Home
        ISTRUZIONI PER L'USO OPERATING INSTRUCTIONS
         Contents
1.             ISTRUZIONI PER L USO  OPERATING INSTRUCTIONS  MODE D EMPLOI  BEDIENUNGSANLEITUNG  GBRUIKSAANWIJZING  BRUGERVEJLEDNING  INSTRUCCIONES DE USO  INSTRUCOES DE UTILIZAGAO  OAHTIEX AEITOYPTIAZ    os ae    Cod  252 100 10    MOBILE AND FIXED GAS SALAMANDERS C      0051    MOD  SG GN 1 1  SGF GN 1 1 GB IE     CAT  l2H3        INDEX    Warnings  Compliance with EEC directives for gas appliances  Installation diagrams    Technical data table     Gas salamanders  Characteristics of gas    Data plate    Instructions for qualified installer  Appliance installation  Legal standards  technical regulations and guidelines  Smoke discharge for type    A    appliances  Check for gas leaks    Maintenance  Converting for use with a different type of gas     gas salamander  Changing spare parts    User instructions  Lighting the pilot  Lighting and turning off main burner  Complete shutdown of salamander    Maintenance  cleaning and care  Maintenance  Cleaning and care  What to do if the appliance is going to be out of use for long periods of  time     Exploded functional parts table  Exploded functional parts table for gas salamanders    THIS APPLIANCE HAS BEEN MADE FOR COOKING FOOD AND MUST ONLY BE  USED BY PROFESSIONALLY SKILLED PERSONNEL IN THE WAY DESCRIBED IN  THIS INSTRUCTION MANUAL     1  WARNINGS       Read this handbook through carefully as it provides important information for safe  installation  use and maintenance        Keep this handbook in a safe place for future refere
2.  GAS SALAMANDER SG GN 1 1 AND SGF 1 1    The appliance is tested and set for working with gas according to the characteristics table  attached near the appliance s gas inlet   In order for it to function with a different type of gas  proceed as follows     The conversion must be carried out by qualified personnel    The nozzles for LPG are supplied with the appliance in a nylon bag    Changing the burner nozzle  fig  1    remove the cover  1  from the cooking top of the cabinet  2  the burner  3  will thus    remain completely visible  Open the air regulating bush  24  of the burner  3   completely and change the nozzle  27   Put everything back in place  place the burner  air regulating bush  24  at the distance specified   A   in the TECHNICAL DATA table  according to the type of gas   Fig 3     Changing the pilot nozzle  19    remove the panel  1   from the cooking top of the cabinet  2   unscrew the pilot    connection pipe  and replace the nozzle  making sure you insert the nozzle and the  pilot connection pipe in the nozzle holder at the same time     Check that there are no gas leaks by using a soapy water solution     Regulating the minimum flame   remove the cock knob  8   use a screwdriver to turn the cock  6  adjustment screw  7     until you get the minimum flame required  Make sure that the supply pressures are  those given in the instruction handbook and on the data plate     Supply pressure   it must be as specified on the appliance   s data plate and in the in
3. INTENANCE  CLEANING AND CARE    Always disconnect the appliance from the gas supply before starting on any  maintenance work     9 1 MAINTENANCE    There is very little maintenance to do thanks to the correct way the appliances have been  made    However  we do advise having the systems checked by qualified personnel at least twice a  year    Control cocks  they should be checked and greased by a gualified technician every 6 12  months     9 2 CLEANING AND CARE    To ensure proper operation  clean the cooking grill frequently  as well as the grill  supports and the fat collection tray  Clean the stainless steel surfaces with a damp  cloth or with soap and water  if you use detergents  make sure they contain no  CHLORATES or ABRASIVES  then wash with water and dry thoroughly     9 2 1 What to do if the appliance is going to be out of use for long periods of time     First of all  disconnect the gas supply       clean thoroughly  following the instructions     incase of failures  turn the appliance off and notify the assistance service     10 1 EXPLODED FUNCTIONAL PARTS TABLES          Mod  SG GN 1 1  Mod  SGF GN 1 1                 F     gt  S  lt        O Se  a 18     W             St   Z   Ps5 U  or      S        19                               a        CHIUSO PILOTA MAX MIN  FERME  VEILLEUSE MAXIMUM MINIMUM  GESCHLOSSEM  ZUNDFLAMME LAAG HOOG    CLOSED PILOT  DICHT WAAKULAM       
4. ck in place     Radiant panels  4   remove the cover  1  of the cooking top of the cabinet  2   loosen the panel  fastening screws  remove and replace the panels by turning them around the burners  3  then  put everything back in place     N B     After any replacement or repair  check for proper operation of parts that   were replaced and adjust them    Check for leaks from the gas pipe fittings with a soapy water solution     never use a bare  flame     USER INSTRUCTIONS  8 1 PILOT IGNITION     GAS SALAMANDER    Push the knob  8  and turn it counter clockwise round to the pilot position M  spark  symbol   Simultaneously press the piezoeleciric lighter knob and button and the pilot  burner will light  Keep the knob pressed for 10 to 15 seconds and then let it go  Check  ignition of the pilot located underneath the cooking top of the cabinet  If it hasn t  repeat the  operation     8 2 TURNING THE MAIN BURNER ON AND OFF    From the pilot position 4    turn the knob again counter clockwise round to the maximum  position    big symbol   I he burner lights automatically  By the turning the knob again  counter clockwise round to the    position  small symbol   the burner will be on minimum   To turn the burner off  turn the knob clockwise round to the JK position  only the pilot  burner stays alight     8 3 COMPLETE SHUTDOWN OF SALAMANDER    To turn the salamander off completely  press the knob in the JK position and turn it  clockwise round to the position      closed      9  MA
5. nce        Only professionally skilled personnel must install the appliance and  if required  convert  it to receive a different type of gas        Only call one of the manufacturers authorised technical assistance centres for repairs  and demand original spare parts     Failure to observe the above could undermine the safety of the appliance     2  COMPLIANCE WITH EEC DIRECTIVES     GAS APPLIANCES    THIS APPLIANCE HAS OBTAINED THE    CE    APPROVAL CERTIFICATE AS IT  SATISFIES ALL THE TESTS CARRYING OUT IN ACCORDANCE WITH STANDARD    ESSENTIAL REQUIREMENTS ANNEX   EEC DIRECTIVE 90 396 MD 26 06 1990     4  TECHNICAL DATA TABLE     GAS SALAMANDERS             TOTAL GAS DIAMETER OF NOZZLES IN   o NEGE CONSUMPTION HUNDREDTHS OF A MILLIMETRE  MODEL X POWER LPG iu LPG NATURAL GAS   G30   G31    o G30     G31 G20   No  x kW kg h m3 h 30 mbar 37mbar 20 mbar  SG GN 1 1  ETA 0 544 135L 205L  BY PASS 115 ADJUSTABLE  PILOT 19 27  PRIMARY AIR POSITION A mm   20 15   THESE VALUES ARE          APPROXIMATE   ALWAYS  MAKE SURE THE FLAME IS  REGULAR        4 1 GAS CHARACTERISTICS    The data relative to power and consumption refer to the following types of gas     TYPE OF GAS NET HEAT VALUE PRESSURE SUPPLY   NHV   mbar mm water  G20  natural gas  CH4 9 45 kW ms h 20 200  G30  butane  C4Hto 12 68 kW kg 30 300  G31  propane  C3H8 12 87 kW kg 37 370  G25  G20L     DE  8 12 kW m   h 20 200  G25  aardgas NL  8 12 kW m   h 25 250    When installing the appliances  the gas supply pressures must be 
6. ppliances  see the Technical Data Tables  and are not for  connecting to a natural discharge duct for combustion products    These appliances must discharge through specific extractors  or similar devices   connected to a properly working flue or discharged directly outside    lf this is not possible  an air suction device can be used connected directly to the outside   with a capacity that must be no less than that required  see Table 1  plus the quantity of  fresh air that is necessary for the well being of the workers     6 4 CHECKING FOR GAS LEAKS    Once installed  check there are no gas leaks on pipe joints using a soapy water solution   You will know if there are leaks by the foamy bubbles that form  Never use open flames to  check for leaks    When the appliance is ready to use  check that there are no gas leaks  by checking on the  gauge  if used  for a period of 30 minutes   that there is no passage or consumption of  gas     Z     MAINTENANCE    There is very little maintenance thanks to the correct way the appliances have been made   However  we do advise having the systems checked by gualified personnel at least twice a  year     N B   the manufacturer declines all responsibility for direct or indirect damage    7 1    caused by incorrect installation  bad maintenance  tampering  improper use  and failure to comply with the accident prevention norms regarding the  prevention of fire and safety for gas systems     CONVERSION FOR USE WITH A DIFFERENT TYPE OF GAS   
7. struction handbook     see the Technical Data table   Check the supply pressure by inserting a rubber pipe   with a water gauge or similar  in the pressure tap  10  welded on the gas shaft  9  by  removing the screw  11   After it has been checked  tighten the screw  If the supply  pressure is different than that specified  find the cause and correct it     7 2 CHANGING SPARE PARTS    Safety cock  6    remove the cover  1  from the cooking top of the cabinet  2   loosen the nut  5  for    connection to the supply shaft  9  and to the burner supply duct  12   unscrew the  thermocouple  16  and the pilot ducting  21  from the cock and replace the cock     Thermocouple  16    remove the panel from the cooking top of the cabinet  2   unscrew the thermocouple  16     from the cock  6  and from the pilot support  18  and then change it     Ignition plug  20    remove the lid  1  form the cooking top of the cabinet  2   loosen the plug fastening nut  front the pilot support 18   Remove the plug and change it     Piezoelectric lighter  13    remove the lid  1  from the cooking top of the cabinet  2   remove the plug connecting    cable  14   remove the fastening nut of the piezoelectric lighter and make the replacement     Pilot burner  18     remove the lid  1  from the cooking top of the cabinet  2   loosen the pilot fastening nut   19  and the thermocouple  16   remove the ignition plug connecting nut  remove the pilot  securing screws and change the pilot    Now put everything ba
8. those given above in  order to have maximum burner efficiency     Pressures mbar  1 millibar  lt  1 mbar  lt  10 mm  water column millimetres   Power  1 kW   860 kcal   3 6 MJ   3412 BTU    6  INSTRUCTIONS FOR THE GUALIFIED INSTALLER  6 1  APPLIANCE INSTALLATION    e Remove the appliance from its packaging and position it  always  under an aspiration  hood     e Always use rigid galvanised steel or copper pipes for connecting the appliance     e Ifthe appliance is wall mounted  in contact with flammable material  place a layer of  heat resistant insulating material between the appliance and the wall or leave a space  of 200 mm between the appliance and the wall     e The appliance gas system and the characteristics of the room in which the appliance is  installed must comply with current laws     6 2 LAWS  TECHNICAL REGULATIONS AND GUIDELINES   e Standard UNI CIG 8723  Ministerial circular no  68 dated 25 11 69 and variations   e Accident prevention laws    e Always install a cut off cock between each appliance and the gas pipe     e Check that aeration in the room is sufficient when the appliance is working  considering  that the necessary quantity of air for combustion is 2 m  h of air for each kW of installed  power     6 3 DISCHARGE OF FUMES FOR TYPE    A    APPLIANCES    The appliances must be installed on premises that are suitable for the discharge of the  combustion products and must comply with the installation rules  Our appliances are  considered type    A    gas a
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Mélia - Free  Haier AS072AZBDA User's Manual  L401A3 取扱説明書  Photonen & Audiotherapiegerät ELTR-X 8020 - Live-Photonic  01 OK.qxd  e-Appraisal System Appraisee and Appraiser User Guide    Copyright © All rights reserved. 
   Failed to retrieve file