Contents
1. 9 5 2 Set up left and right limiting positions for Speed Dome and start the Left amp right Scam 11 5 3 Set up activate and close Home Position function of the Speed Dome 12 5 4 Set up and run the Tour Group of Speed DOmMe 13 V Installation and Connection 18 I Description of Performance 1 Brief introduction The controlling keyboard can be used to control matching terminal devices directly such as high constant speed dome cameras decoders etc The electric port between the controlling keyboard and the receiving terminal is EIA RS 485 which enables the keyboard to control as many as 128 speed dome cameras or other terminals within a maximum communication range of 1 5 Km 2 Technical Data Power supply DC12V 500mA Power adaptor provided AC220V 10 50 60HZ switch to DC12V 500mA Communication mode for RS 485 for the connection with mainframe connection RS 485 bus mode for the connection with controlling devices Baud rate of communication 1200 2400 4800 9600 19200 BIT S Distance of communication 1500M 0 5MM twisted pair Dimension 202 L x 168 W x 48 H mm Ambient Temperature 100 600 Relative Humidity lt 90 RH Il Description of Main Functions and Features 1 Photoelectric insulated RS485 controlling mode is adopted for the output of t
2. the LCD returns to the state of inputting next preset position number 1 lAdd position Position No 1 Now press F2 OFF key the tour group set up in Step O will be stored in the speed dome camera LCD will return to the operation of Step O Repeat the operations of Steps LJ J O to set up tour groups for all speed dome cameras then repeatedly press EXIT key twice to exit the setup 5 4 2 Run the Tour Group of the Speed Dome Camera Enter the menu for running tour group Repeatedly press FUN until LCD displays 5 Run Group Press ACK to enter the running of tour group Enter tour group number When entering the running of tour group LCD will display 5 0 Input Group No 1 Enter tour group number from the numeral key section ranging 1 4 Run tour group 17 After entering the tour group number press F2 OFF to run the tour group LCD displaying Run Group Group No 1 Return from the submenu of Run Tour Group Press EXIT key V Installation and Connection 18 Attention Please read the Manual carefully before installation and connection for any incorrect cable connection may cause permanent damages to the units Make sure power is switched off before connection and all communication cables are shielded twisted pair All communication cables should avoid high voltage cables or other jamming sources Figure for Keyboard D
3. VAS User Manual VNS KB103 Keyboard for Speed Dome Description of Performance 1 1 Brief Introduction 2 2 Technical Data 2 ll Description of Main Functions and Features 3 Ill Description of Keyboard Panel 4 1 Front Panel 4 2 Back Panel 6 IV The Operation of the Keyboard 7 1 Select Camera Decoder AddressS 7 2 The control of Pan tilt and Camera lenS 7 3 Set up preview and delete Preset Positions 8 4 Enter Exit Camera Menu 8 5 Operations through the Menu of the Keyboard 9 5 1 Set up the Baudrate and Protocol for the keyboard
4. VR and Camera Connection DVR Keyboard R548 5 antput port R548 5inpat port Power socket RS435 R5483 RS435 RS485 port Speed Dome Camera 19
5. When protocols and Baud rates for all the channels are set up please press EXIT key to exit the setup ll 5 2 Set up Left right Limiting positions start and stop Left amp right scan 5 2 1 Set up Left Right Limiting positions for Speed Dome Camera Enter left right limiting positions setup Repeatedly press FUN key until the LCD displays 3 Limits Setup Press ACK to enter the setup of left right limiting positions Left limiting position setup When entering the setup of left right limiting positions the LCD will display 3 0 Limits Setup Limit Left Please press PRESET or PREVIEW key until the cursor shows Left then use the joystick to move the speed dome camera to the desired left limiting position Press F2 OFF key to store the present left limiting position into the dome camera LCD displaying Left Limit Set OK Right limiting position setup When entering the setup of left right limiting positions press PRESET or PREVIEW key until the cursor shows Right then use the joystick to move the speed dome camera to the desired right limiting position Press F2 OFF key to store the present right limiting position into the speed dome LCD displaying EE Right Limit Set OK Exit left right limiting positions setup Press EXIT key to exit left right limiting positions setup 5 2 2 Start and stop Left amp
6. d the information of the operation The controlling joystick controls the speed dome to move upwards downwards left and right with variable speed and is used for manually locating Instructions CAM camera channel selection confirmation PRESET preset position setup PREVIEW preset position previewing 0 9 numeral keys CLEAR clear key AUTO automatic left amp right scan ON OFF F1 ON Ancillary switch ON F2 OFF Ancillary switch OFF IRIS Iris wider IRIS Iris narrower ZOOM Zoom ratio higher ZOOM Zoom ratio lower FOCUS Focus farther FOCUS Focus nearer FUN Function key ACK Acknowledge key EXIT Exit key 2 Back Panel Figure S 485 output 485 input power BABA lt LlLl CE Sa Power supply outlet connecting external DC12V power Communication outlet RS 485 output outlet connects with the RS 485 outlet of the decoder RS 485 input outlet connects with the outlet of DVR mainframe or built in hard disk VCR IV Operation of the Keyboard 1 Select Camera Decoder Addresses On the keyboard press the number N then press CA M Display New N value will be displayed on the CAM section of the LCD displayer Remarks N speed dome camera number range 1 255 Function Select the address of the Speed Dome or Decoder that is de
7. etup the LCD will display 1 Please Input Camera No 888 Explanations The above information suggests the User enter the camera number for Baud rate and protocol setup The default camera number is 10 888 indicating that all the cameras have the same protocol and Baud rate If the User intends to set up different protocols and Baud rates the default 888 should be changed to corresponding camera number ranging 1 128 Protocol and Baud rate setup After setting up the camera number press ACK key to enter protocol and Baud rate setup LCD displaying Protocol PELCO_D Baud Rate 2400 Explanation The above information shows the present protocol and Baud rate Five kinds of protocols are optional for the User PELO D PELCO P PELCOD1 PELCOP1 and NEW Press PREVIEW or PRESET key to select desired protocol After setting up the protocol press F1 ON key to switch the cursor to the state of Baud rate setup Applicable Baud rates are 1200 2400 4800 9600 19200BPS Press PREVIEW or PRESET key to select desired Baud rate Store the present setup of protocols and Baud rates After setting up protocols and Baud rates press F2 OFF key to store the setup into the keyboard and the keyboard will display the state of entering new channel number Through Steps 0 D O different protocols and Baud rates can be set up for special channels
8. he keyboard which provides strong anti jamming and long distance transmission 2 The keyboard can control up to 128 Speed Domes or Decoders etc terminal devices The address of the Speed Domes or Decoders can be set within the range of 1 255 3 Variable speed operation can be applied to the built in Pan tilt of the Speed Dome through the keyboard 4 Lens zooming focus and iris can be manually controlled through the keyboard 5 Manually or automatically control can be applied to Soeed Dome through the keyboard 6 Joint control can be realized by using the DVR keyboard together with one DVR mainframe or embedded hard disk VCR 7 Preset positions can be set up and previewed in Speed Dome through the keyboard 8 Tour groups can be set up and run through the keyboard 9 Left and right limiting positions can be set up and Left amp right scan can be run through the keyboard 10 Home position can be set up activated and closed through the keyboard Ill Description of Keyboard Panel 1 Front Panel On the front panel of the DVR keyboard are variable speed controlling joystick keys and LED digital displayer The LED digital displayer shows the state of the system an
9. on store the present position as the N position 3 2 Preview Preset Position On the keyboard input Preset Position No N then press PREVIEW Display The DATA section of the LCD will display PREVIEW Remarks N preset position number range 1 255 Function Switch the camera to position number N 3 3 Delete Preset Position On the keyboard input Preset Position No N then press EXIT Display The DATA section of the LCD will display DELPRE Remarks N preset position number range 1 255 Function Delete the stored preset position number N 4 Enter Exit Camera Menu 4 1 Enter camera menu On the keyboard input the number 3 then press F1 ON Display The DATA section of the LCD will display MENUON 4 2 Exit camera menu On the keyboard input the number 3 then press F2 OFF Display The DATA section of the LCD will display MENUOFF 5 Setup through the menu of the Keyboard 5 1 Set up the Baudrate and Protocol for the Keyboard Different Baudrate and protocol can be set for different channel through the Keyboard When the keyboard switch dome camera decoder addresses it will output corresponding controlling instructions based on the setup protocols and Baud rates Enter Baud rate protocol setup Continually press FUN key until the LCD displays 1 Keyboard Setup Press ACK key to enter Baud rate protocol setup Enter desired camera number On entering keyboard s
10. right scan Start For Low speed Dome and Constant speed Dome cameras press the AUTO key on the keyboard the Speed Dome camera will automatically scan back and forth between the left and right limiting positions well for High speed Dome camera the left amp right scan is generally started by the method of previewing some certain preset position what preset position should be previewed to start the left amp right scan depends on the High speed Dome camera itself Stop For all kinds of Soeed Dome cameras any operation on the joystick of the keyboard can stop the Left amp right scan Well for Low speed and Constant speed Dome cameras the Left amp right scan can also be stopped by pressing AUTO key for one more time 5 3 Set up activate and close Home Position function of the Speed Dome 5 3 1 Set up the Home Position _ Enter home position setup Repeatedly press FUN key until LCD displays 4 Home Setup 213 Press ACK key to enter home position setup Set up Home Position When entering home position setup LCD will display 4 0 Home Setup Home current lie Use the joystick to move the dome camera to the desired home position and press F2 OFF key to store the present home position into the speed dome LCD displaying Exit home position setup Press EXIT key 5 3 2 Activate and close Home Position function 5 3 2 1 Activate Home Position function On the keyboard pre
11. sired to be controlled the Speed Dome or Decoder corresponding with the value N is to be under control 2 The control of Pan tilt and Camera lens 2 1 Lens zoom for close up image ZOOM 2 2 Lens zoom for panoramic image ZOOM 2 3 Lens focus farther FOCUS 2 4 Lens focus nearer FOCUS 2 5 Iris wider IRIS 2 6 Iris narrower IRIS 2 7 Automatic switch AUTO on off cyclical key 2 8 Brush on off Press numeral key 1 then press key F1 ON to switch on press numeral key 2 then press key F2 ON to switch off 2 9 Light on ff press numeral key 2 then press key F1 on to switch on press numeral key 2 then press key F2 on to switch off 2 10 The direction and speed of the pan tilt movement can be freely controlled through the variable speed controlling joystick The speed of pan tilt movement depends on the operating angle of the controlling joystick 8 changing the slope angle of the joystick will adjust the movement speed Display Related operation information will be displayed on the DATA section of the LCD 3 Set up preview and delete Preset Positions 3 1 Set up Preset Position Operate the joystick on the keyboard to move the camera to the position desired to be set as Preset Position input Preset Position No N then press PRESET Display The DATA section of the LCD will display PRESET Remarks N preset position number range 1 255 Functi
12. ss the number 4 then press F1 ON Display The DATA section of the LCD will display HOME ON 5 3 2 2 Close Home Position function On the keyboard press the number 4 then press F2 OFF Display The DATA section of the LCD will display HOME OFF 5 4 Set up and run the Tour Group of Speed Dome 5 4 1 Tour Group Setup Enter Tour Group Setup Press FUN key to enter keyboard menu making the LCD display 14 2 Speed Dome Group Setup Explanation The above information indicates the setup of tour group Press ACK key to acknowledge and the LCD will display 1 0 Speed Dome No 1 Group No 1 Explanation The above information suggests the User enter the speed dome camera address and tour group number Input the address of the Speed Dome Camera and set up the serial number of the Tour Group Operation procedure Enter speed dome camera address from the numeral key section 0 9 ranging 1 255 then press F1 ON key to switch the cursor to tour group setup and enter tour group number ranging 1 4 For example if the User intends to set up the second tour group of dome camera NO 3 first enter number 3 and press F1 ON key to switch the cursor to tour group setup and enter number 2 the LCD displaying 1 0 Speed Dome No 3 Group No 2 After setting up the dome camera address and tour group number press ACk key to enter the next se
13. tup Add Preset Position Number to the Tour Group 15 a Add Preset Position Number Following the above step O Input the address of the Speed Dome Camera and set up the serial number of the Tour Group press ACK key to enter the state of adding preset position number the LCD displaying 1 lAdd position Position No 1 Explanation The above information suggests the User enter preset position number Enter the preset position number from the numeral key section 0 9 ranging 1 128 then press ACK to acknowledge and enter the next step b Set up the parameters for the Preset Position Following the above step LCD displays 1 2Position XXX Time 3 Explanation The above information suggests the User set up the dwelling time of the preset position XXX is the preset position that was input in the previous step Enter dwelling time of the preset position from the numeral key section ranging 1 255 seconds then press ACK key to acknowledge and a preset position is successfully added to the tour group The LCD display returns to the state of preset position setup for further addition Please repeat the first and second steps to add all the preset positions required into the tour group Store the Tour Group set up in Step O in the Speed Dome Camera 16 After all preset positions are successfully added to the tour group as is shown in Step O the display on