Home
CISS Communication Library User Manual
Contents
1. processings The instrument is able to store big quantity of data and for this reason it isn t convenient receive all contents every time So it s possible to specify to RCCL library that it has to receive the data starting from specified date hour and arriving to last datum available in the instrument the latest datum For this reason use method ecm GetElaborations fromDT The object fromDT is type DateTime and includes the date hour of first required processing The method that instrument uses for data storage could start some processings shortly before the specified date but it always assures the sending of data processed from required date hour and the next data The manage of the data through the application has to take into consideration this possibility and for this reason filter the data received but not required At the end of communication the method linked to event BinDataReceivedEventHandler will be recalled and it will be possible to use the received data List lt ElabDataRow gt edrc List ElabDataRow e DataReceived The processings are included in one list of object ElabDataRow every object represent one processing event and includes one or more elaborated items For example if the instrument has been configured with two measures and every 10 minutes each measure produces statistic processings type Min Ave Max each object ElabDataRow will include 6 numeric values corresponding to one processing
2. C and they are read again only if needed and automatically At the end you have to connect to events of object ELogCommManager in order to manage the facilities in asynchronous way ecm DataReceivedEvent new CommHelper DataReceivedEventHandler ecm DataReceivedEvent ecm BinDataReceivedEvent new CommHelper BinDataReceivedEventHandler ecm BinDataReceivedEvent ecm CommSequenceTerminatedEvent new ELogCommManager CommSequenceTerminatedEventHandler ecm_CommSequenceTerminatedEve nt 4 4 Data reception Now everything is ready to start communication for example in order to receive the data from the instrument last values acquired or calculated by measures it s possible use method ecm GetCalcValues Method GetCalcvalues and all methods for request of data RCCL implemented is asynchronous i e its call finishes fast before the end of communication with the instrument In this way it s possible manage the interface of application without problems stops but it s necessary to limit the operations allowed to user before the end of communication for example avoid the call to other communication method because the library could have an exception type Protocol is busy At the end of communication there are two possibilities the communication has ended successfully or the communication has failed In first case it ll be possible use the received data in the
3. IA LSI LASTEM S r l Via Ex S P 161 Dosso n 9 20090 Settala Premenugo MI Italia Tiv Tel 39 02 95 41 41 WEB http www lsi lastem it CER Fax 39 02 95 77 05 94 CF P Iva VAT IT 04407090150 E iso 2001 2000 e mail info glsi lastem it REA 1009921 Reg Imprese 04407090150 RCCL CISS Communication Library User Manual Updating 15 9 2008 RCCL User manual D Nea E a on d Pd i fei MR Pod Poi d aded N R dota silenced tien d Ebr acu DL aaO 3 cci e 3 3 Example ONIN aac REMO PORTTITOR IY 4 UN elc cC TEE mm 5 21 Preparation of fest DIGIEOL e reat ar n ete a E tosta ea e Du un A dn io arias 5 4 2 Communication channel crnini a a 5 AA DU GER aa A tm 6 2E a a CNRC UEM SUR T 43 Durno conim ogo n 8 LA NU oi the Objet adana 9 RCCL User manual L introduction RCCL library is a software that allows the communication with LSI LASTEM instruments that are compatible with CISS proprietary protocol particularly with E Log V2 instruments and following releases The library can be used to process Windows applications that need to transfer the data produced by E Log acquirer and CISS compatible instruments Using library you can obtain this performance easily and fast Library has been developed in Microsoft NET Framework V3 0 and for this reason it can be used by compatible development systems 2 Product installation Executing proper i
4. Statistics 07 08 2008 19 21 05 PC clock 7 Soft update Actual Date Time C Auto Running Time Elaborated Values From 07 08 2008 19 21 05 Bytes In order to communicate with an E Log instrument use the application following these instructions it s better if inside development environment in order to understand its operation 1 2 3 4 5 Select the communication channel Communication Channel used for connection to the instrument there are three channels available set up the use parameters according to used channel Execute connection of communication channel pressing key Connect Ask the instrument for instantaneous values pressing key Get in the section Instantaneous Values check in the section Communication Statistics the steady data stream at the end of communication the list of instantaneous value should show all measures programmed in the instrument and corresponding last acquired or calculated value in this section it s possible communicate with the instrument automatically and continuously sticking box Auto Ask for registry information of the instrument pressing key Get in the section Instrument Registry Ask for statistic information about instrument s operation pressing key Get of the section Instrument Clock amp Statistics in this section it s possible communicate with the instrument automatically and continuously sticking box Auto furthermore pressing key Sync Clock it s possibl
5. e synchronize the clock inside the instrument with the same date hour displayed near the key the synchronization is made in soft way gradually but only for differences not more than one hour if it s been stuck box Soft update before enter the command at last 4 RCCL User manual stick box PC clock in order to obtain the automatic updating of text for hour selection according to date hour of PC s system 6 Press key Predicted size is in the section Elaborated Values in order to ask for evaluation of dimension of processed data which need to be transferred according to specified starting date hour so press key Get in the same section in order to ask for elaborated data at the end of communication the pertinent text box should include the received data 4 Fast Start Making reference to example application here below you can find the information for implementation of one program which is able to communicate with E Log instrument and download the acquired data in fast way you can find further details about library in proper documentation included in file RCCL chm The library has been developed with C7 language and the examples for its use will have same language The examples included in the documentation aren t a complete programming course at the opposite they need a quite well programming knowledge and ability in NET environment with language C 4 1 Preparation of test project Set up new application Windows Form in developmen
6. entHandler ecm_CommSequenceTerminatedEve nt ecm Dispose ccb ConnectedEvent new CommChannelBase ConnectedEventHandler ccb ConnectedEvent ccb Dispose
7. event of 10 minutes of which is also specified date hour sorted like configured in the instrument i e Misural Min Ave Max Misura2 Min Ave Max 4 5 During communication Some communications need lot of time to be concluded especially if they use slow communication channels In order to assure the user about the right operation of the application it s possible to supply the statistic of running communication in real time It can be reached through the object that includes the communication channel the property ecm CommChannelLayer Statistics includes useful information for this purpose and they can be easily show through application s user interface RCCL User manual 4 6 Disposing of the objects The objects that include the communication s channel and protocol can keep in use valued resources of the system i e the serial communication lines After their use we recommend to dispose them through available method Dispose Before the disposing of the object we recommend to disconnect previous connected events in order to avoid the reception because they could have been started by asynchronous facilities of the library ecm DataReceivedEvent new CommHelper DataReceivedEventHandler ecm DataReceivedEvent ecm BinDataReceivedEvent new CommHelper BinDataReceivedEventHandler ecm BinDataReceivedEvent ecm CommSequenceTerminatedEvent new ELogCommManager CommSequenceTerminatedEv
8. everal capacities that are acquired partly by hierarchy of classes from which it derivates and partly by methods it includes There are some available facilities that need to know for their correct operation the current configuration of parameters that manage the operation of the instrument setup of measures processings etc these information are required by functions for decoding of data acquired and elaborated by measures ELogCommManager is able to ask the instrument the configuration data independently and only if needed but this operation is very expensive in terms of time and data flow think about costs in case of use of telephone communication channels For this reason it s possible specify to ELogCommManager to use an 6 RCCL User manual management object of configuration s persistence which is able to utilize all information already received in a previous communication session and already stored in local system PC and it doesn t need to download them again from the instrument A standard implementation of persistence management object is already available in library RCCL it s available like class BasicConfigInfosPersister and an object like this type is sent to ELogCommManager through the statement ecm ConfigInfosPersister new BasicConfigInfosPersister The management of the object BasicConfigInfosPersister by means of ELogCommManager 1S totally clear because the configuration data are persistent in P
9. nstallation program Setup exe you can install the product Default installation is made in folder ProgramFiles LSI Lastem CISS Communication Library In this folder are set up following subfolders e bin it includes the library s files particularly o LSI RCCL dll it s main library s it s compatible with NET 3 0 o LSIModemHip dil it s a standard Microsoft COM library Common Object Model for the management of the modem through TAPI interface this library must be set correctly using the utility RegSvr32 or other equal system in order to can be used in user s application setup procedure supplied by LSI LASTEM made it automatically o Jnterop LSIMODEMHLPLib dll it s the library for inter operation between COM and NET using library LSIModem Hlp dll e doc it includes this document e src it includes the sources of example application e exe example application already filled and ready to use RCCL User manual 3 Example Application The library is supplied together with an example application that includes source code in CZ language and has been developed through Microsoft Visual Studio 2008 in NET 3 0 environment The application has following mask EB LSI LASTEM RCCL Test Program Communication Channel Communication Statistics SeralPot 1 Speed 9600 Bytes In Out O Phone Modem Phone Number Msg In Out Er TCP Instantaneous Values Instrument Registry Serial C Auto Instrument Clock amp
10. p the remaining parameters in this case the use of one serial nr 1 with bit rate 9600 bps cp ccp CommChannelType CommChannelTypes Serial cp ccp ComPort 1 cp ccp Speed 9600 Now it s possible use following instruction for set up of communication channel ccb CommChannelBase Factory cp The object ccb is defined on class scale because it must remain instanced for all its lenght private CommChannelBase ccb It ll be advisable to know the connection or disconnection status of communication channel for this purpose it ll be generated an event that can be linked with the statement ccb ConnectedEvent new CommChannelBase ConnectedEventHandler ccb ConnectedEvent Now it s possible ask the communication channel to run connection serial port opening ccb Connect 4 3 Communication manager The connection will happen receiving the event according to method ccb ConnectedEvent This method will set up if it hasn t been already done in other part of the program the object of class ELogCommManager Which performs the main function of the program that is the communication with the instrument the object will be set up through structure cp pcp previously set up or setting up a local structure as needed ProtocolCommunicationParameters pcp new ProtocolCommunicationParameters pcp SetElogDefaults ecm new ELogCommManager CommChannelBase sender pcp The object ecm includes s
11. second case the user needs to know the reason of failure so that he could solve the problem In this case the problem has to be checked through method linked to event CommSequenceTerminatedEventHandler In order to use the received data input following code in method linked to event DataReceivedEvent CISSCalcValues ccv CISSCalcValues e DataReceived RCCL User manual The received data are sent to method through an object coming from EventArgs which includes an object coming from CISSBaseData and that s dedicated to include the data transferred into specific communication with the instrument In case of instantaneous data of measures it s type CISSCalcValues this object has simple methods and properties for recovery of measures values Same system for use of other data transferred in ASCII mode by CISS protocol among these data there are the operation statistic data of the instrument cISSStatistics the registry data CISSRegistry and other data The processings of the measures stored in instrument s memory are transferred through binary code because they are potentially very big for this reason it s necessary take an other system The events stored in ecm object include also type BinDataReceivedEvent The method linked to this event is able to use the data received through binary way like processings At beginning it s necessary ask the library to run the communication with the instrument in order to receive the
12. t environment get onto it the reference to LSLRCCL dll library In the main window of application now you can add the instruction for reference to classes of objects which will be used in succession using LSI Lastem Lib2 Communications2 using LSI Lastem Lib2 CISS2 BaseServices using LSI Lastem Lib2 CISS2 ELogComm Data V2 using LSI Lastem Lib2 CISS2 ELogComm V2 4 2 Communication channel Library is able to use serial lines modem or TCP connections first of all specify it which communication channel it has to use This example is using serial connection To set up serial communication channel we can use a configuration structure type CommunicationParameters where are specified both use parameters of communication channel channel type bit rate serial port number etc and the parameters of communication protocol towards the instrument network address number of connection attempts timeout answer waiting etc If user want use different types of communication channels he needs to set up different values for items of this structure anyway the management of the communication will be the same for all type of used channel RCCL User manual CommunicationParameters cp new CommunicationParameters cp SetElogDefaults The statement SetElogDefaults Sets up all in one go all correct default parameters for use of the protocol towards E Log instrument For this reason you must set u