1. F H i HEATOR SRE 704 injection OPERATING NG anah IONS SE GEBRUIKSAANWIJZING Dear Sir Madam Congratulations with your purchase of a portable domestic heater You have purchased a quality product which will serve you for many years to come This of course provided you use the heater correctly Please read these Directions for Use first to ensure maximum lifetime for your heater Your heater comes with a 24 month manufacturer s warranty on all defects in materials or workmanship We wish you a warm and comfortable time with your heater Yours sincerely PVG International b v Customer Service Department 1 READ THE DIRECTIONS FOR USE FIRST 2 IN CASE OF ANY DOUBT CONTACT YOUR DEALER 3 BEFORE YOU START READING FOLD OUT THE LAST PAGE gt gt GENERAL DIRECTIONS FOR USE Below you will find the main steps to be taken for using your heater For more details please refer to the MANUAL pages 35 f 4 Remove all packaging materials refer to Section A Fig A 2 Fill the removable tank refer to Section B Fig 3 insert the plug into the wall socket ignite the heater using the key refer to Section D Bj it required change the temperature using the adjustment keys refer to Section 6 switch off the heater by pressing the key gt P P P P P P POP POP P OP P MAIN COMPONENT Front plate Grid Base p
2. 7 We expressly dismiss all other claims for damages including consequential damages Any repairs or replacements of components within the term of warranty will not result in an extension of the term of warranty TF The warranty shall no longer apply when the heater has been modified non original parts have been used or when it is repaired by third parties The warranty shall not apply to parts that are subject to normal wear such as the burner mat and the manual fuel pump 5 The warranty shall only apply when you present the original dated proof of purchase provided no changes have been made to it E The warranty shall not apply to damages caused by actions not in compliance with the Directions for Use neglect and the use of an incorrect type of fuel or fuel past its use by date The use of incorrect fuel can even be dangerous 7 Transportation costs and the risks involved during the transportation of the heater or heater components shall always be at the expense of the purchaser In order to avoid unnecessary costs we recommend that you always read the Directions for Use carefully first In case they offer no solution please take the heater to your dealer for repair Highly inflammable substances may induce uncontroffable burning causing flames to break out Should this happen never try to move the heater but always switch off the heater immediately n case of eme
3. has started This will take a short while Once the heater is burning the button will remain tit yellow The information display will show two numbers The light next to them indicates that these numbers refer to the temperatures Fig F The actual room temperature is indicated below ROOM while the temperature setting is indicated below SET The latter can be changed with the adjustment keys refer to Section E Prior to igniting the heater always check for sufficient fuel in the removable tank SETTING THE REQUIRED TEMPERATURE The temperature setting can only be adjusted when the heater is burning Use the adjustment keys to adjust the temperature First press either of the two keys to switch on the function the TEMP light next to the information display will start blinking Next adjust the temperature using the key on the right min to set the temperature to a higher setting and the key on the left Whour to lower the temperature Press once to increase the value one step After approximately 10 seconds the light will stop blinking and the setting will be locked Fig F The available temperature settings range from 6 C minimum to 28 C maximum When the heater has been unplugged or after a power failure the temperature will reset to the factory setting of 20 C F USING THE TIMER The timer allows you to switch on the heater automatically at a preset time In order to switch on the timer the correct time mu
4. starting from section A and as specified RU NT N TRANSPORTATION Toke the following measures to avoid fuel leakage during the transportation of the heater Let the heater coo down Remove the removable tank from the heater and remove the fuel filter refer to Section L Fig L Some drops may leak from the filter keep a cloth at hand Store the fuel filter and the removable tank outside the heater 3 Place the transportation cap into the position of the fuel filter Fig M Press it tight Always move the heater in an upright position LD specirications transportation cap Ignition electrical Dimensions mm width 374 Fuel paraffin including base plate depth 280 Capacity kW max 20 height 430 Capacity KW min 08 Accessories manual fuel pump Suitable space m 30 120 transportation cap Fuel consumption WAN 033 Mains 220V 230V Fuel consumption gfhry 250 ACISO Hz Burning time per tank hr 12 8 Electrical consumption igniter 320 W Capacity removable tank litres 4 0 continuous 32 W Weight ka 95 Fuse rating 250V SA Atenaxieum setting f Specified values are indicative P WARRANTY PROVISIONS Your heater comes with a 24 month warranty starting on the date of purchase Within this period all defects in material or workmanship will be repaired without any charge The following provisions shall apply regarding this warranty
5. C DEACTIVATION This heater is fitted with a safety system that ensures that it switches off automatically after 48 hours continuous operation The following will then appear in the display 48 Hr If desired you can switch the heater on again by pressing the button D see chapter D set room AUTOMATIC CLEANING MODE When the heater has been burning continuously for two hours at its highest setting the burner will automatically start an autoclean procedure The display will show the autocleaningcode 21 25 running back to 1 02 The procedure takes 5 minutes during which the heater will burn at its lowest setting while the burner autodeans When the burner is clean again the heater will automatically switch back to the highest setting again cHILDPROOF Lock The childproof lock can be used to prevent children accidentally changing the heater settings When the heater is burning and the childproof lock is on the heater can only be switched off Other functions are blocked then If the heater has already been switched off the childproof lock also prevents accidental ignition of the heater Activate the childproof lock by pressing the appropriate key B and holding it down H When the KEV LOCK light lights up the for more than 3 seconds The KEY LOCK indicator light will light up Fig H espes Ree has been indicating that the childproof lock has been activated Switch off the childproof lock activat by pressing the ke
6. ater needs hardly any maintenance It is however important that you dco Rn an clean the air filter and the vent filter with a vacuum cleaner and the grid that you m kjerke with a damp cloth both on a weekly basis Remove the air filter occasionally Fig K and clean it with soapy water Prior to reinstallation make sure that the air filter cap has fully been dried Regularly inspect the fuel filter as well 1 Remove the removable tank from the heater and remove the fuel filter Fig L Some drops may leak from the filter keep a cloth at hand fuel filter 2 Remove the dirt by tapping the fuel filter upside down against a hard surface Never clean it with water 3 Reinstall the fuel filter into the heater We recommend that you remove dust and stains from time to time with a damp doth because otherwise these may cause stains that are hard to remove M STORAGE END OF THE HEATING SEASON At the end of the heating season you must store the heater in a dust free place if possible in its original packaging Unused fuel cannot be used in the next heating season We therefore recommend that you burn up all fuel if there is still some fuel left do not throw it away but dispose of it in accordance with the local regulations for the disposal of domestic chemical waste Always start the new heating season with fresh fuel When you start re using the heater follow the instructions again
7. e tank Clean off any spilled fuel S Check whether the fuel cap is straight and tightened properly Reinstall the removable tank in the heater cap down Close the lid SETTING THE CLOCK it is only possible to set the correct time when the heater is connected to the mains and not burning Use the adjustment keys to set the time First press either of the two keys to switch on the function the CLOCK light and the information display will start blinking Next set the hours using the key on the left Whour and the minutes using the key on the right min Press once to increase the value by one step When you hold down the key the value will continue going up until you release the key again After approximately 10 seconds the light will stop blinking and the setting will be locked 5 minutes after switching off the heater the information on the display will disappear and the heater will automatically switch into the stand by position wien the heaters hai been unplugged or After power failure tha time needs to be set again si u Meu aa IGNITING THE HEATER When used for the first time a new heater may give out a smell for a short while You should therefore provide extra ventilation Always ignite the heater with the button Never use matches or a cigarette lighter Just press the button to ignite the heater The button will start blinking indicating that the ignition procedure
8. l Ind San Jos de Valderas II Comunidad La Alameda C Aurora Boreal 19 28918 LEGANES Madrid tel 349161131 13 434916127304 pvgspainGzibro com OB er Lister Gases Bridge Street Holloway Bank Wednesbury West Midlands WS10 OAW Tel 44 121 506 1818 Fax 44 121 505 1744 email gases lister co uk PVG italy SRL Via Niccol Copernico 5 50051 CASTELFIORENTINO Fl tel 39 571 628500 fax 439571628504 email pugitaly zibro com Sunwind Gylling A S Lexaveien 17 P O Box 64 1351 RUD tel 47 67 17 1370 fax 47 67 17 13 80 email pygdenmark zibro com i E PVG International b v P O Box 96 5340 AB OSS 31 412 694694 31 412 622893 email pvgalGzibro com PVG Polska Sp z o o Kolonia Promna 58 26 803 PROMNA tel 4848615 1633 fac 4848 615 16 33 email pvopolandezibro com Markt Portugal Lda Recta da Granja do Marqu s ALGUEIRAO 2725 MEM MARTINS tek 35121 922 8530 fak 4351219228536 email pvgint zibro com Printed in Japan 6846001921
9. late e 8 6 Lid for removable tank Operation panel Handle Removabte tank oo 9608 Fuet gauge removable tank Air filter Vent filter Thermostat Plug cord information display key Chitdproof lock 9 o 4 e o Adjustment keys time and temperature Timer Indicator lights Only the use of the correct fuel will ensure safe efficient and comfortable use of your heater This transportation cap is packed separately in the box Only this cap ensures trouble free transportation of the heater after use Store it well WHAT YOU NEED TO KNOW IN ADVANCE ALWAYS MAKE SURE THAT THERE IS SUFFICIENT VENTILATION For each model the minimum size of space is specified in which you can use the heater safely without additional ventilation refer to Section O If a particular room is smaller than the specified space always put a window or door slightly ajar 4 2 5 cm We also recommend doing this in highly insulated or draught free rooms and or at altitudes above 1 500 metres However if there is insufficient ventilation i e oxygen the heater will automatically switch off Do not use your heater in cellars or other underground areas THE RIGHT FUEL Only use Class C1 paraffin fuel in accordance with BS2869 Part 2 or equivalent Your heater has been designed for use with high quality water free pure paraffin oil such as Zibro Plus Only fuels of this kind will ensu
10. mer the next time This not only switches off the heater but it also activates the timer function You can change the required time with the adjustment keys refer to Section f H THE INFORMATION DISPLAY The information display not only serves as an indicator of the set time and temperature Sections C E and f it also indicates any malfunctioning of the heater The code on the information display tells you what is the matter fn case of any CODE INFORMATION WHAT TO DO gaenang the E Temperature within the heater too high Cool down and re ignite information display wi g tell you what is the F 8 Power interrupted Re ignite the heater matter Er t Faulty thermostat Contact your dealer e KEENE EEE Pes Fauity burner thermistor Contact your dealer 2 Starting problems Contact your dealer E 5 Tipping over protection Re ignite the heater E amp Poor burning Contact your dealer E 3 Room temperature if necessary above 28 C re ignite the heater 8 Defective booster Contact your dealer 9 Air filter dirty or Clean filter Fuel pump dirty Contact your dealer 48 Hr The heater has been in operation continuously for a period of 48 hours and has turned itself off automatically Switch the heater back on Out of fuel Refill removable tank reng muss Too little ventilation Ventilate better Vor Always contact your dealer for any malfunctioning not listed above AUTOMATI
11. re clean and proper burning Lower quality fuel may result increased possibility of malfunctioning incomplete burning reduced heater lifetime smoke and or smells deposits on the grid or mantle Using the right fuel is therefore essential for safe efficient and comfortable use of your heater vvvvv Always refer to your local dealer for the right fuel for your heater INSTALLING THE HEATER B Carefully remove your heater from the box and check the contents In addition to the heater you also need to have gt a manual fuel pump gt a transportation cap these directions for use Keep the box and the packaging materials Fig A for storage and or transportation z Open the lid of the removable tank and remove the piece of cardboard f Do Fill the removable tank as indicated in Section 8 F The floor should be firm and completely level Reposition the heater when it is not level Do not try to correct the situation by placing books or other goods under the heater Please refer to the separate instructions in the carton box for fixing of the heater Insert the plug into the wall socket 220 230 Volts AC 50 Hz and set the correct time using the adjustment keys refer to Section C Your heater is now ready for use FILLING FUEL not fill the removable tank in the living room b
12. rgency you may use a fice extinguisher but only a type B extinguisher a carbon dioxide or powder extinguisher 10 TIPS FOR SAFE USE Make sure that children ate always awar heater Vert s Do not move the heater when itis burning or still hot service the heat r when it Is burning or still hot Position the front of the h ater at a distance of mini from walls curtains and furniture Do hot use th heater in dusty pi i hot have optimum burnini S nding of a bath heater In theiimmedi Swimmingpool gt Rev 8 02 DISTRIBUTED IN EUROPE BY PVG INTERNATIONAL BV PVG France SARL A Rue Jean Sib lius B P 185 76410 SOTTEVILLE SOUS LE VAL tel 33232960747 fax 433232960777 email pvgfrance zibro com PVG Austria VertriebsgmbH Salaberg 49 3350 HAAG tel 43 7434 44867 fax 43 7434 44868 email pvgaustria zibro com ET PVG Belgium NV SA Industrielaan 55 2900 SCHOTEN tel 3233263939 fax 43233262639 email pvgbelgium6zibro com PVG Schweiz AG Genuastrasse 15 4142 MUNCHENSTEIN teli 44161337 26 51 fax 4161337 26 78 email pvgint amp zibro com PVG Deutschland GmbH BeiersdorfstraBe 4 46446 EMMERICH tel 49282176713 fax 31412 648385 email pygint zibro com PVG Scandinavia A S Niels Bohrsvej 10 6100 HADERSLEV 45 73 53 02 02 fax 45 7353 02 04 email pvgdenmarkezibro com PVG Espafia S A Po
13. st have been set refer to Section C and the heater should be off Follow the procedure below 3 Press the amp button and then the TIMER key immediately after that The TIMER light and the information display will start blinking 2 Use the adjustment keys to set the time at which the heater must ignite Use the key on the left Whour to set the hours and the key on the right A min to set the minutes interval of 5 minutes lempe ook ox 3 After approximately 10 seconds the information display will show CLOCK again and the TIMER indicator light will light up indicating that the timer function has been activated Fig G timer hour min G The TIMER indicator 4 The timer will ensure that the room will have been heated to approximately the required temperature at the set time light indicates that the timer function has been switched on When you want to switch off the heater and ignite it gain with the timer ll you Have to do is press the TIMER key refer to section G Press the button once to clear the timer setting G SWITCHING OFF THE HEATER There are two ways to switch off the heater T Press the button The information display will show the CLOCK signal Within approximately one minute the flame will have extinguished Z Press the TIMER key when you want to switch off the heater and ignite it again with the ti
14. ut in a more suitable place there can always be some spillage Follow the procedure below Make sure that the heater is switched off Open the lid and lift the removable tank out of the heater Fig B Note Some drops may leak from the tank Put down the removable tank cap pointing upwards and screw off the fuel cap Take the manual fuel pump and insert the smooth most rigid tube into the jerrycan Make sure that it is in a higher position than the removable tank Insert the ribbed hose into the opening of the removable tank Lock the switch button on top of the pump turn clockwise Squeeze the pump a few times until fuel starts flowing into the removable tank As soon as this happens there is no need to press any longer e E When the CLOCK indicator ight stops blinking the setting has been locked to the indicated value set room T PT LEE FT A F The required temperature on the left the measured temperature on the right E Check the removable tank fuel gauge while filling the tank Fig Stop filling by loosening the switch button on top of the pump turn anti clock wise once the gauge indicates that the tank is full Never overfill the tank especially not when the fuel is very cold fuel expands when it heats up 7 Let the remaining fuel in the pump flow back into the jerrycan and carefully remove the pump Carefully screw the fuel cap back on th
15. y and holding it down for more than 3 seconds once again J THE FUEL INDICATOR LIGHT When the FUEL indicator light lights up there is enough fuel left for another 10 minutes of heater use The count down of the remaining heating time can be seen in the information display Fig D Every two minutes an alarm signal is sounded warning you to refili the removable tank If you do not react the heater EEE a will extinguish by itself The heater will also sound a warning signal when it switches off The FUEL indicator light will blink while four lines are blinking in the fU ove information display You can stop this by pressing the button D once Once the heater has used up all its fuel and is extinguished it will take some time after the refill before the heater is completely ready for use again set room ot When the FUEL indicator light is lit the MEN formation display wis K THE VENT INDICATOR LIGHT show the number of When the VENT indicator light starts blinking this is a sign that the room is not e we x vented sufficiently Fig J If you do not provide additional ventilation the heater the tani will switch off automatically after some time If the indicator light continues blinking after extra ventilation please contact your dealer EET L MAINTENANCE switch off the heater and let it cool down before you start any maintenance work Also disconnect the plug from the mains 4 A blinking VENT Your he