1.                                                                                                               Personal Computer  Pentium II  64 Mbyte RAM    figure 1   Development and testing conditions    Personal Computer   a Processor Pentium II   Operative System Microsoft Windows 98  RAM Memory 64Mbyte   1 Serial Port COM 1  9 pin connector  Screen 1024x768    Doo vo    Home made interface converter  IF in picture   a IF converter based on MC1488 MC1489  a External dual power  12V GND  12V    RTX Kenwood TS 440S AT   a Equipped with uwPD8251AFC e TC4040BP   a Parameters of ACCI serial port  Full Duplex  4800bps  Start Stop  Asynchronous   1  Start bit  8 Character bits  2 Stop bits  parity None          1   GND Signal Ground      2   TXD   Transmit Data  logically denied       3   RXD   Receive Data  logically denied       4   CTS   Transmit Enable      5   RTS   Receive Enable   ee ee    6   N C   Not connected      figure 2   ACC1 pin layout    In the above mentioned environment  I experienced no problems when the transceiver was  in RX  on the other hand I found very heavy RF feedbacks when the transceiver was in TX  mode  It is therefore mandatory to use a good quality interface converter    The program has been developed for the Kenwood model TS 440  However is not excluded  that it may work  even partially  with other transceivers receivers of the same brand     TS 440 remote Controller 4  User Manual release 1 0    e The program is based on the Kenwood proprietary
2.  serial protocol whose parameters are  described in the Kenwood IC 10 kit instruction manual    e The Personal Computer used in program development and testing was equipped with a  single serial port  named COM1  The program allows the user to select the desired  communication port among COM   2  3  4  However such features have not been tested     TS 440 remote Controller   5  User Manual release 1 0    2 The program  graphic interface and features    The graphic user interface  GUI  is shown below  For a world wide use  menus and commands are  in English language  Two user manual versions have been prepared  the present one   in English and  a further version in author   s mother tongue  Italian     w  15440 Remote controller iof ea  File About    VFO  C 1 MHz step  C 1 kHz step UP     100 Hz step DN  C 10Hz step      14 201 14    Hain  YFO B      7 200 000 4 5  A B    Function    FO    WFO      Monitor  Monitor window    ToRT   MOT   From ATs  FAOOOO  200000     Memory  bh UF     23 27 255 00  Goto      RIT    g On  0 94kHz    DM LIP  Reset RIT                     TORT  MROO23   To RTs  RTI     From AT  IF00014201140  094010 2301100    To RT  IF     oub  YF A    Others    ID   VOICE      RT I0    Lock Split IT  l Lock ON OFF   Split ON OFF M SIT ON OFF       M Lock Tx       figure 3   Graphic User Interface    The figure 3 shows the main panel  It is the only window of the program     2 1 Working criteria    Once launched the program  the working logic 1s     e PC   TS440 
3. 9  MHz   o The program will complete figures starting with 3  4  5  6  7  8  9 in the range 3  4  5   6  7  8  9 MHz   e Push the ENT key to load the frequency onto the TS 440     TS 440 remote Controller   13  User Manual release 1 0    
4. SDC sicnzalctusteaumrateenics ais atotaapeaiedea E ontdetaahvaiadins 1   DO  Bane Es gsc astecasamatteegatibacuacassiaacassanane E S 11  22 Frame MOn serra aean a A E Ea 11  DD  PIT KO erei aE E E NA 12  2213  Numere keypad sesser e a Ee a EESE 12  Figures  figure 1   Development and testing conditions               ccccccccsssesseececeecceaeseeseeceeeeceeaaseuseeeeeeeeeeaaaeseeeeeess 4  UEZ a COP pitt IA VOUL sexes ssscsaeestehaneeraaucu sie tek E a Aa 4  eure  v  Graphie User Iter aCeee a E A A T E E 6  Houi Ade Frame UNC UN OM  it eects sinc cick va ta ence eect eh lal E Deda 7  HST  Sail  ch aetna ren eer er A T eye tier Teer tne rarer rere aetan rer rere See 8  TPC era Trane  VLOG r cen arate uaade a wnciag ination anna aden nie huatusa aera Bindi wasted 9  Heare T  Frame  Memo aeea Ree eee eT Te 9  Meure Se Trame    RIU decabeaiediesndonsncreied aeemacnsenavonelaietaie kt E ventana east licedaan et N uas 10  Hone S  Framo OS saaacaezadelrencaintetsstgsctaniantondausaihe E a a yes ecyuanaunsnsaededasees 10  Maure lOs Frame OC ke onna a E ce are iia 10  Heure  Frame Spi eee i E EEEN 11  Heure P  Frame AL serra e E a Ee 11  Mue D  Fame Montor area a Guus aeeieataneaeels 11  Mere 14   Example Ol exc hanee d So Sn a E S 11  M SPET E o a E a STE ea TE 12  Heure LOS Numere keypad seice TEA enolate edeoaeid 12    TS 440 remote Controller    User Manual release 1 0    1 Introduction    TS440 Remote Controller is a software designed to remotely control the Kenwood TS 440 by  mean
5. TS440 Remote Controller  User manual    TS 440 remote Controller  User Manual release 1 0    Table of Contents    Uh EP OCU CTO scence cates ta naa taxetateadinte cuctetat cates ausdeteet oie ddarnscectefaceetas uns A EA 3  1 1 Scope of the program and working criteria           sssssseooeeessssssseeeeeeresssssseeeerressssssseerressssssssees 3    Zam E E a E E EE A A I A E E A E E E T E T 3  1 3 Hardy are Tegu e Ne MIS e E r E E 3  1 4 Working and development environment             s  seeesssssssssseetersssssssseeerssssssssceerssssssseeeerrsssss 4  2 The program  graphic interface and Teatures ss  cccccccaedics ssssvaeia e a 6  2 1 NY OF IS CLUS aos 2tsaah siienesitna cinco a lnsacaauamsandast a 6  2 2    Menus  Controls and Groups of Controls             eesssssseoeeesssssssseerrssssssssseersssssssseeeersssssssseereeo 7  22 1 INTC TMUIS 3 5 caeaa noae a teres tte geen a a ese tenes  7  222 Fie UMC LOIN  osceann O E taniniansaae vecnetansoerts 7  22 3 erate  Vib Osc ica aaaataiiahaeasranerecerca sana sands ian caeeanerean canarmcerscs Minataeeesaceenaeaernemeetses 8  2 2 4 Frame Mode setsxscesctlavalcaraxence cede E T texi bord Uaealaaranensededa tne nde  9  225 Frame MEMO serosa ciatvazeesterd vetsacsdteste R 9  2 2 6 Poe RT rene ere ey ernment E ny reg erin re oe eer are tre ener 10  2     gb eH ak   1 01  Hs gene ne Ts Cone mvgmne ot atten nS TN Cen ah Sel ae RST eC ene er tT Crna ee et 10  2 2 8  g  e218 0 eval B06  EE nop E T P A errr T oe eae ere ene ee 10  229 Fraime 
6. derstanding of the  proprietary serial communication protocol  commands parameters      2 2 12 PTT key       ON AIR    F Lock Tx    figure 15   PTT key    The PTT key is used to put the transceiver in transmission  The PTT software key has to be pushed  with the left key of the mouse     PUSHING the left key of the mouse   e The user puts the TS 440 in transmission mode   e The    ON AIR    label lights     RELEASING the left key of the mouse   e The user puts the TS 440 in receiving mode   e The    ON AIR    turns off     A Check Box    Lock TX    prevents from an accidental pressing of the PTT key  The Check Box is  set to    ON    at the program launch     2 2 13 Numeric keypad       figure 16   Numeric keypad      The Kenwood proprietary communication protocol requires that all commands strings ends with           TS 440 remote Controller 12  User Manual release 1 0    The numeric keypad is used to set on the main VFO the desired frequency  The keypad is enabled  only when the TS 440 is in VFO mode  please see 2 2 3   To use the keypad correctly     e Push the SET key  The main VFO panel empties   e Insert the desired frequency by means of software  O to 9  keys  Please note that   a Inserting    0    as first digit does not have any effect   a It is possible to input few digits only  letting the program to complete the frequency  value  adding the needed number of zeros  Please note that   o The program will complete figures starting with 1 or 2 in the range 10 19 e 20 2
7. g software button    UP     or    DN      the main VFO frequency will be incremented  or  decremented  of 100Hz     TS 440 remote Controller   8  User Manual release 1 0    2 2 4 Frame    Mode          figure 6   Frame  Mode     The frame    Mode    contains a set of option buttons to select the desired mode  Please note that this  frame may be affected by the use of other buttons commands of the program  For instance   switching from VFO A to VFO B  please see A B button in section 2 2 3  shall change the current  mode if VFO B  the new main VFO  has a different mode from VFO A     2 2 5 Frame    Memory       Memory  Bie UF     23  27 255 00  Go ta      figure 7   Frame  Memory         The frame    Memory    contains     e  lt A panel indicating the current memory channel on the TS 440  The panel is writing  disabled    e A panel indicating the frequency of the current channel on the TS 440  The panel is writing  disabled    e Two DN UP buttons to increment  UP  or decrement  DN  the memory channel    e A Combo Box with a 00 99 list to have direct access to the desired channel memory   avoiding the multiple use of UP DN buttons     When the user asks for an empty memory  by means of the DN UP keys or the Combo box tool  a  warning windows is proposed  Empty memories cannot be accessed  If the program is launched  while the TS 440 is set in Memory Mode and the current memory channel is empty  the relevant  memory frequency panel is set to 0 00  The memory channel panel remain
8. link enabling  first of all it is needed to enable the desired serial  communication port  Please refer to menu File  After the port has been open  the program  asks the transceiver for all needed parameters to set up the panel  In a second  all needed  parameters are loaded and the user may begin to use the program    e Regular working   Once linked  it is possible to perform a large set of commands onto the  transceiver  without touch it  Please refer to section 2 2 for a detailed view of possible  features    e Link closing  After the regular use  it is suggested to close the serial link with the TS 440    e Exit  The menu File Exit exits the program  Before exiting  the software automatically  closes the serial communication port  if open     TS 440 remote Controller   6  User Manual release 1 0    2 2 Menus  Controls and Groups of Controls    Please refer to the following sections for a detailed explanation of menus  controls and groups of  controls onto the main program panel     2 2 1 Menus    The menu File allows the following actions     e Open COM 1  Enables the serial port COM 1 to connect with the TS 440 and loads from  the transceiver the needed parameters to set up the panel    e Open COM 2  Enables the serial port COM 2 to connect with the TS 440 and loads from  the transceiver the needed parameters to set up the panel    e Open COM 3  Enables the serial port COM 3 to connect with the TS 440 and loads from  the transceiver the needed parameters to set up the pa
9. me    Lock       Lack  T Lock ON OFF    figure 10   Frame  Lock     The frame    Lock    contains a Check Box to be used to enable or disable the    frequency lock     function  This software button has the same function of the LOCK key on the front panel of the TS   440  This Check Box is automatically set up at the program launch on the basis of the current status  on the TS 440     TS 440 remote Controller   10  User Manual release 1 0    2 2 9 Frame    Split       Split  Split ON OFF    figure 11   Frame  Split     The frame    Split    contains a Check Box to be used to enable or disable the    Split    function  This  software button has the same function of the SPLIT key on the front panel of the TS 440  This    Check Box is automatically set up at the program launch on the basis of the current status on the  TS 440     2 2 10 Frame    XIT       xT   IT ON OFF    figure 12   Frame  XIT     The frame    XIT    contains a Check Box to be used to enable or disable the    XIT    function  This  software button has the same function of the XIT key on the front panel of the TS 440  This Check  Box is automatically set up at the program launch on the basis of the current status on the TS 440     2 2 11 Frame    Monitor       The frame    Monitor    contains a window reporting command strings coming from  presented with  the label From RTX  and going to  presented with the label To RTX  the transceiver  The scope of  the windows is to put the user in the condition to keep an e
10. nel    e Open COM 4  Enables the serial port COM 4 to connect with the TS 440 and loads from  the transceiver the needed parameters to set up the panel    e Close Serial Port  Disables the currently used serial port    e Exit  Exits the program  If the serial port currently used for the link to the transceiver is still  open  it closes it     The menu About shows an    info    window  If the users attempts to open a serial port already open   a warning message is shown     2 2 2 Frame    Function          figure 4   Frame  Function     The frame    Function    contains a button VFO M to be used to switch the status of the transceiver  from the mode VFO to the mode MEMORY and vice versa  The label immediately above the  button shows the current status of the TS 440  When the transceiver is in VFO mode  the frame  Memory is disabled  see 2 2 5   On the other hand  when the transceiver is in Memory Mode the  frame VFO  see 2 2 3  is disabled  as well as further features  e g  the possibility to input a desired  frequency by means of the numeric keypad  see 2 2 13       TS 440 remote Controller   7  User Manual release 1 0    2 2 0 Frame    VFO       VFO  C 1 MHz step  C 1 kHz step UP    100 Hz step DN  C 10 Hz step      14 201 14       Hain  YFO B      7 200 000 A B  A B    oub  YFO A    figure 5   Frame  VFO   The Frame    VFO    includes     e Four option buttons to select the desired frequency increment  or decrement  step by  means of UP DN buttons  see bullet below     e Tw
11. o DN UP buttons to increment  UP  or decrement  DN  the current frequency shown on  the main VFO panel  VFO A or VFO B     e A main VFO panel indicating the frequency of the VFO currently set up as main VFO on  the Kenwood TS 440  The label immediately below the main panel shows which VFO is  currently set as main VFO on the transceiver  It is not possible to input digits in the panel   the panel is writing disabled   but the user may input the desired frequency by means of the  numeric keypad  2 2 13     e A secondary panel indicating the frequency of the VFO currently set up as SUB VFO on  the Kenwood TS 440  The label immediately below the secondary panel shows which VFO  is currently set as SUB VFO on the transceiver  Please note that the TS 440 does not  indicate the SUB frequency on its embedded display  It 1s not possible to input digits in the  secondary panel  the panel is writing disabled     e An A B button to switch the status of the TS 440 relating to Main Sub VFO  This software  button has the same function of the A B key on the front panel of the TS 440    e An A B button to make the SUB VFO frequency equal to the main one  This software  button has the same function of the A B key on the front panel of the TS 440     The sample above  figure 5  shows     e On the TS 440  the main VFO is VFO B  The transceiver   s display indicates 14 201 14  MHz     e On the TS 440  the SUB VFO is VFO A  There are no indications on SUB VFO frequency  on the TS 440     e Pushin
12. own risk  The author cannot guarantee the  correctness of the program and cannot be kept responsible for any kind of problem or loss or any  kind of damages to user   s devices     1 3 Hardware requirements    The communication between Personal Computer and TS 440 needs     e The installation of a Kenwood kit named IC 10  two integrated circuits uPD8251AFC and  TC4040BP  needed to enable the serial data transmission through the ACC1 port on the  rear panel of the TS 440  It is possible to find those ICs on the market without buying the  IC 10 kit  and install them following directions included in the User Guide of the Kenwood  TS 440 transceiver    e The use of a RS232 TTL converter to be installed between the serial COM of the Personal  Computer and the serial ACC1 on the TS 440  Such device translates RS232 logical levels  used by the serial port of the personal Computer in TTL logical levels  understood by the  ACC port and vice versa  Kenwood puts on the market a product called IF232C  however it  is possible to find a scheme to home made such device using  for instance  a MAX232 or a  couple of MC1488 MC1489  Please note that it is suggested to use opto electronic devices    TS 440 remote Controller   3  User Manual release 1 0    for the translation  in order to physically separate the PC from the RTX  with the aim of  avoiding problems of RF feedbacks     1 4 Working and development environment  Please refer to the following picture for working environment     Notes   
13. s empty     In the sample pictures above  figure 3 and figure 7  the TS 440 is set on VFO mode  For this reason  the Memory panel is disabled  However the current channel memory  23  and the relevant  frequency  27 255 00 khz  are shown  However there is no indication about the channel memory  mode     TS 440 remote Controller   9  User Manual release 1 0    2 2 6 Frame    RIT       RIT    g On  0 94kHz       DM LIP  Reset RIT    figure 8   Frame  RIT     The frame    RIT    contains     e A Check Box named    ON    by means of which the user may enable or disable the RIT  function on the transceiver    e A panel indicating the current RIT frequency in kHz on the TS 440  The panel is writing  disabled    e Two DN UP buttons to increment  UP  or decrement  DN  the RIT frequency  The  increment  decrement  step is fixed and set to 0 01 kHz    e A RESET button to be used to cancel  set to 0  the RIT frequency     Others  ID   VOICE    RTs IO    figure 9   Frame  Others     2 2 7 Frame    Others       The frame Others contains     e An ID button to ask the radio for an ID code  The string coming back from the connected  device is interpreted and the relevant label  immediately below the key is set to    TS 440    or     R 5000     depending on the device being asked  No tests have been made with different  Kenwood equipment    e A VOICE button to ask for voice confirmation  This software button has the same  function of the VOICE key on the front panel of the TS 440     2 2 8 Fra
14. s of a Personal Computer  This user manual explains working criteria of the program     1 1 Scope of the program and working criteria    It is important to underline the    philosophy    behind the program  The main scope was the  implementation of a robust and reliable tool to manage the transceiver  without the physical  presence close to it  A typical application could be the installation of the transceiver and a dedicated  PC in a room immediately under the roof  with the possibility to fully control it from a first floor  room     For this reason the program has been designed in order to make it as robust and reliable as possible   after have sent any command to the transceiver  the program typically asks the TS 440 in order to  have confirmation about the real execution of the command just sent  Moreover a monitor window  has been included  in order to keep an eye on strings coming from the transceiver and sent from the  Personal Computer     There are no advanced tool for memory channel management   e g  the possibility to keep stored on  the HD a set of memory banks to be loaded onto the 100 memories bank in the TS 440      1 2 Disclaimer    The TS440 Remote Controller program has been designed and implemented for amateur purposes  only  It is distributed for free  with the inclusion of the source code  The author thanks in advance  any people suggesting or proposing any fix or any improvement in general     It is understood that users will use this software at their 
15. ye on the strings exchanged between the  Personal Computer and the Transceiver     Monitor Monitor  Monitor Wingo Monitor window    To RTs  MOT        To RTX  RTI     From AT  EARE  094010 2301100    To RT  IF     figure 13     Frame  Monitor  figure 14     Example of exchanged strings    The strings are intercepted on the serial port and are reported on the window  starting from above   Old strings scroll below  Please refer to figure 14 for a typical program start up sequence  In this  picture  highlighted commands  beginning from below  older commands  to above  newer  commands   are briefly explained below     TS 440 remote Controller   11  User Manual release 1 0    1  The PC asks the TS 440 sending the    IF     Information   command  The TS 440 answers  back with a complex string with a lot of information  including the main VFO frequency in  Hz  00014201140   the RIT frequency in Hz   0940  and several other info    2  The PC asks the TS 440 sending the    MR     Memory Read  command attaching several  parameters including the channel memori ID  23   The TS 440 answers back with a string  containing the channel 23 frequency in Hz  00027255000   the current channel mode  5  stands for AM  and other info    3  The PC asks the TS 440 sending the    FA     VFO A  command  In this case the VFO A is set  as SUB  The TS 440 answers back with a string containing the VFO A frequency in Hz   00007200000      Please refer to the Kenwood IC 10 Instruction Manual to have a deep un
    