Home

User's Manual - Spencer Italia S.r.l.

image

Contents

1. as follows Place all female elements on the male Velcro elements Fold all straps towards the central strap Fold all straps according to the central strap Fold the small holding strap around the package to fix all straps together 4 2 PREPARATION On receipt of the product Remove the packaging and display the material so that all components are visible Check that all the components pieces on the accompanying list are present The appliance must be checked before every use so as to reveal any working abnormalities and or damage caused by transport and or storage Before and after every use perform a check as described check if the device shows any cuts holes or damages on the surface check the integrity of all components of the device make sure the straps fold in an adequate way make sure the connecting parts connect well make sure the regulation of the device is easy If everything is conform the device may be considered ready for use 4 3 FUNCTIONING 1 2 3 4 D o Place the connection at the top of the Z straps immediately under the neck Unroll the Z Straps towards the feet maintaining the central position of the central strap Distribute the fixation straps according to the fixation points on the stretcher and on the corpse shoulders pelvis knees feet Fix first the thorax strap by closing simultaneously both straps in order to avoid rolling movements of the corpse and render the immobilisation per
2. operator s gloves incomplete closure due to spring lock systems etc Designed and adapted to the needs of versatility and adaptability to connection points dimensions of any type of corpse 3 2 MAIN COMPONENTS i Immobilisation strap in nylon and polyethylene 2 Velcro male part 3 Velcro female part 3 3 MODELS ZCO0101A Z Straps 3 4 TECHNICAL DATA Thickness 1 5 mm Length 1620 mm Width system 900 mm Width belt 49 mm Weight 490 g Material nylon and polypropylene Colour black Floatation yes Type of fixation central strap with Velcro Number of fixation straps 10 Use with spine boards with at least 5 handles on each side Manufacturing system heat cut sewing raftering 3 5 ENVIRONMENTAL CONDITIONS Functioning temperature from 20 to 60 C Storage temperature from 20 to 60 C Relative humidity from 5 to 85 4 OPERATING INSTRUCTIONS 4 1 TRANSPORT AND STORAGE oe Re ae Before transporting the appliance make sure that it is correctly packaged ensuring also that there are no risks of shocks bumps or falls during the transport itself Keep the original packaging for use in case of any further transport Damage to the appliance caused during transport and handling is not cove red by the guarantee Repairs or replacement of the damaged parts are the responsibility of the client The appliance must be stored in a dry place free from humidity For correct storage of the device proceed
3. Z Straps Immobilization system for recovery board Guarantee of Quality system for the production and the final control of the products certified by the notifying body TUV Italia S r l INDEX General Information page 2 Operating Instructions page 3 Warnings page 2 Maintenance and Cleaning page 4 Description of Product page 2 Accessories and Spare parts page 4 Spencer ltalia S r l Strada Cavi 7 43044 Collecchio Parma ITALY tel 0039 0521 541111 fax 0039 0521 541222 e mail info spencer it SP 09 102 IU REV 0 13 10 09 www spencer it Thank you for choosing a Spencer product 1 GENERAL INFORMATION 1 1 AIM AND CONTENTS The aim of this manual is to supply all the information necessary so that the client will not only attain adequate use of the appliance he will also be capable of using the instrument in the most autonomous and secure way possible This includes information regarding technical aspects functioning maintenance spare parts and safety 1 2 CONSERVATION OF THE INSTRUCTION MANUAL The instruction and maintenance manual must be kept with the product inside the specially provided container and above all away from any substances or liquids which could compromise perfect legibility 1 3 SYMBOLS USED SYMBOL po MEANING General or specific warning See instructions for use Lot number Product code HIBS 1 4 SERVICING REQUESTS For any information regarding the use maintenance and i
4. fectly symmetric Fix the pelvis strap at front superior iliac spine level Fix the knee strap preferably just above Fix the terminal strap around the feet in order to limit rotational loads on the limbs and up and down movement of the corpse against the Z straps 4 4 TROUBLESHOOTING PROBLEM CAUSE REMEDY Too long straps Check the fixation straps Extreme corpse mobility Straps out of position Make sure the straps are positioned correctly 5 MAINTENANCE AND CLEANING 5 1 CLEANING The Z Straps system may be cleaned with delicate cleaning products or water and soap in case of presence of blood first oxidise then wash with water 5 2 MAINTENANCE 5 2 1 Precautionary Maintenance The device does not require programmed servicing 5 2 2 Special servicing Only the manufacturer or centres with written authorisation are authorised to complete any special servicing operations For any operations that are not carried out directly by the manufacturer but by an authorised centre we have to underline that a report regar ding all operations carried out must be requested This will permit both Spencer Italia S r l and the end user to keep a log book regarding the operations carried out on the device The device if used as indicated in the following instruction manual has an average life span of 5 years The life span can be expanded only following a general revision of the product that must be carried out by the manufacturer or by a centre aut
5. horised by the manufacturer 6 ACCESSORIES AND SPARE PARTS There are no accessories or replacement parts for this item Warning The information contained in this document could be modified without any warning and is not to be intended as a commitment on behalf of Spencer Italia S r l Spencer products are exported to many countries and the same identical regulations are not always valid For this reason there could be differences between the description here described and the product actually delivered Spencer continually strives to reach the perfection of all items sold We therefore hope you will understand if we reserve the right at any time to modify the shape equipment lay out or technical aspects that are herein described Copyright Spencer Italia S r l All rights reserved No part of this document can be photocopied reproduced or translated into another language without the written approval of Spencer ltalia S r l
6. nstallation please contact the Spencer Customer Care Service on tel 0039 0521 541111 fax 0039 0521 541222 e mail info spencer it or write to Spencer Italia S r l Strada Cavi 7 43044 Collecchio Parma ITALY 1 5 DEMOLITION Follow the current regulations 1 6 LABELLING The serial number as indicated below can be found on each appliance and must not be removed or covered In order to facilitate assistance please indicate or communicate the number LOT on the label 2 WARNINGS Ss 2 1 GENERAL WARNINGS Before carrying out any kind of operation on the appliance the operator must carefully read the enclosed instructions paying particular attention to the correct safety precautions and to the procedures to be followed for installation and for correct use In the case of any doubts as to the correct interpretation of the instructions please contact Spencer Italia S r l for any necessary clarifications Regularly check the appliance In the case of any abnormalities or damage to the appliance which could jeopardize the functioning and the safety the appliance must be immedia tely removed from service Do not alter or modify in any way the appliance any such interference could cause malfunctions and injury to the operator The appliance must not in any way be tampered with In such cases all responsibility will be denied for any malfunctions or injuries caused by the appliance itself Those who modify or have modified prepare or have prepa
7. red products in such a way that they no longer serve the purpose for which they were inten ded or no longer supply the intended service must satisfy the valid conditions for the introduction onto the market Ensure that all the necessary precautions are taken in order to avoid the hazards that can arise as the result of contact with blood or body fluids Handle with care 2 2 SPECIFIC WARNINGS The product must be used by trained personnel only If any failure or incorrect functioning of the device is detected it must be immediately substituted with a similar item so that the procedures are gua ranteed without any interruption The device must not be exposed or get in contact with sources of heat or inflammable substances Use the straps only as described in this user s manual Always check the integrity of the straps before every use Substitute damaged or worn out straps immediately Select accurately the fixation points of the straps The Z Straps system must be applied by at least two adequately trained operators 2 3 CONTRAINDICATIONS AND SIDE EFFECTS The use of this device if used as described in this manual does not present any contraindications or collateral effects 3 DESCRIPTION OF PRODUCT 3 1 INTENDED USE The Z Straps system represents an efficient method for the fixation of the corpse on immobilization supports Recommended for all operations which require quick application without the risks related to metal buckles damage to the