Home

NX-595E Installation Manual

image

Contents

1. RTC Real Time Clock is an onboard component that holds the current time date setting A built in power sense circuit detects power failures and automatically switches to the backup supply This significantly reduces the chance of a loss of date time in periods of extended power outage Phone Line connection and network connection All of the above features plus Email Reporting Up to three email addresses can be entered DHCP or Dynamic Host Configuration Protocol is a computer network protocol used by devices to obtain configuration information for operation in an Internet Protocol network This protocol reduces system administration workload allowing networks to add devices with little or no manual intervention NX 595E Web Interface Once connected to the network users will enjoy the simple web user interface that is supplied with the NX 595E Enter the IP address of your NX 595E into a web browser to access the NX 595E Configuration Server Here the user can configure pin codes arm and disarm partitions view the last 185 event history enter and change all voice and divert phone numbers and assign email address Installers have further access to network settings feature lists and outputs Relays The two onboard relays are fully configurable and come defaulted for door release one and door release two Phone Line connection network connection and integrated into the door intercom system All of the
2. Z2 Panel Bus NX 181xx Audio Lines Entrance camera 1 Entrance camera 2 Additional Zones Description Network J10 Wai G Iin J1 LE OE E 6 Audio 1 Tap Positive terminal on the NetworX panel Common terminal on the NetworX panel Data terminal on the NetworX panel Audio Line A positive Audio Line A negative Audio Line B positive Audio Line B negative Common terminal on outdoor station 1 Audio terminal on outdoor station 1 Positive terminal on outdoor station 1 Common terminal on outdoor station 2 Audio terminal on outdoor station 2 Positive terminal on outdoor station 2 1 3 Zone Common return for Zone loop a Ah Zone Green White Green Orange White Orange Yellow Red Blue Yellow Red Blue 3K3 Single EOLs 3K7 Low zones 6K9 High zones NX 595E Installation Manual 17 18 19 20 21 22 23 24 25 AO Com A1 NC 1 C1 NO1 NC2 C2 NO2 Future Use ER1 Entry Relay 1 ER2 Entry Relay 2 Normally closed Common Normally open Normally closed Common Normally open Wiring Structure Figure 8 NX 595E Installation Manual 0000000000000000000000000 na Pos Com Data Vie Yi V2 V2 EiC E1A Ei E2C E24 E2 Z1 Com 2 AD Com Al NC1 C1 NO1 NCZCZNOZ TT Note In this example ER1 relay is set to dry contacts via J11 Zones 4 C 7 i EN p a I i i Ek gt l
3. Opening the enclosure may cause a tamper alarm to sound 7 Click Sites button to save the details 8 Click the name of the Site the app will now connect you to NX 595E T By eo uF aE 11 52 AM Pa DN su NX 595E j A Sites Site Name NX 595E gt DONE NX 595E Installation Manual 35 Access via iPhone App The built in web server can also be accessed from an Apple iPhone via a dedicated app This app is available to download from the Apple App Store Carrier charges may apply and an iTunes account is reguired Most features available from the web server are displayed inside the iPhone app 1 On your iPhone go to the Apple App Store Available on the J App Store Search for xConnect Install the app Click the icon on your device to launch it Click to add a new account D pN Enter the details of your security system this should be on the back of this manual if not please contact your security installation company or builder for assistance The serial number is also printed on the back of the NX 595E unit inside the NetworX enclosure Opening the enclosure may cause a tamper alarm to sound 7 Click Sites button to save the details 8 Click the name of the Site the app will now connect you to NX 595E 12 11 AM Site Info Site Name Enter a name NX 595E Description Enter a description Serial Number Enter your serial Passcode 1sessess Us
4. Entrance Camera 2 x n Refer to intercom installation manual for correct cable selection Future Use This relay is controlled from the NX 181xx communicating with outdoor station 1 This relay is controlled from the NX 181xx communicating with outdoor station 2 ERI ER2 L HLS SM J1 Tap Camera 2 a di J Entrance Camera 1 Note Video Intercom Monitor reguires independent power source FAG Freguently Asked Guestions 1 If I am upgrading from a previous version of NX 595E what do I need to do The new NX 595E will automatically configure itself in the cloud and provide email and remote access services without further configuration Older versions of NX 595E reguired port forwarding to allow remote access The new version does not reguire port forwarding so please remove any port forwarding settings from your router as these may interfere with the new cloud service Do I need port forwarding No the new NX 595E does not reguire port forwarding Built in cloud services automatically configure remote connections so it is easier to get online Do I need an email server You do not need an email account to send emails as the new NX 595E will send emails using a secure cloud service This is automatically configured and you only need to specify the destination email address es You can optionally provide your own email account and SMTP server settings a
5. iPhone app and remote web access WRITE THIS CODE ON THE BACK OF THE USER MANUAL The default passcode is 00000000 and it disables remote access Add a Username to your NX NetworX System In this example we ve entered User1 WRITE THIS USERNAME amp PIN CODE ON THE BACK OF THE USER MANUAL Configure Users Lajout ECL of USE Useri Armbar Displann lise 3 Higar FAM 1244 p s c n m Usera cma Reporting User Aut ty hS Reporting Clam Le HEDDI o ch CMa Dreri fe Ar fF Eryn ure 5 le Report CO Reserved wbwnurk Set r Cud tps User Areas Fel Aren 1 Flarn E Fepam Flapa rl Arg FF NX 595E Installation Manual Access via Android App The built in web server can also be accessed from an Android device via a dedicated app This app is available to download from the Google Play store Carrier charges may apply and a Google account is reguired Most features available from the web server are displayed inside the Android app 1 On your Android device go to the Google Play store SET IT ON Google play Search for xConnect Install the app Click the icon on your device to launch it Click to add a new account D on a o DN Enter the details of your security system this should be on the back of this manual if not please contact your security installation company or builder for assistance The serial number is also printed on the back of the NX 595E unit inside the NetworX enclosure
6. in Location 24 are used to set the networks DNS server address Location 25 UHS Client Server IP address The 4 segments in Location 21 are used to set the IP address of the NX 595E so it can be identified on the network by the UHS ultra agent Currently not supported Location 26 UHS Client reporting selections Event selection for UHS client reporting Segment 1 Alarm Restores 3 Open Close alarm system disarmed Open alarm system armed close Zone Bypass and restores Zone Trouble and restores Power Trouble and restores AC Failure or Low Battery 7 Tamper and restores Zones Box Keypad and Zone Activity Monitor Test Reports Segment 2 System Trouble and restores Siren Phone Expander Short Circuit 2 Failure to Communicate 4A NX 595E Installation Manual Sensor Lost or Sensor Low Battery a Program mode Download and Log Full full log must be enabled in system options Cancel Code cancel reporting must be enabled in partition options 6 Recent Closing Exit Error A Reserved NX 595E Installation Manual 45 System Status Messages Zone Number Zone Name In alarm This zone has triggered a system alarm condition Is bypassed This zone is isolated disabled and will not activate an alarm Chime is set This zone is part of the chime group Is not secure This zone is not closed Fire alarm This zone has triggered a fire alarm Tamper This zon
7. mode by using a keypad and enter device 191 By default this is an extra layer of security to prevent unauthorised remote access Then try again from a web browser You can also enable web access permanently on the NX 595E in Location 19 Segment 1 Option 6 On While the NX 595E is in program mode On a windows computer click Run type cmd press Enter then ping ip address lf there is an error it will show timed out and you should check your network If you see a time then your computer can talk to the NX 595E You can also enable ping permanently on the NX 595E in Location 19 Segment 1 Option 4 On 2 I m not receiving any emails a o o o Perform testing using a standard user PIN the installer account by default does not send all reports Check that the emails are not being captured in your SPAM folder or blocked by a firewall Check the email address is correct Check that the event is ticked in the NX 595E settings Check that you are receiving other emails Check that the relevant reporting options are enabled in the panel programming Try using xConnect app to verify your system is connecting to the servers Loading Factory Defaults device 191 The NX 595E is automatically set to device number 191 and programming is carried out like all other NetworX modules The following examples show how to access the programming of the NX 595E via a standard keypad or a NX 181xx Voice keypad The NX 595E will requ
8. networks to add devices with little or no manual intervention Require SSL SSL or Secure Sockets Layer is a security protocol for communication over networks such as the Internet and reduce the chance of someone eavesdropping on your interaction with the security system If Require SSL is selected then port 80 standard http will be disabled and you must use https which by default is port 443 If Require SSL is not enabled then you can connect using either http on port 80 or https on port 443 Enable Web page updates without a login When enabled allows updating of the NX 595E Configuration Server s web pages via FTP Normally disabled 42 NX 595E Installation Manual Enable Ping in the run mode The ping command is always functional whilst the NX 595E is in program mode and is defaulted to NOT operate whilst the NX 595E is in the normal run mode Enable this option to allow the NX 595E to respond to ping commands in normal operation For security reasons it is recommended this option remain disabled during normal operation Enable periodic update of clock via internet The NX 595E will check its internal and use the internet to compare it against GMT time This is done every 15min and will update itself if the variance is greater than 3 minutes Enable web programming When enabled a user can access Network settings location list Outputs and IP reporting via the NX 595E s web pages Otherwise the NX 595E will need to be
9. 1 Connects to device 191 NX 595E 4 9 1 0 Defaults the device Note only required once You are now ready to begin NX 595E programming 5 Exit Moves back to step 3 6 Exit Exits programming 18 NX 595E Installation Manual Enrolling the NX 595E NetworX control panels can automatically find and store all modules that are connected to the communications bus such as NX 595E keypads zone expanders wireless receivers output boards and other modules This allows for polled supervision of these modules and if the NetworX panel does not detect an enrolled module a service condition will be generated The NX 595E module will be automatically enrolled if you perform the defaulting procedure described above Enrolling takes about 12 seconds and user codes will not be accepted during this time Accessing the NX 595E via a Touch Tone Phone This section describes how to access the NX 595E via an off site touch tone phone The NX 595E must be on an independent line to the touch tone phone from which you are trying to connect The NX 595E must be pre programmed by your security service provider to automatically answer the incoming call once the predetermined number of calls rings have been reached When the desired number of calls rings has been reached the NX 595E will grab the phone line and announce the following Enter your code for system access press star to cancel Enter your user master code Instal
10. 95E will check its internal and use the internet to compare it against GMT time This is done every 15min and will update itself if the variance is greater than 3 minutes NetworX Protocols This protocol is disabled by default but is active for the first 5min after power up Allows devices such as iPhones and UHS devices to communicate with the NX 595E via NetworX protocols xConnect This enables the app and automatic email configuration Can only be disabled from a keypad IP Address An Internet Protocol IP address is a numerical label that is assigned to devices participating in a computer network If DHCP is enabled and supported by your network the NX 595E IP address will be automatically assigned otherwise you will be required to enter your unique IP address here Subnet Mask Allows a network to be divided into subnets and allows the flow of network traffic between hosts to be segregated based on a network configuration Applying the subnet mask to an IP address splits the address into two parts an extended network address and a host address A typical subnet mask is 255 255 255 0 Primary DNS IP address of the primary DNS server DNS Domain Name system allows dedicated servers on the internet to be assign both an IP address and a corresponding name called a domain name Secondary DNS IP address of the secondary DNS server DNS Domain Name system allows dedicated servers on the internet to be assign both an IP address
11. Control address MAC address is a unique identifier assigned to most network interface cards by the manufacturer for identification Host Name Fixed as NX 595E Enable DHCP DHCP or Dynamic Host Configuration Protocol is a computer network protocol used by devices to obtain configuration information for operation in an Internet Protocol network This protocol reduces system administration workload allowing networks to add devices with little or no manual intervention Reguire SSL SSL or Secure Sockets Layer is a security protocol for communication over networks such as the Internet and reduce the chance of someone eavesdropping on your interaction with the security system lf Reguire SSL is selected then port 80 standard http will be disabled and you must use https which by default is port 443 If Require SSL is not enabled then you can connect using either http on port 80 or https at the configured SSL port NX 595E Installation Manual 27 Web Updates When enabled allows updating of the NX 595E Configuration Server s web pages via FTP Normally disabled Ping The ping command is always functional whilst the NX 595E is in program mode and is defaulted to NOT operate whilst the NX 595E is in the normal run mode Enable this option to allow the NX 595E to respond to ping commands in normal operation For security reasons it is recommended this option remain disabled during normal operation Web Time Updates The NX 5
12. abled in system options 6 Cancel Code cancel reporting must be enabled in partition options e Recent Closing Exit Error mo Rew NX 595E Installation Manual 39 Location 5 Alarm Phone Number One 1 The first voice message phone number is programmed in Location 5 15 Pulse dialing in the segment where pulse dialing should begin 14 Indicates the end of the phone number 13 Creates a four second delay 12 11 Segments 1 20 14 14 14 14 14 14 14 14 14 14 11414 14 14 14 14 14 14 14 14 Location 6 Alarm Phone Number Two 2 The second voice message phone number is programmed in Location 5 15 Pulse dialing in the segment where pulse dialing should begin 14 Indicates the end of the phone number 13 Creates a four second delay 12 11 soera Location 7 Alarm Phone Number Three 3 The third voice message phone number is programmed in Location 5 15 Pulse dialing in the segment where pulse dialing should begin 14 Indicates the end of the phone number 13 Creates a four second delay 12 11 Segments 1 20 14 14 14 na na 14 ra ra 14 Ja fna na r4 ra ra ia 4 ra fra Note If multiple phone numbers are entered the NX 595E will call each number in turn until it is answered or the designated number of dial attempts set in Location 3 has been reached The NX 595E will first call phone number 1 wait 25 seconds for a PIN to be ent
13. above features plus Call divert This feature will call up to three different phone numbers when a visitor presses the call button on the outside door station whilst the Networx security system is armed Once the call is connected a bi directional conversation can take place and the called party has the ability to operate the onboard relay allowing access to the premises Remote listen in two way communication this feature allows users to connect to the outdoor station from a remote location Phone Line connection network connection integrated into the door intercom system with NX 181xx Voice keypads NX 595E Installation Manual All of the above features plus NX 181xx Voice keypads can be configured to answer a call initiated from either of the two door stations they can also control the NX 595E modules onboard door release relays Remote listen in two way communication this feature allows users to connect to any or all of the connected NX 191xx Voice keypads from a remote location an listen in to any audio within that room rooms NX 595E Installation Manual Installing The NX 595E into the enclosure Inside the NetworX enclosure several 2 holed insertion points have been constructed This allows for either vertical or horizontal placement of the modules Notice that the insertion points have two sizes of holes a larger hole and a smaller hole Figure 1 The black plastic PCB guides are grooved on one
14. and a corresponding name called a domain name SSL Port Selectable port configuration a default port is 443 Web Access Passcode This code allows the iPhone app to connect to this NX 595E it does not affect the operation of other features xConnect Server 1 This server address should not be changed it enables the remote web access iPhone app and email services without having to set up port forwarding xConnect Server 2 This server address should not be changed 28 NX 595E Installation Manual Feature List Feature Setup Logout Ll Enable Zone Doubling Arm Disarm O Enable Ans Machine Defeat Rings to Answer i n Sensors Start Zone n History E installer Name installer Users CEA service Number Email Reporting GMT Offset 0 GMT vid v SMS Reporting Daylight Saving Time Start Disabled First Sunday Yoice Reportin P Hd Daylight Saving Time End Call Divert Disabled First Sunday Save Config Sanss Isis Device ID 1 Network settings Firmwa re 5 T a Outputs Hardware 10 IP Reporting Bootload 40 web We rsio n CN 0 1 0 6 a Voice a5 Lanquage 0 Zone doubling this feature will allow the two onboard zones to double to four zones zone Lower Zone Higher Zone Single EOL 3K3 N A N A Zone Doubled EOL s N A 3K7 6K9 Answering machine defeat When answering machine defeat is enabled accessing the NX 595E remotely is accompl
15. ce Reporting will call up to three phone numbers and announce alerts in plain English e Email Reporting will email up to three addresses no mail server needs to be configured Authorized users may customize voice recordings for user names zone names partition names room names output names and system names These recordings offer a level of system customization usually reserved for more elaborate installations The NX 595E can also store and forward to NX 181xx Voice keypads exit and entry messages These messages can be left for other users of the security system NX 595E modules built in web server allows users to arm disarm individual partitions check system status enable disable user codes modify email accounts and Voice phone numbers from any standard web browser Advanced intercom features are also incorporated within the NX 595E Imagine a visitor to your home pressing the button at your front door intercom and then being able to talk to you on your mobile phone anywhere in the world Maybe it s a courier delivering a parcel You may wish to open the garage door and allow them to drop the parcel inside NX 595E Installation Manual 7 Features amp Benefits The more integration that is performed the more features and benefits will become available Feature Connection Phone Line Network Intercom NX 181xx Dial Up Control Yes R Dial Up Programming Yes Voice Reporting Yes A 4x Extra Zones Y
16. e event must occur in before the output will activate Schedule Times Sets the Opening Closing hours and minutes 24 hour format and the days of the week the event must occur in before the output will activate 32 NX 595E Installation Manual IP Reporting Logout Arm Disarm Sensors History Users Email Reporting SMS Reporting Voice Reporting Call Divert Feature Setup Network Settings Outputs IP Reporting NX 595E Installation Manual IP Reporting Save Config Serial Number Receiver IP Addr UDP Base Port Tunnel Part Reporting Selectors Alarms Restores M Opening Closing M Bypass lv Zone Trouble M Power Trouble Tampers Test Reports System Trouble M Fail To Communicate Sensor Trouble Start End Program Mode Cancel Recent Close Reserved Reserved Save Config 33 Enable Remote Web Access To enable remote web page and iPhone app access for your customer 34 Network Settings Look for the serial number label on the back of the NX 595E PCB WRITE THIS SERIAL NUMBER ON THE BACK OF THE USER MANUAL Find the IP address of your NX 595E This is stored in Device 191 Location 21 Enter the IP address into a web browser then login Username installer Password 9713 Make sure your computer is on the same network as the NX 595E Go to Menu gt Network Settings and change the Web Access PIN This 8 digit passcode grants access to the
17. e has triggered a tamper alarm Trouble fault This zone has an open circuit Loss of wireless supervision This zone is a wireless device and has lost its communication link with the control panel Low battery This zone is a wireless device and needs its battery changed Partition Number Partition Name Is on in the away mode This partition is armed in the away mode Is on in the stay mode This partition is armed in the stay mode Is ready This partition is secure and ready to be armed Is not ready This partition is NOT ready to be armed a zone is not secure All partitions are on in the away mode All partitions in this multi partition system are armed in the away mode All partitions are on in the stay mode All partitions in this multi partition system are armed in the stay mode All partitions are ready All partitions in this multi partition system are secure and ready to be armed System AC power fail The security system has lost its electricity power Low battery The security systems back up battery requires charging Battery test fail The security systems back up battery requires changing Box tamper The security systems cabinet tamper input has activated Siren trouble The security systems external siren has a problem Over current The security system is drawing too much current Time and date loss The security system time and date need resetting Communication fault The
18. edge where the PC Board will be seated The end with the half moon protrusion fits into the larger hole The smaller hole is for the screw Figure 2 Place the first black plastic PCB guide in the top insertion point grooved edge downward The half moon protrusion will be in the large hole It does not require force Insert one of the provided screws into the smaller hole from inside the can to secure it in place A screwdriver should reach through the notch that runs the length of the guide to tighten the screw The second PCB guide should be positioned opposite of the first grooved edge up and placed in the lower insertion point using the same procedures described above Once mounted screw it in securely Figure 3 The PC board should slide freely in the grooves of both guides Figure 1 Figure 2 Figure 3 NX 595E Installation Manual 11 Wiring The NX 595E Remove all power to the NetworX security system and connect NX 595E s terminals POS COM amp DATA to the NetworX bus A 5 wire interconnecting cable is supplied with the NX 595E Connect one end to J1 Audio Tap on the NX 595E and the other end to J4 Audio Tap on the NetworX board Important Ensure the trace is aligned with pin 1 on both taps Refer to Figure 4 5 6 amp 7 for correct orientation 1 Connect J14 RJ45 to available network port via a patch cable 2 Connect E1C E1A E1 in parallel to front door camera 1 3 Connect E2C E2A E2 in parallel to
19. er Name PIN Troubleshooting e NX 595E may not work on corporate network due to firewalls proxy servers and other security settings Connect it to a network port that can provide direct access to the internet 36 NX 595E Installation Manual e Check that other devices on the same network can connect to the internet if they are working then confirm all access codes are correct serial number Web Access Passcode username PIN NX 595E Installation Manual 37 Worksheets Location 0 Audio level adjustment for Outdoor Stations The 2 segments in Location 0 are used to set the volume level to and from an outdoor station Segment 1 controls the intercom volume level from the audio bus to an outdoor station Segment 2 controls the intercom volume level from an outdoor station to the audio bus Options are from 1 15 Note It may be necessary to adjust the NX 181xx microphone sensitivity found in the mute menu option 9 depending on the selected setting in segment 1 Location 1 NX 595E Features Option 1 is used to set the zone doubling feature This feature will allow the two onboard zones to double to four zones Please refer to Location 18 for starting zone number If this feature is unselected both onboard zones remain as single end of line zones and require 3K3 resistors When Zone doubling is enabled Lower zones 3K7 Higher zones 6K9 Option 2 Answering machines usually answer calls afte
20. ered if not entered it will hang up for 6 seconds then call phone number 2 and repeats this process for phone number 3 Location 8 Reserved Location 9 Reserved Location 10 Reserved Location 11 Reserved Location 12 Reserved 40 NX 595E Installation Manual Location 13 Reserved Location 14 Reserved Location 15 Divert Phone Number One 1 The first Divert phone number is programmed in Location 15 Call divert phone numbers will be dialed in seguence when a call is initiated from an outdoor station The outdoor station must be interfaced with the NetworX security system via the NX 595E The NetworX security system must also be in the armed condition 15 Pulse dialing in the segment where pulse dialing should begin 14 Indicates the end of the phone number 13 Creates a four second delay 12 11 sarees yao w w w w w w w w w w a a w a a a a a a a Location 16 Divert Phone Number Two 2 The second Divert phone number is programmed in Location 16 Call divert phone number 2 will be dialed if call divert phone number 1 is busy when a call is initiated from an outdoor station The outdoor station must be interfaced with the NetworX security system via the NX 595E The NetworX security system must also be in the armed condition 15 Pulse dialing in the segment where pulse dialing should begin 14 Indicates the end of the phone number 13 Creates a four second delay 12 i sare
21. es Real Time Clock Yes a i 2x Extra Relays Yes Email Reporting Yes Automatic DHCP Yes Built In Web Server Yes iPhone app Yes No mail server and port Yes forwarding set up required Call Divert Yes Remote Listen In to Outdoor Station Yes NX 181xx Access to Intercom and Door Release Yes Remote Listen In to NX 181xxs Yes Phone Line connection Voice Reporting The NX 595E can phone the user and announce selected event conditions in a human voice This is in addition to alarm signals sent via the NetworX panel to the central monitoring center Users can customize individual name recordings for zones partitions users rooms and outputs No more confusing beeps or sirens Dial up control The NX 595E can be access by any outside touch tone telephone and once connected the inbuilt Personal Voice Guide PVG will navigate you through all available menu options From basic Arming Disarming control to more advanced menus like zone bypassing and System recordings Dial up programming An invaluable feature for the installer is the ability to remotely access the NX 595E from any outside touch tone telephone to carry out full system interrogation or advanced programming NX 595E Installation Manual Zones There are two onboard zones that can be zone doubled to for use within the security system Only available on the NX 8E control panels
22. front door camera 2 4 Connect V1 V1 and V2 V2 audio input in parallel with NX 181xx audio lines A and B 5 Connect Zones as required e 3 3K Single EOL s e 3 K Lower zone EOL s when zone doubled e 6 9K Higher zone EOL s when zone doubled 6 Select relay contact requirements via jumpers J10 and J11 Place link between GND and C for negative switch and 12 V and C for positive switch remove link for dry contact switching When integrating the NX 595E with an external camera and video monitor it is important to power up the monitor before you power up the NX 595E The NX 595E will then identify the presence of the monitor and switch off its 5 VDC supplied to E1A and E2A and utilize the power supplied from the video monitor NetworX NX Audio tap connections Figure 4 00000 NX8 00000 NX 6 Sa Terminal Strip Figure 5 Terminal Strip 12 NX 595E Installation Manual Figure 6 Terminal Strip Important Ensure the trace is aligned with pin 1 on both panel and NX 595E audio taps NX 595E Installation Manual PCB Layout Figure 7 Pos Com Data V1 Wi Vit V2 EIC EA Ei E2C E2A E2 71 Com Z2 AD Com A1 ICP J12 Ra O J11 ccc DD00000000000000000000000 NC1CINO1 NC2C2 NOE Terminal descriptions Terminal J INI OO oO ATOJN 10 11 12 13 14 15 16 Pos Com Data V1 V1 V2 V2 E1C E1A E1 E2C E2A E24 Z1 Com
23. h this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info 2006 66 EC battery directive This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union See the product documentation for specific battery information The battery is marked with this symbol which may include lettering to indicate cadmium Cd lead Pb or mercury Hg For proper recycling return the battery to your supplier or to a designated collection point For more information see www recyclethis info www utcfireandsecurity com or www interlogix com www interlogix com customer support or www utcfssecurityproducts eu Content Important information 5 Limitation of liability 5 Advisory messages 5 Disclaimer 6 Warranty 6 Introduction 7 Features amp Benefits 8 Phone Line connection 8 Phone Line connection and network connection 9 Phone Line connection network connection and integrated into the door intercom system 9 Phone Line connection network connection integrated into the door intercom system with NX 181xx Voice keypads 9 Installing The NX 595E into the enclosure 11 Wiring The NX 595E 12 PCB Layout 14 Terminal descriptions 14 Wiring Structure 15 FAQ Freq
24. ht savings begins and ends for the particular installation region DST Start End week Selects which Sunday daylight savings begins and ends for the particular installation region Firmware Hardware Web version Voice and Language Displays the current versions loaded on the connected NX 595E 30 NX 595E Installation Manual Outputs Logout Arm Disarm sensors History Users Email Reporting SMS Reporting Voice Reporting Call Divert Feature Setup Network Settings Outputs IP Reporting Activation Event Activation Time 5 Activation Event Activation Time 151 Configure Outputs Save Config Output 1 Programming Unlock Door 1 i O Minutes O Latch Output 1 Options O Code Reset O Invert Output 1 Areas Area 1 M Area 2 M Area 3 M Area 4 Area 5 M Area 6 M Area 7 M Area 8 Output1 Schedule O Open Schedule O Close Schedule Output 1 Schedule Times Open Hour z Open Minute 0 Close Hour 17 Close Minute n Output 1 Schedule Days O Sun M Mon M Tue M Wed Thu M Fri O Sat Output 2 Programming Zone Burg Alarm v Minutes CJ Latch Output 2 Options O Code Reset M Invert Output 2 Areas Area 1 M Area 2 Ll Area 3 Ll Area4 Ll Area5 Ll Areas M Area Ll Areas Output 2 Schedule O Open Schedule Ll Close Schedule Output 2 Schedule Times Open Haur Open Minute 0 Close Hour 17 Close Minute 0 Output 2 Schedule Days O sun M
25. in program mode to access these additional features By default this is off to prevent an end user access to these additional menus Enable NetworX protocol server Disabled by default do not change Enable Service Enabled by default Enabling this option allows you to use the app xConnect Segment 1 tA CNAU O DEATH Y O Enable NetworX protocol server Enable Service Location 20 IP Gateway The 4 segments in Location 20 are used to set the IP address of the networks gateway Enable Web programming of Network settings location list Outputs and IP reporting without NX 595E needing to be in program mode In homes the gateway is usually the Internet Service Provider ISP device that connects the user to the internet such as a DSL or cable modem In an enterprise system the gateway is the node that routes the traffic from a workstation to another network segment The default gateway is commonly the node connecting the internal networks and the outside network Internet NX 595E Installation Manual 43 Location 21 NX 595E IP Address The 4 segments in Location 21 are used to set the IP address of the NX 595E so as it can be identified on the network Location 22 Subnet Mask The 4 segments in Location 22 are used to set the Subnet mask Location 23 DNS Server 1 The 4 segments in Location 23 are used to set the networks DNS server address Location 24 DNS Server 2 The 4 segments
26. interlogix 3 United Technologies NX 595E Installation Manual J P N 230242 REV C e ISS 02JUL14 Copyright Trademarks and patents Manufacturer Compliance EU directives yn y Contact information Customer support 2014 UTC Fire amp Security Americas Corporation Inc All rights reserved This document may not be copied in whole or in part or otherwise reproduced without prior written consent from UTC Fire amp Security Americas Corporation Inc except where specifically permitted under US and international copyright law The NX 595E name and logo are trademarks of UTC Fire amp Security Americas Corporation Inc NX 595E name is a trademark of UTC Fire amp Security Americas Corporation Inc Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Placed on the market by UTC Fire amp Security Americas Corporation Inc 3211 Progress Drive Lincolnton NC 28092 USA Authorized EU manufacturing representative UTC Fire amp Security B V Kelvinstraat 7 6003 DH Weert Netherlands CE UTC Fire amp Security hereby declares that this device is in compliance with the applicable requirements and provisions of one or more of the Directives 1999 5 EC 2014 30 EU and 2014 35 EU For more information see www utcfireandsecurity com or www interlogix com 2002 96 EC WEEE directive Products marked wit
27. ire defaulting the first time it is accessed by entering 9 1 O or 9 1 O ENTER depending on the keypad type This will only be reguired once NX 595E Installation Manual 17 Using a NX 181xx Voice keypad Step Device Programming Using NX 181xx Voice keypads Example Defaulting to factory settings 1 MENU 0 Selects main menu Option 0 Advanced system configuration 4 Enter your code touch menu to exit 2 Enter your 4 or 6 digit Programming code Touch 1 for keypad configuration Touch 2 for panel and device configuration q Touch 3 to configure service provider phone number Touch menu to exit 3 2 Selects Panel and Device configuration 4 Select a device number followed by enter Touch menu to go back 4 LYM 9 T1 Connects to device 191 NX 595E ENTER Selected device 191 is connected 4 _ Select a Location number followed by enter Touch menu to go back 9l 1 0 i 2 ENTER Defaults the device Note only required once You are now ready to begin NX 595E programming 6 MENU Moves back to step 4 select a device number 7 MENU Moves back to step 3 Advanced system configuration selection 8 MENU Exits from Advanced system configuration Using a Standard Keypad Icon or LCD Step Device Programming Using standard keypad Example Defaulting to factory settings 1 8 Selects Panel and Device programming 2 Enter your 4 or 6 digit Programming code o 1 9
28. ished by calling the phone number the NX 595E is connected to and allowing it to ring once or twice then hanging up Wait 10 seconds Then calling back the NX 595E which will now answer the next incoming call The second call must be made within 60 seconds of the first call Rings to Answer The number of rings the NX 595E must detect before answering the telephone line when initiating a communication session A value of 1 to 15 can be entered Note Generally rings to answer would be disabled when enabling answering machine defeat Starting Zone Used to enter the starting zone number of the additional zones on the NX 595E NX 595E Installation Manual 29 Data Zones Data Zones Data Zones Data Zones 9 9 12 41 41 44 73 738 76 105 105 108 17 17 20 49 49 52 81 81 84 113 113 116 20 25 28 57 27 60 89 89 02 121 121 124 33 33 36 65 65 68 97 97 100 Note Additional zones are only available on the NX 8E This feature is not available for NX 4 or NX 8 panels Installer Name Default installer name is installer and is case sensitive Installer name access will present all tabs Master user name access will not present the Network settings location list Outputs or IP reporting tabs Service Number The system service number will be announced at NX 181xx Voice keypads when a system fault is present GMT Offset Hours Minutes Sets local GMT Greenwich Mean Time DST Start End month Selects the months daylig
29. ler code default master code is 1234 and default Installer code is 9713 the NX 595E will announce the recorded system name if recorded and list all accessible main menus you can now make your selection as reguired You are now connected to system name Press for system status 1 Press 2 for system control Press 3 for intercom control Press A for output control Press 5 for message bank Press 0 for system configuration Press to exit Denotes master code access only The above sequence will be shown throughout this manual as PIN Location 2 Dial attempts must be set to the desired number of rings before the NX 595E will answer an incoming call to begin a voice session Location 1 segment 2 answering machine defeat can also be used to bypass onsite answering machines lf answering machine defeat is enabled accessing the NX 595E remotely is accomplished by calling the phone number the NX 595E is connected to and allowing it to ring once or twice then hanging up waiting 10 seconds then NX 595E Installation Manual 19 calling back the NX 595E which will now answer the next incoming call The second call must be made within 60 seconds of the first call An installer code is unrestricted and can access all partitions of the NX 595E including menu 0 0 Panel and device configuration Main Menu Structure EE System Status System Control 2 1 System Status 2 2 Partition Control 2 3 Zone By
30. nd the NX 595E will use this instead to send you emails Ask your email provider for these settings How do I connect program the NX 595E a Default the NX 595E following the instructions below b Ensure your router supports DHCP most do out of the box c Connect the NX 595E to it using an Ethernet cable The router should automatically assign the NX 595E module an IP address d On a keypad connected to the NetworX security system enter 8 Master PIN O 1914 21 which will tell you the IP address of the NX 595E Press to scroll through each segment of the IP address e On a computer enter the IP address into a web browser to bring up the login page Your NX 595E must remain in program mode to allow access f Login to the NX 595E The default username password is installer 9713 g You can now program any additional settings you require via the web interface What if I cannot connect to NX 595E with my computer a Check that your router has DHCP enabled refer to your router manual for details b Default the NX 595E This will ensure DHCP is enabled c Check that an IP address has been allocated in Location 21 of the NX 595E If it is 0 0 0 0 then DHCP is not working correctly You should assign the NX 595E a static IP address in Location 21 Make sure that it is NX 595E Installation Manual on the same subnet as our computer and that the IP address is not used by another device Put the NX 595E into program
31. oduct caused by misuse careless handling or where repairs have been made by others No other guarantee written or verbal is authorized by UTC Fire amp Security Americas Corporation Inc 6 NX 595E Installation Manual Introduction The NX 595E is an optional module that may be added to your NetworX security system to provide remote access and reporting features You can also integrate the security system to devices such as intercom doors lighting and air conditioning via low level relays NX 595E provides a web interface accessible via computer or smart phone and simple configuration for remote access You can access the NX 595E using these methods e Personal Voice Guide PVG When accessing the NX 595E via a touch tone phone the inbuilt PVG will talk to you and guide you through operating your security system You can dial in and check the status of your security system change a user s PIN number enter a new alarm phone number or arm your system with easy to follow voice prompts e Built In Web Server provides access from PC Mac or smart phone with web browser It allows users to arm disarm individual partitions check system status enable disable user codes modify email accounts and Voice phone numbers from any standard web browser e iPhone app provides access from an easy to use iPhone app without needing to set up port forwarding The NX 595E can interact with you with one or more of these e Voi
32. on Tue M Wed Thu M Fri O Sat The two onboard relays are defaulted as Door 1 and Door 2 control and are controlled when an intercom session is established between an outdoor station and NX 181xx Voice keypads Relay trigger events are selectable and can be chosen from a drop down Activation events list from within the web interface Events can only be selected from within the NX 595E web interface Note From the activation event drop down list Output 1 Trigger and Output 2 Trigger are fixed X10 module commands O and 1 This allows you to send an X10 module command 0 or 1 remotely by using Menu 4 Output Control on the NX 595E Drop down Event Output 1 trigger 0 Output 2 trigger 1 NX 595E Installation Manual X10 Module Number 31 Activation Event Select the reguired event from the drop down list that will activate the corresponding relay Activation Time Time the relay will be active options 0 255 Minutes On if output should be timed in minutes off if timed in seconds Latch On if output should latch off if output should be timed Code Reset On if output should stop timing upon code entry off if output should follow timer Open Schedule On if output should only activate between the opening and closing time Close Schedule On if output should only activate between the closing and Opening time Invert On if output should be inverted Activation Partitions Is used to select the partition s th
33. pass 2 4 Event History 2 4 1 Alarm Memory 2 4 2 Event History Intercom Control 3 1 Listen In 3 2 Two way communication E Output Control 5 Message Bank 5 1 Record an Exit Message 5 2 Record an Entry Message System Configuration 0 1 User Configuration 0 1 1 User Pin 0 1 2 User Partition 0 1 3 User Authority 0 2 Time and Date 0 2 1 Time 0 2 2 Date 0 3 Partition Entry Time 0 4 Partition Exit Time 0 5 Phone number configuration 0 5 1 Alarm Phone Number One 0 5 2 Alarm Phone Number Two 0 5 3 Alarm Phone Number Three 0 5 4 Divert Phone Number One 0 5 5 Divert Phone Number Two 0 5 6 Divert Phone Number Three gt 0 5 0 Service provider phone Installer access only number 0 6 Voice Message 0 6 1 Exit message 0 6 2 Entry message 0 6 3 User name 0 6 4 Zone name 0 6 5 Partition name 0 6 6 Output name 0 6 7 Room name 20 NX 595E Installation Manual 0 6 8 System name gt 0 0 Panel and device configuration Installer access only Main Menu Additional Installer Information Output Control The two onboard relays are defaulted as Door 1 and Door 2 control and are controlled when an intercom session is established between an outdoor station and NX 181xx Voice keypads Relay trigger events are selectable and can be chosen from a drop down Activation events list from within the web interface Events can only be selected from within the NX 595E web interface Note From the activation event drop down list ou
34. r a long ring period This segment is used to set the answering machine defeat feature and enable a connection to the NX 595E before the answering machine answers the incoming call When answering machine defeat is enabled accessing the NX 595E remotely is accomplished by calling the phone number the NX 595E is connected to and allowing it to ring once or twice then hanging up Wait 10 seconds Then calling back the NX 595E which will now answer the next incoming call The second call must be made within 60 seconds of the first Call Segments 2 amp 3 are reserved 1 Zone doubling E E 38 NX 595E Installation Manual Location 2 Number of Rings Location 2 contains the number of rings the NX 595E must detect before answering the telephone line when initiating a communication session A value of 1 15 can be entered in this segment Generally rings to answer would be disabled when enabling answering machine defeat Location 3 Dial Attempts Location 3 is used to enter the number of dial attempts the NX 595E will make before ending the communication cycle A value from 1 15 may be used and the default is 6 Location 4 Voice Reporting Features Event Selection for all Voice dialing numbers Segment 1 some Segment 2 System Trouble and restores Siren Phone Expander Short Circuit Failure to Communicate CWN Sensor Lost or Sensor Low Battery ca Program mode Download and Log Full full log must be en
35. ra ra fe ww aln E aa ra Je s oa a Ja i NX 595E Installation Manual 41 Location 17 Divert Phone Number Three 3 The third Divert phone number is programmed in Location 17 Call divert phone number 3 will be dialed if call divert phone number 2 is busy when a call is initiated from an outdoor station The outdoor station must be interfaced with the NetworX security system via the NX 595E The NetworX security system must also be in the armed condition 15 Pulse dialing in the segment where pulse dialing should begin 14 Indicates the end of the phone number 13 Creates a four second delay 12 11 a Location 18 Zone Starting Number Location 18 is used to enter the starting zone number of the additional zones on the NX 595E The two zones can also be zone doubled please refer to Location 1 to enable the zone doubling feature 0 Disabled CSCI ISON 105 108 17 1 7 20 49 49 113 116 29 20 28 0 Se 121 124 33 33 36 65 Note Additional zones are only available on the NX 8E This feature is not available for NX 4 or NX 8 panels Segment 1 Location 19 IP Feature Options Location 19 is used to set required network settings Enable DHCP DHCP or Dynamic Host Configuration Protocol is a computer network protocol used by devices to obtain configuration information for operation in an Internet Protocol network This protocol reduces system administration workload allowing
36. s At default the NX 595E programming menus are only available when the NX 595E is in program mode e g you enter the device programming menu via a keypad connected to the Networx system Location 20 IP Gateway Location 21 NX 595E IP Address Location 22 Subnet Mask Navigating to the NX 595E Enter the IP address of your NX 595E into the web browser to access the NX 595E Configuration Server Note You may also connect using SSL or Secure Sockets Layer by typing https instead of http for higher security communications between your browser and the NX 595E SSL connections may be slightly slower due to the encryption process You will also receive a warning window There is a problem with this websites security certificate choose Continue to this website to connect to the NX 595E 24 NX 595E Installation Manual Figure 9 Certificate Error Navigation Blocked Windows Internet Explorer E v https 10 89 3 129 File Edit view Favorites Tools Help Sign in Page Sign in Enter your username installer Enter your password E When successfully connected the NX 595E will display the Sign in Page Enter the correct username password combination to login e Default Installer Username installer username is case sensitive e Default Password 9713 enter the NetworX panel programming code The default installer name can be changed on the Location Setup menu after you ha
37. security system has detected a problem with the phone line Expander Low battery A remote power supply s back up battery requires charging AC power fail A remote power supply has lost its electricity power Box tamper An expanders cabinet tamper input has activated A6 NX 595E Installation Manual Keypad Fire alarm A fire alarm has been activated at the keypad Panic A panic alarm has been activated at the keypad Medical A medical alarm has been activated at the keypad NX 595E Installation Manual 47
38. tation may not apply to you In any event the total liability of UTCFS shall not exceed the purchase price of the product The foregoing limitation will apply to the maximum extent permitted by applicable law regardless of whether UTCFS has been advised of the possibility of such damages and regardless of whether any remedy fails of its essential purpose Installation in accordance with this manual applicable codes and the instructions of the authority having jurisdiction is mandatory While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents UTCFS assumes no responsibility for errors or omissions Advisory messages Advisory messages alert you to conditions or practices that can cause unwanted results The advisory messages used in this document are shown and described below WARNING Warning messages advise you of hazards that could result in injury or loss of life They tell you which actions to take or to avoid in order to prevent the injury or loss of life Caution Caution messages advise you of possible equipment damage They tell you which actions to take or to avoid in order to prevent the damage Note Note messages advise you of the possible loss of time or effort They describe how to avoid the loss Notes are also used to point out important information that you should read Keep in mind the level of security you will obtain with this system relates specifically wi
39. tem configuration menu Press 0 for panel and device configuration Select a device number followed by Device Is now connected and you are now ready to begin programming 1 star moves back to panel and device configuration 2 star moves back to system configuration menu 3 star moves back to main menu Disconnects session The above steps presumes you have exited any location menus within the device you are connected NX 595E Installation Manual 23 Accessing the NX 595E via the Web pages Find the IP Address DHCP is enabled by default which means an IP address will be assigned automatically if your network supports DHCP To discover the IP address use a keypad connected to the alarm system enter program mode and navigate to device 191 Location 21 Set the IP Address If the IP address is empty Location 21 Segment 1 will be 0 then program the relevant locations below Location 19 IP Location Settings e Enable option 1 to turn on DHCP which will allow your router to assign the NX 595E and IP address automatically Disable this option to manually assign an IP address e Enable option 2 to force SSL connections turn off to allow either standard or SSL connections e Enable option 4 to allow ping command for troubleshooting e Enable option 5 to allow the clock to automatically update using an internet time server e Enable option 6 to always allow remote access to the NX 595E programming menu
40. th two major factors e The quantity quality and placement of security devices attached to this security system e The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system This product is to be installed by qualified SERVICE PERSONNEL only NX 595E Installation Manual 5 The eguipment should only be operated with an approved power adapter with insulated live pins Caution Risk of explosion if battery is replaced by an incorrect type Dispose of batteries according to the instructions Contact your service provider for replacement batteries Disclaimer A level of TCP IP knowledge is required by the installer s to set up some of the NX 595E functionality UTCSF limits it support to NX 595E setup only and is unable to offer further assistance on your client s DSL modem router firewall or any other 3 party software Please consult your customers IT department or qualified IT professional about implementing this product onto your client s network Warranty UTC Fire amp Security Americas Corporation Inc guarantees this product against defective parts and workmanship for twenty four 24 months from the date of purchase lf any defect appears during the warranty period contact your service provider UTC Fire amp Security Americas Corporation Inc assumes no liability for consequential or indirect damage and accepts no responsibility for repairing damage to the pr
41. the phone number you wish your clients to call for servicing this number will be announced via your NX 181xx Voice keypads each arming and disarming cycle whilst a system fault is present How to Enter Service provider phone number Step 22 Example TF PIN pagg Phone No EJ ja a fa Enter service provider phone numbers Call the NX 595E via an offsite touch tone phone to begin the session Press 0 for system configuration menu Press 5 for phone number configuration Press 0 for service provider phone number Select a new alarm divert phone number followed by 1 star Move back to step 3 phone number selection 2 star moves back to system configuration menu 3 star moves back to main menu Disconnects session System Configuration 0 1 User Configuration 0 2 Time amp Date 0 3 Partition Entry Time 0 4 Partition Exit Time 0 5 Phone number configuration 0 6 Voice message recording l gt 0 0 Panel and device configuration NX 595E Installation Manual Panel and device configuration This is the access point to program all other devices that are on the Networx bus such as the control panel radio receivers output modules etc How to Record an Exit message Step Example the TF PIN 2 jojo 3 i je 4 BEEG To record a new eit message from the Voice message recording menu Call the NX 595E via an offsite touch tone phone to begin the session Press 0 for sys
42. tion menu is where user PIN codes are assigned to users The authorisation level determines the options available to that user user authorisation is where you would alter and increase a users authority to become a Master Code Master codes can only create delete or modify user codes with equal or less authority than themselves The user configuration menu is where you also assign partition control and adjust authorisation levels to each user Assigning partitions to users determines which sections partitions of the security system a user may access Important You must create a user name for your customer to enable them to login to the NX 595E The installer account is for installer access only Write the user name and PIN code on the back page of the User Manual 26 NX 595E Installation Manual Network Settings Network Settings Logout Gave Confi MAC Address 00 04 43 13 09 85 Sensors History Enable DHCP Ll Require SSL Users Enable Web Update Email Reparting Enable Ping Enable Web Time Updates SMS Reporting Enable Hills Protocol Server Enable xConnect voice Reporting IP Address eke Ten 1 171 Call Divert Gateway 192 168 1 1 Feature Setup PIE Make 255 255 255 0 Primary DNS Network Settings EU Secondary ONS logo Outputs EN IP Reporting Web Access Passcode yo 45R7q xConnect Server 1 your_service 1 com 443 xCnnnect Server 2 your_service2 com 443 oave Config MAC Address Media Access
43. tput 1 trigger and output 2 trigger are fixed X10 module commands 0 and 1 When selected they can be controlled directly from within Menu 4 output control when connected to a NX 595E Drop down Event X10 Module Number Output 1 trigger 0 Output 2 trigger 1 Additional relay boards NX 507 can be added with a system total of 16 An output from a NX 181xx or NX 595E is an X10 command that can be tied to different relays Set the relay you wish to control to follow event 56 follow X10 command Then tie the relay to the output by setting the corresponding X10 module number from the chart below at the X10 address for the relay Please refer to your NX 507 installation instructions for further details Note NX 508 output boards can also be used X10 Module X10 Module Outputs Number Outputs Number 1 0 9 8 2 1 10 9 3 2 11 10 4 3 12 11 5 4 13 12 6 5 14 13 7 6 15 14 8 7 16 15 o System Configuration 0 1 User Configuration NX 595E Installation Manual 21 0 2 Time amp Date 0 3 Partition Entry Time 0 4 Partition Exit Time Ly 0 5 Phone number configuration 0 5 1 Alarm phone number One 0 5 2 Alarm phone number Two 0 5 3 Alarm phone number Three 0 5 4 Divert phone number One 0 5 5 Divert phone number Two 0 5 6 Divert phone number Three l gt 0 5 0 Service provider phone number 0 6 Voice message recording 0 0 Panel and device configuration Service provider phone number Menu 0 5 0 This is
44. uently Asked Questions 16 xTun Cloud Service Error Bookmark not defined Loading Factory Defaults device 191 17 Using a NX 181xx Voice keypad 18 Using a Standard Keypad Icon or LCD 18 Enrolling the NX 595E 19 Accessing the NX 595E via a Touch Tone Phone 19 Main Menu Structure 20 Main Menu Additional Installer Information 21 Output Control 21 Service provider phone number 22 Panel and device configuration 23 NX 595E Installation Manual Accessing the NX 595E via the Web pages 24 Find the IP Address 24 Set the IP Address 24 Navigating to the NX 595E 24 Signin Page 25 Main Menu Web Accesssed with Installer Code 25 Users 26 Network Settings 27 Feature List 29 Outputs 31 IP Reporting 33 Enable Remote Web Access 34 Access via Android App 35 Access via iPhone App 36 Troubleshooting 36 Worksheets 38 System Status Messages 46 NX 595E Installation Manual Important information Limitation of liability To the maximum extent permitted by applicable law in no event will UTCFS be liable for any lost profits or business opportunities loss of use business interruption loss of data or any other indirect special incidental or consequential damages under any theory of liability whether based in contract tort negligence product liability or otherwise Because some jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages the preceding limi
45. ve logged in Main Menu Web Accesssed with Installer Code Arm Disarm Ready Sensors History Ws Ry l J S Users Away Stay Off Chime Email Reporting SMS Reporting Voice Reporting Call Divert Feature Setup Network Settings Outputs IP Reporting NX 595E Installation Manual 25 The screen shot above shows the NX 595E s complete menu when accessed via an installer code Network settings location list outputs and IP reporting will not be presented when accessed via a master code and only Arm Disarm and Sensors will display If a standard user code is used to access the NX 595E Make your programming selection by clicking on one of the left tabs Note The NX 595E must either be in program mode or alternately Location 19 Option 6 must be enabled before the NX 595E will present network settings location list outputs or IP reporting even when accessed via an installer code Users Configure Users Logout Select a User Userl Arm Disarm Displaying User EE NN ub ubeL Sensors Name Usert History PIN 1234 Pin Digits Total Users n Email Reporting l User Authority SMS Reporting CJ Arm Only Voice Reporting L Schedule C Master Call Divert Arm Disarm Bypass Feature setup Report C Reserved Network Settings CO Reserved Outputs User Areas Marea 1 MArea MArea3 MArea 4 IP Reporting Mareas MArea6 MArea MaAreas Clear User Save User The user configura