Home
SERVICE MANUAL
Contents
1. Lock Out and Tag Out procedures for electrical equipment 2 Before commencing pump service turn power supply off 3 Keep water away from electrical outlets and electrical devices 4 Electrical components must be installed by a qualified electrician to avoid risk of electrocution SERVICING THE VALVES Disassembly NOTE Pump requires one 1 valve kit to repair pump Valve kit includes discharge and inlet components i 2 a 4 Use a M8 allen to remove two 2 M10 socket head screws HSH from opposite outside corners of inlet discharge manifold IMDM As an aid in supporting the manifold replace these two 2 screws with two 2 M10 x 180 threaded studs PN 701268 Use a M8 allen wrench to remove remaining six 6 M10 HSH screws from IMDM Grasp IMDM and pull away from pump It may be necessary to use a rubber or plastic mallet to tap the backside of the IMDM to assist in removing from the pump NOTE The ball seat assemblies discharge valves and cylinder assemblies may remain in the IMDM or housing block 5 If ball seat assemblies remain in the IMDM use two flat tip screwdrivers on opposite sides and pry from IMDM Using a seal pick carefully remove sealing rings that may be on either side of the ball seat assemblies or in the IMDM 6 If cylinder assemblies remain in the housing block use two flat screwdrivers on opposite sides and pry from housing block 7 Remove the inlet valve spring and spri
2. making in field service convenient however there are a few custom tools special to certain models that do simplify the process This service manual is designed to assist you with the disassembly and reassembly of your pump The following guide will assist in determining the cause and remedy to various operating conditions You can also review our FAQ or SERVICE sections on our WEB SITE for more facts or contact Cat Pumps directly PROBLEM PROBABLE CAUSE SOLUTION Low pressure e Worn nozzle e Replace with proper size nozzle e Air leak in inlet plumbing e Tighten fittings and hoses Use PTFE liquid or tape e Pressure gauge inoperative or not registering e Check with new gauge Replace worn or damaged accurately gauge e Relief valve stuck partially plugged or improperly Clean adjust relief valve Replace worn seats valves adjusted and o rings e Inlet suction strainer filter clogged or improperly Clean filter Use adequate size filter Check more sized frequently e Abrasives in pumped liquid e Install proper filter e Leaky discharge hose e Replace discharge hose with proper rating for system e Inadequate liquid supply e Pressurize inlet e Severe cavitation e Check inlet conditions e Worn seals e Install new seal kit Increase frequency of service e Worn or dirty inlet discharge valves e Clean inlet discharge valves or install new valve kit Pulsation e Foreign material trapped in inlet discharge valves Clean inl
3. 2 Carefully slide the housing block over the ceramic plungers and place onto the pump guide pins Install the four 4 M10 HSH screws using an M8 allen wrench and torque to 18 5ft lbs or 222in lbs 24Nm 3 Inspect low pressure seals for wear and replace as necessary Slide low pressure seal onto each plunger with spring facing towards the IMDM Seat the low pressure seal into the housing block using seal installation tool 4 Place cylinder on a piece of hard wood or plastic with the larger diameter end up Install sealing ring with the radius facing up 5 Inspect the v packing assembly for wear and replace if necessary Insert v packing assembly into cylinder so one of the slots is aligned with the two water cooling holes in the cylinder Drive v packing assembly into the cylinder using a rubber or plastic mallet 6 Install rear o ring into each cylinder groove using a tacky grease to hold o ring in groove Install front o ring into each cylinder groove Install cylinders into housing block Apply a light coat of grease to each plunger and push the cylinder onto the plungers until the cylinders contact the housing block Rotate cylinders so the cooling water holes are in the 6 and 12 o clock position Align marks on cylinder and housing block as shown in figure 7 Install inlet valve spring onto each spring retainer and push it to the shoulder of the retainer Insert grooved end of the inlet valve into the spring Insert inlet valve assembl
4. pump under these conditions could result in personal injury and property damage 1 Ensure all fittings pipes and hoses are properly rated for the maximum pressure rating and flow of the pump Check all fittings and pipes for cracks or damaged threads Check all hoses for cuts wear leaks kinks or collapse before each use Ensure all connections are tight and secure Use PTFE thread tape or pipe thread sealant sparingly to reconnectplumbing Do not wrap tape beyond the last thread this will prevent tape from becoming lodged in the pump or accessories 6 Apply proper sealants to assure secure fit or easy disassembly when servicing B FROZEN LIQUID HAZARD Do not operate the pump with frozen liquid Operating the pump underthis condition could over pressurize and jettison the manifold from thecrankcase causing personal injury and property damage Mm BW NH 1 Store pump or pumping system in an environmentally controlled room protected from freezing temperatures 2 Follow procedures in TECH BULLETIN 083 to winterize pump C CLEANING PUMP HAZARD Do not use solvents that are flammable and toxic to clean or degreaseequipment Use of these solvents could result in personal injury andproperty damage 1 Follow safety instructions as found in MSDS or on packaging of each liquid 2 Clean equipment in a well ventilated area 3 Disposal of solvents to be in accordance with local state and federal regulations D OPERATING BEYON
5. D SPECIFICATIONS HAZARD Do not operate the pump outside the specifications of individual pumpdata sheet or service manual Operating the pump under these condi tions could result in personal injury and property damage 1 Do not operate the pump faster than the maximum recommended RPM 2 Do not operate the pump at pressures higher than the maximum recommended pressure 3 Do not operate the pump at temperatures higher than the maximum recommended temperatures 4 Do not use accessories that are not compatible or rated for the pump E LIFTING DEVICE HAZARD Do not lift pump with unsuitable lifting devices Use of unsuitable liftingdevices may cause pump to fall resulting in personal injury damage topump and or pump with drive base plate 1 Lifting eyes installed on the pump must be used only to lift the pump 2 Special lifting eyes should be installed on the base for lifting the pumping system i e base drive and accessories 3 If slings or chains are used for lifting they must be safely and securelyattached to properly balance the weight of the unit 4 Inspect slings and chains prior to use and replace worn and damagedslings and chains NOTICE A OILHAZARD Use only genuine CAT PUMPS custom blend premium grade petrole um based hydraulic oil Use of other oil may not provide proper lubrica tion of drive end components and may result in damage to thecrankcase of the pump 1 Cat Pumps custom blend oil is available worldwide in 21 oz
6. SERVICE MANUAL rar TD 1810 PLUNGER PUMP SERIES The Pumps with Nine Lives FLOW PRESSURE PUMP MOTOR TEMPERATURE SHAFTDIA OILCAP PUMP MODEL GPM L M PSI BAR RPM RPM Far Cent INCH MM Oz l 1810 3 0 11 4 10 000 690 1500 160 71 1 181 30 42 1 26 1810K 3 0 11 4 10 000 690 1500 1602 7 1c 1 181 30 42 1 26 IMPORTANT SAFETY INSTRUCTIONS It is the responsibility of the user to read and understand all instructions important safeguards and safety precautions before operating or servicing any pump Failure to do so may result in property damage personal injury or death General Safety Information and Symbols Pay special attention to the following signal words safety alert symbols and statements indicates a hazardous situation which if not avoided will result in death or serious injury indicates a hazardous situation which if not avoided could result in death or serious injury indicates a hazardous situation which if not avoided could result in minor or moderate injury or property damage indicates a hazardous situation which if not avoided could result in property damage A Indicates a potential personal injury hazard Obey all safety messages that follow this symbol to avoid possible injury or death SERVICING THE 1810 PLUNGER PUMP SERIES AWARNING Do not service pump or electrical equipment while energized Electricity can cause personal injury death or property damage 1 Adhere to
7. an and inspect the plungers for wear and replace if necessary Install barrier slingers on plunger rods 2 Apply a light coat of Loctite 242 to plunger rod threads and install plungers to plunger rods Using a 19mm wrench tighten plungers to approximately 8ft lbs or 96in lbs 10 4Nm 3 Install seal retainers to crankcase with drain slots orientated in the 6 and 12 o clock position 4 If the housing block and IMDM were removed as one assembly slide over plungers until it seats on crankcase guide pins Thread in four 4 M10 HSH screws by hand and tighten using a 8mm hex wrench Torque to 18 5ft lbs or 222in lbs 24Nm If the housing block and IMDM were removed individually follow assembly procedures for servicing the seals Loctite and 242 are registered trademarks of Henkel Corperation PREVENATIVE MAINTENANCE CHECK LIST If other than Cat Pumps special custom blend ISO 68 hydraulic oil is used change cycle should be every 300 hours Each system s maintenance cycle will be exclusive If system performance decreases check immediately If no wear at 1000 hours check again at 1500 hours and each 500 hours until wear is observed Valves typically require changing every other seal change Duty cycle temperature quality of pumped liquid and inlet feed conditions all effect the life of pump wear parts and service cycle Remember to service the regulator at each seal servicing and check all system accessories and connect
8. bottles cases or 5 gallon twin packs Use of other oils may void the warranty 2 Fill pump crankcase to specific capacity indicated on data sheet or service manual prior to startup B ROTATION OF PUMP HAZARD Do not rotate pump crankshaft in reverse direction Rotation of pump crankshaft in reverse direction may not provide proper lubrication andmay result in damage to the drive end components 1 Forward rotation is the top of the crankshaft turning towards the manifoldhead of the pump 2 Ensure oil is filled to the center red dot on sight gauge for forward rota tion 3 Ensure oil is filled to slightly above center red dot on sight gauge for reverse rotation C BELT TENSION HAZARD Do not operate pump with excessive belt tension Excessive belt ten sion may damage the pumps bearings or reduce horsepower 1 Rotate pump crankshaft before starting to ensure shaft and bearings are moving freely 2 Ensure pulleys are properly sized 3 Periodically replace belts to assure full horsepower transmission 4 Ensure center distance dimensions between pulleys is correct D BY PASS OPERATION HAZARD Do not operate the pump in by pass for extended lengths of time Operating the pump under this condition can quickly cause heat build up resulting in damage to the pump 1 Route by pass line to supply reservoir to dissipate heated by pass liquidinto a large reservoir of cool water to reduce excessive temperature build up 2 Route by pass line to inl
9. et discharge valves or install new valve kit Water leak e Under the manifold e Worn Hi Pressure or Lo Pressure Seals e Install new seal kit Increase frequency of service e Into the crankcase e Humid air condensing into water inside the e Install new oil cap protector Change oil every 3 crankcase months or 500 hours e Excessive wear to Lo Pressure and High Pressure e Install new seal kit Increase frequency of service seals Knocking noise e Inlet supply e Inadequate inlet liquid supply e Check liquid supply Increase line size or pressurize e Bearing e Broken or worn bearing e Replace bearing Oil leak e Crankcase oil seal e Worn crankcase oil seal e Replace crankcase oil seal e Crankshaft oil seal and o ring Worn crankshaft oil seal or o ring on bearing cover Remove bearing cover and replace o ring and or oil seal e Drain plug e Loose drain plug or worn drain plug o ring e Tighten drain plug or replace o ring e Bubble gauge e Loose bubble gauge or worn bubble gauge gasket Tighten bubble gauge or replace gasket e Bearing cover e Loose bearing cover or worn bearing cover o ring Tighten bearing cover or replace o ring e Filler cap e Loose filler cap or excessive oil in crankcase e Tighten filler cap Fill crankcase to specified capacity Pump runs extremely rough e Inlet conditions e Restricted inlet or air entering the inlet plumbing e Correct inlet size plumbing Check for air tight seal e Pump valve
10. et of pump using a thermo valve in the by passline or auto shut off assembly that will sense temperature rise and either by pass or shut down system before damage occurs E DRY OPERATION HAZARD Do not operate the pump without water or liquid Operating pump underthese conditions could result in damage to the pump 1 Open all valves on inlet side of pump before starting operation to pre vent starving the pump 2 Do not exceed inlet suction pressure limit specified in pump Data Sheet 3 Ensure inlet feed exceeds the maximum flow being delivered by thepump 4 Ensure all fittings pipes and hoses are properly sized for the pump to avoid restricted flow 5 Review and implement all other recommendations appropriate for your system from the Inlet Condition Check List DIAGNOSIS AND MAINTENANCE One of the most important steps in a high pressure system is to establish a regular maintenance program This will vary slightly with each system and is determined by various elements such as the duty cycle the liquid being pumped the actual specifications vs rated specifications of the pump the ambient conditions the inlet conditions and the accessories in the system A careful review of the necessary inlet conditions and protection devices required before the system is installed will eliminate many potential problems Cat Pumps are very easy pumps to service and require far less frequent service than most pumps Typically only common tools are required
11. ews into the housing block alternately until the IMDM is firmly against the cylinders Remove two 2 support studs and insert the remaining screws by hand Tighten the screws in an X pattern starting in the center and then move to the outside screws Torque to 40ft lbs or 480 in lbs 54 Nm in the sequence as shown below TORQUE SEQUENCE SERVICING THE SEALS Disassembly NOTE To service the seals it is necessary to remove the IMDM discharge valves inlet valves and cylinders Follow steps 1 to 6 under SERVICING THE VALVES Disassembly 1 Remove the inlet valves springs and spring retainers from each cylinder 2 Using a socket that fits inside the cylinder drive the v packing assembly out of each cylinder 3 Remove sealing rings and o rings from each cylinder 4 Use a M8 allen wrench to loosen four 4 M10 HSH screws from the housing block NOTICE Exercise extreme caution when removing housing block The weight of the housing block or any twisting action can damage the ceramic plungers 5 Grasp and support the housing block Remove four 4 M10 HSH screws and then remove the housing block from the crankcase by sliding housing block over the plungers 6 Remove seal retainers from crankcase 7 Using a flat screwdriver carefully remove the Lo pressure seals from each seal chamber of housing block Reassembly 1 Position seal retainers so the drain slots are in the 6 and 12 o clock position
12. ions before resuming operation GENERAL SAFTEY INFORMATION AND SYMBOLS A DANGER A FLAMMABLE OR EXPLOSIVE LIQUID HAZARD Do not operate pump with flammable or explosive liquids unless extraordinary safety precautions are observed Leaks of flammable or explosive liquids if exposed to elevated temperatures static electricity sparks or otherhazards will result in flame or possible explosion causing serious personal injury death or property damage 1 Before operating pump with flammable or explosive liquids ensure proper maintenance has been performed 2 Do not operate pump with flammable or explosive liquids if leaks are detected 3 Only pump flammable or explosive liquids that are compatible with pumpcomponent materials 4 Do not operate pump with flammable or explosive liquids without safeguardsor safety systems to detect leaks elevated temperatures spark preventionor any other hazards defined by the NFPAsystems Do not remove Flammable Liquids Product Suitability Hang Tag to assureproper safety 6 Follow ATEX guidelines for potentially explosive atmospheres Z AWARNING A ELECTRICAL SHOCK HAZARD Do not service pump or electrical equipment while energized Electricity can cause personal injury death or property damage 1 Adhere to Lock Out and Tag Out procedures for electrical equipment 2 Before commencing pump service turn power supply off 3 Keep water away from electrical outlets and elec
13. l injury or property damage 3 Do not check for leaks with hand Use a piece of cardboard to check for leaks 4 Review cleaning procedures to minimize heavy back blasting 5 Wear adequate safety equipment and clothing when operating high pressure sprayer Never use high pressure spray with bare feet or exposed skin and always wear safety glasses E PUMPING LIQUIDS HAZARD Do not operate pump with hot water chemicals or other hazardous liquids unless extraordinary safety precautions are observed Pumping hot water chemicals or other hazardous liquids can expose personnel to serious injury 1 Provide guards or shields around equipment to protect personnel 2 Wear mask goggles or eye protection while operating high pressure equipment 3 Obtain a material safety data sheet MSDS and take appropriate safetymeasures for the liquid being handled F OVER PRESSURIZATION HAZARD Do not operate high pressure pumping system unless extraordinary safety precautions are observed A high pressure pumping system can deadhead or over pressurize causing serious personal injury and property damage 1 All high pressure systems require a primary pressure regulating device i e regulator or unloader and a secondary pressure safety reliefdevice i e pop off valve safety valve rupture disc to assure proper pressure setting and overpressure protection 2 All high pressure systems require a pressure gauge to monitor pressuresettings and avoid overpress
14. ng retainer from each cylinder Reassembly 1 Install rear o ring into each cylinder groove using a tacky grease to hold o ring in groove Install front o ring into each cylinder groove 2 Apply alight coat of grease to the plungers and slide cylinders over the plungers until the cylinders contact the housing block Rotate cylinders so the cooling water holes are in the 6 and 12 o clock position 3 Examine inlet valves springs and spring retainers for wear and replace as needed 4 Install springs onto spring retainers and push it to the shoulder of the spring retainers 5 Insert grooved end of the inlet valves into springs 6 Install completed inlet valve assemblies into each cylinder with inlet valve facing out 7 Install sealing rings into cylinders with the radius facing out 8 Examine ball assembly seat inlet valve side and balls for wear and replace if needed as a complete assembly NOTE Ball assembly seat comes complete with seat ball and pin 9 10 11 12 Install sealing rings into IMDM with the radius facing up Install ball assembly seats into the IMDM The ball assembly seat should be installed so the inlet side with the nine small holes is facing up Apply antiseize lubricate to threads of the eight 8 M10 HSH screws Install two of them diagonally into the center holes of the IMDM Slide IMDM over support studs and press IMDM up to the cylinder o rings Using a M8 allen wrench thread the two 2 scr
15. s e Stuck inlet discharge valves e Clean out foreign material or install new valve kit e Pump seals e Leaking Hi Pressure or Lo Pressure seals e Install new seal kit Increase frequency of service Premature seal failure e Scored plunger e Replace plunger e Over pressure to inlet manifold e Reduce inlet pressure per specifications e Abrasive material in the liquid being pumped e Install proper filtration at pump inlet and clean regularly e Excessive pressure and or temperature of pumped e Check pressure and inlet liquid temperature liquid Running pump dry e DO NOT RUN PUMP WITHOUT LIQUID e Starving pump of adequate liquid e Increase hose one size larger than inlet port size e Eroded manifold e Replace manifold Check liquid compatibility CAT PUMPS l of 1681 94TH LANE N E MINNEAPOLIS MN 55449 4324 Y 4 PHONE 763 780 5440 FAX 763 780 2958 I e mail techsupport catpumps com The Pumps with Nine Lives www catpumps com For International Inquiries go to www catpumps com and navigate to the Contact Us link PN 31403 Rev A 12032
16. trical devices 4 Electrical components must be installed by a qualified electrician toavoid risk of electrocution B ROTATING PARTS HAZARD Do not service pump while energized Moving rotating or reciprocating parts can crush and cut causing personal injury death or property damage VI 1 Adhere to Lock Out and Tag Out procedures for electrical equipment 2 Before commencing pump service turn power supply off turn water supply off squeeze trigger on gun to relieve system pressure 3 For mobile equipment be sure engines and hydraulics are turned offand secured to avoid accidental start 4 Do not operate with safety guards removed 5 Always use safety guards on all belt drives couplings and shafts C HOT SURFACE HAZARD Do not touch pump accessories or drive system while operating and until cool down is complete Touching hot surface areas of the pump accessories or drive system can cause severe burns or personal injury D SKIN PUNCTURE HAZARD Do not allow spray to contact any part of the body or animals Pumped liquids under high pressure can pierce skin and underlying tissue or can deflect debris leading to serious personal injury or death 1 Relieve all line pressure in the inlet line to the pump and discharge linefrom the pump before performing any maintenance on the pump 2 When high pressure gun is not in use set safety trigger lock safetylatch to avoid accidental high pressure operation and persona
17. ure of equipment or personal harm 3 Install primary pressure relief device on the discharge side of the pump 4 Install secondary pressure relief device between the primary device andpump 5 Install pressure gauge onto the discharge manifold or in the discharge line near the manifold 6 Open all valves on discharge side of plumbing before operation G OXYGEN HAZARD Do not charge Prrrrr O Lators Pulsation Dampeners with oxygen Oxygen may cause an explosion causing personal injury death or property damage 1 Use nitrogen only when charging pulsation dampeners DO NOT USE OXYGEN 2 Use proper charging tools to charge pulsation dampeners 3 Charge pulsation dampener within specifications stated on data sheet to assure proper pulsation dampening and prevent failure of bladder H FALL HAZARD Do not operate pressure washer while standing on slippery or unstable surface unless extraordinary safety precautions are observed Pressure washing may create slippery surface on which a person may slip and fall causing personal injury or death 1 Wear suitable footwear to maintain a good grip on wet surfaces 2 Do not stand on ladders or scaffolding 3 Do not over reach or stand on unstable supports 4 Keep good footing and balance and hold gun with both hands to control kick back A CAUTION A IMPROPER USE OF FITTINGS HAZARD Do not operate the pump with improperly connected sized worn or loose fittings pipes or hoses Operating the
18. y into each cylinder 8 Install sealing ring into each cylinder with the radius facing out 9 Install sealing rings into IMDM with the radius facing up Install the ball assembly seats into the IMDM The ball assembly seats should be installed so the inlet side with the nine small holes are facing up 10 Apply anti galling grease to the eight 8 M10 HSH screws Install two of them diagonally into the center holes of the IMDM Install the IMDM up to the cylinder o rings Using an 8mm hex wrench thread the two screws into the housing block alternately until the IMDM is firmly against the cylinders Insert the remaining screws by hand Tighten the screws in an X pattern starting in the center and then move to the outside screws Torque in steps to a final torque of 40ft lbs or 480in lbs 52Nm SERVICING THE PLUNGERS Disassembly 1 Servicing the plungers can be done by removing the IMDM and housing block complete head together as one assembly NOTE If valves and or seals are also being serviced at this time follow the procedures for SERVICING THE VALVES and SERVICING THE SEALS for disassembly process 2 Remove four 4 M10 HSH screws from the pump crankcase Grasp complete head assembly and carefully side assembly over the plungers and away from crankcase 3 Using a 19mm wrench remove plungers from plunger rods Remove barrier slingers on plunger rods 4 Remove seal retainers from crankcase Reassembly 1 Cle
Download Pdf Manuals
Related Search
Related Contents
EJC 212 / 214 / 216 / 220 INSTALLATION INSTRUCTIONS ELECTRICAL GAUGES/KITS GM03-16bit Library and Sample Code User`s Manual Aston SEN980-TR-CH-40-8-L Installation Guide Débitmètre INLINE pour une mesure de débit en continu Hardware User`s manual Sun Moon Technology Corp. Processo di installazione PDF:1.7MB Philips AZD102/12 docking speaker instructivo - MABE Venezuela Copyright © All rights reserved.