CONTROL PANEL INSTALLATION MANUAL

image

Contents

1. WORKING CYCLE CHOICE By setting the dip 2 of SW in ON the automatic function is activated The door soon after an opening impulse will carry out the complete cycle open stop close By setting the dip 2 of SW in the OFF position the step by step function will be activated That is by giving one two three four impulses the door will carry out first the opening cycle when the second impulse is given the door will stop when the third one is given the door will start closing and when the fourth si given the door will open again ON SW OFF 25 01 2005 21 FINAL STROKE ACTIVATED By setting the dip 3 in the ON position the final stroke is activated it gives full force to the motor for 2 seconds at the end of the closing cycle If the dip 3 of SW is on the OFF position the final stroke remains deactivated SW ON OFF 29101 2005 22 PRE BLINKING FUNCTION the ON position of dip 4 of SW activates the pre blinking fucntion the blinker is activated 3 seconds before the motor start When the dip 4 of SW is in the OFF position the pre blinking function is deactivated the blinker gets activated at the same time of the motor ON SW OFF 25 01 2005 23 OPENING CLOSING TIME ADJUSTMENT The working time can be adjusted through the trimmer WORK between 3 and 60 seconds The working time has to be set up so that the motor remains powered up for a two three seconds seconds after the end of
2. the opening or closing cycle of the door 25 01 2005 24 AUTOMATIC CLOSING TIME ADJUSTMENT BREAK TIME Make sure that the dip 2 of SW is on the ON position Adjust the trimmer BREAK to modify the automatic closing time break time It is possible to change it from a minimum of 3 to a maximum of 75 seconds set the dip 2 of SW on the OFF position to exclude the automatic closing POWER ADJUSTMENT Use the trimmer POWER Adjust the force according to the UNI 8616 regulations 25 01 2005 25 ANTI CRUSHING MODULE OPTIONAL e An anti crushing module is available optionally to be installed on the control unit This device works both in Opening and closing and in case of any crush of the door against an obstacle it reserves the movement for two seconds and then stops The unit indicates the module operation is indicated with a quick flashing of led D9 green e The door will start the opening only when the obstacle is removed and the start command is pressed For the function of the anti crushing module it is necessary to install the closing and opening limit switches 25 01 2005 26 RADIO CODECS FRUURANINIING Operations of inserting a new code into the memory and cancelling the whole list of codes can be carried out on the receiver This last one is made see picture on the low left from the union of items A e B Programming 1 Power up the receiver correctly see below picture RECEIVER is made of it
3. with a 16A monophase switch and fuses Make sure that the ground wire terminal 1 is properly connected to the ground dispenser of the system It is necessary to respect the phase and neutral polarity in the 230V a c power supply line terminal 3 phase terminal 2 neutral The minimum section required for the power circuits motors and blinker outputs is 1 5 mma Always use separated connection for auxiliary and control inputs power ciurcuits in order to avoid interferences or damages caused by unduced tensions do not use only one multipolar wire In case of lines longer than 50 mt it is advisable to dismatch the control circuits with some relays in the control board If the n c inputs limitswitches photocells stop button are not used they have to be connected to the common terminal 15 through jumpers After installing all the security and electrical devices buttons photocells blinkers etc and having done all the electrical connections power up the control unit and check the following Remember that the inputs which are not used have to be jumpered If led DL1 red is not on check that the 230V a c power tension arrives to the terminal 2 and 3 also control the fuses integrity and if necessary replace them with others of the same capacity After starting the motors make sure that they can be stopped with a force no higher than 150N about 15 Kg according to the UNI 8612 regulations If necessary adjust the force through the P
4. CONTROL PANEL INSTALLATION MANUAL BASC 2002 e The PCB Basc 2002 is a electronic control board used for overhead swing garage motors with or without clutch It 1s strong and reliable Its reduced dimensions allow the insertion of the unit inside the motor The introduction in IP55 containers is not provided e It is arranged for the use of a timer to be connected to the START input for programmed opening and closing Free from interference and protected against atmospheric and electrostatic discharges e The control board Basc 2002 has succeeded all tests concerning the electromagnetic emissions and the immunity to the interference as provided by the European rules in force e It conforms to the directives EMC 89 336 CEE 92 31 CEE BT 73 23 CEE and 93 68 CEE 25 01 2005 14 SUGGESTIONS ON THE CONTROL PANEL INSTALLATION The installation must be done by specialized technicians in compliance with the local national and European regulations in force UNI 8612 as well as to the instructions quoted on this manual The installer must verify the type of system and if necessary connect security devices differential and magnetothermic switches which comply with the current regulations The manufacturer declines any responsibility for damages to people or things caused by wrong installations improper and unreasonale usages tampering as well as by non observance of the current regulations Protect the control board with a 6A automatic switch or
5. OWER trimmer 25 01 2005 15 TIT i tee ey nike a Oo Ti eee T Po Then Bm Ee 10 11 12 13 t4 1516 17 18 19 1 i g 8 i fase E i b l E i T j b iD Uw cy Fr neutro o i r I a DFE i o Tos 9oeo6e en 29101 2005 SENS Electrical chart BASC 2002 FOTO NC wiring and position ON OFF FAP N C of the SW FCH N C LUCE CORT 230 Vac COMUNE 40 12 13 14 15 16 17 18 19 TRASM RICEV NS EGG 230 Vac 7 8 9 ALIMENTAZ FOTOCELL Luce cortesia Antischiacciamen o 29101 2005 17 2230 Vac 25 01 2005 TECHNICAL FEATURES uu TOD A O Arrangedto theuse Max Start Power in op ening cy cle fixed 18 DIP SETTING e WARNING all the adjustments must be carried out with the door in close position After the dip switch programming it is necessary to turn off the control board first and then turn it on again in order to activate the new adjustments 25 01 2005 19 START POWER By setting the dip 1 of SW in ON see picture below the start power is activated as the two motors start it lasts 2 seconds By setting the dip 1 of SW in OFF the start power is deactivated ON OFF 25 01 2005 20
6. RE COULD BE SOME EXCLUSIONS Total cancellation codes 1 Press and keep pressed the MEM CLEAR button till the LED red light starts flashing 2 The confirmation is given as soon as the LED stops flashing 25 01 2005 RADIO CODES PROGRAMMING TECHNICAL FEATURES Power supply 12 24 Vac dc Average Work Rest 25 mA 45 mA consumption Number of codes that can be 312 FF ih Signals Ol JRedled SSS O 25 01 2005 30
7. em A inserted in item B THE RECEIVER is then inserted in the control panel C 25 01 2005 2 RADIO CODES PROGRAMMING gt To program a code on the first channel press shortly the button LEARN the red LED lights on ndicating that programming is in progress Carry ut a transmission by pressing any button of the emote control The code is inserted into the memory At the end the LED returns to the non ighting state 3 To program a code on the second channel keep pushed the LEARN button the red light LED switches off and switches on Release the button and the LED light switches on again Do a ransmission activating the transmitter Microkey R 114401 Keypad Remote control that you want to nemorize The code has been learned At the end he LED goes back to non lighting phase 29101 2005 Red light LED Button MEM CLEAR Button LEARN RADIO CODES PROGRAMMING 4 Memorise all the transmitters repeating operations 2 or 3 Red light LED o After the LEARN button pressure exit from the programming comes about automatically if no transmitter button is pressed within 15 seconds 6 The codes remain in the memory even if the receiver s power supply is cut Button MEM CLEAR Button LEARN rR IF MORE THAN ONE ACTIVATOR IS MEMORIZED Microkey R 114401 keypad Remote control etc THE PROGRAMMING MUST ALWAYS START WITH THE REMOTE CONTROL OTHERWISE THE