User Manual XH-W1301
Contents
1. P8 restore the factory settings Some man made causes lead to confusion in the internal settings of the thermostat to set one by one is very time consuming can use this function to restore the factory settings the specific method SET 5 seconds to display PO switch to P8 SET is set to on or off and on to restore the factory settings off no action finished press SET to return long press SET or 10 seconds the bell no key controller automatically restore the factory settings parameters in the table below xX gt lt mD Z lt gt M L gt L Code Description setting range Factory setting PO Cooling Heating C H C P1 Hysteresis setting 0 5 15 2 P2 Highest setting upper limit 110 110 P3 Lowest setting upper limit 50 50 P4 Temperature correction 7 7 C 0 P5 Delay start time 0 10 Minutes 0 P6 Buzzer ON OFF ON Connection Diagram P7 High temperature alarm 0 110 C OFF ettings ON OFF OFF P8 Restore factog 7 7 i Led indicate cooling or heating Gal K m LI i Set Switch Switch Switch a ae a eo m prem Pen Sm ee ale a Fimo ee Waterproof sensor a gt fe Power Supply 12v DC AC 12V or 12V AC 12V DC Out its not a common or open contact positief trigger dont put power suply to KO or K1
2. User Manual XH W1301 Connect the power supply and equipment to supply to the controller is displayed for the measurement of temperature Time you press the SET button the display temperature flashing Press to set the desired temperature hold down the quickly lift press SET to confirm the setting is complete return the controller to set the auto relay off The thermostat output 10A relay meet a variety of high power load connected to the control circuit power supply to the thermostat the display shows the ambient temperature Lights digital control and buzzer status LED flashes to indicate cooling or heating start up delay Always the relay is closed Digital tube LL sensor open circuit please follow the instructions to connect the sensor HH Forces beyond the measurement range thermostat off the relay high temperature alarm Buzzer LL HH digital display the buzzer beep beep beep beep sound Parameter Function Description Long press SET 5 seconds to enter the main menu settings return switch PO P8 long press the SET or 10 seconds of no key activity controller automatically recognized PO refrigeration heating mode Long press SET 5 seconds to display a PO press SEFoperating mode heating mode Switch H C cooling mode and press the SET returns long press SET or 10 seconds of no key activity controller automatically recognized complete Cooling mode When the temperature measurements 2 temper
3. ature set point cooling relay pull the chiller start when the temperature measurement value lt temperature set point hysteresis refrigeration relay is switched off cooling off Heating mode When the temperature measurement value lt temperature set point the heating relay pull the heater starts when the temperature measurements 2 temperature set point hysteresis heating relay is switched off the heater is turned off Wd P1 hysteresis setting Long press SET 5 seconds PO Switch to P1 press SET to set back to the difference Press to set the hysteresis 0 5 15 finished press SET to return long press SET or 10 seconds no key the action controller automatically confirm completion Cooling mode When the measured temperature 2 set value the relay cooling starts when the temperature measurement value lt settings back to the difference the relay is switched off the cooling is turned off such as the environment is 30 C setting is 25 C hysteresis is set to 2 C after power relay is closed refrigeration to start the relay off when cooling to 23 C cooler Close this time due to the cooler has been disconnected the temperature began to rise when the pick up to the set value 25 C the relay is closed refrigeration start again and so forth loop to control the temperature not higher than 25 C Heating mode When the temperature measurement value lt settings relay heater start when the temperature measure
4. e of 0 10 finished press SET to return long or 10 seconds the keystrokes controller automatically confirm the completion of The first power cooling mode If the current temperature 2 settings the cooler will not start immediately after refrigeration you need to run the set delay time start xX gt lt mD Z lt gt M L gt lt Heating mode power is first applied if this temperature lt set value the heater does not immediately start the heating the need to run the set delay time after start Refrigeration or heater adjacent two starts downtime between more than delay the start time settings refrigeration immediately start Shut down for the first time between the start of the refrigeration or heater adjacent two less than the delay start time the need to run to completion set refrigeration equipment to start the delayed start time setting and start again The delay time from shutdown instantly Such as refrigeration state set a delay of 5 minutes start up delay after boot refrigeration refrigeration When you reach the desired temperature refrigeration stop then start the timer after 5 minutes open the next time the cooler completion of the start timing immediately unfinished timing to wait for the end of the timing to work delay LED blinks Delay start is set to 0 is equal to the turn off delay function The P6 key tone switch Long press SET 5 seconds PO switch to P6 time the SET is turn
5. ed on key sound press the Set the on off tinished press SETto return ong press SEFor 10 seconds of no key activity control automatically confirm completion Buzzer switch points on off is set to on key action with the key issue drops sound set to off to turn off the buzzer no voice P7 high temperature alarm SET 5 seconds to display PO switch to PY press SET to display the on off set to off to turn off the sub function is set to on press SET to set the temperature of the high temperature alarm point press the 7 setting O 110 after the completion of time the SET returns long press SET or 10 seconds of no key activity controller automatically confirm the completion of the High temperature alarm setting range is 0 110 or closed off times to reach rapid buzzer beeps high temperature alarm and forced off the relay For example we want to give a liquid or space heating to 40 degrees set 80 degrees as dangerous temperature inthe course of their work force majeure due to external causes the temperature is above 80 degrees the temperature danger the start temperature alarm relays to disconnect the buzzer shortness alarm a timely reminder of the staff to take appropriate measures to recoup their losses Alarm temperature can be set according to actual needs if you do not want the temperature is set to off note that when returns to normal temperature automatic discharge temperature alarm thermostat work properly
6. ment value 2 set value hysteresis value the relay is switched off the heater is turned off xX gt lt mD Z lt gt M L gt L Such as the environment of 10 C set value of 25 C hysteresis is set to 2 C after power relay is closed heater starts when heated to 27 C the relay is switched off the heater off this time due to heater has been disconnected temperature began to drop the moment down to the set value of 25 C relay closes when the heater is started again and so forth loop control temperature not lower than 25 C P2 highest temperature setting limit To avoid the misuse of others led to the set temperature is too high risk maximum cap on the thermostat limit the maximum temperature set point temperature control setting range SET 5 seconds to display PO switch to P2 SET the maximum Set the maximum set temperature and the maximum is 110 finished press SET to return long press SET or 10seconds keystrokes controller automatically confirm completion For example setting can only be set up to 60 C To temperature set point higher temperatures expand the scope of you need to adjust the limit values for the 60 temperature set point P3 is the lowest temperature setting limit To avoid others to misuse the temperature is too low occurrence of ice block the thermostat lowest setting upper and lower limits defining the minimum temperature set point temperature control
7. setting range SET 5 seconds to display PO Switch to P3 press SE Eto set the minimum lower limit Press to set the minimum set temperature the minimum value of 50 finished press SET to return long press SET or 10 seconds of no key activity controller automatically confirm completion For example 2 temperature set point minimum can only be set to 2 C if you want the temperature set point lower temperature range to expand you need to adjust the settings of the lower limit P4 temperature correction When measuring temperature and standard temperature deviation with special needs or because the user hardware you can use this feature correction the corrected temperature temperature before correction correction value of the effective range of 7 0 to 7 0 Long press SET 5 seconds to display PO Switch to P4 correction time the SET positive Set the school finished press SET to return to long press the SET or 10 seconds of no key activity controller automatically confirm completion For example the normal display is 25 degrees temperature correction display is 0 to 25 degrees temperature is corrected to 1 5 to 26 5 degrees temperature correction 1 5 23 5 P5 delayed start time minutes Refrigeration or heater delay of need on delay functions to protect the life of the equipment Long press SET 5 seconds PO switch to P5 time the SET set delay start time in minutes press the SET Set a scal