1. User Manual Installation Operation Omniksol 1 5k TL Omniksol 2k TL Omnik New Energy Co ltd CATALOG d 1 1 1 2 1 3 2 2 1 2 2 3 3 1 3 2 3 3 4 4 1 4 2 4 3 4 4 5 5 1 92 5 3 5 4 5 5 6 6 1 6 2 6 3 6 4 6 5 6 6 T 7 1 7 2 7 3 Notes on this vu EE 1 Scope of Validation eee EE EE 1 Symbols Used eee 1 Target Group A 1 Preparation eE eee ee EEE ees 3 Safety Instructions 5 E E EEE 3 Explanations of Symbols on Inverter ee sree eee eee cence ee eres 5 Product Information oe oe ee ree 6 a EE 6 Major Characteristics eeee reece ree eee neers 7 R I E SEET 8 Packing Checklist 000e eee e ee 10 Assembly parts orc reece rece ee EE Eee 10 Product Appearance ep 11 Product Identification EE 12 Further Information e ase eiieeii ina aE EE rans EEE EEEE EEEE EREA 12 instalation seer eae ee eee ere E 13 Safety EE 13 Mounting Instructions gt s eee eee eee ee nets 13 Safety Clearance EEE 14 Mounting Procedure sss eee reece eee ee eee eee eens 15 Safety lock eccc cree etree eee eee 16 Electrical Connection 25th wee hee nee ee tee eh 18 Safety E 18 Overview of Connection Area eege 18 AC Side Connector ET 19 DC Giele Connection aaea E E E wes 20 DC Side Disconnection EE 23 Communication and Monitoring Device seep eee eee EE E EE E 23 Display eee 25 Bert 25 LCD EDICI EVA 26 Set Language Sech eg EE E A Ra lane STR TR E E O E 27 ZA 10 11 e Gel a lel
2. Euro efficiency at 360VDC 96 6 MPPT efficiency 99 9 Internal overvoltage protection Yes Page 8 NIT User Manual Earth fault protection Yes According to VDE 0126 1 1 RD1663 ENEL2010 C10 11 Earth fault current monitoring G83 1 AS4777 Islanding protection According to VDE 0126 1 1 RD1663 G83 1 AS4777 EN 62109 EN 61000 6 1 EN 61000 6 3 EN 61000 6 2 EN 61000 6 4 EN61000 3 2 EN61000 3 3 EN61000 3 12 EN61000 3 CE compliant according to 11 Dimensions WxHxD mm 330x425x130 IP protection type IP 65 according to IEC 60529 Relative humidity 0 to 98 no condensation Noise level dBA lt 40 Isolation type Transformerless Housing Metal housing for inside and outside installation LED display 3 Data logger Data communication interfaces RS485 Optional Wi Fi GPRS Ethernet Standard warranty 5 years optional 10 years Page 9 ur A User Manual 4 PACKING CHECKLIST 4 1 Assembly parts After you receive the Omnik inverter please check if there is any damage on the carton and then check the inside completeness for any visible external damage on the inverter or any accessories Contact your dealer if anything is damaged or missing I pee o Installation and operating instructions DC Switch Optional SS Expansion tube Page 10 unik User Manual 4 2 Product Appearance e Front Bus A e fiom LED light Red FAULT o
3. eaer Monitoring LCD with backlighting e Bottom Page 11 unik User Manual Tout waren Plug connectors for DC input 8 RS232 RS485 interface Terminal for grid connection AC output 4 3 Product Identification You can identify the inverter by the side name plate Information such as serial number SN type of the inverter as well as inverter specifications are specified on the side tname plate The name plate is on the middle part of the right side of the inverter housing And the following figure is the side name plate example as on Omniksol 1 5k TL uv www omnik olar com Type Omniksol 1 5k TL DC MG man Sev N D sad 36 DM Voc app 120 A BEIM BG mun 1750 loc mom 14A G ma 15 4 AC NAE son SEA fac nan SOHz Pac mum iv dh Pug mae 1550 lac pap SG D i lac man BA cost 1 IP GS outdone Goes L bh oe ASU ARITI 3 3 G85 B S A A AC CE e s S12 6305 6676 E mail s rvinegomnik solarcam Binghy Fd Ho C38bobar Pere Ad 4 205123 Bure Chink amp 4 4 Further Information If you have any further questions concerning the type of accessories or installation please check our website www omnik solar com or contact our service hotline Page 12 ur A User Manual 5 INSTALLATION 5 1 Safety DANGER DANGER to life due to potential fire or electricity shock DO NOT install the inverter near any inflammable or explosive items This inverter will be direct
4. features and functions WARNING Do not use this product unless it has been successfully installed by qualified personnel in accordance with the instructions in Chapter 5 Installation Chapter 5 and Chapter 6 are only for qualified personnel who are intended to install or uninstall the Omnik Grid Tie Solar Inverter qd NOTICE Hereby qualified personnel means he she has the valid license from the local authority in e Installing electrical equipment and PV power systems up to 1000 V e Applying all applicable installation codes e Analyzing and reducing the hazards involved in performing electrical work e Selecting and using Personal Protective Equipment PPE Page 2 ur A User Manual 2 PREPARATION 2 1 Safety Instructions DANGER DANGER due to electrical shock and high voltage DO NOT touch the operating component of the inverter it might result in burning or death TO prevent risk of electric shock during installation and maintenance please make sure that all AC and DC terminals are plugged out DO NOT stay close to the instruments while there is severe weather conditions including storm lighting etc WARNING The installation service recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations Please contact your dealer to get the information of authorized repair facility for any mai
5. has occurred Please go to Part 10 Trouble Shooting to remedy the error This device SHALL NOT be disposed of in residential waste Please go to Part 9 Recycling and Disposal for proper treatments g Without Transformer This inverter does not use transformer for the isolation function German mark of conformity The inverter complies with the requirement of the German Grid Regulations Certified Safety The inverter complies with the requirements of the Equipment and Product Safety Act in Europe Standards Association of Australian The inverter complies with the requirement of the AS4777 CE Mark Equipment with the CE mark fulfils the basic requirements of the Guideline Governing Low Voltage and Electromagnetic Compatibility No unauthorized perforations or modifications Any unauthorized perforations or modifications are strictly forbidden if any defect or damage device person is occurred Omnik shall not take any responsibility for it Page 5 ur A User Manual 3 PRODUCT INFORMATION 3 1 Overview e Industrial Layout Page 6 NT User Manual s Excellent Heat Elimination 3 2 Major Characteristics Omnik inverter has following characteristics which make Omnik inverter High Efficiency High Reliability High Cost Effective Ratio e Wide DC input voltage and current ranges enables more PV panels connected e Wide MPP voltage range ensure high yield under variou
6. 4 Disconnect ALL PV or PV EEPROM RW 2 Wait for a few seconds 3 After the LCD switches off reconnect and check again SCI Failure 4 If the problems remain please call local service AC HCT Fault GFCI Failure ur A User Manual 10 CONTACT Suzhou Headquarter Xinghu Road No 218 bioBAY Park C2 101 215123 Suzhou China Tel 86 512 6295 6676 Fax 86 512 6295 6682 Email info omnik solar com www omnik solar com Service line Tel 86 512 6295 6676 Fax 86 512 6295 6682 Email service omnik solar com www omnik solar com Page 31 User Manual Ovni ik 11 ABBREVIATION LCD Liquid Crystal Display LED Light Emitting Diode MPPT Maximum Power Point Tracking PV Photovoltaic Vdc Voltage at the DC side Vac Voltage at the AC side Vmpp Voltage at the Maximum Power Point Impp Amperage at Maximum Power Point AC Alternating Current Form of electricity supplied by Utility Company DC Direct Current Form of electricity generated by PV modules VDE 0126 1 1 German standards for establishing suitability for Grid Connection of the Inverter DC Switch Switch in the DC Circuit Disconnects DC source from Inverter May Page 32 be integrated or external to Inverter
7. D Panel A B C D el See e meaa R The LCD panel is integrated in the front lid of the inverter so it is easy for user to check and set the data In addition the user can press the function key to illuminate the LCD screen EI NOTICE Omnik inverter is not an aligned measuring instrument for current voltage or power consumption A slight deviation of a few percent points is intrinsic to the system the results from the inverter cannot be used for grid balance calculations An aligned meter will be required to make calculations for the utility company Page 25 NIT User Manual 7 2 LCD Display EI NOTICE Make sure the DC switch Optional is switched to On position otherwise the inverter cannot work due to power shortage The display content consists of 2 lines The bottom line Line 2 always displays the output power Pac xxxx W The top line Line 1 shows current state information by default and by pressing function key it will display different operating information as the following flow chart and table State information Pac xxxx W E today Pac xxxx W E total 9 l Z lt Q lt Pac xxxx W ke Pac xxxx W Di CH Pac xxxx W Frequency Pac xxxx W Pac xxxx W lt 9 l Z SetLanguage Pac xxxx W Vac Pac xxxx W Page 26 NIT User Manual ee ee State Current state information all possible content show
8. a Re ee eee er re een care er etre er ye ees 28 Recycling and Disposal seep EEE eerie eee te eee 29 Troubleshooting epep EEE EEE 30 Contact EE 31 Abbreviation EE 32 ur A User Manual 1 NOTES ON THIS MANUAL 1 1 Scope of Validation The main purpose of this User s Manual is to provide instructions and detailed procedures for installing operating maintaining and troubleshooting the following two types of Omnik New Energy Solar Inverters e Omniksol 1 5k TL e Omniksol 2k TL Please keep this user manual all time available in case of emergency 1 2 Symbols Used A DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided can result in death or serious injury or moderate injury CAUTION CAUTION indicates a hazardous condition which if not avoided can result in minor or moderate injury or moderate injury NOTICE NOTICE indicates a situation that can result in property damage if not avoided 1 3 Target Group e Chapter 1 2 3 4 7 8 9 10 11 and Chapter 12 are intended for anyone who is intended to use Omnik Grid Tie Solar Inverter Before any further action the operators must Page 1 NIT User Manual first read all safety regulations and be aware of the potential danger to operate high voltage devices Operators must also have a complete understanding of this device s
9. e requirement Min S10 N 70 Los Min 450 N 100 Lbs e Insert contact cable assembly into back of male and female connector A click should be heard or felt when the contact cable assembly is seated correctly Please see below figures Female side connector F Page 22 User Manual Male side connector M f Wrest the cap by using the torque of 2 6 2 9NM g Plug the DC connectors to DC terminal on Omnik sol 6 5 DC Side Disconnection When the separation of DC connectors is necessary please use the specified tool Ring tool or wrench tool to separate them While using the ring tool or wrench tool please make sure the wedge side of the fingers faces the female connector and push the tool down Then separate the connector by hand See below figures al R lll Separation by ring tool 6 6 Communication and Monitoring Device There are 2 plugs in the bottom side of the Omnik inverter as the following figure Page 23 NIT User Manual These 2 plugs are used for multipoint communications that is up to 50 Omnik inverters can be connected one by one through these 2 plugs and the cables the upper computer can communicate with these inverters via a single signal cable at the same time and maximum length of the cable is 1000m Through these plugs the user can get the data from these inverters and can also configure parameters of them Page 24 ur A User Manual 7 DISPLAY 7 1 LC
10. ect or disconnect the DC source from Inverter Page 20 unik User Manual For Omniksol 1 5k TL and Omniksol 2k TL there is only one MPP Tracker and the DC characteristics of them are illustrated as the following table Inverter Type Tracker DC Power DC Voltage DC Current Ommiksol t 5k TL 1 5k TL Omniksol 2k TL 1 The DC connectors come pre assembled and the caps are loose The whole connector will include the male side and female side as showed below Female side connector F Male side connector M 2 Assembly Instructions a Strip the cable with the length 0 276 inches 9 32 7mm and please be careful as Cable A6 inches 32 mm NOT to nick conductors b Use specified strip tool in this step Adjust the striper stopper and put the cable in corresponding notch to strip the length of 7mm Please see below figures Page 21 unik User Manual c Insert striped cable into contact barrel and insure all conductor strands are captured in the contact barrel and the conductors are visible in the contact barrel observation hole Please see below figures Pin contact Barrel observation hole conductor should be visible Socket contact Barrel observation hole conductor should be visible d Crimp contact barrel by using the hex crimping die Please see below figures Crimped pin contact Ges sachet contact Cable requirements Cable Size Cable pull out forc
11. isplay Possible actions Resumable Fault Permanent Fault Page 30 Check the impedance between PV amp PV and the inverter Isolation Fault is earthed The impedance must be greater than 2MQ Check whether the AC side has contacts with earth The ground current is too high After cut off the AC side connection unplug the inputs from the Ground Fault PV generator and check the peripheral AC system After the cause is cleared re plug the PV panel and AC connection and check PV Inverter status Grid Fault Wait for a moment if the grid returns to normal PV Inverter Fac Over Range automatically restarts Vac Over Range 2 Make sure grid voltage and frequency meet the specifications Grid is not connected Check grid connection cables Utility Loss Check grid usability If grid is ok and the problem persists maybe the fuse in the inverter is open please call service O The internal temperature is higher than specified normal value ver Find a way to reduce the ambient temperature Temperature Or move the inverter to a cooler environment Check the open PV voltage see if it is greater than or too close to 500VDC for Omniksol 1 5k TL or Omniksol 2k TL PV over Voltage If PV voltage is less than 500VDC and the problem still occurs please call local service Consistent Fault Disconnect PV or PV from the input restart the inverter Relay Check Fail DC INJ High
12. ly connected with HIGH VOLTAGE power generation device the installation must be performed by qualified personnel only in compliance with national and local standards and regulations EI NOTICE NOTICE due to the inappropriate or the harmonized installation environment may jeopardize the life span of the inverter Installation directly expose under intensive sunshine is not recommended The installation site MUST have good ventilation condition 5 2 Mounting Instructions Max 15 A gt Page 13 NIT User Manual Omnik inverter is designed for indoors and outdoors installation Please mount the inverter in the direction as illustrated above Install the inverter in the vertical direction is recommended with a max 15 degrees backwards For the convenience of checking the LCD display and possible maintenance activities please install the inverter at eye level Make sure the wall you selected is strong enough to handle the screws and bear the weight of the inverter Ensure the device is properly fixed to the wall It is not recommended that the inverter is exposed to the strong sunshine because the excess heating might lead to power reduction The ambient temperature of installation site should be between 20 C and 60 C between 4 F and 140 F Make sure the ventilation of the installation spot not sufficient ventilation may reduce the performance of the electronic components inside the inverter and shor
13. ntenance or repairmen Any unauthorized actions including modification of product functionality of any form will affect the validation of warranty service Omnik may deny the obligation of warranty service accordingly NOTICE Public utility only The PV inverter designed to feed AC power directly into the public utility power grid do not connect AC output of the device to any private AC equipment Page 3 NIT User Manual d CAUTION The PV inverter will become hot during operation please don t touch the heat sink or peripheral surface during or shortly after operation Risk of damage due to improper modifications Never modify or manipulate the inverter or other components of the system Page 4 ur A User Manual 2 2 Explanations of Symbols on Inverter Symbol A lt jm Description Dangerous electrical voltage This device is directly connected to public grid thus all work to the inverter shall only be carried out by qualified personnel DANGER to life due to high electrical voltage There might be residual currents in inverter because of large capacitors Wait 10 MINUTES before you remove the front lid NOTICE danger This device directly connected with electricity generators and public grid A Danger of hot surface The components inside the inverter will release a log of heat during operation DO NOT touch aluminum housing during operating An error
14. ol inverter is equipped with integrated RCD Residual Current Protective Device and RCM Residual Current Operated Monitor The current sensor will detect the volume of the leakage current and compare it with the pre set value if the leakage current exceeds the permitted range the RCD will disconnect the inverter from the AC load 2 Assembly Instructions 1 Strip the cable with the length 0 276 inches 9 32 7mm and please be careful NOT to nick conductors e Cable fb inches 52 mm 2 Screw off and separate each component of AC connector as follows a D 1 Page 19 NIT User Manual 3 Pass the cable through each component from left to the right as follows 4 Use a screw driver and loose the three screws at the side of the straight plug Then insert the stripped N L and PE cable accordingly to the corresponding position and fully tighten the screws 5 Aim the terminals on the straight plug to the holes of the grommet and then compress them together SS PR N d L N V oe e E E KE 6 Finally connect the straight plug to the AC terminal on inverter Pay attention to the polarity of the terminals to avoid wrong connecting 6 4 DC Side Connection DANGER DANGER to life due to potential fire or electricity shock NEVER connect or disconnect the connectors under load NOTICE DC Switch Optional may be integrated or external to Inverter and it can be used to conn
15. s in the following information table reference to 7 4 for further information Set Language Several languages are provided for users reference to 7 3 for further information 7 3 Set Language The Omnik inverter provides several languages for users to use At the entry of Set Language press the key for approx 5 seconds you can enter the language selection menu Choose the language which you need with the function key and keep this state without any operation When it returns to the main menu automatically the setting has been saved Page 27 BNI User Manual 7 4 State Information Tae ee mes O F W Updating Update About the further information for each fault please reference to chapter 9 TROUBLESHOOTING Page 28 ur A User Manual 8 RECYCLING AND DISPOSAL To comply with European Directive 2002 96 EC on waste Electrical and Electronic Equipment and its implementation as national law electrical equipment that has reached the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer required must be returned to your dealer or you must find an approved collection and recycling facility in your area Ignoring this EU Directive may have severe affects on the environment and your health A WARNING IS This device SHALL NOT be disposed of in residential waste Page 29 NIT User Manual 9 TROUBLESHOOTING LCD d
16. s weather conditions e High MPP tracking accuracy ensure the minimum power loses during converting e Complete set of protection methods Page 7 NIT User Manual Also following protection methods are integrated in Omnik inverter e Internal overvoltage e DC insulation monitoring e Ground fault protection e Grid monitoring e Ground fault current monitoring e DC current monitoring e Integrated DC switch Optional 3 3 Datasheet Max PV generator power Pov W 1750 2300 Max DC voltage Vmaxipc V 500 MPPT DC voltage range Vmppt V 120 450 Turn off DC Voltage Vminoc V 120 Max DC current lmaxoc A 18 Nominal DC current N DC A 14 16 5 Number of DC connection 1 DC connection Amphenol H4 Number of MPP trackers 1 Turn on power Pmin oc W 10 SS E E o eee Max AC Power Pmaxac V 1650 2200 Nominal AC power Prac W 1500 2000 Max AC current Lusstac A 9 0 12 0 Nominal AC current IN Ac A 6 5 8 5 Power connection Single phase Single phase According to VDE 0126 1 1 RD1663 ENEL2010 C10 11 G83 1 AS4777 According to VDE 0126 1 1 RD1663 ENEL2010 C10 11 G83 1 AS4777 Grid voltage range Grid frequency range Power factor 0 99 gt 30 of Full Load Harmonic distortion THD at nominal output lt 2 AC Connector Plug in connector Own consumption in operation Pownacy W 30 Power consumption at night Prigac W 0 Power consumption at standby Pstaac W Max Efficiency at 360VDC 97 4
17. tainless solid hanger and secured lock cylinder NOTICE For further maintenance and possible repair please keep the key of the padlock in a safe place After the inverter is hang up on the wall install the lock bracket on the aluminium radiator at the Lower Right Corner of the inverter as the picture showed below make sure the round hole of the lock bracket aim at the hole of the inverter after that lock up the device The lock bracket Page 17 ur A User Manual 6 ELECTRICAL CONNECTION 6 1 Safety DANGER DANGER to life due to potential fire or electricity shock With the inverter powered comply with all prevailing national regulations on accidents prevention This inverter will be directly connected with HIGH VOLTAGE power generation device the installation must be performed by qualified personnel only in compliance with national and local standards and regulations NOTICE Electrical connections shall be carried out in accordance with the applicable regulations such as conductor sections fuses PE connection 6 2 Overview of Connection Area Page 18 NIT User Manual Tone Datos Plug connectors for DC input BL RS232 RS485 interface C Terminal for grid connection AC output 6 3 AC Side Connection A DANGER DANGER to life due to potential fire or electricity shock NEVER connect or disconnect the connectors under load 1 Integrated RCD and RCM The Omniks
18. ten the life of the inverter 5 3 Safety Clearance Observe the following minimum clearances to walls other devices or objects to guarantee sufficient heat dissipation and enough space for pulling the electronic solar switch handle Owl Page 14 ur A User Manual Direction Minimum Clearance Above 30 cm 5 4 Mounting Procedure 1 Mark 4 positions of the drill holes on the wall according to the paper installation position scale packed in the carton box 25441 4 012 oe oe eo TFOZE 2 First according to the marks drill 4 holes in the wall Then place four expansion tubes in the holes using a rubber hammer Next wring 4 screws into the expansion tubes U V d d Page 15 unik User Manual 3 First check the 4 holes in the backside of the inverter Then lift the inverter carefully align the 4 holes in the inverter and the 4 screws in the wall and finally attach the inverter to the screws slightly 4 Please carefully check the accessories and original carton to make sure every necessary part is used and nothing is missing during installation 5 5 Safety lock To prevent possible theft activity Omnik gives you an extra guard for your property It is possible to lock the inverter to the rear panel with a padlock Page 16 NT User Manual Recommended padlock dimension 12 20 mm S