        Operating instructions for the low pressure calibrator (LPX)
         Contents
1.    tr  glichkeit wurden folgende Normen  herangezogen     Herewith we declare that the following  product or product range    Low pressure calibrator  LPX    meet the basic requirements for the  electromagnetic compatibility  which are  established in the directive of the  European Community  2004 108 EC      This declaration is valid for products  of this Series marked with the CE sign  and which are part of this declaration     As criteria for the electromagnetic  compatibility  the following norm is  applied        Declaration of Conformity Declaration de Conformite       Nous attestons que le produit ou  gamme de produits      Calibrateur basse pression  LPX    repondent aux exigences de base en  mati  re de compatibilit   electromag   netique pr  vues par la directive de la  Communaut   Europ  enne  2004 108   CE      La pr  sente d  claration est valable  pour les produits de cette s  rie  mar   qu  s avec le sigle CE et faisant partie  int  grante de la pr  sente d  claration     La norme appliqu  e pour   valuer la  compatibilit   electromagnetique des   dits instruments est la suivante         EN 61326 2 3 2006    Diese Erkl  rung wird verantwortlich  f  r den Hersteller        This declaration is given for the manu   facturer       La pr  sente d  claration est fournie  pour le fabricant       KELLER AG f  r Druckmesstechnik  St  Gallerstrasse 119  CH 8404 Winterthur    abgegeben durch die      in full responsibility by      par          KELLER GmbH  Schwarzwaldstra
2.   Leak mode is used to determine the pressure  change over a defined period  which can be  changed     Leak measurement  10 minutes     period  factory setting     Permanently sets the applied pressure as the new  pressure zero point     Resets the pressure zero point to the factory set   display ting     Zero point for vacuum     absolute pressure is  displayed       Continuous  The device switches off       switch off function    Select units    hPa kMPa PSI mbar kp cm   inftH20 cmH20 mmHg inHgkN          automatically after a defined period  which can  be changed   starting from the last time a button  was pressed   Switch off period  factory setting   15 minutes     mbar  bar  hPa  kPa  MPa  cmH2O0  mH2O  inH2O   ftH2O  PSI  kp cm   mmHg  inHg       SELECT button    The SELECT button positioned on the  front is used to switch the device on   to select a function and to select the  various pressure units           ENTER button    The ENTER button positioned on the  front is used to activate the selected                                              SELECT button    Min    max  display    am Hzm    Leak measurement       Set zero point permanently    oe a999086      Select units    23    CEET AE O       6  Commissioning    Switch the device on    Press the SELECT button to switch the  device on  Initially  the device shows  the pressure range calibrated in the  factory  top  and the software version   year   week      Switch the device off    Keep the SELECT button pressed  
3.   to release any pressure that  may be present  If the pressure display  does not show zero  perform a zeroing  procedure  SET ZERO   Then close the  pressure relief valve     Pressure generation    You can use the hand pump  5  to make  an approximate setting for the desired  pressure     Generating negative pressure   vacuum     Engage the vacuum pump  6  in the  connection port  10  and lower the  pressure  You can then fine tune the  pressure by screwing the fine tuning  valve  8  in or out     Release pressure    Open the relief valve  7  to reduce the  pressure to an approximate level  or to  vent the low pressure calibrator     Information about the display    If no pressure can be shown on the dis   play  it will show GFL  overflow  or UFL   underflow     If pressure outside the device   s  measuring range is applied  the  last valid pressure value that was  measured will flash on the display   overload warning      Display     hPa kMPa PSI mbar kp cm     inftH20 cmH20 mmHg inHgkN          UD    BAT LOW        MAX              ARAA       4  Description of the functions    Menu navigation    If the selected function or unit is not  activated by pressing the ENTER  button within 5 seconds  the display  will return to measuring mode without  changing a setting     Shows the peak and trough pressure values  measured thus far    Display is shown with reduced resolution     Min    max  display    w doP    Leak measurement    Zero the display    Reset    Automatic     Cont  
4. 5   95  relative humidity    Button cell battery  type CR2430     gt  2000 h in continuous operation    159 x 138 x 148 mm  IP 65    bar  mbar  hPa  kPa  MPa  PSI  kp cm   cmH20O  mH2O  inH2O  ftH2O   mmHg  inHg         including accuracy  temperature coefficients  zero point and range tolerance    19    Spare parts and accessories for KELLER pressure calibrators    suitable for  Description Article number   Artelomumber    ua   mpx   mex    Vera    z KA    Battery  type CR2430 557005 0001 a  Connecting nipple  G 1 4    508832 0004 X X  including sealing ring  9 8  Test object adapter  506810 0028  G 1 4   M G 3 8   F  Test object adapter  506810 0013  G 1 4   M G 1 2   F    Sealing ring  G 1 8    mem 0001    Sealing ring  G 1 4    508635 0002    CrNi filter 30 025 2011    u    Fine tuning valve 309030 0006    Bottle of oil  0 5   650505 0005   HLP 22 BP hydraulic oil   K 114A 309010 0075       Hand pump 309005 0004 g    Konformitatserklarung    Fur das folgenden Erzeugnis       Niederdruckkalibrator  LPX       wird hiermit best  tigt  dass  es den wesentlichen Schutzan   forderungen entspricht  die in der    Richtlinie des Rates zur Angleichung  der Rechtsvorschriften der Mitglied   staaten   ber die elektromagne   tische Vertr  glichkeit  2004 108 EG   festgelegt sind     Diese Erkl  rung gilt f  r Produkte die   ser Serie  die mit dem CE Zeichen  versehen und die Bestandteil dieser  Erkl  rung sind     Zur Beurteilung der Erzeugnisse hin   sichtlich elektromagnetischer Ver
5. Operating instructions for  the low pressure calibrator  LPX        Table of contents    View 13  Notes on the operating instructions 14  1  Description of the device 14  2  General safety warnings 15  3  Operating the LPX calibrator 15  4  Description of the functions 15  5  Menu navigation for calibrators 16  6  Commissioning 16  7  Maintenance   disposal 17  8  Software for calibrators 18  Technical data 19  Spare parts and accessories for KELLER pressure calibrators 20    Declaration of conformity 31                 I  RR          lt  gt        Xxx                          ER          FIELEN  ER  EL                   A  KX             1 Port for interface cable  K 104A or K 114A    PC connection   RS485     Device base   Display   SELECT and ENTER buttons  Hand pump   Vacuum pump   Pressure relief valve    Fine tuning valve    oO ON 9 Om P Go PD    Pressure connection for test object   Serto coupler   connection nipple  G 1 4           O    Connection for hand and vacuum pumps   up to  850 mbar     13    Notes on the operating instructions     The operating instructions are in   tended for specialist workers and  trained personnel      Before each stage of work  read the  relevant notes and warnings care   fully  and keep to the sequence as  stated      Pay particular attention to the sec   tion on  General safety warnings        If you have any problems or questions   please contact your supplier or  consult KELLER directly     1  Description of the device    General des
6. cause leaks    If the filter is dirty and pressure can no  longer be transmitted  replace it with  the spare filter that is included in the  scope of delivery     CrNi Filter             17    Disposal    This product must not be disposed of   as normal household waste at the end   of its useful lifetime  To prevent pos    sible damage to the environment or   to health due to uncontrolled waste  disposal  this product  must be separated  from other waste and  recycled correctly in  order to ensure sus   tainable use of the raw  materials     8  Software for calibrators    The USB interface converter  K 114A   enables communication between the  calibrator and a computer  Before  you connect the interface converter  to the computer  install driver K 104    K 114  the software CD is included  in the scope of delivery  K 114A  or  can be downloaded free of charge at  www keller druck com     Settings on the low pressure  calibrator with the ManoConfig  software    Device settings such as the leak  measurement time or the switch off  time for the low pressure calibrator  can be adjusted using the  ManoCon   fig  software     Record measurements with the  CCS30 software    The CCS30 software records the data  measured by the pressure calibra   tor  and shows them in both graphic  and tabular form  Measured data  can be saved or exported for further  processing  You will find more in   formation about the software in the  CCS30 manual     Step by step software installation    Instal
7. cription    By means of the pressure pumps  supplied with the product  the low   pressure calibrator enables the ge   neration of pressures of  0 85 bar  relative  with the vacuum pump  to   10 bar relative  with the hand pump    The measurement technology incor   porated into this device allows ac   curate measurement and documen   tation of the characteristic of a test  object that is connected to it  The  measured pressure progression can  be displayed  evaluated and saved  with a computer monitoring program   CCS30     The calibrator is operated    with  the two function buttons SELECT  and ENTER  located directly  below the display  The calibrator it   self is powered by a 3 0 V battery  but  power can also be supplied externally  via the K 114A interface converter   Test objects  transmitters or pressure  switches  must be supplied from an  external source     Pressure range for the display    The low pressure calibrator has a  factory set pressure zero point of  O bar absolute  vacuum   The Zero  function allows any desired pressure  value to be set as the new zero point  reference    To take relative  the low pressure calibrator is  zeroed at ambient pressure  SET  ZERO   To reset the pressure zero  point to absolute pressure  use the  RES ZERO function  reset zero      measurements     14    Commissioning    A pressure resistant connection for  the test object is required in order to  use the low pressure calibrator  The  pressure connection for the test object  is a
8. down until the display shows GFF     16    Resetting peak  and trough pressure                   hPa kMPa PSI mbar kp cm     inftH20 cmH20 mmHg inHgkN                         bar                Pressure unit    Dach     Current measured value    DI  pp            Pressure change within  leak runtime    Aso          T Leak runtime in mm ss        Reset zero point to factory setting    Activate   deactivate switch off function    Press the ENTER button to execute  the shutdown         The settings made previously are  retained when you switch the device  on and off     Display mode    Display mode is the calibrator   s basic  mode  The upper part of the display  shows the pressure unit and the pres   sure that is currently measured  The  lower part of the display shows the last       function that was used  either the Min    max  display or the Leak function     Using the functions    Written descriptions of the individual  functions are given below  in addition  to the diagram above      Selecting functions    The individual sub functions are called  up from the MANO menu  Keep the  SELECT button pressed until MANG is    shown  and press ENTER to activate   You can now use SELECT to choose  the function you want  and ENTER to  execute the function  Depending on  the current setting  the first function  to be shown is either MIN MAX DISP or  LEAR DISP     Leak measurement function    Leak mode is used to determine the  pressure change over a defined pe   riod  which can be adju
9. eded    Before installing the low pressure cali   brator  check that it is suitable for your  applications                  Scope of delivery  Low pressure calibrator                2  General safety warnings    The current national regulations on  accident prevention and workplace  safety must be followed whenever  work is carried out  Internal regula   tions issued by the operator must be  followed  even if they are not men   tioned in these instructions     Never use the low pressure calibra   tor together with an external pressure  source     Do not remove any connected compo   nents  e g  test objects  when the low  pressure calibrator is under pressure   Open the pressure relief valve before  removing one of the parts     Only use the adapters and seals that  are available as accessories     Do not store the calibrator under pres   sure  only store the low pressure cali   brator with the pressure relief valve  open     Avoid the action of force of any kind  on the low pressure calibrator and its  operating controls     Do not use low pressure calibrators if  they are damaged or faulty     3  Operating the LPX calibrator    Operating the pressure calibrator is de   scribed starting on page 16     Connect the test object    You can connect your test object to the  low pressure calibrator via the pressure  connection  9      Zeroing the device    Engage the hand pump  5  in the con   nection port  10   Open the pressure  relief valve  until the red mark is visible  at most
10. l from the CD or from  www keller druck com     1   K 104   K 114 driver    2    CCS30  Control Center Series 30  3   ManoConfig  if desired     18             Jl ManoConfiguration    Configuration    COM For    COM1  COMe2  COM   COM4  COMS  COME  COM   COME  coms  COMO  COM11  COM12  COM13  COM14                     20 0 0 ee eee ee ee toe     LEX  Leak     done       Fresca San     en ll    Pater   Seed ut MEN   p       HELLER Oratimemitechnds    e e e         Ss    General   Unis   Dez scht Leak settings      iard Megs ah         Yersion 3 9 2011 05 17              Control Center  CCS30    ll x      re  RELLER       Device   nformal    Device  106    State  1   Firmware mas   SM L 20    Penge 7 01  30bar                Tob  aaa   we   j       arine         ManoConfig    Technical data    Pressure range    Overpressure    Accuracy  error band      10   40   C   Accuracy  error band      0   50   C   Leak rate   Display resolution   Number of digits on display  Measurement interval    Interface    Compensated temperature range  Operating temperature  Storage temperature    Air humidity    Power supply    Battery lifetime     Dimensions  L x W x H     Degree of protection    Selectable pressure units     0 85   10 bar  others on request   12 bar     lt  0 05  FS    lt  0 1  FS   10 bar   50 mbar   10 min    1 mbar   5 digits   0 5 seconds   RS485  the Fischer cable socket on the side fits the K 104A   K 114A    interface converter    0   50   C   0   50   C    10   60   C   
11. lready screwed to the pressure dis   tributor of the low pressure calibrator  so that it is pressure resistant when it  leaves the factory  and it must not be  dismantled    Recommended torque for the test ob   ject pressure connection  10 Nm    IMPORTANT    Nothing must adhere to the surface of  the test object  no oil  grease  water   etc   Impurities could pass through the  adapter to reach the low pressure cali   brator and damage it     Overpressure    If the pressure exceeds the measuring  range by more than 20   the measur   ing cell or the mechanism of the low  pressure calibrator may be destroyed     Recalibration    The recalibration cycle depends on  the conditions of use  Recommended  recalibration cycle  1 year        Scope of delivery      1 calibrator     1 hand pump     1 carrying case     1 vacuum pump     1 hose nipple     1 connection nipple  G 1 4        2 sealing rings   G 1 8      G 1 4         1 CrNi filter     1 spare battery  type CR2430   3 0 V      1 set of operating instructions     1 test record  5 points      USB interface converter  K 114A     1 KELLER software CD    Intended use    The low pressure calibrator  LPX  may  only be used to generate positive or  negative pressure with air  Use of the  calibrator with other media  especially  hydraulic oil  will damage it  The op   erational safety of the device supplied  is guaranteed only if it is used as in   tended  The limit values as stated  see  page 19   Technical data     must never  be exce
12. only be changed with the  Mano Con   fig    software         Software for calibrators     MANO   Continuous  function    Automatic switch off function  the de   vice switches off automatically 15 min   utes after a button was last pressed    Leak measurements are canceled by  the automatic switch off function if the  measurement time is more than the  switch off time     CONT GN  Disables the automatic  switch off function    TEE     CONT GFF  Enables the automatic    switch off function    If the  Continuous  function is en   abled  LONT flashes on the display     Leak    ok oP              Unit of pressure    bar  Dn M1 Current  19 5 ui measured value                Leak run   timein  gt  man cn  mm ss 13 06 Li  So     Pressure change  within leak  runtime    Cont    on       Cont    ott             7  Maintenance   disposal    Battery    The pressure calibrator is powered by a  3 V button cell battery  behind the  display   If the battery is low  the bat   tery symbol on the displayGBATLow   lights up     Replacing the battery    Please switch the device off  Turn the  display section ring beyond the limit  stop until it is released from the hous   ing section  turn through about 180      Open the battery compartment and  change the battery  type CR 2430      Pressure coupling filter    The low pressure calibrator has a CrNi  filter  11 x 8  material DIN 1 4404    fitted behind the pressure coupling  in order to prevent impurities from  penetrating inside it  which could  
13. sse 17  D 79798 Jestetten         Jestetten  4  Oktober   October   Octobre 2012    af  ff C      Fa  fi  d d d d Gd  K ft    ur Le    Hannes W  Keller    Gesch  ftsf  hrender Inhaber   Managing Owner   Pr  sident Directeur G  n  ral  mit rechtsg  ltiger Unterschrift   with legally effective signature   d  ment autoris   a signer       KELLER AG f  r Druckmesstechnik  St  Gallerstrasse 119     CH 8404 Winterthur  Tel   41  0 52 235 25 25    Fax  41  0 52 235 25 00    www keller druck com    November  November  Novembre 2012    
14. sted  The unit  to be tested must be connected to the  low pressure calibrator on the pressure  side     Start leak measurement    Activate the MANG menu  The display  shows LEAK DISP  Press the ENTER  button and then the SELECT button   Press ENTER to confirm LEAK START   The leak measurement starts  and the  display alternates between the current  leak time and the pressure change  measured thus far     Active leak measurement    During leak measurement  the lower  part of the display alternates each  second between the measurement  time that has now elapsed  mm ss   and the pressure change measured  thus far                    Se Mano mode  ENTER       Leak    d ICP     gt  Launch Leak   mode by press   ing the ENTER  button          ENTER          Start the leak  ErE measurement  with ENTER          ENTER           Unit of pressure    bar  no d n     Current                Leak run  measured value  timein        Ti 8  men 1 fa 0b at   l Pressure change  within leak  runtime       End leak measurement early    To end an active leak measurement  early  press the ENTER button and    confirm the  LEAK STOP    display by  pressing ENTER     Leak measurement completed    If the leak measurement time has  elapsed or if the measurement was  manually ended ahead of time   the display alternates between the  elapsed leak measurement time and  the measured pressure change     Set leak measurement time    The leak measurement time is preset  to 10 minutes in the factory  and it can  
    