Home

User manual MAX88-88D-816-816D_UK

image

Contents

1. Previous Select previous audio source Q Stop Stop monitoring and release zone 8 and 16 o Monitor otart monitoring and Block zone 8 and 16 Next select next source BMI MusiCall user manual Mug Technical Specifications AUDIO INPUTS INPUT 1 8 Signal levels berate mE use dae 0 dBu impedaNCE oin 10 kOhm INDULNOlSe en ee 8 dB IHF A Crosstalk between inputs esee 72 dB 1kHz Input attenuators sacii 0 25 dB steps of 0 5 dB HeadroOI ueri 10 dB AUDIO OUTPUTS OUTPUT 1 16 Signallevel rnrannnrnnnevrnnnnvannnevandnvnnnsvennnevnne 0 dBu pedan E ee 150 Ohm Main volume adjust u0224002240 Renee nene nenne 0 50 dB steps of 0 5 dB Output volume adjustment 0 50 dB steps of 0 5 dB then mute 75 dB TR DEN HR 0 08 CCIR RMS OdBu FREQUENCY RESPONCE IABULTO OUIDUT Eee 25 Hz 25 kHz 1 dB WALLUNIT CONNECTION 010119 10 118 VON AG ee 24V Maximum output current ssesse 110mA automatic fuse CONSOLE CONNECTORS Output voltage sisser nea aa 24V Maximum output current ssssesssss 500mA automatic fuse COMMUNICATION Baudrate RS232 esee 14kbps USB USB2 Ethernet EN 10 100MBit auto select GENERAL Mains supply Input voltage isein aaa 230 VAC 10 50 Hz POW CR ON TOR CUT 70 W DIMENSIONS Central unit msnm LES 483 x 132 mm B x H 19 3HE Boi
2. Audio inputs AUDIO INPUTS The Matrix allows to connect several audio inputs TUM like CD players MP3 players computers or o 0 satellite receivers 0060 5B Zone control To control the different audio zones en nn NE FE TOR wall controllers can be connected to the ar matrix Using these controllers each zone can select an audio source and set it s desired volume Further more two paging consoles can be connected Audio outputs The audio outputs are standard unbalanced line ag level signal These outputs can be used to o connect the distribution amplifiers for each ao zone Using 100 volt amplifiers multiple speakers can be connected to a single zone Remote inputs Each matrix has five remote connections and a priority REMOTES telephone audio input Three inputs can be used to activate ELEzEETZ room combining One input can be used to activate the priority BEBE BELBELRE LING audio input The last input can be used to connect an external ie system mute for fire alert and evacuation purposes The telephone audio input can be configured to auto answer or audio detect Logic IO Using the logic IO paging can be remotely activated The logic output scan be configured to externally activate signals or relays The I O connection can be set to groups 1 8 or 9 16 Configuration The matrix can easily be configured and controlled using a qe computer or tablet For this the MAX matrix must be M gt o
3. Musical ser manual MAX 8 8 MAX8 8D MAX8 16 MAX8 16D DJAJTJEJQ auko Cecknolagres BMI MusiCall user manual Notes MusiCall user manual ETG Safety instructions 1 2 3 4 5 10 11 12 13 14 15 All safety instructions warnings and operating instructions must be read first All warnings on the equipment must be heeded The operating instructions must be followed Keep the operating instructions for future reference The equipment may never be used in the immediate vicinity of water make sure that water and damp cannot get into the equipment The equipment may only be installed or fitted in accordance with the manufacturers recommendations The equipment must be installed or fitted such that good ventilation is not obstructed in any way The equipment may never be installed in the immediate vicinity of sources of heat such as parts of heating units boilers and other equipment which generates heat including amplifiers Connect the equipment to a power supply of the correct voltage using only the cables recommended by the manufacturer as specified in the operating instructions and or shown on the connection side of the equipment The equipment may only be connected to a legally approved earthened mains power supply The power cable or power cord must be positioned such that it cannot be walked on in normal use and objects which might damage the cable or cord cannot be placed on
4. DAB FM QUAD Tuner The MAX8 8D and MAX8 16D are equipped with a quadruple DAB FM and a single web stream tuner Using the touch screen display control is made possible Adding to the tuner functionality monitoring all sources though the headphone is made possible and vital information about the system can be reviewed anne MAX 8 16D Antenna For use of the four tuners the system has to be connected to a CA PINN Central Antenna Installation or external outdoor antenna For the use of 14 DAB an external antenna is necessary when a CAI installation does not 2 provide DAB When using the Web stream encoder the matrix needs to O be connected to a local area network with internet access Booting During the First 15 seconds after booting the boot screen logo will I CALL appear During this time all available information about the matrix setups radio stations and web streams is loaded DAB FM QUAD TUNER PEDATEI DAB FM tuner Monitoring the tuner is made possible within the AY ge Tuner tab Ihe desired tuner can be selected Switching between DAB and FM is only made Bb possible within the configuration pages and can Sion FE not be changed using the front panel display Fregeney 102 40 43 dBuW JAZZ FM Flevoland Adjusting the tuners frequency or preset will affect O MUSIC the zones that have selected the tuner as source N Control Using the front panel display all available stations and
5. it or against it Special attention must be paid to the point at which the cable is attached to the equipment and where the cable is connected to the power supply Ensure that foreign objects and liquids cannot get into the equipment The equipment must be cleaned using the method recommended by the manufacturer If the equipment is not being used for a prolonged period the power cable or power cord should be disconnected from the power supply In all cases where there is a risk following an incident that the equipment could be unsafe such as if the power cable or power cord has been damaged e if foreign objects or liquids including water have entered the equipment e if the equipment has suffered a fall or the casing has been damaged if a change in the performance of the equipment is noticed it must be checked by appropriately qualified technical staff 16 The user may not carry out any work on the equipment other than that specified in the operating instructions DIAITIEIQ audio technologies BI MusiCall user manual Introduction MusiCall central matrix DAB FM QUAD TUNER The Musicall paging system is an audio distribution system capable of distributing multiple sources into 8 or up to 16 independent zones Using the control units MRC or the internal webpage each zone can remotely select it s own audio source and volume setting Matrix models The MAX series matrices are available in four mod
6. C Jo connected to the local LAN network Ethernet cro Rm Using the RS232 communication port external home automation can be connected The USB connection is available for service purposes only Link LINK 1 LiNk 2 Through the link interface multiple MAX8 16 and 8 16D matrices can be connected making paging possible trough out the complete system BMI MusiCall user manual User control Wallunits MRC3 MRCA The wallunits are placed into the different rooms zones and are connected using a two wire connection to the matrix The wallunits are placed into a standard flush box MRC3 or can be mounted onto the wall MRCA Using these wallunits users can access volume control and audio source selection MRA1 MRA2 When using an local audio input in a zone a microphone CD player or laptop can be connected to the matrix By pressing Channel and Channel on the wallunit the local audio input is automatically selected The local audio input can also be made public available for use through out all zones WEB The MAX matrices offer full control over IP using the internal webserver Users can access the individual zone page or global control all zones The interface allows audio source selection volume control and EQ settings Zones can be locked for webcontrol using a simple four digit code The internal webpage can be accessed using http musicall or by entering the IP address of your mat
7. DS or meta data can bes end to the wallunit displays Local audio input Using the local audio input MRA1 or MRA2 an external audio source like an MP3 player microphone laptop or mixing desk can be added to the system The MRA1 is equipped with a balanced audio input on XLR This way a microphone can easily be connected For connecting a m CD player or other RCA sources a conversion cable must be connected Using the Mic Line switch the input sensitivity can be adjusted Set is to line when line level signal is present The MRA2 is equipped with both balanced XLR and RCA line level inputs Each input can be independently adjusted making a small mix between line and microphone on the same input The Clip Ovl LED will blink on overloading the input signal BI MusiCall user manual Consoles Paging zones Each button contains a zone or number off zones that can be changed using the configuration website On addressing a zone the LED turns red At this point the chime is heard On the LED turning green a voice call can be made On releasing the zone button the zone returns in the state it was before paging started a e n case room combining is active and a slave zone is addressed but not the master zone paging will not be active in that specific slave zone e n case room combining is active and a master zone is addressed all slave zones will be addressed too e Paging to a zone will always be active even when
8. P 215 mm WNEION Seesen 5 3 kg Netto pr MusiCall user manual ETG Product support For questions about the Musicall system parts and other products you can contact your local dealer or Dateq Audio Technologies B V De Paal 37 Telephone 0031 36 54 72 222 1351 JG Almere Fax 0031 36 53 17 776 The Netherlands E mail infoQmusicall ni Internet www musicall nl
9. a zone is set to silence e Paging will not be active when a system mute by fire alert or evacuation is active Adjusting configuration Using the console group paging can be set and adjusted Programming through the paging console only groups A B C and D are available Groups 1 8 or 1 16 can only be changed using the configuration pages By default these groups are set to zone 1 16 Entering the programming menu Press the P key to enter the programming menu The programming screen will appear By default the programming menu will start in group A Select the group that needs to be changed In programming mode the buttons 1 16 indicate all zones The green LED s indicate the active zones in the selected group Zones can be added by pressing the zone buttons 1 16 In case a zone is selected stereo both zone outputs are automatically selected when adding the zone Selected zones and groups are automatically saved into the matrix configuration Existing paging groups can later on easily be changed by pressing one of the group buttons All zones within the selected Group will light up green By pressing the buttons 1 16 zones can be added or removed A zone can be selected to one or more groups Paging groups are automatically stored Groups 1 16 can only be changed using the internal configuration webpage Paging to the master of room combined zones are active in slave zones too BMI MusiCall user manual
10. els The MAX8 8 is the standard central matrix Model with 8 stereo mono zones 8 stereo 16 mono RCA inputs and optional 8 local audio inputs Each can be equipped with it s own MRC wall controller and MRA local Musicall MAX8 8 audio input Configuration and control possible using the internal webserver The MAX8 8D is the DAB central matrix equipped with a quadruple DAB FM and WEB tuner Model with 8 stereo mono zones 3 stereo 6 mono RCA inputs and optional 8 local audio inputs Each can be equipped with it s own MRC wall controller and MRA local audio input Configuration and control possible using the internal webserver MUS fetes Musicall MAX8 8D The MAX8 16 is the standard central matrix Model with 8 stereo 16mono zones 8 stereo 16 mono RCA inputs and optional 16 local audio inputs Each can be equipped with it s own MRC wall controller and MRA local audio input Configuration and control possible using the internal webserver Musicall MAX8 16 De MAX8 16D is the DAB central matrix equipped with a quadruple DAB FM and nn on WEB tuner an E Model with 8 stereo 16mono zones 3 stereo 6 mono RCA inputs and optional 16 local audio inputs Each can be equipped with it s own MRC wall controller and MRA local Musicall MAX8 16D audio input Configuration and control possible using the internal webserver MusiCall user manual BTG Matrix connections 00000000 gt 200000 0000 90 28 3B 48 58 68
11. presets can be monitored Seek down The tuner will select the last in list radio station Previous The tuner will select the previous preset Next The tuner will select the next preset Seek up The tuner will select the next radio station Signal Signal strength for the selected tuner MusiCall user manual ETG Web encoder Within the Web tab all preset stream sources can p be monitored After selecting the desired web Tuner web max into 3 stream the encoder will connect to the stream ENS NE bi server and monitoring can be done using the front emer WEB Radio classic panel headphone connection ER ENS WEB Radia 3 n WEB Radio 4 ll Adjusting the web stream source will affect all szene zones that have selected web stream as source Wee WEB ETY NH www Streaminghostivebstreamt high may Control Using the front panel display all pre configured web streams can be monitored Previous Select previous preset Q Stop Stop playout Q Play Start playout Next Select next preset MAX Matrix Within the MAX tab all available audio sources ail within the MAX Matrix can be monitored Using the MMR monitor functionality all sources can easily be 14 bi adjusted during installation or trouble shooting purposes During monitoring the MAX sources the audio outputs 8A zone 8 and 8B zone 16 are not available Control Using the front panel display all available matrix sources can be monitored
12. rix into the webbrowser Individual zones can be reached by http musicall nameofzone or by entering http matrixIP nameofzone Consoles P E AA Es Vs 1 ZIELE LH 16 1748 P rv 3 c MPC 16 A V 1 27 K r Ae MCN GP GE 9 10 w 412 13 14 15 16 D MPC3 MPC16 The paging console are used to address individual zones or groups of zones These groups can be programmed using the paging console The console is connected to the matrix using a four wire link None of the Musicall controllers consoles or audio inputs need external power supply All power is supplied through the MAX matrix MRC MRA MusiCall user manual ETG Control WallUnits The audio source for a zone can be selected by pressing channel or channel The number of sources and sequence depends on the matrix configuration By pressing the channel and channel simultaneously the local audio input will be selected Adjusting the volume for a zone is done by pressing volume or volume By holding the button volume can be increased or decreased Pressing both and buttons at the same time will mute the zone Paging to the zone is always available e When room combining is active slave zones are not able to select the audio source Setting the source is only available for the master zone Slave zones do have the possibility to adjust volume e On the MAX8 8D en MAX8 16D R

Download Pdf Manuals

image

Related Search

Related Contents

Wireless Mouse M505 User Manual  AKE 35-19 PRO AKE 40-19 PRO  Impact-E 52 User Manual (Issue B) Part No: 85080839  Capture Pro Software  LED SAKURA 12/21 防水型照明器具 取扱説明書    WAREMA Brise soleil orientable et store vénitien extérieur Avec  MFP_Extraction guide tourisme  P6172 A3 User`s Manual  Document  

Copyright © All rights reserved.
Failed to retrieve file