        USER MANUAL USK1024 ACCES CONTROL DEVICE
         Contents
1. USER MANUAL  USK1024 ACCES CONTROL DEVICE       Version I   26 07 2012    General information    The device is dedicated to work with maximum 1024 Maxim Touch Memory DS19xx iButton  keys  The key 1s a hermetically closed metal tablet with diameter of 17 mm and 6 mm high  with  a Integrated Circuit inside  Each key has it   s unique code assigned   The number of possible  combinations is 10 to the power 14       Button keys have a high mechanical durability and a high resistance for EM influence  The  device is placed inside the readers    case  The reader 1s equipped with a LED indicator  which  shows the state of the device     The concept of key registration is to allow a single key to work with any number of controllers   The programmed data of keys and the configuration mode of the device are stored In the  EEPROM   therefore a lack of power supply has no affect on the stored data     Application    USK 1024 15 mainly dedicated to anti theft intercommunication  access control system   steering  for doors  EM hitch  and other receivers    where load current does not exceed 2 Ampere  USK  1024 can be used in devices exposed to vibrations  if the loss of the connection between the  reader and key is less then Is  the device will still continue to work in chosen mode     State of the device  ON OFF  is changed by touching the device with a previously programmed  DS1990 Dallas iButton key  By eliminating keyboards and RF transmission a high degree of  confidentiality was obtai
2. for 1 s  The device is ready to work after a RED  LED light appears     Switching to Bistable mode  Touch and hold the reader with a MASTER key for longer then 30s   The change of the MODE    is signalised by GREEN LED light appearing for 1 s  After removing the MASTER key the  device 1s ready to work after a RED LED light appears     Cables     WHITE  power supply 9 30 V DC  BROWN   Earth common  GND   GREEN     Open Collector  drain  output    Example   Electrical Hitch    USK 1024  DRIVER       ea  Power Supply 9 30 Y DC    Photos of the device    O         Head of the driver Side if the driver    Demiurg  W Wojtasik  R Wronska Wojtasik  T Wojtasik s c        93 479 t  dz  ul  Pustynna 66 www demiurg pl  NIP  727 10 58 736  REGON 471255347 www readers com pl  tel  fax  48 42 636 70 70 demiurg demiurg pl    
3. ned     Technical data     ePower Supply  9   30V DC   e Max power supply pulse factor   5    e Max  electricity consumption   30mA   eOC output  maximum load 2 A   e Working temperature  40    70  C   eAir Humidity  up to 80    e Work environment   residential  commercial   lightly industrial  eDimensions     e diameter of the tread   012mm    e height of the tread   15mm    e diameter of the base of the reader      12mm   e high of the reader  from the base up to the ring  14 3mm  e Maximum 1024 keys   e Maximum cable length   200cm   eBuild in protection from polarity change    eLED indicator states   e3 possible working states    Storage   The device can be stored in a place with air humidity up to 80  and temperatures in rage from    45  C up to  80  C     Cooperating devices   DS1990 Dallas iButton keys    Assembly     In order to assemble to device      Unscrew the nut from the thread of the reader   Take of the washer   Shift the wires through the hole in the case    Shift the wires through the washer and the nut  Install the device by tightening the nut   Install the reader     Of ee e E    First Activation    The device has no programmed keys as default  Define two MASTER keys before first  activation  If no MASTER key is remembered the device after powering the reader is ready to  program  Yellow LED indicates the programming state  Define two keys in order to input the  reader into programming state  Pulsating green LED light confirms memorising the keys   after  
4. or 20 s  2  The LED indicator starts to pulsate in a sequence GREEN YELLOW   GREEN RED  one  flash of GREEN for 1 s  The sequence ends with a continuous YELLOW light   3  Erasing the EEPROM 1s possible by holding the MASTER key inside the reader  The  light will change from continuous YELLOW to continuous RED  4  Take off the MASTER key  All the MASTER keys will be deleted in this process as well      go to FIRST ACTIVATION    Configuration of the Device    USK 1024 can work in three modes  e with programmable by the user time intervals  from 2 to 30 seconds    e bistable  e Touch and hold mode  The device has three programming modes   e adding   deleting keys  e work mode change  e restore default settings    Changing the MODES 1s available at any time by   1  Touch and hold one of the MASTER keys until the LED indicator starts to pulsate in a  0 5s internals of YELLOW and GREEN light   2  Remove the MASTER key  The device returns to PROGRAMMING mode  The LED  indicator shows YELLOW light     Switching to TAH mode   Touch the reader with a MASTER key  for a short period of time   The change of the MODE is    signalised by GREEN LED light appearing for 1 s  The device is ready to work after a RED  LED light appears     Switching to Monostable mode  Touch and hold the reader with a MASTER key for a period of time that is to be assigned to the    monostable mode  The programmed time can be from 2s up to 30s     The change of the MODE  is signalised by GREEN LED light appearing 
5. which the system resets into the programming state allowing more keys to be memorised   Pulsating yellow LED indicates the device is expecting another key  First two memorised keys  are MASTER keys  All others are SLAVE keys     WARNING    MASTER keys are not functional for normal work  Only the SLAVE keys are able to  perform inputted work mode    In order to simplify driver programming  it is advised that the MASTER keys are TAH    type     Adding and deleting keys    A SLAVE key can be added at any time  In order to register a key follow the steps bellow    1  Touch the reader with a MASTER key for a time no longer then Is    2  Yellow LED light indicates programming mode   3  To register a key touch the reader with a new key   its data will be remembered in EEPROM   It is signalised by double pulse green LED light  The device switches to programming mode     it  is now possible to register or delete keys    OR   To delete a key     touch the already assigned SLAVE key  its data will be removed from the  EEPROM  A red LED light will switch on for 1s  The device switches to the programming mode      it is now possible to register or delete keys  WARNING   It is not possible to delete a  MASTER key following these steps    4  To return to NORMAL mode touch the reader with a MASTER key for a second time    One key can be programmed into an infinite number of devices     Restore default settings    In order to restore default settings    1  Touch the reader with a MASTER key f
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Day Day Up  User Manual For Portable Biometric Compact Safe  中央老人福祉センター  Manual del usuario - AG Neovo Service Website  Bedienungsanleitung  Hampton Bay AG804-LN Instructions / Assembly  Lincoln Electric PRECISION TIG 275 User's Manual  On Networks N300 Wireless ADSL2 + Modem Router N300RM  HORIZONS User Manual Version 3.12 (January 4, 2005)  Notice de montage (version pdf > 500 Ko)    Copyright © All rights reserved. 