing jumpers Requirements for external safety switching devices If the requirements of the standard EN 954 1 are to be met at least one approval for safety category 3 according to EN 954 1 must be available If the requirements of the standard EN ISO 13849 1 are to be met at least one approval for performance level d according to EN ISO 13849 1 must be available If the DC 24 V link voltage is safely disconnected at the positive pole only no test pulses must be applied to this pole in disconnected condition Bipolar disconnection of the DC 24 V supply is permitted The values specified for the safety switching devices must be adhered to when designing the circuit The switching capacity of the emergency stop relay must correspond at least to the maximum permitted limited output current of the DC 24 V voltage supply Observe the manufacturer s instructions of the emergency stop relay concerning the permitted contact load and required fusing for emergency stop relays If the manufacturer provides no specific
8. information on this issue the contacts must be protected with 0 6 times the nominal value of the maximum contact rating specified by the manufacturer The controller must be designed and connected in such a way that resetting the control unit itself will not lead to a restart A restart may only be carried out after an additional reset of the controller Safe Disconnection Manual Conditions MOVITRAC B Safety Requirements Startup requirements 3 4 4 Emergency stop relay sample circuit The following figure shows the basic interface of an external emergency stop relay according to the before mentioned requirements to MOVITRAC B The information in the respective manufacturer s data sheets must be observed for connection 1 pole disconnection of the 24 V supply voltage Approved EMERGENCY STOP actuator element Emergency stop relay with certification for at least Fuses in accordance with category 3 according to the manufacturer EN 954 1 or performance specifications of the level d according to emergency stop relay EN ISO 13849 24 V Ode Ls Safety oriented 24 V supply 24 V voltage supply of the emergency stop relay X e g GND E Reset button 3 5 Startup requirements Startup must be documented and the functionality of the safety functions proven Startup checks of the disconnecting device and the correct wiring must be perf
9. take addi tional protective measures for example movable covers with closure which cover the hazardous area until persons are no longer in danger The additional protective covers must be designed and integrated in such a way that they meet the safety category required for the machine After activating the stop command access to the machine must remain blocked until the drive has reached standstill or the access time has to be determined to ensure that an adequate safety distance is maintained Safe Disconnection Manual Conditions MOVITRAC B Safety Requirements Installation requirements 3 3 Installation requirements Note the following instructions for applications of MOVITRAC B with safe disconnec tion of the drive according to stop category 0 or 1 according to EN 60204 1 and fail safe protection against restart according to EN 954 1 safety category 3 or performance level d according to EN ISO 13849 1 The line between the safety control system or the safety oriented tripping device and MOVITRAC B terminal X17 is designated as the safety oriented 24 V voltage supply Power lines and the safety oriented 24 V supply voltage must be installed in separate cable ducts The safety oriented 24 V supply voltage must be routed according to EMC guidelines and as follows Outside an electrical installation space Shielded cables must be routed perma nently fixed and protected against external damage or ot
10. core N te Ec OUT I 24V safety Analog IN e n Temperature measuring l l 1 Emergency stop relay external 2 Low voltage switched mode power supply 3 Safety switched mode power supply SNT 4 Voltage supply for control of power transistors 5 Feedback to the computer core Voltage supply for output stage control O K not in the safety circuit 6 Pulse width modulated signals for the output stage 7 Power section 8 Motor For units of size 0 in design MCO7B SO an external 24 V supply must always be con nected as the control electronics can only be powered in this way Safe Disconnection Manual Conditions MOVITRAC B Safety Requirements Notes on stop categories 3 Safety Requirements The following conditions are mandatory for the installation and operation of MOVITRAC B in applications with safe disconnection of the drive in accordance with category 0 or 1 of EN 60204 1 and fail safe protection against restart according to EN 1037 and conformance with safety category 3 of EN 954 1 or performance level d of EN ISO 13849 1 The requirements are divided into the following sections Approved devices Installation requirements Requirements for external safety switching devices Startup requirements Operation requirements 3 1 Notes on stop categories Stop category 0 means that the safety 24 V voltage supply can be disconnected inde pendent of the
11. hed mode power supply 3 Safety switched mode power supply SNT 4 Voltage supply for control of power transistors 5 Feedback to the computer core Voltage supply for output stage control O K not in the safety circuit 6 Pulse width modulated signals for the output stage 7 Power section 8 Motor 9 High voltage switched mode power supply Safe Disconnection Manual Conditions MOVITRAC B Safety Concept Representation of the safety concept for MOVITRAC B size 0 2 3 Representation of the safety concept for MOVITRA C B size 0 n Emergency stop relay A 1 external ay tae COM LAV Safe disconnection IN 24 external with one pole or approved for cat 3 F external P two poles acc to EN 954 1 To externa g GND or Sy A o a PL d EN 13849 1 SS m e SNF dudes MoviTrac B wy O in t IN SNT N fs SS l o E l 2 e e l E mmm CAN o RS485 a 0 M 5 1 1 Voltage supply for A 4 a control ofthe T Voltage supply for output stage control O K _ powertransistors i Computer N not in the safety circuit Binary
12. her equivalent measures Individual conductors can be routed inside an electrical installation space Observe the respective regulations governing the application It must be ensured that parasitic voltages cannot be generated in the safety oriented 24 V supply voltage The total cable length between the safety control system e g safety switching device and MOVITRAC B is limited to a maximum length of 100 m for EMC reasons The switching capacity of the emergency stop relay and the maximum permissible voltage drop on the 24 V supply cable must be observed during disconnection of group drives Only use terminal connections terminal blocks that meet EN 60204 1 and prevent short circuits Observe the notes in the MOVITRAC B operating instructions on EMC compliant cabling It is essential that you apply the shielding at both ends on the housing Only use power supplies with safe isolation SELV PELV according to VDEO10 According to EN 60950 1 the voltage between the outputs or between any output and a ground part must not exceed DC 60 V voltage for longer than 0 2 s after only one fault The maximum DC voltage must be 120 V Safe Disconnection Manual Conditions MOVITRAC B 11 12 3 4 Safety Requirements Requirements for external safety switching devices You must remove the jumpers at X17 1 to X17 4 following figure for use in appli cations with safe disconnection of the drive according to stop
13. ined in the following sections and must be observed Using a suitable external circuit via a safety control with approval to at least EN 954 1 category 3 enables operation of the MOVITRAC B frequency inverter with safe disconnec tion to stop category 0 or 1 according to EN 60204 1 fail safe protection against restart according to EN 1037 and fulfillment of safety category 3 to EN 954 1 Using a suitable external circuit via a safety control with approval for EN ISO 13849 1 performance level d enables operation of the MOVITRAC B frequency inverter with safe disconnec tion according to stop category 0 or 1 to EN 60204 1 fail safe protection against restart according to EN 1037 and fulfillment of performance level d to EN ISO 13849 1 Safe Disconnection Manual Conditions MOVITRAC B Safety Concept Restrictions 2 1 Restrictions Important The safety concept is only suitable for performing mechanical work on the system machine components Caution A system machine specific risk analysis must be provided by the system machine manufacturer and taken into account for the use of the MOVITRAC B frequency inverter Danger of fatal injury When the safety oriented 24 V voltage supply is discon nected the mains supply voltage is still present at the frequency inverter DC link Caution If work is carried out on the electrical section of the drive system the DC link voltage must
14. ormed and documented for MOVITRAC B with safe disconnection of the drive according to stop category 0 or 1 of EN 60204 1 fail safe protection against restart according to EN 1037 and compliance with safety category 3 according to EN 954 1 or perfor mance level d according to EN ISO 13849 1 At startup the safety related 24 V control voltage must be included in the functional test 3 6 Operation requirements Operation is only allowed within the limits specified in the data sheets This applies both to the external emergency stop relay as well as MOVITRAC B The safety functions must be checked at regular intervals to ensure perfect working order The period of time between the tests should be specified in accordance with the risk analysis Safe Disconnection Manual Conditions MOVITRAC B 13 14 4 5 Technical Data Technical Data X17 safety input terminal 4 Voltage Cross Section Time Min Type Max Unit Safety oriented 24 V supply voltage 19 2 24 30 DCV Power consumption size capacity Size 0 27 uF 3 Size 1 270 uF 5 Size 2 28 270 uF 6 Size 3 270 uF 7 5 Size 4 270 uF 8 Size 5 270 uF 10 Cable cross section of safety oriented 24 V supply voltage 0 75 1 5 mm Time between disconnection of the safety oriented 24 V supply voltage at Size 0 20 MOVITRAC B until the disconnection of Size 1 Size 5 100 the pulse pattern at output stage tswitch off ms
15. setpoints Observe the following procedure for stop category 1 Decelerate the drive using an appropriate brake ramp specified by the setpoint Disconnect the safety oriented 24 V voltage supply Safe Disconnection Manual Conditions MOVITRAC B 10 Safety Requirements Approved devices 3 2 Approved devices The following frequency inverters are permitted for applications with safe disconnection according to stop category 0 or 1 of EN 60204 1 fail safe protection against restart according to EN 1037 and compliance with safety category 3 according to EN 954 1 or performance level d according to EN ISO 13489 1 3 2 1 MOVITRAC B for AC 3 x 380 500 V supply voltage Power kW Size Type 0 55 05 MC07B0005 5A3 4 S0 0 75 05 MC07B0008 5A3 4 S0 1 1 05 MCO07B0011 5A3 4 S0 1 5 0S MCO07B0015 5A3 4 S0 2 2 OL MC07B0022 5A3 4 SO 3 0 OL MC07B0030 5A3 4 SO 4 0 OL MC07B0040 5A3 4 SO 5 5 2S MC07B0055 5A3 4 00 7 5 2S MC07B0075 5A3 4 00 11 2 MC07B0110 5A3 4 00 15 3 MC07B0150 503 4 00 22 3 MC07B0220 503 4 00 30 3 MC07B0300 503 4 00 37 4 MC07B0370 503 4 00 45 4 MC07B0450 503 4 00 55 5 MC07B0550 503 4 00 75 5 MC07B0750 503 4 00 3 2 2 Hazard caused by drive coasting Note that if the drive does not have a mechanical brake or if the brake is defective the drive may coast to a halt Note If coasting to a halt results in application dependent hazards
16. t4 With comprehensive With uncompromising knowledge in virtually quality that reduces the every branch of cost and complexity of industry today daily operations amp SEW EURODRIVE Driving the world 7 With online information and software updates via the Internet available around the clock SEW EURODRIVE GmbH amp Co KG P O Box 3023 D 76642 Bruchsal Germany Phone 49 7251 75 0 Fax 49 7251 75 1970 sew sew eurodrive com WWW Sew eurodrive com